Download Siemens SINUMERIK 802D sl Specifications

Transcript
06/2007
Overview of alarms
Cycle alarms
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use a smaller tool.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61278
Channel %1 block %2: If tool angle is larger than 90°, both tool diameters
must be equal
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For tool angles larger than 90°, the two tool diameters must be identical.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the tool angle or the tool diameters.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61279
Channel %1 block %2: If tool angle equals 90°, both tool diameters must
be equal
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For tool angles equal to 90°, the two tool diameters must be identical.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the tool angle or the tool diameters.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61280
Channel %1 Block %2: Mirroring in WO %4 missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If the program starts with a counterspindle movement, a work offset with mirroring will have to be
selected.
Alarm triggered by following cycle: F_SUB_SP
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select the mirroring for the work offset used.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61281
Channel %1 block %2: starting point of machining outside retraction
planes
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The starting point of machining is outside the retraction planes.
Alarm triggered by following cycle: F_SP_RP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adjust the retraction planes.
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
2-303