Download AUSTRALIAN MONITOR XRS Series Specifications
Transcript
SERVICE INFORMATION XRS12P POWERED LOUDSPEAKER CONTENTS: OPERATION MANUAL SCHEMATIC DIAGRAM Australian Monitor 1 Clyde Street, Silverwater NSW 2128 Australia +61 2 9647 1411 www.australianmonitor.com.au XRS SERIES POWERED AND PASSIVE LOUDSPEAKERS INSTALLATION AND OPERATION MANUAL IMPORTANT SAFETY INFORMATION 1. Save the carton and packing material even if the equipment has arrived in good condition. Should you ever need to ship the unit, use only the original factory packing. 2. Read all documentation before operating your equipment. Retain all documentation for future reference. 3. Follow all instructions printed on unit chassis for proper operation. 4. Do not spill water or other liquids into or on the unit, or operate the unit while standing in liquid. 5. Make sure power outlets conform to the power requirements listed on the back of the unit. 6. Do not use the unit if the electrical power cord is frayed or broken. The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance. 7. 8. 9. Always operate the unit with the AC ground wire connected to the electrical system ground. Precautions should be taken so that the means of grounding of a piece of equipment is not defeated. Mains voltage must be correct and the same as that printed on the rear of the unit. Damage caused by connection to improper AC voltage is not covered by any warranty. Have gain controls on amplifiers turned down during power-up to prevent speaker damage if there are high signal levels at the inputs. 10 Power down and disconnect units from mains voltage before making connections. 13. Do not block fan intake or exhaust ports. Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit, such as a bed, rug, weathersheet, carpet, or completely enclosed rack. If the unit is used in an extremely dusty or smoky environment, the unit should be periodically “blown free” of foreign matter. 14. Do not remove the cover. Removing the cover will expose you to potentially dangerous voltages. There are no user serviceable parts inside. 15. Do not drive the inputs with a signal level greater than that required to drive equipment to full output. 16. Do not connect the inputs / outputs of amplifiers or consoles to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or console is turned on or off. 17. Do not run the output of any amplifier channel back into another channel’s input. Do not parallel- or series-connect an amplifier output with any other amplifier output. Australian Monitor is not responsible for damage to loudspeakers for any reason. 18. Do not ground any “hot” (red) terminal. Never connect a “hot” (red) output to ground or to another “hot” (red) output! 19. Non-use periods: the power cord of equipment should be unplugged from the outlet when left unused for a long period of time. 20. Service Information Equipment should be serviced by qualified service personnel when: A. The power supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the equipment 11. Never hold a power switch in the “ON” position if it won’t stay there itself! C. The equipment has been exposed to rain 12. Do not use the unit near stoves, heat registers, radiators, or other heat producing devices. D. The equipment does not appear to operate normally, or exhibits a marked change in performance E. The equipment has been dropped, or the enclosure damaged. THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL INTRODUCTION AND CONTENTS Building on the reliability and sonic quality of the very popular XR speaker series, Australian Monitor brings you the AM Pro XRS two way injection moulded speaker enclosures with more features and new aesthetic to suit both live sound reinforcement and permanent installation. From Front of House to fold back, the dance floor to background fill, the XRS series with both passive and powered options are designed with flexibility and performance in mind. The AM Pro XRS range includes 8”, 10” and 12” models all with high quality compression drivers and represent a significant advancement in injection moulded box design while maintaining excellent audio quality and great value for money. INTRODUCTION 3 FRONT AND REAR PASSIVE PANEL 4 REAR POWERED PANEL 5 SPECIFICATIONS 6 AUS, EUR, USA REV A 24th Nov 2008 CAUTION This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER SERVICEABLE PARTS INSIDE, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol is intended to alert the user to the presence of important operational and maintenance (servicing) instructions in the literature accompanying the appliance. Caution: WARNING! To prevent electric shock do not use this (polarised) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure. To prevent electric shock, match wide blade of plug to wide slot, fully insert. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. XRS SERIES INSTALLATION AND OPERATION MANUAL PAGE 3 FRONT AND REAR PANEL PASSIVE VERSION 1 2 1 High Frequecy Driver 1 XRS8 shown here 1 Speaker Input Horn loaded compression driver. Directivity 90deg x 90deg. Passive crossover in the XRS8/10/12. XRS8/XRS8P 1.5” XRS10/XRS10P 1.5” XRS12/XRS12P 2” The input connector is a 4 pole speakon compatible connector. Pins 1+ and 1- are wired to the +ve and -ve respectively of the speaker. The XRS10 and XRS12 have 2 connectors. They are wired in parallel so either connector can be used as an input, the other as a loop through. Active crossover and power amp in XRS8P/10P/12P. XRS8P 50W XRS10P 50W XRS12P 100W Accessories: XRS8/XRS8P XR8PMA Pole mount adapter XR8UMB Universal mounting bracket 2 Low Frequency Woofer Driver sizes: XRS8/XRS8P 8” XRS10/XRS10P 10” XRS12/XRS12P 12” Active crossover and power amp in XRS8P/10P/12P. XRS8P 100W XRS10P 100W XRS12P 300W Note that the XRS8 ships as a pair. PAGE 4 XRS10/XRS10P XR10CVR Heavy duty cover AMISLSB1 Wall mount brackets ATC303 Tripod speaker stand ATC304 Heavy duty tripod speaker stand ATC305 Winch up speaker stand XR10-12UB Universal bracket XRS12/XRS12P XR12CVR Heavy duty cover AMISLSB1 Wall mount brackets ATC303 Tripod speaker stand ATC304 Heavy duty tripod speaker stand ATC305 Winch up speaker stand XR10-12UB Universal bracket XRS SERIES INSTALLATION AND OPERATION MANUAL REAR PANEL POWERED VERSION 7 10 2 8 11 4 9 12 6 1 MIC IN This is a balanced XLR microphone input. 10 Line LEVEL This controls the level of the LINE input. (3) 2 Mic SIGNAL 11 Line BASS This is a green LED signal present indicator for the Mic input. It indicates signal present on the input and is not affected by the level control. 1 3 5 3 LINE IN This is a balanced XLR line level input. 4 Line SIGNAL This is a green LED signal present indicator for the Line input. It indicates signal present on the input and is not affected by the level control. 5 LINE OUT The LINE OUT is on an XLR connector. This output can be connected to the LINE IN on another XRS Powered speaker to expand the system. 6 Output CLIP This is a red LED clip indicator for the mixed mic and line audio signal. Some flashing of red is acceptable on program transients. Continuous flashing of red could be placing undue stress on the speaker and will sound distorted. Turn down the input level until the clip LED is no longer lit. 7 Mic LEVEL 15 13 14 This controls the level of the MIC input (1). 8 Mic BASS This is the bass control for the MIC input (1). There is 12dB of cut and boost at 100Hz. This EQ is the shelving type. 9 Mic TREBLE This is the treble control for the MIC input (1). There is 10dB of cut and boost at 10kHz. This EQ is the shelving type. XRS SERIES INSTALLATION AND OPERATION MANUAL This is the bass control for the LINE input (3). There is 12dB of cut and boost at 100Hz. This EQ is the shelving type. 12 Line TREBLE This is the treble control for the LINE input (3). There is 10dB of cut and boost at 10kHz. This EQ is the shelving type. 13 Power Switch This switch turns the power on or off to the unit. 14 IEC Mains Input Socket This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, (provided). The fuse draw contains the mains fuse and a spare. The mains fuse is a time lag (slow blow) HRC 20mm x 5mm ceramic or glass type fuse. XRS8P XRS10P XRS12P 2.5A 2.5A 5.0A IMPORTANT: Always replace the fuse with one of the same value and type. NOTE: Always disconnect power to the amplifier before replacing fuses. 15 Voltage Select Switch This switch is used to select the mains voltage for your region. Select either 230V or 115V. IMPORTANT: Disconnect power to the amplifier before operating this switch. IMPORTANT: Make sure this setting is correct before connecting the unit to the mains. PAGE 5 SPECIFICATIONS XRS8P Drivers XRS10P XRS12P 1 x 8” woofer 1 x 10” woofer 1 x 12” woofer 1 x 1.5” HF driver 1 x 1.5” HF driver 1 x 2” HF driver Frequency Response(-3dB) 65Hz-18kHz 55Hz-18kHz 50Hz-18kHz Frequency Response(-10dB) 55Hz-18kHz 50Hz-18kHz 40Hz-20kHz 118dB 121dB 125dB Bass control @ 100Hz 12dB 12dB 12dB Treble control @ 10kHz 10dB 10dB 10dB 100W(low) + 50W(high) 100W(low) + 50W(high) 300W(low) + 100W(high) Line 0.02% 0.02% 0.02% Microphone 0.04% 0.04% 0.04% 90° x 90° 90° x 90° 90° x 90° Peak Sound Level(dB 1m) Tone controls Output Power Distortion (THD) Tweeter Dispersion(HxV) Input Impedance Line 20kOhm 20kOhm 20kOhm Microphone 10kOhm 10kOhm 10kOhm Connectors XLR 3 XLR 3 XLR 3 AC 115V/230V, 50/60Hz AC 115V/230V, 50/60Hz AC 115/230V, 50/60Hz Dimensions(WxDxH) 277 x 265 x 407mm 325 x 308 x 478mm 415 x 391 x 600mm Packing Dimensions(WxDxH) 355 x 325 x 470mm 375 x 355 x 535mm 465 x 435 x 680mm Net Weight 8.6kg 10.5kg 23kg Gross Weight 10.1kg 11.8kg 25.2kg Power Supply PAGE 6 XRS SERIES INSTALLATION AND OPERATION MANUAL SPECIFICATIONS XRS8 XRS10 XRS12 1 x 8” woofer 1 x 10” woofer 1 x 12” woofer 1 x 1.5” HF driver 1 x 1.5” HF driver 1 x 2” HF driver Frequency Response(-3dB) 65Hz-18kHz 55Hz-18kHz 50Hz-18kHz Frequency Response(-10dB) 60Hz-20kHz 50Hz-20kHz 40Hz-20kHz Sensitivity(dB 1W 1m) 92 dB 95 dB 97 dB Impedance 8 Ohm 8 Ohm 8 Ohm Recommended Max Power(Wrms) 100 W 250 W 300 W Max Sound Level(dB 1m) 118dB 125dB 128dB 90° x 90° 90° x 90° 90° x 90° 1% 1% 1% 1 2 2 Dimensions(WxDxH) 277 x 257 x 400mm 321 x 321 x 464mm 415 x 382 x 620mm Packing Dimensions(WxDxH) 595 x 310 x 460mm 375 x 355 x 535mm 465 x 435 x 680mm 6.5kg 10kg 18kg 15kg (pair) 12kg 20kg Drivers Dispersion(HxV) Harmonic Distortion Speakon compatible connectors Net Weight Gross Weight XRS SERIES INSTALLATION AND OPERATION MANUAL PAGE 7 AUSTRALIA AND NEW ZEALAND www.australianmonitor.com.au SYDNEY MELBOURNE ADELAIDE AUCKLAND (NSW SALES) (VIC & TAS SALES) (SA & NT SALES) (NZ SALES) 1 Clyde Street Silverwater NSW 2128 Private Bag 149 Silverwater NSW 1811 Phone: (02) 9647 1411 Fax: (02) 9648 3698 Email: [email protected] 22/277 Middleborough Road Box Hill VIC 3128 PO Box 151 Blackburn South VIC 3130 Phone: (03) 9890 7477 Fax: (03) 9890 7977 Email: [email protected] 31 Walsh Street Thebarton SA 5031 PO Box 157 Hindmarsh SA 5007 Phone: (08) 8352 4444 Fax: (08) 8352 4488 Email: [email protected] 9C Piermark Drive Albany 0752 New Zealand PO Box 300-512 Albany 0752 Phone: (09) 415 9426 Fax: (09) 415 9864 Email: [email protected] CANBERRA BRISBANE PERTH (ACT SALES) (QLD SALES) (WA SALES) 1st Floor, Campion Street Deakin ACT 2600 PO Box 109 Deakin West ACT 2600 Phone: (02) 6260 4544 Fax: (02) 6260 4744 Email: gordon.anderson@ hillssvl.com.au 42 Commercial Road Fortitude Valley QLD 4006 PO Box 2578 Fortitude Valley BC QLD 4006 Phone: (07) 3852 1312 Fax: (07) 3252 1237 Email: [email protected] 3/11 Howe Street Osborne Park WA 6017 PO Box 1281 Osborne Park BC WA 6916 Phone: (08) 9204 0200 Fax: (08) 9244 3783 Email: [email protected] EUROPE / ASIA / MIDDLE EAST www.australianmonitor.com.au INTERNATIONAL SALES 1 Clyde Street Silverwater NSW 2128 Australia Private Bag 149 Silverwater NSW 1811 Phone: + 61 2 9647 1411 Fax: + 61 2 9748 2537 Email: [email protected] 1 2 3 4 5 6 7 8 9 10 12 11 D D Q33 TIP121 R152 +40V 47 2W Q37 J108 MUTE 4 30Vac CF8 DB1 KBU1004 60Vac CF9 变压器 1 C22 220n 1 230V Q34 BC560 R139 4M7 -40V C62 6800U/50V DB2 KBU1004 D44 1N4148 1N4148 Q38 J108 MUTE R142 10M R141 100K -80V R154 4K7 Q36 BC560 R144 C66 56K 470nJ63 R153 100K C67 100n C70 220U/25V R151 2K2 C64 100n CZ03 6P(2.5MM) R150 10K R143 C5 123 C1 10U/25V-NP -15V Q35 TIP126 47 2W 2R2 R1 10K F3 +40V +80V 5AF R11 390 R60 2K2 C8 R10 2K2 R18 100n 2 3 IC1A JRC4558 D24 1N4007 R85 1R52 560 MUTE LOW-IN R69 1K R68 470 R82 0R33 5W R76 47 COUT 30U/100V R57 4UH R84 6K8 5 R74 1K8 Q20 BC550 R70 1K R81 0R33 5W DL4 GREEN R1 JRC4558 47K C1 1nJ100 0R33 5W D23 1N4007 R59 C30 33P 2K2 R86 0R33 5W -15V R75 R73 1K D27 1N4148 560 D4 6K8 Q6 BC550 R37 1K8 Q5 R22 BC560 1K CT04 7P*100MM(2.5MM) -15V +15V C17 334 7R26 1K2 2 1 LOW 3 IC5A C18 JRC4558 333 R27 1K2 C16 333 1K C13 104 R35 Q2 A92 3 1 R21 100K R28 27K +15V R22 1K 2 2 IC1A JRC4558 1 2 3 4 5 6 7 C19 1U/50V R5 3 CF1 2K2 D3 1N4148 C20 1U/50V IC4A JRC4558 R32 R31 1M R33 D2 1M R34 1N4148 10K R30 R29 10K 6 D1 7 47K 2 1 5 C 3 1N4148 IC6B JRC4558 10K R46 IC6A JRC4558 +15V C11 100n R15 560 R8 2K2 D7 BAV21 R43 C29 CV9 104 CV11 104 2R17 B Q1 A92 2K2 1N4148 R18 1M CV2 104 CV4 104 CV6 104 IC2C JRC4558 IC1C JRC4558 IC6C JRC4558 CV8 104 IC3C JRC4558 CV10 104 IC4C JRC4558 C10 2.2U/50V D6 1N4148 R14 R13 1M R15 D5 10K 1M R16 1N4148 R12 R11 10K 6 D4 7 39K 1 12K 3 5 1N4148 IC3B JRC4558 10K C9 104 2R10 IC3A JRC4558 CV12 104 IC5C JRC4558 DZ2 12V D17 1N4148 F2 Q3 2N5401 C20 100n F4 CV7 104 DZ4 12V R27 100 R14 390 D20 MR854 6.3AF Q14 2SC4793 R13 2K2 C15 22u/16V -40V Q10 2SA1943 3R3 1/2W C9 R16 22P/500V D8 1N4148 R63 2K2 -15V Q8 E15031 CV5 104 CF2 C14 100n R34 22 D18 1N4148 CV3 104 CV13 100U/50V 2K2 R38 180K D13 1N4148 R36 1K +15V CV1 104 R40 0R15 5W R24 Q18 2N5401 100n R39 0R15 5W 4UH R33 4R7 5W Q1 2N5401 C32 22P/500V Q25 2N5551 390 L1 C7 R6 2K2 -15V R64 C3 102 C14 22P R23 IC5B JRC4558 R25 1K2 C12 684 DZ1 12V R9 8K2 IC2A JRC4558 10K R20 5K6 1 R44 47 DL2 GREEN R2 47K 1K2 C2 183 22U/16V 5 D7 100P R9 2K2 1N4007 Q28 2SA1837 R66 560 MUTE R3 10K 4K7 6 6 R48 C17 100u/63V CF4 Q22 TIP36C 3R3 1/2W 100 C33 47nJ100 R71 22 D32 1N4148 R58 2K2 D26 BAV21 R83 47K 2K2 1/2W Q26 BC560 C26 100n R55 2K2 R20 470 R36 8K2 C15 154 7R24 4R7 5W 1N4007 R47 7R49 C19 +40V D5 C4 100n R79 R65 560 Q16 2N5401 SIGN A2 C27 100U/63V 68P 6 D21 MR854 R38 R4 100K 2K2 R21 1K D12 1N4007 C12 1nJ100 R35 22 R23 Q13 BC550 33K C6 IC1B 6.3AF Q9 2SC5200 3R3 1/2W R42 180K D11 1N4007 R5 2K2 R41 C3 100n R3 2K2 DL1 GREEN 330 DZ3 12V Q7 E15030 R45 D6 1N4148 Q2 2N5551 R4 10K R80 L2 560 C21 1nJ100 C24 100n CF3 BAV21 R17 D1 2K2 1N4007 R7 2K2 -15V R72 22 2K2 1/2W D31 1N4007 C25 68P 4 3R3 1/2W Q21 BC550 R54 2K2 15K R50 47K D30 1N4007 D19 1N4148 +15V C2 100n Q23 TIP35C F1 R37 3K3 D14 1N4148 R7 8K2 3 123 1 DL3 GREEN R78 C23 100n R51 2K2 Q17 2N5551 R53 10K Q27 2SC4793 R77 D25 1N4148 100 C10 22P/500V R19 10K C4 22P 6 4 HIGH-IN 100 BAV21 R67 D22 2K2 1N4007 C5 100n IC1C JRC4558 Q4 2N5551 R29 4K7 3W IC4B JRC4558 5 7 8 C Q19 2N5551 C16 680P R26 IC1B JRC4558 4 R62 +15V R56 2K2 D9 1N4148 D10 8 C31 22P/500V Q12 IRFP140 8 D28 1N4148 D29 D3 1N4007 2R2 2W Q15 2SA1837 R12 +15V 123 HIGH 1 C8 IC2B 153 JRC4558 C11 10U/25V-NP 5 100K 4 Q24 2N5401 R2 R25 47 8 C28 100n 4 R61 390 C7 7 C6 5 R145 -40V R8 4K7 2 R6 4K7 6 -15V+15V -15V GND +15V HIGH-IN LOW-IN LIMIT 6 5 4 3 2 1 EC 2 3 4 C65 100n 8 2 CF17 10n/2KV +40V C60 6800U/50V C61 6800U/50V 0V CF7 SW C68 220U/25V C69 10U/63V 4 30Vac CF6 T2.5A 100K R147 4K7 8 3 3 CF16 F DZ5 15V D45 R140 C63 2R2 R148 2K2 R149 100 4 POWER INPUT CF5 +15V 8 +80V C59 6800U/50V 60Vac TR R146 Q11 IRFP9140 R30 4K7 3W 330 C13 1nJ100 C18 680P R19 D2 1N4007 R28 47 2R2 2W -40V -80V 5AF D1 1N4148 R3 30K C5 22P IC1B 15K C1 TREBLE IC4A JRC4560 R2 7K5 560 10U/25V-NP R9 1M C3 472 D4 1N4148 -15V J1 R10 10K 1 3 C4 103 R1 10K A50K R2 15K 15K C5 103 R8 15K RP2 B50K BASS 7 5 C8 10U/25V-NP R7 IC4B JRC4560 CON2 5044 10K +15V 1K5 R28 150K 3 1 CV7 104 +15V IC4C JRC4560 C10 10U/25V-NP R8 D8 1N4148 -15V 4 -15V C4 473 D9 IN4148 CV8 104 47 R22 OPT1 22P LCR0202 10K RP1-1 CV5 104 IC3C JRC4560 CV6 LED2 104 GREE +15V 1K5 R29 150K C13 22P R6 5K1 6 R15 10U/25V-NP C17 7 5 10K C15 10U/25V-NP 22P B IC2B JRC4560 R14 RP1-3 2 1 R27 CV3 104 IC2C 10U/25V-NP JRC4560 R10 30K R17 10K R13 3 IC2A JRC4560 2N5551 R12 10K 3 100K 1 RP1-1 47 CON3 5040 LIMIT C22 R26 -15V R25 C14 IC1A SIN-OUT 10K C12 22P -15V C9 +15V 3 47P D7 1N4148 2 LED1 GREE C16 R16 1 2 RP2-3 10K Q3 5K1 D5 1N4148 R9 30K 2 10PIN2.54mm R20 JRC4560 10U/25V-NP C21 22P +15V R5 +15V 8 C6 22P 6 R7 -15V C6 22P D6 1N4148 RP1 OUT1 22P 2 RP1-3 RP1-1 RP1-3 RP1-1 1 2 3 4 5 6 7 8 9 10 R21 10K 10K C19 10U/25V-NP R11 R4 30K IC3A JRC4560 3 C20 7 8 10K 7K5 IN2 JRC4560 IC3B 5 R19 10K 6 R24 3K3 +15V CV1 104 IC1C 2K2 LED3 RED CV8 JRC4560 100U/50V JRC4560 J2A Q1 100 Q2 2N5551 2N5401 R23 100K CV4 104 1 2 3 4 5 6 7 8 9 10 RP2-1 RP2-3 CV2-15V 104 J1A IN2 10PIN2.54mm 4 R4 C18 10U/25V-NP R18 8 R3 IN1 10U/25V-NP 8 C3 RP2-1 5 1 C2 -15V 47P +15V 4 1 R6 3 B RP3 B50K D3 1N4148 2 R5 C7 7 2 6 4 560 +15V D2 1N4148 C1 10U/25V-NP R1 CON1 5044 -15V +15V 1 2 3 4 5 6 7 8 9 10 CT01A CT01 RP1-3 5 4 3 2 1 IN1 -15V -15V -15V GND +15V SIN-OUT LIMIT 5P*100MM(2.5MM) 1 2 3 4 5 6 LIMIT SIN-OUT +15V GND -15V 6P*100MM(2.5MM) +15V 10PIN2.54mm +15V Q4 C11 473 D10 IN4148 2N5551 A A Australian Monitor XRS12P 1 2 3 4 5 6 7 8 9 10 11 12