Configurability | 7
SM Series Heat Pump
CONFIGURABILITY
HORIZONTAL CONFIGURABILITY
The Horizontal Configuration water source heat
pump is designed to have a field configurable
blower orientation: end blow (default) and straight
through. (Figure #4 and #5)
•
•
•
1/4" hex head driver
Needle nose pliers
5/16”-1/4” ratchet wrench
Discharge air configuration change is not
possible on Heat Pumps equipped with
Electric Heat Option.
Instructions - Left-Hand Unit (SM0**1HZ-*L*-**)
1. Remove and retain end and side panels.(Figure
#6)
2
2
Figure # 4
1
1
Figure # 6
2. Disconnect blower motor wiring and ground
wire fastened to blower housing.(Figure#7)
Figure # 5
Left-Hand and Right-hand Horizontal (HZ) units
have different Blower Configuration instructions.
--------------------------------------------------------------Left- Hand unit instructions refer to Pg#7 and
Right-Hand unit instructions refer to Pg#10.
Figure # 7
Internally mounted electric heat is only available
in End Blow configuration.
Blower configuration changes should be done
prior to unit being installed in the final location.
Required Tools
•
•
•
•
•
5/16" hex head driver
3/8" hex head driver
7/16" hex head driver
Flat screw driver
Phillips screw driver
Revised 08-13
6 720 220 406 (2013/9)