Download Carrier 38AQS012 Specifications

Transcript
40RM
40RMQ
40RMS
Packaged Air-Handling Units
50/60 Hz
Installation, Start-Up and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . 1
PRE-INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 1
Moving and Storage . . . . . . . . . . . . . . . . . . . . . . . . 1
Rigging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Uncrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Unit Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Unit Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Refrigerant and Chilled Water
Piping Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Refrigerant Piping . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chilled Water Piping . . . . . . . . . . . . . . . . . . . . . . . 17
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Fan Motors and Drives . . . . . . . . . . . . . . . . . . . . . 18
Power Supply and Wiring . . . . . . . . . . . . . . . . . . . 19
Connecting Ductwork . . . . . . . . . . . . . . . . . . . . . . 22
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . 22
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-39
Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Fan Motor Lubrication . . . . . . . . . . . . . . . . . . . . . . 23
Fan Shaft Bearings . . . . . . . . . . . . . . . . . . . . . . . . . 23
Centering Fan Wheel . . . . . . . . . . . . . . . . . . . . . . . 24
Fan Shaft Position Adjustment . . . . . . . . . . . . . . 24
Individual Fan Wheel Adjustment . . . . . . . . . . . 24
Fan Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Fan Pulley Alignment . . . . . . . . . . . . . . . . . . . . . . . 25
Pulley and Drive Adjustment . . . . . . . . . . . . . . . . 25
Condensate Drains . . . . . . . . . . . . . . . . . . . . . . . . . 25
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Chilled Water Coil Freeze Protection . . . . . . . . 25
Coil Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Cleaning Cooling Coil . . . . . . . . . . . . . . . . . . . . . . 25
Cleaning Insulation . . . . . . . . . . . . . . . . . . . . . . . . 25
Replacing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
START-UP CHECKLIST . . . . . . . . . . . . . . . . CL-1,CL-2
SAFETY CONSIDERATIONS
Installing, starting up, and servicing this equipment can
be hazardous due to system pressures, electrical components
and equipment location (elevated structures, etc.).
Only trained, qualified installers and service mechanics
should install, start up, and service this equipment.
Untrained personnel can perform basic maintenance functions such as cleaning coils, and cleaning and replacing
filters. All other operations should be performed by trained
service personnel.
When working on the equipment, observe precautions in
the literature and on tags, stickers, and labels attached to the
equipment.
• Follow all safety codes.
• Wear safety glasses and work gloves.
• Use care in handling, rigging, and setting bulky
equipment.
Be sure all power to equipment is shut off before performing maintenance or service. More than one disconnect may be present.
PRE-INSTALLATION
Moving and Storage — To transfer unit from truck to
storage site, use a fork truck. Do not stack units more than
2 high during storage. If unit is to be stored for more than
2 weeks before installation, choose a level, dry storage site
free from vibration. Do not remove plastic wrap or skid from
unit until final installation.
Rigging — All 40RM Series units can be rigged by using the shipping skid. Units are shipped fully assembled. Do
not remove shipping skids or protective covering until unit
is ready for final placement; damage to bottom panels can
result. Use slings and spreader bars as applicable to lift unit.
INSTALLATION
General — Allow 21⁄2 ft at front and side of unit for
service clearance and airflow. For units equipped with an economizer, refer to the accessory installation instructions for additional clearance requirements. Be sure floor, wall, or ceiling can support unit weight (Tables 1A-1F). See
Fig. 1A-1C for dimensions.
Uncrating — Move unit as near as possible to final location before removing shipping skid.
Remove metal banding, top skid, and plastic wrap. Examine unit for shipping damage. If shipping damage is
evident, file claim with transportation agency. Remove base
skid just prior to actual installation.
Check nameplate information against available power
supply and model number description in Fig. 2.
Accessories — Refer to instructions shipped with each
accessory for specific information.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 111
Catalog No. 534-053
Printed in U.S.A.
Form 40RM-9SI
Pg 1
11-95
Replaces: 40RM-1SI
Tab 3c 2e
Table 1A — 40RM Physical Data, English
UNIT 40RM
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (lb)
Base Unit with TXV
Plenum
FANS
Qty...Diam. (in.)
Nominal Airflow (cfm)
Airflow Range (cfm)
Nominal Motor Hp (Standard Motor)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
Motor Speed (rpm)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
REFRIGERANT
Operating charge (lb)
(approx per circuit)*
DIRECT-EXPANSION COIL
Max Working Pressure (psig)
Face Area (sq ft)
No. of Splits
No. of Circuits per Split
Split Type...Percentage
Rows...Fins/in.
STEAM COIL
Max Working Pressure (psig at 400 F)
Total Face Area (sq ft)
Rows...Fins/in.
HOT WATER COIL
Max Working Pressure (psig)
Total Face Area (sq ft)
Rows...Fins/in.
Water Volume
(gal)
(ft3)
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)
DX Coil — Liquid Refrigerant (ODF)
Steam Coil, In (MPT)
Steam Coil, Out (MPT)
Hot Water Coil, In (MPT)
Hot Water Coil, Out (MPT)
Condensate (PVC)
FILTERS
Quantity...Size (in.)
Access Location
007
6
008
71⁄2
012
10
014
121⁄2
016
15
024
20
028
25
034
30
381
97
385
97
405
97
670
140
685
140
690
140
1020
180
1030
180
1...15
2400
18003000
1...15
3000
22503750
1...15
4000
30005000
2...15
5000
37506250
2...15
6000
45007500
2...15
8,000
6,00010,000
2...18
10,000
7,50012,500
2...18
12,000
9,00015,000
1.3
2.4
1.0
2.4
2.4
2.4
2.0
2.4
—
2.4
2.0
2.9
—
2.9
3.0
2.9
—
3.7
3.0
2.9
—
5.0
5.0
5.0
—
7.5
7.5
7.5
—
10.0
10.0
10.0
1725
1725
1725
1425
1725
1725
1725
1425
—
1725
1725
1425
—
1725
1725
1425
—
1745
1745
1425
—
1745
1755
1425
—
1745
1755
1425
3.0
3.0
1.5/1.5
2.0/2.0
3.5/3.5
4.5/4.5
5.0/5.0
6.67
1
12
—
3...15
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
435
8.33
10.0
13.25
17.67
19.88
24.86
1
2
2
2
2
2
15
9
9
12
13
15
—
Face...50/50
3...15
3...17
3...15
3...15
3...17
3...15
29.83
2
18
6.67
1...9
6.67
1...9
6.67
1...9
13.33
1...10
175
13.33
1...10
13.33
1...10
15.0
1...10
15.0
1...10
6.67
2...8.5
6.67
2...8.5
6.67
2...8.5
13.33
2...8.5
150
13.33
2...8.5
13.33
2...8.5
15.0
2...12.5
15.0
2...12.5
8.3
1.1
—
1725
1725
1425
R-22
2.5/2.5
13.9
1.85
1...11⁄8
1...11⁄8
1...5⁄8
1...21⁄2
1...11⁄2
1...11⁄2
1...11⁄2
2...11⁄8
2...11⁄8
2...5⁄8
1...21⁄2
1...11⁄2
1...11⁄2
1...2
1...11⁄2
1...2
1...11⁄4 ODM/1 IDF
Throwaway — Factory Supplied
4...16 x 20 x 2
4...16 x 24 x 2
4...16 x 24 x 2
Either Side
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
2
2...11⁄8
2...11⁄8
3...15
14.3
1.90
2...13⁄8
2...13⁄8
4...20 x 24 x 2
4...20 x 25 x 2
Table 1B — 40RMQ Physical Data, English
UNIT 40RMQ
NOMINAL CAPACITY (Tons)
OPERATING WEIGHT (lb)
Base Unit with TXV
Plenum
FANS
Qty...Diam. (in.)
Nominal Airflow (cfm)
Airflow Range (cfm)
Nominal Motor Hp (Standard Motor)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
Motor Speed (rpm)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
REFRIGERANT
Operating charge (lb)
(approx per circuit)*
DIRECT-EXPANSION COIL
Max Working Pressure (psig)
Face Area (sq ft)
No. of Splits
No. of Circuits per Split
Split Type...Percentage
Rows...Fins/in.
STEAM COIL
Max Working Pressure (psig at 400 F)
Total Face Area (sq ft)
Rows...Fins/in.
HOT WATER COIL
Max Working Pressure (psig)
Total Face Area (sq ft)
Rows...Fins/in.
Water Volume
(gal)
(ft3)
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)
DX Coil — Liquid Refrigerant (ODF)
Steam Coil, In (MPT)
Steam Coil, Out (MPT)
Hot Water Coil, In (MPT)
Hot Water Coil, Out (MPT)
Condensate (PVC)
FILTERS
Quantity...Size (in.)
Access Location
008
71⁄2
012
10
016
15
385
97
427
97
713
140
1...15
3000
2250-3750
1...15
4000
3000-5000
2...15
6000
4500-7500
2.4
2.4
2.0
2.4
—
2.4
2.0
2.9
—
3.7
3.0
2.9
1725
1725
1725
1425
—
1725
1725
1425
R-22
2.0/2.0
—
1725
1725
1425
3.0
3.0/3.0
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
435
8.33
10.0
17.67
1
2
2
15
9
16
—
Face...50/50
3...15
4...15
4...15
6.67
1...9
175
6.67
1...9
13.33
1...10
6.67
2...8.5
150
6.67
2...8.5
13.33
2...8.5
8.3
1.1
1...11⁄8
1...5⁄8
1...21⁄2
1...11⁄2
1...11⁄2
1...11⁄2
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
3
13.9
1.85
2...11⁄8
2...5⁄8
2...11⁄8
2...5⁄8
1...21⁄2
1...11⁄2
1...11⁄2
1...2
1...11⁄2
1...2
1...11⁄4 ODM/1 IDF
Throwaway — Factory Supplied
4...16 x 20 x 2
4...16 x 24 x 2
4...16 x 24 x 2
Either Side
Table 1C — 40RMS Physical Data, English
UNIT 40RMS
008
010
012
014
016
024
028
034
NOMINAL CAPACITY (Tons)
71⁄2
8 1 ⁄2
10
121⁄2
15
20
25
30
OPERATING WEIGHT (lb)
Base Unit
390
391
391
661
677
683
1035
1042
Plenum
97
97
97
140
140
140
180
180
FANS
Qty...Diam. (in.)
1...15
1...15
1...15
2...15
2...15
2...15
2...18
2...18
Nominal Airflow (cfm)
3000
3400
4000
5000
6000
8000
10,000
12,000
Airflow Range (cfm)
2250-3750 2250-4250 3000-5000 3750-6250 4500-7500 6000-10,000 7500-12,500 9000-15,000
Nominal Motor Hp
(Standard Motor)
208/230-1-60
2.4
2.4
—
—
—
—
—
—
208/230-3-60 and 460-3-60
2.4
2.4
2.4
2.9
3.7
5.0
7.5
10.0
575-3-60
2.0
2.0
2.0
3.0
3.0
5.0
7.5
10.0
230-3-50 and 400-3-50
2.4
2.4
2.9
2.9
2.9
5.0
7.5
10.0
Motor Speed (rpm)
208/230-1-60
1725
1725
—
—
—
—
—
—
208/230-3-60 and 460-3-60
1725
1725
1725
1725
1725
1745
1745
1745
575-3-60
1725
1725
1725
1725
1725
1745
1755
1755
230-3-50 and 400-3-50
1425
1425
1425
1425
1425
1425
1425
1425
CHILLED WATER COIL
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure
435
(psig)
Face Area (sq ft) — Upper
8.3
9.0
4.9
8.3
8.3
11.0
12.4
15.5
Face Area (sq ft) — Lower
—
—
4.9
5.5
8.3
8.3
12.4
12.4
Rows...Fins/in.
3...15
STEAM COIL
Max Working Pressure
175
(psig at 400 F)
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
1...9
1...9
1...9
1...10
1...10
1...10
1...10
1...10
HOT WATER COIL
Max Working Pressure
150
(in. wg)
Total Face Area (sq ft)
6.67
6.67
6.67
13.33
13.33
13.33
15.0
15.0
Rows...Fins/in.
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...8.5
2...12.5
2...12.5
Water Volume
(gal)
8.3
13.9
14.3
(ft3)
1.1
1.85
1.90
PIPING CONNECTIONS,
Quantity...Size (in.)
Chilled Water — In
1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM
Chilled Water — Out
1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM
Steam Coil, In (MPT)
1...21⁄2
1...21⁄2
Steam Coil, Out (MPT)
1...11⁄2
1...11⁄2
Hot Water Coil, In (MPT)
1...11⁄2
1...11⁄2
1...2
Hot Water Coil, Out (MPT)
1...11⁄2
1...11⁄2
1...2
Condensate (PVC)
1...11⁄4 ODM/1 IDF
FILTERS
Throwaway — Factory Supplied
4...16 x 20 x 2
4...20 x 24 x 2
Quantity...Size (in.)
4...16 x 24 x 2
4...16 x 24 x 2
4...20 x 25 x 2
Access Location
Either Side
4
Table 1D — 40RM Physical Data, SI
UNIT 40RM
007
008
012
014
016
024
028
034
NOMINAL CAPACITY (kW)
21
26
35
43
52
70
87
105
OPERATING WEIGHT (kg)
Base Unit with TXV
173
175
184
304
311
313
463
467
Plenum
44
44
44
63
63
63
82
82
FANS
Qty...Diam. (mm)
1...381
1...381
1...381
2...381
2...381
2...381
2...457
2...457
Nominal Airflow (L/s)
1133
1604
1888
2360
2831
3775
4719
5663
Airflow Range (L/s)
850-1416 1203-2006 1416-2360 1770-2949 2124-3539 2831-4719 3539-5899 4247-7079
Nominal Motor kW (Standard Motor)
208/230-1-60
0.97
1.79
—
—
—
—
—
—
208/230-3-60 and 460-3-60
1.79
1.79
1.79
2.16
2.76
3.73
5.60
7.46
575-3-60
0.75
1.49
1.49
2.24
2.24
3.73
5.60
7.46
230-3-50, 400-3-50
1.79
1.79
2.16
2.16
2.16
3.73
5.60
7.46
Motor Speed (r/s)
208/230-1-60
28.8
28.8
—
—
—
—
—
—
208/230-3-60 and 460-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.1
29.1
575-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.3
29.3
230-3-50, 400-3-50
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
REFRIGERANT
R-22
Operating charge (kg)
1.36
1.36
0.68/0.68 0.90/0.90 1.13/1.13 1.59/1.59 2.04/2.04 2.27/2.27
(approx per circuit)*
DIRECT-EXPANSION COIL
Enhanced Copper Tubes, Aluminum Sine-Wave Fins
Max Working Pressure (kPag)
2999
Face Area (sq m)
0.62
0.77
0.93
0.93
1.64
1.85
2.30
2.77
No. of Splits
1
1
2
2
2
2
2
2
No. of Circuits per Split
12
15
9
9
12
13
15
18
Split Type...Percentage
—
—
Face...50/50
Rows...Fins/m
3...591
3...591
3...670
3...591
3...591
3...670
3...591
3...591
STEAM COIL
Max Working Pressure (kPag at 204.4 C)
1207
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
1...355
1...355
1...355
1...394
1...394
1...394
1...394
1...394
HOT WATER COIL
Max Working Pressure (kPag)
1034
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
2...335
2...335
2...335
2...335
2...335
2...335
2...493
2...493
Water Volume
(L)
31.4
52.6
54.1
(m3)
0.031
0.052
0.054
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)
1...11⁄8
1...11⁄8
2...11⁄8
2...11⁄8
2...11⁄8
2...11⁄8
2...13⁄8
2...13⁄8
DX Coil — Liquid Refrigerant (ODF)
1...5⁄8
2...5⁄8
Steam Coil, In (MPT)
1...21⁄2
1...21⁄2
Steam Coil, Out (MPT)
1...11⁄2
1...11⁄2
Hot Water Coil, In (MPT)
1...11⁄2
1...11⁄2
1...2
Hot Water Coil, Out (MPT)
1...11⁄2
1...11⁄2
1...2
Condensate (PVC)
1...11⁄4 ODM/1 IDF
FILTERS
Throwaway — Factory Supplied
4...406 x 508 x 51
4...508 x 610 x 51
Quantity...Size
4...406 x 610 x 51
4...406 x 610 x 51
4...508 x 635 x 51
Access Location
Either Side
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
5
Table 1E — 40RMQ Physical Data, SI
UNIT 40RMQ
NOMINAL CAPACITY (kW)
OPERATING WEIGHT (kg)
Base Unit with TXV
Plenum
FANS
Qty...Diam. (mm)
Nominal Airflow (L/s)
Airflow Range (L/s)
Nominal Motor kW (Standard Motor)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
Motor Speed (r/s)
208/230-1-60
208/230-3-60 and 460-3-60
575-3-60
230-3-50, 400-3-50
REFRIGERANT
Operating charge (kg)
(approx per circuit)*
DIRECT-EXPANSION COIL
Max Working Pressure (kPag)
Face Area (sq m)
No. of Splits
No. of Circuits per Split
Split Type...Percentage
Rows...Fins/m
STEAM COIL
Max Working Pressure (kPag at 204.4 C)
Total Face Area (sq m)
Rows...Fins/m
HOT WATER COIL
Max Working Pressure (kPag)
Total Face Area (sq m)
Rows...Fins/m
Water Volume
(L)
(m3)
PIPING CONNECTIONS,
Quantity...Size (in.)
DX Coil — Suction (ODF)
DX Coil — Liquid Refrigerant (ODF)
Steam Coil, In (MPT)
Steam Coil, Out (MPT)
Hot Water Coil, In (MPT)
Hot Water Coil, Out (MPT)
Condensate (Male PVC)
FILTERS
Quantity...Size
Access Location
008
26
012
35
016
52
175
44
194
44
323
63
1...381
1604
1203-2006
1...381
1888
1416-2360
2...381
2831
2124-3539
1.79
1.79
1.49
1.79
—
1.79
1.49
2.16
—
2.76
2.24
2.16
28.8
28.8
28.8
23.8
—
28.8
28.8
23.8
R-22
—
28.8
28.8
23.8
1.36
0.91/0.91
1.36/1.36
2999
0.93
2
9
0.77
1
15
—
3...591
1.64
2
16
4...591
4...591
0.62
1...355
1207
0.62
1...355
1.24
1...394
0.62
2...335
1034
0.62
2...335
1.24
2...335
Face...50/50
31.4
0.031
1...11⁄8
1...5⁄8
1...21⁄2
1...11⁄2
1...11⁄2
1...11⁄2
52.6
0.052
2...11⁄8
2...5⁄8
2...11⁄8
2...5⁄8
1...21⁄2
1...11⁄2
1...11⁄2
1...2
1...11⁄2
1...2
1...11⁄4 ODM/1 IDF
Throwaway — Factory Supplied
4...406 x 508 x 51
4...406 x 610 x 51
4...406 x 610 x 51
Either Side
LEGEND
TXV — Thermostatic Expansion Valve
*Units are shipped without refrigerant charge.
6
Table 1F — 40RMS Physical Data, SI
UNIT 40RMS
NOMINAL CAPACITY (kW)
OPERATING WEIGHT (kg)
Base Unit
Plenum
FANS
Qty...Diam. (mm)
Nominal Airflow (L/s)
008
26
010
29
012
35
014
43
016
52
024
70
028
87
034
105
177
44
177
44
177
44
300
63
307
63
310
63
469
82
473
82
1...381
1416
10621770
1...381
1605
12042006
1...381
1888
14162360
2...381
2360
17702949
2...381
2831
21243539
2...381
3775
28314719
2...457
4719
35395899
2...457
5663
42477079
Airflow Range (L/s)
Nominal Motor kW
(Standard Motor)
208/230-1-60
1.79
1.79
—
—
—
—
—
—
208/230-3-60, 460-3-60
1.79
1.79
1.79
1.79
2.76
3.73
5.60
7.46
575-3-60
1.49
1.49
1.49
1.49
2.24
3.73
5.60
7.46
230-3-50, 400-3-50
1.79
1.79
2.16
2.16
2.16
3.73
5.60
7.46
Motor Speed (r/s)
208/230-1-60
28.8
28.8
—
—
—
—
—
—
208/230-3-60, 460-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.1
29.1
575-3-60
28.8
28.8
28.8
28.8
28.8
29.1
29.3
29.3
230-3-50, 400-3-50
23.8
23.8
23.8
23.8
23.8
23.8
23.8
23.8
CHILLED WATER COIL
Max Working Pressure
2999
(kPag)
Face Area (sq m) — Upper
0.77
0.84
0.91
0.77
0.77
1.02
1.15
1.44
Face Area (sq m) — Lower
—
—
—
0.51
0.77
0.77
1.15
1.15
Rows...Fins/m
3...591
3...591
3...591
3...591
3...591
3...591
3...591
3...591
STEAM COIL
Max Working Pressure
1207
(kPag at 204.4 C)
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
1...355
1...355
1...355
1...355
1...394
1...394
1...394
1...394
HOT WATER COIL
Max Working Pressure
1034
(kPag)
Total Face Area (sq m)
0.62
0.62
0.62
1.24
1.24
1.24
1.39
1.39
Rows...Fins/m
2...335
2...335
2...335
2...335
2...335
2...335
2...493
2...493
Water Volume
(L)
31.4
52.6
54.1
(m3)
0.031
0.052
0.054
PIPING CONNECTIONS,
Quantity...Size (in.)
Chilled Water — In
1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM
Chilled Water — Out
1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM
1...21⁄2
Steam Coil, In (MPT)
1...21⁄2
Steam Coil, Out (MPT)
1...11⁄2
1...11⁄2
Hot Water Coil, In (MPT)
1...11⁄2
1...11⁄2
1...2
1...11⁄2
1...2
Hot Water Coil, Out (MPT)
1...11⁄2
Condensate (PVC)
1...11⁄4 ODM/1 IDF
FILTERS
Throwaway — Factory Supplied
4...406 x 508 x 51
4...508 x 610 x 51
Quantity...Size (mm)
4...406 x 610 x 51
4...406 x 610 x 51
4...508 x 635 x 51
Access Location
Either Side
7
TXV — Thermostatic Expansion Valve
NOTES:
1. Dimensions in [ ] are in millimeters.
2.
Direction of airflow.
3. Recommended clearance:
• Rear: 3 in. (76 mm )
• Front: 2 ft, 6 in. (762 mm)
• Right Side: 2 ft, 6 in. (762 mm)
• Left Side: 2 ft, 6 in. (762 mm)
• Local codes or jurisdiction may prevail.
4. Liquid piping not supplied by Carrier.
5. Duct flange is factory supplied and field
installed.
6. 40RMS units may require alternate or additional field-fabricated piping access holes.
UNIT
40RM007
40RM008
40RM012
40RMQ008
40RMQ012
40RMS008
40RMS010
40RMS012
Fig. 1A — Dimensions — Sizes 007-012
8
UNIT WEIGHT
lb (kg)
381 (173)
385 (175)
405 (184)
385 (175)
427 (194)
390 (177)
391 (177)
391 (177)
TXV — Thermostatic Expansion Valve
NOTES:
1. Dimensions in [ ] are in millimeters.
2.
Direction of airflow.
3. Recommended clearance:
• Rear: 3 in. (76 mm)
• Front: 2 ft, 6 in. (762 mm)
• Right Side: 2 ft, 6 in. (762 mm)
• Left Side: 2 ft, 6 in. (762 mm)
• Local codes or jurisdiction may
prevail.
4. Liquid piping not supplied by Carrier.
5. Duct flange is factory supplied and field
installed.
6. 40RMQ016 and 40RMS units may require alternate or additional field-fabricated
piping access holes.
UNIT
40RM014
40RM016
40RM024
40RMQ016
40RMS014
40RMS016
40RMS024
Fig. 1B — Dimensions — Sizes 014-024
9
UNIT WEIGHT
lb (kg)
670 (304)
685 (311)
690 (313)
713 (323)
661 (300)
677 (307)
683 (310)
UNIT WEIGHT
lb (kg)
40RM028
1020 (463)
40RM034
1030 (467)
40RMS028
1035 (469)
40RMS034
1042 (473)
UNIT
TXV — Thermostatic Expansion Valve
NOTES:
1. Dimensions in [ ] are in millimeters.
2.
Direction of airflow.
3. Recommended clearance:
• Rear: 3 in. (76 mm)
• Front: 2 ft, 6 in. (762 mm)
• Right Side: 2 ft, 6 in. (762 mm)
• Left Side: 2 ft, 6 in. (762 mm)
• Local codes or jurisdiction may
prevail.
4. Liquid piping not supplied by Carrier.
5. Duct flange is factory supplied and field
installed.
6. 40RMS units may require alternate or
additional field-fabricated piping access holes.
Fig. 1C — Dimensions — Sizes 028,034
10
*YC and WD option codes for all 034 size units and 008, 010 units with 208/230-1-60
power designate standard motor and high-static drive.
NOTE: See the following table for the sizes available for each unit.
UNIT
40RM
40RMQ
40RMS
007
X
008
X
X
X
010
X
012
X
X
X
014
X
X
016
X
X
X
024
X
028
X
034
X
X
X
X
Fig. 2 — Model Number Nomenclature
Unit Positioning — The unit can be mounted on the
floor for vertical application with return air entering the face
of the unit and supply air discharging vertically through the
top of the unit. The unit can also be applied in a horizontal
arrangement with return air entering horizontally and the supply air discharging horizontally. When applying the unit in
a horizontal arrangement, ensure the condensate drain pan is
located at the bottom center of the unit for adequate condensate disposal. See Fig. 3 for condensate connections for
each unit position.
Typical positioning and alternate return air locations are
shown in Fig. 3. Alternate return air locations can be used by
moving the unit panel from the alternate return air location
to the standard return air location.
LEGEND
Accessory Line
Alternate Air Intake and Discharge
Air Intake and Discharge
Fig. 3 — Typical Unit Positioning
IMPORTANT: Do NOT attempt to install unit with
return air entering top panel of unit. Condensate will
not drain from unit.
11
Unit Isolation — Where extremely quiet operation is
essential, install isolators between floor and base of unit, or
between ceiling and top section of unit.
Be sure that unit is level and adequately supported. Use
channels at front and sides of unit for reference points when
leveling.
Refrigerant Piping — See Tables 1A, 1B, 1D, 1E for
refrigerant pipe connection sizes. For ease in brazing, it is
recommended that all internal solder joints be made before
unit is placed in final position.
The 40RM and 40RMQ direct-expansion units have
internal factory-installed thermostatic expansion valves (TXVs),
distributors, and nozzles for use with R-22. See Table 2 for
part numbers. Knockouts are provided in the unit corner posts
for 40RM and 40RMQ008 and 012 refrigerant piping. The
40RMQ016 unit requires additional field-fabricated piping
access holes. See Fig. 4, which also lists recommended knockouts and access holes to use for each 40RM and 40RMQ
unit size. Recommended fittings are listed in Table 3.
The sensor bulb capillary tubes must be routed from the
TXVs inside the unit through one of the piping access holes.
Clamp the TXV sensor bulb on a vertical portion of the suction line, outside the unit. See Fig. 5.
Refrigerant and Chilled Water Piping Access —
The 40RM Series units come with standard knockouts for
refrigerant and chilled water piping. These knockouts are located on both sides of the unit for installation flexibility. The
standard knockouts provide sufficient access to the unit’s coils
for all 40RM and some 40RMQ units, however, for 40RMQ016
and 40RMS units, additional holes must be field-fabricated
to accommodate the piping. See Fig. 4 for the positions and
dimensions of the additional access holes required for these
units, including hole diameters and drilling dimensions. Recommended access hole use is also listed for all units. Note
that Fig. 4 shows the access holes on the control-box side of
the unit; this is the side of the unit with the coil headers, so
it is used most often for piping access.
UNIT
USE HOLE
NUMBERS
40RM007,008
40RMQ008
40RM012-034
40RMQ012
40RMS008-012
40RMS014-024
40RMQ016
40RMS028,034
1, 3
FIELD-FABRICATED HOLE DIAMETERS,
in. (mm)
No. 5
No. 6
No. 7
No. 8
A
FIELD-FABRICATED HOLE POSITION
DIMENSIONS, in. (mm)
B
C
D
—
—
—
—
—
—
—
—
1, 2, 3, 4
—
—
—
—
—
—
—
—
4, 5
4, 5, 6, 7
3*, 5, 6, 7
5, 6, 7, 8
1 ⁄ (44.5)
13⁄4 (44.5)
11⁄8 (28.6)
21⁄2 (63.5)
—
13⁄4 (44.5)
11⁄8 (28.6)
21⁄2 (63.5)
—
13⁄4 (44.5)
13⁄4 (44.5)
21⁄2 (63.5)
—
—
—
21⁄2 (63.5)
6.25 (158.8)
3.0 (76.2)
3.25 (82.6)
6.0 (152.4)
—
6.0 (152.4)
6.125 (155.6)
9.625 (244.5)
—
10.5 (266.7)
10.38 (263.7)
13.38 (339.9)
—
—
—
17.0 (431.8)
34
*Must be enlarged from 11⁄8 in. to 13⁄4 inches.
NOTE: Access hole knockouts 1-4 are factory-supplied.
Fig. 4 — Refrigerant and Chilled Water Piping Access Holes
12
IMPORTANT: Never attach the sensor to the suction
manifold. Do NOT mount the sensor on a trapped portion of the suction line.
40RM Series evaporator coils have a face-split design. Ensure that lower circuit of coil is first on/last off when connected to the condensing unit and/or system controls. See
Fig. 6.
External TXV equalizer connections are provided and factorybrazed into the coil suction manifolds.
If suction line must be horizontal, clamp bulb to suction
line at least 45 degrees above bottom, at approximately the
4 o’clock or 8 o’clock position. See Fig. 7.
NOTE: The 40RMQ units are supplied with factory-installed
thermostatic expansion valves and check valve bypasses.
No extra piping connections or kits are required to install the
40RMQ with a 38AQS condensing unit in a heat pump
system, however, some field supplied components may be
required. See the following two sections.
FIRST ON/LAST OFF=B
VERTICAL INSTALLATION
FIRST ON/LAST OFF=A
HORIZONTAL INSTALLATION
Fig. 6 — Typical Evaporator Coil Connections
(40RM, 40RMQ)
LEGEND
TXV — Thermostatic Expansion Valve
NOTE: Component location arrangement shown for field installation
of sight glasses, solenoid valves, filter driers, and TXV sensing bulbs.
The TXVs and equalizer lines are factory installed.
Fig. 5 — Face-Split Coil Suction and
Liquid Line Piping (Typical)
LEGEND
TXV — Thermostatic Expansion Valve
NOTE: The 8 o’clock position is shown above.
Fig. 7 — TXV Sensing Bulb Location
13
Table 2 — Factory-Installed Nozzle and Distributor Data
UNIT
TXV
Qty...Part No.
DISTRIBUTOR
Qty...Part No.
40RM007
40RM008
40RMQ008
40RM012
40RMQ012
40RM014
40RM016
40RMQ016
40RM024
40RM028
40RM034
1...XVE-5
1...SVE-8
1...SVE-8
2...XVE-4
2...XVE-4
2...XVE-5
2...XVE-8
2...SVE-8
2...XVE-10
2...EBSVE-11
2...SVE-15
1...1116
1...1126
1...1657
2...1115
2...1655
2...1115
2...1116
2...1126
2...1116
2...1126
2...1126
FEEDER TUBES
PER DISTRIBUTOR*
Qty...Size (in.)
12
15
15
9
9
9
12
16
13
15
18
NOZZLE
Qty...Part No.
1...E5
1...C6
1...C6
2...E4
2...E4
2...E5
2...E6
2...C6
2...E8
2...C10
2...C12
* Feeder tube size is 1⁄4 in. (6.35 mm).
NOTE: Hot gas bypass applications require field-supplied auxiliary side connector.
38AQS008/40RMQ008 HEAT PUMP SYSTEM PIPING —
Addition of a liquid solenoid valve (LLSV) is recommended
when the piping system length exceeds 75 feet. The LLSV
must be a bi-flow type suited for use in heat pump systems.
The recommended valve is Sporlan model CB14S2 (5/8-in.
ODF, 7/8-in. ODM) available from the Replacement Components Division as part number EF23JS-214. This solenoid
valve requires Sporlan part no. MKC-2 coils that must be
purchased locally. Wire the solenoid valve in parallel with
the compressor contactor coil.
The LLSV must be installed at the outdoor unit with the
flow arrow pointed toward the outdoor unit (in-flow
direction for the heating mode.)
LEGEND
TXV — Thermostatic Expansion Valve
RECOMMENDED FILTER DRIERS*
(38AQS012,016/40RMQ SYSTEMS)
FILTER DRIER REQUIREMENTS FOR 38AQS012/
40RMQ012 AND 38AQS016/40RMQ016 HEAT PUMP
SYSTEMS — The 38AQS012 and 016 units do not include filter driers. Filter driers must be field-supplied
and installed in 38AQS012/40RMQ012 and 38AQS016/
40RMQ016 systems. The filter driers used with these systems must be bi-flow types suited for use in heat pump
applications. The Replacement Component Division part numbers listed in Fig. 8 are recommended and available for field
installation.
UNIT
38AQS
012
016
LIQUID
LINE
SIZE
(in.)
1⁄2
5⁄8
1⁄2
5⁄8
PART NO.
P504-8084S
P504-8165S
P504-8084S
P504-8085S
QUANTITY
FIGURE
REQUIRED REFERENCE
2
1
2
2
A
B
A
A
*Available from Carrier Replacement Components Division.
Fig. 8 — Filter Drier Requirements —
38AQS012/40RMQ012 and 38AQS016/40RMQ016
Heat Pump Systems
14
Table 3 — Fitting Requirements
UNIT
ACCESS
HOLE NO.*
CONNECTION
TYPE
CIRCUIT
1
Suction
—
3
Liquid
—
1
Suction
—
3
Liquid
—
4
Return
—
5
Supply
—
1
Suction
Lower
2
Liquid
Lower
3
Liquid
Upper
4
Suction
Upper
1
Suction
Lower
2
Liquid
Lower
3
Liquid
Upper
4
Suction
Upper
1
Suction
Lower
2
Liquid
Lower
3
Liquid
Upper
4
Suction
Upper
4
Supply
Lower
5
Return
Lower
6
Return
Upper
7
Supply
Upper
40RM
007
40RM
40RMQ
008
40RMS
008-012
40RM
012
40RMQ
012
40RM
014
40RMS
014-024
*See Fig. 4 for access hole location by number.
†Fittings are listed in order from header or tee stub connection out to access hole in corner support post.
15
FITTINGS REQUIRED†
(in.)
11⁄8 Street Elbow
11⁄8 Nipple, 105⁄8 L
11⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 85⁄8 L
5⁄8 Long Radius Elbow
11⁄8 Street Elbow
11⁄8 Nipple, 85⁄8 L
11⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 85⁄8 L
5⁄8 Long Radius Elbow
13⁄8 Nipple, 43⁄8 L
13⁄8 Long Radius Elbow
13⁄8 Nipple, 73⁄8 L
13⁄8 Long Radius Elbow
13⁄8 Nipple, 65⁄8 L
13⁄8 Long Radius Elbow
(2) 11⁄8 Street Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 81⁄2 L
5⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 131⁄2 L
5⁄8 Long Radius Elbow
11⁄8 Nipple, 53⁄4 L
11⁄8 Long Radius Elbow
11⁄8 Nipple, 12 L
11⁄8 Long Radius Elbow
(2) 11⁄8 Street Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 51⁄2 L
5⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 101⁄2 L
5⁄8 Long Radius Elbow
11⁄8 Nipple, 55⁄8 L
11⁄8 Long Radius Elbow
11⁄8 Nipple, 12 L
11⁄8 Long Radius Elbow
11⁄8 Street Elbow
11⁄8 Nipple, 75⁄8 L
11⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 17⁄16 L
5⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 111⁄2 L
5⁄8 Long Radius Elbow
11⁄8 Nipple, 55⁄8 L
11⁄8 Long Radius Elbow
11⁄8 Nipple, 13 L
11⁄8 Long Radius Elbow
13⁄8 Long Radius Elbow
13⁄8 Nipple, 33⁄4 L
13⁄8 Long Radius Elbow
13⁄8 Long Radius Elbow
13⁄8 Nipple, 33⁄8 L
13⁄8 Long Radius Elbow
13⁄8 Long Radius Elbow
13⁄8 Nipple, 7 L
13⁄8 Long Radius Elbow
13⁄8 Long Radius Elbow
13⁄8 Nipple, 113⁄4 L
13⁄8 Long Radius Elbow
Table 3 — Fitting Requirements (cont)
UNIT
40RM
016
40RMQ
016
40RM
024
40RM
028
ACCESS
HOLE NO.*
CONNECTION
TYPE
CIRCUIT
1
Suction
Lower
2
Liquid
Lower
3
Liquid
Upper
4
Suction
Upper
3
Suction
Lower
5
Liquid
Lower
6
Liquid
Upper
7
Suction
Upper
1
Suction
Lower
2
Liquid
Lower
3
Liquid
Upper
4
Suction
Upper
1
Suction
Lower
2
Liquid
Lower
3
Liquid
Upper
4
Suction
Upper
*See Fig. 4 for access hole location by number.
†Fittings are listed in order from header or tee stub connection out to access hole in corner support post.
16
FITTINGS REQUIRED†
(in.)
11⁄8 Street Elbow
11⁄8 Nipple, 23⁄4 L
11⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 13⁄8 L
5⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 111⁄2 L
5⁄8 Long Radius Elbow
11⁄8 Nipple, 55⁄8 L
11⁄8 Long Radius Elbow
11⁄8 Nipple, 13 L
11⁄8 Long Radius Elbow
11⁄8 Nipple, 3 L
11⁄8 Long Radius Elbow
5⁄8 Nipple, 27⁄8 L
5⁄8 45° Elbow
5⁄8 Nipple, 15⁄8 L
5⁄8 Long Radius Elbow
5⁄8 Nipple, 27⁄8 L
5⁄8 45° Elbow
5⁄8 Nipple, 41⁄4 L
5⁄8 Long Radius Elbow
11⁄8 Nipple, 5 L
11⁄8 45° Elbow
11⁄8 Nipple, 83⁄4 L
11⁄8 Long Radius Elbow
11⁄8 Street Elbow
11⁄8 Nipple, 75⁄8 L
11⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 61⁄2 L
5⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 91⁄2 L
5⁄8 Long Radius Elbow
11⁄8 Nipple, 55⁄8 L
11⁄8 Long Radius Elbow
11⁄8 Nipple, 11 L
11⁄8 Long Radius Elbow
13⁄8 Street Elbow
13⁄8 Nipple, 11 L
13⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 11⁄2 L
5⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 193⁄4 L
5⁄8 Long Radius Elbow
13⁄8 Nipple, 43⁄16 L
13⁄8 Long Radius Elbow
13⁄8 Nipple, 231⁄4 L
13⁄8 Long Radius Elbow
Table 3 — Fitting Requirements (cont)
UNIT
ACCESS
HOLE NO.*
CONNECTION
TYPE
CIRCUIT
5
Supply
Lower
6
Return
Lower
7
Return
Upper
8
Supply
Upper
1
Suction
Lower
2
Liquid
Lower
3
Liquid
Upper
4
Suction
Upper
40RMS
028, 034
40RM
034
FITTINGS REQUIRED†
(in.)
21⁄8 Long Radius Elbow
21⁄8 Nipple, 31⁄2 L
21⁄8 Long Radius Elbow
21⁄8 Long Radius Elbow
21⁄8 Nipple, 3 L
21⁄8 Long Radius Elbow
21⁄8 Long Radius Elbow
21⁄8 Nipple, 67⁄8 L
21⁄8 Long Radius Elbow
21⁄8 Long Radius Elbow
21⁄8 Nipple, 117⁄8 L
21⁄8 Long Radius Elbow
13⁄8 Street Elbow
13⁄8 Nipple, 3 L
13⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 73⁄4 L
5⁄8 Long Radius Elbow
5⁄8 Street Elbow
5⁄8 Nipple, 181⁄2 L
5⁄8 Long Radius Elbow
13⁄8 Nipple, 43⁄16 L
13⁄8 Long Radius Elbow
13⁄8 Nipple, 191⁄4 L
13⁄8 Long Radius Elbow
*See Fig. 4 for access hole location by number.
†Fittings are listed in order from header or tee stub connection out to access hole in corner support post.
To size, design, and install chilled water piping, consult
the Carrier System Design manual. See Fig. 9 for an example of a typical installation. Recommended fittings are listed
in Table 3.
To access 40RMS coil vents and drains, remove the unit
side panel over the coil header. Vent and drain plugs are on
the top and bottom of header, respectively. See the Service
section for information on preventing coil freeze-up during
winter.
Chilled Water Piping — See Tables 1C and 1F for
chilled water connection sizes. For ease in brazing, it is recommended that all internal solder joints be made before unit
is placed in final position.
Knockouts are provided in the unit corner posts for 40RM
and 40RMQ refrigerant piping; additional field-fabricated access holes are required for 40RMS chilled water piping. See
Fig. 4, which lists recommended knockouts and access holes
to use for each 40RMS unit size.
Fig. 9 — Typical 40RMS Chilled Water Piping
17
outlet at both ends of the unit, push drain pan down in
the slots near the drain connection, and up in the slots
on the opposite end. Retighten screws. The pan should
have a pitch of at least 1⁄4-in. over its length toward the drain
connection.
Condensate Drain — Install a trapped condensate drain
line to unit connection as shown in Fig. 10. The unit drain
connection is a PVC stub. See Fig. 11. Some areas may require an adapter to connect to either galvanized steel or
copper pipe. For these applications, install a field-supplied
threaded PVC adapter.
NOTE: A trap must be installed in the condensate drain line
to ensure that the static pressure of fans is balanced with the
water column in the drain line and that condensate can drain
completely from pan. Without a trap, air can be drawn up
drain line until water level in condensate pan becomes equal
to static pressure created by fans, preventing complete drainage. Conditions will worsen as filters become dirty.
Install clean-out plugs in trap. Pitch drain line downward
to an open floor drain or sump. Provide service clearance
around drain line to permit removal of unit panels. Observe
all local sanitary codes.
As shipped, the unit’s condensate drain pan is NOT sloped
towards the drain connection. The pan slope must be changed
to pitch towards the side of the unit with the drain connection. See Fig. 11. Loosen the 2 screws next to the drain
Fan Motors and Drives — Motor and drive packages are factory installed in all units. The standard motor
and drive packages consist of the following items:
1 — fan motor
1 — adjustable motor pulley
1 — fan pulley
1 —fan belt (40RM007-016, 40RMQ008-016, 40RMS
008-016 units)
2 —matched fan belts (40RM024-034, 40RMS024-034
units)
For instructions on changing fan rotation, changing drive
speeds and adjusting drives, see Pulley and Drive Adjustment in the Service section.
Fig. 11 — Drain Pan Slope Adjustment
NOTE: Dimensions in [
] are in millimeters.
Fig. 10 — Condensate Drains
18
230-v, 3-ph, 60 Hz operation. Rewire the motor according to
the diagram plate on the motor. After reconfiguring the motor, place the sticker specifying 230-v operation (supplied in
installation packet) over the 460-v sticker on the units corner post.
Fan motors are factory installed on all units. Indoor-fan
contactors are located in the fan contactor box behind the
side access panel (see Fig. 12 and 13). Wire the thermostat
to the 24-v control circuit terminal block located in the side
of the fan contactor control box, according to Fig. 14 or the
unit label diagram. If the air handler is part of a split system,
complete the wiring from the condensing unit to the thermostat shown in Fig. 14.
Power Supply and Wiring — Check the unit data
plate to ensure that available power supply matches electrical characteristics of the unit. Provide a disconnect switch of
size required to provide adequate fan motor starting current.
See Tables 4 - 6 for unit electrical data.
Install disconnect switch and power wiring in accordance
with all applicable local codes. See Fig. 12-14 and the unit
label diagram. For units with motor sizes less than 5 Hp
(3.7 kW), connect power wiring to unit with no. 10 ring terminal. For units with motor sizes of 5 Hp (3.7 kW) or more,
connect power wiring with 1⁄4-in. ring terminal.
The 40RM, 40RMQ and 40RMS size 007-016 units (except 40RM016 with YC or WD option) that have motors wired
for 460-v, 3-ph, 60 Hz operation can be field-converted to
105° C 600V
RJ AW
FAN DRIVE
PULLEY
13
TXV BULB
ACCESS
FAN
CONTACTOR
FILTER
RETAINER
CLIP
12
FILTER
ELEMENTS
11
COIL
23
CONDENSATE
DRAIN
CONNECTION
(HORIZONTAL)
WIRING
ACCESS
22
MOTOR
AND DRIVE
FAN
CONTACTOR
BOX
21
FAN SCROLL
REFRIGERANT/
CHILLED WATER
PIPING ACCESS
24V
TERMINAL
BLOCK
CONDENSATE
DRAIN
CONNECTION
(VERTICAL)
POWER
WIRING
KNOCKOUT
TXV — Thermostatic Expansion Valve
Fig. 13 — Fan Contactor Box and Terminal Block
(Cover Removed) (Typical)
Fig. 12 — Wiring and Service Access
(Side Panel Removed)
19
Table 4 — Electrical Data, Standard Motors
UNIT
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
FAN MOTOR
V*-PH-HZ
VOLTAGE
LIMITS
Hp
FLA
208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-1-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
440-3-50
187-253
187-253
414-528
518-632
207-253
360-440
187-253
187-253
414-528
518-632
207-253
360-440
187-253
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
1.3
2.4
2.4
1.0
2.4
2.4
2.4
2.4
2.4
2.0
2.4
2.4
2.4
2.4
2.4
2.0
2.4
2.4
2.4
2.4
2.0
2.9
2.9
2.9
2.9
3.0
2.9
2.9
3.7
3.7
3.0
2.9
2.9
5.0
5.0
5.0
5.0
5.0
7.5
7.5
7.5
7.5
7.5
10.0
10.0
10.0
10.0
10.0
7.6
5.8
2.6
1.35
5.8
2.6
11.0
5.8
2.6
2.4
5.8
2.6
11.0
5.8
2.6
2.4
5.8
2.6
5.8
2.6
2.4
7.5
3.4
7.5
3.4
3.8
7.5
3.4
10.6
4.8
3.8
7.5
3.4
15.2/14.4
7.2
5.6
14.4
7.2
22.0/21.0
10.5
7.6
21.0
10.5
26.4/25.0
12.5
9.6
25.0
12.5
See Legend and Notes on page 21.
20
POWER SUPPLY
Minimum
MOCP
Circuit Amps
9.5
15
7.3
15
3.3
15
1.7
15
7.3
15
3.3
15
13.8
20
7.3
15
3.3
15
3.0
15
7.3
15
3.3
15
13.8
20
7.3
15
3.3
15
3.0
15
7.3
15
3.3
15
7.3
15
3.3
15
3.0
15
9.4
15
4.3
15
9.4
15
4.3
15
4.8
15
9.4
15
4.3
15
13.3
20
6.0
15
4.8
15
9.4
15
4.3
15
19.0/18.0
30/30
9.0
15
7.0
15
18.0
30
9.0
15
27.5/26.3
45/45
13.1
20
9.5
15
26.3
45
13.1
20
33.0/31.3
55/55
15.6
25
12.0
20
31.3
55
15.6
25
Table 5 — Electrical Data, Alternate Motors
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
FAN MOTOR
V*-PH-HZ
VOLTAGE
LIMITS
Hp
FLA
208/230-1-60
208/230-3-60
460-3-60
575-3-60
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
208/230-3-60
460-3-60
575-3-60
230-3-50
400-3-50
187-253
187-253
414-528
518-632
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
187-253
414-528
518-632
207-253
360-440
2.4
2.9
2.9
2.0
2.9
2.9
3.0
2.9
2.9
2.9
2.9
3.0
2.9
2.9
3.7
3.7
3.0
5.0
5.0
3.7
3.7
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
7.5
7.5
7.5
7.5
7.5
10.0
10.0
10.0
10.0
10.0
11.0
7.5
3.4
2.4
7.5
3.4
3.8
7.5
3.4
7.5
3.4
3.8
7.5
3.4
10.6
4.8
3.8
14.4
7.2
10.6
4.8
5.6
14.4
7.2
15.2/14.4
7.2
5.6
14.4
7.2
22.0/21.0
10.5
7.6
21.0
10.5
26.4/25.0
12.5
9.6
25.0
12.5
UNIT
LEGEND
EXAMPLE: Supply voltage is 400-3-50.
AB = 393 v
BC = 403 v
AC = 396 v
393 + 403 + 396
Average Voltage =
3
1192
=
3
= 397
Determine maximum deviation from average voltage.
(AB) 397 − 393 = 4 v
(BC) 403 − 397 = 6 v
(AC) 397 − 396 = 1 v
Maximum deviation is 6 v.
FLA
— Full Load Amps
MOCP — Maximum Overcurrent Protection
*Motors are designed for satisfactory operation within 10% of nominal voltages shown. Voltages should not exceed the limits shown in
the Voltage Limits column.
NOTES:
1. Minimum Circuit Amp and MOCP values are calculated in
accordance with NEC (National Electrical Code) (U.S.A. standard), Article 440.
2. Motor FLA values are established in accordance with UL (Underwriters’ Laboratories) Standard 1995 (U.S.A. standard).
3. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine
the percentage of voltage imbalance.
Determine percent voltage imbalance.
6
% Voltage Imbalance = 100 x
397
= 1.5%
This amount of phase imbalance is satisfactory as it is below the
maximum allowable 2%.
% Voltage Imbalance
= 100 x
POWER SUPPLY
Minimum
MOCP
Circuit Amps
13.8
20
9.4
15
4.3
15
3.0
15
9.4
15
4.3
15
4.8
15
9.4
15
4.3
15
9.4
15
4.3
15
4.8
15
9.4
15
4.3
15
13.3
20
6.0
15
4.8
15
18.0
30
9.0
15
13.3
20
6.0
15
7.0
15
18.0
30
9.0
15
19.9/18.0
30/30
9.0
15
7.0
15
18.0
30
9.0
15
27.5/26.3
45/45
13.1
20
9.5
15
26.3
45
13.1
20
33.0/31.3
55/55
15.6
25
12.0
20
31.3
55
15.6
25
max voltage deviation from average voltage
average voltage
IMPORTANT: If the supply voltage phase imbalance is more than
2%, contact your local electric utility company immediately.
21
LEGEND
— Circuit Breaker
— Heating Contactor
— Electric Heater
— Indoor-Fan Contactor
— Indoor-Fan Motor
— National Electrical Code
— Terminal Block
— Thermostat
Factory Wiring
Field Control Wiring
NOTE: Use copper conductors only.
CB
HC
HTR
IFC
IFM
NEC
TB
T’STAT
→
Fig. 14 — Unit Wiring
Table 6 — Fan Contactor Coil Data
UNIT
40RM, 40RMQ
40RMS
007-034
VOLTAGE
(vac)
24
MAXIMUM
HOLDING
VA
10
Connecting Ductwork — Refer to the Carrier System Design Manual for the recommended design and layout
of ductwork. Figure 15 shows recommended duct connection to units with 2 fans.
DISCHARGE CONNECTIONS — Duct flanges are factory
supplied; they are shipped inside the unit attached to the hairpin end of the coil tube sheet for field installation. Using the
existing screws, install the duct flanges on the unit’s fan deck.
Each fan discharge requires 2 flanges; each flange must be
bent in the middle to conform to the discharge opening. See
Fig. 16. After flanges are installed, connect them to the supply duct using a canvas connection to prevent vibration. It is
important that this connection be properly fabricated to prevent high air friction losses and air noise.
RETURN CONNECTION — When using return-air ductwork, route return-air duct to the unit’s return air inlet near
the filter rack, using a canvas connection to prevent transmission of unit vibration. If the duct blocks off the unit’s
access panel, provide a slip joint in the ductwork to permit
removal for servicing.
OUTDOOR-AIR INLET CONNECTION — Connect outdoorair inlet to field-installed accessory economizer. Refer to economizer Installation Instructions.
Return-Air Filters — Type and size of filters are
shown in Tables 1A-1F and are factory-supplied and installed. In all units with 2 fans, a filter replacement tool (hook)
is shipped inside the unit for field use when replacing filters.
See the Service section for instructions on filter element
replacement.
596
Fig. 15 — Typical Fan Discharge Connections
for Multiple Fan Units
22
Fig. 16 — Duct Flange Installation
START-UP
Fan Motor Lubrication — Fan motor supplied with
unit is permanently lubricated and requires no further
lubrication.
Before starting unit, check the following and correct as
necessary:
• Is unit solidly supported?
• Is fan adjusted for speed and pulley alignment?
• Are pulleys, motor, and bearings securely mounted?
• Are there any loose parts that will rattle or vibrate?
• Is condensate drain pan pitched for correct drainage?
• Are coil baffle plates tight against coil to prevent air
bypass?
• Are all panels securely fastened?
• Are all electrical connections correct and tight?
Fan Shaft Bearings — Bearings on 007-012 size units
are sealed, permanently lubricated bearings that require no
further lubrication. Size 014-034 units have pillow-block bearings (Fig. 17) that must be lubricated with suitable bearing
grease approximately every 3 months. See Table 7 for suitable lubricants.
Table 7 — Lubricant Data
MANUFACTURER
Sunoco
Texaco
Texaco
Mobil
Also refer to condensing unit instructions before starting
a split system. A split system start-up checklist is provided
in the back of these instructions.
LUBRICANT
Prestige 42
Multifak 2
Regal AFB-2*
Mobilplex EP No. 2
*Preferred lubricant because it contains rust and oxidation
inhibitors.
SERVICE
Inspection and maintenance should be performed at
regular intervals and should include the following:
• Complete cleaning of cabinet, fan wheel, cooling coil, condensate pan and drain, heating coils, and return-air grille
(if present).
• Inspection of panels and sealing of unit against air
leakage.
• Adjustment of fan motor, belt, bearings, and wheels.
• Cleaning or replacement of filters.
• Testing for cooling/heating system leaks.
• Checking of all electrical connections.
Most unit service can be performed by removing one or
both of the unit’s side panels. Coil cleaning or removal or
insulation cleaning may require removal of a rear, top, or
bottom panel, depending on the unit’s orientation. When service is completed, replace unit panels.
Panels — Panels are fastened to unit frame with sheet
metal screws. Fan and coil compartment must be sealed tightly
after service to prevent air from bypassing the cooling coil.
Fig. 17 — Fan Shaft, Bearings, and Fan Wheel
(Typical)
23
Centering Fan Wheel — If fan and fan shaft assem-
Individual Fan Wheel Adjustment — Loosen the
bly are not properly centered, blades may scrape against scroll
or may create an objectionable whistling noise. It may be
necessary to adjust individual fan wheels or move entire fan
shaft. See the following two sections.
2 locking bolts holding fan wheel hub to shaft. See Fig. 17.
Position fan wheel in center of the fan housing and tighten
locking bolts. Clearance between wheel and housing should
be the same on both sides.
Fan Shaft Position Adjustment — Loosen setscrew or locking collar of each fan shaft bearing. Slide shaft
into correct position and replace locking collar (Fig. 18). To
replace locking collar, push collar up against inner face of
bearing. Turn collar in direction of fan rotation until tight,
and tighten setscrew. Tightening locking collar in direction
of fan rotation results in further tightening of collar should
setscrew work itself loose.
Fan Belts — Motor mounting plate and motor support
angles are slotted to permit both vertical and horizontal
adjustment. Adjust belt(s) for correct deflection by loosening motor plate mounting bolts, moving motor/plate assembly forward or back, and retightening bolts. Press down on
belt with one finger midway between fan and motor pulleys
to check deflection. For units with motor sizes up to and
including 3.7 Hp (2.76 kW), correct deflection is 3⁄16-in.
(4.8 mm) For larger motor sizes, correct deflection is 1⁄8-in.
(3.2 mm). See Fig. 19.
NOTE: The 028 and 034 size units with 60 Hz motors are
shipped with an extra set of matching belts. Use the preinstalled belts or extra belts depending on the adjustable
pulley setting.
If complete belt replacement is required during servicing, loosen the motor plate mounting bolts (Fig. 19), move
motor/plate assembly towards fan pulley, and pull belt(s) off
pulleys. Reverse the procedure with new bolts and readjust
deflection.
Fan Rotation — Correct fan rotation with respect to
fan outlet is shown in Fig. 20.
To reverse the direction of rotation of a 3-phase fan motor, reverse any 2 of the power leads. Refer to the connection
diagram on the inside of motor terminal box cover for proper
reversing procedure of single-phase motor.
Fig. 18 — Fan Shaft Bearing
Fig. 19 — Fan Motor Mounting
24
Fig. 20 — Fan Rotation
Fan Pulley Alignment — Align as follows:
1. Loosen setscrews on pulleys.
2. Align pulleys visually and tighten setscrews on fan pulley to lock it in place.
3. Use the methods shown in Fig. 21 to check proper pulley
alignment.
4. If pulleys are not in correct alignment, loosen the motor
holddown bolts and slide the motor axially until the pulleys are aligned.
5. Tighten motor holddown bolts.
Fig. 21 — Fan Pulley Adjustments
Alternative freeze protection methods follow:
• Circulate hot water within the water coil’s supply main or
supplementary space heating.
• Close off supply lines to unit and open a union or fieldsupplied drain valve in the return line.
Pulley and Drive Adjustment — To obtain desired
fan speed, refer to the fan motor and drive data in
Tables 8A-10D and adjust fan motor pulley as follows:
IMPORTANT: Draining from return line will not
completely drain water from coils.
1. Remove belt from fan motor pulley after loosening motor from motor base.
2. Loosen setscrew in moveable flange of pulley. Screw moveable flange toward fixed flange to increase the fan speed
and away from fixed flange to reduce speed. Before tightening setscrew, make certain that setscrew is over nearest
flat surface of pulley hub (Fig. 21).
After draining as much water as possible from coils, add
sufficient antifreeze to prevent residual water in the coil
from freezing.
• Add a sufficient quantity of non-corrosive antifreeze to the
entire system to prevent all water within the system from
freezing.
Coil Removal — Remove unit panels and corner posts
as required. Disconnect coil connections and remove fastening screws. Remove coil through end or side sections of unit.
Increasing fan speed produces a greater load on motor. Do not exceed rated capacity of motor.
Cleaning Cooling Coil — Remove return-air filters.
Remove any heavy dirt that may have accumulated on underside of coil. Coil can be cleaned more easily with a stiff
brush, vacuum cleaner, or compressed air when coil is dry.
If coil is wet or if water is to be used for cleaning, guard
against splashing water on electrical components or damaging surrounding area. Clean coil baffles as applicable and
check for tight fit to be sure air does not bypass coil.
Condensate Drains — Keep condensate drains free of
dirt and foreign matter.
Return-Air Filters — Refer to Replacing Filters section, page 39, for filter accessibility and removal. Replace
with clean filters of the sizes listed in Tables 1A-1F.
Cleaning Insulation — The insulation contains an
Chilled Water Coil Freeze Protection — Shut off
water supply to unit. Remove side panel of unit and remove
vent and drain plugs in top and bottom of coil header. Drain
coil and blow out remaining water. Reinstall plugs and side
panel.
immobilized antimicrobial agent that helps prevent the
growth of bacteria and fungi. Clean the inner surface of the
insulation according to the separate maintenance instructions shipped with the unit.
25
Table 8A — Fan Motor Data, Standard Motor — English
UNIT
40RM
007
208/230-1-60
Speed (rpm)
1725
Hp
1.3
Frame (NEMA)
56Y
5⁄8
Shaft Dia (in.)
208/230-3-60 and 460-3-60
Speed (rpm)
1725
Hp
2.4
Frame (NEMA)
56Y
5⁄8
Shaft Dia (in.)
575-3-60
Speed (rpm)
1725
Hp
1.0
Frame (NEMA)
56
5⁄8
Shaft Dia (in.)
230-3-50 and 400-3-50
Speed (rpm)
1425
Hp
2.4
Frame (NEMA)
56Y
5⁄8
Shaft Dia (in.)
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
1725
2.4
56Y
5 ⁄8
1725
2.4
56Y
5⁄8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1725
2.4
56Y
5 ⁄8
1725
2.4
56Y
5⁄8
1725
2.4
56Y
5 ⁄8
1725
2.9
56Y
7 ⁄8
1725
3.7
56Y
7 ⁄8
1745
5.0
S184T
1 1 ⁄8
1745
7.5
S213T
13⁄8
1745
10.0
S215T
13⁄8
1725
2.0
56HZ
7 ⁄8
1725
2.0
56HZ
7⁄8
1725
2.0
56HZ
7 ⁄8
1725
3.0
56HZ
7 ⁄8
1725
3.0
56HZ
7 ⁄8
1745
5.0
184T
1 1 ⁄8
1755
7.5
S213T
13⁄8
1755
10.0
D215T
13⁄8
1425
2.4
56Y
5 ⁄8
1425
2.4
56Y
5⁄8
1425
2.9
56Y
7 ⁄8
1425
2.9
56Y
7 ⁄8
1425
2.9
56Y
7 ⁄8
1425
5.0
184T
1 1 ⁄8
1425
7.5
S213T
13⁄8
1425
10.0
S215T
13⁄8
NEMA — National Electrical Manufacturers Association
Table 8B — Fan Motor Data, Alternate Motor — English
UNIT
40RM
007
208/230-1-60
Speed (rpm)
1725
Hp
2.4
Frame (NEMA)
56Y
5⁄8
Shaft Dia (in.)
208/230-3-60 and 460-3-60
Speed (rpm)
1725
Hp
2.9
Frame (NEMA)
56Y
7⁄8
Shaft Dia (in.)
575-3-60
Speed (rpm)
1725
Hp
2.0
Frame (NEMA)
56HZ
7⁄8
Shaft Dia (in.)
230-3-50 and 400-3-50
Speed (rpm)
—
Hp
—
Frame (NEMA)
—
Shaft Dia (in.)
—
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1725
2.9
56Y
7 ⁄8
1725
2.9
56Y
7⁄8
1725
3.7
Y56Y
7 ⁄8
1725
3.7
Y56Y
7⁄8
1725
5.0
S184T
11⁄8
1745
7.5
S213T
13⁄8
1745
10.0
S215T
13⁄8
1725
3.0
56HZ
7 ⁄8
1725
3.0
56HZ
7⁄8
1725
3.0
56HZ
7 ⁄8
1745
5.0
184T
1 1 ⁄8
1745
5.0
184T
11⁄8
1755
7.5
S213T
13⁄8
1750
10.0
D215T
13⁄8
1425
2.9
56Y
7 ⁄8
1425
2.9
56Y
7⁄8
1425
5.0
S184T
7 ⁄8
1425
5.0
S184T
1 1 ⁄8
1425
5.0
S184T
11⁄8
1425
7.5
S213T
13⁄8
1425
10.0
S215T
13⁄8
NEMA — National Electrical Manufacturers Association
26
Table 8C — Fan Motor Data, Standard Motor — SI
UNIT
40RM
007
208/230-1-60
Speed (r/s)
28.75
Shaft kW
0.97
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
208/230-3-60 and 460-3-60
Speed (r/s)
28.75
Shaft kW
1.79
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
575-3-60
Speed (r/s)
28.75
Shaft kW
0.746
Frame (NEMA)
56
Shaft Dia (mm)
15.9
230-3-50 and 400-3-50
Speed (r/s)
23.75
Shaft kW
1.79
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
28.75
1.79
56Y
15.9
28.75
1.79
56Y
15.9
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
28.75
1.79
56Y
15.9
28.75
1.79
56Y
15.9
28.75
1.79
56Y
15.9
28.75
2.16
56Y
22.2
28.75
2.76
56Y
22.2
29.08
3.73
S184T
28.6
29.08
5.60
S213T
34.9
29.08
7.46
S215T
34.9
28.75
1.49
56HZ
22.2
28.75
1.49
56HZ
22.2
28.75
1.49
56HZ
22.2
28.75
2.24
56HZ
22.2
28.75
2.24
56HZ
22.2
29.08
3.73
184T
28.6
29.25
5.60
S213T
34.9
29.25
7.46
S215T
34.9
23.75
1.79
56Y
15.9
23.75
1.79
56Y
15.9
23.75
2.16
56Y
22.2
23.75
2.16
56Y
22.2
23.75
2.16
56Y
22.2
23.75
3.73
184T
28.6
23.75
5.60
S213T
34.9
23.75
7.46
S215T
34.9
NEMA — National Electrical Manufacturers Association
Table 8D — Fan Motor Data, Alternate Motor — SI
UNIT
40RM
007
208/230-1-60
Speed (r/s)
28.75
Shaft kW
1.79
Frame (NEMA)
56Y
Shaft Dia (mm)
15.9
208/230-3-60 and 460-3-60
Speed (r/s)
28.75
Shaft kW
2.16
Frame (NEMA)
56Y
Shaft Dia (mm)
22.2
575-3-60
Speed (r/s)
28.75
Shaft kW
1.49
Frame (NEMA)
56HZ
Shaft Dia (mm)
22.2
230-3-50 and 400-3-50
Speed (r/s)
—
Shaft kW
—
Frame (NEMA)
—
Shaft Dia (mm)
—
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
28.75
2.16
56Y
22.2
28.75
2.16
56Y
22.2
28.75
2.76
Y56Y
22.2
28.75
2.76
Y56Y
22.2
29.08
3.73
S184T
28.6
29.08
5.60
S213T
34.9
29.17
7.46
S215T
34.9
28.75
2.24
56HZ
22.2
28.75
2.24
56HZ
22.2
28.75
2.24
56HZ
22.2
29.08
3.73
184T
28.6
29.08
3.73
184T
28.6
29.25
5.60
S213T
34.9
29.17
7.46
D215T
34.9
23.75
2.16
56Y
22.2
23.75
2.16
56Y
22.2
23.75
3.73
S184T
22.2
23.75
3.73
S184T
28.6
23.75
3.73
S184T
28.6
23.75
5.60
S213T
34.9
23.75
7.46
S215T
34.9
NEMA — National Electrical Manufacturers Association
27
Table 9A — Standard Drive Data, 60 Hz — English
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. — Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
2.4-3.4
2.8-3.8
2.8-3.8
3.4-4.4
2.8-3.8
2.8-3.8
3.7-4.7
4.3-5.3
4.3-5.3
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
8.8
1
1—A
8.8
1
1—A
8.8
1
1—A
8.8
1
1—A
9.0
17⁄16
1—A
9.0
17⁄16
1—A
9.4
17⁄16
2—B
40.3
41.3
41.3
42.3
42.3
42.3
41.8
11.0
115⁄16
2—B*
(2) 42.8
(2) 43.8
11.0
115⁄16
2—B*
(2) 42.8
(2) 43.8
568
470-666
1200
647
549-745
1200
647
549-745
1200
764
666-863
1200
632
537-728
1200
632
537-728
1200
771
679-863
1200
752
682-841
1100
752
674-831
1100
19.6
19.6
19.6
19.7
19.1
19.1
15.3
13.1
13.1
5
5
5
5
5
5
6
6
6
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32
9.1210.99
6.679.43
6.679.43
*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.
Table 9B — Medium-Static Drive Data, 60 Hz — English
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. — Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
3.4-4.4
3.4-4.4
3.4-4.4
3.4-4.4
3.4-4.4
3.7-4.7
4.3-5.3
4.3-5.3
4.3-5.3
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
3.0
8.8
1
1—A
8.0
1
1—A
8.0
1
1—A
8.0
1
1—A
8.2
17⁄16
1—A
8.6
17⁄16
1—B
9.4
17⁄16
2—B
42.3
40.3
40.3
40.3
41.3
41.8
41.8
9.4
115⁄16
2—B*
(2) 38.8
(2) 39.8
9.4
115⁄16
2—B*
(2) 38.8
(2) 39.8
764
666-863
1200
841
733-949
1200
841
733-949
1200
841
733-949
1200
820
715-926
1200
842
742-943
1200
881
798-984
1200
881
798-984
1100
881
798-984
1100
19.7
21.6
21.6
21.6
21.1
16.7
15.3
15.3
15.3
5
5
5
5
5
6
6
6
6
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32
9.1610.99
6.679.43
6.679.43
*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.
28
Table 9C — High-Static Drive Data, 60 Hz — English
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. — Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
3.4-4.4
3.4-4.4
3.4-4.4
3.4-4.4
3.7-4.7
4.3-5.3
4.3-5.3
4.3-5.3
4.3-5.3
2.5
2.5
2.5
2.5
3.0
3.0
3.0
3.0
3.0
7.0
1
1—A
41.3
6.0*
1
1—A
37.3
6.0
1
1—A
37.3
6.0
1
1—A
37.3
7.4
17⁄16
1—B
39.8
7.9
17⁄16
1—B
39.8
7.4
17⁄16
2—B
36.8
8.6
115⁄16
2—B
37.8
8.6
115⁄16
2—B
37.8
961
8381084
1200
1121
9781200*†
1200
1121
9781200†
1200
1121
9781200†
1200
979
8731096
1200
1060
9501171
1200
1118
10141200†
1200
1024
8731075
—
1024
8731075
—
24.6
28.7
28.7
28.7
19.4
18.4
19.4
16.7
16.7
5
5
5
5
6
6
6
6
6
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32**
9.1610.99
8.1610.02
6.679.43
6.679.43
*Valves for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 7 in.
and resulting fan speed is 837-1096 rpm.
†It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT
exceed 1200 rpm.
**575-v unit has a center distance of 9.16-10.99.
Table 9D — Standard Drive Data, 50 Hz — English
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. — Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
2.4-3.4
2.8-3.8
2.8-3.8
3.4-4.4
3.4-4.4
3.4-4.4
4.3-5.3
4.3-5.3
4.3-5.3
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
8.0
1
1—A
39.3
8.0
1
1—A
39.3
8.0
1
1—A
39.3
8.0
1
1—A
40.3
9.0
17⁄16
1—A
42.3
9.0
17⁄16
1—A
42.3
8.6
17⁄16
1—B
41.8
11.0
115⁄16
2—B
43.8
11.0
115⁄16
2—B
43.8
517
428-606
1200
588
499-677
1200
588
449-677
1200
695
606-784
1200
618
538-697
1200
618
538-697
1200
795
713-878
1200
622
557-687
1100
622
557-687
1100
17.8
17.8
17.8
17.8
15.9
15.9
13.8
10.8
10.8
5
5
5
5
5
5
6
6
6
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32
9.1210.99
6.679.43
6.679.43
29
Table 9E — Medium-Static Drive Data, 50 Hz — English
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. — Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
3.4-4.4
3.4-4.4
3.4-4.4
3.4-4.4
3.4-4.4
3.7-4.7
4.0-5.0
4.3-5.3
4.3-5.3
2.5
2.5
2.5
2.5
2.5
3.0
2.5
3.0
3.0
8.0
1
1—A
40.3
7.0
1
1—A
41.3
7.0
1
1—A
41.3
6.0
1
1—A
37.3
7.5
17⁄16
1—A
39.3
7.9
17⁄16
1—B
39.8
7.0
17⁄16
2—A
36.8
9.4
115⁄16
2—B
39.8
9.4
115⁄16
2—B
39.8
695
606-784
1200
794
692-896
1200
794
692-896
1200
926
808-1045
1200
741
646-836
1200
756
667-848
1200
916
814-1018
1200
728
652-803
1100
728
652-803
1100
17.8
20.4
20.4
23.7
19.0
15.1
20.4
12.6
12.6
5
5
5
5
5
6
5
6
6
10.4412.32
10.4412.32
10.4412.32
10.4412.32
10.4412.32
9.1610.99
9.1610.99
6.679.43
6.679.43
Table 9F — High-Static Drive Data, 50 Hz — English
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(in.)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (in.)
Pulley Bore (in.)
Belt No. — Section
Belt Pitch (in.)
FAN SPEEDS (rpm)
Factory Setting
Range
Max Allowable Speed (rpm)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(in.)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
3.4-4.4
3.4-4.4
3.4-4.4
4.0-5.0
3.4-4.4
4.0-5.0
4.0-5.0
4.3-5.3
4.3-5.3
2.5
2.5
2.5
3.0
2.5
3.0
3.0
3.0
3.0
6.0
1
1—A
37.3
5.5
1
1—A
37.3
5.5
1
1—A
37.3
5.5
1
1—A
36.3
6.0
17⁄16
2—A
36.3
7.0
17⁄16
2—A
39.3
6.4
17⁄16
2—A
34.3
8.0
115⁄16
2—B
36.8
8.6
115⁄16
2—B
37.8
926
8081045
1200
1010
8811140
1200
1010
8811140
1200
1166
10361200*
1200
926
8081045
1200
916
8141018
1200
1002
8911113
1200
855
766944
1100
795
713878
1100
23.7
25.9
25.9
21.6
23.7
17.0
18.5
14.8
13.8
5
5
5
6
5
6
6
6
6
10.4412.32
10.4412.32
10.4412.32
91610.99
9.1610.99
9.1610.99
8.1610.02
6.679.43
6.679.43
*It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT
exceed 1200 rpm.
30
Table 9G — Standard Drive Data, 60 Hz — SI
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. — Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
61.086.4
71.196.5
71.196.5
86.4111.8
71.196.5
71.196.5
94.0119.4
109.2134.6
109.2134.6
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
224
25.4
1—A
224
25.4
1—A
224
25.4
1—A
224
25.4
1—A
229
36.5
1—A
229
36.5
1—A
239
36.5
2—B
1024
1049
1049
1074
1074
1074
1062
279
49.2
2—B*
(2) 1087
(2) 1113
279
49.2
2—B*
(2) 1087
(2) 1113
9.5
7.8-11.1
20.0
10.8
9.2-12.4
20.0
10.8
9.2-12.4
20.0
12.7
11.1-14.4
20.0
10.5
9.0-12.1
20.0
10.5
9.0-12.1
20.0
12.9
11.3-14.4
20.0
12.5
11.4-14.0
18.3
12.5
11.2-13.9
18.3
0.327
0.327
0.327
0.328
0.318
0.318
0.255
0.218
0.218
5
5
5
5
5
5
6
6
6
265-313
265-313
265-313
265-313
265-313
265-313
232-279
169-240
169-240
*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.
Table 9H — Medium-Static Drive Data, 60 Hz — SI
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. — Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
86.4111.8
86.4111.8
86.4111.8
86.4111.8
86.4111.8
94.0119.4
109.2134.6
109.2134.6
109.2134.6
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
3.0
224
25.4
1—A
203
25.4
1—A
203
25.4
1—A
203
25.4
1—A
208
36.5
1—A
218
36.5
1—B
239
36.5
2—B
1074
1024
1024
1024
1049
1062
1062
239
49.2
2—B*
(2) 986
(2) 1011
239
49.2
2—B*
(2) 986
(2) 1011
12.7
11.114.4
20.0
14.0
12.215.8
20.0
14.0
12.215.8
20.0
14.0
12.215.8
20.0
13.7
11.915.4
20.0
14.0
12.415.7
20.0
14.7
13.316.4
20.0
14.7
13.316.4
18.3
14.7
13.316.4
18.3
0.328
0.360
0.360
0.360
0.352
0.278
0.255
0.255
0.255
5
5
5
5
5
6
6
6
6
265-313
265-313
265-313
265-313
265-313
265-313
232-279
169-240
169-240
*Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting.
31
Table 9I — High-Static Drive Data, 60 Hz — SI
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. — Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
86.4111.8
86.4111.8
86.4111.8
86.4111.8
94.0119.4
109.2
134.6
109.2134.6
109.2134.6
109.2134.6
2.5
2.5
2.5
2.5
3.0
3.0
3.0
3.0
3.0
178
25.4
1—A
1049
152*
25.4
1—A
947
152
25.4
1—A
947
152
25.4
1—A
947
188
36.5
1—B
1011
201
36.5
1—B
1011
188
36.5
2—B
935
203
49.2
2—B
935
203
49.2
2—B
960
16.0
14.018.1
20.0
18.7
16.320.0*†
20.0
18.7
16.320.0†
20.0
18.7
16.320.0†
20.0
16.3
14.418.3
20.0
17.7
15.819.5
20.0
18.6
16.920.0†
20.0
17.1
14.617.9
18.3
17.1
14.617.9
18.3
0.410
0.478
0.478
0.478
0.323
0.307
0.323
0.278
0.278
5
5
5
5
6
6
6
6
6
265-313
265-313
265-313
265-313
265-313**
232-279
207-255
169-240
169-240
*Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 178 mm and
resulting fan speed is 14.0-18.3 r/s.
†It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed
20 r/s.
**575-v unit has a center distance of 233-279.
Table 9J — Standard Drive Data, 50 Hz — SI
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. — Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
61.086.4
71.196.5
71.196.5
86.4111.8
86.4111.8
86.4111.8
109.2134.6
109.2134.6
109.2134.6
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
203
25.4
1—A
998
203
25.4
1—A
998
203
25.4
1—A
998
203
25.4
1—A
1024
229
36.5
1—A
1074
229
36.5
1—A
1074
218
36.5
1—B
1062
279
49.2
2—B
1113
279
49.2
2—B
1113
8.6
7.110.1
20.0
9.8
8.311.3
20.0
9.8
8.311.3
20.0
11.6
10.113.1
20.0
10.3
9.011.6
20.0
10.3
9.011.6
20.0
13.3
11.914.6
20.0
10.4
9.311.5
18.3
10.4
9.311.5
18.3
0.297
0.297
0.297
0.297
0.265
0.265
0.230
0.180
0.180
5
5
5
5
5
5
6
6
6
265-313
265-313
265-313
265-313
265-313
265-313
232-279
169-240
169-240
32
Table 9K — Medium-Static Drive Data, 50 Hz — SI
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. — Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
86.4111.8
86.4111.8
86.4111.8
86.4111.8
86.4111.8
94.0119.4
101.6127.0
109.2134.6
109.2134.6
2.5
2.5
2.5
2.5
2.5
3.0
2.5
3.0
3.0
203
25.4
1—A
1024
178
25.4
1—A
1049
178
25.4
1—A
1049
152
25.4
1—A
947
191
36.5
1—A
998
201
36.5
1—B
1011
178
36.5
2—A
922
239
49.2
2—B
1011
239
49.2
2—B
1011
11.6
10.113.1
20.0
13.2
11.514.9
20.0
13.2
11.514.9
20.0
15.4
13.517.4
20.0
12.4
10.813.9
20.0
12.6
11.114.1
20.0
15.3
13.617.0
20.0
12.1
10.913.4
18.3
12.1
10.913.4
18.3
0.297
0.340
0.340
0.395
0.317
0.252
0.340
0.210
0.210
5
5
5
5
5
6
5
6
6
265-313
265-313
265-313
265-313
265-313
232-279
232-279
169-240
169-240
Table 9L — High-Static Drive Data, 50 Hz — SI
UNIT
MOTOR DRIVE
Motor Pulley Pitch Diameter
(mm)
Pulley Factory Setting
Full Turns Open
FAN DRIVE
Pulley Pitch Dia (mm)
Pulley Bore (mm)
Belt No. — Section
Belt Pitch (mm)
FAN SPEEDS (r/s)
Factory Setting
Range
Max Allowable Speed (r/s)
Change per 1⁄2 Turn of
Moveable Motor Pulley
Flange
MAX FULL TURNS FROM
CLOSED POSITION
SHAFTS CENTER DISTANCE
(mm)
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
86.4111.8
86.4111.8
86.4111.8
101.6127.0
86.4111.8
101.6127.0
101.6127.0
109.2134.6
109.2134.6
2.5
2.5
2.5
3.0
2.5
3.0
3.0
3.0
3.0
152
25.4
1—A
947
140
25.4
1—A
947
140
25.4
1—A
947
140
25.4
1—A
922
152
36.5
2—A
922
178
36.5
2—A
998
163
36.5
2—A
871
203
49.2
2—B
935
218
49.2
2—B
960
15.4
13.517.4
20.0
16.8
14.719.0
20.0
16.8
14.719.0
20.0
19.4
17.320.0*
20.0
15.4
13.517.4
20.0
15.3
13.617.0
20.0
16.7
14.918.6
20.0
14.3
12.815.7
18.3
13.3
11.914.6
18.3
0.395
0.432
0.432
0.360
0.395
0.283
0.308
0.247
0.230
5
5
5
6
5
6
6
6
6
265-313
265-313
265-313
234-279
232-279
232-279
207-255
169-240
169-240
*It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT
exceed 20 r/s.
33
Table 10A — Fan Performance Data — 0.0-1.2 in. wg ESP — English
UNIT
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMS
012
40RMQ
012
40RM
40RMS
014
40RM
40RMS
016
40RMQ
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
AIRFLOW
(Cfm)
1,800
2,100
2,400
2,700
3,000
2,250
2,600
3,000
3,400
3,750
2,550
2,975
3,400
3,825
4,250
3,000
3,500
4,000
4,500
5,000
3,000
3,500
4,000
4,500
5,000
3,750
4,300
5,000
5,700
6,250
4,500
5,300
6,000
6,800
7,500
4,500
5,300
6,000
6,800
7,500
6,000
7,000
8,000
9,000
10,000
7,500
8,750
10,000
11,250
12,500
9,000
10,500
12,000
13,500
15,000
0.0
Rpm
Bhp
320
0.22
373
0.31
427
0.42
480
0.54
533
0.69
359
0.32
415
0.45
478
0.62
542
0.82
598
1.03
396
0.42
462
0.60
527
0.80
593
1.05
659
1.33
444
0.58
518
0.82
592
1.11
666
1.44
740
1.83
471
0.61
550
0.87
628
1.17
706
1.53
785
1.93
363
0.37
416
0.53
484
0.81
552
1.17
605
1.51
391
0.51
460
0.80
521
1.13
590
1.60
651
2.10
405
0.54
476
0.85
539
1.20
611
1.69
674
2.22
503
1.07
586
1.64
670
2.37
754
3.28
838
4.39
412
1.15
481
1.76
549
2.55
618
3.52
687
4.71
471
1.78
550
2.72
628
3.93
707
5.44
785
7.27
0.2
Rpm
Bhp
442
0.32
483
0.42
526
0.53
570
0.67
616
0.82
472
0.44
516
0.57
569
0.75
624
0.95
673
1.17
502
0.54
556
0.72
612
0.93
670
1.18
729
1.47
541
0.71
604
0.95
669
1.25
735
1.59
803
1.98
564
0.74
632
1.00
701
1.31
772
1.67
845
2.08
475
0.58
517
0.78
573
1.08
631
1.47
678
1.83
495
0.75
551
1.08
602
1.43
663
1.93
718
2.45
507
0.79
566
1.13
620
1.50
683
2.03
740
2.58
587
1.37
660
1.98
735
2.74
812
3.69
891
4.83
492
1.53
550
2.17
610
2.99
672
4.00
735
5.22
539
2.17
608
3.15
679
4.40
752
5.94
826
7.81
EXTERNAL STATIC PRESSURE (in. wg)
0.4
0.6
0.8
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
534
0.42
611
0.52
678
0.61
569
0.53
642
0.63
708
0.73
606
0.64
676
0.75
739
0.86
646
0.78
712
0.89
773
1.00
687
0.94
750
1.05
808
1.16
560
0.55
634
0.65
700
0.75
599
0.68
669
0.79
732
0.90
645
0.86
712
0.98
773
1.09
695
1.08
758
1.20
815
1.31
740
1.29
800
1.42
855
1.60
586
0.65
658
0.76
722
0.87
634
0.84
701
0.95
762
1.06
684
1.06
748
1.18
806
1.30
737
1.31
797
1.44
852
1.56
791
1.60
848
1.73
901
1.86
621
0.83
691
0.94
753
1.05
677
1.08
742
1.20
801
1.32
736
1.38
797
1.51
853
1.63
797
1.72
854
1.86
907
1.99
861
2.12
914
2.26
964
2.39
642
0.86
710
0.97
771
1.09
703
1.13
766
1.25
824
1.37
766
1.44
825
1.57
879
1.69
832
1.81
887
1.94
938
2.07
900
2.22
952
2.36
1000
2.50
566
0.80
645
1.02
715
1.24
601
1.02
676
1.26
743
1.50
650
1.35
719
1.62
782
1.89
702
1.76
766
2.06
826
2.36
744
2.15
805
2.47
862
2.79
581
1.00
657
1.25
725
1.50
629
1.35
700
1.63
764
1.91
675
1.73
741
2.04
801
2.34
730
2.26
791
2.59
847
2.92
779
2.81
837
3.16
890
3.52
592
1.03
667
1.28
735
1.54
643
1.40
713
1.68
776
1.97
691
1.81
756
2.11
816
2.42
748
2.36
809
2.69
865
3.03
800
2.93
857
3.29
910
3.65
661
1.67
727
1.97
789
2.28
726
2.31
787
2.65
844
2.99
795
3.12
851
3.49
904
3.86
867
4.09
918
4.50
967
4.90
941
5.27
988
5.70
1034
6.14
568
2.00
640
2.56
710
3.22
616
2.66
680
3.22
742
3.86
669
3.50
726
4.07
782
4.70
725
4.53
777
5.12
827
5.76
783
5.78
830
6.38
876
7.04
604
2.63
667
3.17
728
3.78
665
3.64
720
4.18
774
4.79
730
4.92
779
5.48
827
6.09
797
6.49
841
7.08
885
7.71
867
8.39
907
9.01
947
9.66
See Legend and Notes on page 36.
34
1.0
Rpm
739
767
796
828
862
759
790
828
869
906
780
818
860
904
950
809
855
904
956
1010
827
877
930
987
1045
779
805
841
881
915
787
823
858
901
941
797
835
872
918
960
846
898
954
1014
1077
776
802
836
876
922
788
827
874
928
986
Bhp
0.70
0.82
0.96
1.11
1.28
0.86
1.01
1.20
1.43
1.66
0.97
1.18
1.41
1.68
1.98
1.17
1.44
1.75
2.12
2.53
1.20
1.49
1.82
2.20
2.63
1.47
1.74
2.16
2.66
3.11
1.76
2.20
2.65
3.26
3.88
1.80
2.26
2.73
3.37
4.02
2.59
3.33
4.23
5.31
6.85
3.98
4.58
5.40
6.45
7.74
4.46
5.45
6.76
8.38
10.35
1.2
Rpm
795
821
849
880
912
814
843
879
918
954
833
870
910
952
997
862
906
953
1003
1055
878
926
978
1032
1089
839
862
896
934
966
845
878
911
951
990
854
890
924
968
1008
900
948
1001
1059
1120
840
860
889
925
966
845
878
921
970
1024
Bhp
0.80
0.92
1.06
1.21
1.39
0.96
1.11
1.32
1.55
1.78
1.08
1.29
1.53
1.80
2.11
1.28
1.56
1.88
2.24
2.66
1.31
1.60
1.94
2.33
2.76
1.69
1.99
2.44
2.96
3.43
2.02
2.48
2.96
3.60
4.24
2.06
2.55
3.05
3.71
4.38
2.90
3.67
4.61
5.72
7.02
4.83
5.38
6.17
7.21
8.49
5.22
6.18
7.47
9.10
11.07
Table 10B — Fan Performance Data — 1.4-2.4 in. wg ESP — English
UNIT
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMS
012
40RMQ
012
40RM
40RMS
014
40RM
40RMS
016
40RMQ
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
AIRFLOW
(Cfm)
1,800
2,100
2,400
2,700
3,000
2,250
2,600
3,000
3,400
3,750
2,550
2,975
3,400
3,825
4,250
3,000
3,500
4,000
4,500
5,000
3,000
3,500
4,000
4,500
5,000
3,750
4,300
5,000
5,700
6,250
4,500
5,300
6,000
6,800
7,500
4,500
5,300
6,000
6,800
7,500
6,000
7,000
8,000
9,000
10,000
7,500
8,750
10,000
11,250
12,500
9,000
10,500
12,000
13,500
15,000
1.4
Rpm
847
872
899
928
959
865
893
928
965
1000
884
919
957
998
1041
911
953
999
1047
1097
927
973
1023
1075
1130
894
916
948
984
1014
899
930
961
999
1036
908
941
974
1015
1054
950
996
1047
1102
1160
903
917
941
972
1010
901
928
966
1011
1062
1.6
Bhp
0.89
1.02
1.16
1.32
1.49
1.06
1.22
1.43
1.66
1.90
1.18
1.40
1.64
1.92
2.23
1.39
1.67
2.00
2.37
2.79
1.43
1.72
2.06
2.45
2.90
1.91
2.23
2.71
3.25
3.75
2.29
2.78
3.28
3.94
4.60
2.33
2.84
3.36
4.05
4.75
3.21
4.02
4.99
6.13
7.46
5.79
6.26
7.01
8.02
9.29
6.07
6.98
8.24
9.86
11.84
Rpm
896
920
946
974
1004
913
940
973
1010
1043
931
965
1002
1041
1083
958
998
1042
1089
1138
973
1018
1066
1116
1170
947
967
997
1031
1060
951
980
1009
1045
1080
959
991
1022
1061
1098
999
1042
1091
1143
1200
963
972
991
1019
1053
955
978
1011
1052
—
EXTERNAL STATIC PRESSURE (in. wg)
1.8
2.0
Bhp
Rpm
Bhp
Rpm
Bhp
0.98
942
1.07
986
1.16
1.11
965
1.21
1008
1.30
1.26
990
1.36
1033
1.46
1.42
1018
1.52
1059
1.63
1.60
1046
1.71
1087
1.81
1.16
958
1.27
1001
1.37
1.33
984
1.43
1027
1.54
1.54
1017
1.65
1058
1.76
1.78
1052
1.89
1092
2.00
2.02
1084
2.13
1124
2.25
1.29
975
1.40
1018
1.50
1.51
1009
1.62
1050
1.73
1.76
1044
1.87
1085
1.98
2.04
1082
2.16
1122
2.27
2.35
1123
2.48
1161
2.60
1.50
1002
1.61
1044
1.72
1.79
1041
1.90
1082
2.02
2.12
1084
2.24
1124
2.36
2.50
1129
2.62
1168
2.74
2.92
1177
3.05
—
—
1.54
1017
1.65
1058
1.76
1.84
1060
1.95
1101
2.07
2.19
1107
2.31
1146
2.43
2.58
1156
2.71
1194
2.83
3.03
—
—
—
—
2.14
996
2.37
1044
2.60
2.48
1016
2.73
1062
2.98
2.98
1044
3.26
1089
3.53
3.55
1076
3.86
1120
4.16
4.07
1104
4.39
1147
4.71
2.56
999
2.84
1046
3.12
3.08
1027
3.38
1072
3.68
3.60
1055
3.92
1098
4.24
4.28
1089
4.63
1132
4.98
4.97
1123
5.34
1164
5.71
2.61
1008
2.89
1054
3.17
3.14
1038
3.45
1082
3.75
3.69
1067
4.01
1111
4.34
4.40
1104
4.75
1146
5.10
5.12
1140
5.49
1181
5.86
3.53
1045
3.85
1089
4.17
4.37
1086
4.72
1129
5.07
5.37
1133
5.75
1173
6.13
6.54
1183
6.96
—
—
7.91
—
—
—
—
6.83
1021
7.98
1078
9.21
7.22
1025
8.26
1078
9.38
7.91
1040
8.89
1089
9.93
8.89
1064
9.83
—
—
10.15
1095
11.05
—
—
6.98
1008
7.98
1060
9.05
7.84
1026
8.76
1073
9.74
9.07
1055
9.95
1098
10.88
10.67
1092
11.52
—
—
—
—
—
—
—
See Legend and Notes on page 36.
35
2.2
Rpm
1027
1050
1073
1099
1126
1042
1067
1098
1131
1162
1059
1090
1124
1160
1199
1084
1122
1162
—
—
1098
1139
1184
—
—
1089
1107
1133
1162
1188
1091
1116
1141
1173
—
1098
1126
1153
1187
—
1131
1169
—
—
—
—
—
—
—
—
—
—
—
—
—
2.4
Bhp
1.25
1.40
1.55
1.73
1.92
1.47
1.65
1.87
2.12
2.37
1.61
1.84
2.10
2.39
2.72
1.83
2.13
2.48
—
—
1.87
2.18
2.55
—
—
2.83
3.24
3.81
4.46
5.03
3.41
3.99
4.57
5.33
—
3.46
4.06
4.67
5.46
—
4.50
5.43
—
—
—
—
—
—
—
—
—
—
—
—
—
Rpm
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1123
1159
1199
—
—
1137
1177
—
—
—
—
—
—
—
—
1133
1157
1181
—
—
1141
1167
1193
—
—
1172
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bhp
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.94
2.25
2.60
—
—
1.98
2.30
—
—
—
—
—
—
—
—
3.70
4.30
4.91
—
—
3.75
4.38
5.00
—
—
4.83
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Legend and Notes for Table 10A and 10B
LEGEND
Bhp — Brake Horsepower Input to Fan
ESP — External Static Pressure
Factory-Supplied Filter Pressure Drop — English
40RM
007
AIRFLOW
(Cfm)
1,800
2,400
3,000
PRESSURE DROP
(in. wg)
0.05
0.08
0.11
40RM
40RMQ
40RMS
008
2,250
3,000
3,750
0.07
0.11
0.15
40RMS
010
2,550
3,400
4,250
0.09
0.13
0.18
3,000
4,000
5,000
0.11
0.17
0.23
3,750
5,000
6,250
0.06
0.10
0.13
4,500
6,000
7,500
0.08
0.12
0.17
6,000
8,000
10,000
7,500
10,000
12,500
9,000
12,000
15,000
0.12
0.19
0.26
0.15
0.22
0.30
0.19
0.29
0.40
UNIT
NOTES:
1. Maximum allowable fan speed is 1100 rpm for unit sizes 028 and
034; 1200 rpm for all other sizes.
2. Fan performance is based on deductions for wet coil, clean 2-in.
filters, and unit casing. See right for factory-supplied filter pressure drop.
3. Refer to fan motor and drive tables for additional data.
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
36
Table 10C — Fan Performance Data — 0-300 Pa ESP — SI
UNIT
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMS
012
40RMQ
012
40RM
40RMS
014
40RM
40RMS
016
40RMQ
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
AIRFLOW
(L/s)
850
1000
1150
1300
1450
1000
1200
1400
1600
1800
1200
1400
1600
1800
2000
1450
1670
1900
2120
2350
1450
1670
1900
2120
2350
1750
2050
2350
2650
2950
2100
2450
2800
3150
3500
2100
2450
2800
3150
3500
2900
3350
3800
4250
4700
3500
4100
4700
5300
5900
4250
4950
5650
6350
7050
0
r/s
5.34
6.28
7.22
8.17
9.11
5.63
6.76
7.89
9.01
10.10
6.58
7.67
8.77
9.86
11.0
7.58
8.73
9.93
11.10
12.30
8.04
9.26
10.50
11.80
13.00
5.99
7.01
8.04
9.07
10.10
6.43
7.51
8.58
9.65
10.70
6.65
7.76
8.87
9.98
11.10
8.58
9.91
11.30
12.60
13.90
6.79
7.95
9.12
10.30
11.40
7.86
9.15
10.40
11.70
13.00
50
kW
0.17
0.24
0.33
0.43
0.55
0.22
0.32
0.46
0.62
0.80
0.31
0.44
0.60
0.78
0.99
0.46
0.63
0.84
1.08
1.36
0.49
0.67
0.89
1.14
1.43
0.27
0.41
0.60
0.84
1.13
0.37
0.57
0.82
1.14
1.52
0.39
0.60
0.86
1.19
1.59
0.86
1.28
1.81
2.46
3.24
0.84
1.29
1.88
2.62
3.52
1.33
2.03
2.92
4.02
5.37
r/s
7.38
8.10
8.86
9.64
10.50
7.61
8.49
9.42
10.40
11.40
8.35
9.25
10.20
11.10
12.10
9.18
10.20
11.20
12.20
13.30
9.57
10.60
11.80
12.90
14.00
7.88
8.68
9.53
10.40
11.30
8.19
9.06
9.96
10.90
11.90
8.39
9.30
10.20
11.20
12.20
9.96
11.10
12.30
13.60
14.80
8.14
9.12
10.10
11.20
12.30
8.99
10.10
11.30
12.50
13.70
kW
0.25
0.32
0.41
0.52
0.64
0.30
0.41
0.55
0.71
0.90
0.40
0.54
0.70
0.88
1.09
0.56
0.73
0.95
1.18
1.17
0.58
0.77
0.99
1.24
1.54
0.43
0.60
0.81
1.06
1.37
0.55
0.77
1.05
1.38
1.78
0.58
0.81
1.09
1.44
1.86
1.09
1.53
2.09
2.76
3.57
1.12
1.60
2.21
3.00
3.90
1.63
2.35
3.27
4.40
5.77
EXTERNAL STATIC PRESSURE (Pa)
100
150
200
r/s
kW
r/s
kW
r/s
kW
8.91
0.32
10.20
0.39
11.30
0.46
9.53
0.40
10.80
0.48
11.80
0.55
10.20
0.50
11.40
0.58
12.40
0.66
10.90
0.61
12.00
0.69
13.00
0.77
11.60
0.73
12.70
0.82
13.60
0.91
9.11
0.38
10.40
0.45
11.50
0.53
9.88
0.50
11.10
0.57
12.10
0.66
10.70
0.64
11.80
0.72
12.80
0.81
11.60
0.80
12.60
0.89
13.60
0.98
12.50
0.10
13.50
1.09
14.40
1.18
9.76
0.49
11.00
0.57
12.00
0.65
10.60
0.63
11.70
0.71
12.70
0.80
11.40
0.79
12.50
0.88
13.40
0.97
12.30
0.98
13.30
1.07
14.20
1.16
13.20
1.19
14.10
1.29
15.00
3.38
10.50
0.65
11.60
0.73
12.70
0.82
11.40
0.83
12.50
0.92
13.40
1.01
12.30
1.05
13.30
1.14
14.30
1.24
13.30
1.29
14.20
1.39
15.10
1.48
14.30
1.57
15.20
1.68
16.00
1.78
10.90
0.67
12.00
0.76
13.00
0.85
11.80
0.86
12.90
0.95
13.80
1.04
12.80
1.09
13.80
1.19
14.70
1.28
13.90
1.35
14.80
1.45
15.60
1.55
15.00
1.65
15.80
1.75
16.60
1.85
9.41
0.59
10.70
0.75
11.90
0.92
10.10
0.78
11.30
0.96
12.40
1.14
10.80
1.01
12.00
1.21
13.00
1.41
11.60
1.28
12.70
1.50
13.70
1.72
12.40
1.61
13.40
1.85
14.40
2.08
9.65
0.73
10.90
0.92
12.10
1.11
10.40
0.97
11.60
1.18
12.70
1.39
11.20
1.27
12.30
1.49
13.30
1.72
12.00
1.63
13.10
1.87
14.00
2.12
12.90
2.05
13.90
2.31
14.80
2.58
9.83
0.76
11.10
0.95
12.20
1.13
10.60
1.01
11.80
1.22
12.90
1.43
11.50
1.32
12.50
1.55
13.60
1.78
12.30
1.70
13.40
1.95
14.30
2.20
13.20
2.14
14.20
2.41
15.10
2.68
11.20
1.32
12.30
1.55
13.30
1.78
12.20
1.79
13.20
2.04
14.20
2.30
13.30
2.37
14.30
2.64
15.10
2.93
14.50
3.07
15.30
3.37
16.10
3.67
15.60
3.90
16.40
4.22
17.20
4.55
9.42
1.47
10.70
1.89
11.80
2.39
10.20
1.96
11.30
2.38
12.40
2.86
11.10
2.59
12.10
3.02
13.00
3.49
12.10
3.37
12.90
3.81
13.80
4.29
13.10
4.32
13.90
4.77
14.60
5.26
10.10
1.97
11.10
2.37
12.20
2.83
11.10
2.72
12.00
3.12
12.90
3.58
12.20
3.66
13.00
4.08
13.80
4.54
13.30
4.81
14.00
5.25
14.70
5.72
14.40
6.21
15.10
6.66
15.70
7.15
See Legend and Notes on page 39.
37
250
r/s
kW
12.30
0.53
12.80
0.63
13.40
0.73
13.90
0.85
14.50
0.99
12.50
0.61
13.10
0.74
13.80
0.89
14.50
1.07
15.20
1.27
13.00
0.73
13.60
0.88
14.30
1.05
15.10
1.25
15.80
1.48
13.60
0.90
14.30
1.10
15.10
1.33
15.90
1.58
16.80
1.88
13.90
0.93
14.70
1.13
15.60
1.38
16.40
1.64
17.40
1.95
13.00
1.08
13.50
1.33
14.00
1.61
14.60
1.94
15.30
2.32
13.10
1.30
13.70
1.60
14.30
1.95
14.90
2.36
15.60
2.84
13.30
1.31
13.80
1.63
14.50
2.01
15.20
2.45
15.90
2.95
14.20
2.01
15.10
2.55
16.00
3.21
16.90
3.98
17.90
4.88
12.90
2.96
13.40
3.40
13.90
4.02
14.60
4.82
15.40
5.79
13.20
3.34
13.80
4.08
14.60
5.04
15.50
6.23
16.40
7.67
300
r/s
kW
13.30
0.60
13.70
0.70
14.20
0.81
14.80
0.93
15.40
1.07
13.40
0.68
14.00
0.82
14.60
0.97
15.30
1.16
16.00
1.36
13.90
0.81
14.50
0.96
15.20
1.14
15.90
1.34
16.60
1.57
14.50
0.99
15.20
1.18
15.90
1.42
16.70
1.68
17.60
1.98
14.80
1.02
15.50
1.22
16.40
1.47
17.20
1.74
18.10
2.05
14.00
1.25
14.40
1.51
14.90
1.82
15.50
2.16
16.10
2.56
14.10
1.50
14.60
1.81
15.10
2.18
15.80
2.61
16.40
3.11
14.20
1.50
14.80
1.84
15.40
2.24
16.00
2.70
16.70
3.22
15.10
2.25
15.90
2.81
16.80
3.49
17.70
4.28
18.60
5.21
14.00
3.61
14.30
4.00
14.80
4.60
15.40
5.38
16.10
6.35
14.10
3.92
14.70
4.62
15.40
5.57
16.20
6.77
17.10
8.21
Table 10D — Fan Performance Data — 350-600 Pa ESP — SI
UNIT
40RM
007
40RM
40RMQ
40RMS
008
40RMS
010
40RM
40RMS
012
40RMQ
012
40RM
40RMS
014
40RM
40RMS
016
40RMQ
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
AIRFLOW
(L/s)
850
1000
1150
1300
1450
1000
1200
1400
1600
1800
1200
1400
1600
1800
2000
1450
1670
1900
2120
2350
1450
1670
1900
2120
2350
1750
2050
2350
2650
2950
2100
2450
2800
3150
3500
2100
2450
2800
3150
3500
2900
3350
3800
4250
4700
3500
4100
4700
5300
5900
4250
4950
5650
6350
7050
350
r/s
14.10
14.60
15.10
15.60
16.10
14.30
14.80
15.40
16.10
16.80
14.70
15.30
16.00
16.60
17.30
15.30
16.00
16.70
17.50
18.30
15.60
16.30
17.10
17.90
18.80
14.90
15.30
15.80
16.30
16.90
15.00
15.50
16.00
16.60
17.20
15.10
15.60
16.20
16.80
17.50
16.00
16.70
17.50
18.40
19.30
15.10
15.30
15.70
16.20
16.90
15.00
15.50
16.10
16.90
17.70
400
kW
0.67
0.77
0.88
1.01
1.15
0.76
0.90
1.06
1.24
1.45
0.89
1.05
1.23
1.43
1.66
1.07
1.27
1.51
1.77
2.07
1.10
1.31
1.56
1.83
2.15
1.42
1.70
2.02
2.39
2.80
1.70
2.03
2.42
2.87
3.38
1.68
2.05
2.47
2.95
3.49
2.49
3.08
3.77
4.59
5.54
4.33
4.67
5.23
5.99
6.95
4.55
5.22
6.16
7.34
8.79
r/s
15.00
15.40
15.90
16.40
16.90
15.10
15.60
16.20
16.80
17.50
15.50
16.10
16.70
17.40
18.00
16.10
16.70
17.40
18.20
19.00
16.30
17.00
17.80
18.60
19.50
15.80
16.20
16.60
17.10
17.70
15.80
16.30
16.80
17.40
18.00
16.00
16.40
17.00
17.60
18.20
16.80
17.50
18.20
19.10
20.00
16.10
16.20
16.50
17.00
17.60
16.00
16.30
16.90
17.50
18.30
kW
0.74
0.84
0.96
1.09
1.24
0.83
0.98
1.14
1.33
1.54
0.97
1.13
1.31
1.52
1.76
1.15
1.36
1.60
1.86
2.17
1.18
1.40
1.65
1.93
2.25
1.58
1.88
2.22
2.61
3.04
1.90
2.25
2.66
3.12
3.65
1.87
2.25
2.69
3.19
3.76
2.73
3.34
4.06
4.90
5.87
5.12
5.39
5.91
6.65
7.59
5.24
5.86
6.77
7.94
9.39
EXTERNAL STATIC
450
r/s
kW
15.70
0.81
16.10
0.91
16.60
1.03
17.10
1.17
17.60
1.32
15.80
0.91
16.40
1.05
16.90
1.22
17.50
1.41
18.20
1.63
16.30
1.05
16.80
1.21
17.40
1.40
18.10
1.61
18.70
1.85
16.80
1.24
17.40
1.44
18.10
1.69
18.80
1.96
19.60
2.27
17.10
1.27
17.80
1.48
18.50
1.74
19.30
2.02
—
—
16.60
1.75
17.00
2.07
17.40
2.43
17.90
2.83
18.40
3.28
16.70
2.11
17.10
2.47
17.60
2.90
18.10
3.38
18.70
3.93
16.80
2.06
17.20
2.46
17.80
2.92
18.30
3.44
19.00
4.03
17.50
2.97
18.20
3.61
18.90
4.35
19.80
5.21
—
—
17.10
5.98
17.10
6.18
17.40
6.64
17.80
7.35
18.30
8.27
16.80
5.99
17.10
6.56
17.60
7.43
18.20
8.58
—
—
See Legend and Notes on page 39.
38
PRESSURE (Pa)
500
r/s
kW
16.50
0.87
16.90
0.98
17.30
1.11
17.80
1.25
18.30
1.40
16.60
0.99
17.10
1.13
17.60
1.30
18.20
1.50
18.90
1.72
17.00
1.12
17.50
1.29
18.10
1.48
18.70
1.70
19.40
1.94
17.50
1.32
18.10
1.53
18.80
1.78
19.50
2.05
—
—
17.80
1.35
18.40
1.57
19.20
1.83
19.90
2.11
—
—
17.40
1.93
17.80
2.26
18.20
2.64
18.60
3.06
19.10
3.53
17.40
2.32
17.80
2.70
18.30
3.14
18.80
3.64
19.40
4.20
17.50
2.24
18.00
2.67
18.50
3.15
19.00
3.69
19.60
4.30
18.30
3.22
18.90
3.87
19.60
4.64
—
—
—
—
18.00
6.92
18.00
7.02
18.20
7.43
—
—
—
—
17.70
6.79
17.90
7.30
18.30
8.13
—
—
—
—
550
r/s
17.20
17.60
18.00
18.40
18.90
17.30
17.80
18.30
18.90
19.50
17.70
18.20
18.80
19.40
—
18.20
18.80
19.40
—
—
18.40
19.10
19.80
—
—
18.20
18.50
18.90
19.30
19.80
18.20
18.60
19.00
19.50
—
18.30
18.70
19.20
19.70
—
19.00
19.60
—
—
—
—
—
—
—
—
—
—
—
—
—
kW
0.94
1.06
1.18
1.32
1.48
1.06
1.21
1.39
1.58
1.80
1.20
1.37
1.57
1.79
—
1.40
1.62
1.87
—
—
1.43
1.66
1.92
—
—
2.10
2.45
2.84
3.28
3.77
2.53
2.93
3.38
3.90
—
2.43
2.88
3.38
3.94
—
3.47
4.14
—
—
—
—
—
—
—
—
—
—
—
—
—
600
r/s
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
18.80
19.40
—
—
—
19.10
19.70
—
—
—
—
—
—
—
—
18.90
19.30
19.70
—
—
19.00
19.40
19.80
—
—
19.70
—
—
—
—
—
—
—
—
—
—
—
—
—
—
kW
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.48
1.70
—
—
—
1.52
1.74
—
—
—
—
—
—
—
—
2.74
3.16
3.63
—
—
2.62
3.09
3.61
—
—
3.72
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Legend and Notes for Tables 10C and 10D
Replacing Filters — Filters can be removed and installed from either side of the unit. Install new filters in units
that have one fan as follows:
1. Remove the side access panel (retain screws).
2. Remove the filter retainer clip.
3. Remove old filters by tilting them and lifting them out of
the filter track. See Fig. 12 and 22.
4. Reverse the procedure to install new filters.
LEGEND
ESP — External Static Pressure
NOTES:
1. Maximum allowable fan speed is 18.3 r/s for unit sizes 028 and
034; 20 r/s for all other sizes.
2. Fan performance is based on deductions for wet coil, clean 51-mm
filters, and unit casing. See right for factory-supplied filter pressure drop.
3. Refer to fan motor and drive tables for additional data.
To install new filters in larger units that have 2 fans, follow the preceding steps, but use the factory-supplied
filter hook to slide filters within reach for removal. The
filter hook is shipped inside the unit in the baserail.
Factory-Supplied Filter Pressure Drop — SI
40RM
007
AIRFLOW
(L/s)
850
1150
1450
PRESSURE DROP
(Pa)
13
20
28
40RM
40RMQ
40RMS
008
1000
1400
1800
17
27
38
40RMS
010
1200
1600
2000
21
32
45
1450
1900
2350
28
42
56
1750
2350
2950
15
24
33
2100
2800
3500
20
30
42
2900
3800
4700
3500
4700
5900
4250
5650
7050
32
47
64
36
55
76
47
71
98
UNIT
40RM
40RMQ
40RMS
012
40RM
40RMS
014
40RM
40RMQ
40RMS
016
40RM
40RMS
024
40RM
40RMS
028
40RM
40RMS
034
Do not operate unit without air filters.
Fig. 22 — Filter Removal/Replacement
39
Copyright 1995 Carrier Corporation
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 111
Catalog No. 534-053
Printed in U.S.A.
Form 40RM-9SI
Pg 42
596
11-95
Replaces: 40RM-1SI
Tab 3c 2e
CUT ALONG DOTTED LINE
CUT ALONG DOTTED LINE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
START-UP CHECKLIST
(SPLIT SYSTEMS WITH 40RM/RMQ/RMS UNITS)
A. Preliminary Information
OUTDOOR: MODEL NO.
SERIAL NO.
INDOOR: MODEL NO.
SERIAL NO.
ADDITIONAL ACCESSORIES
B. Pre-Start-Up
OUTDOOR UNIT
(Y/N)
IS THERE ANY SHIPPING DAMAGE?
IF SO, WHERE:
WILL THIS DAMAGE PREVENT UNIT START-UP?
(Y/N)
CHECK POWER SUPPLY. DOES IT AGREE WITH UNIT?
HAS THE GROUND WIRE BEEN CONNECTED?
(Y/N)
(Y/N)
HAS THE CIRCUIT PROTECTION BEEN SIZED AND INSTALLED PROPERLY?
(Y/N)
ARE THE POWER WIRES TO THE UNIT SIZED AND INSTALLED PROPERLY?
(Y/N)
HAVE COMPRESSOR HOLDDOWN BOLTS BEEN LOOSENED?
(Y/N)
CONTROLS
ARE THERMOSTAT(S) AND INDOOR FAN CONTROL WIRING
CONNECTIONS MADE AND CHECKED?
(Y/N)
ARE ALL WIRING TERMINALS (including main power supply) TIGHT?
(Y/N)
HAVE OUTDOOR UNIT CRANKCASE HEATERS BEEN ENERGIZED FOR 24 HOURS?
(Y/N)
INDOOR UNIT
HAS WATER BEEN PLACED IN DRAIN PAN TO CONFIRM PROPER DRAINAGE?
ARE PROPER AIR FILTERS IN PLACE?
(Y/N)
(Y/N)
HAVE FAN AND MOTOR PULLEYS BEEN CHECKED FOR PROPER ALIGNMENT?
DO THE FAN BELTS HAVE PROPER TENSION?
(Y/N)
(Y/N)
PIPING
40RM,RMQ
ARE LIQUID LINE SOLENOID VALVES LOCATED AT THE INDOOR UNIT COILS AS REQUIRED?
(Y/N)
HAVE LEAK CHECKS BEEN MADE AT COMPRESSORS, CONDENSERS, INDOOR COILS,
TXVs (Thermostatic Expansion Valves) SOLENOID VALVES, FILTER DRIERS, AND FUSIBLE PLUGS
WITH A LEAK DETECTOR?
(Y/N)
LOCATE, REPAIR, AND REPORT ANY LEAKS.
HAVE ALL COMPRESSOR SERVICE VALVES BEEN FULLY OPENED (BACKSEATED)?
ARE THE COMPRESSOR OIL SIGHT GLASSES SHOWING CORRECT LEVELS?
(Y/N)
(Y/N)
40RMS
HAS AIR BEEN BLED FROM SYSTEM?
(Y/N)
HAVE LEAK CHECKS BEEN MADE AT COMPRESSORS, CHILLERS, VALVES, AND INDOOR COILS?
(Y/N)
LOCATE, REPAIR, AND REPORT ANY LEAKS.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 111
Catalog No. 534-053
Printed in U.S.A.
Form 40RM-9SI
CL-1
11-95
Replaces: 40RM-1SI
Tab 3c 2e
CHECK VOLTAGE IMBALANCE
LINE-TO-LINE VOLTS:
AB
V
AC
(AB + AC + BC)/3 = AVERAGE VOLTAGE =
V
BC
V
V
V
MAXIMUM DEVIATION FROM AVERAGE VOLTAGE =
VOLTAGE IMBALANCE = 100 X (MAX DEVIATION)/(AVERAGE VOLTAGE) =
%
IF OVER 2% VOLTAGE IMBALANCE, DO NOT ATTEMPT TO START SYSTEM!
CALL LOCAL POWER COMPANY FOR ASSISTANCE.
C. Start-Up
CHECK EVAPORATOR FAN SPEED AND RECORD.
AFTER AT LEAST 10 MINUTES RUNNING TIME, RECORD THE FOLLOWING MEASUREMENTS:
COMP A1
COMP B1
OIL PRESSURE
SUCTION PRESSURE
SUCTION LINE TEMP
DISCHARGE PRESSURE
DISCHARGE LINE TEMP
ENTERING OUTDOOR UNIT AIR TEMP
LEAVING OUTDOOR UNIT AIR TEMP
INDOOR UNIT ENTERING AIR DB TEMP
INDOOR UNIT ENTERING AIR WB TEMP
INDOOR UNIT LEAVING AIR DB TEMP
INDOOR UNIT LEAVING AIR WB TEMP
OUTDOOR UNIT ENTERING WATER TEMP
(40RMS ONLY)
OUTDOOR UNIT LEAVING WATER TEMP
(40RMS ONLY)
INDOOR UNIT ENTERING WATER TEMP
(40RMS ONLY)
INDOOR UNIT LEAVING WATER TEMP
(40RMS ONLY)
COMPRESSOR AMPS (L1/L2/L3)
/
/
/
/
CHECK THE COMPRESSOR OIL LEVEL SIGHT GLASSES; ARE THE SIGHT GLASSES SHOWING
OIL LEVEL AT 1⁄8 TO 1⁄3 FULL?
(Y/N)
NOTES:
Copyright 1995 Carrier Corporation
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 111
Catalog No. 534-053
Printed in U.S.A.
Form 40RM-9SI
CL-2
596
11-95
Replaces: 40RM-1SI
Tab 3c 2e