Download Sharp AF-R120CX Service manual

Transcript
AF-R100CX
AF-R120CX
SERVICE MANUAL
S3203AFR12CX/
AIR CONDITIONER
MODELS
AF-R100CX
AF-R120CX
In the interest of user-safety the air conditioner should be restored to
its original condition and only parts identical to those specified should
be used.
TABLE OF CONTENTS
Page
SPECIFICATIONS ................................................................................................................................................. 2
WIRING DIAGRAM ................................................................................................................................................ 3
EXTERNAL DIMENSIONS .................................................................................................................................... 3
OPERATION INSTRUCTIONS ............................................................................................................................. 4
INSTALLATION INSTRUCTIONS ........................................................................................................................ 6
DISASSEMBLING PROCEDURE ......................................................................................................................... 8
HOW TO REPAIR REFRIGERATION ................................................................................................................ 12
ELECTRICAL COMPONENT TEST .................................................................................................................... 14
MICROCOMPUTER CONTROL SYSTEM .......................................................................................................... 15
TROUBLESHOOTING GUIDE ............................................................................................................................ 19
COOLING LOAD ESTIMATE FORM ................................................................................................................... 24
RUNNING CONDITION ....................................................................................................................................... 26
PACKING AND ACCESSORIES ......................................................................................................................... 27
REPLACEMENT PARTS LIST ............................................................................................................................ 28
SHARP CORPORATION
This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
1
AF-R100CX
AF-R120CX
SPECIFICATIONS
Models
Cooling capacity
Moisture removal
BTU/h
Pints/h
AF-R100CX
10000
2.7
AF-R120CX
12000
3.3
Hz
Volts
Amps
Watts
%
BTU/Wh
Single
60
115
9.0
1000
97
10.0
11.5
1200
91
10.0
COMPRESSOR
Type
Model, Remarks
(Hermetically sealed rotary type)
44R251AC-AJS, 840 W
44B124HX1EF, 1000W
REFRIGERANT SYSTEM
Evaporator
Condenser
Control O.D. x I.D. x Length x Q'ty(mm)
Refrigerant volume R-22(OZ)
Slit fin, Grooved tube, Ø 9.53 mm Hair pin
Louver fin, Grooved tube, 7mm Hair pin
Capillary tube 2.7 x 1.4 x 400 x 1
Capillary tube 2.7 x 1.2 x 800 x 2
18.3(Factory charged)
19.4(Factory charged)
NET DIMENSIONS
Width Height Depth
Net Weight
inches(mm)
lbs
22-1/16(560) x 14-3/4(375) x 24-5/16(617)
83
85
GROSS DIMENSIONS
Width Height Depth
Gross Weight
inches(mm)
lbs
25-25/32(655) x 18-29/32(480) x 27-7/8(708)
94
96
ELECTRICAL DATA
Phase
Rated frequency
Rated voltage
Rated current
Rated input
Power factor
EER
FAN SYSTEM
Indoor side(Evaporator)
Outdoor side(Condenser)
Air flow rate(indoor side) CFM
OTHERS
Safety devices
Air filter
Power cord length
Power plug type
ft
Centrifugal fan
Propeller fan
(High/Med/Low) 304 / 254 / 223
(High/Med/Low) 318 / 254 / 219
Compressor: Overload relay
Fan motor: Internal thermal protector
Polypropylene net
4.3
125V, 15A
ELECTRICAL PARTS
Running capacitor
Fan capacitor
250V-60µF
250V-6µF x 2
370V-50µF
250V-6µF x 2
Thermistor
Fan motor
Overload relay
15k at 78˚F
ARS030ZUEA/SHP(MLA895)
MRA4789-9053
ARS030ZUEA/SHP(MLA895)
MRA98693-12007
2
AF-R100CX
AF-R120CX
WIRING DIAGRAM
POWER SUPPLY CORD
115V 60Hz
NON RIBBED
GR
IN
MRY
OUT
FU1
CONTROL
BOAD UNIT
BK
OVERLOAD
PROTECTOR
BK
COMPRESSORC
MOTOR
RIBBED
RUNNING CAPACITOR
RUNNING
S
R
AF-R100CX AF-R120CX
CAPACITOR
WH
RE
250V 60µF 370V 50µF
FAN MOTOR
CAPACITOR
250V 6µF x 2
BK
BL
WIRE COLOR
BK : BLACK
BL : BLUE
RE : RED
WH : WHITE
GR : GREEN
GY : GRAY
OR : ORANGE
3A 125V
NR
C1
TR
YELLOW
CNR1
CNR2
GY
8
7
1
3
5
BK
BL
1 2 3 6 5 4 CONNECTOR BCN1
BL BK GY RE OR WH
H M L
FAN MOTOR
THERMAL
PROTECTOR
BK
M.C
A.C
BL
GY
RE
OR
WH
THERMISTOR
(ROOM TEMP)
CN1
CN2
BCN2
CNR3
RY1
RY2
RY3
DISPLAY
BOARD
UNIT
CN3
BCN3
Figure W-1
EXTERNAL DIMENSIONS
24-5/16"
5-3/16"
19/32"
14-3/4"
16-23/32"
27-5/32"
1-3/8"
22-1/16"
38-19/32"
3
TH1
AF-R100CX
AF-R120CX
OPERATION INSTRUCTIONS
UNIT
1
2
3
4
5
6
7
8
9
10
11
12
Front panel
Air inlet (Indoor side)
Louvers
Air outlet (Indoor side)
Exhaust lever
Control panel
5
6
4
7
8
3
9
10
Cabinet
2
Air outlet (Outdoor side)
1
Air inlet (Outdoor side)
Filter (Pull the filter handle to the right to remove.)
Filter handle
Power cord
12
11
CONTROL PANEL
SELECTOR indicator
2 Receiver window for remote control
signal
3 Display
4 SELECTOR pad
5 TIMER ON/OFF pad
6 TIMER indicator
1
1
7
8
9
10
11
2
3
HIGH COOL
MED COOL
F
LOW COOL
hr
FAN ONLY
TEMP
SELECTOR
TEMPERATURE setting pad
----Lower temp.
----Raise temp.
ENERGY SAVER pad
ENERGY SAVER indicator
POWER ON/OFF pad
POWER indicator
4
TIMER
5
POWER
ENERGY
SAVER
ON/OFF
6
7
8
ON/OFF
9
10 11
HOW TO OPERATE
COOLING OPERATION
Procedure
Pad
Display / Indicator
F
1. Touch POWER ON/OFF pad.
POWER
• The unit is preset at 74°F and HIGH
COOL. This will show in the display
when the power is first turned on.
ON/OFF
2. To turn off the unit, touch POWER ON/
OFF pad again.
POWER
hr
• POWER indicator and SELECTOR
indicator (HIGH COOL) will light.
ON/OFF
4
• POWER indicator and SELECTOR
indicator will go off.
AF-R100CX
AF-R120CX
TO CHANGE TEMPERATURE SETTING
Procedure
During cooling operation
Pad
Display / Indicator
TEMP
F
Touch the TEMPERATURE setting pad to
adjust the temperature setting.
• It can be set within the range of
64°F to 86°F.
hr
---Lower temp.
---Raise temp.
• Display will change as you touch the
pad.
The latest temperature setting will be memorized and will appear on the display the next time the unit is
turned on.
NOTE:
In cases of power outages or when the unit is disconnected; when the power is restored or the unit is
plugged in, the unit and display will return to the preset conditions of 74°F and HIGH COOL. The unit will
not automatically turn back on. The user must touch POWER ON/OFF to resume operation.
TO CHANGE FAN SPEED
Procedure
Pad
• SELECTOR indicator will
light in order as you touch.
During operation
Touch SELECTOR pad and select
the desired fan speed.
Display / Indicator
SELECTOR
HIGH COOL
MED
MED COOL
COOL
LOW COOL
FAN
ONLY
NOTES ON FAN SPEED
HIGH COOL
Fan and cooling at maximum performance.
Unit is preset to HIGH COOL when first turned on after unit is plugged in.
MED COOL
Fan operates at medium speed; cooling power at medium.
LOW COOL
Cooling for sleeping comfort with low fan speed.
FAN ONLY OPERATION
This setting can be used to circulate air whenever cooling is not desired.
The fan will operate at medium speed.
Procedure
Pad
During operation
Touch SELECTOR pad and select FAN
ONLY.
SELECTOR
Display / Indicator
• SELECTOR indicator FAN ONLY will
light, and the temperature display will
go off. After 5 seconds, the compressor
will stop and the unit will operate in
FAN ONLY mode.
When the unit is turned off, the last fan speed will be stored in memory.
The next time the air conditioner is used, the memorized fan speed will start automatically.
5
AF-R100CX
AF-R120CX
ENERGY SAVER
During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the
ENERGY SAVER is selected, the thermostat automatically controls cooling and the fan automatically stops when
the compressor is not operating. (Fan will stop 30 seconds after the compressor stops.)
Procedure
Pad
Display / Indicator
During cooling operation
1. Touch ENERGY SAVER pad.
2. To cancel, touch ENERGY SAVER pad
again.
ENERGY
SAVER
• ENERGY SAVER indicator will light.
ENERGY
SAVER
• ENERGY SAVER indicator will go off.
NOTE: ENERGY SAVER cannot be set during FAN ONLY mode operation.
TO CHANGE AIR FLOW DIRECTION
Adjust the louvers to change the direction of air flow for uniform and efficient cooling of the room.
Vertical louvers
Adjusts LEFT/RIGHT air flow
EXHAUST
If air in your room is stale, set the EXHAUST lever
to the OPEN position. This will exhaust stale air to
the outside. The EXHAUST lever should normally
be kept in the CLOSED position during cooling for
maximum efficiency.
Horizontal louvers
Adjusts UP/DOWN air flow
EXHAUST Lever
CLOSED
OPEN
INSTALLATION INSTRUCTIONS
ITEMS PACKED WITH THIS UNIT
No.
Accessories
1
Q'ty
1
Right closure assembly
1
2
Left closure assembly
1
3
Window sash foam seal
1
4
Window sash foam seal
(adhesive type)
1
5
Bottom gasket
1
6
Screws(L=1", 25.4mm)
8
6
8
2
7
6
3
7
Screws(L= 13/ 32", 10mm)
6
8
Remote control
1
9
Battery
2
10
Remote control hook
1
8
4
5
9
2
10
6
AF-R100CX
AF-R120CX
SUGGESTED TOOLS
CAUTION Do not remove any material (ex.
styrofoam, etc.) from inside the unit.
1. Screw driver (medium size Phillips)
2. Tape measure or ruler
3. Knife or scissors
INSTALLATION
These models can also be installed through the wall with
the optional through the wall mounting kit, model AZ80WK. To order this kit either contact your dealer or call
1-800-BE-SHARP.
The wall opening dimensions for through the wall installation
are:
25" (635mm) (W) x 17 -1/ 4 " (438mm) to 17-3/ 4"
(451mm) (H) x 4" (102mm) minimum (D).
Complete instructions are included with the wall mounting
kit.
WARNING: Make sure the unit is turned off and
unplugged before working.
4. Insert the right closure assembly and the left closure
assembly into the top angle and the bottom channels.
Secure the right and left closure to the cabinet with 6
of the provided screws. (L= 13/ 32 ", 10 mm)
Closure assembly
1-1. Cut the window sash foam seal (adhesive type) to the
proper length and attach it to the underside of the
window sash.
1-2. Attach the bottom gasket to the outer side of the
window sill.
window sash foam seal
(adhesive type)
5. Open the window sash and place the cabinet on the
sill. Close the window sash securely behind the top
angle.If there is space between the bottom channel
and the sill, fill the gap with a thin board or other hard
filler.
bottom gasket
2-1. Unscrew the 2 screws at the corners of the front panel.
Keep them as they will be used later.
2-2. Remove the front panel by pulling the front panel at the
lower corners towards you about an inch.
Next lift it up and pull it towards you.
CAUTION: Take care not to damage the exhaust
lever when removing the front panel.
WARNING:
At this step, make sure the cabinet is inclined
approximately 1 cm (3/8”) to the back. If the cabinet is
not properly inclined, the water collected in the bottom
tray during operation will not drain properly and may
flow into the room where the air conditioner is installed.
Horizontal
Louver
Cabinet
Front panel
Front
panel
Exhaust Lever
3-1. Unscrew the 6 stopper screws of the cabinet. Keep
the 4 screws from the top and front , as they will be
used later.
3-2. Slide the chassis out from the cabinet by pulling on the
hand hold located at the bottom center of the chassis.
sill
7
incline backwards about 1cm (3/8")
AF-R100CX
AF-R120CX
6. Insert the closure assemblies on both sides into the
rails of the jamb.
Jamb
(Left)
Closure assembly
(Left)
Closure assembly
(Left)
Sill
1/2 inch
(13mm)
9-1 Replace the front panel. Slip the exhaust lever through
the opening between the horizontal louver and the
front panel then, hook the cabinet top.
CAUTION:Take care not to damage the exhaust lever with
the front panel.
9-2. Screw the front cabinet on at the bottom corners with
2 screws removed in step 2.
Stool
7-1. Secure the cabinet to the window stool with 3 screws
(L=1", 25.4 mm), working from the inside of the cabinet.
7-2. Secure the top angle and the closure assemblies to
the window sash with 3 screws (L=1", 25.4 mm).
7-3. Secure the closure assemblies to the sill with 2 screws
(L=1", 25.4 mm).
Top angle
Horizontal
Louver
Front
Panel
Exhaust Lever
10.Cut the window sash foam seal to the proper length
and seal the opening between the top of the inside
window sash and the outside window sash.
Window sash foam seal
8-1. Slide the chassis back into the cabinet.
8-2. Replace the 4 screws removed in step 3 to the top
and side of the cabinet .
DISASSEMBLING PROCEDURE
CAUTION: DISCONNECT THE ROOM AIR CONDITIONER FROM THE POWER SUPPLY BEFORE ANY SERVICE
1. Unscrew the two screws holding the front panel on each
side.
2. Remove the front panel by pulling it at the lower corner
toward you about 1 inch and next lift up and pull it
toward you.
8
AF-R100CX
AF-R120CX
8. Unscrew the one screw holding earth wire .
3. Unscrew the four screws holding the cabinet.
Two screws are on top side.
Two screws are on each side.
9. Cut the fixing band holding the wires.
4. Slide the chassis away from the cabinet by pulling on
each corner of the base pan.
10.Remove the control unit.
5. Unscrew the four screws holding the control unit.
Two screws are on front side.
Two screws are on right side.
11.Unscrew the four screws holding control box cover.
Two are on the right side, one is on the left side, one is
on the back side.
CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR
AND RUNNING CAPACITOR BEFORE
TOUCHING THOSE CAPACITORS OR
OTHER COMPONENTS OR WIRING.
6. Unscrew the one screw holding the power supply cord.
12.Detach each terminals of fan motors by using long-nose
pliers.
7. Unscrew the one screw holding the wire holder.
Pull out thermistor holder.
9
AF-R100CX
AF-R120CX
13.Remove the putty and unfasten the one nut at the top of
compressor holding the terminal cover.
Then remove the wiring connector of the compressor
cord.
18.Unfasten the one nut holding propeller fan by rotating it
clockwise. And remove the propeller fan.
14.Unscrew the five screws holding the connecting stay.
19.Unscrew the three screws holding condenser shroud.
Note: Seal three female screws with siliconsealer
before re-installing.
15.Unscrew the two screws holding the shroud cover.
16.Unscrew the six screws holding the condenser and
condenser shroud.
Two screws are on the back side.
Four screws are on the each side.
Unscrew the two screws holding the condenser cover .
20.Unscrew the four screws holding the evaporator.
Two are on left side.
Two are on right side.
21.Remove the evaporator.
17.Remove the condenser by liftting up about 1 inch and
pull it toward you and move to right.
10
AF-R100CX
AF-R120CX
22.Unscrew the four screws holding the bulkhead.
Three screws are on the each side.
One screw is on the bottom side.
Note: Seal one female screws with siliconsealer
before re-installing.
27.Unscrew the three screws holding the printed wiring
board.
23.Unscrew the two screws holding the orifice
28.Detach terminals by using long-nose pliers.
24.Unfasten the one screw holding the centrifugal fan by
rotating it counterclockwise.
29.Unscrew the five screws.
Two screws are holding the fan motor capacitors.
One screw is holding the capacitor clamp.
Two screws are holding the transformer.
Unfasten the three spacers of the control box unit.
25.Unscrew the one screw holding the fan motor lead wire.
26.Remove the fan motor by unscrewing the four screws
that have large head holding it with bulkhead.
Note: Torque is 7 - 10 kgf.cm at re-installing.
11
AF-R100CX
AF-R120CX
HOW TO REPAIR REFRIGERATION
Before sealed system work can be preformed a refrigerant recovery EPA and LOCALLY approved certification is
required, additionally, EPA and LOCALLY approved refrigerant recovery equipment is required.
SEALED SYSTEM REPAIR
Sealed system repairs should be properly diagnosed before entering into a repair of the system.
It is important to follow proper procedures when doing a system repair for safety reasons and that the repair will result in a
restoration of the system to proper factory standards.
SAFETY REMINDERS
1) Do not heat any system component with an open flame for any reason.
2) Do not solder until you are sure that all refrigerant has been removed from the system.
3) Do not heat the charging cylinder with an open flame. Use warm water only and do not exceed 125˚F (not too hot to
keep your hand in.)
4) Do not over fill any charging cylinders, as they could explode when over
filled.
5) Use proper wrenches.
POOR FIT
GOOD FIT
6) Use safety goggles when working with refrigerants.
7) Keep a fire extinguisher within easy reach.
8) Watch flame direction when soldering so as not to burn clothing, wiring or
other components.
PROPER
9) Solder in a well ventilated area. If a high concentration of freon is present,
JOINT FIT
CLEARANCE
an open flame will create phosgene gas which can be harmful.
.001"TO .003"
PROPER SOLDERING
;;
;;
;; ;;
;;
;; ;;
;;
;; ;;
Joint Clearance.
Joint clearances should be maintained so that the brazing alloy will flow
between the closely mated surfaces rather than forming large fillets.
This films make the strongest joints, capillary attraction also work best with
close tolerance.
The best clearance is between 0.001" to 0.003", the amount of lap will be
approximately 3/8" depending on the swaging tool used. (Figure 1.)
CLEANING TUBING
To make a sound, leak tight joint, the brazing alloy when raised to brazing
temperature, must wet and flow freely over the entire surface of the tubing in
the joint area.
To assure this, the tubing surfaces must be free of all dirt, grease, oil and
oxides otherwise the alloy will not wet and flow properly over any surface with
these elements present. Cleaning can be done with an abrasive cloth or steel
wool. Never blow into the tubing because this will introduce a lot of moisture
into the system. Open tubing joints should be covered if exposed for long
periods of time.
Figure 1
EMERY CLOTH
;;;
;;;
;;;
;;;
KEEP TUBE IN
DOWNWARD POSITION
Cleaning Tubing.
Figure 2
PROPER FLUXING
Flux is necessary when using silver solder; it is not required when using silfos
on copper to copper joints.
To do a good job the flux should cover the tube surface completely. Be careful
not to introduce any flux inside the tubing.
Fluxing should be done after the tubing is mated together and just before
brazing is done. Do not allow it to dry out.
When brazing, the flux should become entirely liquid and clear, like water. The
temperature will be at 1100˚F and only a little more heat will allow the alloy
to flow freely into the joint.
3/8"
SILVER ALLOY
INNER CONE
TORCH STEM
Directing Torch Flame to Copper Tubing.
Figure 3
12
AF-R100CX
AF-R120CX
HEATING THE TUBING
Direct the torch flame so that the larger tube receives most of the heat. Silver
solder flows at 1200˚F and silfos flows at 1300˚F.
Heat all around the tubing.
The flame is composed of two cones, a smaller inner cone (pale blue) in color and
a much larger outer cone. The hottest part of the flame is at the tip of the inner
cone. The flame should be directed at the joint with the tip of the cone just touching
the surface of the tubing. Figure 3 and 4.
OUTER CONE
HOTTEST PART
OF FLAME
INNER CONE
TORCH STEM
Composition of Torch Flame.
Figure 4
DEHYDRATING SEALED SYSTEM
Many servicers feel that since air conditioners run with evaporator temperatures above 33˚F, moisture will not present a
problem. Nothing is further from the truth. Oxygen in moisture plus the heat produced during compression will react with the
refrigerant oil to produce harmful acids in the system which will break down motor winding insulation, create sludge and pit
component parts, reducing efficiency of the air conditioner and shortening the life of compressors.
There it becomes mandatory that good dehydrating practices be adhered to at all times.
Proper hook up procedures as shown in Figure 5 must be used in order to pull and good vacuum from the system.
The use of a good vacuum pump is very important so that the boiling point of any water in the system will be lowered to a
point where it will vaporize and be expelled from the system in the form of vapor.
Type of evacuation methods
1. Piston Type Compressor No good.
System parts must be above 110 ˚F.
LOW SIDE
GAUGE
2. Rotary Vacuum Pump Disavantages.
Low CFMC. 4 oil gets dirty.
3. Single State Vacuum Pump will not clean oil.
Oil must be changed often.
DIAL-CHARGE
CHARGING CYLINDER
ELECTRIC
VACUUM
GAUGE
TO RELATED SERVICE
VALVE OR PROCESS
TUBES OF THE UNIT.
HIGH SIDE
GAUGE
HIGH VACUUM
MANIFOLD
LARGE DIAMETER
BRAIDED VACUUM
HOSES
4. Two Stage Vacuum Pump will reach 50 microns.
First stage is below atmospheric pressure.
Moisture is removed into second stage which works up
to atmospheric pressure thus keeping oil clean.
Manometer cannot be read to 1/2 mm. Micron gauge
reads from 25,400 microns to 0.
Hook up for Evacuation and charging
HIGH VACUUM PUMP
Figure 5
It becomes clear that good equipment and maintained properly must be used in order to remove air and moisture from the
system.
When a vacuum of 1,000 to 500 microns is reached, block off the vacuum pump from the system.
This is done by closing the value between the pump and system. If the micron gauge does not increase above 1,000, the
system is free of moisture and no leak exists. If the micron gauge increases to higher levels moisture or a leak exists.
LEAKS
Several methods are used to detect leaks in systems.
Electronic Leak Detectors are very sensitive and are able to detect leaks down to 1/2 ounce per year.
A good electronic leak detector is generally far better in locating very small leaks.
Halide Torch be sure the room is free from refrigerant vapors. Watch the flame for the slightest change in color.
13
AF-R100CX
AF-R120CX
A very faint green indicates a small leak. The flame will be unmistakably changed to green or purple when large leaks
are encountered. To simplify leak detection pressurize the system to approximately 75 lbs.
Some leaks can be located by a visual inspection of the system components and solder joints and if oil is found at any
given location it generally is a sign that a leak exists at that point due to the fact that flame does carry oil with it travels
through the system.
Soap Bubbles
Liquid detergents can sometimes assist in finding small leaks by brushing detergent on the suspect area and
watching for bubbles. Before applying detergent be sure that the system is pressurized.
Tap line devices are permissible for diagnosis only they are not suitable when evacuating the system. After the diagnosis
has been made they must be removed so that the system will be restored to a hermeticly sealed condition.
ELECTRICAL COMPONENT TEST
RUNNING CAPACITOR AND FAN CAPACITOR
CAUTION: DISCHARGE THE RUNNING CAPACITOR AND FAN CAPACITOR BEFORE TOUCHING CAPACITOR
OR WIRING.
(1) Discharge capacitor by shorting terminals.
(2) Take the wires off the capacitor terminals.
(3) Set the selector switch of a volt-ohm-meter(or a tester) on the resistance range.
(4) Connect the probes to the capacitor terminals and watch the indicator swing.
The indicator does not swing at all ..... Open.
The indicator swings but does not return ..... Shorted.
The indicator swings, then returns a moment later ..... Good.
FAN CAPACITOR
RUNNING CAPACITOR
INSULATION TEST
Check the resistance between the terminals and case.
Reading must be more than 10M at DC 500V.
OVERLOAD RELAY
Check continuity between terminals with volt-ohm-meter.
INSULATION TEST
Check resistance between terminals and the relay case.
Reading must be more than 10M at DC 500V.
COMPRESSOR
(1) Take the wires off compressor terminals.
(2) Set selector switch of volt-ohm-meter on the resistance range.
(3) Put the probes on the terminals of the compressor and check continuity between each terminal.
INSULATION TEST
Check the resistance between the terminals and the copper tube.
Reading must be more than 10M at DC 500V.
14
AF-R100CX
AF-R120CX
MICROCOMPUTER CONTROL SYSTEM
1. Temperature control characteristic
1-1 COOL operation
In the “COOL” mode, the thermostat circuit is controlled
by two thermostat lines (C1, C2).
3. Fan speed
Fan speeds are given by the fan motor, “H”, “M” and
“L”, which are available in the following operation
mode.
Room temperature (°F)
Table Y-1
86
C1
84
C2
Fan motor
H
M
L
M
4. 12-hours timer
64
62
64
Preset temperature (°F)
("THERMO" switch)
86
Figure Y-1
2. Operation mode
2-1 COOL operation
The compressor turns on or off, at thermostat lines C1
and C2. The fan motor is also controlled with the
compressor.
States 1 & 3 : Compressor ON
States 2
: Compressor OFF
3
Room temperature (°C)
Selector
HIGH COOL
MED COOL
LOW COOL
FAN ONLY
C1
4-1 OFF-TIMER operation
Set the delay timer during operation.
The unit will turn off automatically according to your
setting. Timer duration can be set by 0.5 hours to
maximum 12 hours. Up to 9.5 hours, you can set by 0.5
hours increments and from 10 to 12 hours, by 1 hour
increment.
If you touch button “POWER ON/OFF” during OFFTIMER operation, then the unit turns off and OFFTIMER operation is cancelled.
4-2 ON-TIMER operation
Set the delay timer when unit is not operating.
The unit will turn on automatically according to your
setting. Timer duration can be set by 0.5 hours to
maximum 12 hours. Up to 9.5 hours, you can set by
0.5 hours increments and from 10 to 12 hours, by 1
hour increment.
If you touch button “POWER ON/OFF” during ONTIMER operation, then the unit turns on and ON-TIMER
operation is cancelled.
ON-TIME and OFF-TIME display will count down the
remaining time.
from 0.5 to 9.5 ..... 0.5 hours
from 10 to 12 ....... 1 hour
1
C2
2
Room temperature transition
5. Energy saver
During normal operation, the thermostat automatically
controls cooling and the fan runs continuously whenever
the air conditioner is in operation.
When the ENERGY SAVER is set, the thermostat
automatically controls cooling and the fan automatically
stop when compressor is not operating. (Fan will stop
in 30 seconds after the compressor stops.)
ON
Compressor
OFF
Preset temperature (°C)
Figure Y-2
ON
Fan
2-2 FAN ONLY operation
The fan motor always turns on.
OFF
30 seconds
Figure Y-3
15
AF-R100CX
AF-R120CX
6. Safety start
When you turn the air conditioner OFF and restart again soon, wait at least 3 minutes before the cooling operation
starts.
7. Test mode
Keep pushing both buttons “POWER ON/OFF” and “ " ” and supply the power, the system will go to the test mode.
In this mode, the output operation is switched by pushing buttons. Normal outputs are shown in Table Y-2.
Table Y-2
No.
Push key
(Switch)
Input-check
LED lighting
Output-check
TH1
HIGH MED LOW FAN POWER TIMER ENERGY FAN COMP
LED1 Open/Short check COOL COOL COOL ONLY ON/OFF
SAVER output output
Indicator by LED2 [LED2] [LED3] [LED4] [LED5] [LED6] [LED7] [LED8]
0
Plug in the power supply
cord while pushing
POWER ON/OFF key
and
(down) key.
8.8
1
2
3
4
5
6
7
8
9
SLECTOR (SW3)
SLECTOR (SW3)
SLECTOR (SW3)
POWER "ON/OFF" (SW4)
UP (SW5)
DOWN (SW6)
TIMER (SW2)
ENERGY SAVER (SW1)
POWER ON/OFF
by the Remote control
0.1
0.1
0.1
0.2
0.3
0.4
0.5
0.6
0.6
TH: OK
TH: OK
TH: OK
TH: OK
TH: OK
TH: OK
TH: OK
TH1: OPEN/SHORTcheck(
= Thermistor check included,
=OK)
Check item
and Remark
OFF
OFF
All LEDs lighting
LOW
MED
HIGH
OFF
LOW
MED
HIGH
OFF
LOW
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FAN output check
Key operation check
Remote control operation
check (Receive)
Comp.: Not output
= Thermistor check not included
Table Y-3
T(˚C)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
T(˚F)
32.0
33.8
35.6
37.4
39.2
41.0
42.8
44.6
46.4
48.2
50.0
51.8
53.6
55.4
57.2
59.0
60.8
62.8
64.4
66.2
68.0
R(k )
49.33
46.86
44.53
42.33
40.25
38.29
36.44
34.68
33.02
31.45
29.96
28.55
27.22
25.96
24.76
23.62
22.56
21.52
20.55
19.63
18.76
T(˚C)
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
V(volts)
1.17
1.21
1.26
1.31
1.36
1.41
1.46
1.51
1.56
1.61
1.67
1.72
1.78
1.83
1.89
1.94
2.00
2.05
2.11
2.17
2.22
V ....... Input the voltage of microcomputer (No. 10-port).
16
T(˚F)
69.8
71.6
73.4
75.2
77.0
78.8
80.6
82.4
84.2
86.0
87.8
89.6
91.4
93.2
95.0
96.8
98.6
100.4
102.2
104.0
R(k )
17.93
17.14
16.39
15.68
15.00
14.36
13.74
13.16
12.60
12.07
11.57
11.09
10.63
10.19
9.78
9.38
9.00
8.64
8.30
7.97
V(volts)
2.28
2.33
2.39
2.44
2.50
2.55
2.61
2.66
2.71
2.77
2.82
2.87
2.93
2.98
3.03
3.08
3.13
3.17
3.22
3.27
BK
BL
BK
BK
M
CONNECTOR
WHITE
ORANGE
RED
GRAY
R
BL
FAN
MOTOR
A
H M L
5
3
1
6
7
C
S
RY1
CNR1
RY2
CNR2
RY3
CNR3
YELLOW
C13 16V 10µF
R22 10k(F)
NO INSERT PART
25˚C
TH1(15k)
ROOM
Temp
CNR1 - CNR3
BCN1
RUNNING
CAPACITOR
COMPRESSOR
MOTOR
OVERLOARD
PROTECTOR
3A
125V
CN1
IF NOT SPECIFIED 1SS133T-72 (DIODE)
: INDICATED POSITION IS FUNCTION TEST POINT
RY3
RY2
RY1
MRY
C13
+
R9
10K
D8
C14
16V
10µ
+
D7 D6
D5
R1
22K
D3
SW1: ENERGY SAVER
SW2: TIMER
SW3: SELECTOR
SW4: POWER
SW5: UP-KEY
SW6: DOWN-KEY
12V
IF NOT SPECIFIED 50V 1000pF (CAPACITOR)
IF NOT SPECIFIED 1/5W, ±5% (RESISTOR)
4
3
2
1
FAN L
FAN M
FAN H
COMP
NR
271
250V
0.1µF
C1
D1
R22
Q2
-5V
C3
25V
0.1µ
C4
Q1
5V
IN
25V
47µ
C5
+
10V
C6
CA1: 1000pF x 8
RA1: 10kΩ x 8
5V
C12
25V
0.1µ
5V
RA1
TEST
C22
C21
5V
10µ
C20
5V
25V
0.1µ
C7
+ C11
16V
COM
100µ
OUT
IC3
79L05
Vdd 28
HOLD 27
R92 26
R91 25
R90 24
R83 23
INT1 22
R81 21
INT2 20
R63 19
R62 18
R61 17
R60 16
R53 15
5V
12V
+
IC1
1 X OUT
2 X IN
3 RESET
4 R70
5 R71
6 R72
7 R40
8 R41
9 R42
10 R43
11 R50
12 R51
13 R52
14 V SS
4MHz
OSC
Q7: KRA106M
(DTA143ZS)
Q7
Q1: KRA105M
(DTA123JS)
5V
C10
R3
10K
OUT
COM
IC2
7812
25V
25V
1000µ 0.1µ
C2
IN
Electronic Control Circuit Diagram
R10
15K(F)
Q2, Q3, Q4
KRA106M
(DTA143ZS)
Q3
C9
16V
0.01µ
Q4
BZ
R8
2.7K
R4
20k
+
Q6
KRC101M
(DTC143ES)
D4
D2
D1 - D4
ZD1
R2
HZ4A-2 15K
CA1
+
7
6
5
4
3
2
1
CN3
Q8
0V
BCN3
BCN2
1
2
3
4
5
6
7
8
5V
CN2
25V
0.1µ
C8
KRA101M
(DTA143ES)
Q5
10K
R7
MRY
CA1: 1000pF x 8 (CAPACITOR ARRAY)
RA1: 10kΩ x 8 (RESISTOR ARRAY)
BL
1 2 3 6 5 4
BK
GRAY
WH
OR
BL
GY
FAN MOTOR
CAPACITOR
250V 6µF x 2
GR
RE
R21
10K
R20
10K
TR
C17
+
Q8 ~ Q10
KRA222M
(DTB123EA)
Q10
Q9
LED1
9
10
PHOTO
DETECTOR
UNIT
IC4
88
C18
16V
10µ
1
18
R12
FU1
TMP47C443N
10K
R6
10K
R5
C15
RUNNING CAPACITOR
AF-R100CX AF-R120CX
250V 60µF 370V 50µF
RE
GY
WH
17
C16
E/SAVER
SW1
D10
TIMER
SW2
D11
SELECTOR
SW3
D12
POWER
SW4
D13
UP-KEY
SW5
D14
POWER SUPPLY
115V AC
60Hz
QWN-KEY
SW6
D15
16V 10µF
C19
LED7, LED8
LED6
LED10
R15
D17
R11
COLOR
GREEN
YELLOW
RED
ORANGE
R13
R14
LED2, LED3, LED4, LED5
R16
HEATSINK
R11 ~ R18
150Ω x 8
LED8 ENERGY
SAVER
LED7 TIMER
LED6 ON/OFF
LED5 FAN
LED4 COOL/L
LED3 COOL/M
LED2 COOL/H
AF-R100CX
AF-R120CX
R17
R18
AF-R100CX
AF-R120CX
DPWBFA193JBKZ
7
D8
RY1
JP4 D7 GND D6
RY3
CNR3
8
R
94V0
R15
JP23
D13
(GRAY)
CNR2
CNR1
1
BCN3 (FAN MOTOR) (RED)
Printed Wiring Board
18
OUT
MRY
C1
C19
C7
JP3
C16
R7
AE2A V0
AE2B V0
VB
C6
R6
IN
C11
FU1
JP2
8888 8
C20
C22
1
RY2
1
CN3
12V POWER CORD
C21
NR
R5
C12
125V 3A
OUT
IC3
8
E
5V
7
COM
D1
C5
JP1
D3
D2
D17
C4
R21
R20
C15
CN2
RA1
OUT
E
E
D5
R3
IC1
E
B
B
Q4
JP9 Q1
28 JP5
B
C
B
JP8
15
JP10 R8
Q3
TEST
COMP
JP7
OSC
JP6
R10
C10
14
CA1
IC2
IN
B
C
E
JP11
JP36
C2
BZ
Q7
Q5
B
C
E
DPWBFAA193JBKZ
C14
C3
R12
VB
JP12
CB
R2
JP14
Q6
ZD1
R9
C9
R1
R4
QPWBFB376JBZZ
B
C
POWER
E/SAVER
AE2A V0
AE2B V0
94V0 R
CN1 4
SW4
D10
JP18
UP-KEY
DWN-KEY
8888 8
1
ON/OFF
SW1
D14
D15
TIMER
Q2
SELECTOR
D11
JP17
JP16
D12
JP15
SW2
ENERGY
SAVER
SW5
SW6
RED
LED8
JP20
TIMER
SW3
D4
JP29
JP28
R16
R17
R14
JP27
JP26
JP25
R13
JP24
YELLOW
LED8
JP19
C18
IC4
9
YELLOW
LED7
FAN
Q9
JP31
B C E
1
C17
E
B C E
Q8
LED1
LED5
GREEN
Q10
JP39
JP37
JP38
JP35
COOL/ L
B C E
JP40
JP36
JP34
1
BCN3
JP30
JP32
LED3
GREEN
COOL/ M GREEN
LED4
8
1
BCN2
10
R11
18
JP22
COOL/ H
R18
JP33
JP21
QPWBFB376JBZZ
LED2
GREEN
AF-R100CX
AF-R120CX
TROUBLESHOOTING GUIDE
No cooling
(Operation not at all.)
Measure the power supply
voltage at receptacle.
under 100V
120V(over 100V)
The house fuse or circuit
breaker open ?
not open.
open
Is it proper current capacity of the
house fuse or the circuit breaker ?
proper
Ask the power supply
company for check.
not proper
Change the house fuse and
the circuit breaker turn on.
Is it sufficient current capacity
of power equipment ?
Is it small wiring for power
supply equipment ?
insufficient
Ask the power supply
company for check.
sufficient
Is plug disconnecting ?
disconnecting
Connect plug properly.
connecting
Check the power supply cord.
imperfect contact
OK
Change the power supply cord.
Check the fuse on PWB ass'y. open
Change the fuse on PWB ass'y.
OK
Measure the secondary
voltage of transformer.
under 14V(AC)
over 14V(AC)
Measure the voltage between NG
-12V and GND on PWB ass'y.
OK(12V, DC)
Measure the voltage between
-5V and GND on PWB ass'y.
NG
Change PWB ass'y.
OK(5V, DC)
If unit operate, dose the house
fuse or the circuit breaker open ?
NO
YES
Measure the insulation
resistance of compressor.
NG(under 10MΩ)
OK(over 10MΩ)
Change the compressor.
NG(under 10MΩ)
Measure the insulation
resistance of fan motor.
OK(over 10MΩ)
Change the fan motor.
Can the Compressor operate ? can't operate
can operate
Checking complete.
19
Change the compressor.
AF-R100CX
AF-R120CX
No cooling
(Fan operate but the
compressor doesn't operate.)
Measure the power
supply voltage at
receptacle.
under 100V
Ask the power supply
120V(over 100V) company for check.
insufficient
Is it sufficient current
capacity of power
equipment ?
Ask the power supply
Is it small wiring for power
company for check.
supply equipment ?
sufficient
Measure the current in
compressor circuit.
current
Check the
overload relay.
no current
imperfect contact
Change the
overload relay.
short
OK
Check the
running capacitor.
open
Check the
overload relay.
Change the
overload relay.
disconnecting
Is the connector
disconnecting ?
NG
connecting
Connect properly.
Change the running
capacitor.
OK
Check the compressor
relay.(MRY on PWB)
NG
OK
Change PWB ass'y.
Check the thermister.
NG
Change the thermistor.
OK
Measure the resistance
of compressor coil.
NG
Change the compressor.
OK
Is there high heat
source near the unit.
Checking method for the compressor relay.
(MRY on PWB)
Turn off the
power supply.
there is
Remove the high heat
source or stop.
there isn't
Measure the
resistance of its coil.
NG
OK(160Ω at 20ûC)
Is the outdoor
temperature too high ?
over 43ûC
under 43ûC
Check the outdoor heat
exchanger.
not dirty
Can the compressor
operate ?
can operate
Turn on the power
supplty as operating the
compressor.
Avoid sun light and
ventilate well for outdoor
heat exchanger.
Measure the
voltage to its coil.
dirty
NG
OK(12V, DC)
Clean them with steam
cleaner or another method.
OK
can't operate
Change the compressor.
Checking complete.
20
NG
AF-R100CX
AF-R120CX
No cooling
(The compressor operate but
the fan motor doesn't operate)
crack at the solder part
Check BNC1 on PWB
ass'y
Repair with over solder.
disconnecting the connector
Connect the connector
properly.
OK
Check the fan motor
capacitor.
NG
OK
Measure the resistance
of compressor coil.
Change the fan motor
capacitor
NG
OK
Is the fan locked ?
Change the fan motor.
locked
Is the fan touched to
another parts ?
touch
Change fan or another
parts, or adjust.
no touch
Change the fan motor.
Checking complete
The compressor doesn't
turn off.
Check the thermister
connector.
disconnecting
Connect the connector
properly.
OK
Check the thermister
resistance.
NG
Change the thermister.
OK
Checking method for the compressor relay.
(MRY and PWB)
Check the compressor
relay.
OK
NG
Turn off the power
supply.
Change PWB ass'y.
Checking complete.
Measure the contact
resistance.
short
open
OK
21
NG
AF-R100CX
AF-R120CX
Insufficient cooling(Both compressor and compressor operate)
Check the temperature setting.
OK
too high
Set the lower temperature.
dirty
Check the air filter.
not dirty
Clean the air filter.
Is there high heat source or
any object restricting heat
radiation near the unit.
there is
Remove the high heat
source or stop.
there isn't
Check doors and windows.
close
Check the outdoor and indoor
heat exchanger.
open
Doors and windows
must be kept closed.
dirty
not dirty
Clean them with steam
cleaner or another method.
Calculate heat load wit using
Cooling load estimate form.
OK
Check rotating direction of
centrifugal fan.(to clockwise)
OK
Check changing fan speed
properly.
Undersized air conditioner
NG
Change unit to proper
sized air conditioner.
NG
Check the fan motor connector.
OK
NG
OK
Measure the resistance NG
of fan motor coil.
OK
Is the outdoor temperature
too high ?
Change the fan motor.
over 40ûC
Avoid sun light and ventilate well for
outdoor heat exchanger.
under 40ûC
Check the thermister.
OK
Connect properly.
NG
Change the thermister.
under 10ûC
Measure temperature difference
between inlet and outlet air at indoor.
over 10ûC
Is frost sticking to capillary tube ?
Or is indoor heat exchanger no cold ?
YES
Is the refrigerant leaked ?
NO
The capillary tube restrict,
and change the capillary tube.
NO
Measure the emperature
difference between discharge
tube and suction tube.
YES
Repair leakage and recharge
the refrigerant.
No temperature difference
The compressor is defective.
temperature difference
Change the compressor.
Checking complete.
22
AF-R100CX
AF-R120CX
Excessive vibration
or Abnormal noise
At fan only mode,
Excessive vibration
or Abnormal noise
YES
Check the air filter
dirty
NO
not dirty
Check rotating
direction of centrifugal
fan.(to clockwise)
OK
Clean the air filter.
NG
Check the fan motor
connector.
OK
Measure the resistance
of fan motor coil.
OK
Is the fan deformed or
broken.
OK
Is loosened screw
and nut fixing fan ?
OK
deform or broken
Change the fan
loosened
Tighten up.
Checking complete
Is each screws
loosened ?
loosen
OK
Is pipe touching to
another parts.
Tighten up
touching
Repair with adjusting
shape of pipes.
OK
Check mounting of
compressor.
OK
Check compressor
noise and vibration.
OK
NG
Repair mounting or
change compressor
cushion.
too big
Change compressor.
Checking complete
23
NG
Connect properly.
NG
Change the fan motor.
AF-R100CX
AF-R120CX
COOLING LOAD ESTIMATE FORM
INSTRUCTIONS FOR USING COOLING LOAD ESTIMATE FORM FOR ROOM AIR CONDITIONERS
(AHAM PUB. NO. RAC-1)
A. This cooling load estimate form is suitable for estimating the cooling load for comfort air conditioning installations
which do not require specific conditions of inside temperature and humidity.
B. The form is based on an outside design temperature of 95˚F dry bulb and 75˚F wet bulb. It can be used for areas in
the continental United States having other outside design temperature by applying a correction factor for the
particular locality as determined from the map.
C. The form includes "day" factors for calculating cooling loads in rooms where daytime comfort (such as living rooms,
offices, etc.).
D. The numbers of the following paragraphs refer to the correspondingly numbered item on the form:
1. Multiply the square feet of window area for each exposure by the applicable factor. The window area is the area
of the wall opening in which the window is installed. For windows shaded by inside shades or venetian blinds, use
the factor for "Inside Shades". For windows shades by outside awnings or by both outside awnings and inside
shades (or venetian blinds), use the factor for "Outside Awnings". "Single Glass" includes all types of single
thickness windows, and "Double Glass" includes sealed air space types, storm windows, and glass block. Only
one number should be entered in the right-hand column for item 1, and this number should represent only the
exposure with the largest load.
2. Multiply the total square feet of all windows in the room by the applicable factor.
3a. Multiply the total length (linear feet) of all walls exposed to the outside by the applicable factor. Doors should be
considered as being part of the wall. Outside walls facing due north should be calculated separately from outside
walls facing other directions. Walls which are permanently shaded by adjacent structures should be considered
as being "North Exposure". Do not consider trees and shrubbery as providing permanent shading. An insulated
frame wall or a masonry wall 8 inches or less in thickness is considered "Light Construction". An insulated frame
wall or a masonry wall over 8 inches in thickness is considered "Heavy Construction".
3b. Multiply the total length (linear feet) of all inside walls between the space to be conditioned and any unconditioned
spaces by the given factor. Do not include inside walls which separate other air conditioned rooms.
4. Multiply the total square feet of roof or ceiling area by the factor given for the type of construction most nearly
describing the particular application. (Use one line only.)
5. Multiply the total square feet of floor area by the factor given. Disregard this item if the floor is directly on the
ground or over a basement.
6. Multiply the number of people who normally occupy the space to be air conditioned by the factory given. Use a
minimum of 2 people.
7. Determine the total number of watts for lights and electrical equipment, except the air conditioner itself, that will
be in use when the room air conditioning is operating. Multiply the total wattage by the factor given.
8. Multiply the total width (linear feet) of any doors or arches which are continually open to an unconditioned space
by the applicable factor.
NOTE: Where the width of the doors or arches is more than 5 feet, the actual load may exceed the calculated
value. In such cases, both adjoining rooms should be considered as a single large room, and the room air
conditioner unit or units should be selected according to a calculation made on this new basis.
9. Total the loads estimated for the foregoing 8 items.
10. Multiply the sub total obtained in item 9 by the proper correction factor, selected from the map, for the particular
locality. The result is the total estimated design cooling load in BTU per hour.
E. For best results a room air conditioner unit or units having a cooling capacity rating(determined in accordance with the
NEMA Standards Publication for Room Air Conditioners, CN 1-1960) as close as possible to the estimated load
should be selected. In general, a greatly oversized unit which would operate intermittently will be much less
satisfactory than one which is slightly undersized and which would operate more nearly continuously.
F. Intermittent loads such as kitchen and laundry equipment are not included in this form.
24
AF-R100CX
AF-R120CX
BTU/Hr
(Quantity
x Factor)
FACTORS
HEAT GAIN FROM
QUANTITY
DAY
No
Shades
1. WINDOWS: Heat gain from sun.
Northeast
Southeast
South
Southwest
Southeast
West
Northwest
North
Inside
Shades
Outside
Shades
20
25
20
20
30
45
35
0
(Area a
Factor)
Use
only
the
largest
load
Use
only
only
60
25
80
40
75
30
75
35
110
45
sq ft
150
65
sq ft
sq ft
120
50
sq ft
0
0
These factors are for single glass only. For glass block, multiply the above factors
by 0.5: for double-glass or storm windows, multiply the above factors by 0.8.
sq ft
sq ft
sq ft
2. WINDOWS: Heat gain by conduction.
(Total of all windows)
Single glass
Double glass or glass block
14
7
sq ft
sq ft
Light Construction
3. WALLS: (Based on linear feet of wall.)
a. Outside walls
Noth exposure
Other than North exposure
b. Inside Walls (between conditioned
and unconditioned spaces only)
ft
ft
4. ROOF OR CEILING: (Use one only.)
a. Roof, uninsulated
b. Roof, 1 inch or more insulation
c. Ceiling, occupied space above.
d. Ceiling, insulated with attic space
above
e. Ceiling, uninsulated, with attic space
above
5. FLOOR: (Disregard if floor is directly
on ground or over basement.)
Heavy Construction
20
30
30
60
ft
30
sq ft
sq ft
sq ft
19
8
3
sq ft
5
sq ft
12
sq ft
3
600
6. NUMBER OF PEOPLE:
7. LIGHTS AND ELECTRICAL
EQUIPMENT IN USE
3
watts
8. DOORS AND ARCHES
CONTINUOUSLY OPENED TO
UNCONDITIONED SPACE:
(Linear feet of width.)
300
ft
9. SUB-TOTAL
xxxxx
10. TOTAL COOLING LOAD:
(BTU per hour to be used for selection
of room air conditioner(s).)
xxxxx
(Item 9) x
(Factor from Map) =
FARGO
ROCHESTER
EUGENE
ALBANY
GREEN BAY
NEW HAVEN
RENO
SACRAMENT
FRESNO
LAS VEGAS
PUEBLO
WICHITA
COLUMBIA
BIRMINGHAM
PHOENIX
ATLANTA
SAN ANTONIO
25
AF-R100CX
AF-R120CX
RUNNING CONDITION
Note:
1. Select mode of the Running Condition of a Room Air Conditioner.
SELECTOR ................................................ HIGH COOL
TEMPERATURE .................................................... 64°F
2. Data of Performance Curve is measured between 40RH% and 70RH%.
If you measure the Room Air Conditioner above or below this rating, the data may miss the range of the performance
curve.
3. Outlet air temp. is influenced by the method of measurement. Measurement examples are shown.
4. Use power input data when checking the Running Condition.
RUNNING CONDITION FOR
MODEL AF-R120CX
RUNNING CONDITION FOR
MODEL AF-R100CX
PERFORMANCE CURVE
1500
1000
1400
900
1300
Power input (Wa tt)
1100
800
700
600
1200
1100
1000
900
800
9
13
Line current(Amp.)
10
8
7
6
35
(96)
30
(88)
25
(77)
20
(68)
15
(59)
10
(50)
25
(77)
30
35
(86)
(96)
Outside air temp. C( F)
40
(104)
Outlet air temp. C ( F)
Outlet air temp. C ( F)
Line current(Amp.)
Power input (Wa tt)
PERFORMANCE CURVE
12
11
10
9
30
(88)
25
(77)
20
(68)
15
(59)
10
(50)
5
(41)
25
(77)
26
30
35
(86)
(96)
Outside air temp. C( F)
40
(104)
AF-R100CX
AF-R120CX
PACKING AND ACCESSORIES
Closure ass'y
4
Top pad B
Top pad F
3
Packing case
2
Bag
Bottom pad ass'y
1
27
AF-R100CX
AF-R120CX
REPLACEMENT PARTS LIST
REF. NO.
PART NO.
DESCRIPTION
Q'TY
CODE
CABINET AND UNIT PARTS
1- 1
1- 2
1- 2
1- 3
1- 4
1- 5
1- 6
1- 7
1- 8
1- 9
1-10
1-11
1-12
1-13
1-14
1-15
1-16
1-17
1-18
1-19
1-20
1-21
1-22
1-23
1-24
1-24
1-25
1-25
1-26
1-27
1-28
1-29
1-30
1-31
1-32
1-33
1-34
1-35
1-36
1-37
1-38
1-39
1-40
1-41
1-42
1-43
1-44
1-45
1-46
1-47
1-48
1-49
1-50
1-51
1-52
1-53
1-54
1-55
1-56
1-57
1-58
1-59
1-60
1-61
1-62
1-63
CMOTLA895JBEZ
DCHS-A442JBTA
DCHS-A440JBTA
DCAB-A094JBTA
PSEL-B150JBE0
HPNLCA770JBFA
PSEL-C059JBEZ
LANG-A459JBWZ
LANG-A355JBTA
LHLD-A482JBFZ
CLEV-A035JBKZ
NFANPA092JBFZ
NFANSA030JBFZ
PFILMA116JBEB
PFPFPB466JBE0
PKESPA082JBTA
PKESPA083JBFA
LBND-A046JBE0
LCOV-A002JBF0
PCOV-A320JBP0
PSEL-C057JBEZ
LANG-A356JBTA
PSKR-A207JBFA
PSRA-A120JBFZ
TLAB-C206JBRZ
TLAB-C205JBRZ
TSPC-E052JBRZ
TSPC-E051JBRZ
GWAKPA136JBFB
GWAKPA135JBFB
TLABBA110JBRA
LANGAA038JBFB
LANGAA039JBFB
PPLTPA013JBFB
PSPRCA010JBE0
TLABKA564JBE0
PFPFPB446JBE0
CWAK-C095JBKZ
MJNTPA074JBFB
MLOV-A252JBFB
MLOV-A253JBFB
PSEL-B360JBE0
PSEL-C064JBEZ
PSEL-B361JBE0
PSEL-B367JBE0
PSEL-B516JBE0
PFPFPB443JBE0
PSEL-C063JBEZ
PSEL-B519JBE0
PSEL-C056JBEZ
LHLDW0367JBE0
LHLDW0368JBE0
PFPFPB528JBE0
PSEL-A432JBE0
PFPFPB611JBE0
PSEL-B532JBE0
PSEL-B394JBE0
PSEL-B560JBE0
LANG-A507JBWZ
HPNLCA771JBEA
PSEL-B366JBE0
PSEL-C104JBEZ
PSEL-C105JBEZ
LHLDW0363JBE0
PSHE-A191JBEZ
LHLD-A356JBE0
Fan motor
Base pan ass’y [AF-R100CX]
Base pan ass’y [AF-R120CX]
Cabinet ass’y
Cabinet seal
Control panel
Evaporator insulator
Conecting stay
Top inst. Angle
Thermistor holder
Damper ass’y
Propeller fan
Centrifugal fan
Air filter
Insulator
Condenser shroud
Orifice
Wire fixing band
Shroud cover
Motor cover
Tube insulator
Bottom inst. Angle
Bulkhead
Drain tray
Energy card [AF-R100CX]
Energy card [AF-R120CX]
Name badge [AF-R100CX]
Name badge [AF-R120CX]
Louver duct
Front panel
SHARP badge
Left closure frame
Right closure frame
Closure
Spring
Number card
Insulator
Front panel ass’y
Louver link
Vertical louver A
Vertical louver B
Cabinet insulator
Drain tray insulator
Cabinet insulator
Cabinet insulator
Base pan insulator
Insulator
Bulkhead insulator
Angle insulator
Motor seal
Wire holder
Wire holder
Panel insulator
Damper insulator
Insulator
Damper insulator
Panel insulator
Damper insulator
Fan motor angle
Decoration panel
Panel insulator
Insulator
Cabinet insulator
Wire holder
Sheet
Wire holder [AF-R120CX]
28
1
1
1
1
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
2
4
2
1
1
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
BN
BC
BC
BF
AD
AF
AD
AC
AP
AE
AE
AV
AU
AN
AC
AV
AQ
AE
AM
AC
AD
AE
BA
AE
AC
AC
AC
AC
AH
AT
AB
AK
AK
AL
AD
AC
AC
AX
AC
AB
AC
AB
AC
AE
AC
AC
AC
AC
AD
AE
AA
AA
AD
AC
AG
AB
AB
AB
AH
AM
AD
AB
AE
AA
AE
AE
AF-R100CX
AF-R120CX
REF. NO.
PART NO.
DESCRIPTION
Q'TY
CODE
CONTROL BOX PARTS
2- 1
2- 1
2- 2
2- 3
2- 4
2- 5
2- 6
2- 7
2- 7
2- 8
2- 9
2- 9
2-10
2-10
2-11
2-12
2-13
2-14
2-15
LBNDKA078JBWZ
LBNDKA096JBWZ
LPLTMA128JBW0
DPLT-A047JBW0
QACC-A263JBZZ
RH-HXA011JBZZ
QW-VZD104JBE0
QW-IZA037JBZZ
QW-IZA036JBZZ
RC-HZA256JBE0
RC-HZA435JBZZ
RC-HZA407JBZZ
TLABCB579JBRZ
TLABCB377JBRZ
DPWBFA193JBKZ
PSPA-A084JBE0
PSPA-A085JBE0
QFS-AA048JBE0
LBND-A042JBE0
Capacitor clamp [AF-R100CX]
Capacitor clamp [AF-R120CX]
Control box cover
Cont. box angle ass’y
Power supply cord
Thermistor
Lead wire
Lead wire [AF-R100CX]
Lead wire [AF-R120CX]
Fan motor capacitor
Running capacitor [AF-R100CX]
Running capacitor [AF-R120CX]
Wiring diagram [AF-R100CX]
Wiring diagram [AF-R120CX]
Control board unit
Spacer
Spacer
Fuse
Wire fixing band
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
4
AD
AC
AK
AS
AT
AL
AD
AS
AS
AM
AY
AY
AA
AC
BC
AC
AC
AB
AC
1
1
1
1
1
1
1
1
1
1
1
1
3
3
1
1
1
1
1
1
1
1
1
1
1
2
CB
CC
AP
AR
AP
AS
AU
AT
BT
BT
BP
BQ
AG
AF
AH
AF
AR
AH
AN
AT
AW
AD
AF
AF
AF
AH
1
1
1
1
1
1
1
1
1
1
AD
AE
AD
AD
AB
AE
AT
AE
AC
AE
1
1
1
1
1
1
1
1
AL
AT
AX
AX
AD
AG
AB
AB
CYCLE PARTS
3- 1
3- 1
3- 2
3- 2
3- 3
3- 3
3- 4
3- 4
3- 5
3- 5
3- 6
3- 6
3- 7
3- 7
3- 8
3- 9
3- 9
3-10
3-10
3-11
3-11
3-12
3-13
3-14
3-14
3-15
PCMPRA360JBEZ
PCMPRA359JBEZ
PPIPCF657JB1Z
PPIPCF655JB1Z
PPIPCF656JB1Z
PPIPCF654JB1Z
RHOG-A199JBZZ
RHOG-A198JBZZ
DCON-A166JBKZ
DCON-A167JBKZ
PEVA-A429JBEZ
PEVA-A424JBEZ
GLEG-A103JBE0
GLEG-A105JBE0
PSEL-B161JBE0
PCOV-A371JBE0
PCOV-A321JBE0
PSEL-B160JBE0
PSEL-A971JBE0
DCPY-A235JBKZ
DCPY-A234JBKZ
MSPR-A129JBE0
PGUM-0034JBE0
MSPR-A114JBE0
MSPR-A136JBE0
LPLTMA114JBW0
Compressor [AF-R100CX]
Compressor [AF-R120CX]
Discharge tube [AF-R100CX]
Discharge tube [AF-R120CX]
Suction tube [AF-R100CX]
Suction tube [AF-R120CX]
Overload relay [AF-R100CX]
Overload relay [AF-R120CX]
Condenser ass’y [AF-R100CX]
Condenser ass’y [AF-R120CX]
Evaporator [AF-R100CX]
Evaporator [AF-R120CX]
Compressor cushion [AF-R100CX]
Compressor cushion [AF-R120CX]
Gasket washer [AF-R100CX]
Terminal cover [AF-R100CX]
Terminal cover [AF-R120CX]
Terminal gasket [AF-R100CX]
Terminal gasket [AF-R120CX]
Capillary tube ass’y [AF-R100CX]
Capillary tube ass’y [AF-R120CX)
Cycle spring
Damper rubber
Protector spring [AF-R100CX]
Protector spring [AF-R120CX]
Condenser stay
4- 1
4- 2
4- 3
4- 4
4- 5
4- 6
4- 7
4- 8
4- 9
4-10
TINSEA320JBRZ
PSEL-A349JBE0
PSEL-A350JBE0
PSEL-B365JBE0
TCAD-A351JBEZ
DX-BZA027JBK0
CRMC-A526JBEZ
LHLD-A389JBFB
SSAKAA017YDE0
UBATUA027JBE0
Operation manual
Window insulator
Window insulator
Window insulator
Consummer card
Screws kit
Remote control
Controller holder
Bag
Battery pack
55555555-
CPADBA688YDK0
CPADBA009JBK0
SPAKCA986JBEZ
SPAKCA985JBEZ
SSAKHA314YDE0
PPAK-A007JBE0
TLABMA309JBRZ
SSAKAA053YDE0
Top pad ass’y
Bottom pad ass’y
Packing case [AF-R100CX]
Packing case [AF-R120CX]
Protect
Inner packing
Feature card
Bag
ACCESSORY PARTS
PACKING PARTS
1
2
3
3
4
5
6
7
29
AF-R100CX
AF-R120CX
REF. NO.
PART NO.
DESCRIPTION
Q'TY
CODE
SCREWS AND NUTS
6- 1
6- 2
6- 3
6- 4
6- 4
6- 5
6- 6
6- 7
6- 8
6- 9
6-10
6-11
6-12
6-13
6-14
XTTSD40P12000
LX-BZA236JBE0
XHTSD40P08000
LX-NZA148JBE0
LX-NZA136JBE0
LX-HZA001JBE0
XCTSD40P10000
LX-NZA074JBE0
LX-NZA028JBE0
XTPSD40P08000
XCTSD40P06000
XBPSD40P12J00
LX-CZA038WRE0
XHTSD40P10000
XTPSD40P12000
Tapping screw
Special screw
Tap tight screw
Special nut [AF-R100CX]
Special nut [AF-R120CX]
Special screw
Tapping screw
Special nut
Special nut
Tapping screw
Tapping screw
Machine screw
Special screw
Tap tight screw
Tapping screw
22
1
8
1
1
6
19
1
3
3
16
2
6
2
2
AA
AC
AA
AD
AL
AB
AA
AB
AB
AA
AA
AB
AA
AA
AA
HOW TO ORDER REPLACEMENT PARTS
To have your order filled promptly and correctly, please furnish the following information.
1. MODEL NUMBER
3. PART NO.
2
A
2. REF. NO.
4. DESCRIPTION
3
4
5
6-3
6-3
CONTROL BOX PARTS
6
6-13
2-8
A
6-3
2-10
2-2
6-3
2-14
6-3
2-11
B
2-1
B
6-9
1-5
2-9
1-57
2-7
C
C
2-3
6-11
2-4
6-14
D
2-15
2-12
2
2-4
2-13
2-6
6-1
6-3
3
4
30
5
6
D
H
1
2
3
4
31
6-1
5
1-6
1-62
1-53
1-51
1-48 6-1
1-22
1-47
1-49
1-17
1-20
1-45
1-59
1-56
1-56
6-6
1-1
1-19
1-21
1-41
1-42
1-11
6-7
1-14
1-4
6-1
1-52
6-12
1-40
1-23
6-12
1-2
1-34
6-6
6-6
6-6
1-43
5-2
6-1
1-43
5-1
6-12
6-6
6-6
1-15
6-5
1-18 6-6
5-7
1-33
2-4
6-5
5-4
6-12
1-3
6-5
1-25
1-28
5-3
4
1-12
1-16
1-55
1-10
6-5 1-63
6-5
6-1 6-6
6-12
1-14
6-10
6-1
1-60
1-24
3
6-2
5-6
6-6
6-1
1-39
1-42
1-41
1-46
1-8
2
1-27
1-7
6-1
F
1-54
1-26
1-13
4-5
1-31
D
1-37
1-38
E
1-30
4-2
1-4
4-3
4-1
6-6
1-29
1
1-58
4-6
4-4
4-7
4-10
C
5-5
4-8
B
1-38 1-36
1-37
4-9
A
1-50
1-32
G
1-35
AF-R100CX
AF-R120CX
CABINET PARTS
5
6
A
B
C
D
E
F
G
H
6
AF-R100CX
AF-R120CX
2
1
A
3
CYCLE PARTS
4
5
6
A
6-4
3-8
3-9
3-14
2-7
3-4
3-10
B
B
1-44
6-10
3-5
3-2
C
C
3-15
3-13
6-10
3-3
3-12
6-10
6-1
3-11
3-1
D
D
2-6
6-3
3-6
6-8
3-7
1-61
6-1
6-4
1-9
2-5
6-1
3-9
3-14
AF-R100CX
E
2-7
3-4
3-10
E
1-44
6-10
3-5
3-11
F
F
3-2
3-13
3-15
3-12
6-10
3-1
3-3
6-10
G
G
6-1
6-1
2-6
3-6
6-3
6-8
3-7
1-61
6-1
6-1
1-9
2-5
H
H
AF-R120CX
1
2
3
4
32
5
6
'02 SHARP CORP. (2S0.85E) Printed in U.S.A.