Technical
Information
Model and Manufacturing
numbers listed on page 3.
40" 80% Gas Furnaces
GUIS, GCIS
• Refer to Service Manual RS6600001 Rev. 1 for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in
the Service Manual.
• Refer to the appropriate Parts Catalog for part number
information.
D E SI G N
This manual replaces RT6621005 Rev. 0 April 2000.
REV. 1 - Corrections made to manual, no new models added.
CE RT I F I E D
CE
R TIFIE D
Heating&Air Conditioning
®
Built Better Tha n It Ha s To Be
This manual is to be used by qualified HVAC technicians only. Amana
does not assume any responsibility for property damage or personal injury
due to improper service procedures performed by an unqualified person.
RT6621005
Revision 1
September 2000
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing.
When engineering and manufacturing changes take place where interchangeability of components are affected, the
manufacturing number will change.
It is very important to use the model and manufacturing numbers at all times when requesting service or parts information.
G
U
I
S
045 C A 50
Product Type
Airflow Capability
30: 3.0 Tons
G: Gas Furnace
35: 3.5 Tons
50: 5.0 Tons
Supply Type
U: Upflow/Horizontal
C: Counterflow/Horizontal
Additional Features *
A: Not NOx Certified
Furnace Type
I: Induced Draft (80%)
X: NOx Models
Design Series
A: Initial Design
Model Family
B: Second Design Series
S: Air Command 80 SSE II Category1
C: Third Design Series
D: Fourth Design Series
Nominal Input
045:
45,000 Btuh
070:
70,000 Btuh
090:
90,000 Btuh
115:
115,000 Btuh
140:
140,000 Btuh
WARNING
CAUTION
IF REPAIRS ARE ATTEMPTED BY UNQUALIFIED PERSONS, DANGEROUS CONDITIONS (SUCH AS EXPOSURE TO ELECTRICAL SHOCK) MAY
RESULT. THIS MAY CAUSE SERIOUS INJURY OR DEATH.
AMANA WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY
DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES. IF YOU PERFORM SERVICE ON YOUR OWN PRODUCT, YOU ASSUME RESPONSIBILITY
FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICH MAY RESULT.
2 Rev. 1
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing.
When engineering and manufacturing changes take place where interchangeability of components are affected, the
manufacturing number will change.
It is very important to use the model and manufacturing numbers at all times when requesting service or parts information.
MODEL
M/N
MODEL
M/N
GUIS070CA35
GUIS090CA30
GUIS090CA50
GUIS115CA50
GUIS140CA50
P1211003F
P1211004F
P1211005F
P1211007F
P1211008F
GUIS070CX35
GUIS090CX30
GUIS090CX50
GUIS115CX50
P1230003F
P1230004F
P1230005F
P1230007F
GUIS070CX35
GUIS090CX30
GUIS090CX50
GUIS115CX50
P1211103F
P1211104F
P1211105F
P1211107F
GUIS070CX35 P1230103F
GUIS090CX50 P1230105F
GUIS115CX50 P1230107F
GCIS070CX35 P1211203F
GCIS090CX50 P1211205F
GUIS070DA35 P1227103F
GUIS070CA35
GUIS090CA30
GUIS090CA50
GUIS115CA50
P1229803F
P1229804F
P1229805F
P1229807F
GCIS070CX35 P1230603F
GCIS090CX50 P1230605F
GCIS070CX35 P1230703F
GCIS090CX50 P1230705F
GUIS070CA35 P1229903F
GUIS090CA50 P1229905F
GUIS115CA50 P1229907F
3 Rev. 1
PRODUCT DESIGN
General Operation
This GUIS/GCIS furnace is equipped with an electronic
ignition device to light the burners and an induced draft
blower to exhaust combustion products.
Location Considerations
•
The furnace should be as centralized as is practical
with respect to the air distribution system.
An interlock switch prevents furnace operation if the blower
door is not in place. Keep the blower access doors in place
except for inspection and maintenance.
This furnace is also equipped with a self-diagnosing electronic control module. In the event a furnace component is
not operating properly, the control module LED will flash
on and off in a factory-programmed sequence, depending
on the problem encountered. This light can be viewed
through the observation window in the blower access door.
Refer to the Troubleshooting Chart for further explanation
of the LED codes and Abnormal Operation - Integrated
Ignition Control section in the Service Instructions for an
explanation of the possible problem.
The rated heating capacity of the furnace should be greater
than or equal to the total heat loss of the area to be heated.
The total heat loss should be calculated by an approved
method or in accordance with “ASHRAE Guide” or “Manual
J-Load Calculations” published by the Air Conditioning Contractors of America.
•
Do not install the furnace directly on carpeting, tile,
or combustible material other than wood flooring.
•
When suspending the furnace from rafters or joists,
use 3/8" threaded rod and 2” x 2” x 3/8” angle as
shown in the Installation and Service Instructions.
The length of the rod will depend on the application
and clearance necessary.
•
When installed in a residential garage, the furnace
must be positioned so the burners and ignition source
are located not less than 18 inches (457 mm) above
the floor and protected from physical damage by vehicles.
Accessibility Clearances (Minimum)
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
(INCHES)
UPFLOW
HORIZONTAL
RIGHT
Alcove
6
0
1
6
0
6
12
LEFT
0
0
12
6
REAR
0
0
0
0
TOP
1
1
6
6
FLUE
6
C
2
6
C
2
6
C
FLOOR
2
1
HORIZONTAL
LEFT
Alcove
RIGHT
FRONT
*Obtain from: American National Standards Institute 1430
Broadway New York, NY 10018
COUNTERFLOW
6
NC
1
= 3 inch when using Type B-1 vent is used.
2
= 1 inch when Type B-1 vent is used.
2
C = If placed on combustible floor, floor MUST be wood ONLY.
NC = If placed on combustible floor, floor MUST be wood ONLY.
Counterflow installations on a combustible floor only when installed on special base ASB01.
36" at front is required for servicing or cleaning.
Note: In all cases accessibility clearance shall take precedence over clearances from the enclosure where accessibility clearances are greater. All dimensions are given in
inches.
4 Rev. 1
PRODUCT DESIGN
High Altitude Derate
When this furnace is installed at high altitude, the appropriate High Altitude orifice kit must be installed. This is required due to the natural reduction in the density of both
the gas fuel and combustion air as altitude increases. The
kit will provide the proper design certified input rate within
the specified altitude range.
PROPANE AND HIGH ALTITUDE KITS
MODEL
NUMBER
0 to
7000 ft.
3001 to
7000 ft.
7001 to
8500 ft.
7001 to
8500 ft.
GUIS070
LPTK09
Propane
Conversion Kit
(#55 Orifice)
HATS01
High Altitude
Natural Gas Kit
(#44 Orifice)
HATS06
High Altitude
Orifice Kit
(#45 Orifice)
HALP09
High Altitude
Propane Gas Kit
(#56 Orifice)
GCIS070
LPTK09
Propane
Conversion Kit
(#55 Orifice)
HATS05
High Altitude
Natural Gas Kit
(#44 Orifice)
HATS09
High Altitude
Orifice Kit
(#45 Orifice)
HALP09
High Altitude
Propane Gas Kit
(#56 Orifice)
GUIS090
LPTK09
Propane
Conversion Kit
(#55 Orifice)
HATS02
High Altitude
Natural Gas Kit
(#44 Orifice)
HATS06
High Altitude
Orifice Kit
(#45 Orifice)
HALP09
High Altitude
Propane Gas Kit
(#56 Orifice)
GCIS090
LPTK09
Propane
Conversion Kit
(#55 Orifice)
HATS05
High Altitude
Natural Gas Kit
(#44 Orifice)
HATS09
High Altitude
Orifice Kit
(#45 Orifice)
HALP09
High Altitude
Propane Gas Kit
(#56 Orifice)
GUIS115
LPTK09
Propane
Conversion Kit
(#55 Orifice)
HATS03
High Altitude
Natural Gas Kit
(#44 Orifice)
HATS07
High Altitude
Orifice Kit
(#45 Orifice)
HALP09
High Altitude
Propane Gas Kit
(#56 Orifice)
GUIS140
LPTK09
Propane
Conversion Kit
(#55 Orifice)
HATS04
High Altitude
Natural Gas Kit
(#44 Orifice)
HATS08
High Altitude
Orifice Kit
(#45 Orifice)
HALP09
High Altitude
Propane Gas Kit
(#56 Orifice)
High altitude kits are purchased according to the installation altitude and usage of either natural or propane gas.
Refer to the chart above for a tabular listing of appropriate
altitude ranges and corresponding manufacturer’s high altitude Natural Gas and Propane Gas kits. For a tabular
listing of appropriate altitude ranges and corresponding
manufacturer's High Altitude Pressure Switch kits, refer to
either the Pressure Switch Trip Points & Usage Chart in
this manual or the Accessory Charts in Service Instructions.
Note: For propane gas installations, the LPTK09 conversion kit has the required orifices
for installations up to 7,000 feet. For Propane gas installations between 3,001 and 7,000
feet, the HATS kits listed above are required for the pressure switch change.
5 Rev. 1
PRODUCT DIMENSIONS
GUIS 80% Upflow/Horizontal
UPFLOW
LEFT SIDE VIEW
28 3/4
A
KNOCK-OUT
FOR HORIZONTAL
VENTING
28
3/4
UPFLOW
RIGHT SIDE VIEW
UPFLOW
FRONT VIEW
20 1/8
B
3/4
4 3/4
3/4
C
4 5/8
1 3/4
ELECTRICAL
HOLE "HIGH
VOLTAGE"
SUPPLY
ELECTRICAL
HOLE "LOW
VOLTAGE"
SUPPLY
GAS
SUPPLY
HOLE
A Raytheon Company
40
4 5/8
31
37 3/8
23
34 5/8
31 5/8
28 1/4
14
SIDE
KNOCK-OUT
SIDE
KNOCK-OUT
1 5/8
1 5/8
23
BOTTOM
KNOCK-OUT
D
BOTTOM
KNOCK-OUT
GUIS DIMENSIONS
B
C
D
E
Minimum
Vent
Diameter
GUIS070 16-1/2
15
5-1/4
12-5/8
4
4
GUIS090
20-1/2
19
7-1/4
14-5/8
4
4
GUIS115
GUIS140
24-1/2
23
9-1/4
18-5/8
4
5
FURNACE
MODEL
A
All dimensions are in inches.
6 Rev. 1
PRODUCT DIMENSIONS
GCIS 80% Counterflow/Horizontal
COUNTERFLOW
FRONT VIEW
A
3/4
COUNTERFLOW
RIGHT SIDE VIEW
COUNTERFLOW
LEFT SIDE VIEW
28 3/4
B
3/4
28
20 1/8
3/4
3"
4 3/4
22
28 1/4
4 5/8
31 5/8
34 5/8
KNOCK-OUT
FOR HORIZONTAL
VENTING
40
31
GAS
SUPPLY
HOLE
A Raytheo nC ompan y
SUPPLY
ELECTRICAL
HOLE "LOW
VOLTAGE"
18 5/8
UNFOLDED
FLANGES
20 1/8
FOLDED
FLANGES
D
UNFOLDED
FLANGES
E
FOLDED
FLANGES
SUPPLY
ELECTRICAL
HOLE "HIGH
VOLTAGE"
1 3/4
2 1/2
Units are shipped with
unfolded bottom flanges.
4 5/8
GCIS DIMENSIONS
FURNACE
MODEL
A
B
C
D
Unfolded
E
Folded
Minimum
Vent
Diameter
GCIS070
16-1/2
15
5/3/8
13-1/2
15
4
GCIS090
20-1/2
19
7-3/8
17-1/2
19
4
All dimensions are in inches.
7 Rev. 1
PRODUCT DESIGN
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
NEGATIVE
PRESSURE
ID BLOWER
WITH FLUE
NOT FIRING
TYPICAL SEA
LEVEL DATA
LOW
HIGH
FIRE
FIRE
NEGATIVE
PRESSURE
ID BLOWER
WITH FLUE
FIRING
TYPICAL SEA
LEVEL DATA
LOW
HIGH
FIRE
FIRE
GUIS070**35
-0.50
-0.90
-0.52
-0.85
GUIS090**30/50
-0.42
-0.9
-0.44
-0.79
GUIS115**50
-0.42
-0.85
-0.42
-0.71
GUIS140**50
-0.37
-0.85
-0.39
-0.71
GCIS070**35
-0.32
-0.80
-0.37
-0.60
GCIS090**50
-0.32
-0.80
-0.37
-0.60
MODEL
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
0 to 3,000 feet
MODEL
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
LOW
HIGH
FIRE
FIRE
3,001 to 7,000 feet
ID BLOWER
PRESSURE
SWITCH
PART #
PS1
LABEL
COLOR
PS2
LABEL
COLOR
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
LOW
HIGH
FIRE
FIRE
HIGH
ALTITUDE
KIT
PS1
LABEL
COLOR
7,001 to 8,500 feet
PS2
LABEL
COLOR
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
LOW
HIGH
FIRE
FIRE
HIGH
ALTITUDE
KIT
PS1
LABEL
COLOR
PS2
LABEL
COLOR
GUIS070**35
-0.45
-0.80
11177103
DK BLUE
ORANGE
-0.37
-0.66
HATS01
11177105
PURPLE
WHITE
-0.32
-0.55
HATS06
11177108
RED
GRAY
GUIS090**30/50
-0.37
-0.74
11177102
PURPLE
YELLOW
-0.37
-0.60
HATS02
11177106
PURPLE
LT BLUE
-0.32
-0.55
HATS06
11177108
RED
GRAY
GUIS115**50
-0.37
-0.66
11177105
PURPLE
WHITE
-0.37
-0.55
HATS03
11177107
PURPLE
GRAY
-0.32
-0.46
HATS07
11177110
RED
PINK
GUIS140**50
-0.32
-0.66
11177104
RED
WHITE
-0.32
-0.55
HATS04
11177108
RED
GRAY
-0.27
-0.46
HATS08
11177109
GREEN
PINK
GCIS070**35
-0.27
-0.55
11177101
GREEN
GRAY
-0.27
-0.46
HATS05
11177109
GREEN
GRAY
-0.23
-0.37
HATS09
11177111
GRAY
DK BLUE
GCIS090**50
-0.27
-0.55
11177101
GREEN
GRAY
-0.27
-0.46
HATS05
11177109
GREEN
GRAY
-0.23
-0.37
HATS09
11177111
GRAY
DK BLUE
Note: All installations above 3,000 ft. require a pressure switch change. For installations in Canada the Amana 80% furnace is certified only to 4500.ft.
Note: Replacement pressure switch number is listed below high altitude kit number.
Note: All negative pressure readings are in inches of water column (" w.c.).
8 Rev. 1
PRODUCT DESIGN
T.O.D. PRIMARY LIMIT
Part Number
10728306 10728319 10728325 10728330 10728331
Open Setting °F
200
170
170
200
160
Style
2
2
3
3
3
Black
Blue
Blue
Tan
Brown
Sleeve Colors
GUIS070**35
1
GUIS090**30/50
1
GUIS115**50
1
GUIS140**50
1
GCIS070**35
1
GCIS090**50
1
ROLLOUT LIMIT SWITCHES
Part Number
Open Setting °F
Color
GUIS070**35
GUIS090**30/50
GUIS115**50
GUIS140**50
10123508
or
10123527
260
10123509
or
10123531
275
10123510
or
10123529
300
10123512
or
10123531
325
BROWN
PINK
LT GREEN
LT PURPLE
1
1
1
1
GCIS070**35
GCIS090**50
1
1
AUXILIARY LIMIT SWITCHES
Part Number
10123506
or
10123525
10123516
or
10123535
Open Setting °F
160
150
Color
Orange
Red
GUIS070**35
1
GUIS090**30/50
1
GUIS115**50
1
GUIS140**50
1
GCIS070**35
1
GCIS090**50
1
9 Rev. 1
PRODUCT DESIGN
Coil Matches:
A large array of Amana coils are available for use with the GUIS and GCIS furnaces, in either upflow, counterflow, or
horizontal applications. These coils are available in both cased and uncased models, with or without a TXV expansion
device. These 80% furnaces match up with the existing Amana coils as shown in the chart below.
Btuh
Input
70,000
90,000
115,000
Cabinet Air Flow
Width
(tons)
16 1/2"
20 1/2"
24 1/2"
CCA_F*C
Cased
A-Coils
CCA18FCC
CCA24FCC
1 1/2 - 4 CCA30FCC
CCA36FCC
CCA42FCC
CCA_FSC
Uncased
A-Coils
CHA_TCC
Cased
TXV A-Coils
CHA_TSC
Uncased
TXV A-Coils
CCF_F*C
Horiz.
A-Coils
CHF_TCC
Horiz.
A-Coils
CCA18FSC
CCA24FSC
CCA30FSC
CCA36FSC
CCA42FSC
CHA18TCC
CHA24TCC
CHA30TCC
CHA36TCC
CHA18TSC
CHA24TSC
CHA30TSC
CHA36TSC
CCF24FCC
CCF30FCC
CHF18TCC
CHF24TCC
CHF30TCC
CCA30FDC
CCA36FDC
CCA48FSC
CCA42FDC
CCA48FCC
CHA42TCC
CHA42TSC
CCF24FDC
CCF36FDC CHF36TCC
CCF42FCC CHF42TCC
CCF48FCC
CCA36FKC
CCA48FDC CCA54FSC
2 1/2 - 5 CCA54FCC CCA57FSC
CCA57FCC CCA60FSC
CCA60FCC
CHA48TCC
CHA54TCC
CHA57TCC
CHA60TCC
CHA48TSC
CHA54TSC
CHA57TSC
CHA60TSC
CCF48FDC
CHF48TCC
CCF60FCC
CHF60TCC
CCF61FCC
2-5
Thermostats:
The following Amana Thermostats are suggested for use with the GUIS and GCIS Furnace Models:
Thermostats (Two-Stage Applications)
Thermostat
Man/Auto
Programmable
Cool
Heat
Batt. Powered
Batt. Bkup*
Shape
Color
1217701
Man. Changeover
No
2
2
No
No
Rectangular
Beige
1213407
Man. Changeover
Yes
2
2
No
Yes
Rectangular
White
*1213407 is 24V powered with battery backup.
Thermostats (Dual Fuel Applications)
Thermostat
Man/Auto
Programmable
Cool
Heat
Batt. Powered
Batt. Bkup*
Shape
Color
1213406
Man. Or Auto
Yes
2
3
No
Yes
Rectangular
White
*1213406 is 24V powered with battery backup.
Note: The above thermostat 1213406 is the recommended model for the GUIS and GCIS furnaces when used with a heat pump in a
fossil fuel application. It is not for use with the GUIS or GCIS furnace as a sole heating source.
10 Rev. 1
FURNACE SPECIFICATIONS
MODEL
Btuh Input (US) High Fire
GUIS070CA35
GUIS070CX35
GUIS070DA35
GUIS090CA30
GUIS090CX30
GUIS090CA50
GUIS090CX50
GUIS115CA50
GUIS140CA50
69,000
92,000
92,000
115,000
138,000
Output (US) High Fire
55,200
73,600
73,600
92,000
110,400
Btuh Input (US) Low Fire
48,000
64,000
64,000
80,000
96,000
Output (US) Low Fire
38,400
51,200
51,200
64,000
76,800
80%
80%
80%
80%
80%
Rated External Static (" w.c.)
.10 - .50
.10 - .50
.10 - .50
.10 - .50
.10 - .50
Temperature Rise (°F)
30 - 60
35 - 65
35 - 65
35 - 65
45 - 75
A.F.U.E.
High Stage Pressure Switch Trip Point (" w.c.)
-0.80
-0.74
-0.74
-0.66
-0.66
Low Stage Pressure Switch Trip Point (" w.c.)
-0.45
-0.37
-0.37
-0.37
-0.32
Blower Wheel (D" x W")
10 X 6
10 X 8
10 X 8
10 X 9
10 X 9
1/2
1/2
1/2
3/4
3/4
Blower Horsepower
Blower Speeds
Max CFM @ 0.5 E.S.P.
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
4
4
4
4
4
1450
1380
1975
1985
2050
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
10.9
8.0
14.4
13.5
14.4
15
15
15
15
15
Transformer (VA)
40
40
40
40
40
Heat Anticipator (Amps)
0.7
0.7
0.7
0.7
0.7
Primary Limit Setting (°F)
230
220
170
190
160
Auxiliary Limit Setting (°F)
160
160
160
160
160
Rollout Limit Setting (°F)
260
300
300
325
325
30 secs.
30 secs.
30 secs.
30 secs.
30 secs.
Off Heating *
90 secs.
90 secs.
90 secs.
90 secs.
90 secs.
Off Cooling
45 secs.
45 secs.
45 secs.
45 secs.
45 secs.
Fan Delay On
Gas Supply Pressure (Natural/Propane) ("w.c.)
Manifold Pressure (Natural/Propane) High Stage (" w.c.)
7 / 11
7 / 11
7 / 11
7 / 11
7 / 11
3.5 / 10
3.5 / 10
3.5 / 10
3.5 / 10
3.5 / 10
Manifold Pressure (Natural/Propane) Low Stage ("w.c.)
1.9 / 6.0
1.9 / 6.0
1.9 / 6.0
1.9 / 6.0
1.9 / 6.0
Orifice Size (Natural/Propane)
#43 / #55
#43 / #55
#43 / #55
#43 / #55
#43 / #55
Number of Burners
3
4
4
5
6
Vent Connector Diameter (inches)
4
4
4
4
4
152
169
178
194
198
Shipping Weight (lbs.)
* Off Heating - This fan delay timing is adjustable (60, 90, 120 or 180 seconds), 90 seconds as shipped.
1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane
gas operation.
2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace
must not be derated, orifice changes should only be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers
method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the
AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less
than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output.
4. Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
11 Rev. 1
FURNACE SPECIFICATIONS
MODEL
GCIS070CX35
GCIS090CX50
Btuh Input (US) High Fire
69,000
92,000
Output (US) High Fire
55,200
73,600
Btuh Input (US) Low Fire
48,000
64,000
Output (US) Low Fire
38,400
51,200
80%
80%
Rated External Static (" w.c.)
A.F.U.E.
.10 - .50
.10 - .50
Temperature Rise (°F)
35 - 65
45 - 75
-0.55
-0.55
High Stage Pressure Switch Trip Point (" w.c.)
Low Stage Pressure Switch Trip Point (" w.c.)
-0.27
-0.27
Blower Wheel (D" x W")
10 X 6
10 X 8
Blower Horsepower
1/2
3/4
Blower Speeds
4
4
Max CFM @ 0.5 E.S.P.
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
1366
1780
115-60-1
115-60-2
10.2
14.2
15
15
Transformer (VA)
40
40
Heat Anticipator (Amps)
0.7
0.7
Primary Limit Setting (°F)
190
160
Auxiliary Limit Setting (°F)
160
160
Rollout Limit Setting (°F)
275
275
30 secs.
30 secs.
Off Heating *
90 secs.
90 secs.
Off Cooling
45 secs.
45 secs.
Fan Delay On
Gas Supply Pressure (Natural/Propane) ("w.c.)
Manifold Pressure (Natural/Propane) High Stage ("w.c.)
7 / 11
7 / 11
3.5 / 10
3.5 / 10
Manifold Pressure (Natural/Propane) Low Stage ("w.c.)
1.9 / 6.0
1.9 / 6.0
Orifice Size (Natural/Propane)
#43 / #55
#43 / #55
3
4
Number of Burners
Vent Connector Diameter
Shipping Weight (lbs.)
3
3
152
178
* Off Heating - This fan delay timing is adjustable (60, 90, 120 or 180 seconds), 90 seconds as shipped.
1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane
gas operation.
2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace
must not be derated, orifice changes should only be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers
method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the
AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less
than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output.
4. Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
12 Rev. 1
BLOWER PERFORMANCE SPECIFICATIONS
(CFM & Temperature Rise vs. External Static Pressure)
Model
(
)
MOTOR
SPEED
GUIS070_35
(30-60)
High Fire: Med-Lo
Low Fire: Low
GUIS090_30
(35-65)
High Fire: High
Low Fire: Med-Lo
GUIS090_50
(35-65)
High Fire: Med-Lo
Low Fire: Low
GUIS115_50
(35-65)
High Fire: Med-Lo
Low Fire: Low
GUIS140_50
(45-75)
High Fire: Med
Low Fire: Low
GCIS070_35
(35-65)
High Fire: Med-Lo
Low Fire: Low
GCIS090_50
(45-75)
High Fire: Med-Lo
Low Fire: Low
HIGH
MED
MED-LO
LOW
HIGH
MED
MED-LO
LOW
HIGH
MED
MED-LO
LOW
HIGH
MED
MED-LO
LOW
HIGH
MED
MED-LO
LOW
HIGH
MED
MED-LO
LOW
HIGH
MED
MED-LO
LOW
Heating Speed
As Shipped
TONS AC
@ 0.5"
0.1
ESP
CFM
RISE
HIGH
FIRE
3.5
3.0
3.0
2.5
3.5
3.0
2.0
1.5
5.0
4.0
3.5
3.0
5.0
5.0
4.0
3.0
5.0
5.0
4.0
3.5
3.5
3.0
3.0
2.5
5.0
4.0
3.5
3.0
1695
1485
1235
1095
1630
1360
920
770
2250
1775
1320
1180
2330
2120
1875
1290
2455
2050
1715
1450
1655
1530
1090
945
2110
1830
1260
1015
30
34
41
47
42
50
------38
52
58
37
40
45
----50
60
70
----47
54
----54
67
0.2
RISE
LOW
FIRE
------33
--35
52
62
----36
40
------46
------49
------38
------47
External Static Pressure, Inches Water Column
0.3
0.4
CFM
RISE
HIGH
FIRE
RISE
LOW
FIRE
1625
1450
1200
1070
1560
1325
920
750
2185
1750
1315
1180
2245
2070
1840
1275
2390
2025
1700
1436
1580
1470
1075
935
2030
1765
1255
1000
31
35
43
48
44
51
------39
52
58
38
41
46
----50
60
71
--35
48
55
----54
68
----30
33
--36
52
64
----36
40
------47
------50
------38
------48
CFM
RISE
HIGH
FIRE
RISE
LOW
FIRE
1580
1400
1180
1050
1550
1290
900
740
2120
1735
1315
1175
2165
2020
1800
1250
2290
1965
1660
1413
1500
1400
1055
915
1960
1710
1230
980
32
37
43
49
44
53
------39
52
58
39
42
47
--45
52
62
72
--37
48
56
----55
70
----30
34
--37
53
64
----36
41
------48
------51
------39
------49
0.5
CFM
RISE
HIGH
FIRE
RISE
LOW
FIRE
1520
1350
1140
1025
1465
1215
890
730
2030
1690
1315
1170
2065
1940
1735
1235
2200
1890
1615
1380
1445
1345
1015
890
1870
1640
1200
964
34
38
45
50
47
56
------40
52
58
41
44
49
--46
54
63
74
35
38
50
57
----57
71
----31
35
--39
54
65
----36
41
------48
------52
----35
40
------49
0.6
CFM
RISE
HIGH
FIRE
RISE
LOW
FIRE
CFM
1450
1295
1115
975
1380
1155
850
690
1975
1650
1280
1140
1985
1850
1685
1210
2050
1810
1555
1338
1366
1280
975
850
1780
1550
1170
930
35
39
46
52
49
59
----35
41
53
60
43
46
51
--50
56
66
37
40
52
60
----58
73
----32
37
35
41
56
------37
42
----35
49
----46
53
----37
42
------51
1365
1235
1050
950
1275
1070
800
660
1885
1600
1240
1120
1885
1775
1600
1170
1935
1715
1472
1280
1280
1210
915
810
1680
1470
1115
875
1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the
furnace requires two return filters, this chart assumes both filters are installed.
2. Blower speeds for each firing rate are set independant of each other.
3. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed.
4. For most jobs, about 400 CFM per ton when cooling is desirable.
5. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON
THE RATING PLATE.
6. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown
on rating plate. The shaded area indicates ranges in excess of maximum external static pressure allowed when
heating.
7
The dashed (---) areas indicate a temperature rise not recommended for this model.
8. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have
approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
13 Rev. 1
BLOWER PERFORMANCE SPECIFICATIONS
14 Rev. 1
BTU OUTPUT vs TEMPERATURE RISE CHART
100
600 CFM
90
700
80
800
TEMPERATURE RISE
900
1000
70
1100
1200
60
1400
1600
50
1800
2000
2200
2400 CFM
40
30
FORMULAS
BTU OUTPUT = CFM x 1.08 x RISE
BTU OUTPUT
RISE =
÷ CFM
1.08
20
10
30
40
50
60
70
80
90
100
OUTPUT BTU/HR x 1000
110
120
130
140
150
Y
7
(PS1) PRESSURE
SWITCH (LOW)
(PS2) PRESSURE
SWITCH (HIGH)
BR
BR
CONTROL
R
TERMINAL ORDER REARRANGED FOR CLARITY
COM
5
6
** *
X X
MF
F M
RR
M
V
C
HNH NH HN
P H H MC MP O
OEO E OOE T T S L L V OV S O
T UT UT T U RH1 I OL MH2 L
*
P
A
R
K
**
H
E
A
T
L
O
H
I
E
I
N
A
G
D
G i
T I N
HG- F N H
I NN P D I
C
I
R
N
E
U
COOL
5
HI
3
OR-20
C
2
BR-21
PM 1
GY-47
GAS
VALVE
(GV)
GY-47
YL-11
BU-12
HEAT-HI
BK-6
BK-1
LINE
XMFR
EAC
HUM
GN
IGN
IND-HI
HUM
MVH
EAC
PS2
CIR
GND
XFMR
WH-33
FP
LINE
TH
IND-N
IGN-N
AUX LIMIT
HLI
IND-LO
PRIMARY
ROLLOUT LIMIT (RL)
PRIMARY
LIMIT
BK
RD
WH
MVMVL
COM
BU-25
VT-15
CONTROL
TR
RD-14
HEAT-LO
HLO GND
VT
-16
COMB
BLOWER
(CB)
6
OR-19
PARK
*
**
PS1
C
***
WH
CAPACITOR
(CAP)
NC
RD-18
I
G
N
I
T
O
R
NO
BU
-12
NO
NEUTRAL 120VAC
8
NC
BK-6
BU-36
WH-23
ON
PRIMARY
LIMIT
PRIMARY
RL
AUX LIMIT
F
L
A
M
E
VC 2
A
L
V HI 3
E
S
E
N
S
O
R
CB
C
DOOR SWITCH (CLOSED
WHEN DOOR IN PLACE)
L1
NO
DOOR
SWITCH
PS2
N
CAP
C
GND
ELECTRICAL BOX
FACTORY WIRED BLOWER MOTOR TO CONTROL CONNECTIONS
FURNACE MODEL
* MANUFACTURER'S
VARIABLE LETTER
HIGH STAGE
MOTOR
SPEEDS
**
MOTOR
TO HEAT
LOW STAGE
MOTOR
SPEEDS
*
MOTOR
TO HEAT
GUIS070C*35
MED LOW
OR-29
GUIS090C*30
HIGH
BK-26
GUIS090C*50
MED LOW
OR-29
LOW
RD-24
GUIS115C*50
MED LOW
OR-29
LOW
RD-24
GUIS140C*50
MED HI
BU-23
LOW
RD-24
GCIS070C*35
MED LOW
OR-29
LOW
RD-24
GCIS090C*50
MED LOW
OR-29
LOW
RD-24
15 Rev. 1
! WARNING
LOW
MED-LO
*** COOLING
BLOWER SPEED
RD-24
0R-29
115V FIELD
CONNECT
HUMIDIFIER
SEE
INSTALLATION
INSTRUCTIONS
TO DETERMINE
PROPER
COOLING
BLOWER SPEED.
12
9
6
11
8
5
2
10
7
4
1
W1 W2
Y
R
G
B
RD-18
GN
LINE
TRANSFORMER
BR-21
OR-19
GY-47
YL-11
WH
N
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
WH-2
LOAD
L1
GND
NC
BK-1
BK-3
ACB
NO
THERMOSTAT
CONNECTIONS
IGNITOR
115V
FIELD
CONNECT
WH-2
BK-6
RD22
FLAME SENSOR
7
BK-1
WH-23
G
APM 1
S
WARNING:DISCONNECT POWER
BEFORE SERVICING.WIRING TO
UNIT MUST BE PROPERLY
POLARIZED AND GROUNDED.
COLOR CODE
YL YELLOW
OR ORANGE
VT VIOLET
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BU BLUE
GY GRAY
RD RED
LOW VOLTAGE
LOW VOLTAGE FIELD
HI VOLTAGE
HI VOLTAGE FIELD
BU-12
BU-25
BU-36
OR-3
GY-25
IMPORTANT:
READ BEFORE OPERATING OR SERVICING THIS UNIT
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. AMANA SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST
105°C. USE COPPER CONDUCTORS ONLY.
4. UNUSED BLOWER MOTOR LEADS MUST BE PLACED ON "PARK" TERMINALS OF CONTROL OR TAPED.
5 IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER BEFORE CONNECTING
BLOWER LEADS. USED ONLY IF HIGH STAGE HEAT AND COOLING USE THE SAME SPEED.
6 IF HIGH STAGE HEAT AND LOW STAGE HEAT SPEEDS ARE NOT THE SAME DISCARD
JUMPER BEFORE CONNECTING BLOWER LEADS. USE ONLY
IF HIGH STAGE HEAT AND LOW STAGE HEAT USE THE SAME SPEED.
7 DIAGNOSTIC LIGHT: CONTINUOUS ON = INTERNAL LOCKOUT -REPLACE CONTROL; 1 FLASH = EXTERNAL LOCKOUT - CHECK FURNACE;
2 FLASHES - PRESSURE SWITCH STUCK CLOSED; 3 FLASHES - PRESSURE SWITCH STUCK OPEN; 4 FLASHES - OPEN THERMAL
PROTECTION DEVICE; CONTINUOUS FLASH - FLAME SENSED - NO CALL FOR HEAT STAT RECOVERY (1/4 SEC. ON, 1/4 SEC. OFF).
8 PLUG CONNECT FOR FURNACE TWINNING.
TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY,
OR DEATH, DISCONNECT THE POWER BEFORE SERVICING.
3
1 2
GUIS and GCIS (See model numbers above)
120 V
TRANSFORMER
24 V
PS1
NC
L
I
N
I
E
NI
DN
- D G N
L - N E
ON D U
OR
-19
HOT 120VAC
L
E EH HI
A AU UN
C CM ME
COM
NO
RD
-18
115V FIELD
CONNECT
ELECTRONIC
AIR CLEANER
#26 BK (HI)
#23 BU (MED)
#29 OR (MED LOW)
#24 RD (LOW)
CIRCULATOR BLOWER
G
B
AIR
CIRC
BLOWER
(ACB)
200344 REV. 0
WIRING DIAGRAMS
W1 THERMOSTAT
W2 CONNECTIONS
W2
Y
(PS1) PRESSURE
SWITCH (LOW)
7
(PS2) PRESSURE
SWITCH (HIGH)
BR
BR
CONTROL
R
TERMINAL ORDER REARRANGED FOR CLARITY
COM
5
B
6
***
XX
MF
F M
RR
M
V
HNH NHHN
P H H MC MP
OE O E OOE T T S L L V OV S
T UT UT T U R H1 I OL MH2
**
*
C
O
O
L
P
A
R
K
H
E
A
T
L
O
H
I
E I
N
A G
D
T I N Gi
HG- F NH
I NNP DI
C
I
R
N
E
U
2
BR-21
PM 1
GY-47
C
GAS
VALVE
(GV)
HEAT-HI
LINE
XMFR
EAC
HUM
GN
IGN
IND-HI
CIR
WH-33
EAC
HUM
NC
BK-6
BU-36
8
WH-23
ON
WH-23
G
A PM 1
S
PRIMARY
RL
F
L
A
M
E
V C 2
A
L
V HI 3
E
AUX LIMIT
S
E
N
S
O
R
CB
C
DOOR SWITCH (CLOSED
WHEN DOOR IN PLACE)
L1
NO
DOOR
SWITCH
PS2
N
CAP
C
WH
N
GND
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
ELECTRICAL BOX
FACTORY WIRED BLOWER MOTOR TO CONTROL CONNECTIONS
FURNACE MODEL
* MANUFACTURER'S
VARIABLE LETTER
HIGH STAGE
MOTOR
SPEEDS
**
LOW STAGE
MOTOR
TO HEAT
MOTOR
SPEEDS
LOW
*
MOTOR
TO HEAT
BLOWER SPEED
RD-24
GUIS070*35
MED LOW
OR-29
GUIS090*30
HIGH
BK-26
GUIS090*50
MED LOW
OR-29
LOW
RD-24
GUIS115*50
MED LOW
OR-29
LOW
RD-24
GUIS140*50
MED HI
BU-23
LOW
GCIS070*35
MED LOW
OR-29
LOW
GCIS090*50
MED LOW
OR-29
LOW
MED-LO
*** COOLING
0R-29
SEE
INSTALLATION
INSTRUCTIONS
TO DETERMINE
PROPER
COOLING
BLOWER SPEED.
COLOR CODE
YL YELLOW
OR ORANGE
VT VIOLET
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BU BLUE
GY GRAY
RD RED
LO W VOLTAGE
! WARNING
RD-24
12
9
6
8
5
2
10
7
4
1
3
W1 W2
Y
R
G
B
RD-18
GN
LINE
BR-21
OR-19
GY-47
YL-11
WARNING:DISCONNECT POWER
BEFORE SERVICING.WIRING TO
UNIT MUST BE PROPERLY
POLARIZED AND GROUNDED.
RD-24
RD-24
115V FIELD
CONNECT
HUMIDIFIER
TRANSFORMER
LOAD
L1
GND
NC
WH-2
BK-3
ACB
NO
THERMOSTAT
CONNECTIONS
BK-1
IGNITOR
115V
FIELD
CONNECT
WH-2
BK-6
RD22
FLAME SENSOR
7
BK-1
11
1 2
PRIMARY
LIMIT
PS2 MVH
XFMR
FP
LINE
GND
COMBUSTION
BLOWER
(CB)
IND-N
IGN-N
AUX LIMIT
TH
IND-LO
PRIMARY
ROLLOUT LIMIT (RL)
PRIMARY
LIMIT
BK
RD
WH
HLI
BU-25
VT-15
CONTROL
MVMVL
COM
C
RD-14
HEAT-LO
BK-6
BK-1
TR
NO
6
GY-47
YL-11
BU-12
PARK
*
**
RD-18
OR-19
VT
-16
COOL
5
PS1 HLO GND
I
G
N
I
T
O
R
***
WH
CAPACITOR
(CAP)
NC
OR-20
3
HI
BU
-12
CIRCULATION
BLOWER
(ACB)
NO
NEUTRAL 120VAC
GUIS and GCIS (See model numbers above)
120 V
TRANSFORMER
24 V
PS1
NC
L
I
N
I
E
NI
DN
- DGN
L - NE
ON D U
OR
-19
HOT 120VAC
L
EEH HI
AAU UN
C C M ME
COM
NO
RD
-18
CIRCULATOR BLOWER
G
115V FIELD
CONNECT
ELECTRONIC
AIR CLEANER
#26 BK (HI)
#23 BU (MED)
#29 OR (MED LOW)
#24 RD (LOW)
AIR
WIRING DIAGRAMS
16 Rev. 1
THERMOSTAT
CONNECTIONS
W1
LOW VOLTAGE FIELD
HI VOLTAGE
HI VOLTAGE FIELD
BU-12
BU-25
BU-36
OR-3
GY-25
IMPORTANT:
READ BEFORE OPERATING OR SERVICING THIS UNIT
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. AMANA SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST
105C. USE COPPER CONDUCTORS ONLY.
4. UNUSED BLOWER MOTOR LEADS MUST BE PLACED ON "PARK" TERMINALS OF CONTROL OR TAPED.
5 IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER BEFORE CONNECTING
BLOWER LEADS. USED ONLY IF HIGH STAGE HEAT AND COOLING USE THE SAME SPEED.
6 IF HIGH STAGE HEAT AND LOW STAGE HEAT SPEEDS ARE NOT THE SAME DISCARD
JUMPER BEFORE CONNECTING BLOWER LEADS. USE ONLY
IF HIGH STAGE HEAT AND LOW STAGE HEAT USE THE SAME SPEED.
7 DIAGNOSTIC LIGHT:CONTINUOUS= INTERNAL LOCKOUT-REPLACE CONTROL; 1 FLASH= EXTERNAL LOCKOUTCHECK FURNACE; 2 FLASHES= PRESSURE SWITCH STUCK CLOSED; 3 FLASHES= PRESSURE SWITCH STUCK
OPEN; 4 FLASHES= THERMAL PROTECTION DEVICE OPEN; CONTINUOUS FLASH=FLAME SENSED-NO CALL FOR
HEAT STAT RECOVERY: (1/4 SEC. ON, 1/4 SEC. OFF)
8 PLUG CONNECT FOR FURNACE TWINNING.
TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY,
OR DEATH, DISCONNECT THE POWER BEFORE SERVICING.
20208701 REV. 0
GUIS and GCIS
WR50A51-215 INTEGRATED IGNITION CONTROL
This schematic is for reference only. Not all wiring is as shown above, refer
! WARNING
IGNN
1M
1M
.001
K1
HEAT
HI
IGN
K2
HEAT
LO
K7
PARK
K8
36E
2 STAGE
GAS VALVE
C
H1
P
M
2ND STAGE
PRESSURE
SWITCH
HLO
AUX
LIMIT
HLI
K3B
K9B
MVH
ACN
AIR
CLEANER
HUMN AC
ROLLOUT
SWITCH
1ST STAGE
PRESSURE
SWITCH
HIGH
LIMIT
K4
K3A
K9A
HUMIDIFIER
HUM
PS1
IND
HI
PS2
K3A
IND IND
NEU LO
MVL
GND GND MV
COM
K6
K1
K2
K10
COOL
INDUCER
TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY,
OR DEATH, DISCONNECT THE POWER BEFORE SERVICING.
IGNITOR
FP
FLAME
SENSOR
PROBE
LINE NEU
120 VAC
LINE HOT
CIRCN
CIRCULATOR
BLOWER
TH
G
W1
W2
Y
TR
C
XFMRN
XFMR
R
Y
G
W1
W2
THERMOSTAT
COMPRESSOR
CONTACTOR COIL
24 V.A.C.
R
SCHEMATICS
to the appropriate wiring diagram for the unit being serviced.
17 Rev. 1