3 - Language Dictionary
Measurement Subsystem (Current)
This subsystem programs the current measurement capability of the ac source. Two measurement
commands are available: MEASure and FETCh. MEASure triggers the acquisition of new measurement
data before returning a reading. FETCh returns a reading computed from previously acquired data.
Individual outputs of a three-phase source are specified by the setting of INSTrument:NSELect.
Subsystem Syntax
MEASure | FETCh
[:SCALar]
:CURRent
[:DC]?
:AC?
:ACDC?
:AMPLitude
:MAX?
:CREStfactor?
:HARMonic
[:AMPLitude]? <n>
:PHASe? <n>
:THD?
:NEUTral
[:DC]?
:AC?
:ACDC?
:HARMonic
[:AMPLitude]? <n>
:PHASe? <n>
Returns dc component of the current
Returns ac rms current
Returns ac+dc rms current
Returns peak current
Returns current crestfactor
Returns amplitude of the Nth harmonic of current
Returns phase of the Nth harmonic of current
Returns % of total harmonic distortion of current
Returns neutral dc current (3-phase only)
Returns neutral ac rms current (3-phase only)
Returns neutral ac+dc rms current (3-phase only)
Returns neutral current harmonic amplitude (3-phase only)
Returns neutral current harmonic phase (3-phase only)
MEASure:CURRent?
FETCh:CURRent?
Phase Selectable
These queries return the dc component of the output current being sourced at the output terminals.
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
42
MEASure:[SCALar]:CURRent[:DC]?
FETCh:[SCALar]:CURRent[:DC]?
None
MEAS:CURR?
FETC:CURR?
<NR3>
MEAS:VOLT? MEAS:CURR:AC?