Download Agilent Technologies 6834B User`s guide

Transcript
3 - Language Dictionary
MEASure:POWer:AC:APParent?
FETCh:POWer:AC:APParent?
Phase Selectable
These queries return the apparent power being sourced at the output terminals in volt-amperes.
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
MEASure:[SCALar]:POWer:AC:APParent?
FETCh:[SCALar]:POWer:AC:APParent?
None
MEAS:POW:AC:APP?
FETC:POW:AC:APP?
<NR3>
MEAS:POW:REAC? MEAS:POW:PFAC?
MEASure:POWer:AC:REACtive?
FETCh:POWer:AC:REACtive?
Phase Selectable
These queries return the reactive power being sourced at the output terminals in volt-amperes reactive.
Reactive power is computed as:
VAR = sqrt(square(apparent power) square(real power))
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
MEASure:[SCALar]:POWer:AC:REACtive?
FETCh:[SCALar]:POWer:AC:REACtive?
None
MEAS:POW:AC:REAC?
FETC:POW:AC:REAC?
<NR3>
MEAS:POW:AC:APP? MEAS:POW:PFAC?
MEASure:POWer:AC:PFACtor?
FETCh:POWer:AC:PFACtor?
Phase Selectable
These queries return the output power factor. The power factor is computed as:
pfactor = real power/apparent power
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
50
MEASure:[SCALar]:POWer:AC:PFACtor?
FETCh:[SCALar]:POWer:AC:PFACtor?
None
MEAS:POW:AC:PFAC?
FETC:POW:AC:PFAC?
<NR3>
MEAS:POW:AC:APP? MEAS:POW:REAC?