Download iANT100 Manual

Transcript
Operating Manual
iANT100, iANT101
Operating Manual
This page is intentionally left blank.
Document Number 314666 (See Last Page for Revision Details)
©2013 Extronics Limited. This document is Copyright Extronics limited.
Extronics reserve the right to change this manual and its contents without notice, the latest
version applies.
2
Operating Manual
Contents
1
Introduction.......................................................................................................... 4
1.1 Antenna Profile .............................................................................................. 4
2 Safety Information and Notes .............................................................................. 5
2.1 Storage of this Manual................................................................................... 5
2.2 Special Conditions for Safe Use .................................................................... 5
2.2.1 ATEX/IECEx ........................................................................................... 5
2.3 List of Notes .................................................................................................. 5
3 General information ............................................................................................. 7
3.1 Installation and Function................................................................................ 7
3.1.1 Parts Enclosed ........................................................................................ 7
3.1.2 Antenna Installation Recommendations .................................................. 7
3.2 Optional Accessories ..................................................................................... 8
3.2.1 iANTMB01............................................................................................... 8
3.2.2 iANTMB02............................................................................................... 9
3.2.3 iANTMB03............................................................................................... 9
3.2.4 iANTMB04............................................................................................. 10
3.2.5 iANTMB05............................................................................................. 10
3.2.6 iANTMB06............................................................................................. 11
4 Technical Specification ...................................................................................... 12
4.1 Antenna polar patterns and VSWR Plots..................................................... 12
4.1.1 iANT100/101 2.4 GHz/5 GHz ................................................................ 12
4.1.2 iANT100 GSM Quad Band .................................................................... 13
4.1.3 iANT101 437/458.5/466MHz ................................................................. 14
4.2 iANT100 Specifications .............................................................................. 15
4.3 iANT100 Cable Loss.................................................................................... 16
4.4 iANT101 Specifications ............................................................................... 16
4.5 iANT101 Cable Loss.................................................................................... 17
5 Intended Purpose Usage ................................................................................... 18
5.1 Transportation and Storage ......................................................................... 18
5.2 Cleaning and Maintenance .......................................................................... 18
6 Fitting of Exd Antenna Cable Gland on iANT100 .............................................. 19
7 Type Codes ....................................................................................................... 23
7.1 iANT100 ...................................................................................................... 23
7.2 iANT101 ...................................................................................................... 24
8 EC Declaration of Conformity ............................................................................ 25
9 ATEX & IECEx CERTIFICATION ...................................................................... 26
10
Warranty Information ...................................................................................... 33
11
Manual Revision ............................................................................................. 34
3
Operating Manual
1 Introduction
1.1 Antenna Profile
The iANT100 and iANT101 are increased safety antennas and have been
designed and approved by ATEX and IECEx for use in Zone 1 / 21 & Zone 2/22
Hazardous Area Environments.
The iANT100 and iANT101 are optimised for use in WLAN installations in the 2.4GHz
and 5 GHz spectrums for IEEE802.11 a/b/g wireless networks or 2.4GHz and 5GHz
wireless MESH Ethernet networks.
These devices can be used with explosion proof Access Points such as the Extronics
iWAP101 iWAP103 or an Access Point installed in a safe area and just the antenna
installed in the hazardous area.
The units are explosion protected in accordance with IEC 60079-0:2007-10 edition 5,
IEC 60079-31:2008 edition 1, IEC60079-7:2006-07 edition 4, EN 60079-0:2009, EN
60079-7:2007.
The device is certified as:
II 2 GD
Ex e IIC T6 Gb (Ta = -40°C to 60°C)
Ex t IIIC T85°C Db IP66.
It can operate in areas classified as Zone 1, gas and dust with a temperature class of
T6 with a maximum temperature of 60oC
The minimum permissible ambient temperature is -40oC
The maximum permissible ambient temperature is 60oC
4
Operating Manual
2 Safety Information and Notes
2.1 Storage of this Manual
Keep this user manual safe and in the vicinity of the antenna. All persons who have to work
on or with the controller should be advised on where the manual is stored.
2.2 Special Conditions for Safe Use
2.2.1
ATEX/IECEx
• If terminated in the hazardous area, the flying lead shall be installed in an
appropriately-certified enclosure. An example would be termination inside a
flameproof enclosure via a suitable certified flameproof gland.
• The threshold power of the antenna shall be limited to 2 (two) watts when the
antenna gain is taken into account. Programmable or software control
intended for setting by the user is not permitted.
2.3 List of Notes
The notes supplied in this chapter provide information on the following.
• Danger / Warning.
o Possible hazard to life or health.
• Caution
o Possible damage to property.
• Important
o Possible damage to the device, or associated equipment.
• Information
o
Notes on the optimum use of the device
Warning!
The iANT100/iANT101 enclosure is an electrostatic charging hazard;
clean only with a damp cloth
Important
The iANT100/iANT101 may be used in zones 1 and 2 with flammable
gases and vapours with apparatus groups IIA, IIB & IIC and with all
temperature classes.
Important
The iANT100/iANT101 may also be used in zones 21 and 22 with all
flammable dusts compatible with the maximum surface temperature of
60°°C. The appropriate safety margin should be applied
Important
The iANT100/iANT101 is only certified for use in ambient temperatures in
the range -40oC to +60oC and should not be used outside this range
5
Operating Manual
Important
The equipment has not been assessed as a safety-related device (as
referred to by Directive 94/9/EC Annex II, clause 1.5
Important
Installation of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice (EN 6007914).
Important
If terminated in the hazardous area, the flying lead shall be installed in an
appropriately-certified enclosure. An example would be termination
inside a flameproof enclosure via a suitable certified flameproof gland.
Important
The iANT100/iANT101 and associated wiring should be periodically
inspected for damage, in accordance with the applicable code of practice
(EN 60079-17)
Important
Repair of the iANT shall only be carried out by the manufacturer:
The antenna contains no user-serviceable parts
Warning
The maximum radiated power shall not exceed 2 W EIRP
6
Operating Manual
3 General information
3.1 Installation and Function
3.1.1
Parts Enclosed
iANT100
•
•
•
•
•
•
•
•
1 x Antenna with 1mtr / 5mtr cable
1 x M6 x 10 slotted machine screw
1 x M6 lock washer
1 x Antenna Bracket
2 x 1 ¼” x 8 Wood Screws
2 x 6mm red rawl plugs
2 x self adhesive nylon blocks
2 x cable ties
iANT101
•
•
1 x Antenna with Cable as Ordered
1 x Antenna Pipe Mounting Bracket
If any Part is damaged or missing, contact Extronics Ltd
Warning
3.1.2
Ensure that the M6 screw used to affix the iANT100 antenna does not
protrude more than 10mm into the antenna through the attachment
bracket. Protrusion greater than 10mm will cause damage to the
antenna.
Antenna Installation Recommendations
It is recommended that the antennas be mounted at least 204mm (8") away from any
metal objects e.g. metal clad walls or girders.
The antennas should be mounted at least 600mm (24") apart for optimal
performance, but will perform well closer together.
Information
The iANT100 has optional brackets which allow the antenna to be
mounted directly to Extronics Range of hazardous area access points
Information
The iANT101 is supplied with a pipe mounting bracket
Information It is impossible for the straight or right-angled N-type connector fitted to
the iANT100 to pass through an M20 gland entry. Either a larger entry
(for example an M25) should be used, or the connector should be fitted
after gland installation. Select either the gland reducer option or the
connector supplied separately option for the iANT100 as appropriate.
Information It is impossible for the straight N-type connector fitted to the iANT101 to
pass through an M20 gland entry. Either a larger entry (for example an
M25) should be used, or the connector should be fitted after gland
installation. Select either the gland reducer option or the connector
supplied separately option for the iANT101 as appropriate.
7
Operating Manual
Information It is impossible for the right-angled N-type connector fitted to the
iANT101 to pass through an M25 gland entry. Either a larger entry (for
example an M30) should be used, or the connector should be fitted after
gland installation. Select either the connector supplied separately option
for the iANT101, or use a larger entry as appropriate.
3.2 Optional Accessories
3.2.1
iANTMB01
316L stainless steel wall mount bracket assembly for iANT101 antenna.
This bracket is fitted away from the iWAP enclosure.
8
Operating Manual
3.2.2
iANTMB02
316L stainless steel bracket kit, 365mm length, for two iANT100 antennas.
This bracket can be fitted onto or away from the iWAP enclosure.
3.2.3
iANTMB03
316L stainless steel wall mount bracket kit for iANT100 antenna.
This bracket is fitted away from the iWAP enclosure.
9
Operating Manual
3.2.4
iANTMB04
316L stainless steel ceiling mount bracket kit for iANT100 antenna.
This bracket is fitted away from the iWAP enclosure.
3.2.5
iANTMB05
316L stainless steel bracket kit, 365mm length, for three iANT100 antennas.
This bracket can be fitted onto or away from the iWAP enclosure.
10
Operating Manual
3.2.6
iANTMB06
316L stainless steel bracket kit, 430mm length, for three iANT100 antennas.
This bracket can be fitted onto or away from the iWAP enclosure.
11
Operating Manual
4 Technical Specification
4.1 Antenna polar patterns and VSWR Plots
4.1.1
iANT100/101 2.4 GHz/5 GHz
iANT100/101 2.4GHz E Plane Pattern Vertical Free
Space 3dB Beam-Width Approx 34°°
iANT100/101 2.4 GHz H-Plane Pattern Vertical Free
Space Omni-Directional
iANT100/101 5 GHz E Plane Pattern Vertical Free Space
3dB Beam-Width Approx 16°°
iANT100/101 5 GHz H-Plane Pattern Vertical Free
Space Omni-Directional
12
Operating Manual
iANT100/101 2.4GHz VSWR Plot
<1.8:1 2350—2550 MHz
4.1.2
iANT100/101 5GHz VSWR
<2:1 5000—6000 MHz
iANT100 GSM Quad Band
iANT100 GSM Quad Band E Plane Pattern
Vertical Free Space Beam-Width Approx 80°°
iANT100 GSM Quad Band H-Plane Pattern Vertical Free
Space Omni-Directional
13
Operating Manual
iANT100 GSM Quad Band VSWR Plot
<2:1 1750-1850MHz
4.1.3
iANT100 GSM Quad Band VSWR Plot
<2:1 860- 940 MHz
iANT101 437/458.5/466MHz
iANT101 437/458.5/466MHz
E Plane Pattern
Vertical Free Space Beam-Width Approx 80°°
iANT101 437/458.5/466MHz
H-Plane Pattern Vertical Free Space
Omni-Directional
14
Operating Manual
4.2
iANT100 Specifications
Parameter
iANT100-24
iANT100-58
iANT100-GSM-QB
Power
Max power 1 Watt continuous
Max power 1 Watt continuous
Max power 1 Watt continuous
ATEX: Maximum threshold power
must not exceed 2W EIRP when
taking antenna gain into account.
Software RF Power control settable by
the user is not permitted
ATEX: Maximum threshold power
must not exceed 2W EIRP when
taking antenna gain into account.
Software RF Power control settable by
the user is not permitted
ATEX: Maximum threshold power must
not exceed 2W EIRP when taking
antenna gain into account. Software RF
Power control settable by the user is
not permitted
Dimensions
210mm Length, 38mm Diameter
210mm Length, 38mm Diameter
210mm Length, 38mm Diameter
Weight
365g
365g
365g
Connections
Straight Reverse Polarity BNC
(Other connector types available on
request)
Straight Reverse Polarity BNC
(Other connector types available on
request)
Straight Reverse Polarity SMA
(Other connector types available on
request)
Cable Sealed Supplied as 5 metre as standard,
Lead Length other lengths on request
Supplied as 5 metre as standard,
other lengths on request
Supplied as 5 metre as standard, other
lengths on request
Frequency
2300 – 2500MHz
5150—5875MHz
GSM 850 / 900 / 1800 / 1900 / 2100
Bandwidth
+/- 100MHz
Bands A, B and C
Impedance
50 Ohms
50 Ohms
50 Ohms
Return Loss
Better than –12 dB over bandwidth
Better than –12 dB over bandwidth
Better than -12dB over bandwidth
Gain
5 dBi
8 dBi
2 dBi
Horizontal
Radiation
Pattern
Omni Directional
Omni Directional
Omni Directional
Vertical 3dB
Beam-width
Approx 34o
Approx 16o
Approx 80o
Radiating
Element
Brass tubing, copper plated steel rod
PCB and Brass tubing.
PCB
Ambient
-40°C to 60°C
Temperature
-40°C to 60°C
-40°C to +60°C
IP Rating
IP66
IP66
IP66
Certification
Number
Sira 11ATEX3100X
IECEx SIR 11.0045X
Sira 11ATEX3100X
IECEx SIR 11.0045X
Sira 11ATEX3100X
IECEx SIR 11.0045X
ATEX
Certification
II 2GD Ex e IIC T6 Gb (Ta = -40°C to
+60°C)
Ex t IIIC T85°C Db IP66
II 2GD Ex e IIC T6 Gb (Ta = -40°C to
+60°C)
Ex t IIIC T85°C Db IP66
II 2GD Ex e IIC T6 Gb (Ta = -40°C to
+60°C)
Ex t IIIC T85°C Db IP66
IECEx
Certification
Ex e IIC T6 Gb (Ta = -40°C to
+60°C)Ex t IIIC T85°C Db IP66
Ex e IIC T6 Gb (Ta = -40°C to
+60°C)Ex t IIIC T85°C Db IP66
Ex e IIC T6 Gb (Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
15
Operating Manual
4.3 iANT100 Cable Loss
Cable length
1m
3m
5m
8m
10m
900MHz
0.36dB
1.07dB
1.78dB
2.84dB
3.55dB
1800MHz
0.53dB
1.58dB
2.63dB
4.20dB
5.25dB
2GHz
0.55dB
1.66dB
2.77dB
4.43dB
5.54dB
2.5GHz
0.62dB
1.87dB
3.12dB
4.99dB
6.24dB
5GHz
0.91dB
2.72dB
4.53dB
7.24dB
9.10dB
5.8GHz
0.98dB
2.94dB
4.91dB
7.85dB
9.81dB
4.4 iANT101 Specifications
iANT101 2.4GHz
Power
iANT101 5GHz
iANT101 437/458.5/466MHz
Max power 1 Watt continuous
Max power 1 Watt continuous
Max power 1 Watt continuous
ATEX: Maximum threshold
power must not exceed 2W EIRP
when taking antenna gain into
account. Software RF Power
control settable by the user is
not permitted
ATEX: Maximum threshold power
must not exceed 2W EIRP when
taking antenna gain into account.
Software RF Power control settable
by the user is not permitted
ATEX: Maximum threshold power must
not exceed 2W EIRP when taking
antenna gain into account. Software RF
Power control settable by the user is
not permitted
Dimensions
250mm Length, 38mm Diameter 250mm Length, 38mm Diameter
330mm Length, 38mm Diameter
Weight
480g Not including Cable
480g Not including Cable
510g Not including Cable
Connections
Please Specify with Order
Please Specify with Order
Please Specify with Order
Frequency
2300 - 2500MHz
5150 - 5875MHz
437/458.5 MHz/466MHz
Bandwidth
+/- 100MHz
Suitable for Bands A, B and C
+/- 3MHz
Impedance
50 Ohms
50 Ohms
50 Ohms
Return Loss
Better than –12 dB over
bandwidth
Better than –12 dB over bandwidth
Better than –14 dB over bandwidth
Gain
5 dBi @ 2.4 GHz
8 dBi @ 5.8 GHz
0dBi @ 437/458.5/466MHz
Horizontal
Radiation Pattern
Omni-directional
Omni-directional
Omni-directional
Vertical 3dB
Beam-width
Approx 34o
Approx 16o
Approx 80o
Radiator Element
Brass tubing, copper plated steel PCB and Brass Rod
rod
Brass Tubing & Helical Element
Ambient
Temperature
-40°C to 60°C
-40°C to 60°C
-40°C to 60°C
IP Rating
IP66
IP66
IP66
Certification
Number
Sira 11ATEX3100X
IECEx SIR 11.0045X
Sira 11ATEX3100X
IECEx SIR 11.0045X
Sira 11ATEX3100X
IECEx SIR 11.0045X
ATEX Certification
II 2GD Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
II 2GD Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
II 2GD Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
16
Operating Manual
IECEx
Certification
Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
Cable Type
LMR-400-FR
Non-halogen to IEC60754
Low smoke to IEC61034
Flame-retardant to
IEC332-1 + 3
LMR-400-FR
Non-halogen to IEC60754
Low smoke to IEC61034
Flame-retardant to
IEC332-1 + 3
LMR-400-FR
Non-halogen to IEC60754
Low smoke to IEC61034
Flame-retardant to
IEC332-1 + 3
Mounting
Antenna supplied with
galvanised steel pipe mounting
bracket for 38mm pipe.
Antenna supplied with galvanised
steel pipe mounting bracket for
38mm pipe.
Antenna supplied with galvanised steel
pipe mounting bracket for 38mm pipe.
Optional 316L stainless steel
wall mounting bracket also
available
Optional 316L stainless steel wall
mounting bracket also available
Optional 316L stainless steel wall
mounting bracket also available
4.5 iANT101 Cable Loss
Cable length
1m
2m
5m
10m
15m
20m
30m
437/458.5/466MHz
0.10dB
0.20dB
0.40dB
0.90dB
1.30dB
1.80dB
2.70dB
17
2.4GHz
0.22dB
0.44dB
1.10dB
2.20dB
3.30dB
4.40dB
6.60dB
5.8GHz
0.36dB
0.72dB
1.80dB
3.60dB
5.40dB
7.20dB
10.80dB
Operating Manual
5 Intended Purpose Usage
5.1 Transportation and Storage
All iANT devices must be so transported and stored that they are not subjected to
any excessive mechanical stresses.
5.2 Cleaning and Maintenance
The iANT and all its components require no maintenance and are self-monitoring. All
work on the iANT100 or iANT101 by personnel who are not expressly qualified for
such activities will cause the Ex approval and the guarantee to become void.
Warning!
The iANT100 and iANT101 enclosures are an electrostatic charging
hazard; clean only with a damp cloth
18
Operating Manual
6 Fitting of Exd Antenna Cable Gland on
iANT100
These instructions are intended only for when the iANT100 is to be used with the
iWAP range of enclosures For full installation instructions also refer to Peppers CRUB assembly instructions . Contact Extronics for fitting instructions for iANT101
glands.
Figure 1
Figure 2
Figure 3
Figure 4
19
Operating Manual
Figure 5
Figure 6
Figure 7
20
Operating Manual
Figure 8
Figure 9
21
Operating Manual
1. Split gland as Shown in Figure 1
2. Fit Entry Body into the iWAP enclosure. Hand-tighten, then using wrench
tighten a further ½ turn. DO NOT EXCEED MAX TORQUE FOR
ENCLOSURE
3. Slide Rear Assembly (Back Nut, Mid Cap and Union Nut) onto cable.
CABLE PREPARATION
1. Cut around circumference of cable, being careful not to cut into braid.
2. Slide cable sheath to expose 20-25mm of braid as shown in figure 2.
3. Check compound has not passed its "Use By" date..Note Installation at
temperatures below 10°C should be avoided.
4. Trim any hardened pieces from ends of stick. Mix the compound by
rolling, folding and breaking. Ease mixing by cutting large sticks in half.
Fully mixed compound has a uniform yellow colour with no streaks.
5. Support the cable and Rear Assembly, holding them roughly concentric.
Starting at the middle, pack a small amount of compound around the
screen of the cable as shown in figure 3. Pressing and working the
compound into the braid.
6. Pack Compound around the cable to completely fill the Rear Assembly
cup. Build up compound around the outside of the cores, with a slight
taper & to approximately 40mm in length, as shown in figure 4
7. Pass the cable through and push compound into Entry Body until Rear
Assembly engages. Remove squeezed out compound as Screw Union
full turns onto Entry Body. Ensure that compound emerges at entry
thread, as per figures 7 and 8.
8. Clean off excess compound from Entry Body to allow withdrawal when
cured, as shown in figure 9.
9. Leave to cure for a minimum of 4 hours when working at 21ºC
10. To release and pull back joint for inspection, unscrew Union Nut
11. Hand-tighten Union Nut to remake joint. Then refer to table below and
tighten Union Nut using wrench to the given amount. Hold Mid Cap with
wrench and tighten Back Nut onto cable. Ensure seal makes full contact
with cable sheath, then tighten 1 extra turn
12. The equipment should not be energised until the compound has been
left to cure for at least 4 hours when working at 21ºC. See chart
‘Energising Time vs. Temperature’ for further guidance
HEALTH AND SAFETY WARNING
The resin used in the compound can cause eye and skin irritation. For your personal
protection, wear the gloves supplied while mixing and applying. The uncured
compound should not be allowed to come into contact with foodstuffs.
A COMPREHENSIVE SAFETY DATA SHEET PROVIDED BY THE COMPOUND
MANUFACTURER IS AVAILABLE ON REQUEST
22
Operating Manual
7 Type Codes
7.1 iANT100
iANT100 Zone 1 Omni Directional Antenna
iANT100-[#1]-[#2]-[#3]-[#4]-[#5]-[#6]-[#7]-[#8]
Specify option [#1] - Frequency
2.4GHz Frequency
5 GHz Frequency
GSM Quad-band
24
58
QB
Specify option [#2] - Cable Length
5m
Special cable length
5
S
Specify option [#3] - Connector type
Straight N-type male *
Right angle N-type male (Recommended for use with Extronics iWAP103) *
Straight reverse-polarity SMA male
Right-angle reverse-polarity TNC male
Straight reverse-polarity BNC male
No connector fitted
1
2
3
4
5
6
* N.B. It is impossible for a straight or right-angled N-type connector fitted to the cable to pass through the enclosure entry for an M20
cable gland. Either the connector must be fitted after passing the cable through the enclosure hole, or a larger M25 enclosure
entry should be used with a suitable thread reducer. This permits the N-type connector to pass through the hole.
Select either option #4 (N) or option#7 (2).
Note that the Extronics iWAP103 is supplied with M25 cable entries and M25-M20 thread reducers as standard.
Specify option [#4] - Connector fitting
Selected connector fitted
Crimp connector supplied separately for customer fitting (RG58 crimp tool required)
F
N
Specify option [#5] - Cable Gland
No gland fitted
Fitted with CR-UB-NP-16-M20 Ex d cable gland
Fitted with CR-UB-NP-16-075-NPT Ex d cable gland
Fitted with customer-supplied cable gland
1
2
3
4
Specify option [#6] - Cable Gland Position
Cable gland installed at default distance from antenna (cable length minus 0.45m)
Special cable gland position, specify on order
D
S
(Cable gland must be a minimum of 0.65m from the antenna, and a minimum
of 0.45m is recommended between the gland and connector)
Specify option [#7] - Gland thread reducer supplied
No thread reducer supplied
CR-UB-NP-16-M20 Ex d cable gland supplied with M25 - M20 thread reducer
1
2
Specify option [#8] - Mounting bracket
Supplied with standard aluminium wall mounting bracket
Supplied with 316 stainless steel wall mounting bracket
1
2
Optional Accessories also available separately
316 stainless steel wall mounting bracket
iANTMB03
23
Operating Manual
7.2 iANT101
iANT101 Zone 1 Omni Directional Antenna
iANT101-[#1]-[#2]-[#3]-[#4]-[#5]-[#6] [#7]-[#8]
Specify option [#1] – Frequency
2.4GHz
5 GHz
437MHz
458.5MHz
466MHz
24
58
43
45
46
Specify option [#2] - Cable Length
5m
10m
15m
20m
25m
Special cable length
5
10
15
20
25
S
Specify option [#3] - Connector type
Straight N-type male
*
Right Angle N-type male (recommended for use with Extronics iWAP103) **
Straight reverse-polarity SMA male
Straight reverse-polarity TNC male
No connector fitted
1
2
3
4
5
* N.B. It is impossible for a straight N-type connector fitted to the cable to pass through the enclosure entry for an M20
cable gland. Either the connector must be fitted after passing the cable through the enclosure hole, or a larger M25 enclosure
entry should be used with a suitable thread reducer. This permits the N-type connector to pass through the hole.
Select either option #4 (N) or option#7 (2).
Note that the Extronics iWAP103 is supplied with M25 cable entries and M25-M20 thread reducers as standard.
**N.B. It is impossible for a right-angle N-type connector fitted to the cable to pass through the enclosure entry for an M20
or M25 cable gland. The connector must be fitted after passing the cable through the enclosure hole, or a larger entry used.
Specify option [#4] - Connector fitting
Selected connector fitted
Selected connector supplied separately for customer fitting (LMR-400 Crimp tool required)
F
N
Specify option [#5] - Cable Gland
No gland fitted
Fitted with CR-UB-NP-20-M20 Ex d cable gland
Fitted with customer-supplied cable gland
1
2
3
Specify option [#6] - Cable Gland Position
Cable gland installed at default distance from antenna (cable length minus 0.45m)
Special cable gland position, specify on order
D
S
(Cable gland must be a minimum of 0.65m from the antenna, and a minimum
of 0.45m is recommended between the gland and connector)
Specify option [#7] - Gland thread reducer supplied
No thread reducer supplied
CR-UB-NP-16-M20 Ex d cable gland supplied with M25 - M20 thread reducer
1
2
Specify option [#8] - Mounting bracket
Supplied with galvanised steel 38mm pipe mounting bracket
Supplied with 316L stainless wall mounting bracket
1
2
Optional Accessories also available separately
316L stainless steel wall mounting bracket
iANTMB01
24
Operating Manual
8 EC Declaration of Conformity
25
Operating Manual
9 ATEX & IECEx CERTIFICATION
26
Operating Manual
27
Operating Manual
28
Operating Manual
29
Operating Manual
30
Operating Manual
31
Operating Manual
32
Operating Manual
10 Warranty Information
The Customer shall carry out a thorough inspection of the delivered project or
equipment with 21 days of delivery and shall give immediate written notification to the
Company of any omissions, defects or faults.
The Company warrants that the project or equipment delivered shall accord with the
Quotation or Pricing Schedule and related Company specifications, but it does not
warrant its fitness for any other purpose.
Extronics will make good, by repair or at Extronics option by the supply of a
replacement, defects which, under proper use in accordance with specifications and
manufacturer’s instructions, appear in the goods within a period of twelve calendar
months after the goods have been delivered and arise solely from faulty design,
materials or workmanship, provided always that defective parts have been returned
to Extronics if Extronics shall have so required.
The warranty of any goods is based upon a return to Extronics factory (Return to
Base Warranty) which will be at the Customers cost. The repaired or new parts will
be delivered by Extronics carriage paid. If you allege that goods are totally unfit for
their purpose they must be returned within 7 days of receipt. Site Warranty is
expressly excluded from these terms and conditions unless agreement is made in
writing between the parties it.
Extronics liability under this clause shall be in lieu of any warranty or condition
implied by law as to the quality or fitness for any particular purpose of the goods, and
save as provided in this clause Extronics shall not be under any liability, whether in
contract, or otherwise, in respect of defects in goods delivered or for any injury other
(than personal injury caused by Extronics negligence as defined in Section 1 of the
Unfair Contract Terms Act, 1977), damage or loss resulting from such defects or from
any work done in connection therewith, provided however that nothing in this clause
shall operate to exclude any warranty or condition implied by law as to the quality of
the goods in the event that the goods when sold by you or when sold by any person
or persons to whom you may sell the goods shall become the subject of a consumer
sale as defined in the Supply of Goods (Implied Terms) Act, 1973 except that any
claim under such warranty or condition shall have arisen from any act or omission by
you or by any person or persons selling the goods by way of a consumer sale.
33
Operating Manual
11 Manual Revision
Revision
1
2
3
4
5
6
7
Description
Original Copy
Added Gland Details
Added iANT101 Version
Added Mounting Bracket Section
New ATEX & IECEx Certificates
Address change, warranty information
Additional optional mounting brackets added
34
Date
24/08/2006
25/05/2007
22/08/2008
10/12/2008
03/05/2011
08/10/2012
05/06/2013
By
David Revell
Nick Saunders
Nick Saunders
James Eastwood
Nick Saunders
Ben Seaby
Nick Eardley