Download iANT100 Manual
Transcript
Operating Manual iANT100, iANT101 Operating Manual This page is intentionally left blank. Document Number 314666 (See Last Page for Revision Details) ©2013 Extronics Limited. This document is Copyright Extronics limited. Extronics reserve the right to change this manual and its contents without notice, the latest version applies. 2 Operating Manual Contents 1 Introduction.......................................................................................................... 4 1.1 Antenna Profile .............................................................................................. 4 2 Safety Information and Notes .............................................................................. 5 2.1 Storage of this Manual................................................................................... 5 2.2 Special Conditions for Safe Use .................................................................... 5 2.2.1 ATEX/IECEx ........................................................................................... 5 2.3 List of Notes .................................................................................................. 5 3 General information ............................................................................................. 7 3.1 Installation and Function................................................................................ 7 3.1.1 Parts Enclosed ........................................................................................ 7 3.1.2 Antenna Installation Recommendations .................................................. 7 3.2 Optional Accessories ..................................................................................... 8 3.2.1 iANTMB01............................................................................................... 8 3.2.2 iANTMB02............................................................................................... 9 3.2.3 iANTMB03............................................................................................... 9 3.2.4 iANTMB04............................................................................................. 10 3.2.5 iANTMB05............................................................................................. 10 3.2.6 iANTMB06............................................................................................. 11 4 Technical Specification ...................................................................................... 12 4.1 Antenna polar patterns and VSWR Plots..................................................... 12 4.1.1 iANT100/101 2.4 GHz/5 GHz ................................................................ 12 4.1.2 iANT100 GSM Quad Band .................................................................... 13 4.1.3 iANT101 437/458.5/466MHz ................................................................. 14 4.2 iANT100 Specifications .............................................................................. 15 4.3 iANT100 Cable Loss.................................................................................... 16 4.4 iANT101 Specifications ............................................................................... 16 4.5 iANT101 Cable Loss.................................................................................... 17 5 Intended Purpose Usage ................................................................................... 18 5.1 Transportation and Storage ......................................................................... 18 5.2 Cleaning and Maintenance .......................................................................... 18 6 Fitting of Exd Antenna Cable Gland on iANT100 .............................................. 19 7 Type Codes ....................................................................................................... 23 7.1 iANT100 ...................................................................................................... 23 7.2 iANT101 ...................................................................................................... 24 8 EC Declaration of Conformity ............................................................................ 25 9 ATEX & IECEx CERTIFICATION ...................................................................... 26 10 Warranty Information ...................................................................................... 33 11 Manual Revision ............................................................................................. 34 3 Operating Manual 1 Introduction 1.1 Antenna Profile The iANT100 and iANT101 are increased safety antennas and have been designed and approved by ATEX and IECEx for use in Zone 1 / 21 & Zone 2/22 Hazardous Area Environments. The iANT100 and iANT101 are optimised for use in WLAN installations in the 2.4GHz and 5 GHz spectrums for IEEE802.11 a/b/g wireless networks or 2.4GHz and 5GHz wireless MESH Ethernet networks. These devices can be used with explosion proof Access Points such as the Extronics iWAP101 iWAP103 or an Access Point installed in a safe area and just the antenna installed in the hazardous area. The units are explosion protected in accordance with IEC 60079-0:2007-10 edition 5, IEC 60079-31:2008 edition 1, IEC60079-7:2006-07 edition 4, EN 60079-0:2009, EN 60079-7:2007. The device is certified as: II 2 GD Ex e IIC T6 Gb (Ta = -40°C to 60°C) Ex t IIIC T85°C Db IP66. It can operate in areas classified as Zone 1, gas and dust with a temperature class of T6 with a maximum temperature of 60oC The minimum permissible ambient temperature is -40oC The maximum permissible ambient temperature is 60oC 4 Operating Manual 2 Safety Information and Notes 2.1 Storage of this Manual Keep this user manual safe and in the vicinity of the antenna. All persons who have to work on or with the controller should be advised on where the manual is stored. 2.2 Special Conditions for Safe Use 2.2.1 ATEX/IECEx • If terminated in the hazardous area, the flying lead shall be installed in an appropriately-certified enclosure. An example would be termination inside a flameproof enclosure via a suitable certified flameproof gland. • The threshold power of the antenna shall be limited to 2 (two) watts when the antenna gain is taken into account. Programmable or software control intended for setting by the user is not permitted. 2.3 List of Notes The notes supplied in this chapter provide information on the following. • Danger / Warning. o Possible hazard to life or health. • Caution o Possible damage to property. • Important o Possible damage to the device, or associated equipment. • Information o Notes on the optimum use of the device Warning! The iANT100/iANT101 enclosure is an electrostatic charging hazard; clean only with a damp cloth Important The iANT100/iANT101 may be used in zones 1 and 2 with flammable gases and vapours with apparatus groups IIA, IIB & IIC and with all temperature classes. Important The iANT100/iANT101 may also be used in zones 21 and 22 with all flammable dusts compatible with the maximum surface temperature of 60°°C. The appropriate safety margin should be applied Important The iANT100/iANT101 is only certified for use in ambient temperatures in the range -40oC to +60oC and should not be used outside this range 5 Operating Manual Important The equipment has not been assessed as a safety-related device (as referred to by Directive 94/9/EC Annex II, clause 1.5 Important Installation of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice (EN 6007914). Important If terminated in the hazardous area, the flying lead shall be installed in an appropriately-certified enclosure. An example would be termination inside a flameproof enclosure via a suitable certified flameproof gland. Important The iANT100/iANT101 and associated wiring should be periodically inspected for damage, in accordance with the applicable code of practice (EN 60079-17) Important Repair of the iANT shall only be carried out by the manufacturer: The antenna contains no user-serviceable parts Warning The maximum radiated power shall not exceed 2 W EIRP 6 Operating Manual 3 General information 3.1 Installation and Function 3.1.1 Parts Enclosed iANT100 • • • • • • • • 1 x Antenna with 1mtr / 5mtr cable 1 x M6 x 10 slotted machine screw 1 x M6 lock washer 1 x Antenna Bracket 2 x 1 ¼” x 8 Wood Screws 2 x 6mm red rawl plugs 2 x self adhesive nylon blocks 2 x cable ties iANT101 • • 1 x Antenna with Cable as Ordered 1 x Antenna Pipe Mounting Bracket If any Part is damaged or missing, contact Extronics Ltd Warning 3.1.2 Ensure that the M6 screw used to affix the iANT100 antenna does not protrude more than 10mm into the antenna through the attachment bracket. Protrusion greater than 10mm will cause damage to the antenna. Antenna Installation Recommendations It is recommended that the antennas be mounted at least 204mm (8") away from any metal objects e.g. metal clad walls or girders. The antennas should be mounted at least 600mm (24") apart for optimal performance, but will perform well closer together. Information The iANT100 has optional brackets which allow the antenna to be mounted directly to Extronics Range of hazardous area access points Information The iANT101 is supplied with a pipe mounting bracket Information It is impossible for the straight or right-angled N-type connector fitted to the iANT100 to pass through an M20 gland entry. Either a larger entry (for example an M25) should be used, or the connector should be fitted after gland installation. Select either the gland reducer option or the connector supplied separately option for the iANT100 as appropriate. Information It is impossible for the straight N-type connector fitted to the iANT101 to pass through an M20 gland entry. Either a larger entry (for example an M25) should be used, or the connector should be fitted after gland installation. Select either the gland reducer option or the connector supplied separately option for the iANT101 as appropriate. 7 Operating Manual Information It is impossible for the right-angled N-type connector fitted to the iANT101 to pass through an M25 gland entry. Either a larger entry (for example an M30) should be used, or the connector should be fitted after gland installation. Select either the connector supplied separately option for the iANT101, or use a larger entry as appropriate. 3.2 Optional Accessories 3.2.1 iANTMB01 316L stainless steel wall mount bracket assembly for iANT101 antenna. This bracket is fitted away from the iWAP enclosure. 8 Operating Manual 3.2.2 iANTMB02 316L stainless steel bracket kit, 365mm length, for two iANT100 antennas. This bracket can be fitted onto or away from the iWAP enclosure. 3.2.3 iANTMB03 316L stainless steel wall mount bracket kit for iANT100 antenna. This bracket is fitted away from the iWAP enclosure. 9 Operating Manual 3.2.4 iANTMB04 316L stainless steel ceiling mount bracket kit for iANT100 antenna. This bracket is fitted away from the iWAP enclosure. 3.2.5 iANTMB05 316L stainless steel bracket kit, 365mm length, for three iANT100 antennas. This bracket can be fitted onto or away from the iWAP enclosure. 10 Operating Manual 3.2.6 iANTMB06 316L stainless steel bracket kit, 430mm length, for three iANT100 antennas. This bracket can be fitted onto or away from the iWAP enclosure. 11 Operating Manual 4 Technical Specification 4.1 Antenna polar patterns and VSWR Plots 4.1.1 iANT100/101 2.4 GHz/5 GHz iANT100/101 2.4GHz E Plane Pattern Vertical Free Space 3dB Beam-Width Approx 34°° iANT100/101 2.4 GHz H-Plane Pattern Vertical Free Space Omni-Directional iANT100/101 5 GHz E Plane Pattern Vertical Free Space 3dB Beam-Width Approx 16°° iANT100/101 5 GHz H-Plane Pattern Vertical Free Space Omni-Directional 12 Operating Manual iANT100/101 2.4GHz VSWR Plot <1.8:1 2350—2550 MHz 4.1.2 iANT100/101 5GHz VSWR <2:1 5000—6000 MHz iANT100 GSM Quad Band iANT100 GSM Quad Band E Plane Pattern Vertical Free Space Beam-Width Approx 80°° iANT100 GSM Quad Band H-Plane Pattern Vertical Free Space Omni-Directional 13 Operating Manual iANT100 GSM Quad Band VSWR Plot <2:1 1750-1850MHz 4.1.3 iANT100 GSM Quad Band VSWR Plot <2:1 860- 940 MHz iANT101 437/458.5/466MHz iANT101 437/458.5/466MHz E Plane Pattern Vertical Free Space Beam-Width Approx 80°° iANT101 437/458.5/466MHz H-Plane Pattern Vertical Free Space Omni-Directional 14 Operating Manual 4.2 iANT100 Specifications Parameter iANT100-24 iANT100-58 iANT100-GSM-QB Power Max power 1 Watt continuous Max power 1 Watt continuous Max power 1 Watt continuous ATEX: Maximum threshold power must not exceed 2W EIRP when taking antenna gain into account. Software RF Power control settable by the user is not permitted ATEX: Maximum threshold power must not exceed 2W EIRP when taking antenna gain into account. Software RF Power control settable by the user is not permitted ATEX: Maximum threshold power must not exceed 2W EIRP when taking antenna gain into account. Software RF Power control settable by the user is not permitted Dimensions 210mm Length, 38mm Diameter 210mm Length, 38mm Diameter 210mm Length, 38mm Diameter Weight 365g 365g 365g Connections Straight Reverse Polarity BNC (Other connector types available on request) Straight Reverse Polarity BNC (Other connector types available on request) Straight Reverse Polarity SMA (Other connector types available on request) Cable Sealed Supplied as 5 metre as standard, Lead Length other lengths on request Supplied as 5 metre as standard, other lengths on request Supplied as 5 metre as standard, other lengths on request Frequency 2300 – 2500MHz 5150—5875MHz GSM 850 / 900 / 1800 / 1900 / 2100 Bandwidth +/- 100MHz Bands A, B and C Impedance 50 Ohms 50 Ohms 50 Ohms Return Loss Better than –12 dB over bandwidth Better than –12 dB over bandwidth Better than -12dB over bandwidth Gain 5 dBi 8 dBi 2 dBi Horizontal Radiation Pattern Omni Directional Omni Directional Omni Directional Vertical 3dB Beam-width Approx 34o Approx 16o Approx 80o Radiating Element Brass tubing, copper plated steel rod PCB and Brass tubing. PCB Ambient -40°C to 60°C Temperature -40°C to 60°C -40°C to +60°C IP Rating IP66 IP66 IP66 Certification Number Sira 11ATEX3100X IECEx SIR 11.0045X Sira 11ATEX3100X IECEx SIR 11.0045X Sira 11ATEX3100X IECEx SIR 11.0045X ATEX Certification II 2GD Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 II 2GD Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 II 2GD Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 IECEx Certification Ex e IIC T6 Gb (Ta = -40°C to +60°C)Ex t IIIC T85°C Db IP66 Ex e IIC T6 Gb (Ta = -40°C to +60°C)Ex t IIIC T85°C Db IP66 Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 15 Operating Manual 4.3 iANT100 Cable Loss Cable length 1m 3m 5m 8m 10m 900MHz 0.36dB 1.07dB 1.78dB 2.84dB 3.55dB 1800MHz 0.53dB 1.58dB 2.63dB 4.20dB 5.25dB 2GHz 0.55dB 1.66dB 2.77dB 4.43dB 5.54dB 2.5GHz 0.62dB 1.87dB 3.12dB 4.99dB 6.24dB 5GHz 0.91dB 2.72dB 4.53dB 7.24dB 9.10dB 5.8GHz 0.98dB 2.94dB 4.91dB 7.85dB 9.81dB 4.4 iANT101 Specifications iANT101 2.4GHz Power iANT101 5GHz iANT101 437/458.5/466MHz Max power 1 Watt continuous Max power 1 Watt continuous Max power 1 Watt continuous ATEX: Maximum threshold power must not exceed 2W EIRP when taking antenna gain into account. Software RF Power control settable by the user is not permitted ATEX: Maximum threshold power must not exceed 2W EIRP when taking antenna gain into account. Software RF Power control settable by the user is not permitted ATEX: Maximum threshold power must not exceed 2W EIRP when taking antenna gain into account. Software RF Power control settable by the user is not permitted Dimensions 250mm Length, 38mm Diameter 250mm Length, 38mm Diameter 330mm Length, 38mm Diameter Weight 480g Not including Cable 480g Not including Cable 510g Not including Cable Connections Please Specify with Order Please Specify with Order Please Specify with Order Frequency 2300 - 2500MHz 5150 - 5875MHz 437/458.5 MHz/466MHz Bandwidth +/- 100MHz Suitable for Bands A, B and C +/- 3MHz Impedance 50 Ohms 50 Ohms 50 Ohms Return Loss Better than –12 dB over bandwidth Better than –12 dB over bandwidth Better than –14 dB over bandwidth Gain 5 dBi @ 2.4 GHz 8 dBi @ 5.8 GHz 0dBi @ 437/458.5/466MHz Horizontal Radiation Pattern Omni-directional Omni-directional Omni-directional Vertical 3dB Beam-width Approx 34o Approx 16o Approx 80o Radiator Element Brass tubing, copper plated steel PCB and Brass Rod rod Brass Tubing & Helical Element Ambient Temperature -40°C to 60°C -40°C to 60°C -40°C to 60°C IP Rating IP66 IP66 IP66 Certification Number Sira 11ATEX3100X IECEx SIR 11.0045X Sira 11ATEX3100X IECEx SIR 11.0045X Sira 11ATEX3100X IECEx SIR 11.0045X ATEX Certification II 2GD Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 II 2GD Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 II 2GD Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 16 Operating Manual IECEx Certification Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 Ex e IIC T6 Gb (Ta = -40°C to +60°C) Ex t IIIC T85°C Db IP66 Cable Type LMR-400-FR Non-halogen to IEC60754 Low smoke to IEC61034 Flame-retardant to IEC332-1 + 3 LMR-400-FR Non-halogen to IEC60754 Low smoke to IEC61034 Flame-retardant to IEC332-1 + 3 LMR-400-FR Non-halogen to IEC60754 Low smoke to IEC61034 Flame-retardant to IEC332-1 + 3 Mounting Antenna supplied with galvanised steel pipe mounting bracket for 38mm pipe. Antenna supplied with galvanised steel pipe mounting bracket for 38mm pipe. Antenna supplied with galvanised steel pipe mounting bracket for 38mm pipe. Optional 316L stainless steel wall mounting bracket also available Optional 316L stainless steel wall mounting bracket also available Optional 316L stainless steel wall mounting bracket also available 4.5 iANT101 Cable Loss Cable length 1m 2m 5m 10m 15m 20m 30m 437/458.5/466MHz 0.10dB 0.20dB 0.40dB 0.90dB 1.30dB 1.80dB 2.70dB 17 2.4GHz 0.22dB 0.44dB 1.10dB 2.20dB 3.30dB 4.40dB 6.60dB 5.8GHz 0.36dB 0.72dB 1.80dB 3.60dB 5.40dB 7.20dB 10.80dB Operating Manual 5 Intended Purpose Usage 5.1 Transportation and Storage All iANT devices must be so transported and stored that they are not subjected to any excessive mechanical stresses. 5.2 Cleaning and Maintenance The iANT and all its components require no maintenance and are self-monitoring. All work on the iANT100 or iANT101 by personnel who are not expressly qualified for such activities will cause the Ex approval and the guarantee to become void. Warning! The iANT100 and iANT101 enclosures are an electrostatic charging hazard; clean only with a damp cloth 18 Operating Manual 6 Fitting of Exd Antenna Cable Gland on iANT100 These instructions are intended only for when the iANT100 is to be used with the iWAP range of enclosures For full installation instructions also refer to Peppers CRUB assembly instructions . Contact Extronics for fitting instructions for iANT101 glands. Figure 1 Figure 2 Figure 3 Figure 4 19 Operating Manual Figure 5 Figure 6 Figure 7 20 Operating Manual Figure 8 Figure 9 21 Operating Manual 1. Split gland as Shown in Figure 1 2. Fit Entry Body into the iWAP enclosure. Hand-tighten, then using wrench tighten a further ½ turn. DO NOT EXCEED MAX TORQUE FOR ENCLOSURE 3. Slide Rear Assembly (Back Nut, Mid Cap and Union Nut) onto cable. CABLE PREPARATION 1. Cut around circumference of cable, being careful not to cut into braid. 2. Slide cable sheath to expose 20-25mm of braid as shown in figure 2. 3. Check compound has not passed its "Use By" date..Note Installation at temperatures below 10°C should be avoided. 4. Trim any hardened pieces from ends of stick. Mix the compound by rolling, folding and breaking. Ease mixing by cutting large sticks in half. Fully mixed compound has a uniform yellow colour with no streaks. 5. Support the cable and Rear Assembly, holding them roughly concentric. Starting at the middle, pack a small amount of compound around the screen of the cable as shown in figure 3. Pressing and working the compound into the braid. 6. Pack Compound around the cable to completely fill the Rear Assembly cup. Build up compound around the outside of the cores, with a slight taper & to approximately 40mm in length, as shown in figure 4 7. Pass the cable through and push compound into Entry Body until Rear Assembly engages. Remove squeezed out compound as Screw Union full turns onto Entry Body. Ensure that compound emerges at entry thread, as per figures 7 and 8. 8. Clean off excess compound from Entry Body to allow withdrawal when cured, as shown in figure 9. 9. Leave to cure for a minimum of 4 hours when working at 21ºC 10. To release and pull back joint for inspection, unscrew Union Nut 11. Hand-tighten Union Nut to remake joint. Then refer to table below and tighten Union Nut using wrench to the given amount. Hold Mid Cap with wrench and tighten Back Nut onto cable. Ensure seal makes full contact with cable sheath, then tighten 1 extra turn 12. The equipment should not be energised until the compound has been left to cure for at least 4 hours when working at 21ºC. See chart ‘Energising Time vs. Temperature’ for further guidance HEALTH AND SAFETY WARNING The resin used in the compound can cause eye and skin irritation. For your personal protection, wear the gloves supplied while mixing and applying. The uncured compound should not be allowed to come into contact with foodstuffs. A COMPREHENSIVE SAFETY DATA SHEET PROVIDED BY THE COMPOUND MANUFACTURER IS AVAILABLE ON REQUEST 22 Operating Manual 7 Type Codes 7.1 iANT100 iANT100 Zone 1 Omni Directional Antenna iANT100-[#1]-[#2]-[#3]-[#4]-[#5]-[#6]-[#7]-[#8] Specify option [#1] - Frequency 2.4GHz Frequency 5 GHz Frequency GSM Quad-band 24 58 QB Specify option [#2] - Cable Length 5m Special cable length 5 S Specify option [#3] - Connector type Straight N-type male * Right angle N-type male (Recommended for use with Extronics iWAP103) * Straight reverse-polarity SMA male Right-angle reverse-polarity TNC male Straight reverse-polarity BNC male No connector fitted 1 2 3 4 5 6 * N.B. It is impossible for a straight or right-angled N-type connector fitted to the cable to pass through the enclosure entry for an M20 cable gland. Either the connector must be fitted after passing the cable through the enclosure hole, or a larger M25 enclosure entry should be used with a suitable thread reducer. This permits the N-type connector to pass through the hole. Select either option #4 (N) or option#7 (2). Note that the Extronics iWAP103 is supplied with M25 cable entries and M25-M20 thread reducers as standard. Specify option [#4] - Connector fitting Selected connector fitted Crimp connector supplied separately for customer fitting (RG58 crimp tool required) F N Specify option [#5] - Cable Gland No gland fitted Fitted with CR-UB-NP-16-M20 Ex d cable gland Fitted with CR-UB-NP-16-075-NPT Ex d cable gland Fitted with customer-supplied cable gland 1 2 3 4 Specify option [#6] - Cable Gland Position Cable gland installed at default distance from antenna (cable length minus 0.45m) Special cable gland position, specify on order D S (Cable gland must be a minimum of 0.65m from the antenna, and a minimum of 0.45m is recommended between the gland and connector) Specify option [#7] - Gland thread reducer supplied No thread reducer supplied CR-UB-NP-16-M20 Ex d cable gland supplied with M25 - M20 thread reducer 1 2 Specify option [#8] - Mounting bracket Supplied with standard aluminium wall mounting bracket Supplied with 316 stainless steel wall mounting bracket 1 2 Optional Accessories also available separately 316 stainless steel wall mounting bracket iANTMB03 23 Operating Manual 7.2 iANT101 iANT101 Zone 1 Omni Directional Antenna iANT101-[#1]-[#2]-[#3]-[#4]-[#5]-[#6] [#7]-[#8] Specify option [#1] – Frequency 2.4GHz 5 GHz 437MHz 458.5MHz 466MHz 24 58 43 45 46 Specify option [#2] - Cable Length 5m 10m 15m 20m 25m Special cable length 5 10 15 20 25 S Specify option [#3] - Connector type Straight N-type male * Right Angle N-type male (recommended for use with Extronics iWAP103) ** Straight reverse-polarity SMA male Straight reverse-polarity TNC male No connector fitted 1 2 3 4 5 * N.B. It is impossible for a straight N-type connector fitted to the cable to pass through the enclosure entry for an M20 cable gland. Either the connector must be fitted after passing the cable through the enclosure hole, or a larger M25 enclosure entry should be used with a suitable thread reducer. This permits the N-type connector to pass through the hole. Select either option #4 (N) or option#7 (2). Note that the Extronics iWAP103 is supplied with M25 cable entries and M25-M20 thread reducers as standard. **N.B. It is impossible for a right-angle N-type connector fitted to the cable to pass through the enclosure entry for an M20 or M25 cable gland. The connector must be fitted after passing the cable through the enclosure hole, or a larger entry used. Specify option [#4] - Connector fitting Selected connector fitted Selected connector supplied separately for customer fitting (LMR-400 Crimp tool required) F N Specify option [#5] - Cable Gland No gland fitted Fitted with CR-UB-NP-20-M20 Ex d cable gland Fitted with customer-supplied cable gland 1 2 3 Specify option [#6] - Cable Gland Position Cable gland installed at default distance from antenna (cable length minus 0.45m) Special cable gland position, specify on order D S (Cable gland must be a minimum of 0.65m from the antenna, and a minimum of 0.45m is recommended between the gland and connector) Specify option [#7] - Gland thread reducer supplied No thread reducer supplied CR-UB-NP-16-M20 Ex d cable gland supplied with M25 - M20 thread reducer 1 2 Specify option [#8] - Mounting bracket Supplied with galvanised steel 38mm pipe mounting bracket Supplied with 316L stainless wall mounting bracket 1 2 Optional Accessories also available separately 316L stainless steel wall mounting bracket iANTMB01 24 Operating Manual 8 EC Declaration of Conformity 25 Operating Manual 9 ATEX & IECEx CERTIFICATION 26 Operating Manual 27 Operating Manual 28 Operating Manual 29 Operating Manual 30 Operating Manual 31 Operating Manual 32 Operating Manual 10 Warranty Information The Customer shall carry out a thorough inspection of the delivered project or equipment with 21 days of delivery and shall give immediate written notification to the Company of any omissions, defects or faults. The Company warrants that the project or equipment delivered shall accord with the Quotation or Pricing Schedule and related Company specifications, but it does not warrant its fitness for any other purpose. Extronics will make good, by repair or at Extronics option by the supply of a replacement, defects which, under proper use in accordance with specifications and manufacturer’s instructions, appear in the goods within a period of twelve calendar months after the goods have been delivered and arise solely from faulty design, materials or workmanship, provided always that defective parts have been returned to Extronics if Extronics shall have so required. The warranty of any goods is based upon a return to Extronics factory (Return to Base Warranty) which will be at the Customers cost. The repaired or new parts will be delivered by Extronics carriage paid. If you allege that goods are totally unfit for their purpose they must be returned within 7 days of receipt. Site Warranty is expressly excluded from these terms and conditions unless agreement is made in writing between the parties it. Extronics liability under this clause shall be in lieu of any warranty or condition implied by law as to the quality or fitness for any particular purpose of the goods, and save as provided in this clause Extronics shall not be under any liability, whether in contract, or otherwise, in respect of defects in goods delivered or for any injury other (than personal injury caused by Extronics negligence as defined in Section 1 of the Unfair Contract Terms Act, 1977), damage or loss resulting from such defects or from any work done in connection therewith, provided however that nothing in this clause shall operate to exclude any warranty or condition implied by law as to the quality of the goods in the event that the goods when sold by you or when sold by any person or persons to whom you may sell the goods shall become the subject of a consumer sale as defined in the Supply of Goods (Implied Terms) Act, 1973 except that any claim under such warranty or condition shall have arisen from any act or omission by you or by any person or persons selling the goods by way of a consumer sale. 33 Operating Manual 11 Manual Revision Revision 1 2 3 4 5 6 7 Description Original Copy Added Gland Details Added iANT101 Version Added Mounting Bracket Section New ATEX & IECEx Certificates Address change, warranty information Additional optional mounting brackets added 34 Date 24/08/2006 25/05/2007 22/08/2008 10/12/2008 03/05/2011 08/10/2012 05/06/2013 By David Revell Nick Saunders Nick Saunders James Eastwood Nick Saunders Ben Seaby Nick Eardley