INSTALLATION INSTRUCTIONS
CB12
CONNECTING BLOCK
• Output: 1 - Emitter "OUT" port (3.5mm mono mini jack).
• Model 282, 283, 284 & 286 Xantech series Mini Emitters
V G S
1 - Three terminal "VGS" block for wired
connection of Xantech IR Receivers and
SmartPad keypads.
PWR OUT
FEATURES AND SPECIFICATIONS
• Inputs: 1 - "IR RCVR" 3.5mm stereo mini jack. Accepts
any Xantech IR Receiver equipped with a
3.5mm stereo mini plug, such as the 291
series or 490-30.
IR
RCVR
Fig. 1 Model CB12 Connecting Block
may be used.
• 2.1mm coaxial power jack for Xantech 781RG or 782-00 Power Supplies.
• Dimensions: 2-1/8" x 1-1/4" x 3/4"
CAUTION: Plug only Xantech IR Receivers equipped with a stereo mini plug into the IR RCVR jack.
Do not plug emitters or other devices into this jack; to do so may damage emitters and power
supplies!
GND
+12V
+12 VDC
Smart Pad™
IR OUT
+12V
IR OUT
ROOM 3
780-10
®
J-BOX RECEIVER
INSTALLATION
291
IR Receiver
Fig. 2 illustrates a typical inHand Held
stallation using the CB12 in a
Remote
multiroom IR repeater sysROOM 2
tem. In this case a Xantech
780-10
J-Box
781RG
IR Receiver
Satellite Receiver
291 Hidden Link™ IR Re7-Foot
3Power Supply
Conductor
Cable with
ceiver is used to control a
Quick Connect
Mini Plug
Satellite Receiver and a VCR
To 120 V AC
VCR
in a cabinet behind closed
(unswitched)
doors in Room 1. Control of
the same equipment is acModel 286M
Dual Blink IR
complished from two other
Mouse Emitter
rooms with a Xantech 780-10
IR
RCVR
J-box IR Receiver and a
Equipment
CB12 Connecting Block
Smart Pad™ keypad, by usMounted Behind
Closed Doors
ing the 3-terminal "VGS" conROOM 1
nector on the CB12 Fig. 2 The CB12 in a Typical 3-Room IR Repeater System
(V=+12Volts, G=Gnd., S=IR
Signal). When connecting a system, follow this diagram carefully:
IR OUT
GND
PWR OUT
V G S
GND
3-Conductor
Room-to-Room
Cable
(unshielded OK)
When you use more than 1 keypad and one IR receiver together in a system, use the high current power
supply, model 782-00, in place of the 781RG.

1
Modules & Connecting Blocks
The Model CB12 provides a low cost means of connecting Xantech "Quick Connect" IR Receivers and
standard 3-wire IR Receivers to one single or one dual emitter and a power supply in an infrared repeater
system.
The OUT port can drive any of the Xantech emitter models in the 282, 283, 284 and 286 series as well as
the 286M shown in Fig. 2.NOTE: Be sure the Power Supplies, in any of these systems, are plugged into
an unswitched AC outlet. This maintains the system in "stand-by" operation so that power-on commands
can be sent to the controlled equipment.INSTALLATION (cont'd)
Fig. 3 illustrates another application of the CB12. In this case it serves as a "break-out" block for the
convenient connection of a 291 IR Receiver to a 3-conductor room-to-room cable in a larger multiroom
system. You may also use it with any other Xantech quick-connect IR Receiver, such as the 490-30, for
the same purpose.
INSTALLATION NOTES:
1. When used as a "break-out" block, you do not need to connect a power supply to the "PWR" jack on
the CB12. Power is supplied on the 3-conductor cable coming from the connecting block in the
equipment room.
Also, do not plug an emitter into the "OUT" jack in this case. To do so will prevent operation of the
emitters in the equipment room.
2. When paralleling IR receivers, a maximum of 12 is recommended. More than this may result in
unreliable operation due to the buildup of IR noise.
3. The Smart Pad™ keypads may be paralleled in larger numbers. They are not subject to the IR noise
limitation.
4. Mounting: The CB12 may be mounted on any flat surface using the double-sided adhesive tape
supplied.
ROOM 2
ROOM 3
ROOM 4
291 IR Receiver
X
J-BOX RECEIVER
+12V
X
IR OUT
CB12
PWR OUT
Connecting
Block
+12 VDC
780-10
®
Hand Held
Remote
(See Text)
3-Wire
Cable
GND
+12V
480-00
Dinky Link™
IR Receiver
780-10
J-Box
IR Receiver
Red
Stripe
IR OUT
IR OUT
GND
GND
IR
RCVR
Smart
Pad™
Power
Supply
Connecting Block
Mouse Emitter
VCR
EMITTERS
IR IN
Emitter
AV Receiver
789-44
GND
STATUS
®
IR
RCVR
CONNECTING BLOCK
12VDC
282M
+12 VDC
3-Conductor Room-to-Room Cable
24 to 18 gauge (unshielded OK)
Satellite Receiver
282M
789-44
GND
IR OUT
+12V
V G S
To 120 V AC
(unswitched)
782-00
283M
Blink IR Emitter
286M
490-30 Series
Micro Link™
IR Receivers
Dual Blink IRs
(to other
controlled
devices)
MAIN ROOM 1, EQUIPMENT CABINET, ETC.
Fig. 3 The CB12 used as a "Break-Out" Block
NOTE: Be sure the power supplies, in any of these systems, are plugged into an un-switched AC outlet.
This maintains the system in "stand-by" operation so that power-on commands can be sent to the controlled
equipment.