Indicator i 30
04-52-00-1 MU - 11/2012
WWW.PRECIAMOLEN.COM
User manual
This guide is intended for users of indicator i 30.
It allows a quick start of the device. For the electrical connection
and installation, refer to the following manuals :
• Wiring block diagram : 04-50-00 DD
• Installation Manual : 04-52-00 MI
Before first use, check the parameters for
the application in configuration mode.
Safety
For devices connected through a power outlet, standard
NF EN 60 950 calls for the base of this outlet to be installed near
the equipment and to be easily accessed. For equipment connected
permanently to mains, an easily accessible cut-off device must be
included to the permanent installation.
Contents
Foreword
Documentary conventions ..............................................................................................
2
Recommendations .........................................................................................................
2
Overall view
Keyboard ........................................................................................................................
3
Navigation principle ........................................................................................................
4
Screen ............................................................................................................................
5
Help area - Detail of the indication of valid keys ............................................................
6
Basic parameters ...........................................................................................................
6
Operator functions
Introduction .....................................................................................................................
7
Switching-on ...................................................................................................................
7
Reset ..............................................................................................................................
8
Taring .............................................................................................................................
8
Initial reset ......................................................................................................................
8
Reminder of gross ..........................................................................................................
9
Visualization of information ............................................................................................
9
Metrological screen ........................................................................................................
10
Operator Parameter
Introduction .....................................................................................................................
11
Manually entry of a tare value (preset tare) ....................................................................
11
High resolution display ...................................................................................................
12
Reminder of gross ..........................................................................................................
12
Consult DSD ...................................................................................................................
13
Operator configuration
Introduction .....................................................................................................................
14
Configuration the parameters .........................................................................................
14
Saving ............................................................................................................................
15
Error messages
04-52-00-1 MU
1
Indicator i 30
Foreword
$ Documentary conventions
%
Pictograms
N Important warning concerning the safety of persons.
P
O
Remark concerning the preservation and proper maintenance of the
equipment.
Note designed to :
- Facilitate reading the manual;
- Implement the equipment optimally.
%
Terminology and abbreviations
Menu options or parameters are noted :
• OPERATOR / OPTION 1 / OPTION 2... / PARAMETER
or
• INSTALLER / OPTION 1 / OPTION 2... / PARAMETER
In this manual, the functions are all executed in OPERATOR mode, the notations are
abbreviated as follows :
• OPTION 1 / OPTION 2...
2 / PARAMETER
$ Recommendations
For optimum equipment accuracy and preservation :
• Do not subject the weighing instrument (the scale) to shocks or overloads.
• Do not store a load on the weighing instrument ; discharge it as soon as the
weighing has been completed.
• Never use solvents or abrasives products for cleaning.
2
04-52-00-1 MU
Overall view
$ Keyboard
Function
O
M
m+O
E
m
R
u
< >
d
Z
t
B
04-52-00-1 MU
On / Off
Application / Metrology
Configuration mode
Exhaust
Menu
Confirmation
Directional keys
Press and hold to turn the indicator on.
Toggles between the two operating modes.
Keep these keys pressed to turn on the power
indicator in configuration mode.
Exit a menu or the entry in progress without taking
it into account.
Allows entering configuration mode by pressing
and holding the power on key.
Entry in a menu or take the current entry into
account.
Navigating in the menu or list options.
Indication < > in the help area.
Reset
Taring
Reminder of gross
3
Indicator i 30
$ Navigation principle
• The navigation keys allow moving through menus and lists of predefined values.
They are active when the symbols < > are displayed in zone 3 of the screen (See
“Screen”, page 5.):
< >
R
1. Scroll through the options at the same level (or the
possible values).
2. Confirm the selected option (or the selected value).
• In the same case, for the consultation of recorded values :
< >
Scroll through the displayed information.
• Entering an alphanumeric value :
< >
u
d
1. Reach the previous or next position in the string to enter.
2. Enter a character : select next or previous character in
alphabetical (or numeric) order.
• In case of navigation error :
E
Exit a menu, a section or option (up one level).
• Reach the backup option (configuration mode) :
E
4
Go back up to the highest configuration menu level to
achieve the backup option.
Actuate the button repeatedly, if necessary.
04-52-00-1 MU
$ Screen
5
1
8888.888
d
k
4
888
3
8888888888 W z
i
.
7
6
2
Function
Title / Symbol
1.
Weight areas
2.
User area
3.
Help area
4.
kg g t lb
5.
D
6.
W1 W2
i
z
7.
04-52-00-1 MU
.
Use
Display digital data : weight, number of pieces, calculated
data.
Indications to the attention of the user.
- NET indication if tare taken into account.
- Addition to unit.
- Indication of valid keys.
See details below.
Unit.
- Application mode :
Symbol D displayed. The displayed weight is not a
metrological reference.
- Metrological mode
No symbol. The displayed weight is not a metrological
reference.
Measuring range : Range 1 or 2 is active.
The weight is unstable.
The weight is in the zero and stable zone.
Confirmation of the touch of a button.
5
Indicator i 30
$ Help area - Detail of the indication of valid keys
0-9
Numeric entry.
0-Z
Alphanumeric entry.
1-6
Numeric entry between two specified values (ex. : between 1 and 6).
<>
Indication of a menu (even if there is only one option).
ESC
Output of a screen showing data in display only.
$ Basic parameters
%
Language
• PARAMETERS / LANGUAGE
Choose French or English.
%
Display device
• PARAMETERS / DISPLAY / ECO MODE allows adjusting the selftermination :
ON
Turn off the backlight after 30 seconds of inactivity, weight to zero.
OFF
Not self-extinguishing backlight.
• PARAMETERS / DISPLAY /BRIGHTNESS
BRIGHTNESS allows adjusting the backlight
intensity : 3 termination levels.
• PARAMETERS / DISPLAY / COLOR allows setting the screen background
colour : 7 possible colours.
N The
choice of a colour other than white no longer allows displaying
the application mode text in colour.
%
Date and time
• PARAMETER / DATE/TIME
Changing this parameter does not result in requesting a backup. It occurs
automatically after setting the time.
6
04-52-00-1 MU
Operator functions
$ Introduction
The operator functions are available from the moment power is applied to the indicator.
$ Switching-on
1. The instrument performs a self-test.
Check the proper operation of the display
screen (no defective segments).
8888.888
.
.
2. The software version is displayed.
3. The self-test is completed, the instrument
initiates the measurement and it is ready for
use.
k
888
0
6
8888888888 W z
i
v 0.0.34
0
BRIDGE i30
04-52-00-1 MU
md
d
k
z
7
Indicator i 30
$ Reset
The reset function allows ensuring the instrument reset when the load receiver is empty
and the weight displayed is not zero, (This function is limited to ± ± 2% of the maximum
instrument range from the initial zero in regulated use or to a configuration value outside the
legal metrology).
1. Empty receiver, the weight displayed is different
from zero.
240
d
k
BRIDGE i30
2. Select the reset function (Z).
The weight displayed is reset.
0
BRIDGE i30
d
k
z
$ Taring
The taring function allows storing the weight of the load in place on the receiver
(container) as the tare value and then get the net weight of the product
(displayed weight = current weight - tare). Thus the NET weight is viewed as positive when
loading and negative in case of unloading).
1. Place the container on the load receptor.
260
d
k
BRIDGE i30
2. Select the taring function (T).
The weight displayed is the net weight.
0
BRIDGE i30
d
k
NET
z
$ Initial reset
This reset can be done when the indicator turns on. To do this, when switching on, the
user presses button T until the unit starts. This zero is the reference to other reset devices.
8
04-52-00-1 MU
$ Reminder of gross
1. The result of a weighing is displayed in net.
2.340
d
k
NET
BRIDGE i30
2. Press key B.
The screen changes colour (cyan) and the result
is displayed as gross weight for a few seconds.
2.600
d
k
BRIDGE i30
$ Visualization of information
Press the < and > keys to scroll through the available information.
1. Bridge name,
200
200
200
10.000
d
k
BRIDGE i30
2. Status of lights,
d
k
LT1 LT2
3. Time,
d
k
16:37:48
4. Message from lock.
d
k
OUTSIDE
04-52-00-1 MU
9
Indicator i 30
$ Metrological screen
The following information are only accessible
from the metrology menu (M)
1. Press key > to view the metrological data.
The corresponding information are:
• MAX : Maximum device range (A).
• e : level (B).
• Event.Cnt (C).
MAX
A
e
B
:
50000kg
:
1kg
Event.Cnt:
C
10
1
:
0
0
0
0
0
0
k
z
k
z
k
z
k
z
k
z
k
z
04-52-00-1 MU
Operator Parameter
$ Introduction
Once in the metrological screen (M), press key m to access the parameterization
operator. Then use the key < and > keys to access the different functions available.
$ Manually entry of a tare value (preset tare)
This function allows you to manually enter a tare value for the net weight display from 0
to MAX (0 to cancel the preset tare).
4.180
1. Select the preset tare function PT and confirm it
(R).
d
k
< >
PT
4.180
2. The current value of the tare weight is displayed.
0
4.180
keys.
u et d:
Change the value of the
selected digit.
•
< and> : Move from one digit to another.
240
The value is taken as the tare value. The
weighing result is now viewed on the Net.
04-52-00-1 MU
T:
d
k
0-9
kgD
3.940
4. Confirm the new value (R).
0-9
kgD
3. Enter the new tare value by pressing the arrow
•
d
k
k
NET
0.170 KG
11
Indicator i 30
$ High resolution display
4.180
1. Switch to metrology mode (M).
MAX
functions with the arrow keys.
3. Select the HR function then confirm (R).
k
< >
HR
4. The result is displayed with the precision
associated with high resolution during a few
seconds in Legal Metrology and remains
permanent outside Legal Metrology.
:
4.180
2. Press key m and scroll through the various
k
MAX
4178
d
k
:
$ Reminder of gross
3.940
1. Switch to metrology mode (M).
MAX
functions with the arrow keys.
3. Select the B-G function then confirm (R).
12
k
< >
G-N
4.180
4. The screen changes colour (cyan) and the result
is displayed as gross weight for a few seconds
in Legal Metrology and is permanent outside
Legal Metrology.
:
3.940
2. Press key m and scroll through the various
k
NET
MAX
d
k
:
04-52-00-1 MU
$ Consult DSD
1. Switch to metrology mode (M).
2. Press key m and scroll through the various
functions with the arrow keys.
MAX
:
3. Select the DSD function then confirm (R).
DSD.
DSD REF.
DSD NUM
0
349
0
RECORD
0
(R).
READ DSD
5. Select the DSD NUM function then confirm
(R).
6. Enter the number of the record to see the keys
< and > then confirm.
Remark: Enter 0 to display the last recording.
7. Confirm again to display the information
corresponding to the file.
04-52-00-1 MU
0
0
0
4. Select the READ DSD function then confirm
or select function REF. DSD then confirm
(R).
This reference allows identifying a bridge.
0
k
k
< >
k
< >
k
< >
k
< >
k
0-9
k
< >
13
Indicator i 30
Operator configuration
$ Introduction
Simultaneously press keys m + O at power-on or at restart of the indicator to access
the operator configuration.
$ Configuration the parameters
These parameters are accessible from the configuration menu.
1. Access to the configuration menu.
LOGIN / OPERATOR / APP.
For MEASUREMENT and PARAMETERS menus, refer to the installation guide
(04-52-00 MI).
2. Fill the BRIDGE NAME parameter.
This parameter allows you to assign a name to the bridge of up to 10 characters.
3. Fill the LOCK MSG parameter.
This parameter allows choosing the message to be displayed when the presence
threshold is reached and the LOCK entry is active.
4. Fill the LOCK WT parameter.
This parameter is active when the LOCK entry is active:
• YES⇒ the weight is displayed in red on the screen.
• NO⇒ the weight is not displayed.
5. Fill the PRES THRES parameter.
The following two parameters are configured by the installer.
6. Fill the LIGHT1.NAME parameter.
This parameter allows you to assign a name to the entry light.
7. Fill the LIGHT2.NAME parameter.
This parameter allows you to assign a name to the exit light.
14
04-52-00-1 MU
$ Saving
When the configuration parameters have been changed, the backup can be done in two
ways :
- By going back to the highest level in the configuration menu:
- by pressing key O..
menu
< >
SAVE
The SAVE option screen is displayed for about 1 s,
then the choice whether or not to confirm the modified
parameters is proposed.
NO
save
< >
Select NO to return to the
configuration menu without saving the
modified parameters.
04-52-00-1 MU
YES
save
< >
Select YES to return to the
configuration menu after saving up the
modified parameters.
15
Indicator i 30
Error messages
1. Instrument under-loaded.
• Check the load receptor.
• Reset to zero.
2. Instrument overloaded.
• Remove part of the load.
3. Command denied
• Example : Taring with unstable weight
4. Reset denied
The weight limit for this function has been
exceeded.
• Remove the load and press the reset key.
16
_______
+++++++
d
-------
d
-------
d
E26
d
E40
04-52-00-1 MU
WWW.PRECIAMOLEN.COM
WWW.PRECIAMOLEN.COM
Head Office & Plant PRECIA-MOLEN
BP 106 - 07000 Privas - France
Tel.
33 (0) 475 664 600
Fax
33 (0) 475 664 330
E-MAIL
[email protected]
www.preciamolen.com
RCS: 386 620 165 RCS Aubenas