Download Eco-POWER METER - uwe electronic GmbH
Transcript
KW4M Eco-POWER METER ■Dimensions (mm inch) ■Terminal Layouts and Wiring Diagrams General tolerance: ±1.0 ±.039 11-pin type 5.5 .217 ●Single-phase, two-wire connection 87.5 3.445 Power supply side Panasonic EcoPOWER METER MODE Lock 1 2 OP CT1 3 4 CT2 SET TIME COUNT V CHARGE CT1 K L CT1 K L 1 2 Output RS485 Output When using VT (䡺44.5) (䡺1.752) MODE KW4M *One current transformer (CT) is required for measurement with single-phase, two-wire systems. 14.5 .571 + - + - + - 56 7 4 3 2 kW/kWh A Load side Eco-POWER METER When using VT 6 7 8 9 10 11 1 2 3 4 5 8 9 10 1 11 Simple Wattmeter + - RS485 KW4M 䡺48 䡺1.890 ●Single-phase, three-wire and three-phase, three-wire connections 73 2.874 *Two current transformers (CT) are required for measurement with single-phase, three-wire and three-phase, three-wire systems. Screw terminal type (M3.5) 5.5 .217 Power supply side CT1 K L CT2 K L RR1 NS2 TT3 When using VT (䡺44.5) (䡺1.752) RS485 Output + - + - 56 7 4 8 3 9 2 10 1 11 No. 1 2 3 4 5 6 7 8 9 10 11 Load side 6 7 8 9 10 11 1 2 3 4 5 On the lookout for wasted electricity in buildings and plants + RS485 ●Terminal layouts 81.9 3.224 When using VT Output + - CT1 K L CT2 K L 11-pin type 1, R, R 2, N, S 3, T, T RS-485 (+) RS-485 (–) Pulse output (+) Pulse output (–) CT1 (K)/IN CT1 (L), CT2 (L) CT2 (K) 0V Screw terminal type RS-485 (–) CT1 (K)/IN CT1 (L), CT2 (L) CT2 (K) 0V Pulse output (+) Pulse output (–) 1, R, R 2, N, S 3, T, T RS-485 (+) • For correct usage, please read “Installation Instructions” thoroughly before using. • For details, specifications and handling, please refer to the KW4M Eco-POWER METER user’s manual. • The user’s manual can be downloaded from http://www.nais-e.com/download/index.html. KW4S Eco-POWER METER 1. Electricity meter that acts like an industrial component (DIN size: 48×48) 3. Log and track data of integrated electrical energy usage Eco-POWER METER is both compact and inexpensively priced. It is easy to install on your existing equipment and machinery. It is easy to load the power usage pulse output into a PLC or counter. 2. Digitally display integrated electrical energy and electricity charges You can digitally display integrated electrical energy, voltage, current, and electricity charges. This is handy for managing energy-saving. 4. Centrally manage integrated electrical energy, voltage, and current Adopts the RS485 for communication specification. This allows you to log data (integrated electrical energy, voltage, and current) from up to 99 units on a PC and PLC. Dedicated CT ● Product types Product name Eco-POWER METER main unit Dedicated current transformer (CT) Data collection software for Eco-POWER METER Phase and wire system Rated input Dedicated CT (DIN48x48 size) Eco-POWER METER Current transformer Terminal type Screw terminal Single-phase two-wire system Dedicated CT type 100 to 120/ 11-pin Single-phase three-wire system 200 to 240V AC Screw terminal Commercial CT type Three-phase three-wire system (Rated secondary current: 1 A) 11-pin Only used for AKW4111, AKW4211 Part No. AKW4111 AKW4211 AKW4121 AKW4221 AKW4801 AKW4805 For maintenance and control in Integrated applications involving energy saving electrical Voltage energy and environmental protection Electricity charge Keeping a watchful eye. Large display for increased visibility • Please refer to “Eco-3 Brothers (ARCT1B226E)” catalog. Current Eco-3 Brothers These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Please contact .......... Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ Expanded basic functions Eco-POWER METER 1 model supports 4 compact CTs Eco-COUNT METER *When using external Supports 400 V AC power measurement voltage transformer Eco-HOUR METER KW4M Eco-POWER METER ARCT1B256E '05.6 All Rights Reserved © 2005 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B256E 200506-3YT Specifications are subject to change without notice. Printed in Japan. http://www.nais-e.com/ Panasonic...the new name for 02/2006 New Matsushita Electric Works, Ltd. On the lookout for wasted electricity! KW4M Eco-POWER METER Features and Specifications FEATURES SPECIFICATIONS ●Measurement items Dedicated CT Supports 4 types of dedicated CT sensors to cover wide measuring range Item Instantaneous electrical power Unit kW Covers a wide measuring range with support for 4 types of CT (current transformer: sold separately). Also supports 5 A CT of secondary current input. *4 types of dedicated CT: 5 A/50 A, 100 A, 250 A, and 400 A Integrated electrical energy kWh MWh 5A/50A 250A Current Voltage Support for 400 V AC power measurement Capable of 100 V to 400 V AC power measurement. (If 240 V AC or higher, use with external voltage transformer.) 100A Electricity charge *1 Basic functions expanded for easier operation 400A Easy operation with shortcut key Letters are easy to read with 16-segment LCD Instantaneous electrical power/ Integrated electrical energy Hour meter ■ Instantaneous electrical power display is possible in addition to integrated electrical energy. ■ For all power supplies each phase voltage and current display are possible. ■ Built-in hour meter function. ■ Ability to display an integrated measured power range of up to 9999.99 MWh. Precise power surveillance is possible by being able to display down to two decimal places. Also, the display can be expanded from a 6-digit to a 9-digit display, making it is possible to display up to 9999999.99 kW. Since “Instantaneous electrical power” can be displayed, you can instantly verify the power being used at the current time. Pulse input Electricity charge (yen/dollar/euro/yuan) CT is 1/3 the size of our previous models to save space and install more easily. Charge display supports four currencies: yen, dollar, euro, and yuan. A compact CT (current transformer) is used that is approximately 1/3 the size of previous models. Voltage (1-2/2-3) Load time (ON/OFF) Since an hour meter function is built in, you can measure the power-on time that is over or under the control current. Easily connects to PLC Count value/Preset value A counter function is built in. By using this “pulse input”, surveillance other than the electrical power is possible of the integrated energy in the air or a gas. ●Communication An RS485 communications port comes standard. Up to 99 units can be connected to a PLC (when using our recommended model). Using MEWTOCOL as the protocol, it is easy to connect to a DLU (Web Datalogger Unit). Interface Protocol Number of connected units Transmission distance Conforming to RS485 MEWTOCOL Max. 99 units Max. 1,200m Input mode Max. counting speed Pulse input Input signal Output mode Number of digits Addition (fixed) 2 kHz/30 Hz (selectable by mode) Min. input signal width: 0.25 ms (when 2 kHz selected)/16.7 ms (when 30 Hz selected) ON : OFF ratio = 1 : 1 Contact/No contact (open collector) • Impedance when shorted: 1 kΩ • Residual voltage when shorted: Max. 2 V • Impedance when open: 100 kΩ HOLD (over count) 6 digits display (0 to 999999) (selectable by mode) Pulse output (transistor output) Number of output points Insulation method Output type Output capacity Pulse width ON state voltage drop OFF state leakage current Pulse When measuring power output unit *2 When measuring pulse input 1 point Optical coupler Open collector 100mA 30V DC Approx. 100ms 1.5V or less 100 µA or less 0.001/0.01/0.1/1/10/100 kWh/Alarm (selectable by mode) HOLD (over count) *2 Power and pulse input are not possible at the same time. System configuration examples PRODUCT TYPES ● Main unit 1 Electric power watching in manufacturing lines ●Dedicated current transformer (CT) Phase and wire system Single-phase two-wire system Single-phase three-wire system Three-phase three-wire system Pulse input 100 to 120/200 to 240V AC 50/60 Hz common 8VA 85 to 132/170 to 264V AC (85% to 110% of rated operating voltage) 10ms –10°C to +50°C (Storage temperature: –25°C to +70°C –13°F to 158°F) 30 to 85%RH (at 20°C non-condensing) Ambient humidity With Backlight 6-digit, 7-segment LCD for settings Display method and 4-digit, 16-segment LCD for modes. Upper display: green, Lower display: amber Power failure memory method EEP-ROM (Over 100,000 overwrites) IP66 (front panel with rubber gasket) Protective construction Note: Waterproofing (IP66) will be lost in continuous (permanently attached) installations. For 11-pin type: approx. 130 g, Mass For Screw terminal type: approx. 140 g Rated operating voltage Rated frequency Rated power consumption Allowable operating voltage range Allowable power off time Ambient temperature (9-digit display shown.) 0.00 to 9999.99kWh to 10.00MWh to 9999.99MWh 9-digit display: 0.00 to 9999999.99kWh 0.0 to 999.9 A 0.0 to 999.9 A 0.0 to 9999.9 V 0.0 to 9999.9 V 0 to 999999 JPY 0 to 9999.99 $ 0 to 9999.99 EUR 0 to 9999.99 CNY 0.0 to 99999.9 h (Hour) 0.0 to 99999.9 h (Hour) 0 to 999999 Count *1: Electricity charge is designed chiefly for managing energy saving. It is not intended to be used for billing. ●Main unit ■ Built-in pulse input function (cannot be used when measuring power). Current (L1/L2) L1 (CT1) phase current L2 (CT2) phase current Voltage between 1-2 Voltage between 2-3 Yen Dollars Euros Yuan ON time OFF time Data range 0.00 to 9999.99 Rated input 100 to 120/ 200 to 240V AC Current transformer Dedicated CT type (5 A/50 A/100 A/ 250 A/400 A) Terminal type Part No. Screw terminal AKW5111 11-pins AKW5211 Rated primary current 5A/50A 100A 250A 400A Example Part No. AKW4801 AKW4802 AKW4803 AKW4804 Electric power watching using PLC with Eco-POWER METER E-mail function also included 2 Electric power data collection and remote watching of plants and buildings Example Electric power watching using Web Datalogger Unit with Eco-POWER METER Have your mobile phone notified by email if there is a significant increase in electric power usage. Gathering of logged data • Power meter • Water meter • Dynamometer • Gas meter Remotely manage collected data on the Web. Air PART NAME 2 3 Panasonic EcoPOWER METER MODE Lock 1 2 OP CT1 3 4 CT2 6 4 5 MODE 7 SET TIME COUNT 1 V CHARGE kW/kWh A KW4M 8 Web Datalogger Unit 1 2 3 4 5 Mode indicator (16-segment LCD) Illuminates when locked. Lock indicator Illuminates when setting a mode. Mode indicator Illuminates during pulse output. Output indicator Illuminates when the CT direction is correct and a CT direction current flows that exceeds the set current value. notification display 6 Value display Displays the integrated power, momentary power, current, voltage, electricity charge, hour meter time, (7-segment) Air Air PCWAY (Operation Data Managing Software) FPΣ Using RS485 (reduced wiring with two twisted pair cables), up to 99 Eco-POWER METERs can be connected. con ditio ner, Ligh ts, ditio ner, con ditio ner, Ligh ts, Ligh ts, 7 MODE key 8 SET key 9 Select key Supermarket Internet Telephone infrastructure All types of networks Used to move between different modes. Web Datalogger Unit Used to make settings. Used to move between modes. Line graph 02/2006 Outl ets Outl ets Building Pie graph Changes the item displayed. ets Ou tlets count, and all settings. 9 Outl con Food warehouse Web Datalogger Unit Plant KW4M Eco-POWER METER ■Dimensions (mm inch) ■Terminal Layouts and Wiring Diagrams General tolerance: ±1.0 ±.039 11-pin type 5.5 .217 ●Single-phase, two-wire connection 87.5 3.445 Power supply side Panasonic EcoPOWER METER MODE Lock 1 2 OP CT1 3 4 CT2 SET TIME COUNT V CHARGE CT1 K L CT1 K L 1 2 Output RS485 Output When using VT (䡺44.5) (䡺1.752) MODE KW4M *One current transformer (CT) is required for measurement with single-phase, two-wire systems. 14.5 .571 + - + - + - 56 7 4 3 2 kW/kWh A Load side Eco-POWER METER When using VT 6 7 8 9 10 11 1 2 3 4 5 8 9 10 1 11 Simple Wattmeter + - RS485 KW4M 䡺48 䡺1.890 ●Single-phase, three-wire and three-phase, three-wire connections 73 2.874 *Two current transformers (CT) are required for measurement with single-phase, three-wire and three-phase, three-wire systems. Screw terminal type (M3.5) 5.5 .217 Power supply side CT1 K L CT2 K L RR1 NS2 TT3 When using VT (䡺44.5) (䡺1.752) RS485 Output + - + - 56 7 4 8 3 9 2 10 1 11 No. 1 2 3 4 5 6 7 8 9 10 11 Load side 6 7 8 9 10 11 1 2 3 4 5 On the lookout for wasted electricity in buildings and plants + RS485 ●Terminal layouts 81.9 3.224 When using VT Output + - CT1 K L CT2 K L 11-pin type 1, R, R 2, N, S 3, T, T RS-485 (+) RS-485 (–) Pulse output (+) Pulse output (–) CT1 (K)/IN CT1 (L), CT2 (L) CT2 (K) 0V Screw terminal type RS-485 (–) CT1 (K)/IN CT1 (L), CT2 (L) CT2 (K) 0V Pulse output (+) Pulse output (–) 1, R, R 2, N, S 3, T, T RS-485 (+) • For correct usage, please read “Installation Instructions” thoroughly before using. • For details, specifications and handling, please refer to the KW4M Eco-POWER METER user’s manual. • The user’s manual can be downloaded from http://www.nais-e.com/download/index.html. KW4S Eco-POWER METER 1. Electricity meter that acts like an industrial component (DIN size: 48×48) 3. Log and track data of integrated electrical energy usage Eco-POWER METER is both compact and inexpensively priced. It is easy to install on your existing equipment and machinery. It is easy to load the power usage pulse output into a PLC or counter. 2. Digitally display integrated electrical energy and electricity charges You can digitally display integrated electrical energy, voltage, current, and electricity charges. This is handy for managing energy-saving. 4. Centrally manage integrated electrical energy, voltage, and current Adopts the RS485 for communication specification. This allows you to log data (integrated electrical energy, voltage, and current) from up to 99 units on a PC and PLC. Dedicated CT ● Product types Product name Eco-POWER METER main unit Dedicated current transformer (CT) Data collection software for Eco-POWER METER Phase and wire system Rated input Dedicated CT (DIN48x48 size) Eco-POWER METER Current transformer Terminal type Screw terminal Single-phase two-wire system Dedicated CT type 100 to 120/ 11-pin Single-phase three-wire system 200 to 240V AC Screw terminal Commercial CT type Three-phase three-wire system (Rated secondary current: 1 A) 11-pin Only used for AKW4111, AKW4211 Part No. AKW4111 AKW4211 AKW4121 AKW4221 AKW4801 AKW4805 For maintenance and control in Integrated applications involving energy saving electrical Voltage energy and environmental protection Electricity charge Keeping a watchful eye. Large display for increased visibility • Please refer to “Eco-3 Brothers (ARCT1B226E)” catalog. Current Eco-3 Brothers These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Please contact .......... Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ Expanded basic functions Eco-POWER METER 1 model supports 4 compact CTs Eco-COUNT METER *When using external Supports 400 V AC power measurement voltage transformer Eco-HOUR METER KW4M Eco-POWER METER ARCT1B256E '05.6 All Rights Reserved © 2005 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B256E 200506-3YT Specifications are subject to change without notice. 02/2006 Printed in Japan. http://www.nais-e.com/ Panasonic...the new name for New Matsushita Electric Works, Ltd. Eco-POWER METER KW4S Eco-POWER METER KW4S KW4S Eco-POWER METER System Diagram Web Datalogger Unit Up to or 99 Eco-POWER METERs can be connected! FP-e 1. Electricity meter that acts like an industrial component (DIN size: 48×48) 3. Log and track data of integrated electrical energy usage Eco-POWER METER is both compact and inexpensively priced. It is easy to install on your existing equipment and machinery. It is easy to load the power usage pulse output into a PLC or counter. 2. Digitally display integrated electrical energy and electricity charges You can digitally display integrated electrical energy, voltage, current, and electricity charges. This is handy for managing energy-saving. PC used for data gathering and management 4. Centrally manage integrated electrical energy, voltage, and current Dedicated CT Phase and wire system Installation is easy using a CT even for the power lines of existing equipment and machinery. CT • Please see the catalog (ARCT1E208E) for details on the Web Datalogger Unit. • Please see the “FP series Programmable Controllers” catalog (ARCT1B230E) for details on the FP-e and FP0 PLC. 1) Pin type 䡺48 䡺1.890 2) Screw terminal type 87.5 3.445 5.5 .217 14.5 .571 mm inch 5.5 .217 Just attach the dedicated CT to your existing cables. There is no need to install any additional cabling. Two installation methods are available: The extremely easy-to-use one-touch installation, and the installation frame installation, used for timers/counters (protective construction IP66). Select the installation type that suits the location. SET CHARGE Terminal type Screw terminal 11-pins Screw terminal 11-pins (䡺44.5) (䡺1.752) kWh Product Name Eco-COUNT METER main 81.9 3.224 Now even more powerful with communication function and easy PLC connection! CT 6. Letter's height is 8.7 mm A large LCD panel is used, with a highly legible 8.7 mm letter’s height. Eco-COUNT METER Eco-HOUR METER Building 7. Conform to CE marking (EMC directive) Plant Intermediate power unit*1 Installation type Installation frame type*2 One-touch installation type Front reset Measurement count range Available 0 to 99999999 Installation type Installation frame type*2 One-touch installation type Front reset Measurement count range Available 0 to 99999.9h cable*3 Part No. AKC2421 AKC2621 AKE2811 Air conditioner PC Line process Lights Elevator Constant-temperature oven KE2S Eco-HOUR METER Types and Specifications Product Name ●Types Eco-HOUR METER main Current Changes Communication protocol Only dedicated protocol Dedicated protocol and MEWTOCOL Station number setting 1 to 31 1 to 99 (Note) Communication format setting Setting start → Communication format change Setting start → Protocol switch (dedicated or MEWTOCOL) → Communication format change unit*1 Intermediate power cable*3 Features added — Eco-3 Brothers These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Above content and communication procedure added. Note: You must use 1 to 31 when selecting the dedicated protocol (Eco-POWER METER data collection software: AKW4805). ●Communication specifications Conforming to RS485 Our method Isolated with internal circuit 99 units* 1,200m 2,400, 4,800, 9,600, 19,200 bps (In each setting mode, settings can be made with front panel keys.) 7-bit/8-bit (In each setting mode, settings can be made with front panel keys.) Not available/Odd/Even (In each setting mode, settings can be made with front panel keys.) 1 bit (Fix) Half duplex Start-stop synchronous method Approx. 120Ω (internal) Part No. AKE2421 AKE2621 AKE2811 Notes: 1. Eco-HOUR METER (AKE2421/AKE2621) is a product package consisting of the main unit, an exclusive use current transformer (CT), and trunk cable. 2. Only the installation frame installation type includes rubber gasket and installation frame. 3. The maximum allowable current of the intermediate power cable is 15 A. Change Interface Protocol Isolation status No. of connected units Transmission distance Transmission speed (Baud rate) Data length Transmission Parity data format Stop bit Communication method Synchronous method Terminating resistor On the lookout for wasted electricity! KC2S Eco-COUNT METER A 73 2.874 Instruction Manual Part No. AKW4111 AKW4211 AKW4121 AKW4221 AKW4801 AKW4805 ●Product types (䡺44.5) (䡺1.752) V 3. Economically priced 4. Compact size doesn't take up space (DIN 24 x 48) Easy to install even in cramped spaces. Eco-POWER METER KW4S MODE Commercial CT type 5. Two installation methods available (Separate models) 2. Built-in battery Dimensions Display: Integrated electrical energy, Voltage, Current and Electricity charge Dedicated CT type 1. Easy to install on existing machinery The built-in battery allows the units to be installed anywhere. ●Eco-POWER METER KW4S Current transformer KC2S Eco-COUNT METER/KE2S Eco-HOUR METER Shrink-wrapping machine KW4S Eco-POWER METER Only used for AKW4111, AKW4211 Dedicated current transformer (CT) Data collection software for Eco-POWER METER Power line Rated input Single-phase two-wire system 100 to 120/ Single-phase three-wire system 200 to 240V AC Three-phase three-wire system Eco-POWER METER Main unit Simple Watt-Hour Meter Adopts the RS485 for communication specification. This allows you to log data (integrated electrical energy, voltage, and current) from up to 99 units on a PC and PLC. ●Product types Product name Eco-POWER METER Please contact .......... ●MEWTOCOL-COM commands Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ The Eco-POWER METER supports five commands. RD: Data area read command WD: Data area write command MD: Monitor data save and save reset command MG: Monitor execute command For maintenance and Integrated Electricity electrical Voltage Current charge control in applications energy Keeping a watchful eye. involving energy saving and environmental protection Eco-POWER METER Eco-COUNT METER Eco-HOUR METER RT: Status read command *We recommend the SI-35 of Lineeye Co., Ltd., for the RS485 converter on the PC side. (When using SI-35, FP2-CB485 (for FP2-MCU), FPΣ (COM3 and COM4) or FP-e, the maximum number you can connect is 99. When using with devices other than these, the maximum number will be limited to 31.) Eco-POWER METER KW4S ARCT1B247E ’05.1 All Rights Reserved © 2005 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B247E 200501-3YT Specifications are subject to change without notice. Printed in Japan. 02/2006 Eco-POWER METER KW4S 1 Eco-POWER METER KW4S Always on the lookout for wasted electricity, Eco-POWER METER is there to assist in the energy-saving activities of all customers. Electric power measurement for individual equipment and machines Example 4 Electric power watching in manufacturing lines Example Measure electric power easily with Eco-POWER METER. Configuration Examples (Alone and as system) Easy connection 1. Standalone measurement Electric power watching using PLC with Eco-POWER METER Email function also included Have your mobile phone notified by email if there is a significant increase in electric power usage. Eco-POWER METER GD breaker Measuring electric power with Eco-POWER METER and dedicated CT. Back Front 4. Gathering data with PLC Clamp a CT below the machine’s power supply breaker and measure the power consumption with the Eco-POWER METER. PCWAY Dedicated CT (Operation Data Managing Software) FPΣ Using RS485 (reduced wiring with two twisted pair cables), up to 99 Eco-POWER METERs can be connected. MEW TOC OL t utpu eo Puls Dedicated CT Pie graph 2. Data management with PLC 5. Managing data with Web Datalogger Unit Shrink-wrapping machine 3. Data(Using management with computer data collection software) • Please see the catalog (BBCT1B146N) for details about the GD breaker. 2 3 Alarm output when heater is ready for replacement Example Example Easy systemization Eco-POWER METER pulse output function Gathering power consumption data from each manufacturing machine Automatic gathering of electrical power Line graph 5 Electric power data collection and remote watching of plants and buildings Example Electric power watching using Web Datalogger Unit with Eco-POWER METER 1 Electric power measured by the Eco-POWER METER is Gathering of logged data output as pulses and then measured at a PLC (FP0). • Power meter • Water meter • Dynamometer • Gas meter 2 1 FP0 Data from each machine is collected using the Eco-POWER METER dedicated data collection software (AKW4805) and then saved as a CSV file. Using spreadsheet software such as Excel, data can be freely edited (turned into graphs) and saved. Daily and monthly reports can be created. Using RS485 (reduced wiring with two twisted pair cables), up to 31 Eco-POWER METERs can be connected. Air diti integrated electric power and when the value exceeds a certain amount, the heater power supply output is turned off. one r Remotely manage collected data on the Web. Lig hts t Supermarke 2 The pulses are converted to Dedicated CT con Supermarket Web Datalogger Unit Internet Telephone infrastructure All types of networks Off ice aut om atio n Ou tlet s Building Electromagnetic switch Heater Shrinkwrapping machine • Please see the catalog (BBCT1B135) for details about the electromagnetic switch. 02/2006 Web Datalogger Unit Food warehouse Web Datalogger Unit Plant Eco-POWER METER KW4S 1 Eco-POWER METER KW4S Always on the lookout for wasted electricity, Eco-POWER METER is there to assist in the energy-saving activities of all customers. Electric power measurement for individual equipment and machines Example 4 Electric power watching in manufacturing lines Example Measure electric power easily with Eco-POWER METER. Configuration Examples (Alone and as system) Easy connection 1. Standalone measurement Electric power watching using PLC with Eco-POWER METER Email function also included Have your mobile phone notified by email if there is a significant increase in electric power usage. Eco-POWER METER GD breaker Measuring electric power with Eco-POWER METER and dedicated CT. Back Front 4. Gathering data with PLC Clamp a CT below the machine’s power supply breaker and measure the power consumption with the Eco-POWER METER. PCWAY Dedicated CT (Operation Data Managing Software) FPΣ Using RS485 (reduced wiring with two twisted pair cables), up to 99 Eco-POWER METERs can be connected. MEW TOC OL t utpu eo Puls Dedicated CT Pie graph 2. Data management with PLC 5. Managing data with Web Datalogger Unit Shrink-wrapping machine 3. Data(Using management with computer data collection software) • Please see the catalog (BBCT1B146N) for details about the GD breaker. 2 3 Alarm output when heater is ready for replacement Example Example Easy systemization Eco-POWER METER pulse output function Gathering power consumption data from each manufacturing machine Automatic gathering of electrical power Line graph 5 Electric power data collection and remote watching of plants and buildings Example Electric power watching using Web Datalogger Unit with Eco-POWER METER 1 Electric power measured by the Eco-POWER METER is Gathering of logged data output as pulses and then measured at a PLC (FP0). • Power meter • Water meter • Dynamometer • Gas meter 2 1 FP0 Data from each machine is collected using the Eco-POWER METER dedicated data collection software (AKW4805) and then saved as a CSV file. Using spreadsheet software such as Excel, data can be freely edited (turned into graphs) and saved. Daily and monthly reports can be created. Using RS485 (reduced wiring with two twisted pair cables), up to 31 Eco-POWER METERs can be connected. Air diti integrated electric power and when the value exceeds a certain amount, the heater power supply output is turned off. one r Remotely manage collected data on the Web. Lig hts t Supermarke 2 The pulses are converted to Dedicated CT con Supermarket Web Datalogger Unit Internet Telephone infrastructure All types of networks Off ice aut om atio n Ou tlet s Building Electromagnetic switch Heater Web Datalogger Unit Shrinkwrapping machine Food warehouse • Please see the catalog (BBCT1B135) for details about the electromagnetic switch. 02/2006 Web Datalogger Unit Plant Eco-POWER METER KW4S 1 Eco-POWER METER KW4S Always on the lookout for wasted electricity, Eco-POWER METER is there to assist in the energy-saving activities of all customers. Electric power measurement for individual equipment and machines Example 4 Electric power watching in manufacturing lines Example Measure electric power easily with Eco-POWER METER. Configuration Examples (Alone and as system) Easy connection 1. Standalone measurement Electric power watching using PLC with Eco-POWER METER Email function also included Have your mobile phone notified by email if there is a significant increase in electric power usage. Eco-POWER METER GD breaker Measuring electric power with Eco-POWER METER and dedicated CT. Back Front 4. Gathering data with PLC Clamp a CT below the machine’s power supply breaker and measure the power consumption with the Eco-POWER METER. PCWAY Dedicated CT (Operation Data Managing Software) FPΣ Using RS485 (reduced wiring with two twisted pair cables), up to 99 Eco-POWER METERs can be connected. MEW TOC OL t utpu eo Puls Dedicated CT Pie graph 2. Data management with PLC 5. Managing data with Web Datalogger Unit Shrink-wrapping machine 3. Data(Using management with computer data collection software) • Please see the catalog (BBCT1B146N) for details about the GD breaker. 2 3 Alarm output when heater is ready for replacement Example Example Easy systemization Eco-POWER METER pulse output function Gathering power consumption data from each manufacturing machine Automatic gathering of electrical power Line graph 5 Electric power data collection and remote watching of plants and buildings Example Electric power watching using Web Datalogger Unit with Eco-POWER METER 1 Electric power measured by the Eco-POWER METER is Gathering of logged data output as pulses and then measured at a PLC (FP0). • Power meter • Water meter • Dynamometer • Gas meter 2 1 FP0 Data from each machine is collected using the Eco-POWER METER dedicated data collection software (AKW4805) and then saved as a CSV file. Using spreadsheet software such as Excel, data can be freely edited (turned into graphs) and saved. Daily and monthly reports can be created. Using RS485 (reduced wiring with two twisted pair cables), up to 31 Eco-POWER METERs can be connected. Air diti integrated electric power and when the value exceeds a certain amount, the heater power supply output is turned off. one r Remotely manage collected data on the Web. Lig hts t Supermarke 2 The pulses are converted to Dedicated CT con Supermarket Web Datalogger Unit Internet Telephone infrastructure All types of networks Off ice aut om atio n Ou tlet s Building Electromagnetic switch Heater • Please see the catalog (BBCT1B135) for details about the electromagnetic switch. Shrinkwrapping machine Web Datalogger Unit Food warehouse Web Datalogger Unit 02/2006 Plant Eco-POWER METER KW4S Eco-POWER METER KW4S KW4S Eco-POWER METER System Diagram Web Datalogger Unit Up to or 99 Eco-POWER METERs can be connected! FP-e 1. Electricity meter that acts like an industrial component (DIN size: 48×48) 3. Log and track data of integrated electrical energy usage Eco-POWER METER is both compact and inexpensively priced. It is easy to install on your existing equipment and machinery. It is easy to load the power usage pulse output into a PLC or counter. 2. Digitally display integrated electrical energy and electricity charges You can digitally display integrated electrical energy, voltage, current, and electricity charges. This is handy for managing energy-saving. PC used for data gathering and management 4. Centrally manage integrated electrical energy, voltage, and current Dedicated CT Phase and wire system Installation is easy using a CT even for the power lines of existing equipment and machinery. CT • Please see the catalog (ARCT1E208E) for details on the Web Datalogger Unit. • Please see the “FP series Programmable Controllers” catalog (ARCT1B230E) for details on the FP-e and FP0 PLC. 1) Pin type 䡺48 䡺1.890 2) Screw terminal type 87.5 3.445 5.5 .217 14.5 .571 mm inch 5.5 .217 Just attach the dedicated CT to your existing cables. There is no need to install any additional cabling. Two installation methods are available: The extremely easy-to-use one-touch installation, and the installation frame installation, used for timers/counters (protective construction IP66). Select the installation type that suits the location. SET CHARGE Terminal type Screw terminal 11-pins Screw terminal 11-pins (䡺44.5) (䡺1.752) kWh Product Name Eco-COUNT METER main 81.9 3.224 Now even more powerful with communication function and easy PLC connection! CT 6. Letter's height is 8.7 mm A large LCD panel is used, with a highly legible 8.7 mm letter’s height. Eco-COUNT METER Eco-HOUR METER Building 7. Conform to CE marking (EMC directive) Plant Intermediate power unit*1 Installation type Installation frame type*2 One-touch installation type Front reset Measurement count range Available 0 to 99999999 Installation type Installation frame type*2 One-touch installation type Front reset Measurement count range Available 0 to 99999.9h cable*3 Part No. AKC2421 AKC2621 AKE2811 Air conditioner PC Line process Lights Elevator Constant-temperature oven KE2S Eco-HOUR METER Types and Specifications Product Name ●Types Eco-HOUR METER main Current Changes Communication protocol Only dedicated protocol Dedicated protocol and MEWTOCOL Station number setting 1 to 31 1 to 99 (Note) Communication format setting Setting start → Communication format change Setting start → Protocol switch (dedicated or MEWTOCOL) → Communication format change unit*1 Intermediate power cable*3 Features added — Eco-3 Brothers These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink. Above content and communication procedure added. Note: You must use 1 to 31 when selecting the dedicated protocol (Eco-POWER METER data collection software: AKW4805). ●Communication specifications Please contact .......... ●MEWTOCOL-COM commands Conforming to RS485 Our method Isolated with internal circuit 99 units* 1,200m 2,400, 4,800, 9,600, 19,200 bps (In each setting mode, settings can be made with front panel keys.) 7-bit/8-bit (In each setting mode, settings can be made with front panel keys.) Not available/Odd/Even (In each setting mode, settings can be made with front panel keys.) 1 bit (Fix) Half duplex Start-stop synchronous method Approx. 120Ω (internal) 02/2006 Part No. AKE2421 AKE2621 AKE2811 Notes: 1. Eco-HOUR METER (AKE2421/AKE2621) is a product package consisting of the main unit, an exclusive use current transformer (CT), and trunk cable. 2. Only the installation frame installation type includes rubber gasket and installation frame. 3. The maximum allowable current of the intermediate power cable is 15 A. Change Interface Protocol Isolation status No. of connected units Transmission distance Transmission speed (Baud rate) Data length Transmission Parity data format Stop bit Communication method Synchronous method Terminating resistor On the lookout for wasted electricity! KC2S Eco-COUNT METER A 73 2.874 Instruction Manual Part No. AKW4111 AKW4211 AKW4121 AKW4221 AKW4801 AKW4805 ●Product types (䡺44.5) (䡺1.752) V 3. Economically priced 4. Compact size doesn't take up space (DIN 24 x 48) Easy to install even in cramped spaces. Eco-POWER METER KW4S MODE Commercial CT type 5. Two installation methods available (Separate models) 2. Built-in battery Dimensions Display: Integrated electrical energy, Voltage, Current and Electricity charge Dedicated CT type 1. Easy to install on existing machinery The built-in battery allows the units to be installed anywhere. ●Eco-POWER METER KW4S Current transformer KC2S Eco-COUNT METER/KE2S Eco-HOUR METER Shrink-wrapping machine KW4S Eco-POWER METER Only used for AKW4111, AKW4211 Dedicated current transformer (CT) Data collection software for Eco-POWER METER Power line Rated input Single-phase two-wire system 100 to 120/ Single-phase three-wire system 200 to 240V AC Three-phase three-wire system Eco-POWER METER Main unit Simple Watt-Hour Meter Adopts the RS485 for communication specification. This allows you to log data (integrated electrical energy, voltage, and current) from up to 99 units on a PC and PLC. ●Product types Product name Eco-POWER METER Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan Telephone: +81-6-6908-1050 Facsimile: +81-6-6908-5781 http://www.nais-e.com/ The Eco-POWER METER supports five commands. RD: Data area read command WD: Data area write command MD: Monitor data save and save reset command MG: Monitor execute command For maintenance and Integrated Electricity electrical Voltage Current charge control in applications energy Keeping a watchful eye. involving energy saving and environmental protection Eco-POWER METER Eco-COUNT METER Eco-HOUR METER RT: Status read command *We recommend the SI-35 of Lineeye Co., Ltd., for the RS485 converter on the PC side. (When using SI-35, FP2-CB485 (for FP2-MCU), FPΣ (COM3 and COM4) or FP-e, the maximum number you can connect is 99. When using with devices other than these, the maximum number will be limited to 31.) Eco-POWER METER KW4S ARCT1B247E ’05.1 All Rights Reserved © 2005 COPYRIGHT Matsushita Electric Works, Ltd. ARCT1B247E 200501-3YT Specifications are subject to change without notice. Printed in Japan. http://www.nais-e.com/ Panasonic...the new name for Matsushita Electric Works, Ltd. Eco-POWER METER KW4S Eco-POWER METER KW4S KW4S Eco-POWER METER System Diagram Web Datalogger Unit Up to or 99 Eco-POWER METERs can be connected! FP-e 1. Electricity meter that acts like an industrial component (DIN size: 48×48) 3. Log and track data of integrated electrical energy usage Eco-POWER METER is both compact and inexpensively priced. It is easy to install on your existing equipment and machinery. It is easy to load the power usage pulse output into a PLC or counter. 2. Digitally display integrated electrical energy and electricity charges You can digitally display integrated electrical energy, voltage, current, and electricity charges. This is handy for managing energy-saving. PC used for data gathering and management 4. Centrally manage integrated electrical energy, voltage, and current Dedicated CT Installation is easy using a CT even for the power lines of existing equipment and machinery. Single-phase two-wire system 100 to 120/ Single-phase three-wire system 200 to 240V AC Three-phase three-wire system CT • Please see the catalog (ARCT1E208E) for details on the Web Datalogger Unit. • Please see the “FP series Programmable Controllers” catalog (ARCT1B230E) for details on the FP-e and FP0 PLC. 1) Pin type 䡺48 䡺1.890 2) Screw terminal type 87.5 3.445 5.5 .217 14.5 .571 mm inch 5.5 .217 Just attach the dedicated CT to your existing cables. There is no need to install any additional cabling. Two installation methods are available: The extremely easy-to-use one-touch installation, and the installation frame installation, used for timers/counters (protective construction IP66). Select the installation type that suits the location. SET CHARGE Terminal type Screw terminal 11-pins Screw terminal 11-pins Part No. AKW4111 AKW4211 AKW4121 AKW4221 AKW4801 AKW4805 On the lookout for wasted electricity! Now even more powerful with communication function and easy PLC connection! CT 6. Letter's height is 8.7 mm A large LCD panel is used, with a highly legible 8.7 mm letter’s height. Eco-COUNT METER Eco-HOUR METER Building 7. Conform to CE marking (EMC directive) Plant ●Product types (䡺44.5) (䡺1.752) V 3. Economically priced 4. Compact size doesn't take up space (DIN 24 x 48) Easy to install even in cramped spaces. Eco-POWER METER KW4S MODE Commercial CT type 5. Two installation methods available (Separate models) 2. Built-in battery Dimensions Display: Integrated electrical energy, Voltage, Current and Electricity charge Dedicated CT type 1. Easy to install on existing machinery The built-in battery allows the units to be installed anywhere. ●Eco-POWER METER KW4S Current transformer KC2S Eco-COUNT METER/KE2S Eco-HOUR METER Shrink-wrapping machine KW4S Eco-POWER METER Only used for AKW4111, AKW4211 Dedicated current transformer (CT) Data collection software for Eco-POWER METER Power line Rated input Phase and wire system Eco-POWER METER Main unit Simple Watt-Hour Meter Adopts the RS485 for communication specification. This allows you to log data (integrated electrical energy, voltage, and current) from up to 99 units on a PC and PLC. ●Product types Product name Eco-POWER METER (䡺44.5) (䡺1.752) kWh KC2S Eco-COUNT METER Product Name A Eco-COUNT METER main 73 2.874 81.9 3.224 Intermediate power unit*1 Installation type Installation frame type*2 One-touch installation type Front reset Measurement count range Available 0 to 99999999 Installation type Installation frame type*2 One-touch installation type Front reset Measurement count range Available 0 to 99999.9h cable*3 Part No. AKC2421 AKC2621 AKE2811 Air conditioner PC Line process Lights Elevator Constant-temperature oven KE2S Eco-HOUR METER Types and Specifications Product Name ●Types Eco-HOUR METER main Current Changes Communication protocol Only dedicated protocol Dedicated protocol and MEWTOCOL Station number setting 1 to 31 1 to 99 (Note) Communication format setting Setting start → Communication format change Setting start → Protocol switch (dedicated or MEWTOCOL) → Communication format change Instruction Manual — Above content and communication procedure added. unit*1 Intermediate power cable*3 Features added Notes: 1. Eco-HOUR METER (AKE2421/AKE2621) is a product package consisting of the main unit, an exclusive use current transformer (CT), and trunk cable. 2. Only the installation frame installation type includes rubber gasket and installation frame. 3. The maximum allowable current of the intermediate power cable is 15 A. Part No. AKE2421 AKE2621 AKE2811 Eco-3 Brothers Change Note: You must use 1 to 31 when selecting the dedicated protocol (Eco-POWER METER data collection software: AKW4805). ●Communication specifications Interface Protocol Isolation status No. of connected units Transmission distance Transmission speed (Baud rate) Data length Transmission Parity data format Stop bit Communication method Synchronous method Terminating resistor Conforming to RS485 Our method Isolated with internal circuit 99 units* 1,200m 2,400, 4,800, 9,600, 19,200 bps (In each setting mode, settings can be made with front panel keys.) 7-bit/8-bit (In each setting mode, settings can be made with front panel keys.) Not available/Odd/Even (In each setting mode, settings can be made with front panel keys.) 1 bit (Fix) Half duplex Start-stop synchronous method Approx. 120Ω (internal) For maintenance and Integrated Electricity electrical Voltage Current charge control in applications energy Keeping a watchful eye. involving energy saving and environmental protection ●MEWTOCOL-COM commands The Eco-POWER METER supports five commands. RD: Data area read command WD: Data area write command MD: Monitor data save and save reset command MG: Monitor execute command Eco-POWER METER Eco-COUNT METER Eco-HOUR METER RT: Status read command Eco-POWER METER KW4S ARCT1B247E ’05.1 *We recommend the SI-35 of Lineeye Co., Ltd., for the RS485 converter on the PC side. (When using SI-35, FP2-CB485 (for FP2-MCU), FPΣ (COM3 and COM4) or FP-e, the maximum number you can connect is 99. When using with devices other than these, the maximum number will be limited to 31.) http://www.nais-e.com/ 02/2006 Panasonic...the new name for Matsushita Electric Works, Ltd.