Download TX29U -Wireless 915 MHz Temperature Transmitter

Transcript
1.
2.
3.
TX29U -Wireless 915 MHz Temperature Transmitter
The TX-29U temperature transmitter measures the outdoor temperature and
transfers the data to the temperature station.
4.
5.
User shall remove all the batteries from the temperature station and
transmitters and wait 60 seconds if setting has been done with one
transmitter before.
Insert the batteries to the first transmitter.
Within 2 minutes of powering up the first transmitter, insert the batteries
to the Temperature Station. Once the batteries are in place, all
segments of the LCD will light up briefly. Following the indoor
temperature and the time as 12:00 will be displayed. If they are not
shown in LCD after 60 seconds, remove the batteries and wait for at
least 60 seconds before reinserting them.
The outdoor temperature from the first transmitter (channel 1) should
then be displayed on the Temperature station. Also, the signal reception
icon will be displayed. If this does not happen after 5 minutes, the
batteries will need to be removed from both units and reset from step 1.
Insert the batteries to the second transmitter as soon as the outdoor
temperature readings from the first transmitter are displayed on the
temperature station.
Note:
User shall insert the batteries into the second transmitter within 45 seconds of
reception of the first transmitter.
6.
INVENTORY OF CONTENTS
1.
2.
3.
7.
One TX29U Temperature transmitter
Mounting hardware
Instruction manual and warranty card.
ADDITIONAL EQUIPMENT (not included)
•
Two fresh AA, IEC LR6, 1.5V Alkaline batteries.
The outdoor temperature from the second transmitter and the "channel
2" icon should then be displayed on the Temperature station. If this
does not happen after 5 minute, the batteries will need to be removed
from all the units and reset from step 1.
Insert the batteries to the third transmitter as soon as the "channel 2"
icon and outdoor data are displayed on the temperature station. Then
within 5 minutes, the channel 3 outdoor data from the third transmitter
will be displayed and the channel icon will shift back to "1" once the third
transmitter is successfully received. If this is not happen, user shall
restart the setting up from step 1.
Note: User shall insert the batteries into the third transmitter within 45 seconds
of reception of the second transmitter.
IMPORTANT NOTES ON SETUP & OPERATION
•
The temperature transmitter should be placed in a dry, shaded area.
Avoid direct sun, as that will cause incorrect readings.
•
Fog and mist will not harm your temperature transmitter but direct rain
must be avoided.
•
The temperature transmitter has a range of 330 feet (100 m). Keep in
mind that the 330 feet is in open air with no obstructions and that radio
waves DO NOT curve around objects. Actual transmission range will vary
depending on what is in the path of the signal. Each obstruction (roof,
walls, floors, ceilings, thick trees, etc.) will effectively cut signal range in
half.
8.
In order to ensure sufficient 915 MHz transmission however, this should
under good conditions be a distance no more than 330 feet (100 m)
between the final position of the Temperature Station and the
transmitter
IMPORTANT:
Transmission problems will arise if the setting for additional sensors is not
followed as described above. Should transmission problems occur, it is
necessary to remove the batteries from all units and start again the set-up from
step 1.
BATTERY INSTALLATION
Example: A wireless weather/ temperature station with a 330 feet (100 m)
range is mounted on an interior wall, so that the signal has to pass
through one interior wall, one exterior wall, and across the 10 feet (3 m)
width of the room between the 2 walls. The first wall will reduce the range
to 165 feet (50 m), and the second wall will reduce the range to 87 feet
(26.5 m). Factoring in the 10 foot room, this leaves a maximum of 77 feet
(23.5 m) of remaining signal range.
Temperature Station
1.
Lift up the battery compartment cover.
2.
Observing the correct polarity install 2 AA, Alkaline batteries.
The batteries will fit tightly (to avoid start-up problems make sure they do
not spring free).
3.
Replace compartment cover.
Remote Temperature transmitter
1.
Remove the battery cover by sliding the cover down.
2.
Observing the correct polarity install 2 AA, Alkaline batteries. The
batteries will fit tightly (to avoid start-up problems make sure they do not
spring free).
3.
Replace the battery cover by sliding upwards. Be sure battery cover is on
securely.
This allowance is typically enough for a frame wall with non-metallic
siding; however certain materials can reduce range even further. Metal
siding, stucco, and some types of glass can reduce signal range by as
much as ¾ or more, compared to the ½ reduction typical of most
obstructions. It is possible to receive a signal through these materials,
however maximum range will be much less due to their tendency to
absorb or reflect a much larger portion of the sensor’s signal.
•
•
Note:
•
The Temperature transmitter transmits a signal about every 4.5 seconds.
After the batteries have been installed, the indoor temperature station will
search for the signal for a duration of few minutes. If there is no
temperature reading in the OUTDOOR LCD after 5 minutes, user shall
make sure the units are within range of each other, or repeat the battery
installation procedure.
If a button is pressed before the indoor temperature station receives the
signal from the Temperature transmitter, you will need to follow the battery
installation procedure again.
•
If the signal reception is not successful on the first frequency of 915MHz
for 45 seconds, the frequency is changed to 920MHz and the learning is
tried for another 45 seconds. If it is still not successful the reception is
tried for 45 seconds on 910MHz. This will also be done during resynchronization.
Detailed Set up procedures of the Temperature Station and the
Transmitter refer to the main operation manual of WS-9021U or 9640U.
MOUNTING
THE TEMPERATURE TRANSMITTER
The Temperature transmitter can be mounted onto a wall with the use of screws
SETTING UP
MOUNTING WITH SCREWS
When one transmitter is to be used
1.
First, insert the batteries to the temperature transmitter (see “Battery
Installation” below).
2.
Within 2 minutes of powering up the transmitter, insert the batteries to
the Temperature Station (see “Battery Installation” below). Once the
batteries are in place, all segments of the LCD will light up briefly.
Following the indoor temperature and the time as 12:00 will be
displayed. If they are not shown in LCD after 60 seconds, remove the
batteries and wait for at least 60 seconds before reinserting them. Once
the indoor data is displayed user may proceed to the next step.
3.
After the batteries are inserted, the Temperature Station will start
receiving data signal from the transmitter. The outdoor temperature
should then be displayed on the Temperature station. If this does not
happen after 5 minutes, the batteries will need to be removed from both
units and reset from step 1.
4.
In order to ensure sufficient 915 MHz transmission however, there
should be a distance of no more than 330 feet (100 meters) between the
final position of the Temperature Station and the transmitter.
1.
2.
3.
4.
5.
Adding additional remote transmitters (using more than 1 transmitter)
1
Remove the mounting bracket from the Temperature transmitter.
Place the mounting bracket over the desired location.
Through the two screw holes of the bracket, mark the mounting surface
with a pencil.
Screw mounting bracket onto the mounting surface. Ensure that the
screws are tight against the bracket.
Insert the Temperature transmitter into the bracket.
the cost of installation or removal from a fixed installation, normal set-up or
adjustments, claims based on misrepresentation by the seller or performance
variations resulting from installation-related circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR
INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR
DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF
THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL
PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A
TOY. KEEP OUT OF CHILDREN’S REACH.
Table standing
With the mounting bracket installed at the bottom, the transmitter can be placed
on any flat surface.
This warranty gives you specific legal rights. You may also have other rights
specific to your State. Some States do no allow the exclusion of consequential
or incidental damages therefore the above exclusion of limitation may not apply
to you.
For warranty work, technical support, or information contact:
Note:
Before permanently fixing the remote temperature sensor wall base, place all
units in the desired locations to check that the outdoor temperature readings
are receivable. In event that the signal is not received, relocate the remote
temperature sensor or move them slightly as this may help the signal reception.
La Crosse Technology, Ltd
2817 Losey Blvd. S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
MAINTENANCE AND CARE
• Extreme temperatures, vibration, and shock should be avoided to prevent
damage to the units.
• Clean displays and units with a soft, damp cloth. Do not use solvents or
scouring agents; they may mark the displays and casings.
• Do not submerge in water.
• Immediately remove all low powered batteries to avoid leakage and damage.
• Opening the casings invalidates the warranty. Do not try to repair the unit.
Contact La Crosse Technology for repairs.
e-mail:
[email protected]
(warranty work)
[email protected]
(information on other products)
web:
www.lacrossetechnology.com
SPECIFICATIONS
All rights reserved. This handbook must not be reproduced in any form, even in
excerpts, or duplicated or processed using electronic, mechanical or chemical
procedures without written permission of the publisher.
Note:
Detailed Set up procedures of the Temperature Station and the transmitter
refers to the main operation manual of WS-9021U or 9640U.
This handbook may contain mistakes and printing errors. The information in
this handbook is regularly checked and corrections made in the next issue. We
accept no liability for technical mistakes or printing errors, or their
consequences.
All trademarks and patents are acknowledged.
Data measuring range:
Outdoor temperature:
-39.8 °F to 139.8°F with 0.2°F resolution
(-39.8°C to 59.9°C with 0.1°C resolution)
“OFL” displayed if outside this range
Transmission range:
330 feet (100 m) in open space
Power Supply:
Temperature
2 x AA, IEC LR6, 1.5V
transmitter :
Battery life cycle:
Approximately 24 months
Recommended
Alkaline
battery type:
Dimensions (H x W x D):
Temperature
1.50 x 0.83 x 5.05 in
transmitter
(38.2 x 21.2 x 128.3 mm)
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this product
against manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only on
products purchased and used in North America and only to the original
purchaser of this product. To receive warranty service, the purchaser must
contact La Crosse Technology, Ltd for problem determination and service
procedures. Warranty service can only be performed by a La Crosse
Technology, Ltd authorized service center. The original dated bill of sale must
be presented upon request as proof of purchase to La Crosse Technology, Ltd
or La Crosse Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product, at our option and
at no charge as stipulated herein, with new or reconditioned parts or products if
found to be defective during the limited warranty period specified above. All
replaced parts and products become the property of La Crosse Technology, Ltd
and must be returned to La Crosse Technology, Ltd. Replacement parts and
products assume the remaining original warranty, or ninety (90) days,
whichever is longer. La Crosse Technology, Ltd will pay all expenses for labor
and materials for all repairs covered by this warranty. If necessary repairs are
not covered by this warranty, or if a product is examined which is not in need or
repair, you will be charged for the repairs or examination. The owner must pay
any shipping charges incurred in getting your La Crosse Technology, Ltd
product to a La Crosse Technology, Ltd authorized service center. La Crosse
Technology, Ltd will pay ground return shipping charges to the owner of the
product to a USA address only.
Your La Crosse Technology, Ltd warranty covers all defects in material and
workmanship with the following specified exceptions: (1) damage caused by
accident, unreasonable use or neglect (including the lack of reasonable and
necessary maintenance); (2) damage occurring during shipment (claims must
be presented to the carrier); (3) damage to, or deterioration of, any accessory or
decorative surface; (4) damage resulting from failure to follow instructions
contained in your owner’s manual; (5) damage resulting from the performance
of repairs or alterations by someone other than an authorized La Crosse
Technology, Ltd authorized service center; (6) units used for other than home
use (7) applications and uses that this product was not intended or (8) the
products inability to receive a signal due to any source of interference.. This
warranty covers only actual defects within the product itself, and does not cover
2