Download Model 2600-KIT Screw Terminal Connector Kit

Transcript
Model 2600-KIT
Screw Terminal Connector Kit
Keithley Instruments, Inc.
28775 Aurora Road
Cleveland, Ohio 44139
(440) 248-0400
www.keithley.com
Introduction
This document contains information on the Model 2600-KIT Screw Terminal Connector Kit. The kit contains a cable housing and an inverted plug. Use this kit to cable Category I SMU output connections on the
rear panel of a Model 260x Series SourceMeter® Instrument to DUTs (Devices Under Test).
WARNING Maximum floating (common mode) voltage for an SMU is 250V. Exceeding this level could damage the instrument and create a shock hazard.
Using an external source to float an SMU could create a shock hazard in
the test circuit. A shock hazard exists whenever >42V peak is present in
the test circuit.
NOTE
If applicable, remove terminal block(s) before using the Model 2600-KIT.
The Model 2602 can use two terminal blocks (one for each SMU channel),
the Model 2601 has one terminal block for the single SMU.
A terminal block can be removed from the rear panel by loosening the two
captive retaining screws and pulling it off the rear panel.
Connector description
The inverted plug secures cables to pins for a quick connection to the rear panel SMU connector. Refer to
Table 1 for plug specifications.
Table 1
Plug specifications
Characteristic
Insulation Material Group
Specification
I
Nominal Current/Cross Section
12A/2.5mm2
Maximum Load Current/Cross Section
12A/2.5mm2
Connection Capacity
24–12AWG
UL and CSA Approval Data:
Nominal Voltage
250V
Current
12A
Conductor Sizes
24–12AWG
PA-907 Rev. A / 04-05
The green cable housing provides for cable diameters of 6–13.5mm. Marker strips and a transparent label
carrier are included. Use supplimentary insulation as applicable.
To cable a connector (refer to Figure 1):
1.
2.
3.
4.
5.
Determine wiring requirements and pinouts (see Table 2).
Split cable housing into upper and lower halves.
Loosen strain relief screws.
Thread wire and cabling into housing through strain relief.
Connect wires to the inverted plug. Make connections to the applicable screw terminals
for the determined wiring requirements.
6. Snap housing halves together.
7. Secure cable with strain relief.
Figure 1
Connector assembly
Top View
Side View
Cabling
Strain relief
Screw
Cable housing
Screw terminals
8
Inverted plug
2
7
6
5
4
3
2
1
Table 2
Connector pinouts
Pin No.
Connector
1
LO
2
Sense LO
3
G
4
HI
5
G
6
G
7
G
8
Sense HI
Figure
87654321
Connection
Refer to Figure 2 for a typical instrument connector location. Refer to the specific instrument’s user manual
for additional connection information.
WARNING Do not exceed the voltage rating for the wiring used or for the
Model 260x. Make sure connections at both ends do not exceed the rated specifications.
Failure to follow this warning may result in injury from electrical shock
as well as damage to the equipment.
Figure 2
Typical instrument connector
Category I SMU connection
WARNING:NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
UL
C
S G
HI
CHANNEL A
US
LISTED
SourceMeter
4ZA4
G G HI G S LO
LO
!
CAT I
CHANNEL B
!
S
CAT I
LO LO G HI G G
!
DIGITAL I/O
LINE FUSE
SLOWBLOW
3.15A, 250V
RS-232
S
G HI
LINE RATING
100-240VAC
50, 60Hz
240VA MAX.
MADE IN
U.S.A.
IEEE-488
(CHANGE IEEE ADDRESS
WITH FRONT PANEL MENU)
!
TSP-Link
R
CAUTION:FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
3