Download Model 2600-KIT Screw Terminal Connector Kit
Transcript
Model 2600-KIT Screw Terminal Connector Kit Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 www.keithley.com Introduction This document contains information on the Model 2600-KIT Screw Terminal Connector Kit. The kit contains a cable housing and an inverted plug. Use this kit to cable Category I SMU output connections on the rear panel of a Model 260x Series SourceMeter® Instrument to DUTs (Devices Under Test). WARNING Maximum floating (common mode) voltage for an SMU is 250V. Exceeding this level could damage the instrument and create a shock hazard. Using an external source to float an SMU could create a shock hazard in the test circuit. A shock hazard exists whenever >42V peak is present in the test circuit. NOTE If applicable, remove terminal block(s) before using the Model 2600-KIT. The Model 2602 can use two terminal blocks (one for each SMU channel), the Model 2601 has one terminal block for the single SMU. A terminal block can be removed from the rear panel by loosening the two captive retaining screws and pulling it off the rear panel. Connector description The inverted plug secures cables to pins for a quick connection to the rear panel SMU connector. Refer to Table 1 for plug specifications. Table 1 Plug specifications Characteristic Insulation Material Group Specification I Nominal Current/Cross Section 12A/2.5mm2 Maximum Load Current/Cross Section 12A/2.5mm2 Connection Capacity 24–12AWG UL and CSA Approval Data: Nominal Voltage 250V Current 12A Conductor Sizes 24–12AWG PA-907 Rev. A / 04-05 The green cable housing provides for cable diameters of 6–13.5mm. Marker strips and a transparent label carrier are included. Use supplimentary insulation as applicable. To cable a connector (refer to Figure 1): 1. 2. 3. 4. 5. Determine wiring requirements and pinouts (see Table 2). Split cable housing into upper and lower halves. Loosen strain relief screws. Thread wire and cabling into housing through strain relief. Connect wires to the inverted plug. Make connections to the applicable screw terminals for the determined wiring requirements. 6. Snap housing halves together. 7. Secure cable with strain relief. Figure 1 Connector assembly Top View Side View Cabling Strain relief Screw Cable housing Screw terminals 8 Inverted plug 2 7 6 5 4 3 2 1 Table 2 Connector pinouts Pin No. Connector 1 LO 2 Sense LO 3 G 4 HI 5 G 6 G 7 G 8 Sense HI Figure 87654321 Connection Refer to Figure 2 for a typical instrument connector location. Refer to the specific instrument’s user manual for additional connection information. WARNING Do not exceed the voltage rating for the wiring used or for the Model 260x. Make sure connections at both ends do not exceed the rated specifications. Failure to follow this warning may result in injury from electrical shock as well as damage to the equipment. Figure 2 Typical instrument connector Category I SMU connection WARNING:NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY. UL C S G HI CHANNEL A US LISTED SourceMeter 4ZA4 G G HI G S LO LO ! CAT I CHANNEL B ! S CAT I LO LO G HI G G ! DIGITAL I/O LINE FUSE SLOWBLOW 3.15A, 250V RS-232 S G HI LINE RATING 100-240VAC 50, 60Hz 240VA MAX. MADE IN U.S.A. IEEE-488 (CHANGE IEEE ADDRESS WITH FRONT PANEL MENU) ! TSP-Link R CAUTION:FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING. 3