TrangoLINK ApexPlus
6-40 GHz
All Outdoor High Capacity Point to Point Microwave Backhaul System
User Manual
LT‐9031 Revision 3.0 Notice This document contains information that is confidential and proprietary to Trango Systems, Inc. No part of the content of this publication may be reproduced, modified, dused, copied, disclosed, conveyed, or distributed to any party in any manner whatsoever without prior written authorization from Trango Systems, Inc. This document is provided as is, without warranty of any kind. Trademarks Trango Systems®, TrangoLINK®, and TrangoLINK Giga® are registered trademarks of Trango Systems, Inc. Other names mentioned in this publication are owned by their respective holders. Statement of Conditions The information contained in this document is subject to change without notice. Trango Systems, Inc. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it. Information to User Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s authority to operate the equipment and the warranty for such equipment. Trango Systems, Inc. 14118 Stowe Drive, Suite B Poway, CA 92064 Tel.: +1 (858) 391‐0010 Fax: +1 (858) 391‐0020 Copyright © 2011 by Trango Systems, Inc. All rights reserved. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 2 Contents Tables..................................................................................................................8 Figures ................................................................................................................9 Revision History.............................................................................................11 Preface ..............................................................................................................12 Reference conventions ................................................................................13 Warranty Information ....................................................................................13 Contacting Trango Technical Support.....................................................13 Standards Compliance .................................................................................14 1.0 Product Description............................................................................15 Overview.......................................................................................................................... 15 Ports and Indicators ....................................................................................................... 17 Antenna Connection ...................................................................................................... 20 Remote Mounting ........................................................................................................... 20 Combiners for Antenna Sharing .................................................................................. 20 Power Supply.................................................................................................................. 20 Direct Power Option....................................................................................................... 21 Power Over Ethernet (PoE) Option ............................................................................. 21 Key Features................................................................................................................... 22 Patent Pending Design............................................................................................ 22 Traffic Capacity......................................................................................................... 22 Industry Leading System Gain ............................................................................... 22 Full Licensed band frequency and T/R spacing support.................................... 24 Channel Sizes from 3.5 MHz to 80 MHz .............................................................. 24 Adaptive Coding and Modulation........................................................................... 25 Link Protection through 1+1 Hot Standby ............................................................ 26 2.0 Wireless Operation Detail..................................................................27 Channel Bandwidth........................................................................................................ 27 Modulation ....................................................................................................................... 27 Mean Squared Error (MSE).......................................................................................... 27 Adaptive Coding and Modulation (ACM) .................................................................... 29 Wireless Link Capacity .................................................................................................. 32 Automatic Transmit Power Control (ATPC) ............................................................... 33 ATPC Max Power & Step Size..................................................................................... 33 Transmitter Maximum Power Output .......................................................................... 33 Transmitter Minimum Power output ............................................................................ 34 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 3 Receiver Maximum Input .............................................................................................. 35 3.0 Network Operation Detail ..................................................................36 1+0 Non-Protected Link Configuration ....................................................................... 36 1+1 Hot Standby Protected Link Configuration ......................................................... 37 Hardware triggered failover .................................................................................... 38 Software triggered failover...................................................................................... 39 User triggered (manual) failover ............................................................................ 39 Rapid Port Shutdown (RPS)......................................................................................... 40 VLAN Tagging ................................................................................................................ 40 Port Mapping (802.1q)................................................................................................... 41 Quality of Service (QoS) (802.1p and Diffserv) ......................................................... 41 Port Priority...................................................................................................................... 42 Port Rate Limiting (Ingress).......................................................................................... 43 Egress Margin................................................................................................................. 43 4.0 Link Management ................................................................................44 Overview.......................................................................................................................... 44 Graphical User Interface (Web Browser) ................................................................... 45 Command Line Interface (CLI) using SSH, Telnet or Console ............................... 48 Changing Password................................................................................................. 50 Console Port ............................................................................................................. 50 Simple Network Management Protocol (SNMP) ....................................................... 51 Common Objects for Monitoring and Control ...................................................... 52 Firmware Upgrade ......................................................................................................... 53 Upgrade Procedure -TFTP ..................................................................................... 54 Upgrade Procedure -FTP........................................................................................ 56 Capacity Upgrades ........................................................................................................ 58 5.0 Link Planning ........................................................................................59 Frequency/Path Planning.............................................................................................. 59 Site Selection .................................................................................................................. 59 Licensing.......................................................................................................................... 59 6.0 Installation .............................................................................................60 Safety ............................................................................................................................... 60 Installation Process........................................................................................................ 63 Preparing for Installation ............................................................................................... 63 Tools................................................................................................................................. 63 Power Supply.................................................................................................................. 64 Grounding Diagram........................................................................................................ 66 PoE Based Installation .................................................................................................. 67 PoE Based Installation (1+0)........................................................................................ 69 PoE Based Installation (1+1 Hot Standby)................................................................. 72 Direct Power Based Installation (1+0) ........................................................................ 73 Direct Power Based Installation (1+1 Hot Standby) ................................................. 73 ApexPlus ODU Installation on Antenna...................................................................... 74 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 4 Cable Installation............................................................................................................ 76 Antenna Installation ....................................................................................................... 80 7.0 Link Configuration...............................................................................81 Web Based Configuration ............................................................................................. 82 Web Based 1+0 Setup ............................................................................................ 82 Web Based 1+1 Setup ............................................................................................ 87 Adaptive Coding and Modulation (ACM) (Optional) ........................................... 88 Automatic Transmit Power Control (ATPC) (Optional) ...................................... 89 Command Line Interface (CLI) Based Configuration ............................................... 90 CLI Based 1+0 Configuration ................................................................................. 90 CLI Based 1+1 Hot Standby Configuration.......................................................... 96 Antenna Alignment......................................................................................................... 97 CLI Common Task Reference...................................................................................... 99 Setting up the In-Band-Management (IBM) ......................................................... 99 Capacity License Activation.................................................................................. 101 Automatic Transmit Power Control (ATPC) Configuration (optional) ............ 101 Check Ethernet and RF port Statistics................................................................ 102 Enable Traps (Optional) ........................................................................................ 104 8.0 Troubleshooting................................................................................ 106 Appendix A – Command Line Interface Reference ........................... 109 Command Keying Overview ....................................................................................... 109 Key Functions ......................................................................................................... 109 Different Node Levels .................................................................................................. 110 View Node ............................................................................................................... 110 Config Node ............................................................................................................ 112 Debug Node ............................................................................................................ 117 Individual Command Details....................................................................................... 118 acm ........................................................................................................................... 118 atpc ........................................................................................................................... 119 ber............................................................................................................................. 120 bootimage................................................................................................................ 120 config........................................................................................................................ 121 cos ............................................................................................................................ 122 datapath (future) ..................................................................................................... 123 datapattern .............................................................................................................. 124 date........................................................................................................................... 124 debug ....................................................................................................................... 124 default_opmode...................................................................................................... 125 diagnostic ................................................................................................................ 126 egress_margin ........................................................................................................ 126 exit ............................................................................................................................ 127 failover...................................................................................................................... 127 freq............................................................................................................................ 128 freq_duplex.............................................................................................................. 129 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 5 ftp .............................................................................................................................. 129 guard_time .............................................................................................................. 131 help / ? ..................................................................................................................... 132 httpd.......................................................................................................................... 132 ibm ............................................................................................................................ 133 ipconfig..................................................................................................................... 134 license ...................................................................................................................... 134 link_history............................................................................................................... 135 linktest ...................................................................................................................... 135 loglevel ..................................................................................................................... 136 loopback .................................................................................................................. 136 model........................................................................................................................ 137 mse ........................................................................................................................... 138 odupower ................................................................................................................. 139 opmode .................................................................................................................... 139 passwd ..................................................................................................................... 140 port............................................................................................................................ 140 power........................................................................................................................ 141 prompt ...................................................................................................................... 142 qos ............................................................................................................................ 142 reboot ....................................................................................................................... 143 reload ....................................................................................................................... 143 remark ...................................................................................................................... 144 reset.......................................................................................................................... 144 rps ............................................................................................................................. 145 rssi ............................................................................................................................ 146 show ......................................................................................................................... 146 siglevel ..................................................................................................................... 147 smart_mode ............................................................................................................ 148 snmpd....................................................................................................................... 148 speed........................................................................................................................ 149 status........................................................................................................................ 150 sync .......................................................................................................................... 150 sync_status ............................................................................................................. 151 sysinfo ...................................................................................................................... 152 syslog ....................................................................................................................... 152 targetrssi .................................................................................................................. 153 tdm............................................................................................................................ 153 telnetd....................................................................................................................... 154 temp.......................................................................................................................... 154 tftpd........................................................................................................................... 155 threshold .................................................................................................................. 155 trap............................................................................................................................ 157 uptime....................................................................................................................... 157 utype......................................................................................................................... 158 utype_switch ........................................................................................................... 159 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 6 version...................................................................................................................... 160 voltage...................................................................................................................... 160 web_refresh_rate ................................................................................................... 160 Appendix B – Product Specifications ................................................... 162 Dimensions and Weight ........................................................................................ 162 Environmental ......................................................................................................... 162 Emissions ................................................................................................................ 162 Reliability ................................................................................................................. 163 Electromagnetic Compliance................................................................................ 163 Wireless Compliance ............................................................................................. 163 Wireless Parameters ............................................................................................. 164 Transmitter Power.................................................................................................. 164 1+1 Hot Standby Link Protection ......................................................................... 166 Specification............................................................................................................ 166 Power ....................................................................................................................... 166 User Interfaces ....................................................................................................... 166 Ethernet Parameters.............................................................................................. 167 T1/E1 Parameters .................................................................................................. 167 Appendix C – Cable Wiring ...................................................................... 168 Ethernet Cabling........................................................................................................... 168 Console Port Cabling................................................................................................... 169 Appendix D – MIB OID Listing................................................................. 170 Appendix E – Part Numbers..................................................................... 176 ApexPlus Sub-bands/Tuning Ranges ....................................................................... 176 Accessories ................................................................................................................... 188 Appendix F – Link Install and Commissioning Logs ........................ 189 Appendix G – Declaration of Conformity ............................................. 200 Glossary ........................................................................................................ 201 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 7 Tables Table 1: TrangoLINK® ApexPlus part numbers............................................................... 12 Table 2 Combiner Cross Reference.................................................................................. 20 Table 3 ApexPlus Band and T/R Spacing Options ......................................................... 24 Table 4 MSE Expected and Maximum Values ................................................................ 28 Table 5 ACM Threshold Table ........................................................................................... 30 Table 6 Max Link Capacity (Mbps) for non-ACM Speed Settings................................ 32 Table 7 Maximum Set Power Levels by Band and Modulation .................................... 34 Table 8 Minimum TX set power by band.......................................................................... 34 Table 9 Max Receive Level Input ...................................................................................... 35 Table 10 Failover Events .................................................................................................... 38 Table 11 Default Login Passwords.................................................................................... 45 Table 12 RSSI to Voltage Conversion .............................................................................. 98 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 8 Figures Figure 1 OMU Functional Block Diagram......................................................................... 15 Figure 2 ODU Functional Block Diagram ......................................................................... 16 Figure 3 ApexPlus Ports and indicators ........................................................................... 17 Figure 4 Polarization Indicator ........................................................................................... 19 Figure 5 Product Label ........................................................................................................ 19 Figure 6 LDPC vs. Reed-Solomon Coding ...................................................................... 23 Figure 7 Adaptive Coding and Modulation (ACM) .......................................................... 25 Figure 8 1+0 Setup .............................................................................................................. 36 Figure 9 1+1 Setup .............................................................................................................. 37 Figure 10 Web Browser Login............................................................................................ 45 Figure 11 System Info Page ............................................................................................... 46 Figure 12 Console Port Setting.......................................................................................... 51 Figure 13: Windows Start & Telnet ................................................................................... 54 Figure 14 Capacity Upgrade – Web.................................................................................. 58 Figure 15- 48 VDC Power Connector using Coaxial Cable and 16 AWG Cable....... 65 Figure 16 PoE Based Grounding Diagram ...................................................................... 66 Figure 17 POE-GIGE-48 ..................................................................................................... 67 Figure 18 POE-GIGE-48 Internal wiring ........................................................................... 68 Figure 19 1+0 / IBM PoE Wiring ........................................................................................ 69 Figure 20 1+0 / OBM PoE Wiring ...................................................................................... 70 Figure 21 1+0 PoE Redundant Wiring .............................................................................. 71 Figure 22 Direct Power Wiring ........................................................................................... 73 Figure 23 Antenna to ApexPlus Slip Fit Waveguide connection .................................. 74 Figure 24 Polarization Indicator ......................................................................................... 75 Figure 25 Latches ................................................................................................................ 75 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 9 Figure 26 Port Sealing Components ................................................................................. 76 Figure 27 STP Cables installed on Unit............................................................................ 76 Figure 28 Detail of the Stainless Steel Thumbscrew...................................................... 77 Figure 29 Strain Relief Exploded View ............................................................................. 77 Figure 30 Strain Relief Installed......................................................................................... 78 Figure 31 Ground Lug on OMU ......................................................................................... 78 Figure 32 Web Interface Login........................................................................................... 82 Figure 33 Web Login with Password ................................................................................ 82 Figure 34 System Status- Version Page .......................................................................... 83 Figure 35 Link Setup Page ................................................................................................. 86 Figure 36 Failover Mode Set .............................................................................................. 87 Figure 37 ACM Setup .......................................................................................................... 88 Figure 38 ATPC Setup/ RPS /Telnetd/ tftpd .................................................................... 89 Figure 39 BNC Connector for RSSI Voltage.................................................................... 97 Figure 40 EIA/TIA 568A Straight through....................................................................... 168 Figure 41 EIA/TIA 568B Cross-Over............................................................................... 168 Figure 42: ApexPlus Serial Cable Pin-Out ..................................................................... 169 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 10 Revision History Revision
1.0
3.0
Revision Date
4 Apr 2011
5 May 2012
Description
Initial Release
Update to reflect the following feature changes in SW V3.0 plus bug
fixes (see release note for bug fixes)
Allow IBM without a VLAN on AP-OMU-1 HWID 2 models
Custom Speed Profile Support
Support for 5. 8.33, 12.5, and 25 MHz channels sizes
Diffserv (DSCP) and weighted QoS on a per port basis
Individual Ethernet Port utilization Statistics
SNMP OID harmonization with GigaPlus 3.0
Remote Link status reporting
Two level access web interface (view/ config)
Web look and feel changes
Auto loopback diagnostic
Add “link down” threshold parameter
Link Status recording and comparing diagnostic
Reload/reboot in x seconds
Linktest added to web
Web page refresh rate control
BER calculation improvement
Eth port loopback diagnostic
Remove limitation of turning opmode off for a freq change
Add note regarding hardware compatibility by revision
Update Table 3 to add new 7 and 13 GHz TR s
Add note about PoE Voltage range and grounding
Updated Figure 22 Direct Power Input
Login via web config mode
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 11 Preface This manual covers the configuration and installation of the TrangoLINK® ApexPlus licensed microwave backhaul system, This document is intended to instruct and assist personnel in the operation, installation and maintenance of the Trangolink® ApexPlus microwave backhaul system and related accessories shown in Table 1. It is recommended that all personnel engaged in such activities be properly trained. Trango Systems disclaims all liability whatsoever, implied or express, for any risk of damage, loss or reduction in system performance arising directly or indirectly out of the failure of the customer, or anyone acting on the customer's behalf, to abide by the instructions, system parameters, or recommendations made in this document. Part Number
TLAP1-XX-YYYY-Z
TLAP2-XX-YYYY-Z
AP1-XX-YYYY-ZZ
AP2-XX-YYYY-ZZ
PSUPPLY-DT-48
PSUPPLY-1U-48
POE-GIGE-48
CBLDAT-4
CBLDAT-RIU4
CBLDAT-RSSI
AP-KEY-1
AP-KEY-2
AP-KEY-3
SFP-GigE-C
SFP-GigE-S
SFP-GigE-M
Description
®
TrangoLINK ApexPlus HP system, XXGHz, YYYY Duplex, Subband Z
®
TrangoLINK ApexPlus HP2 system, XXGHz, YYYY Duplex, Subband Z
®
TrangoLINK ApexPlus HP All Outdoor Unit, XXGHz, YYYY Duplex, Subband
ZZ
®
TrangoLINK ApexPlus HP2 All Outdoor Unit,, XXGHz, YYYY Duplex, Subband
ZZ
-48 Volt Universal Desktop Power Supply
-48 Volt Universal Rack mount Power Supply
PoE injector/Surge Suppressor for ApexPlus
Serial Console Cable for ApexPlus
1+1 Hot Standby Cable for ApexPlus
BNC-M to Banana plug cable for RSSI voltage measurement
Software Key to Allow Throughputs up to 200Mbps
Software Key to Allow Throughputs up to 375Mbps
Software Key to Allow Higher Transmit Power for 11-23 GHz on AP1 models
SFP 1000BaseT Copper RJ45
SFP Fiber Single Mode Module
SFP Fiber Multi Mode
Table 1: TrangoLINK® ApexPlus part numbers Specific part numbers for radio unit sub‐bands and band specific accessories such as antennas, combiners and remote mounts can be found in Appendix E. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 12 Reference conventions This document utilizes several conventions. All system command references are shown in bold italics. All references to external publications are shown in bold. Warranty Information TrangoLINK® ApexPlus units purchased from Trango Systems, Inc. are warranted for two years from date of purchase. Please see www.trangosys.com for a complete description of warranty coverage and limitations. Extended warranty protection can be purchased through Trango Sales or Customer Service (+1 858‐391‐0010). Contacting Trango Technical Support Should assistance be required or an RMA be required, you may contact the technical support department using the following methods: Address: Trango Systems, Inc. 14118 Stowe Dr Suite B Poway, CA, 92064 USA Phone: (858) 391‐0010 from 8 am to 5 pm Pacific Standard Time. Email: [email protected] Web: www.trangosys.com Trango Systems, Inc. ApexPlus User Manual Rev 3.0 13 Standards Compliance Federal Communications Commission (FCC) ANSI models of the TrangoLINK® ApexPlus product line have been tested and found to comply with the following FCC standards: CFR47 Part 15 CFR 47 Part 101 Appendix E shows the specific part numbers that have been tested. Federal Communications Commission (FCC) Emission Designators •
•
•
•
•
•
•
•
•
•
5M0D7W for 5 MHz BW rates and all modulations 8M3D7W for 8.33 MHz BW rates and all modulations 10M0D7W for 10 MHz BW rates and all modulations 12M5D7W for 12.5 MHz BW rates and all modulations 20M0D7W for 20 MHz BW rates and all modulations 25M0D7W for 25 MHz BW rates and all modulations 30M0D7W for 27.5/28/30 MHz BW rates and all modulations 40M0D7W for 40 MHz BW rates and all modulations 50M0D7W for 50 MHz BW rates and all modulations 56M0D7W for 55/56/80 MHz BW rates and all modulations European Telecommunications Standards Institute (ETSI) ETSI models of the TrangoLINK® ApexPlus product line have been tested and found to comply with the European Telecommunications Standards: •
EN 302 217‐2‐1 V1.2.1 (2007‐02) •
EN 302 217‐2‐2 V1.2.2 (2007‐04) •
EN 301 489‐1 V1.8.1 (2008‐04) •
EN 301 489‐4 V1.4.1 (2008‐09) •
EN 60950‐1 These standards cover all the essential requirements of Directive 1999/5/EC. Appendix E shows the specific part numbers that have been tested. RoHS Compliance The TrangoLINK® ApexPlus product line complies with the European Union (EU) Directive 2002/95/EC on the Restriction of Hazardous Substances (RoHS). Trango Systems, Inc. ApexPlus User Manual Rev 3.0 14 1.0 Product Description Overview The TrangoLINK® ApexPlus is a high‐performance all outdoor point‐to‐point wireless microwave system designed for Carrier, Enterprise, and Service Provider networks using the 6‐40 GHz licensed spectrum. The system provides a full duplex wireless Layer 2 Ethernet connection with ultra low packet latency and jitter, and supports both 10/100/1000BaseT and Fiber interfaces, as well as T1/E1 interfaces for timing or legacy TDM support. The unique design of the ApexPlus was created to allow the highest performance possible across all standard frequency bands and TR spacings, best heat dissipation for operation in warm climates, and easy sparing options for larger networks. Each unit consists of an Outdoor Modem Unit (OMU) and an Outdoor RF unit (ODU), connected via a single coaxial cable. Figures 1 and 2 show the functional block diagram of the system as they are divided between the OMU and ODU. TDM (T1/E1)
Modem
Ethernet 1
Ethernet 2
Ethernet
Switch
DAC
ADC
TX
(350 MHz)
TX
IQ
RX
IQ
IF Circuitry
RX
(140 MHz)
TX
(5.5 MHz)
-48 VDC
ODU
control
circuit
Power Over
Ethernet
Circuit
CPU Subsystem
NPlexer
Coaxial
Cable
ODU
RX
(10MHz)
-48 VDC
Ethernet 3 (Control)
Relay
OMU
Figure 1 OMU Functional Block Diagram Trango Systems, Inc. ApexPlus User Manual Rev 3.0 15 Control CPU
Power
Amplifier
Transmit
TX
Upconverter
(350 MHz)
OMU
Coaxial
Cable to the
OMU
NPlexer
Local
Oscillator
Waveguide
port
RX
(140 MHz)
Diplexer
Receive
Downconvertor
-48V
Low noise
Amplilfier
Power Supply
ODU
Figure 2 ODU Functional Block Diagram The TrangoLINK® ApexPlus is a Frequency Division Duplex (FDD) radio which can provide low latency of less than 150 microseconds (μs), over 1 million packets per second, and up to 375 Mbps of full duplex capacity. Standard features include Quality‐of‐Service (QoS) traffic prioritization to ensure that critical traffic gets through, Hitless Adaptive Coding and Modulation (ACM) and Adaptive Transmit Power Control (ATPC) to improve performance during weather related signal degradation. ApexPlus supports either direct ‐48 Volt DC power or power over Ethernet using a PoE injector device provided by Trango. The PoE injector has interfaces for Ethernet, T1/E1 traffic and management, as well as support for redundant power supplies. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 16 Ports and Indicators The Figure below shows the various ports on the ApexPlus Unit. 10/100BaseT Mgmt Port + Power (PoE) – Fiber/Copper SFP Data Port Air Vent
10/100/1000Base T Data Port + Power (PoE) – RJ45 Direct Power Port ‐48 VDC + Reset Switch 1+1/Serial Console Connector
Coaxial OMU to ODU Cable Mounting Latch Grounding Lug ‐ ODU RSSI Voltage Port Figure 3 ApexPlus Ports and indicators 10/100/1000BaseT RJ45 Connector ‐ This is the main native Ethernet data port. SFP Port – SFP Port supports a second native 1000BaseT or LC fiber Ethernet connection for traffic. SFP modules are available to support each as follows: a. SFP‐GigE‐C – Copper RJ45 module to support 1000BaseT b. SFP‐GigE‐S – Single Mode Fiber for long haul c. SFP‐GigE‐M– Multimode Fiber for short haul 10/100BaseT RJ45 Connector – For Out of band Web, SNMP, Telnet, and SSH management. Also multiplexed as a native T1/E1 Interface to support TDM traffic when using the PoE Injector PoE‐GigE‐48. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 17 Direct Power Terminal Block – this terminal block supports direct powering of the unit using ‐48 Volt DC power. 1+1 Hot Standby LED – This LED indicates the following conditions related to the 1+1 hot standby operation. 1) A backup unit has been detected (solid). 2) The 1+1 mode is active (blinking). Reset Switch – The Reset switch operates as follows: 1) Hold for more than 2 seconds, but less than 6 seconds, the unit will: a. The IP address will be reset to default to allow access in the event of a forgotten password or IP address. b. The CLI management passwords will be reset to default c. The Web interface passwords will be reset to default. d. The SNMP read/write/trap community strings will be set to defaults. e. The CLI prompt will be reset. 2) Hold for more than 6 seconds: The unit will reset the system configuration to the factory default, but NOT reset the items it (1) above. The unit WILL REBOOT automatically. 1+1/Serial Console Connector – When using 1+1 Hot Standby with a combiner and second identical ApexPlus, cable CBLDAT‐RIU4 is connected between this connector on both units to allow critical timing and communication between the OMU during 1+1 hot standby operation. GoreTM Air Vent – The air vent is present to provide pressure equalization at high altitudes while preventing moisture from entering the unit. No operator interaction is necessary. !
DO NOT TAMPER with the Air Vent. It should not be twisted or removed. Tampering with or damaging the Protective Vent will void the factory warranty. RSSI Voltage BNC‐F Connector – This connector is provided to allow easy antenna alignment when used with a multi‐meter and the CBLDAT‐RSSI cable. The Voltage present on the connector is directly proportional to the Received Signal Strength in the receiver section of the ApexPlus. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 18 OMU to ODU cable– This cable carries the Transmit IF signal, Receive IF signal, supply voltage, and control signaling to the ODU. The cable is sealed using heat shrink to prevent water ingress and should only be changed by Trango factory certified personnel. Mounting Latches – Four latches are provided to allow easy attachment of the ApexPlus to the standard antennas, combiners and remote mounts. Two of the latches have keyholes to allow locking the unit to deter theft and/or secure the unit. Polarization Indicators – The letters “H” and “V” are die cast on the OMU housing perimeter to assist in mounting the ApexPlus to the antenna in the correct polarization. The letter that is at the top will always indicate the antenna polarization being utilized. “H” polarization indicator Figure 4 Polarization Indicator Grounding Lug – OMU – The ground lug provided on the OMU should be connected to the tower/structure leg per the grounding section recommendations. Grounding Lug – ODU ‐ The ground lug provided on the ODU should be connected to the tower/structure leg per the grounding section recommendations. Labels – The Serial numbers and MAC address, along with the regulatory compliance information are shown on the ODU labels attached to the ODU and OMU exterior. Figure 5 Product Label Trango Systems, Inc. ApexPlus User Manual Rev 3.0 19 Antenna Connection The ODU portion of the ApexPlus utilizes a slip fit connection that makes installation simple. The ODUs are all designed to mount to a circular waveguide antenna or combiner with the exception of the 6 GHz models. For 7 to 40 GHz models, simply rotating the ApexPlus will change the antenna polarization being used. A compatibility list of antennas is provided in Appendix E. Remote Mounting When using the ApexPlus with non‐Trango antennas, a Remote Mount plus flex waveguide may be needed. The compatible remote mounts are shown in Appendix E. The waveguide flanges are available for mounting all standard waveguide sizes. Combiners for Antenna Sharing The ApexPlus unit is designed with an easy slip fit interface to the antenna. If desired, two units may be connected to the same antenna for 1+1 hot standby application or to aggregate two channels for more capacity. Trango can provide multiple combiner options based on the customer applications as the table shows below: Table 2 Combiner Cross Reference Appendix E gives detailed information on which specific frequency bands are supported for each type of combiner. Power Supply Trango can provide power supplies for rack mount and desktop applications. The PSUPPLY‐1U‐48 is a rack mount power supply with 6.5 Amp capacity that can support multiple co‐located ApexPlus units. The PSUPPLY‐WM‐48‐L is a wall mount power supply with 1.5 Amp capacity and is only recommended for a single ApexPlus unit. The power supply must be kept in a temperature controlled environment within the operating temp of 0 to 40 deg C. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 20 Direct Power Option The ApexPlus can be direct powered using a ‐48 Volt DC source with a terminal block connection at the unit. The length of the cable varies on the gauge of the wire being used, but in general longer distances can be achieved than using the PoE option since the voltage drop is less. As long as the minimum voltage is maintained at the ApexPlus unit, the system will operate. This option is also preferred for applications using fiber for the data
Power Over Ethernet (PoE) Option When utilized with a POE‐GIGE‐48 PoE injector, the ApexPlus can be powered over the same Cat5e/Cat6 Shielded Twisted Pair (STP) that is used for the Data and in‐band management connection. Surge suppression and provision for redundant power supplies are provided with a single POE‐GIGE‐48 device.
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 21 Key Features Patent Pending Design The ApexPlus is the first all outdoor microwave system to utilize two piece architecture consisting of an outdoor Modem Unit (OMU) and an Outdoor Radio Unit (ODU). This unique design has several benefits: 1) Support for all licensed frequencies from 6‐40 GHz via a common IF/telemetry/power interface. 2) Improved temperature performance due to the increased surface area of the unit. 3) Common ODUs with Trango GigPlus and GigaPro split architecture systems to simplify field sparing requirements. 4) System Gain equivalent to Trango Split architecture systems, among the highest in the industry. Traffic Capacity With QAM256 modulation in a 56 MHz channel, the link can support capacities up to 375 Mbps full duplex or 750 Mbps aggregate, with an additional T1 circuit provided for timing or TDM applications. The base model comes with 100 Mbps full duplex capacity and there are two upgrade keys available that can open the entire 375 Mbps capacity: AP‐Key‐1 Description: Unlocks throughput capacity from 100 up to 200 Mbps Full Duplex payload (200 Mbps each direction) – Covers one link – (2 license keys provided) AP‐Key‐2: Description: Unlocks throughput capacity from 100 Mbps up to Maximum capacity Full Duplex payload (375 Mbps each direction) – Covers one link – (2 license keys provided) Industry Leading System Gain The combination of the High Transmit power and superb receive sensitivity of the ODU provide for one of the highest system gains available on the market today. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 22 The technology behind the high system gain relates to the Low Density Parity Check (LDPC) forward error correction (FEC) coding that was implemented in the ApexPlus design.
The Figure below shows how the Low Density Parity Check (LDPC) coding, which replaces the older Reed‐Solomon lock coding, reduces the signal to noise ratio required to achieve a 1E‐6 Bit Error Rate (BER). As a result, the receive sensitivity is lowered by the same amount, typically 3 to 4 dB. Figure 6 LDPC vs. Reed‐Solomon Coding System gain is one of the most important metrics for a microwave system because it has a direct relationship to the link reliability, antenna size, and transmission distance as shown in the figure below. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 23 Full Licensed band frequency and T/R spacing support 11 GHz
8 GHz
10 GHz
Models
6 GHz
7 GHz
Due to the unique design, all standard frequency bands and T/R spacings are available for this product with no long product rollout delays. The Figure below shows the currently supported band and T/R spacings for ApexPlus, with the numbers representing the number of sub‐bands for each frequency band. ApexPlus is available in two base models, AP1‐XX‐YYYY‐ZZ, which utilizes the HP ODUs and AP2‐XX‐YYYY‐ZZ, which utilizes HP2 ODUs. 530
490/500
350
360
311.32
310
266
208
151.614
119/126
300
245
196
168
161
160
154
150
340/350
300
252.04
240
170
160
TR Spacing
2 2 3 3 4 2 3 3 16 3 5 3 3 6 3 4 2 3 2 3
3 4
4 4
4 4 4 2 3 3 16 3 5 3
6
4 2
2
1 3 4
42 GHz
38 GHz
32 GHz
28 GHz
26 GHz
15 GHz
13 GHz
Models
23 GHz
Common sub‐banding
18 GHz
AP1/HP1 ODU
AP2/HP2 ODU
1560
1008
1200
1232
800
1008
450
1008
812
700
1260
1500
1092.5/1120
1010/1008
728
Common sub‐banding
644
3
640
4
4
490
315
5
3
475
266
4
420
225
AP1/HP1 ODU
AP2/HP2 ODU
315/322
200
TR Spacing
4
4
3
3
4
4
2
2
3
3
1
1
4
4
3
1
1
2
2
3
3
4
4
1
1
3
3
3
2
2
2
2
4
4
2
2
2
3
Table 3 ApexPlus Band and T/R Spacing Options Specific information on the sub‐bands is shown in Appendix E. For AP1 models the TR spacing can be customized via a software command as long as the new TR spacing and channel bandwidths are within the diplexer range. See Appendix E for more information Channel Sizes from 3.5 MHz to 80 MHz Across all the frequency bands, the system can support channel sizes as low as 3.5 MHz. The channel sizes are user selectable. Table 6 shows the maximum Ethernet capacities for each symbol rate and modulation level. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 24 In addition, custom speed profiles can be added to replace the existing speed profiles. This allows optimization of various system parameters such as latency, sensitivity, and traffic capacity. Contact Trango Sales for more information. Adaptive Coding and Modulation Adaptive coding and modulation provides error‐free hitless changing of the modulation level for a fixed channel width to allow the link to be maintained during heavy weather related fading conditions. Instead of the link dropping and no traffic passing, the link will be maintained with a lower capacity until the fading condition is removed, at which time the link will return to the normal modulation level. The transitions between modulation levels are controlled by thresholds which are user‐
modifiable and each transition is made without dropping packets since both ends of the link coordinate the transition automatically. The Figure below shows the Adaptive Coding and modulation in action. Figure 7 Adaptive Coding and Modulation (ACM) Trango Systems, Inc. ApexPlus User Manual Rev 3.0 25 Link Protection through 1+1 Hot Standby Two ApexPlus units can be mounted using a combiner directly on a single antenna , and with an optional short jumper cable between the two units, provide 1+1 hot standby functionality to protect against a hardware failure of the one ApexPlus unit or a cable failure. The hot‐standby feature is available on all frequencies and can support layer 2 and layer 3 routed networks to allow immediate routing of the signal to the standby link. The failover time is typically less than 200 milliseconds. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 26 2.0 Wireless Operation Detail Channel Bandwidth The system supports the following channel bandwidths: 3.5 MHz 25 MHz 5.0 MHz 27.5/28 MHz 7 MHz 30 MHz 8.33 MHz 40 MHz 10 MHz 50 MHz 12.5 MHz 55/56 MHz 13.75/14 MHz 80 MHz 20 MHz The Speed is changed via the management interface using the speed command or a drop down box in the web interface. Both sides of the link must be changed independently to ensure the RF link is established. Modulation The following modulation levels are supported within each of the channel bandwidths shown above: QAM256 QAM128 QAM64 QAM32 QAM16 QPSK The modulation is changed via the management interface using the speed command or a drop down box in the web interface. Both sides of the link must be changed independently to ensure the RF link is established. Mean Squared Error (MSE) Mean Square Error (MSE) is similar to Signal‐to‐Noise Ratio (SNR) except that it accounts for distortion and interference in addition to noise power. Distortion may come from several sources such as bad Ethernet cables (poor shield, damaged, or low quality), path degradations such as multipath, or Fresnel zone encroachment. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 27 Interference can come from other transmitters on the tower, as well as from sources inside an indoor shelter. High power transmitters inside a shelter can cause interference when near the PoE device or when located very close to the cabling. There are maximum acceptable MSE values for each modulation which are useful in determining the quality of the link. The MSE value reported is only relevant to one tx‐rx path, so the MSE of each tx‐rx path must be evaluated to verify the link is operating as expected. The lower the number the better, so a ‐35dB is better than a ‐30dB. The table below shows the maximum MSE value to expect in IF Loopback, Normal Operation, and Absolute Maximum. MSE Expected and Maximum Values (dB) Maximum Expected value IF loopback QAM256
QAM128 QAM64 QAM32 QAM16 QPSK ‐36 ‐36 ‐36 ‐36 ‐36 ‐36 Maximum Expected value Normal operation at max power ‐34 ‐33 ‐32 ‐30 ‐30 ‐29 Absolute Maximum for 1E‐
6 BER Sensitivity Threshold ‐28 ‐25 ‐22 ‐19 ‐16 ‐9 Table 4 MSE Expected and Maximum Values Trango Systems, Inc. ApexPlus User Manual Rev 3.0 28 Adaptive Coding and Modulation (ACM) The ACM feature works in conjunction with the Mean Square Error (MSE) values. Using the acm command, the operator enables the ACM function and then sets the speed using the speed command. When ACM is enabled (on) and the link MSE becomes degraded, the radio will automatically shift down in modulation and speed based on the MSE degrade threshold setting shown in Table 5. Since the original set modulation may be QAM256, QAM128, QAM64, QAM32, or QAM16, the table shows each setting and total range of modulation levels that will be used for that setting. The threshold values can be changed by the operator if desired, however the default values shown have been thoroughly tested and are the recommended settings.
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 29 Speed Setting QAM256 Modulation Improve Degrade QAM256 ‐32.1 ‐27.2 QAM64 ‐29.2 ‐24.3 QAM16 ‐25.3 ‐18.5 QPSK ‐20.3 ‐17.1 Speed Setting using QAM128 Modulation Improve Degrade QAM128
QAM64 QAM32 QAM16 QPSK ‐32.1 ‐27.2 ‐29.2 ‐24.3 ‐26.3 ‐21.3 ‐25.3 ‐18.5 ‐20.3 ‐17.1 Speed Setting using QAM64 Modulation Improve Degrade QAM64 QAM32 QAM16 QPSK ‐29.2 ‐24.3 ‐26.3 ‐21.3 ‐25.3 ‐18.5 ‐20.3 ‐17.1 Speed Setting using QAM32 Modulation Improve Degrade QAM32 QAM16 QPSK ‐26.3 ‐21.3 ‐25.3 ‐18.5 ‐20.3 ‐17.1 Speed Setting using QAM16 Modulation Improve Degrade QAM16 ‐25.3 ‐18.5 QPSK ‐20.3 ‐17.1 Table 5 ACM Threshold Table !
The ACM feature will automatically shift the modulation level up or down based on the MSE value and the above specified thresholds. If you do not want the radio to change speed settings then disable ACM. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 30 ACM Detailed Description If the channel conditions degrade due to multipath or fading, the signal strength and consequently the MSE may be affected. This typically occurs during heavy rain and is more pronounced with higher frequencies. If the degrade threshold shown in the table is exceeded, the ACM engine will coordinate a shift of the modulation level down to the next level shown. No packets will be dropped during this transition since the two ends of the link are coordinating with each other to ensure that the switch occurs at the same time. Since lower modulation levels are more robust against channel fading and multipath, they can tolerate a higher MSE as is evident from the table. If the link conditions continue to degrade, the shifts downward will continue until the lowest modulation level, QPSK, has been reached. If further degradation occurs above the maximum MSE (shown previously in Table 5) for QPSK, the link will be dropped and packet loss will occur. If the link MSE starts to improve, however, the ACM engine will gradually shift the modulation level up as the improve thresholds are passed. When ACM is active the modulation level may be asymmetrical, meaning that one direction may be running at QPSK and the other may be running at the originally set higher modulation such as 256 QAM. This is because the ACM engine acts independently at each endpoint of the link. A low level Binary Phase Shift Keying (BPSK) channel is maintained between the two ends to allow very tight coordination of the switches in modulation. Only data traffic capacity in the direction towards the affected receiver will be reduced as the modulation level is reduced, maintaining performance on the unaffected direction. During all ACM operation the transmitter power remains at the set level if ATPC is off. If enabled, ATPC acts normally when ACM is active and may increase or decrease the transmit power based on RSSI levels and the ATPC maximum levels set for each modulation. This gives a significant advantage in the system gain since the maximum transmit power can be increased automatically as the modulation level is reduced. As the modulation level increases with improving channel conditions, the transmit power will be decreased. From the operator perspective all that is required is to set the maximum power levels for each modulation and enable ATPC. The acm command provides configuration of the ACM and must be done on both sides of the link. The linktest command from the CLI can be used to view the current TX and RX modulation levels. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 31 Wireless Link Capacity The table below shows the capacity of the system for each non‐ACM speed setting. The capacities for the ACM settings will be approximately 1‐2% lower due to the additional overhead of the ACM. All capacities shown are in Mbps full duplex, meaning that the aggregate bidirectional capacity is twice the number shown. The capacities shown are also layer 2 using 1518 byte packets for IPV4. Layer 1 numbers will be higher, especially for small packets: BW(MHz) QPSK 3.5 5 7 8.33 10 12.5 13.75/ 14 20 25 28/30 40 50 55/56/80 6 8 10 13 15 20 22 31 39 47 63 78 90 QAM16 QAM32 QAM64 QAM128 QAM256
9 12 20 26 30 40
45 63 80 95 128 157 181 15 19 25 33 37 49 55 78 99 118 159 195 225 18 24 31 40
46 60
67 96 120 142 192 238 275 21 27 36 46 53 70 78 111 140 167 225 277 320 23 31 40 52 60 78 88 126 160 192 256 318 365* *375 Mbps when set to speed 80 qam256, with symbol rate 49.9 Msym/sec Table 6 Max Link Capacity (Mbps) for non‐ACM Speed Settings Trango Systems, Inc. ApexPlus User Manual Rev 3.0 32 Automatic Transmit Power Control (ATPC) ATPC and targetRSSI work together to control the remote side power output in order to achieve optimal signal strength. ATPC can be enabled or disabled. When enabled, ATPC will adjust the power of the remote side based on the local targetRSSI setting. If the current RSSI value is lower than the targetRSSI setting of the local radio, the local radio will send commands over the air instructing the remote radio unit to increase its output power to achieve the targetRSSI setting within +/‐ 2 dB. If the RSSI value is higher that the targetRSSI setting, the remote radio will be commanded to reduce the power until either the target level is reached within +/‐ 2 dB or the TX power has hit the minimum level (See Table 8). ATPC also works in conjunction with the ACM mechanism to increase transmit power with modulation levels changes. The atpc max_power command allows setting the individual maximum power levels for ach modulation level from QPSK to QAM256 ATPC has Step Size and Max Power settings to limit the output power of the unit and prevent a violation of the license. ! The user set transmit power setting cannot be changed after ATPC is enabled. To manually change the power setting, ATPC needs to be disabled. ATPC Max Power & Step Size Settings for ATPC Max Power and the ATPC Step Size control how the ATPC function will behave while attempting to achieve the targetRSSI. ATPC Max Power is the maximum power setting ATPC can set the power output to when trying to reach the TargetRSSI. ATPC Step Size is the power level change in dB that ATPC can change power output. Larger step sizes result in faster response to fading conditions. Transmitter Maximum Power Output Maximum Transmitter power output is dependent on the band of operation and the modulation level. Both the AP1 and AP2 models have the same default maximum power levels for each band and modulation. AP1 models can be set to higher transmit power levels for some frequencies when the Power License Key (AP‐KE‐3) is enabled. See Table 7 for details. There is no dependency on the channel bandwidth used within a particular band. As an example, the power level for QAM256 within the 6 GHz band is the same for 3.5 MHz channels as it is for 56 MHz channels. The table illustrates this and shows the maximum set power levels for each model family, band, and modulation level. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 33 Maximum Transmit Power by Frequency (dBm) Modulation 6, 7, 8 10 11 13,15 18‐26 28‐40 QPSK 30 26.5 28 26 25 23 16QAM 28 22.5 26 22/25* 22/23* 21 32QAM 28 22.5 26 22/25* 22/23* 21 64QAM 25 20.5 22/25* 21/24* 20/22* 17 128QAM 25 20.5
22/25*
21/24*
20/22*
17 256QAM 24 18.5
21/24*
20/23*
19/21*
16 *With high power license key (AP‐KEY‐3) on AP1 models only Table 7 Maximum Set Power Levels by Band and Modulation When ATPC is active, the atpc_max power should be set to the maximum power for the each modulation used if adaptive power changes are desired with ACM modulation changes. If the power level to remain constant across ACM modulation changes, all atpc_max power levels should be set to the max power of the highest modulation level, typically 256QAM. If ATPC is off then the power will not be changed under any circumstance and will remain at the level set by the operator. Transmitter Minimum Power output The minimum transmit power that can set is limited by the ODU model and is not dependent on the modulation level like the maximum levels are. The table below shows the minimum power levels for each band and model family. The levels are also the minimum levels that ATPC can set the output to when enabled. ApexPlus Model Transmitter Minimum Power Output Level (dBm) 6 GHz 7 GHz 8 10 11 13 15 18 GHz GHz GHz GHz GHz GHz AP1‐XX‐YYY‐ZZ +9 +9 +9 NA +6 +3 +3 AP2‐XX‐YYY‐ZZ +0 +0 +0 +0 +0 +0 +0 23 GHz 26 GHz 28 GHz 32 GHz 38 GHz +2 +2 +2 +2 +1 +1 +0 +0 +0 +0 +0 +0 Table 8 Minimum TX set power by band Trango Systems, Inc. ApexPlus User Manual Rev 3.0 34 Receiver Maximum Input The maximum receiver RF level, measured by RSSI, is depicted in Table 9 below. If the RSSI value is higher than listed for the modulation being used, packet loss may result. When operating short range links with a high receiver input level, always make sure that the transmitter power is adjusted down from the maximum to ensure the levels shown below are not exceeded, or active ATPC with a targetrssi that is at least several dB below the levels shown to provide a safety margin. Modulation Level Max RSSI 256 QAM ‐24 dBm 128 QAM ‐22 dBm 64QAM ‐20 dBm 32QAM ‐18 dBm 16QAM ‐16 dBm QPSK ‐14 dBm Table 9 Max Receive Level Input Trango Systems, Inc. ApexPlus User Manual Rev 3.0 35 3.0 Network Operation Detail This section describes key network related elements of the system in detail. 1+0 Non‐Protected Link Configuration The diagram below shows the typical setup of the ApexPlus in a network environment. Although this configuration is call non‐protected, it is commonly used in ring architectures which use layer 2 or 3 routing to reroute the traffic the other direction if the link fails. Figure 8 shows the unprotected 1+0 link setup with switches or routers. Figure 8 1+0 Setup Trango Systems, Inc. ApexPlus User Manual Rev 3.0 36 1+1 Hot Standby Protected Link Configuration Figure 9 shows the protected 1+1 hot standby configuration. This configuration consists of two ApexPlus units at each end of the link. The easiest way to think of a 1+1 setup is a single 1+0 link operating normally with another standby link ready to take over in the event of a failure condition. The standby units monitor the active link, including receiving the same signal from the far end, but the standby does not transmit a signal unless it becomes the active unit as the result of a failure detection and subsequent failover event. The standby units also monitor the health of the active unit by polling it through the redundancy cable part number CBLDAT‐RIU4. If there is an event that triggers a failover from active to standby, both ends of the link will switch to the standby link. This means that a Network switch or Router capable of Rapid Spanning Tree Protocol (RSTP), BGP or OSPF routing must move the traffic to the standby link on both ends. To assist in this process, Rapid Port Shutdown (RPS) can be enabled as an action after a failover occurs. Figure 9 1+1 Setup Trango Systems, Inc. ApexPlus User Manual Rev 3.0 37 The Table below shows the events will cause a failover from active to standby: Event Failover Type (local Site) Failover Type (remote pair) Modem link lost on Active Hardware
Hardware
CLI “utype_switch” Software Hardware Power supply failure on Active Software Hardware Reboot on Active Software Hardware ODU PLL failure on Active Software
Hardware
Violation of threshold setting Software Hardware Link related command (see list) No failover Hardware Power supply failure on Standby No failover No failover Reboot on Standby No failover No failover Odupower on/off on Standby No failover No failover ODU PLL failure on Standby No failover No failover Modem link lost on Standby No failover No failover 1+1 cable removal/failure No failover No failover ACM Tx/Rx profile changes No failover No failover Table 10 Failover Events Hardware triggered failover In the event that the modem RX link is lost (status changes from “1” to “0”), a hardware triggered failover will occur and the following sequence of actions will occur: Actions: 1) The IF transmit signal will be shut off on the active unit and enabled on the backup unit 2) The standby ApexPlus utype will change from standby to active and the previously active unit utype will change to standby. 3) The Ethernet port will be shut down on the new standby unit if RPS was enabled. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 38 4) The far end of the link will also failover since the transmitter switch will cause the far end to lose lock as well. Steps 1‐3 above will repeat for the far end. Hardware initiated failover to the backup pair will occur on the far end unit due to the small gap in the transmitter being switched from active to standby on the local side. The total time for the failover to occur is typically 150‐200 milliseconds. A hardware failover will only occur the following initial conditions are met, otherwise none of the events in the Table will cause a failover. 1)
2)
3)
4)
A Standby unit is detected The active Radio has its RX locked. The election time period is over. The guard time has elapsed Software triggered failover Software triggered failover is Initiated by the software based on the following conditions. Software failovers will take 3‐ 5 seconds due to the fact that the events are polled by the operating software inside the unit. 1) ODU PLL unlocked 2) Violation of a threshold setting when failover is configured as one of the threshold actions. 3) Power Supply failure User triggered (manual) failover Initiated by user issue CLI/SNMP/web commands as shown below. Typically the only user triggered command that should be executed is the utype_switch command, which is used when the original active unit is restored or replaced and the operator wants to return it to active status. The other commands are listed to make the operator aware that they will cause an unintentional (and usually undesired) failover. Commands that will force a failover 1. Using the utype_switch command to restore the active after a failover a. This command can only be initiated on the Active unit. b. A low level command is sent from Active to Standby unit to turn on transmitter. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 39 2. User commands: When the operator changes the following settings on the active unit, an unintentional failover may occur. It is not recommended to run any of these commands while an active 1+1 link is running: a. acm enable b. bootimage upgrade odu c. datapath d. data pattern e. loopback f. opmode g. odupower h. power i. reboot j. speed Rapid Port Shutdown (RPS) ApexPlus supports the shutdown of the Ethernet ports to assist in rerouting traffic in the event of a link failure. When enabled at both ends of the link, All Ethernet ports at both ends of the link will be shut down within 50 mS of the modem lock status changing from “1” to “0” at either end of the link. RPS emulates a cable failure if the entire link is thought of as a cable, and will trigger a routing change when used with a switch or router setup for Rapid Spanning Tree Protocol (RSTP) or another layer 2 routing protocol at both ends, as is normal in a ring architecture. For higher layer routing protocols the ports are normally left active in the event of a link loss. It is highly recommended that the operator enable ACM when using RPS since the fade margin will be much higher than a non‐ACM speed setting, preventing link loss and subsequent rerouting during weather related events. VLAN Tagging ApexPlus supports tagged packets with VLAN IDs ranging from 0‐4089. The last seven VLAN IDs are used internally as described in the Port Mapping Section below. If In‐Band Management (IBM) is used and the OMU model is AP‐OMU‐1, the management traffic must have a VLAN tag to allow the switch internal to the system to identify packets in the data stream and direct them to the CPU for processing. The VLAN ID for management is user specified using the ibm command, with a factory default VLAN ID of 4085. For AP‐OMU‐2 models, IBM without a VLAN is allowed in addition to IBM with VLAN. Q in Q Support : ApexPlus supports double tagged packets on all ports using Ethertype 9100 and 88A8, but no QoS will be performed on these packets. If Service Provider Trango Systems, Inc. ApexPlus User Manual Rev 3.0 40 Tagging and reprioritization is desired, Ethertype 8100 should be used by the provider in the outer tag on customer traffic. In other words, the service provider can override the priority field in any packet by adding another VLAN tag with a new priority to the packet using a switch just before the Radio input. The ApexPlus will apply QoS to the outer tag as long as the Ethertype is 8100. Port Mapping (802.1q) The port mapping feature is a fixed setting and provides an additional amount of data security since traffic on the Ethernet port is segmented and isolated from traffic on the fiber port. Port mapping is implemented by using VLAN tags internal to the ApexPlus link. When Ethernet Traffic arrives in a port, it may be tagged or untagged. Both tagged and untagged packets are tagged with an additional internal VLAN Tag depending on which port they arrived at as follows: GE1: GigE 10/100/1000BaseT port :VLAN ID 4091 GE2: SFP port: VLAN ID 4092 At the other end of the link, the internal tags are removed and the original packets are sent out unaltered. Essentially the ApexPlus is performing double tagging on packets that have already been tagged. Quality of Service (QoS) (802.1p and Diffserv) ApexPlus internal switch fabric performs QoS on all incoming packets to allow the operator to give priority to certain traffic types. The following fields are used to classify the incoming traffic: -
Layer 2 using the COS bits in the VLAN tag on incoming Ethernet traffic (Tagged traffic only) -
Layer 3 Diffserv (DSCP) using the Differentiated services field in IP packets. The DSCP mapping can be controlled on a port by port basis from CLI or Web. -
Port Priority for untagged traffic The incoming traffic is mapped into 4 queues (FIFOs) which are emptied into a single data pipe going into the modem and subsequently over the air. The scheduling of the queue traffic into the modem data pipe can be either strict or Weighted Round Robin (WRR) Strict QoS Mode, which applies to the VLAN COS field only, follows the logic rule below: COSQ3> COSQ2> COSQ1 > COSQ0 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 41 This rule essentially means that the system will empty COSQ3 before sending any COSQ4 packets across the link, and if both COSQ3 and COSQ2 are empty then COSQ1 packets will be sent, etc. Note that while strict priority ensures that ALL high priority traffic will go through (up to max burst size and link capacity limits), it may block lower priority traffic or increase the latency significantly for lower priority packets during traffic congestion. The default priority mapping of the packet will be set as follows: COS priority 0 Æ COSQ0, Lowest Priority Queue COS priority 1 Æ COSQ1 COS priority 2 Æ COSQ2 COS priority 3 Æ COSQ3, Highest Priority Queue These default mappings can be changed with the qos command, allowing the packets to be mapped into any one of the 4 queues based on the COS bit in the VLAN tag. Different priority tags may be mapped into the same queue if desired. In WRR QoS Mode, both COS and DSCP bits are used. The DSCP field in the IP packet will contain a number from 0‐63 in the Type of Service (TOS) field, which can be mapped to a priority level, which is subsequently mapped to a queue. WRR mode allows weights to be applied to each queue to allow the QoS engine to spend at least some portion of time emptying the queues. This mode is useful for allowing at least some of the lower priority traffic to get through the link and ensuring that MOST high priority traffic will go through. Both COS and DSCP fields are monitored on the incoming traffic for assignment of packets to the queues. The traffic can be classified into 8 priorities (0‐7 based on the VLAN tag COS/DSCP bits). This is done external to the GigaPlus unit using a switch or application to set the priority tag field or by the application. Once the tagged traffic with COS/DSCP priority bits set arrives in the GigaPlus Ethernet port, the internal switch will perform prioritization on the traffic by mapping it to one of 4 queues. Port Priority The port priority feature allows for untagged traffic arriving into each Ethernet port to have priority level assigned to it. If the arriving traffic is already tagged then that tag priority level will be honored over the port priority. The port priority setting will determine which port traffic is forwarded in the event of more traffic coming into all the ports than the capacity of the system can handle. Port priority can augment port rate limiting, especially in when ACM is active and the link has downshifted to a lower modulation. The port command is used to set the port priority for each port. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 42 Port Rate Limiting (Ingress) The port rate limiting feature is used to restrict the ingress traffic rate on a specific Ethernet port. This is useful for Service Level Agreements (SLAs) when both ports of the GigaPlus are being used to supply two customers and the channel capacity is limited to less than the sum of the capacity of the two Ethernet ports. For example, if both ports are set to 1000BaseT, and the RF channel capacity is 375 Mbps, setting GE1 to rate limit of 125 Mbps and GE2 to a rate limit of 250 Mbps will always guarantee that both users have the bandwidth of the channel reserved for them. Packets are dropped before QoS processing, so if QoS is desired the port rate should be set to match the line rate (default). Egress Margin Egress margin is used to fine tune the behavior QoS when using VLAN tagged traffic marked with COS priority (802.1p), or when using port priority to assign priorty to untagged traffic on multiple ports. Traffic coming into the Ethernet ports is bursty by nature and may exceed the radio link capacity if the radio speed is less than the Ethernet line speed (10/100/1000 Mbps). To reduce or eliminate traffic loss in this case, buffers are used inside the OMU. These are the same buffers used for QoS traffic grooming. The traffic from all Ethernet ports share the buffers and are serially fed to the radio section at a rate equal to or slightly less than the radio capacity. The egress margin simply controls the egress rate in Mbps from the switch as a percentage added or subtracted for the nominal link capacity. The default is 0% which means that the rate from the switch into the modem section will be equal to the total link capacity. This setting will provide the best throughput for all packet sizes, but may allow some high priority packets to be dropped when the channel is overloaded (input rate > link capacity). By setting the egress margin to between ‐2 and ‐15 percent, the QoS will be enforced and no high priority packets will be dropped. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 43 4.0 Link Management This section describes the various ways to manage and monitor the health and performance of the ApexPlus microwave backhaul link. Overview The ApexPlus can be managed through the following methods: Graphical User Interface (GUI): Web Browser: Remote access via in band and out of band methods with two level view and configuration level access using any standard web browser such as Internet Explorer, Chrome, Firefox, and Safari . Command Line Interfaces SSH – Encrypted remote access via in band and out of band methods with separate view and configuration level access (password protected) Telnet – Remote access via in band and out of band methods with separate view and configuration level access (password protected) Console – Local Access using a serial cable for bench configuration with separate view and configuration level access (password protected). SNMP – Remote control and monitoring via in‐band and out‐of band methods using any third party Network Management Software (NMS). See Appendix D for details on the MIB and SNMP objects. Standard MIB II System Level and Enterprise MIB Blocks are supported with monitoring for all major link health and traffic related metrics. Default IP Address The factory configuration for IP address is 192.168.100.100 for all units, and the IBM default address is 172.16.1.1 for the ”A” side unit and 172.16.1.2 for the ”B” side unit. Default Passwords The default passwords are shown in the table below: Trango Systems, Inc. ApexPlus User Manual Rev 3.0 44 Access mode Username Password CLI View Mode admin trango CLI Config Mode N/A trango CLI Debug Mode N/A N/A Web View Mode admin trango Web Config Mode config trango SNMP Read Community N/A public SNMP Write Community N/A private SNMP Trap N/A trapstr Table 11 Default Login Passwords Graphical User Interface (Web Browser) To access the browser interface simply open your Web browser and enter the IP address of the radio. A login window will pop up, requiring a user name and password (Figure 10). Enter the default (user= “admin”, pw = “trango”) or modified user name and password then press OK to bring up the View mode Browser interface. Figure 10 Web Browser Login In View Mode, no changes can be made to system operating parameters, but statistics and current settings can be viewed. If changes are required, the user can log in to the Config Mode by selecting the Config Login button at bottom left. The default username is “config” and the default password is “trango”. The first page to display will be the System Info Page as shown in the Image below: Trango Systems, Inc. ApexPlus User Manual Rev 3.0 45 Figure 11 System Info Page The main format of the ApexPlus Web Interface is shown in Figure 11 above. The layout is designed to allow the operator to view the current link status on all pages. The left side of the display shows various pages organized by function. Each page can be opened and explored by simply clicking on the italicized page name. Below is a description of each function. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 46 Navigation Bar: The navigation bar the left shaded area containing the functional categories. The navigation bar contains the following categories: •
Radio Setting: The essential Radio Link setup parameters, TX/RX frequency, transmitter power, ATPC, speed and modulation, as well as the capacity license are found here. Settings for 1+1 failover are found here as well. •
Network Settings: The essential Network setup parameters, such as IP address, In Band Management (IBM), Ethernet port settings, Quality of Service(QoS) and SNMP setup are located here. •
System Status: Shows most of the basic configuration parameters of the radio, including firmware versions, OMU/ODU models and serial numbers, and Management port MAC addresses. All port and radio link status are shown here as well. The link test command can be run here to view the current RF link state •
System Statistics: Counter/status information on all interfaces RF, Ethernet, and T1/E1 ports is displayed. These statistics are refreshed automatically and can be cleared from the web page. •
Diagnostics: This section contains pages that show current system settings, the system log which records all the events and user settings, and a special diagnostic export function that produces a text file for Trango Tech Support to use when troubleshooting is required. This folder also has a page to control the loopback functions, view the syslog, and run other special diagnostic functions. •
User Setting: User can change the web view and config passwords, change the system remark field and change the web refresh rate. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 47 Command Line Interface (CLI) using SSH, Telnet or Console All typical radio functions can be managed via the browser interface, but the Command Line Interface (CLI) has additional functionality that facilitates installation and troubleshooting. The Command Line Interface has 3 nodes: View, Config, and Debug. Logging into the radio via Command Line Interface is covered here briefly, and a complete listing of all CLI commands is provided in Appendix A Logging into the radio via Command Line Interface is covered here briefly. A complete listing of all CLI commands is provided in Appendix A ‐ Command Line Interface. Launch Telnet Open a command prompt (DOS) session on your PC (Windows® Start icon and select “Run”). Open a Telnet session by typing: telnet [ip address of radio]
Example: C:>telnet 192.168.100.100
Once at the CLI login prompt, type in the login and press enter, then the password and press enter.
CLI login: admin
Password: (No characters will be display during input)
Trango System:
v1.0.0
TrangoLINK ApexPlus Command Line Interface
(CLI-view)#
If the incorrect password is entered during login, the system will allow two more tries before terminating a telnet session. A new session will need to be open to try again. To terminate a CLI session (Telnet or Console) simply close the console window. A CLI SESSION CAN ALSO BE TERMINATED FROM THE DEBUG NODE WITH “EXIT” COMMAND. View Node : (CLI-view)# prompt allows view level only, and no parameters of the radio link can be changed. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 48 Config Node: (CLI-config)#, This node is accessed by typing in the command config from the view node. The system will prompt for a password and after successful authentication, the config node is enabled. All configuration settings are changed within the config node. Any command entered without any parameters returns the current configured values similar to “view” node. Most configuration changes are applied immediately and do not require a reboot. All config changes must be saved to FLASH memory by issuing the config save
command. This can be done after all the changes desired are made within a single session If the configuration is not saved, the system will restore the last saved settings after reboot. ! ALL CONFIGURATION CHANGES HAVE TO BE SAVED TO FLASH IN ORDER TO BE PERSISTENT ACROSS A REBOOT. A SINGLE “CONFIG SAVE” COMMAND WILL SAVE ALL CONFIGURATION CHANGES The operator can go back to the “view” node by using the exit command from the config node.
Example: CLI login: admin
Password:
Trango System:
v1.0.0
TrangoLINK ApexPLUS Command Line Interface
(CLI-view)# config
Password:
(CLI-config)#
(CLI-config)#exit
SUCCESS
(CLI-view)#
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 49 The Command Line Interfaces keeps a history of commands used, pressing the up arrow will display previous commands used. The CLI can supports auto‐complete of a command being typed by pressing <tab> key. If a command is partially typed followed immediately by a “?” it will display all related commands. Example: (CLI-config)#
targetrssi
tdm
telnetd
temp
tftpd
threshold
trap
(CLI-config)#
? (The ? will not be display)
Set target RSSI level for ATPC
Display TDM configuration
Enable/Disable telnetd
Display IDU and ODU temperature
Enable/Disable tftpd
Set the threshold for the radio parameters
Display snmp trap management information
!
TYPE “?” FOR A LISTING OF ALL CLI COMMANDS. Changing Password The debug and view node share the same password. The config node has a separate password. The view and debug mode password is changed in the debug mode. The config node password is changed in the config node. Use the CLI command passwrd to change the password. The example below demonstrates changing the password for the config node to “control” Syntax: password <newpassword> <newpassword>
Example: (CLI-config)# passwrd control control (The password must be entered twice)
If the command is properly executed, the system will return a “SUCCESS” and return to the CLI‐config prompt. If the password is lost and the unit is locked, the pushbutton on the access panel can be used to reset the password and default IP back to the factory settings Console Port ApexPlus features a console port which is multiplexed with the port for the 1+1 hot standby operation. If 1+1 hot standby is active the console cable cannot be used. The console port is useful in the event that the unit cannot be accessed via TCP/IP (HTTP or Telnet). A Terminal Emulation program such as HyperTerminal or Putty can be used to access the radio’s CLI via the console port as shown in Figure 12. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 50 Figure 12 Console Port Setting Simple Network Management Protocol (SNMP) TrangoLINK® ApexPlus supports Simple Network Management Protocol (SNMP) for network management. Network management consists of 4 categories: 1. Configuration 2. Accounting 3. Alarm 4. Monitoring/Control These capabilities allow the network operator to provide superior services through higher network accessibility and integrated accounting system. Use of SNMP requires the customer to have already implemented a NMS or SNMP software package. The Trango SNMP solution supports MIB‐II (system only) and the Trango proprietary Management Information Base (MIB). Users interested in using the SNMP functionality should review the entire TrangoLINK® ApexPlus MIB, found in Appendix D, for a complete understanding of its features. The following is an overview of some of the more commonly used SNMP objects in the TrangoLINK® ApexPlus system. A complete listing can be found in Appendix D. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 51 A copy of the MIB files for the current firmware version can be obtained by contacting Trango Technical Support. Common Objects for Monitoring and Control GigE Bandwidth Monitoring •
gigeEth1InOctets: Number of octets of payload received on GigE port 1 (copper). •
gigeEth2InOctets: Number of octets of payload received on GigE port 2 (fiber). •
gigeEth1OutOctets: Number of octets of payload transmitted on GigE port 1 (copper). •
gigeEth2OutOctets: Number of octets of payload transmitted on GigE port 2 (fiber). RF Monitoring •
rfInOctet: Number of octets of payload received on the RF port. •
rfOutOctet: Number of octets of payload transmitted on the RF port. •
rfEthernetInPackets: Number of octets of payload received from the GigE ports to transmit on RF port. •
rfEthernetOutPackets: Number of octets of payload transmitted to GigE ports from RF port. •
rfRSSI: The Receive Signal Sensitivity Indicator the unit receives from the distance end of the link. Link Status Traps Various traps are defined as follows: •
trapReboot: trap is triggered when the unit is rebooted. •
trapStartUp: trap is triggered when the unit boots up. •
trapBackupLink: trap triggered when the backup status changes. •
trapBackupTakeover: The trap is triggered when the Backup unit has taken over. •
trapModemLock ‐ This trap will inform you when there is a change to the link lock. •
trapDownShift ‐ This trap will inform you when the modulation of the radio has shifted downed. Trango recommends monitoring RSSI, MSE, Ethernet Traffic (gigeEthOctets), Temp, and modem lock as a minimum for thorough monitoring of the link. Additional objects and traps can be added to the monitoring software as required. Please review Appendix D MIB for a complete listing of MIB Objects and Traps. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 52 Understanding and familiarization of Simple Network Management Protocol (SNMP) concepts and software platforms are required to utilize SNMP management of the TrangoLINK® ApexPlus system. Due to the large number of programs available for SNMP, Trango does not provide support of SNMP software packages or NMS systems. Some common items to try while having issues monitoring specific OIDs are: •
Properly load the MIBs into your software •
Try adding a “ .0 “ at the end of your OID string Firmware Upgrade The firmware on the TrangoLINK ApexPLUS can updated to a newer version through IBM or OBM Ethernet Ports. A firmware release consists of up to two files which contains the appropriate software files that are loaded onto the OMU and ODU: OMU OS Image Firmware File < omu.apexplus_<version>.tar.gz> ODU Image Firmware File <odu_fw.bin> If only the OMU firmware was changed then the ODU firmware does not need to be updated. Before beginning the update procedure, be certain that all required files have been downloaded to an easily accessible directory on your local hard drive. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 53 Upgrade Procedure ‐TFTP ! ALWAYS CONSULT THE UPGRADE INSTRUCTIONS THAT ARE INCLUDED WITH A NEW FIRMWARE RELEASE AS CERTAIN FILES MAY NOT BE REQUIRED FOR AN UPGRADE. 1) Place the firmware files in an easily accessible directory path on your computer. 2) Telnet into the radio by Clicking on Start menu then RUN. The figures use the default IP address; you must use the correct IP address for the TrangoLINK ApexPlus. Figure 13: Windows Start & Telnet 3) At the login enter your username and password. The username is “admin “and default password is “trango” 4) Enter config node by typing “config” and entering you write access password. The default config node password is “trango” 5) Enable the tftp daemon using the TFTPD command as shown below. Login as: admin Password: Trango System: TrangoLink ApexPLUS Command Line Interface v1.0 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 54 (CLI‐view)# config Password: (CLI‐config)# (CLI‐config)# tftpd on tftpd: on SUCCESS (CLI‐config)# 6) Open a MS‐DOS prompt (or other CLI interface) window and access the directory that you extracted the firmware files. C:\CD Firmware C:\Firmware 7) Using windows TFTP command line tool, we will upload the firmware file. The tftp syntax and an example are below. TFTP [‐i] host [GET | PUT] source [destination] C:\firmware>tftp ‐i 192.168.100.100 put omu_apexplus_v10.tar.gz Transfer successful: 1951744 bytes in 15 seconds, 130116 bytes/s 8) Once the file has been transferred successfully, log back into the unit and apply the updates into the FLASH memory using the bootimage command from the config mode. Each firmware needs to be upgraded on the unit using the bootimage upgrade command. (CLI‐config)# (CLI‐config)# bootimage upgrade omu NOTE: THE BOOTIMAGE UPGRADE COMMAND MUST BE ALLOWED TO COMPLETE BEFORE THE SYSTEM IS REBOOTED. IF THE SYSTEM IS REBOOTED DURING THE WRITING OF THE IMAGE TO FLASH, THE FLASH MAY BECOME CORRUPT – WAIT FOR THE SUCCESS INDICATION BEFORE PROCEEDING. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 55 If the ODU firmware was also being upgraded, the ODU file would be transferred to the ApexPlus using the same method as the OMU file. After loading the file, the bootimage upgrade odu command would be used to write it to FLASH. (CLI‐config)# bootimage upgrade odu 9) A reboot of the radio is required to load the new image after upgrade (CLI‐config)# reboot The upgrade time varies depending upon the images and the size of the image. The firmware can be verified by logging into the radio via the CLI through the version command or Web browser version page under the Firmware Version section. The Current firmware is the currently running firmware. The firmware which was replaced will be located in the Pprevious images. Upgrade Procedure ‐FTP To perform the firmware upgrade using FTP, use the ftp command to load the images into memory, then the bootimage upgrade commands just as with the TFTP method. The FTP method is much faster and has built in error checking. All that is needed is the IP address of the ftp server, a username/password, and the filename to be uploaded. The new file to be uploaded should be placed on the server. The ftp server will prompt for the password before allowing access. 1) Put the new software files on the ftp server using the ftp put command from a local computer (these commands are not done from the Trango equipment).
ftp> put <source file> <destination>: The <source> will be the filename only. The <destination> will include both path and file name. 2) After putting the file onto the server, log into the ApexPlus and run the ftp command from the command line as follows to open access to the server: ftp <server_ip> <user_name> password: xxxxxxx If prompted for the password multiple times, check the connectivity to the server by pinging the FTP server IP address from the debug prompt. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 56 3) Next , get the file from the FTP server by typing the get command from the ftp prompt. ftp> get <file_name> 4) Logout of the ftp session ftp> logout: logout of ftp session. 5) Run the bootimage omu and/or bootimage odu command as required. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 57 Capacity/Transmit Power Upgrades The ApexPlus speed capacity is standard at 100 Mbps. To upgrade the capacity or Transmit power for AP1 models, an alphanumeric key will be required. This key can be purchased from your Trango sales representative. To update the capacity/power key from the Web, copy and paste the applicable key into the Speed or Power License field on the Link Setup Page. Click the submit button. If the license is accepted, the word “Enable” will be displayed as shown below and replace the blank field. Figure 14 Capacity Upgrade – Web The capacity key can also be entered using the license command from the command line interface. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 58 5.0 Link Planning This section describes the process that occurs before installing and setting up an ApexPlus microwave backhaul link
Frequency/Path Planning Most microwave links use licensed spectrum that requires third party coordination to ensure minimal interference will occur to nearby licensed spectrum users. To ensure success, a path analysis must be done for each link that is being considered. Antenna heights, system gain, rain region and terrain data are evaluated to determine the reliability of the link over time and changing weather. Trango will run path analysis for its customers using industry standard software, evaluate different equipment options to achieve the customer goals, and assist the coordination process. Site Selection After the Planning phase is complete, it is essential that the proposed site be physically evaluated by the operator to ensure that no buildings or vegetation has crossed into the Fresnel zone that would affect operational reliability. It is not uncommon for tall buildings to be located in what would otherwise be a perfect non blocked line of sight path based on terrain data, but too often this is discovered when the installation is being performed. The site must also be evaluated for power and shelter provisions.
Licensing Licensing of spectrum is typically done on an individual path basis. In the US, the FCC will grant licenses for 11 years for paths that do not interfere with other users after the coordination and fees have been paid. Contact Trango for more information on the above topics.
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 59 6.0 Installation This section describes the installation to ensure that the ApexPlus units are correctly installed. Failure to follow these procedures may result in damage to the equipment and void the factory warranty.
Safety Installing microwave equipment can be dangerous. Please take the following precautions when installing or performing maintenance on the equipment. Equipment Protrusions: The equipment has been designed to be free of unnecessary protrusions or sharp surfaces that may catch or otherwise cause injury during handling. However, always take care when working on or around the equipment. Laser and Fiber Optic Cable Hazards: Trango fiber optic SFP Module transmitters are IEC60825‐1 / 21CFR1040‐1 Class I compliant and present no danger to personnel in normal use. However: Do not look into active unterminated optical ports or fibers. If visual inspection is required ensure the equipment is turned off or, if a fiber cable, disconnect the far end. Follow the manufacturer's instructions when using an optical test set. Incorrect calibration or control settings could result in hazardous levels of radiation. Protect/cover unconnected optical fiber connectors with dust caps. Place all optical fiber cuttings in a suitable container for safe disposal. Bare fibers and fiber scraps can easily penetrate the skin and eyes. Lifting Equipment: Be careful when hoisting or lifting the ODU or its antenna during installation or maintenance. The ApexPlus unit is nominally 15 lbs. However, antennas with their mounting hardware can weigh in excess of 100 kg (220 lb) and require specialized lifting equipment and an operator trained and certified in its use. Protection from RF Burns – Trango ODUs: Trango ApexPlus ODUs do not generate RF fields intense enough to cause RF burns, however, installers/operators should comply with the following cautions: 1) It is hazardous to look into or stand in front of an active antenna aperture. Do not stand in front of or look into an antenna without first ensuring the associated transmitter or transmitters are switched off. 2) Do not look into the waveguide port of an ODU when the radio is active. Protection from RF Burns ‐ Tower Site: When the ApexPlus ODU is to be installed where existing antennas are located, avoid exposure to potentially harmful levels of RF radiation from these antennas by: 1) Determining the RF exposure risk. If necessary ask the structure/tower owner or operator. When necessary, wear a protective suit or have the transmitter(s) switched off for the duration of the installation. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 60 2) Do not stand in front of or look into any antennas. Safety Warnings: When a practice or procedure poses implied or potential harm to the user or to the radio equipment, a warning is included in this manual. Airflow Requirements: Installations must be made so the airflow required for safe and correct operation of Trango equipment is not compromised. For the ApexPlus, unobstructed air passage must be maintained to all sides of the unit, and the gap between the OMU and ODU must not be blocked. Circuit Overloading: When connecting the ApexPlus, determine the effect this will have on the power supply, circuit protection devices, and supply wiring. Check ApexPlus power consumption specifications and the supply capability of the power supply system. This check of capacity must extend to the dc power supply and not just to an intermediate connection point. Power Supply Earthing: ‐48 V power supply earth must be connected directly to a bonding jumper from an earthing terminal bar or bus. Electrostatic Discharge (ESD): ESD can damage electronic components. Even if components remain functional, ESD can cause latent damage and/or premature failure. Always wear proper ESD grounding straps when handling or touching any PCB assemblies. Connect your ESD grounding strap to the ground connector on the ODU or PoE units as applicable Fiber Optic Cables: Handle optical fibers with care. Keep them in a safe and secure location during installation. Do not attempt to bend them beyond their minimum bend radius. Protect/cover unconnected optical fiber connectors with dust caps. Ground Connections: Reliable grounding of the system must be maintained. Refer to instructions in this manual for grounding of the ODU, ODU cable, lightning surge suppressor, and IDU. Lightning Surge Suppressor: ApexPlus Ethernet cables must be fitted with surge suppressors to prevent damage to equipment. Contact Trango for further details. Mains Power Supply Routing: ApexPlus DC power, T1/E1, Ethernet data and management cables are not to be routed with any AC mains power lines. They are also to be kept away from any power lines which cross them. Ambient Temperature: The ambient temperature range for the ApexPlus is ‐40° to +65° Celsius. To ensure operation and to maximize long term component reliability, ambient Trango Systems, Inc. ApexPlus User Manual Rev 3.0 61 temperatures must not be exceeded. Operational specification compliance is not guaranteed for temperatures outside this range. Mechanical Loading: When installing the ApexPlus unit and antenna/remote mount on a tower mount or building, ensure the mount is securely anchored first and can support the full load of the radio unit and antenna. Ensure that the additional loading of an ApexPlus unit will not cause any reduction in the mechanical stability of the mount. Power Supply Connection: The ApexPlus radio has the positive pin on its dc power supply connector connected directly to the chassis, which is in turn connected directly to the earth ground through the tower leg. ApexPlus radios must be used with a ‐48 Vdc power supply which has a positive earth; the power supply earth conductor is the positive supply to the radio or PoE injector. 1) There must be no switching or disconnecting devices in this earth conductor between the dc power supply and the point of connection to an ApexPlus system. 2) The power supply must be located in the same premises as the ApexPlus system. 3) All Ethernet cabling which is carrying power to the ApexPlus radio unit from the PoE injector must be 24 AWG solid strand Cat 5e or Cat 6 Shielded Twisted Pair (STP) cable with all 8 conductors terminated using shielded connectors. A low impedance connection must be made between the cable shield and connector ground shield. Power Supply Disconnect: An appropriate power supply disconnect device should be provided as part of the building installation. Rack Mount Temperature Considerations: If the ApexPlus PoE unit is installed in a closed or multi‐unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. The maximum ambient temperature of +65°Celsius applies to the immediate operating environment surrounding the PoE unit, which, if installed in a rack, is the ambient within the rack. Restricted Access: The ApexPlus system must be installed in restricted access sites. The PoE unit and associated power supply must be installed in restricted areas, such as dedicated equipment rooms, closets, cabinets, or the like. Access to the tower and ODU/antenna location must be restricted. Note: For USA: In restricted access areas install the ApexPlus system in accordance with articles 110‐26 and 110‐27 of the 2002 National Electrical Code ANSI/NFPA 70. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 62 Installation Process The standard procedure for installing the equipment is as follows: 1) Install antenna 2) Install previously configured ApexPlus unit on antenna at both ends 3) Align antennas 4) Proceed to commissioning. CAUTION: ApexPlus has no user serviceable parts, including the cable between the OMU and the ODU. Only factory certified personnel should make any changes or repairs to the units. Preparing for Installation Tools The following tools are required for installation: Adjustable Open Ended Wrench Ethernet Cat5e cable crimp tool #2 Flat screwdriver #2 Philips Head screwdriver Stranded 18 AWG wire for power connection Stranded 12 AWG wire for ApexPlus ODU and OMU ground connections Wire Insulation strippers for ground and power wire Terminal crimpers for ground and power wire Trango Systems, Inc. ApexPlus User Manual Rev 3.0 63 Power Supply The ApexPlus requires a ‐48 Volt power supply, however other power supplies will work as long as the voltage at the radio unit is between ‐40 and ‐72 VDC. Trango recommends two power supplies 1. ‐48 VDC, 1U rack mount power supply (part# P‐SUPPLY‐1U‐48) ‐ Powers up to four ApexPlus units 2.
‐48 VDC universal desktop power supply, 1.6 A (part# PSUPPLY‐WM‐48L) ‐ Powers one ApexPlus unit. Each unit is supplied with a two position terminal block that plugs into the ApexPlus main access panel. The wiring of the terminal block should be done as shown below. The cabling used should be either coaxial (LMR 195 or Equivalent) or two wires of a size no smaller than 18 AWG. If individual wires are used, the wires should be twisted together to reduce susceptibility to noise. At least one turn per inch is recommended. NOTE: Ensure that only a ‐48 Volt Supply is used and that the wiring is correct. If a +48 VDC supply is used and the Earth ground is wired to the negative terminal shown in the figure, permanent damage to the unit may occur. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 64 Coax Cable Center Conductor (‐48 VDC) Coax Cable Shield (Ground Return) ‐48 VDC Ground Return
Figure 15‐ 48 VDC Power Connector using Coaxial Cable and 16 AWG Cable In the figure above, the Power can be connected in two ways, Power‐over‐Ethernet or Direct DC Power as described in the sections below. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 65 Grounding Diagram Grounding of the Ethernet cable should be done at the base of the tower using the Terminal Block on the PoE Injector/Surge Suppressor Box. This applies to direct power or PoE powered installations using copper Ethernet. The surge suppression built into the PoE‐ GigE‐48 will help protect network equipment inside the shelter from damage. A Ground wire of AWG 12 or larger should be used and grounded to an Earth grounded tower leg or Bus Bar before entry into the shelter. Figure 16 shows the overall ground design. Figure 16 PoE Based Grounding Diagram Trango Systems, Inc. ApexPlus User Manual Rev 3.0 66 PoE Based Installation This section covers installation when powering the unit through Power Over Ethernet (PoE) using a single or multiple Cat5e or Cat6 Shielded Twisted Pair (STP) Cable is desired, with copper or fiber traffic interfaces. The POE‐GIGE‐48 is shown in the Figure below: Figure 17 POE‐GIGE‐48 The PoE Power Injector POE‐GIGE‐48 can be connected to either of the two copper Ethernet ports: 1. Out‐of‐Band Management Port: Always use a shielded Cross‐Over Ethernet cable when connecting the out‐of‐band Management Port to a COMPUTER (see Figure 6). 2. Data Port: Always use a shielded Straight‐Through cable when connecting the Data Port to a HUB, SWITCH, or ROUTER IMPORTANT INFORMATION ON THE APEXPLUS PoE 1) The PoE is non‐standard and will not support 802.3af due to the high current requirements of the radio unit. 2) The total length of the Ethernet cabling from network switch to ApexPlus unit cannot exceed 100 meters. This length is the sum of the length of cable from the PoE injector to the ApexPlus unit PLUS the length of cable from the PoE Injector to the network switch. 3) Since the PoE Requires ALL 8 conductors AND the shield which acts as the ground, it is critical that a. ONLY shielded Twisted Pair (STP) Cat5e or Cat6 cabling be used Trango Systems, Inc. ApexPlus User Manual Rev 3.0 67 b. Shielded connectors are used with the shield crimped properly to the cable shield wire. c. All 8 conductors are wired. 4) The PoE Has an “ODU ON” LED that will illuminate solid green when the connection to the ApexPlus is consuming the normal operating current with an input voltage from ‐40 to ‐72 VDC. The LED will flash or turn off if the current is below roughly 700 mA, indicating a faulty cable, power supply, or ApexPlus If any of the above conditions are not met the PoE function may not work correctly Earth Ground Clamp 10/100 Mgmt + 48 VDC to Apex Plus Mgmt Port 10/100/1000BaseT Data Port + 48VDC to ApexPlus Data Port Mgmt Port Fuse
Data Port Fuse T1/E1 Port to TDM Network Data Port to Network Switch/Router 10/100 Mgmt Port To Switch/Router ‐48 VDC Input for Data Port ‐48 VDC Input for Mgmt Port
Spare Fuse
Management Side Cable Entry Figure 18 POE‐GIGE‐48 Internal wiring Data Port Cable Entry Trango Systems, Inc. ApexPlus User Manual Rev 3.0 68 PoE Based Installation (1+0) In‐Band Management Only The wiring for basic 1+0 installation with In‐Band Management is shown below. Use this configuration if only one cable is being run from the network switch to the unit and it must carry the data, management traffic, and power. Master Ground Bar
Wall Mount Power Supply
PoE GigE 48
GROUND
Must be
STP CABLE
with shielded
connectors at
both ends
T1/E1 PORT MGM PORT
DATA PORT
SPARE FUSE
3.5A/125VAC
ApexPlus Interface Panel
(Port Plate)
OUTPUT
GND
-48
Volt
To AC
Power Outlit
Data + Management GigE
(Cat5e /straight STP)
1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
10/100/1000BaseT Ethernet Switch
Figure 19 1+0 / IBM PoE Wiring Trango Systems, Inc. ApexPlus User Manual Rev 3.0 69 In‐Band and Out‐of‐Band Management, Single power Supply The wiring for basic 1+0 installation with Out‐of‐Band Management is shown below. Use this configuration if two cables can be used, one for Data and power, and one for management of the radio. The power may also be applied on the management side only if desired with no change in function. Although it is possible to run the unpowered Ethernet cable directly to the Radio without going through the PoE‐GigE‐48, no surge protection would be present on the unpowered cable. Both the management and data are protected from surges if wired as shown below. Figure 20 1+0 / OBM PoE Wiring Trango Systems, Inc. ApexPlus User Manual Rev 3.0 70 In‐Band and Out‐of‐Band Management, Dual Power Supply The PoE GigE‐48 has separate physically isolated and fused circuits to allow powering the same ApexPlus with two separate redundant power supplies as shown below. Both IBM and OBM can be used in this configuration.
Master Ground Bar
Wall Mount Power Supply
(Redundant)
Wall Mount Power Supply
PoE GigE 48
GROUND
Must be
STP CABLE
with shielded
connectors at
both ends
T1/E1 PORT MGM PORT
DATA PORT
SPARE FUSE
3.5A/125VAC
OUTPUT
GND
OUTPUT
-48
Volt
GND
-48
Volt
To AC
Power Outlit
To AC
Power Outlit
ApexPlus Interface Panel
(Port Plate)
Data GigE (Cat5e /
straight STP)
Manangement
10/100 (Cat5e /
straight STP)
1
2
3
4
5
6
7
8
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
9
10/100/1000BaseT Ethernet Switch
Figure 21 1+0 PoE Redundant Wiring Trango Systems, Inc. ApexPlus User Manual Rev 3.0 71 PoE Based Installation (1+1 Hot Standby) The installation of the 1+1 hot Standby is similar to the 1+0 installation, except the installation is repeated using a second PoE‐GigE‐48 and separate power supply for the second standby unit which is mounted on the combiner. Although it is possible to use a single PoE‐GigE‐48 to support both the active and standby unit in the 1+1 configuration, it is recommended to use two PoE‐GigE‐48 PoE Injectors. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 72 Direct Power Based Installation (1+0) This section covers installation when powering the unit through the direct ‐48 Volt DC port and using the Copper or Fiber traffic interfaces is desired. The primary benefit of direct power is that no surge suppression is required on the traffic interface since fiber can now be used, and the distance to the network can be longer due to the long lengths supported by the fiber and direct power wiring. The 100 meter limitation still applies for any copper Ethernet cabling. The actual length of the power cable run depends on the wire gauge being used. It is recommended that the voltage be measured at the radio terminals after power‐on of the OMU and ODU to ensure it does not fall below the minimum required voltage. For long runs of Power, coaxial cable is recommended in conjunction with surge suppressors to reduce the risk of voltage spikes causing damage to network equipment. The Direct Power interface on the front panel is shown below: Figure 22 Direct Power Wiring Direct Power Based Installation (1+1 Hot Standby) The installation of the 1+1 hot Standby is similar to the 1+0 installation, except the installation is repeated for the second standby unit which is mounted on the combiner. The CBLDAT‐RIU4 is connected between the units. .
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 73 ApexPlus ODU Installation on Antenna The ODU portion of the ApexPlus utilizes a slip fit connection that makes installation simple. The ODUs are all designed to mount to a circular waveguide antenna or combiner with the exception of the 6 GHz models. For 7 to 40 GHz models, simply rotating the ApexPlus will change the antenna polarization being used. Antenna O‐
Ring Seal ApexPlus Waveguide
Antenna Waveguide port Figure 23 Antenna to ApexPlus Slip Fit Waveguide connection After installing and securing the antenna the Apex Plus unit can be installed directly on the back of the unit. First, determine which Antenna polarization will be used and ensure that the polarization indicator is at the top of the unit. For vertical polarization the “V” should be at the top of the unit, and for horizontal polarization the “H” should be at the top of the unit. Polarization Indicators – The letters “H” and “V” are die cast on the OMU housing perimeter to assist in mounting the ApexPlus to the antenna in the correct polarization. The letter that is at the top will always indicate the antenna polarization being utilized, for all models. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 74 “H” polarization indicator Figure 24 Polarization Indicator Cover the antenna O‐ring with silicone grease per the Antenna manual. Failure to do this may result in a damaged O‐ring and subsequent damage to the antenna or radio. Gently slide the ApexPlus unit onto the antenna and clip the four spring loaded latches to the antenna clips as shown below. The latches should be very snug and “click” into place. If there is difficulty closing the latches, then check the waveguide for debris or foreign matter around the perimeter. Secure the latches that have eyelets with locks if desired. Latch with Eyelet Figure 25 Latches For AP1‐06‐xxxx‐zz models, both the antennas and radios use a rectangular waveguide opening on the same slip‐fit design. The standard polarization is supplied as Vertical. To Trango Systems, Inc. ApexPlus User Manual Rev 3.0 75 change the polarization, the antenna must be changed from vertical to horizontal by rotating either the antenna or the antenna waveguide port Cable Installation ApexPlus is supplied with the following components to seal the cable entry port from weather. Port Cover and 2 Stainless Steel Captive Screws NPT ¾” Strain Relief with 2 position cord Figure 26 Port Sealing Components After the Ethernet/Power/Fiber cables are prepared, they should be run through the Cord Grip and port cover and then connected to the ApexPlus ports:
Figure 27 STP Cables installed on Unit Trango Systems, Inc. ApexPlus User Manual Rev 3.0 76 Tighten the two port cover screws using a flathead screwdriver. The screws should be tightened to 8 lb‐in to ensure sealing pressure on the silicone gasket around the ports inside. Figure 28 Detail of the Stainless Steel Thumbscrew Run the Ethernet cables through the strain relief as shown below. The rubber grommet may need to be cut on the edges to fit cables that have already been terminated with RJ45 connectors. If required, use straight blade to carefully cut the grommet. Strain Relief Body Strain Relief Grommet Strain Relief Outer Nut Figure 29 Strain Relief Exploded View Trango Systems, Inc. ApexPlus User Manual Rev 3.0 77 Snug the strain relief body into the port cover as shown below ‐ Teflon tape may be used on the threads but is not necessary. Slide the grommet into the body and tighten the outer strain relief nut. The cables should be held tight by the rubber after the strain relief is tightened. Note – A clicking sound may be heard during tightening which is normal.
Silicone Strain Relief Installed Figure 30 Strain Relief Installed The OMU ground lug is shown below (next to the OMU to ODU cable). Use the ApexPlus ground wire kit to attach this point and the ODU ground lug to the grounded tower leg where the unit is installed.
Figure 31 Ground Lug on OMU Trango Systems, Inc. ApexPlus User Manual Rev 3.0 78 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 79 Antenna Installation Antennas are typically installed and are coarse aligned using either visually or with third party equipment. Alternatively, some operators prefer to install the radio equipment onto the antenna prior to installing the antenna on the rooftop or tower. Consult the specific antenna manual for the antenna being used for detailed installation instructions. The Link Configuration section covers the alignment of the antennas. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 80 7.0 Link Configuration This section describes the step by step process of configuring a link and making sure it is working properly before installing and putting live traffic on the system. This section covers basic link establishment for a single link. This setup may be done on the bench or in the field. It is highly recommended that the basic link setup be done on the bench to avoid problems when installing the equipment. Special bench test setups that provide mounting and fixed or variable attenuation between the RF ports of the units can be obtained from Trango for this purpose. All steps given should be performed on both ends of the link. IMPORTANT NOTE: If the link was factory preconfigured at Trango before shipment, this section can be skipped since the proper settings are already in place inside the radio units. Only the IP addresses need to be changed and the Opmode needs to be enabled at both ends. See the Quick Setup Guide for more information. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 81 Web Based Configuration Web Based 1+0 Setup The Web interface is the most commonly used way to setup a link. A step by step guide is shown below. To access the Browser interface from the Out‐of Band management port, simply connect to the unit using Ethernet cabling, open a web browser and enter the IP address of the radio. The default IP address is 192.168.100.100 Figure 32 Web Interface Login Step 1: Enter the username and password A login window will pop up, requiring the user to enter username and password (See Figure 33). There are two web interface access levels, view and config, just like the command line interface. View level allows only viewing link parameters while config level allows changing link parameters. To enter View level, type the default user name and password (user: admin, password: trango) and click OK. Figure 33 Web Login with Password Trango Systems, Inc. ApexPlus User Manual Rev 3.0 82 Once the user name and password are authenticated, the View level Version page will be displayed as shown below: Figure 34 System Status‐ Version Page Step 2: Set the IP addresses a. Click on the “Config“ button in the lower left and sign into the config level web interface at make changes. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 83 b. Click on the Network Settings folder and IP/IBM configuration page. Set the IP address, Subnet, and Gateway to the address that is desired for the Out‐of‐band Management Port. Click Submit. At this point the Web session will terminate and the operator must login again using the new IP address. At this point the Web session will terminate and the operator must login again using the new IP address. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 84 Step 3: Set the Radio link parameters All the parameters should match those submitted and approved by the licensing agency, and typically these will have already been programmed by the factory. c. Set the Odupower to “On” if it is not already on. d. Turn the Opmode to “Off” if it is not already off. e. Set the TX frequency, bandwidth, modulation and transmitter power, then click Link Setup. In general, the Freq Duplex does not need to be changed unless a non‐standard spacing is being used. f. After both ends of the link are setup, turn the opmode button “on” to establish the link. Do not adjust the Failover settings at this time even if 1+1 operation is desired. A normal working link must be set up first before 1+1 is enabled. See the Section on setting up 1+1 for detail on this. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 85 Figure 35 Link Setup Page The link should now be established between the two sides. The Active Link indicators will turn green and the RSSI and MSE levels will change according to the link distance or attenuation used (if testing in a lab environment) Click the Save Config button at the lower left of any webpage – This must be done on both sides of the link. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 86 Web Based 1+1 Setup The 1+1 Setup is an extension of the basic 1+0 setup. 1+1 hot standby utilizes two ApexPlus units connected to a combiner to allow sharing of an antenna at each end of the link. One of the units at each end is the main (active) unit and the other unit is in standby, which means that it is ready to take over should the active unit fail. This section assumes that the physical installation has been done already. Return to the Installation section and connect the units in a 1+1 configuration if required. 1) Follow the steps for 1+0 on the main link as described above with the backup units turned off (‐48 VDC disconnected). 2) Turn the standby radio units on, but ensure the opmode is off on both to avoid disturbing the active link. Default opmode is off at time of shipment. 3) On the Active Link Config Page select the Failover Mode with Port Off button: Figure 36 Failover Mode Set 4) Repeat for the Active link other end unit. 5) The display for the Link status at the top of the page should change to show both Active and Standby units “Green” for all 4 units. 6) The system is now setup in 1+1 mode. If the main link fails, the ports will be shut down on the main link and the traffic will flow through the standby link, allowing connected switches to re‐route the traffic. 7) Click the Config Save button at the lower left of any webpage – This must be done on both sides of the link. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 87 Adaptive Coding and Modulation (ACM) (Optional) Enabling ACM permits configuration of the MSE Improve and Degrade thresholds. It is recommended to use the default values for best performance. Select the “On” button and then click on the submit button to make the change if ACM is desired. Figure 37 ACM Setup Trango Systems, Inc. ApexPlus User Manual Rev 3.0 88 Automatic Transmit Power Control (ATPC) (Optional) Enter the max power levels for each modulation level and enable ATPC to increase system gain during channel fading conditions. The target RSSI should be set to match the normal operating RSSI based on the path calculation. The system will attempt to maintain the target RSSI by sending requests to increase or decrease the transmit power to the other end of the link. When the max power levels are set to the same value for all modulations, it is only recommended to use ATPC for extremely short links where the max power would be higher than the max allowable receiver input. Figure 38 ATPC Setup/ RPS /Telnetd/ tftpd Trango Systems, Inc. ApexPlus User Manual Rev 3.0 89 Command Line Interface (CLI) Based Configuration CLI Based 1+0 Configuration This section covers all the basics that are normally required for setting up the link using either the telnet, SSH, or serial COM port to access the units. Step by step instructions with session examples are given. The CLI interface has more functions available than the Web Interface. Simply type the “?” to see a list of available commands. Step 1: Connect to Each Unit via one of the CLI interfaces In all the examples given, telnet was used, but the login procedure is similar for each. To log into each ApexPlus units using the default IP address of 192.168.100.100. Use the windows telnet program or any other telnet client program. When prompted for the Login enter admin and for password, enter trango. The Trango Systems command line interface application should respond as follows: Microsoft Windows XP [Version 5.1.2600]
(C) Copyright 1985-2001 Microsoft Corp.
C:\Documents and Settings\user>telnet 192.168.100.100
CLI login: admin
Password:
Trango System:
TrangoLINK ApexPlus Command Line Interface v1.0.0
When logging into the radio unit, the operator always enters the (CLI‐view)# node, from which only status of the system can be seen. To make changes to system settings, the operator must enter the (CLI‐config)# node of to allow changes to the system to be made. Type the command config and the password trango. The password can be changed later. (CLI-view)# config
Password:
Step 2: Change the Out of Band (OBM) Management IP Address Trango Systems, Inc. ApexPlus User Manual Rev 3.0 90 It is recommended to change the IP address on both ends of the radio first, before installing the link to ensure that no problems will be encountered accessing the units in the field from the destination network subnet To change the IP address of the system, first check the ip settings using the ip command. (CLI-config)# ip
IP Address:
10.14.1.41
Subnet Mask:
255.255.0.0
Gateway IP:
10.14.1.1
ETH0 MAC:
00:01:de:87:cd:ac
ETH1 MAC:
00:01:de:87:cd:ad
Next, change the IP address and subnet mask. The system will not be responsive after the change. Reconnect to the ApexPlus using the new IP address. CLI-config)# ipconfig ip 10.14.1.41 255.255.254.0
IP Address:
10.14.1.41
Netmask:
255.255.254.0
SUCCESS
After re‐connecting, change the gateway address as necessary. (CLI-config)# ipconfig gateway 10.14.0.1
Gateway IP:
10.14.0.1
SUCCESS
Confirm that the changes are made: (CLI-config)# ip
(CLI-config)# ipconfig
IP Address:
Trango Systems, Inc. 10.14.1.41
ApexPlus User Manual Rev 3.0 91 Subnet Mask:
255.255.254.0
Gateway IP:
10.14.0.1
ETH0 MAC:
00:01:de:87:cd:ac
ETH1 MAC:
00:01:de:87:cd:ad
Step 3: Turn the ODU Section of the radio on Type odupower on to apply power to the Radio section of the unit. After the CLI returns the status of “on”, enter model to show the models, serial numbers, TR spacing and transmit frequency range of the unit. (CLI-config)# odupower on
ODU Power enable:
on
SUCCESS
(CLI-config)# model
OMU Model:
AP-OMU-1
OMU Serial ID:
8900004
ODU Model:
HP2-23-1232-1A
ODU Serial ID:
C 2010DEC80001
Tx Freq Min:
21200.00
Tx Freq Max:
21500.00
Freq duplex:
1232.00 (MHz)
Step 4: Set the Transmitter and Receiver Center frequency The center frequency must be within the min and max shown in the model command and must be at least ½ of the occupied transmitter bandwidth away from the limits for proper operation. Enter the transmit frequency in MHz (the resolution of the frequency is .250 MHz). The receive frequency will automatically be programmed as follows: For A models, RX Freq = TX freq + Freq Duplex. For B models, RX Freq= TX Freq – Freq Duplex. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 92 In some cases the Freq duplex can be changed, but typically this will not be necessary. Changing the Freq duplex will automatically change the RX frequency. First set the local end transmit frequency: (CLI-config)# freq 21472
Tx Freq:
21472.00 (MHz)
Rx Freq:
22704.00 (MHz)
Freq duplex:
1232.00 (MHz)
Next, Set the far end transmitter frequency (separate session with the other radio) (CLI-config)# freq 22704
Tx Freq:
22704.00 (MHz)
Rx Freq:
21472.00 (MHz)
Freq duplex:
1232.00 (MHz)
If the system has been installed and the far end transmitter is also on the link can be checked using the linktest command (CLI-config)# linktest
LOCK
1>
1
RSSI
MSE
-45.00
-36.70
BER
0.00E+00
Step 5: Enable Adaptive Coding and Modulation (ACM) (Optional) If ACM is desired, the acm enable command should be used on both ends of the link. IMPORTANT: After the ACM is enabled after initial link establishment, the speed command must be reissued. (CLI-config)# acm enable on
ACM enable:
Trango Systems, Inc. on
ApexPlus User Manual Rev 3.0 93 SUCCESS
The two steps above must be done on both ends of the link, starting with the unit that does not have output band management or which relies on the ApexPlus IBM connection for management
Step 6: Set the Speed and Modulation The speed setting may require a license key if the resulting payload speed is above 100 Mbps. (CLI-config)# speed
Modulation:
128QAM
Bandwidth:
20.00
Symrate:
17.42
Speed:
111.00
Step 7: Enable the Transmitters Turn opmode on on both ends of the link. This enables the transmitter on the unit. After the opmode is turned on, the TX frequency cannot be changed unless opmode is turned off again. (CLI-config)# opmode on
Opmode:
on
SUCCESS
Step 8: Verify the link is working Run the linktest command to confirm that the link is running properly after enabling ACM. Notice that the Tx and Rx modulation levels are now shown. Now, if the link conditions degrade due to rain fading, either the Tx or Rx may downshift during the fade event. Running the linktest command again will show the lower modulation such as 64QAM, 32QAM, etc. for Tx or Rx. The RSSI will also likely change for rain fading, but may remain unchanged if the link degradation is due to multipath. The modulation/RSSI will automatically return to the set value once the fading condition has passed. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 94 (CLI-config)# linktest
LOCK
1>
1
RSSI
MSE
BER
-38.00
-35.00
0.00E+00
Tx
128QAM
Rx
128QAM
Step 9: Save the configuration Run the config save command to save all the settings that were changed into non‐
volatile FLASH memory. If a power interruptions should occur, the link should re‐
establish itself after the interruption is over.
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 95 CLI Based 1+1 Hot Standby Configuration This section assumes that the physical installation has been done already. Return to the Installation section and connect the units in a 1+1 configuration if required. Steps to configure 1+1 Hot Standby: 1) Follow the 1+0 configuration section to establish a link between the two main ends of the link, with the second pair of radios turned off. The antennas should be aligned at this point. 2) For both ends of the main link: a. Set the failover function to ON using the failover command . b. Set opmode on . c. Set default_opmode on. d. Save the configuration using config save e. Power both ends of the link down. 3) Bring the second link (Standby) up using the same configuration as the main pair. a. Set the failover function to ON using the failover command on both ends of the standby link. b. Save the configuration using config save c. Power both ends of the link down. 4) Connect the redundancy cable CBLDAT‐RIU4 between the two units. 5) Power both main link up 6) After the link is established, power up the second link. 7) After the election period expires, the two units at each end (active and standby) should sync up with the proper utype and configuration settings. 8) Verify by running the failover command and observing the status. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 96 Antenna Alignment After Basic Setup of the link, the antennas can be aligned. Aligning narrow beam width (< 2º) over long distances can be a difficult process without the proper equipment, patience, and a careful process. Using a GPS compass and the Path Analysis to establish a crude azimuth and elevation, the installation crew can mount the Antenna Assembly on the supporting structures at each end of the link. Once the antennas are installed and a rough antenna alignment has been established, then the fine alignment process can begin at one end of the link (typically the site with the smaller antenna). Once one side is aligned to achieve best RSSI, MSE, and BER then the operator can adjust the other side to improve the link. Alignment can be done using the linktest command from the command line interface, or the voltage indication from the BNC connector on the ODU. Figure 39 BNC Connector for RSSI Voltage Run the linktest command while aligning the antenna and look for the MSE to improve (a higher negative number) while adjusting. When the lock status changes to 1, you may fine tune the alignment with the LED display Antenna Alignment Procedure 1.
Ensure that both sides of the link are configured correctly. 2.
Connect to the management port of the ApexPlus. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 97 3.
Login to the end of the link that is being aligned. 4.
Run linktest 99 command while adjusting the antenna(s), and monitor the BNC output voltage until the expected voltage/RSSI level is reached. The voltage at the BNC will range from 0.1 Volts at ‐90 dBm input level to 4.5 Volts at ‐20 dBm input level. Use a voltmeter and CBLDAT‐RSSI to monitor the voltage while adjusting the antenna. The following equation can be used to determine the RSL within 3 dB accuracy RSL (dBm) = 15.77 x VBNC ‐91.58 Below is a table showing the voltage to RSL for convenience. Voltage (Volts)
0.1
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
2.5
2.75
3
3.25
3.5
3.75
4
4.25
4.5
RSSI (dBm)
‐90
‐87.6
‐83.7
‐79.8
‐75.8
‐71.9
‐67.9
‐64
‐60
‐56.1
‐52.2
‐48.2
‐44.3
‐40.3
‐36.4
‐32.4
‐28.5
‐24.6
‐20.6
Table 12 RSSI to Voltage Conversion 5. Once satisfied with the RSSI reading, tighten down the antenna in the optimum position. 6. Replace the sealing cap on the BNC connector and tighten until it clicks into place. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 98 CLI Common Task Reference Setting up the In‐Band‐Management (IBM) Trango pre‐configures the links with IBM already set up and enabled, however it will typically be necessary to change the IBM IP addresses used to fit the application management network and if management across the network is desired, a VLAN must be setup on the attached switches. This section covers the setup of the IBM. Display the IBM settings. In the example below the IBM is off. (CLI-config)# ibm
IBM Enable:
off
IBM Vlan ID:
4085
IBM Port:
ge1-copper
IBM IP address:
172.16.1.1
IBM Netmask:
255.255.0.0
SUCCESS
Enable IBM using the settings preloaded. (CLI-config)# ibm enable on
IBM enable:
on
SUCCESS
Change the IBM IP address and subnet mask. Each end of the link should have a different IP address, and in the case of multiple daisy chained links , the IPs should all be different. (CLI-config)# ibm ip 172.16.1.2 255.255.255.0
IBM IP Address:
IBM netmask:
Trango Systems, Inc. 172.16.1.2
255.255.255.0
ApexPlus User Manual Rev 3.0 99 SUCCESS
Verify the settings are correct. (CLI-config)# ibm
IBM Enable:
on
IBM Vlan ID:
4085
IBM Port:
ge1-copper
IBM IP address:
172.16.1.2
IBM Netmask:
255.255.255.0
Verify the connection to the other end of the link by entering the debug node and using the ping command inside the ApexPlus. In the example, the other end of the link has an IP address of 172.16.1.1. (CLI-config)# debug
Ping the other side of the link using the ping command from within the debug node of the radio. # ping 172.16.1.1
PING 172.16.1.1 (172.16.1.1): 56 data bytes
64 bytes from 172.16.1.1: seq=0 ttl=64 time=6.672 ms
64 bytes from 172.16.1.1: seq=1 ttl=64 time=1.001 ms
64 bytes from 172.16.1.1: seq=2 ttl=64 time=0.979 ms
--- 172.16.1.1 ping statistics --3 packets transmitted, 3 packets received, 0% packet loss
round-trip min/avg/max = 0.979/2.884/6.672 ms
Return to the command line interface using the cli command. Upon returning from the debug prompt, the system will be in the view node, so the user must log into the config node if any further changes are required. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 100 # cli
Trango System:
TrangoLINK ApexPlus Command Line Interface v1.0.0
Return to the config node using the config command (CLI-view)# config
Password:
Capacity License Activation Activate the traffic capacity license if needed. License keys are typically installed at the factory prior to shipment. Should the operator wish to re‐enter the license keys, use the license command as shown below (CLI-config)# license 2 <alphanumeric key>
License:
License 2
SUCCESS
Automatic Transmit Power Control (ATPC) Configuration (optional) Configure the Automatic Transmit Power Control (ATPC) if required. ATPC is typically only required if the the link is so short that the max transmit power cannot be used due to receiver overload, or for regulatory reasons. First check the ATPC status. If the ATPC is off then the ATPC can be enabled using the atpc enable on command. In the example below the max power is currently 19 dBm (CLI-config)# atpc
ATPC Enable:
on
ATPC Step Size:
1
ATPC Max Power:
19.00
Next, set the ATPC max power based on the highest modulation that will be used. In the example below, the highest transmit power that will be used is +17 dBm, so the atpc max_power is set accordingly. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 101 (CLI-config)# atpc max_power 17
ATPC max power:
17.00
SUCCESS
(CLI-config)# atpc
ATPC Enable:
on
ATPC Step Size:
1
ATPC Max Power:
17.00
Next, set the target receiver level that will be used to control the far end transmitter power. If the RSSI is too high, then the ATPC software will send an ATPC power down command to the other end of the link. The targetrssi must be set on both ends of the link, just as the ATPC max power. The ATPC software will stop sending commands to the other end of the link when the RSSI is inside + / ‐ 2 dB of the target rssi set level. (CLI-config)# targetrssi
Target RSSI:
-45.00
(CLI-config)# targetrssi -40
Target RSSI:
-40.00
SUCCESS
Check Ethernet and RF port Statistics Run the status port command This command shows the current Ethernet port statistics and to provide confirmation that the connection to the network equipment is set up properly. The system default is auto‐negotiate. The ge1 and ge2 are mapped to the copper and SFP data ports respectively, and the ge0 port is the interface from the internal switch inside the ODU to the modem. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 102 The ge0 statistics are typically not monitored and are made available for troubleshooting purposes only. The RF counters indicate the statistics for the receive port and the transmit port. The Octet/Packet counts on the RF counters may be slightly higher due to internal messaging between the two ends of the link for internal link management, and again they are primarily for troubleshooting purposes and do not need to be monitored continuously. Monitoring the RF drop counts is useful for determining if errors are occurring over the wireless portion of the link. The port rate and port utilization (percent) are also useful for monitoring since they can indicate a link running at capacity. These two metrics account for the sum of all the Ethernet ports being used. (.72-config)# status port
<====================== Ethernet Counters ======================>
Port:
ge1
ge2
ge0
Enable:
on
on
on
Status:
on
off
on
Duplex:
full
full
full
Speed:
1000
1000
1000
In Octets:
2598150077
0 1168476128
In Ucast Pkt:
1852535353
0 3364786732
In NUcast Pkt:
0
0
0
In Port Rate:
347
0
286
In Port Util:
34
0
28
Out Octets:
4087505152
0 1939268960
Out Ucast Pkt:
3352202931
0 3565551594
Out NUcast Pkt:
0
0
0
Out Port Rate:
269
0
221
Out Port Util:
26
0
22
CRC Errors:
0
0
0
CollisionError:
0
0
0
<======================== RF Counters ==========================>
IN
OUT
Total Octets:
1872251772
3582899144
Total Pkt:
4133016647
4158172838
Total Drop Pkt:
0
N/A
Port Rate(Mbps):
296
229
Port Util(per):
81
62
Run the status clear command After the link has been established and the Ethernet interfaces are running properly, the counters may all be cleared. This is typically done just prior to the link validation phase in which a fixed amount of traffic or packets are passed over the link over a period of Trango Systems, Inc. ApexPlus User Manual Rev 3.0 103 time to ensure no drops occur. The status clear command will clear all port counters and the BER counters. (CLI-config)# status clear
Run the syslog clear command Before deployment it is a good idea to clear the syslog so that only events after the link was commissioned are recorded. Run the syslog clear command. (CLI-config)# syslog clear
(CLI-config)# syslog
Current 0:19:24:25.990
View the model information using the model command (CLI-view)# model
OMU Model:
OMU Serial ID:
ODU Model:
ODU Serial ID:
Tx Freq Min:
Tx Freq Max:
Freq duplex:
AP-OMU-1
8900004
HP2-23.00-1232-0A
C 2010DEC80001
21200.00
21500.00
1232.00 (MHz)
Enable Traps (Optional) Traps can be used to notify external network monitoring devices that a threshold parameter has been crossed. Thresholds re available for the following: RSSI
MSE
BER
FER
OMU_TEMP
ODU_TEMP
OUT PORT UTILIZATION (percentage of max available)
IN PORT UTILIZATION (percentage of max available)
LINK DOWN
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 104 If thresholds have been set and an SNMP trap assigned as an action, the crossing of the threshold will generate a trap. The current trap information using the trap command. The current trap manager IP addresses are shown along with their individual status: (CLI-config)# trap
IP
Trap 1:
0.0.0.0
Trap 2:
0.0.0.0
Trap 3:
0.0.0.0
Trap 4:
0.0.0.0
Trap 5:
0.0.0.0
Enable
off
off
off
off
off
Set the trap 1 manager IP address using the trap ip command – repeat for additional trap manager ip addresses: (CLI-config)# trap ip 1 10.14.1.5
IP
Trap 1:
Enable
10.14.1.5
off
SUCCESS
Enable the trap number 1 using the trap enable 1 on on command – The trap will be enabled and the status shown: CLI-config)# trap enable 1 on
IP
Trap 1:
Enable
10.14.1.5
on
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 105 8.0 Troubleshooting This section provides troubleshooting advice for problems that may be encountered during setup and normal operation of the system. Symptom: No Link (Lock = 0 during linktest) 1) TX Frequency must EXACTLY match the RX frequency on the remote side. Type freq command from the CLI to view. Verify that the frequencies used match the regulatory body (FCC or equivalent) approved frequencies. 2) Opmode is off. Run opmode command to view, and run opmode on to enable. If the unit was rebooted and the default opmode is not on, the unit will come back on but the opmode will be off. To prevent, run default_opmode on command and config save. 3) Are the frequencies configured correctly on each radio (TX and RX)? High frequency on the “B” side and low frequency on the “A” side.. 4) Is the ApexPlus unit installed properly on the remote mount (remote mount applications only)? The radio unit will only operate in a single orientation on the remote mount. Follow the directions on the remote mount to ensure correct installation. The arrows on the Remote mount must be aligned with the “V” on the ApexPlus unit. 5) Are both ApexPlus units mounted on the same polarization? ApexPlus units must be mounted with matching polarizations at each end of the link. If one side is mounted on the antenna differently than the other side, the link will not lot or the signal level will be 20‐30 or more dB lower than expected. 6) IF ACM is being used, ACM may not be enabled on both ends of the link. Enable the ACM and reset the speed on each end. The speed must be set the same on both ends. MSE is too high and/or bit errors are showing when running linktest Trango Systems, Inc. ApexPlus User Manual Rev 3.0 106 NOTE: MSE= ‐32 dB or lower is typical for 256 QAM, ‐29 is a worse number and is not typical 1) Is the transmitter power set too high for the current modulation being used. Consult the license information to verify that the power level is no higher than the maximum allowed for the highest modulation that will be used. 2) Target RSSI setup may be incorrect. It is best to set the target RSSI as high as possible without overdriving the receiver for the most robust operation. Setting the target RSSI too close to the RX sensitivity threshold will compromise the link integrity. 3) Are both ApexPlus radios mounted on the same polarization? ApexPlus radios must be mounted with matching polarizations at each end of the link. If one side is mounted on the antenna differently than the other side, the link will not lock or the signal level will be 30 or more dB lower than expected. 4) Is the ApexPlus unit installed properly on the remote mount (remote mount applications only)? The radio unit will only operate in a single orientation on the remote mount. Follow the directions on the remote mount to ensure correct installation. The Arrow on the remote mount must line up with the “V” on the ApexPlus unit. 5) Presence of microwave transmitters on same frequency (uncommon): To check for possible interference from other licensees, turn off the opposite end transmitter and run the rssi command. The signal level should be ‐90 or lower. The level should be steady within a dB or so. Receive Signal Level is too low 1) Target RSSI setup may be set incorrectly. It is best to set the target RSSI as high as possible without overdriving the receiver for the most robust operation. Setting the target RSSI too low will result in a signal level lower than what is expected if ATPC is enabled . 2) Reported RSSI more than 3 dB off the expected RSSI: There may be a alignment problem with the antenna, especially if both sides of the link show the same symptom.. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 107 Solution: Realign the antenna(s). Opmode must be on at the remote side of the link to do alignment of the local side. Ensure that ATPC is off.. 3) Are both ApexPlus radios mounted on the same polarization? ApexPlus radios must be mounted with matching polarizations at each end of the link. If one side is mounted on the antenna differently than the other side, the link will not lock or the signal level will be 30 or more dB lower than expected. 4) Is the ApexPlus unit installed properly on the remote mount (remote mount applications only)? The radio unit will only operate in a single orientation on the remote mount. Follow the directions on the remote mount to ensure correct installation. The Arrow on the Remot mount must line up with the “V” on the ApexPlus unit. RF Link is good but packet loss is occurring: 1) Verify the duplex and speed settings in the Ethernet port are correct (100 or 1 Gbit) and match the connected equipment, and that no CRC errors on the port are occurring. 2) Verify that the Ethernet ports are connected properly. The ApexPlus family of Radios are port mapped, meaning that the traffic going into Ethernet Port 1 on the local side will only appear at port 1 of the remote side, local side port 2 traffic will appear on the remote side port 2, etc.. 3) Check the Ethernet cables for correct wiring. If 1000BaseT is being implemented, Cat6 cable should be used. Ensure that the cable is shielded and proper grounding is applied to the RJ45 connector. No Radio Management connection over the link 1) Verify the In‐Band management is set up properly ‐ Check to see if the IP configuration is correct, the VLAN ID is set and matches on both ends, and that IBM is enabled. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 108 Appendix A – Command Line Interface Reference This Appendix provides a standalone guide to the commands available through the Telnet, SSH, and console port of the ApexPlus. Command Keying Overview Key Functions Tab ‐ Autocomplete Completes a partial command name entry. When you enter a unique set of characters and press the Tab key, the system completes the command name. If you enter a set of characters that could indicate more than one command, the system beeps to indicate an error. Enter a question mark (?) immediately following the partial command (no space). The system provides a list of commands that begin with that string. Del or Backspace Erases the character to the left of the cursor. Return At the command line, pressing the Return key performs the function of processing a command. At the –More‐‐ prompt on a terminal screen, pressing the Return key scrolls down a line. Space Bar Allows you to see more output on the terminal screen. Press the space bar when you see the More prompt on the screen to display the next screen. Left Arrow Moves the cursor one character to the left. Right Arrow Moves the cursor one character to the right. Up Arrow Recalls commands in the history buffer, beginning with the most recent command. Repeat the key sequence to recall successively older commands. Down Arrow Trango Systems, Inc. ApexPlus User Manual Rev 3.0 109 Return to more recent commands in the history buffer after recalling commands with the Up Arrow or Ctrl‐P. Repeat the key sequence to recall successively more recent commands. Different Node Levels View Node This is the default node the users log in. This is strictly for viewing configuration
and statistics only. No configuration changes can be made at this level.
View Node Command List
acm
Display ACM feature status
atpc
Display ATPC status
ber
Display ber test parameters
config
Enable Trango configuration mode
cos
Display current status for class of service
datapattern
Display data source for data pattern
date
Display Time of Day
default_opmode
Display default opmode status
failover
Display failover mode
freq
Display Rf Tx/Rx frequency
guard_time
Display failover guard time
help
Display help command
httpd
Display Web server (httpd) status
Ibm
Display In Band Management configuration
ipconfig
Display radio management port configuration
license
Display license enable status
link_history
Display Link history
linktest
Display link test values (RSSI, MSE, BER)
loglevel
Display current syslog logging level
loopback
Display loopback Mode
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 110 model
Display OMU/ODU Model and serial number
mse
Display the MSE (Mean Square Errors) value
odupower
Display ODU -48VDC Supply Power status
opmode
Display Operation Mode status
power
Display Tx power in dBm
remark
Display Location remarks
rps
Display current status of rapid port shutdown
rssi
Display RSSI value
show
Show running system information
siglevel
Display the signal levels for debugging
snmpd
Display SNMP Agent Daemon (snmpd) status
speed
Display current modulation and symbol rate(speed)
status
Display status for different device and ports
sync_status
Display 1+1 synchronization status
sysinfo
Display all system settings
syslog
Display system event log
targetrssi
Display target rssi value
telnetd
Display telnetd server (telnetd) status
temp
Display OMU and ODU temperature
tftpd
Display tftp server (tftpd) status
trap
Display SNMP Trap IP configuration
uptime
Display system uptime
utype
Display the unit type (1+1 configurations)
version
Display IDU/ODU Software version
voltage
Read onboard voltage values from PIC
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 111 Config Node Users can enter this node by typing in the command “config” from the view node. They will be prompted for a password and after successful authentication users enters the config mode. All configuration settings can be changed here. •
All the commands entered without any parameters returns the current configured values and are similar to “view” node. •
All configuration changes are applied immediately and don’t require any reboot (except “speed” in which the settings are applied immediately, but it does require reboot after save). •
All configuration changes have to be saved in order to be persistent across reboot. A single “save” command will save all configuration changes •
Users can go back to the “view” node by typing in the command exit Config Node Command List
CLI
Input Value Range
Default Value
enable <on|off>,
Off
mod <modulation> mse_im <value>
See Table
mod <modulation> mse_de <value>
See Table
enable <on|off>
Off
max_power <0-30>
17
step_size <1-5>
1
ber
N/A
N/A
bootimage
<upgrade | toggle> <omu|odu>>
N/A
config
<export | remove | view | save>
N/A
acm
atpc
cos
Priority 0:
Priority 1:
Priority 2:
Priority 3:
Priority 4:
Priority 5:
Priority 6:
Priority 7:
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 COS Queue = 0
COS Queue = 0
COS Queue = 1
COS Queue = 1
COS Queue = 2
COS Queue = 2
COS Queue = 3
COS Queue = 3
112 custom_profile
<add | remove>
N/A
datapath
<0 | 1 | 2 >
0 (Ethernet Only)
datapattern
<fpga | modem>
fpga
date
<0-99><1-12><1-31><0-23><0-60>
Linux System Date
debug
N/A
N/A
default_opmode
<on/off>
Off
diagnostic
N/A
N/A
egress_margin
< -90 to +90>
N/A
exit
N/A
N/A
failover
<0 | 1 | 2>
0 (Off)
freq
depends on ODU model
0 (this is exception to the valid range)
freq_duplex
depends on ODU model
Dependent on ODU model
ftp
N/A
guard_time
<>
15
help / ?
N/A
N/A
httpd
<on/off>
On
ibm
<on/off> <ip address> <port>
<tagging> <vlanid>
On
ipconfig
<ip address><netmask><gateway>
ip
192.168.100.100
netmask:
255.255.255.0
gateway:
192.168.100.100
Reset will not reset ipconfig, use “reset
ipconfig” to reset the ip address settings.
license_power
license_speed
< license key> for transmit power
extension.
No key installed
< license key> for radio capacity
No key installed
link_history
N/A
N/A
linktest
duration <1-99>
Default 1 (if duration not entered by
user)
loglevel
<0: Setting, 1: Event, 2: Status>
0,1
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 113 loopback
<dig | if | off>
Off
loopback_auto
<5-120>
N/A
model
N/A
No defaults, read directly from the
OMU/ODU
mse
duration <1-99>
Default 1 (if duration not entered by
user)
odupower
<on/off>
Off
opmode
<on/off>
Off
passwd
<passwd> <confirm_passwd> (8char)
trango
<eth > <1-2> <auto_negotiate, duplex,
enable, maxrate, pause, priority,
speed
Both ports configured in the Auto-Neg
Mode. Port 2 only supports 1000BaseT
power
<0-30>
10 dBm
prompt
Character string
N/A
<dscp_weight> <0-7> <1-16>
N/A
qos
<mode> <0 |1>
N/A
qos_info
N/A
N/A
reboot
N/A
N/A
<1-240>
N/A
<cancel>
N/A
port
reload
TrangoLink ApexPLUS
remark
<string 1-100bytes>
Reset will not change the remark settings
reset
N/A
N/A
rps
on/off
off
rssi
Duration <1-99>
Default 1 (if duration not entered by
user)
show
<passwords>
CLI View Node:
trango
CLI Config Node:
trango
SNMP read comm:
public
SNMP write comm:
private
Web Interface:
trango
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 114 snmp trap:
trapstr
siglevel
N/A
N/A
smart_mode
<on | off >
On
snmpd
<on | off >
On
speed
<channel_bw> <modulation>
<0> <qam16>
channel_bw
4/7/10/14/20/28/30/40/50/55/56/80
10
modulation
qpsk, qam16, qam32, qam64, qam128,
qam256
qam128
status
<modem | fifo | pll | port | all |
clear>
N/A
sync
N/A
N/A
sync_status
N/A
N/A
sysinfo
<0-6>
0 (if command executed without any
param)
syslog
<clear>
N/A
targetrssi
<-88 - -25)
-40
tdm
N/A
N/A
telnetd
on/off
off
temp
N/A
N/A
tftpd
on/off
off
value <param> <min | max> <value>
Default action is None. Min/max
parameter values vary by parameter.
threshold
action <param> <action>
param : 0 -rssi, 1 -mse, 2 -ber, 3 -fer,
4 -omu_temp, 5 -odu_temp,6 -in port
util, 7 -out port util 8-link down
min|max: param dependent
action: 0 -none, 1 -snmptrap, 2failover
trap
enable
ip
Trango Systems, Inc. <enable| ip | cr>
Reset will change the prev configured
trapip
<0 – 5>
Off
<1 -5 > <A.B.C.D>
0.0.0.0
ApexPlus User Manual Rev 3.0 115 cr
N/A
N/A
uptime
N/A
N/A
utype
N/A
Main
utype_switch
N/A
N/A
version
N/A
N/A
tftpd
on/off
Off
web_refresh_rate
<0 |2-300>
0 = no refresh
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 116 Debug Node This node is additional management port related settings and users enter the debug node, by typing in the debug command from the config node. Users can re‐enter the view node by entering the cli command from within the debug node. Debug Node Command List cli N/A Used to Enter the CLI (trango‐view) node exit N/A Close the session factory_default N/A Reset all setting to factory default including !P address help N/A display list of commands in the debug node passwd trango Change the password for admin admin level ping <ip address> ping network hosts route N/A display the current system routing table ssh <ip address> ssh into another host syslog N/A print system log uptime N/A display uptime telnet <ip address> telnet into another host tg_reboot N/A Reboot radio Trango Systems, Inc. ApexPlus User Manual Rev 3.0 117 Individual Command Details acm SYNTAX acm acm enable < on| off > acm mod <modulation> mse_im <‐40 ‐ 0> acm mod <modulation> mse_de <‐40 ‐ 0> profile mse_im mse_de enable QPSK ‐20.3 N/A enabled 16QAM ‐25.3 ‐18.5 enabled 32QAM ‐26.3 ‐21.3 enabled 64QAM ‐29.2 ‐24.3 enabled 128QAM ‐32.1 ‐27.2 enabled 256QAM N/A ‐27.2 enabled Configuration Storage: Yes acm without any parameter will display the current status of ACM threshold value and enable options. DESCRIPTION acm is used to display ACM features parameters including ACM enable, and MSE values in the improve/degrade threshold tables. acm enable is used to turn on the adaptive modulation feature. When enabled, the current Rx modulation may shift to different profile based on the current MSE value and a set of pre‐defined MSE degrade and improve thresholds. The speed command must be issued after “acm enable on/off” command. ACM is not symmetric and each end (Tx Rx) may have different profiles at a given time depending upon the MSE values on each end. acm mod is used to update MSE value for degrade or improve threshold table. The new threshold values should be effect immediately upon execution. Certain profiles are not available when initial speed modulation is at QAM256. Below are Trango Systems, Inc. ApexPlus User Manual Rev 3.0 118 the available profiles: profile mse_im mse_de enable QPSK ‐20.3 ‐17.10 enabled 16QAM ‐25.3 ‐18.5 enabled 64QAM ‐29.2 ‐24.3 enabled 256QAM ‐32.1 ‐27.2 enabled Note: Enable/disable certain profile functionality is not supported in this release. Note: RPS should be disabled prior to enabling ACM, then re‐enabled after the link is established with ACM active to prevent inadvertent disconnection of the Ethernet port and loss of management. atpc SYNTAX atpc atpc enable < on| off > atpc max_power <0‐30> atpc step_size <0‐5> Default: enable OFF, max power 17 dBm, step size 1 Configuration Storage: Yes atpc without any parameter will display the current status of ATPC feature DESCRIPTION atpc is used to display ATPC features parameters including ATPC step size, ATPC enable, and ATPC max power. atpc enable: ATPC is used to automatically adjust the remote end ODU transmit power in order to maintain the desired level of RSSI (within 2 dB range of targetrssi) at the local end. This feature will work only when both local and remote radio are enabled. atpc max_power: Set the maximum ATPC power. This parameter is used only when the ATPC is enabled. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 119 User cannot execute the power command when ATPC is turned on. The system will adjust the power automatically based on the “max_power” and “step_size”. atpc step_size: Specified the step size for each of the ATPC command for power up/down By default, for each of the atpc power up/down command from the remote unit, there will be 1 dB increment/decrement. The user may specify this step size to maximum of 5 dB per command. The power command to ODU is 1 dB at a time, but will go up to number of step size per ATPC command. The operator is responsible for meeting legal/regulatory requirements for Tx power. EXAMPLE (CLI‐view) atpc ber SYNTAX ber ber <0‐99 duration in seconds> Default: 1 second Configuration Storage: Yes DESCRIPTION ber without any parameter will display the current BER, LOCK, MSE, RSSI values. This number is calculated by having modem internally generate certain amount of data and monitor the packets to determine the bit error rate. to Note: The BER might not be accurate. It’s based on packet dropped due CRC/FCS errors on Ethernet. BER is not relevant on the ApexPlus due to LDPC error correction, wherein the slope is really steep from no errors to link loss [about < 1dB] bootimage SYNTAX bootimage toggle bootimage upgrade <omu | odu> Trango Systems, Inc. ApexPlus User Manual Rev 3.0 120 Default: N/A Configuration Storage: NO bootimage is a system‐level command. DESCRIPTION bootimage toggle: To switch current images back to the previous updated image in a set of FPGA OS, FW. PIC and ODU firmware are not allowed to be toggled back unless performing bootimage upgrade again. bootimage upgrade: upgrade the required software images on the radio, after the image has been transferred to the radio via tftp or ftp. config SYNTAX config export config remove config save config view Default: N/A Configuration Storage: No config is a system‐level command. DESCRIPTION config export:: The option allows the user to create a ASCII file (config.txt) of the current system configuration, which can then be tftp from the PC, which the user can edit/print or import to other system config remove: This option allows removing the current system configuration file config.bin and all settings will be reset to factory defaults. This is different than the “reset config” where all the password settings are also being reset. config save: Save command is used to save the current system configuration to the flash, so that system settings are persistent across reboot/power cycles. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 121 The config save command should be used after system setting change. Otherwise it will be lost after reboot. Multiple changes can be saved by one save command. config view: The option displays the current system configuration in ASCII format on the console. The saved config is displayed. cos SYNTAX cos cos <priority> <queue> Default: Priority 0 COS Queue = 0 Priority 1 COS Queue = 0 Priority 2 COS Queue = 1 Priority 3 COS Queue = 1 Priority 4 COS Queue = 2 Priority 5 COS Queue = 2 Priority 6 COS Queue = 3 Priority 7 COS Queue = 3 Configuration Storage: YES cos is a system‐level command. DESCRIPTION This command is used to map the priority of the incoming packet to one of the 4 COS queues based on the packet priority per 802.1p. The traffic class of the incoming packet is mapped 1to1 to the 8 priorities. The scheduling is strict priority with COSQ3 > COSQ2 > COSQ1 > COSQ0 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 122 EXAMPLE: (CLI‐config)# cos 2 3 COS map priority=2, queue=3 SUCCESS (CLI‐config)# cos COS scheduling: strict Priority 0: COS Queue = 0 Priority 1: COS Queue = 0 Priority 2: COS Queue = 3 Priority 3: COS Queue = 1 Priority 4: COS Queue = 2 Priority 5: COS Queue = 2 Priority 6: COS Queue = 3 datapath (future) SYNTAX datapath <0‐4> 0:ETH only 1:ETH+T1 2:ETH+E1 DEFAULT VALUE 0: Eth Only DESCRIPTION Select the profile to be used on the datapath of the radio. Bandwidth for TDM is always reserved once selected, regardless of whether data is being sent or not. RELATED speed, license Trango Systems, Inc. ApexPlus User Manual Rev 3.0 123 datapattern SYNTAX datapattern <external | internal> Default: external datapattern Configuration Storage: Yes datapattern without any parameter will display the current status DESCRIPTION Sets datasource for the modem. datapattern can be generated from either fpga (external) or the modem (internal), used to generate PRBS data for testing purposes. The datapattern should be set to “fgpa” during normal mode of operation, otherwise no user data from GigE or the T1 ports will be transmitted. date SYNTAX date <year> <month> <day> <hour> <minute> Default: N/A Configuration Storage: No date without any parameter will display the current time of date. date is a system‐level command. DESCRIPTION Allow the user to set and read the current time and date debug SYNTAX debug Default: N/A Trango Systems, Inc. ApexPlus User Manual Rev 3.0 124 Configuration Storage: No debug is a system‐level command. DESCRIPTION Exit current node and enter the debug mode. EXAMPLE To enter debug mode (trango‐config)# debug debug> RELATED cli default_opmode SYNTAX default_opmode default opmode [on | off] Default: default operation mode OFF Configuration Storage: Yes default_opmode without any parameter will display the default operational mode DESCRIPTION Set the default opmode to user specified input. If ON, the system to power on with ready to be operational if OFF, the user has to explicitly turn on opmode. Opmode settings are dependent upon “default_opmode” after power up Trango Systems, Inc. ApexPlus User Manual Rev 3.0 125 diagnostic SYNTAX diagnostic Default: N/A Configuration Storage: No diagnostic is a system‐level command. DESCRIPTION Diagnostic command is to communicate with all system devices and get a current snapshot of the system status. This is mainly used for debugging purposes. egress_margin SYNTAX egress_margin <‐9 0to ‐90> Default: N/A Configuration Storage: Yes egress_margin is a system‐level command. DESCRIPTION egress_margin allows changing the egress rate from the internal switch to the modem to improve the performance of the strict QoS. If the egress margin is set to 0, then the egress rate is matched to the capacity displayed in the speed command. the egress margin will change this value according to the equation egress rate = channel capacity +egress margin channel capacity. The default setting is sufficient in most cases and will give the best overall capacity, but if mostly small packets are used on the network, the margin may need to be reduced for better enforcement. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 126 exit SYNTAX exit Default: N/A Configuration Storage: No exit is a system‐level command. DESCRIPTION Exit command is used to logout from the current node to the lower node. Typing exit from the debug> node will bring user to the login prompt. EXAMPLE To Switch to view node from “trango‐config” node (trango‐config)# exit (trango‐view) To logout from the system debug>exit RELATED cli, config failover SYNTAX failover failover <0:off, 1: On with port OFF, 2: On with port ON> Default: OFF Configuration Storage: Yes Trango Systems, Inc. ApexPlus User Manual Rev 3.0 127 failover without any parameter will display the current status for the failover mode DESCRIPTION Display and configure the failover mode feature. Failover cable is required between two OMU for this feature to work properly. Option OFF: Disable failover mode feature. Option ON with port OFF: Standby unit disable all Ethernet ports. Option ON with port ON: Standby unit will leave the Ethernet port enabled. When enabled, KeepAlive message will be exchanged between the two ApexPlus OMU to determine their utype. EXAMPLE (CLI‐config)# failover Failover mode: off (CLI‐config)# failover on Failover mode: on SUCCESS freq SYNTAX freq [tx_freq in MHz] Default: no default frequency. 0 Configuration Storage: Yes The setting of frequency is 250 kHz resolution. EXAMPLE: freq 17727.5 freq without any parameter will display the current Tx and Rx frequency for the ODU. DESCRIPTION Sets the transmit frequency and therefore the receive frequency. Only certain Tx‐Rx frequency pairs are valid for each model of the radio. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 128 Certain IDU/ODU PLL synthesizers are programmed for each and every individual frequency. freq_duplex SYNTAX freq_duplex [duplex] Default: 0 Configuration Storage: Yes freq_duplex without any parameter will display the current duplex value DESCRIPTION The duplex distance can be set to any valid frequency within the diplexer frequency range for HP and AP1 models. Regulatory and performance specifications may not be met when using non‐standard settings. Only some HP2 and AP2 Models are adjustable for specific duplex distances Sets the duplex value to be used for programming the transmit frequency and therefore the receive frequency. EXAMPLE (CLI‐config)# freq_duplex ODU duplex: 490.00 (MHz) (CLI‐config)# freq_duplex 500 ODU duplex: 500.00 (MHz) SUCCESS ftp SYNTAX ftp ftp <server_ip> <user_name> ftp> get <file_name>: perform ftp get command. Get file from the ftp server ftp> mode: configure ftp operation mode. Passive or active. ftp> put <file_name> <server path>: perform ftp put command. Put file to the ftp server ftp> logout: logout of ftp session. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 129 Default: server_ip=NULL, user_name=NULL, mode=Passive Configuration Storage: No DESCRIPTION To perform ftp operation. Provide the command with the ftp server IP address and the user login. Enter the password when prompted. ftp> get <file_name>: Do NOT supply the path to the file that needs to be put on to the. It will be stored in the default system directory See example below. ftp> put <source file> <destination>: source will be the filename only,. Destination will include both path and file name. Note: file on the ftp server might need to be deleted before it can be downloaded with the same file name. ftp> mode <mode>: Default operation mode is Passive and can be configure as active with the mode option. ftp> logout: logout of the ftp session. Note: Please ensure that the FTP server is reachable by checking with ping command from debug prompt. EXAMPLE (CLI‐eng)# ftp 10.14.0.85 trango Password: ftp>get zImage ####################################################### Get operation successful with passive mode ftp>put linkloss.txt linkloss.txt ####################################################### Trango Systems, Inc. ApexPlus User Manual Rev 3.0 130 Put operation successful with passive mode ftp>logout (CLI‐config)# guard_time SYNTAX guard_time guard_time <10‐60> seconds Default: 15 seconds. Configuration Storage: Yes guard_time without any parameter will display the current guard time value in seconds. DESCRIPTION Guard time is only valid with failover feature enabled. Whenever a failover has occurred, the guard time will be started and within the guard time period, no additional failover is allowed. Guard time is used to enable the HW failover in the following condition: 1. After election period is over. 2. Whenever the link is established locally. EXAMPLE (CLI‐eng)# guard_time Guard time: 15 seconds (CLI‐eng)# guard_time 20 Guard time: 20 seconds Trango Systems, Inc. ApexPlus User Manual Rev 3.0 131 SUCCESS help / ? SYNTAX ? Default: N/A Configuration Storage: No ? is a system‐level command. DESCRIPTION Typing the ? command will display the list of commands in the current node with a one line description of the commands EXAMPLE (trango‐config)#? <Display the List of cmds> RELATED N/A httpd SYNTAX httpd httpd <on | off> Default: httpd ON. Configuration Storage: Yes Trango Systems, Inc. ApexPlus User Manual Rev 3.0 132 httpd without any parameter will display the current status for the web interface daemon httpd is a system‐level command. DESCRIPTION Turn on httpd server for web interface access. The web interface supports both secure (https) and normal (http) access. ibm SYNTAX ibm ibm enable < on | off > ibm ip <ip_addr> <netmask> ibm port <1‐2: ge1‐ge2> ibm tagging <on|off> ibm vlanid <1‐4088> Default: enable=ON, ip=172.16.1.1 or 172.16.1.2, netmask=255.255.255.0, vlanid=4085. Configuration Storage: Yes Ibm without any parameter will display the current IBM features parameters. DESCRIPTION Ibm is used to configure the In Band Management (IBM) channel to manage the system. Both IBM and the Out of Band Management (OBM) can be used together. The management VLAN ID can be configured based on the user requirement from 1‐4088. The IP address for the IBM channel is independent of the OBM port on the IDU. Ibm can be used with tagging off by simply disabling the ibm tagging – This feature applies to AP‐OMU‐2 models only The 2 IP addresses need to be unique. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 133 ipconfig SYNTAX ipconfig ipconfig ip [ip_addr] [netmask] ipconfig gateway [default_gateway_ip] Default: IP=192.168.100.100, NETMASK=255.255.255.0, GATEWAY=192.168.100.100, REMOTE_IP= 0.0.0.0 Configuration Storage: Yes ipconfig without any parameter will display the current IP configuration and remote IP address. ipconfig is a system‐level command. DESCRIPTION This command is used to set IP address, subnet mask and default gateway for the management port of the system. The system MAC address can be displayed via this command. The change takes place effect immediately. Ipconfig ip: Both IP and netmask parameters must be present. Ipconfig gateway: Configure the default gateway IP. Valid for both Inband and Out‐of‐
band port. license SYNTAX license Display license enable status license_speed <1‐2> <speedkey> license_power <power key> Default: N/A Configuration Storage: No Trango Systems, Inc. ApexPlus User Manual Rev 3.0 134 DESCRIPTION License key command is used to set the license required for using higher speed (> 111 Mbps) or higher transmit power on the radio. Speed license 1 enables speed up to 200Mbps and license 2 enables Max speed. The power license allows higher transmit powers for some frequencies and modulations. Please refer to the actual speed/modulation/channel_width combination for valid profiles. The license key is specific to each unit (management port Ethernet MAC address) and is not transferable. Please refer to valid speed profiles. link_history SYNTAX link_history Default: N/A Configuration Storage: No DESCRIPTION This command displays the link history and the link steady flag. Link history: contains the number of link up/down occurred since the system bootup and this number does not get reset until the radio reboots. Link steady: current status of link steady flag. Link steady set to 1 approximately 40 seconds after the link has established. linktest SYNTAX linktest <iterations> Iteration range from 1‐99 seconds Default: default iteration = 1 second Configuration Storage: NO mse without any parameter will display the current mse value for both Modem1 and Modem2 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 135 DESCRIPTION Linktest command is used to test the current link status and can be used to monitor the link, based on the specified duration. CLI prompt will not be accessible while linktest is running The linktest shows the following in the output Lock: Radio Lock Status 1: if all modem locks are locked 0: if any lock indicator shows unlocked RSSI: The current RSSI value MSE: The current MSE value BER : The instantaneous BER value (1sec interval) loglevel SYNTAX loglevel [0‐2] <0: Setting, 1: Event, 2: Status>Default: N/A Configuration Storage: Yes DESCRIPTION loglevel is used to set the appropriate logging for the system. This command is used to set required log levels for system logging. The log level needs to be set for each activity to be monitored. Once the loglevels are set, the logs can be monitored through the “syslog” command loopback SYNTAX Trango Systems, Inc. loopback ApexPlus User Manual Rev 3.0 136 loopback <off| if |dig | rfl_gen | rf_refl| baseband > loopback_auto Default: OFF Configuration Storage: Yes loopback without any parameter will display the current status DESCRIPTION Activates one of the loopback modes for test purposes. Must be turned off by a command. The CLI is still active while the mode is on to allow monitoring of various parameters. During IF and digital loopback, the transmitter signal from the far end will still be present at the input to the IDU and may cause a poor result. Therefore, the odupower OFF on the remote end of may be required to eliminate any signal from the far end which may corrupt the result. loopback_auto will automatically run loopback if and loopback dig on a far end radio, then restore the link. This allows troubleshooting the far end remotely using the ibm interface. All data ports are disabled while the loopback is running to prevent a traffic loop at the far end switch. All loopback modes will stop live traffic from passing across the link model SYNTAX model Default: N/A Configuration Storage: No DESCRIPTION Display current ODU/OMU model and serial ID. The following information are been displayed: ODU model, OMU model, ODU Serial ID, OMU Model, OMU Serial ID. There are Two OMU models AP‐OMU‐1 and AP‐OMU‐2 – Only difference between the two models is that the AP‐OMU‐1 is limited to In –Band Management using a VLAN, and Trango Systems, Inc. ApexPlus User Manual Rev 3.0 137 the AP‐OMU‐2 can be managed with either a VLAN or without a VLAN. The AP‐OMU‐2 replaces the AP‐OMU‐1. EXAMPLE AP1 with HP1 ODU: (CLI‐config)# model OMU Model: AP‐OMU‐1 OMU Serial ID: 1915805 ODU Model: HP1‐18‐1010‐A ODU Serial ID: R13100475 Tx Freq Min: 17685 Tx Freq Max: 17985 Freq duplex: 1010.00 (MHz) AP2 with HP2 ODU: (CLI‐config)# model OMU Model: AP‐OMU‐1 OMU Serial ID: 8900006 ODU Model: HP2‐11‐490‐1A ODU Serial ID: C 2010DEC02314 Tx Freq Min: 10700.00 Tx Freq Max: 10890.00 Freq duplex: 490.00 (MHz) mse SYNTAX Mse mse <duration>: duration range from 1‐99 seconds Default: default duration = 1 second Trango Systems, Inc. ApexPlus User Manual Rev 3.0 138 Configuration Storage: NO mse without any parameter will display the current mse value for the received signal. DESCRIPTION mse command is used to monitor the Mean Square Error (MSE) of the link received signal based on the specified duration. CLI prompt will not be accessible while linktest is running. odupower SYNTAX odupower odupower < on| off > Default: OFF Configuration Storage: Yes odupower without any parameter will display the current status of ODU power . DESCRIPTION The command is used to Turn ON/OFF odupower. The ODU is powered from the IDU over the IF cable with ‐48VDC It is recommended to turn off the ODU power during initial installing of the ODU on the tower and other maintenance The response time for ODU power ON will vary depending upon the ODU model. It is longer for HP ODUs opmode SYNTAX opmode opmode < on| off > Trango Systems, Inc. ApexPlus User Manual Rev 3.0 139 Default: OFF Configuration Storage: NO opmode without any parameter will display the current status of ODU operation mode DESCRIPTION Opmode command is used to enable the transmitter on the ODU. Opmode settings are not persistent across reboot. See default_opmode command. freq and speed settings are required to be set to a valid value before opmode can be turned ON. passwd SYNTAX Passwd <new_password> <confirm_password> Default: N/A. Default config node passwd is trango Configuration Storage: Yes passwd is a system‐level command. <new_password> must be at least 4 characters and no more than 10 characters. Spaces are not allowed. <new_password> and <confirm_password> must be identical for the new password to take effect DESCRIPTION Update the current password for entering “config‐node”. The new pasword takes effect only after a reboot command or re‐enter the “view‐node” from debug prompt with cli
command.
port SYNTAX port eth <1‐2> auto_negotiate <on| off> port eth <1‐2> duplex <half | full> port eth <1‐2> enable <on| off> Trango Systems, Inc. ApexPlus User Manual Rev 3.0 140 port eth <1‐2> maxrate <0‐1000> port eth <1‐2> pause <on| off> port eth <1‐2> priority <0‐7> port eth <1‐2> speed <0‐1000> Default: see Table below Configuration Storage: YES profile Ge1‐copper Ge2‐fiber Enable On On Pause Frame Off Off Auto Nego On On Duplex Full Full Priority 0 0 Speed 1000 1000 Max Rate 1000 1000 Default Port Settings DESCRIPTION This command is used to set Ethernet port settings. Ethernet: auto negotiation, enable/disable, speed, priority, pause frame, duplex and max rate. Speed/Duplex/Auto Negotiate is fixed for ge2 which is GigE Fiber ports and these setting are not configurable power SYNTAX power power < 0‐30 > Default: 10 dBm Configuration Storage: Yes Trango Systems, Inc. ApexPlus User Manual Rev 3.0 141 opmode without any parameter will display the current status of ODU transmit power level DESCRIPTION Power command is used to set the ODU transmit power level. The maximum level is dependent upon the modulation and ODU model. Ensure that the power does not exceed the rating for the modulation being used or signal distortion will occur The user cannot change power when ATPC is ON. prompt SYNTAX promt <prompt_str> Default: CLI Configuration Storage: Yes prompt is a system‐level command. DESCRIPTION Prompt command is used to update the CLI prompt with more descriptive name of the system. Default prompts are <CLI‐view>, <CLI‐config>. The user may update to a string that is more meaningful. qos SYNTAX qos mode <0|1> qos dscp_weight <0‐7(priority)> <1‐16(weight)> qos_info <1| 2> Default: CLI Trango Systems, Inc. ApexPlus User Manual Rev 3.0 142 Configuration Storage: Yes qos is a system‐level command. DESCRIPTION The qos mode command allows selection of strict or weighted quality of service. In strict mode, all packets must be cleared from the highest priority queue before any lower queues are forwarded. In weighted mode, some packets from all queues will be forwarded, but queues with higher weighted priorties will be serviced more often. The qos_dscp_weight command allows assigning weights to priority levels for layer 2 tagged traffic. The web based DSCP mapping will map an individual code point into a priority level, and then to a specific queue. Priority levels are assigned to specific queues by the cos command. reboot SYNTAX reboot Default: N/A Configuration Storage: No reboot is a system‐level command. DESCRIPTION Reboots entire system including datapath. No configuration changes after the system reboot. reload SYNTAX reload <1‐240> reload cancel Default: N/A Trango Systems, Inc. ApexPlus User Manual Rev 3.0 143 Configuration Storage: No reload is a system‐level command. DESCRIPTION Reboots the radio and reloads the saved configuration after a user set timer (from 1 to 240 minutes) expires. This allows the user to make changes to the system without worrying about permanently losing the connection to the far end. If the user loses connection while running tests or making changes, the unit will reboot itself and restore the last known good configuration and the link will be re‐established. reload cancel will cancel the pending reload. remark SYNTAX remark remark [system_remark] Default: Remark=Trango ApexPlus Configuration Storage: Yes DESCRIPTION Remark of the system typically used for identification purposes. Device string is used to display the device name on the top of the row for all the device‐
level parameters. reset SYNTAX reset config reset ipconfig reset license_key Trango Systems, Inc. ApexPlus User Manual Rev 3.0 144 Default: N/A Configuration Storage: No reset is a system‐level command. DESCRIPTION reset config: Restore all factory default configuration setting including resetting password for system login, CLI config node, Web interface login. Excluding license key and IP configuration. A reboot of the system is required for the command to take effect. reset ipconfig: Reset only the IP configuration to default. Reboot required to make the reset IP configuration take effect. reset license_key: Remove up to 5 license keys. rps SYNTAX rps < on | off> Default: OFF Configuration Storage: Yes rps without any parameter will display the current status of Rapid Port Shutdown feature status. DESCRIPTION This command is used to configure Rapid Port Shutdown (RPS) functionality. The RPS setting needs to be the same on both side of the link for proper operation. If the RPS is enabled the data ports (GigE) on both side of the link are immediately shutdown in the event of a link loss in order to provide a fast trigger mechanism to the external routers and switches, which will reroute the traffic. RPS feature also provide automatic port up after the link is restored. To ensure port up/down due to unstable link. The RPS port up will only activate after detecting a good link with duration of minimum of 40 seconds to 1 minute. Note: RPS should be disabled prior to enabling ACM, then re‐enabled after the link is Trango Systems, Inc. ApexPlus User Manual Rev 3.0 145 established with ACM active to prevent inadvertent disconnection of the Ethernet port and loss of management. Note: refer to link_history command to check for link_steady status. RPS will only take effect if the link_steady is 1. RELATED Sysinfo rssi SYNTAX rssi <iteration> Iteration range from 1‐99 seconds Default: default iteration = 1 second Configuration Storage: NO rssi without any parameter will display the current mse value DESCRIPTION rssi command is used to monitor the instantaneous receive signal level (RSL). It can be used to monitor the stability of the RSL when used in an iterative manner. CLI prompt will not be accessible while rssi command is running. RSSI value range is between –90 and ‐20 show SYNTAX show history show loopback_auto show passwords Default: N/Q Configuration Storage: No Trango Systems, Inc. ApexPlus User Manual Rev 3.0 146 DESCRIPTION show history will display the last 20 commands entered to allow the user to see any changes that were made. show loopback_auto will display the result of the loopback auto command last executed. show passwords will display the passwords for view, config and snmp. This command is only available from the config node. siglevel SYNTAX siglevel Default: N/Q Configuration Storage: No Siglevel will display the signal level related parameters and is used as a debugging tool. DESCRIPTION This command is used to assist debugging any signal level related issue. OMU RSSI: OMU rssi at the N‐Connector – Nominal is ‐8 to ‐14 dBm Normalized MSE/Radial MSE: Norm‐MSE = Radial MSE phase noise residue is minimal Norm‐MSE > Radial MSE there is some amplitude noise (AM distortion) Norm‐MSE < Radial MSE phase noise residue exist, that the PLL did not fully correct Uncorrected Block: Errors reported by modem when passing traffics. EXAMPLE Trango Systems, Inc. (trango‐view)# siglevel OMU RSSI: ‐17 Normalized MSE: ‐313 Radial MSE: ‐306 Uncorrect Block: 0 Alarm: 0x0000 RPS Alarm: 0x00 Tx measure: 0x00 ApexPlus User Manual Rev 3.0 147 smart_mode SYNTAX smart_mode Default: On Configuration Storage: Yes smart_mode without any parameter will display the current status of smart_mode DESCRIPTION Smart mode uses VLAN tags internally to map GE1 on Side A to GE1 on Side B , and GE2 on Side A to GE2 on Side B. If Smart mode is disabled, the traffic will appear at all ports on the receiving end. This is useful for media conversion between copper and fiber ports. Care should be taken to avoid creating loops. Smart mode is designed for cases where only one traffic port is used on each end of the link. Smart mode must be enabled or disabled on both ends for proper operation. This configuration require a config save and reboot commands to take effect. EXAMPLE (CLI‐config)# smart_mode Smart mode: on (CLI‐eng)# smart_mode off Smart mode: off SUCCESS snmpd SYNTAX snmpd snmpd <on | off> Default: ON Configuration Storage: No. Always ON at system bootup. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 148 snmpd without any parameter will display the current status for the tftpd daemon DESCRIPTION Turn on/off snmpd agent on the radio. Must be on to perform any SNMP get/set. EXAMPLE To turn snmpd off (trango‐config)# snmpd off snmpd: off SUCCESS RELATED Ipconfig, snmptrap, trapip speed SYNTAX speed <bandwidth> <modulation> <bandwidth>: 4, 5,7,8, 10,12,14,20,25,28,30,40,50,56,80 <modulation>: qpsk, qam16, qam32, qam64, qam128, qam256 Default: bandwidth 20, QAM128 Configuration Storage: Yes speed without any parameter will display the current speed setting DESCRIPTION Load the corresponding the modem binary file and configure Tx and Rx bandpass filters. The speed command will also configure the standby radio based on the failover configuration being on. Binaries selection for the speed command is based on the following configuration settings: acm enable, modulation and bandwidth. A change in any of these settings will require a re‐load of the binary files using the speed command. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 149 status SYNTAX status modem status pll status port status tdm1(future) status clear Default: N/A Configuration Storage: No status is a system‐level command. DESCRIPTION status modem: display modem link status. MSE, RSSI, BER, FER status pll: display ODU / IDU pll lock status. status port: display Ethernet counters for each ports, RF counters and port utilizations. status tdm: display T1/E1 counters and error status. (future) status clear: clear all Ethernet, RF, TDM counters and port utilization. sync SYNTAX sync Default: N/A Configuration Storage: N/A Trango Systems, Inc. ApexPlus User Manual Rev 3.0 150 sync without any parameter will perform synchronization procedure between Active and Standby unit sync command only allowed to be initiated on Active unit. DESCRIPTION sync is used to perform synchronization procedure to sync up configuration parameters between Active and Standby units. There are some parameters which are independent of utype and therefore, will not be synchronized with this command. The following commands are the ones that do NOT get synchronized on the Standby unit: ibm, ipconfig, license key, loopback mode, opmode, tftpd and traps. EXAMPLE (CLI‐config)# sync Sync Status: Synchronized sync_status SYNTAX sync_status Default: N/A Configuration Storage: N/A sync_status without any parameter will display synchronization status DESCRIPTION sync_status is used to display the current synchronization status between Active and Standby units. This command is not meaningful if 1+1 HSB is not being used. The following parameters will not be synchronized. alarm, cableloss, fanctrl, ibm, ipconfig, license key, loopback mode, opmode, tftpd and traps. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 151 EXAMPLE (CLI‐config)# sync_status Sync Status: Synchronized sysinfo SYNTAX sysinfo sysinfo <0‐6> Default: N/A Configuration Storage: No sysinfo without any parameter will display the current OMU and ODU configuration parameters. sysinfo takes a parameter for information category: 0=version info, 1=Management, 2=Radio Config, 3= System Config , 4=Ethernet 5=ACM, 6=threshold settings. sysinfo is a system‐level command. DESCRIPTION View the current configuration status of the local side IDU and ODU. To select a subset of the entire system info, add the argument 0 through 6 after the sysinfo command syslog SYNTAX syslog syslog [0‐2] syslog clear syslog export Default: 0: SET, 1: EVENT Configuration Storage: Yes syslog without any parameter will display all the system log message for up to 3000 lines. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 152 syslog takes a parameter for log level: 0=SET, 1=EVENT, 2=STAT syslog export, export the syslog to a syslog.txt file which can be tftp by customer. syslog is a system‐level command. DESCRIPTION syslog: will display all the system log entries that have been recorded since the boot up. syslog clear: Clear all syslog. Only 3000 log entries will be captured and will wrap around when overflows. targetrssi SYNTAX targetrssi targetrssi < ‐30 ‐ 80 > Default: ‐40 Configuration Storage: YES targetrssi without any parameter will display the targetrssi of the ODU DESCRIPTION Configure the target RSSI level that the ATPC and ODU gain control will try to maintain. The number should be 2‐3 dB below the expected RSSI based on path calculations. tdm SYNTAX tdm Default: N/A Configuration Storage: No DESCRIPTION Trango Systems, Inc. Displays TDM port mode and coding ApexPlus User Manual Rev 3.0 153 For E1: GDB3 For T1: HDB3 telnetd SYNTAX telnetd telnetd <on | off> Default: telnetd OFF. Configuration Storage: Yes telnetd without any parameter will display the current status for the telnetd daemon telnetd is a system‐level command. DESCRIPTION Linux system command to start the telnetd daemon temp SYNTAX temp Default: N/A Configuration Storage: No temp without any parameter will display the current OMU and ODU temperatures. Updated every 15 seconds temp is a system‐level command. Display of this status is through shared memory. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 154 DESCRIPTION View the current temperatures of OMU and ODU. The temperature reported is the temperature inside the unit in degrees Celcius tftpd SYNTAX tftpd tftpd <on | off> Default: tftpd OFF. Configuration Storage: Yes tftpd without any parameter will display the current status for the tftpd daemon tftpd is a system‐level command. DESCRIPTION Turn on the tftp server. Used to transfer diagnostic file, configuration file and software images during upgrades. threshold SYNTAX threshold threshold action <0‐8(threshold)> <0‐3(action)> threshold value <0‐7(threshold)> <min |max> <value> Defaults: see the table below. param Trango Systems, Inc. min max Action RSSI ‐85 ‐20 none MSE ‐45 ‐15 none BER 0.00E+0 1.00E‐4 none ApexPlus User Manual Rev 3.0 155 FER 0.00E+0 1.00E‐4 none OMU temp ‐10 55 none ODU temp ‐40 58 none In port util 0.0 100.0 none Out port util 0.0 100.0 none Link Down N/A N/A none Configuration Storage: Yes threshold without any parameter will display the current status for threshold setting information. threshold value assigns min and max limits for each of the following parameters (except Link Down which has no min or max: Threshold Parameter Mapping 0 RSSI 1 MSE 2 BER 3 FER OMU Temp (deg C) 4 5 ODU Temp (deg C) 6 In Port Utilization (percent of max available) 7 Out Port Utilization (percent of max available) 8 Link Down Threshold action assigns actions to be taken if the actual parameter crosses the min or max limit. Valid actions are: 0
none (no action) 1
snmp trap is generated and sent to all trap IP Addresses that are enabled 2
switchover to the Hot Standby Link is forced. 3
RPS – Rapid Port Sutdown of the datapath physical interfaces (PHY) is made on both ends of the link to allow layer 2 path switching using STP or RSTP protocols running on a connected switch. threshold is a device‐level command. threshold command is used to set rules for monitoring the system. Whenever the threshold exceeds the programmed values the desired action is set. The utilization rate is expressed as percentage of the current max speed based on the modulation.
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 156 trap SYNTAX trap trap enable <trap #> <on | off> trap ip <trap #> <ip_addr> Default: see below trap # IP enable Trap 1 manager 0.0.0.0 OFF Trap 2 manager 0.0.0.0 OFF Trap 3 manager 0.0.0.0 OFF Trap 4 manager 0.0.0.0 OFF Trap 5 manager 0.0.0.0 OFF Configuration Storage: Yes trap without any parameter will display the current status for the snmptrap information trap is a system‐level command. DESCRIPTION trap is used to enable and configure traps and the IP address which they will be sent to uptime SYNTAX uptime DEFAULT VALUE N/A DESCRIPTION Trango Systems, Inc. Uptime is used to display how long the system has been running, since the last ApexPlus User Manual Rev 3.0 157 reboot/power cycle. It shows the current time and uptime. EXAMPLE To display current uptime (trango‐config)# uptime 20:45:58 up 1:49, load average RELATED Date utype SYNTAX utype Default: N/A Configuration Storage: N/A utype without any parameter will display current utype and other related status. DESCRIPTION Utype command will display unit’s current utype, remote unit status, election period status and sync status. Current utype: No utype, Active, or Standby Remote unit status: no detection, detecting an active, or detecting a standby Election Period: yes (during election period), no (not in election period) Sync Status: Current synchronization status. Synchronized or Not synchronized. EXAMPLE (CLI‐config)# utype Current utype: active Trango Systems, Inc. ApexPlus User Manual Rev 3.0 158 Remote unit status: detecting a standby Election Period: no Sync Status: Synchronized utype_switch SYNTAX utype_switch Default: N/A Configuration Storage: N/A utype_switch does not take any input parameter. Will perform utype switch from Active to Standby. This command only allowed on the Active unit. Can NOT be initiated on Standby unit DESCRIPTION utype_switch manually switch the Active to the Standby unit by forcing a coordinated swap of the utypes between the current active and current standby units. This command is mainly used for image upgrades. During the image upgrades, the standby unit can be upgraded first and when done, perform utype_switch to make the current Active unit Standby to continue the upgrade process. EXAMPLE (CLI‐config)# utype Current utype: active Remote unit status: detecting a standby Election Period: no Sync Status: Synchronized Trango Systems, Inc. ApexPlus User Manual Rev 3.0 159 version version SYNTAX DEFAULT VALUE N/A DESCRIPTION Version command is used to display the current /previous software images on the radio. The system is capable of have multiple images. RELATED bootimage voltage SYNTAX voltage Default: N/A Configuration Storage: No voltage without any parameter will display the current status for the OMU power voltage at different source voltage is a system‐level command. DESCRIPTION Query the voltage level at different power source on OMU. The following power source are being look at: V1.25: V2.5: V3.3: V5.0: web_refresh_rate SYNTAX web_refresh_rate web_refresh_rate <2‐300> Default: 0 = no refresh Trango Systems, Inc. ApexPlus User Manual Rev 3.0 160 Configuration Storage: Yes DESCRIPTION web_refresh_rate without any argument will display the current refresh rate of the web interface in seconds. If the argument is 0, web refresh is turned off an the user must manually refresh the web page from the browser program. If the rate is 2 to 300 seconds, then the web pages will automatically update at the interval given. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 161 Appendix B – Product Specifications Dimensions and Weight Parameter Size Specification AP1 Models: 10.5 x 10.5 x 6 in AP2 Models: 10.5 x 10.5 x 5.5 in Weight AP1Models: 15.1 lbs/6.85 kg AP2 Models: 13.2 lbs/6 kg Environmental Parameter Operating Temperature Range Specification ‐40 deg C to +65 deg C ‐ Functional ‐40 deg C to +55 deg C ‐ Spec Compliant Storage Temperature ‐40 deg C to +75 deg C Humidity 100% Condensing Water resistance IP65 per EN 60529 Salt‐Spray Per IEC/EN‐60950‐22 Emissions Parameter Specification ETSI Conducted Emissions EN 55022 (2006) Class “A” FCC Conducted Emissions FCC 15.107 (a) Class “A” ETSI Radiated Emissions EN 55022 (2006) Class “A” FCC Radiated Emissions FCC 15.109 (a) Class “A” Salt‐Spray Per IEC/EN‐60950‐22 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 162 Reliability Parameter MTBF Specification > 18 years Electromagnetic Compliance Parameter EMC test methods Specification EN 301 489‐1 V1.8 (2008‐04) EN 301 489‐4 V1.4.1 (2009‐02) Power Line Harmonics EN 61000‐3‐2:2006 Power Line Fluctuations/Flicker EN 61000‐3‐3:2008 Electrostatic Discharge (ESD) EN 61000‐4‐2:2009 Radiated RF immunity EN 61000 ‐4‐3:2004, Radiated at 3 V/m Electrical Fast transients EN 61000‐4‐4:2004 Power Line Surge Immunity EN 61000‐4‐5:2006 Powerline RF conducted immunity EN 61000‐4‐6:2005 Voltage Dips and Short Interruptions EN 61000‐1‐4‐11:2004 Wireless Compliance Parameter FCC Specification CFR47 Part 101 CFR47 Part 15 Class A unintentional radiator Canada SRSP‐xx Europe (Harmonized) EN 302 217‐2‐1 EN 302 217‐2‐2 Australia RALI FX5 New Zealand PIB22 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 163 Wireless Parameters Parameter Specification Frequency Range 6‐40 GHz Channel Sizes Supported 3.5, 5, 7, 8.33, 10 , 12.5, 13.75, 14, 20, 25, 27.5, 28, 30, 40, 50, 55, 56, 80 MHz Fixed Modulation Set Levels QAM256, QAM128, QAM64, QAM32, QAM16, QPSK Transmitter Power Accuracy +/‐ 2 dB Transmitter Frequency Accuracy +/‐ 7 ppm Transmitter Center Frequency Synthesizer step size 250 kHz Transmitter Output Power (Muted ) < ‐50 dBm Transmitter Output Return Loss > 10 dB Adaptive Modulation Set Levels QAM256, QAM128, QAM64, QAM32, QAM16 Adaptive Modulation Type Error Free, Hitless through each transition Adaptive Modulation Transitions Thresholds User Settable Automatic Transmitter Power Control > 15 dB range, user configurable step size and max power limit Transmitter Power Maximum Transmit Power by Frequency (dBm) Modulation 6, 7, 8 10 11 13,15 18‐26 28‐40 QPSK 30 26.5 28 26 25 23 16QAM 28 22.5 26 22/25* 22/23* 21 32QAM 28 22.5 26 22/25* 22/23* 21 64QAM 25 20.5 22/25* 21/24* 20/22* 17 128QAM 25 20.5 22/25*
21/24*
20/22*
17 256QAM 24 18.5 21/24*
20/23*
19/21*
16 *With high power license key (AP‐KEY‐3) on AP1 models only Trango Systems, Inc. ApexPlus User Manual Rev 3.0 0
164 Radio Sensitivity Channel Width (MHz) Symbol Rate (Msps) QPSK 3.5 3 5 Receive Sensititivty (dBm) 6‐26 GHz ‐96.6 QAM 16
‐90.4 QAM 32
‐86.4 QAM 64
‐84 QAM 128 ‐80.9 QAM 256
‐77.9 4.3 ‐94.4 ‐88.8 ‐84.8 ‐82.1 ‐79.0 ‐76.0 7 5.6 ‐93.3 ‐87.7 ‐83.7 ‐81.3 ‐78.2 ‐75.2 8.33 7.2 ‐92.7 ‐86.5 ‐82.5 ‐80.3 ‐77.5 ‐74.4 10 8.32 ‐92.2 ‐86.0 ‐82.0 ‐79.6 ‐76.5 ‐73.5 12.5 10.8 ‐91.3 ‐85.4 ‐81.1 ‐78.7 ‐75.4 ‐72.4 14 12.2 ‐90.5 ‐84.3 ‐80.3 ‐77.9 ‐74.8 ‐71.8 20 17.42 ‐89.0 ‐82.8 ‐78.8 ‐76.4 ‐73.3 ‐70.3 25 21.8 ‐88.1 ‐82.0 ‐78 ‐75.4 ‐72.3 ‐69.3 28/30 26 ‐87.3 ‐81.1 ‐77.1 ‐74.7 ‐71.6 ‐68.6 40 34.83 ‐86.0 ‐79.8 ‐75.8 ‐73.4 ‐70.3 ‐67.3 50 43 ‐85.1 ‐78.9 ‐74.9 ‐72.5 ‐69.4 ‐66.4 55/56/80 50 ‐84.5 ‐78.3 ‐74.3 ‐71.9 ‐68.8 ‐65.8* *‐63.8 dBm when set to speed 80 qam256
Channel Width (MHz) Symbol Rate (Msps) QPSK QAM 16 QAM 32 QAM 64 QAM 128 QAM 256 3.5 5 7 8.33 3 4.3 5.6 7.2 ‐93.6 ‐91.4 ‐90.9 ‐89.7 ‐87.4 ‐85.8 ‐84.7 ‐83.5 ‐83.4 ‐81.8 ‐80.7 ‐79.5 ‐81.0 ‐79.1 ‐78.3 ‐77.3 ‐77.9 ‐76.0 ‐75.2 ‐74.5 ‐74.9 ‐73.0 ‐72.2 ‐71.4 10 12.5 14 20 25 28/30 40 50 55/56/80 8.32 10.8 12.2 17.42 21.8 26 34.83 43 50 ‐89.2 ‐88.3 ‐87.5 ‐86.0 ‐85.1 ‐84.4 ‐83.0 ‐82.1 ‐81.5 ‐83.0 ‐82.4 ‐81.3 ‐79.8 ‐79.0 ‐78.1 ‐76.8 ‐75.9 ‐75.3 ‐79.0 ‐78.1 ‐77.3 ‐75.8 ‐75 ‐74.1 ‐72.8 ‐71.9 ‐71.3 ‐76.6 ‐75.7 ‐74.9 ‐73.4 ‐72.4 ‐71.7 ‐70.4 ‐69.5 ‐68.9 ‐73.5 ‐72.4 ‐71.8 ‐70.3 ‐69.3 ‐68.6 ‐67.3 ‐66.4 ‐65.8 ‐70.5 ‐69.4 ‐68.8 ‐67.3 ‐66.3 ‐65.6 ‐64.3 ‐63.4 ‐62.8**
Receive Sensititivty (dBm) 28‐40 GHz **‐60.8 dBm when set to speed 80 qam256 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 165 1+1 Hot Standby Link Protection Parameter Specification Failover Time 150 mSec typical Guard Time User configurable 10 to 60 seconds Power Parameter Specification Input Voltage Range (Direct) ‐40 to ‐72 VDC Input Voltage Range (PoE) ‐43 to ‐50 VDC (At PoE‐GigE‐48 Power input) Power Consumption AP1: Typical 75 Watts AP2: Typical 50 Watts User Interfaces Description Specification Ethernet Traffic Ports and/or In Band Management (IBM) ETH1: RJ45 ‐ 10/100/1000BaseT Out of Band Management (OBM) RJ45‐ 10/100BaseT Direct Power 2 Position Latching screw terminal Block Console/Craft Port Circular 8 pin connector (requires CBLDAT‐4) 1+1 Redundancy Cable Circular 8 pin connector (requires CBLDAT‐RIU4) RSSI Alignment BNC‐Female (CBLDAT‐RSSI recommended) Reset IP/Config Momentary Push Button T1/E1 RJ45 – Multiplexed with Management Port On PoE‐GigE‐48 Antenna Slip‐Fit Circular Waveguide – For compatible antennas, combiners and remote mounts consult Trango ETH2: SFP ‐ 1000BaseT for SFP Module: SFP‐GigE‐ C (1000BaseT) SFP‐GigE‐S (1000BaseLX Single Mode Fiber) SFP‐GigE‐M (1000BaseLX Multimode Fiber) Trango Systems, Inc. ApexPlus User Manual Rev 3.0 166 Ethernet Parameters Parameter Specification Packet Size 64‐9600 Bytes , IPV4, IPV6 Max Capacity L1: 414 Mbps L2: 375 Mbps Data Latency < 100 uS for 64 byte packets, Max capacity (per RFC2544 store and forward) QoS 802.1p Port Prioritization Port mapping to isolate ports VLAN Priority for tagged packets: 4 Classes of Service Bandwidth Shaping per port (Ingress Rate limiting) RSTP Rapid Port Shutdown both ends of link within 50 mSec of link drop T1/E1 Parameters Parameter Specification Clock Source External T1 Compliance T/O 1002‐1993 ITU‐T.G824 GR‐499‐CORE E1 Compliance ITU‐T G.703 ITU‐T G.823 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 167 Appendix C – Cable Wiring This appendix shows the wiring of the various interfaces on the ApexPlus unit. Ethernet Cabling The Figures below show the cable pin‐outs for straight‐through and cross‐over Ethernet cables. The images below conform to EIA/TIA industry standard for 568 A and B. For ApexPlus, the cables should all be straight through cables wired to EIA 568A as shown below. All cables carrying ‐48VDC + Ethernet MUST be shielded Twisted Pair (STP) cables. Crossover cables should not be used. If the first and second pins are orange, the cable is 568B. If the first and second pins are green, the cable is 568A (Figure C‐2). If one end of the cable is A and the other end is B it is a cross‐over cable. Figure 40 EIA/TIA 568A Straight through Figure 41 EIA/TIA 568B Cross‐Over Trango Systems, Inc. ApexPlus User Manual Rev 3.0 168 Console Port Cabling The Interface cable to connect the ApexPlus to a standard Serial port DB9 connector is shown below. The cable can be purchased from Trango. Figure 42: ApexPlus Serial Cable Pin‐Out Trango Systems, Inc. ApexPlus User Manual Rev 3.0 169 Appendix D – MIB OID Listing MIB‐II System Object ID
.1.3.6.1.2.1.1.1.0
Type
DisplayString
Access
RO
Range Limit
Default Value
sysDescr
N/A
Spider-1.0
.1.3.6.1.2.1.1.2.0
.1.3.6.1.2.1.1.3.0
.1.3.6.1.2.1.1.4.0
.1.3.6.1.2.1.1.5.0
.1.3.6.1.2.1.1.6.0
sysObjectID
sysUpTime
sysContact
sysName
sysLocation
OID
TimeTicks
DisplayString
DisplayString
DisplayString
RO
RO
RO
RO
RO
N/A
N/A
N/A
N/A
N/A
.1.3.6.1.4.1.5454.1.90
Object ID
.1.3.6.1.4.1.5454.1.90.1.1.1
.1.3.6.1.4.1.5454.1.90.1.1.2
.1.3.6.1.4.1.5454.1.90.1.1.3
.1.3.6.1.4.1.5454.1.90.1.1.4
.1.3.6.1.4.1.5454.1.90.1.1.5
.1.3.6.1.4.1.5454.1.90.1.1.6
.1.3.6.1.4.1.5454.1.90.1.2.1
.1.3.6.1.4.1.5454.1.90.1.2.2
.1.3.6.1.4.1.5454.1.90.1.2.3
.1.3.6.1.4.1.5454.1.90.1.2.4
.1.3.6.1.4.1.5454.1.90.1.2.5
.1.3.6.1.4.1.5454.1.90.1.2.6
.1.3.6.1.4.1.5454.1.90.1.3.1
.1.3.6.1.4.1.5454.1.90.1.3.2
.1.3.6.1.4.1.5454.1.90.1.3.3
.1.3.6.1.4.1.5454.1.90.1.3.4
.1.3.6.1.4.1.5454.1.90.1.4.1
.1.3.6.1.4.1.5454.1.90.1.4.2
Name
sysFPGAVer
sysOSVer
sysFWVer
sysPICVer
sysModemVer
sysODUFWVer
sysFPGAPreVer
sysOSPreVer
sysFWPreVer
sysPICPreVer
sysModemPreVer
sysODUFWPreVer
sysIDUModel
sysIDUSerialID
sysODUModel
sysODUSerialID
sysMACeth1
sysMACeth2
Type
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
DisplayString
Integer
DisplayString
DisplayString
DisplayString
DisplayString
Access
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Range Limit
Default Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
.1.3.6.1.4.1.5454.1.90.1.5.1
sysIpAddress
IpAddr
RW
.1.3.6.1.4.1.5454.1.90.1.5.2
sysSubnetMask
IpAddr
RW
.1.3.6.1.4.1.5454.1.90.1.5.3
sysDefaultGateway
IpAddr
RW
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
string size 16
(A.B.C.D)
string size 16
(A.B.C.D)
string size 16
(A.B.C.D)
.1.3.6.1.4.1.5454.1.90.1.6.1
.1.3.6.1.4.1.5454.1.90.1.7.1
sysRemarkSystem
sysIBMEnable
DisplayString
Integer
RW
RW
.1.3.6.1.4.1.5454.1.90.1.7.2
sysIBMIp
IpAddr
RW
.1.3.6.1.4.1.5454.1.90.1.7.3
.1.3.6.1.4.1.5454.1.90.1.7.4
.1.3.6.1.4.1.5454.1.90.1.7.5
sysIBMNetmask
sysIBMVlanID
sysIBMVlanPort
IpAddr
Integer
Integer
RW
RW
RW
Name
N/A
Tech Support
Administrator
USA
Trango Trango Systems, Inc. ApexPlus User Manual Rev 3.0 string size 1..100
0(Off), 1(On)
string size 16
(A.B.C.D)
string size 16
(A.B.C.D)
0-4090
100
192.168.100.100
255.255.255.0
192.168.100.100
TrangoLink
ApexPlus
0(Off)
172.168.1.1
255.255.0.0
1
ge1
170 Trango, cont’d Object ID
.1.3.6.1.4.1.5454.1.90.1.8.1
.1.3.6.1.4.1.5454.1.90.1.8.2
.1.3.6.1.4.1.5454.1.90.1.8.3
.1.3.6.1.4.1.5454.1.90.1.9.1.1
Type
DisplayString
DisplayString
DisplayString
Integer
Access
RW
RW
RW
RW
.1.3.6.1.4.1.5454.1.90.1.9.1.2 sysSNMPTrap1Ip
.1.3.6.1.4.1.5454.1.90.1.9.2.1 sysSNMPTrap2Enable
IpAddr
Integer
RW
RW
.1.3.6.1.4.1.5454.1.90.1.9.2.2 sysSNMPTrap2Ip
.1.3.6.1.4.1.5454.1.90.1.9.3.1 sysSNMPTrap3Enable
IpAddr
Integer
RW
RW
.1.3.6.1.4.1.5454.1.90.1.9.3.2 sysSNMPTrap3Ip
.1.3.6.1.4.1.5454.1.90.1.9.4.1 sysSNMPTrap4Enable
IpAddr
Integer
RW
RW
.1.3.6.1.4.1.5454.1.90.1.9.4.2 sysSNMPTrap4Ip
.1.3.6.1.4.1.5454.1.90.1.9.5.1 sysSNMPTrap5Enable
IpAddr
Integer
RW
RW
.1.3.6.1.4.1.5454.1.90.1.9.5.2 sysSNMPTrap5Ip
IpAddr
RW
.1.3.6.1.4.1.5454.1.90.1.10.1 sysImageUpgrade
.1.3.6.1.4.1.5454.1.90.1.10.2 sysImageUpgradeStatus
.1.3.6.1.4.1.5454.1.90.1.10.3 sysImageToggle
Integer
Integer
Integer
RW
RO
RW
.1.3.6.1.4.1.5454.1.90.1.11
.1.3.6.1.4.1.5454.1.90.1.12.1
.1.3.6.1.4.1.5454.1.90.1.12.2
.1.3.6.1.4.1.5454.1.90.1.13.1
.1.3.6.1.4.1.5454.1.90.1.13.2
.1.3.6.1.4.1.5454.1.90.1.14
sysConfigOption
sysDiagnostic
sysDiagnosticStatus
sysSyslogExport
sysSyslogLevel
sysReboot
Integer
Integer
Integer
Integer
Integer
Integer
RW
RW
RO
RW
RW
RW
.1.3.6.1.4.1.5454.1.90.1.15
.1.3.6.1.4.1.5454.1.90.1.16
.1.3.6.1.4.1.5454.1.90.1.17.1
.1.3.6.1.4.1.5454.1.90.1.17.2
.1.3.6.1.4.1.5454.1.90.1.17.3
.1.3.6.1.4.1.5454.1.90.1.17.4
.1.3.6.1.4.1.5454.1.90.1.18
.1.3.6.1.4.1.5454.1.90.1.19
sysResetOption
sysOMUTemp
sysHTTPD
sysSNMPD
sysTFTPD
sysTelnetD
sysRPSEnable
sysClearCounter
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
RW
RO
RW
RW
RO
RW
RW
RW
.1.3.6.1.4.1.5454.1.90.1.20.1. sysSpeedLicenseEnable
.1.3.6.1.4.1.5454.1.90.1.20.1.2sysSpeedLicenseKey1
.1.3.6.1.4.1.5454.1.90.1.20.1.3sysSpeedLicenseKey2
Integer
String
String
RO
RW
RW
.1.3.6.1.4.1.5454.1.90.1.21
sysFailoverMode
Integer
RW
.1.3.6.1.4.1.5454.1.90.1.22
.1.3.6.1.4.1.5454.1.90.1.23
.1.3.6.1.4.1.5454.1.90.1.24.1
.1.3.6.1.4.1.5454.1.90.1.24.2
.1.3.6.1.4.1.5454.1.90.1.24.3
.1.3.6.1.4.1.5454.1.90.1.24.4
.1.3.6.1.4.1.5454.1.90.1.25
.1.3.6.1.4.1.5454.1.90.1.26
sysUtype
sysSync
sysStandbyLinkStatus
sysStandbyODUStatus
sysStandbyRSSI
sysStandbyMSE
sysGuardTime
sysSmartMode
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
RO
RW
RO
RO
RO
RO
RW
RW
Trango Systems, Inc. Name
sysSNMPReadCommStr
sysSNMPWriteCommStr
sysSNMPTrapCommStr
sysSNMPTrap1Enable
Range Limit
Default Value
string size 1-32
string size 1-32
string size 1-32
0(Off), 1(On)
string size 16
(A.B.C.D)
0(Off), 1(On)
string size 16
(A.B.C.D)
0(Off), 1(On)
string size 16
(A.B.C.D)
0(Off), 1(On)
string size 16
(A.B.C.D)
0(Off), 1(On)
string size 16
(A.B.C.D)
public
private
trapstr
0(OFF)
1(IDU), 2(ODU)
0(NA), 1(Failed)
1(Toggle)
1(Export), 2(Import),
3(Remove), 4(Save)
1(Export)
0(NA), 1(Failed)
1(Export), 2(Clear)
0 (NA)
0(NA)
0(NA)
1(REBOOT)
0(Factory Default),
1(IP), 2(License)
N/A
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
0(Off), 1(On)
1(Clear)
0(Disable),
1(Enable)
N/A
N/A
0(Off), 1(ON with port
OFF), 2(ON with port
ON)
0(NO Utype), 1
(Active), 2(Standby)
1(sync)
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
N/A
N/A
10-60 seconds
0(Off), 1(On)
ApexPlus User Manual Rev 3.0 0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(OFF)
0.0.0.0
0(NA)
0(NA)
0(NA)
0(NA)
3
0 (NA)
0 (NA)
N/A
0(Off)
1(On)
1(On)
0(Off)
0(Off)
0(NA)
0(Disable)
N/A
N/A
0
1(Active)
N/A
N/A
N/A
N/A
N/A
15 second
1(On)
171 Modem Section Object ID
Nam e
Access
Range Lim it
Default Value
0(Off)
.1.3.6.1.4.1.5454.1.90.2.1
modemLoopbackMode
Integer
RW
0(Off), 1(Digital), 2(IF),
3(Rf_gen), 4(Rf_refl)
.1.3.6.1.4.1.5454.1.90.2.2
modemDataPattern
Integer
RW
0(FPGA), 1(Modem)
0(FPGA)
.1.3.6.1.4.1.5454.1.90.2.3.1
modemACMEnable
Integer
RW
0(Off), 1(On)
0(Off)
.1.3.6.1.4.1.5454.1.90.2.3.2.1
modemACMProfileQPSKEnable
Integer
RO
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.2.3.2.2
modemACMProfile16QEnable
Integer
RO
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.2.3.2.3
modemACMProfile32QEnable
Integer
RO
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.2.3.2.4
modemACMProfile64QEnable
Integer
RO
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.2.3.2.5
modemACMProfile128QEnable
Integer
RO
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.2.3.2.6
modemACMProfile256QEnable
Integer
RO
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.2.3.3.1.1
modemACMQPSKMSEImprove
Opaque(Float)
RW
(-45) ~ 0
-20.3
.1.3.6.1.4.1.5454.1.90.2.3.3.1.2
modemACMQPSKMSEImproveInt
Integer
RW
(-4500) ~ 0
-2030
.1.3.6.1.4.1.5454.1.90.2.3.3.2.1
modemACM16QMSEImprove
Opaque(Float)
RW
(-45) ~ 0
-25.3
.1.3.6.1.4.1.5454.1.90.2.3.3.2.2
modemACM16QMSEImproveInt
Integer
RW
(-4500) ~ 0
-2530
.1.3.6.1.4.1.5454.1.90.2.3.3.3.1
modemACM32QMSEImprove
Opaque(Float)
RW
(-45) ~ 0
-26.3
.1.3.6.1.4.1.5454.1.90.2.3.3.3.2
modemACM32QMSEImproveInt
Integer
RW
(-4500) ~ 0
-2630
.1.3.6.1.4.1.5454.1.90.2.3.3.4.1
modemACM64QMSEImprove
Opaque(Float)
RW
(-45) ~ 0
-29.2
.1.3.6.1.4.1.5454.1.90.2.3.3.4.2
modemACM64QMSEImproveInt
Integer
RW
(-4500) ~ 0
-2920
.1.3.6.1.4.1.5454.1.90.2.3.3.5.1
modemACM128QMSEImprove
Opaque(Float)
RW
(-45) ~ 0
-32.1
.1.3.6.1.4.1.5454.1.90.2.3.3.5.2
modemACM128QMSEImproveInt
Integer
RW
(-4500) ~ 0
-3210
.1.3.6.1.4.1.5454.1.90.2.3.3.6.1
modemACM256QMSEImprove
Opaque(Float)
RW
(-45) ~ 0
-32.1
.1.3.6.1.4.1.5454.1.90.2.3.3.6.2
modemACM256QMSEImproveInt
Integer
RW
(-4500) ~ 0
-3210
.1.3.6.1.4.1.5454.1.90.2.3.4.1
modemACMQPSKMSEDegrade
Opaque(Float)
RW
(-45) ~ 0
-17.1
.1.3.6.1.4.1.5454.1.90.2.3.4.2
modemACM16QMSEDegrade
Opaque(Float)
RW
(-45) ~ 0
-18.5
.1.3.6.1.4.1.5454.1.90.2.3.4.3
modemACM32QMSEDegrade
Opaque(Float)
RW
(-45) ~ 0
-21.3
.1.3.6.1.4.1.5454.1.90.2.3.4.4
modemACM64QMSEDegrade
Opaque(Float)
RW
(-45) ~ 0
-24.3
.1.3.6.1.4.1.5454.1.90.2.3.4.5
modemACM128QMSEDegrade
Opaque(Float)
RW
(-45) ~ 0
-27.2
.1.3.6.1.4.1.5454.1.90.2.3.4.6
modemACM256QMSEDegrade
Opaque(Float)
RW
-27.2
.1.3.6.1.4.1.5454.1.90.2.3.5.1
modemACMTxProfile
Integer
RO
N/A
.1.3.6.1.4.1.5454.1.90.2.3.5.2
modemACMRxProfile
Integer
RO
(-45) ~ 0
0(QPSK),
1(16Q),2(32Q),3(64Q),
4(128Q), 5(256Q) for
non-256Q, 0(QPSK),
1(16Q),2(64Q),
3(256Q) for 256Q
0(QPSK),
1(16Q),2(32Q),3(64Q),
4(128Q), 5(256Q) for
non-256Q, 0(QPSK),
1(16Q),2(64Q),
3(256Q) for 256Q
.1.3.6.1.4.1.5454.1.90.2.4.1
modemBER
Integer
RO
N/A
.1.3.6.1.4.1.5454.1.90.2.4.2
modemMSE
Integer
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.2.4.3
modemFER
Integer
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.2.5.1
modemLockStatus
Integer
RO
0(No Lock), 1(Lock)
N/A
.1.3.6.1.4.1.5454.1.90.2.5.2
modemTimingLock
Integer
RO
0(No Lock), 1(Lock)
N/A
.1.3.6.1.4.1.5454.1.90.2.5.3
modemPreambleLock
Integer
RO
.1.3.6.1.4.1.5454.1.90.2.5.4
modemLDPCLock
Integer
RO
0(No Lock), 1(Lock)
0(No Lock), 1(Lock)
N/A
N/A
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 N/A
N/A
172 RF Section Object ID
Nam e
Range Lim it
Access
Default Value
Opaque(Float)
RW
Integer
RW
Opaque(Float)
RO
Integer
RO
Opaque(Float)
RW
rfFreqDuplexInt
Integer
RW
ODU model dependant
[In MHz]
ODU model dependant
[in KHz]
ODU model dependant
[In MHz]
ODU model dependant
[in KHz]
ODU model dependant
[In MHz]
ODU model dependant
[in KHz]
rfDefaultOpmode
Integer
RW
0(Off), 1(On)
0(Off)
0(Off)
.1.3.6.1.4.1.5454.1.90.3.1.1.1
rfTxFrequency
.1.3.6.1.4.1.5454.1.90.3.1.1.2
rfTxFrequencyInt
.1.3.6.1.4.1.5454.1.90.3.1.2.1
rfRxFrequency
.1.3.6.1.4.1.5454.1.90.3.1.2.2
rfRxFrequencyInt
.1.3.6.1.4.1.5454.1.90.3.1.2.1
rfFreqDuplex
.1.3.6.1.4.1.5454.1.90.3.1.2.2
.1.3.6.1.4.1.5454.1.90.3.2
.1.3.6.1.4.1.5454.1.90.3.3
rfOpmode
.1.3.6.1.4.1.5454.1.90.3.4.1
rfPow er
.1.3.6.1.4.1.5454.1.90.3.4.2
.1.3.6.1.4.1.5454.1.90.3.5.1
0
0
0
0
0
0
Integer
RW
0(Off), 1(On)
Opaque(Float)
RW
0-30
10
rfPow erInt
Integer
RW
0-300
100
rfChannelsWidth
Integer
RW
20
Integer
RW
3-100
0(QPSK),
1(16Q),2(32Q),3(64Q),
4(128Q), 5(256Q)
Opaque(Float)
RO
N/A
.1.3.6.1.4.1.5454.1.90.3.5.2
rfModulation
.1.3.6.1.4.1.5454.1.90.3.5.3.1
rfSymrate
.1.3.6.1.4.1.5454.1.90.3.5.3.2
rfSymrateInt
.1.3.6.1.4.1.5454.1.90.3.5.4.1
rfSpeed
.1.3.6.1.4.1.5454.1.90.3.5.4.2
rfSpeedInt
.1.3.6.1.4.1.5454.1.90.3.6.1
rfATPCEnable
.1.3.6.1.4.1.5454.1.90.3.6.2
rfATPCMaxPow er
.1.3.6.1.4.1.5454.1.90.3.6.3
rfATPCMaxPow er_Int
QAM128
Integer
RO
N/A
24.6
Opaque(Float)
RO
N/A
110
Integer
RO
N/A
Integer
RW
0(Off), 1(On)
Opaque(Float)
RW
17
0(Off)
17
Integer
RW
1700
1700
.1.3.6.1.4.1.5454.1.90.3.6.4
rfATPCStepSize
Integer
RW
0-5
1
.1.3.6.1.4.1.5454.1.90.3.7
rfAlignmentMode
Integer
RW
0(Off), 1(On)
0(Off)
.1.3.6.1.4.1.5454.1.90.3.8.1
rfTargetRSSI
Opaque(Float)
RW
-40
0(Off)
.1.3.6.1.4.1.5454.1.90.3.8.2
rfTargetRSSIInt
Integer
RW
(-88) ~ (-25)
(-880) ~ (-250) [10ths
of dB ??]
.1.3.6.1.4.1.5454.1.90.3.9
rfODUPow erEnable
Integer
RW
0(Off), 1(On)
.1.3.6.1.4.1.5454.1.90.3.10
rfODUTemp
Integer
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.11.1
rfRSSI
Float
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.11.2
rfRSSIInt
Integer
RO
N/A
.1.3.6.1.4.1.5454.1.90.3.12.1
rfODURFpll
Integer
RO
0(No Lock), 1(Lock)
N/A
.1.3.6.1.4.1.5454.1.90.3.12.2
rfODUIFpll
Integer
RO
0(No Lock), 1(Lock)
N/A
.1.3.6.1.4.1.5454.1.90.3.12.3
rfODUTxpll
Integer
RO
0(No Lock), 1(Lock)
N/A
.1.3.6.1.4.1.5454.1.90.3.12.4
rfODURxpll
Integer
RO
0(No Lock), 1(Lock)
N/A
.1.3.6.1.4.1.5454.1.90.3.12.5
rfIDUTxpll
Integer
RO
0(No Lock), 1(Lock)
N/A
.1.3.6.1.4.1.5454.1.90.3.13.1
rfInDataOctets
Counter32
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.13.2
rfInDataPackets
Counter32
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.13.3
rfInDropPackets
Counter32
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.13.4
rfInPortRate
Counter32
RO
N/A
-40
.1.3.6.1.4.1.5454.1.90.3.13.5
rfInPortUtil
Counter32
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.14.1
rfOutDataOctets
Counter32
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.14.2
rfOutDataPackets
Counter32
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.3.14.3
rfOutPortRate
Counter32
RO
.1.3.6.1.4.1.5454.1.90.3.14.4
rfOutPortUtil
Counter32
RO
N/A
N/A
N/A
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 173 Ethernet Section Access
Range Lim it
.1.3.6.1.4.1.5454.1.90.4.1.1.1
gigeEth1AutoNegotiate
Integer
RW
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.4.1.1.2
gigeEth1Duplex
Integer
RW
0(Half), 1(Full)
1(Full)
.1.3.6.1.4.1.5454.1.90.4.1.1.3
gigeEth1Enable
Integer
RW
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.4.1.1.4
gigeEth1MaxRate
Integer
RW
0-1000
1000
.1.3.6.1.4.1.5454.1.90.4.1.1.5
gigeEth1PauseFrame
Integer
RW
0(Off), 1(On)
0(Off)
.1.3.6.1.4.1.5454.1.90.4.1.1.6
gigeEth1Priority
Integer
RW
0-7
0
.1.3.6.1.4.1.5454.1.90.4.1.1.7
gigeEth1Speed
Integer
RW
0, 100, 1000
1000
.1.3.6.1.4.1.5454.1.90.4.1.1.8
gigeEth1Status
N/A
.1.3.6.1.4.1.5454.1.90.4.1.2.1
gigeEth1InOctets
.1.3.6.1.4.1.5454.1.90.4.1.2.2
gigeEth1InUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.3
gigeEth1InNUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.4
gigeEth1InTotalPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.5
gigeEth1OutOctets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.6
gigeEth1OutUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.7
gigeEth1OutNUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.8
gigeEth1OutTotalPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.9
gigeEth1CRCErrors
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.1.2.10
gigeEth1CollisionErrors
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.1.1
gigeEth2AutoNegotiate
Integer
RW
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.4.2.1.2
gigeEth2Duplex
Integer
RW
0(Half), 1(Full)
1(Full)
.1.3.6.1.4.1.5454.1.90.4.2.1.3
gigeEth2Enable
Integer
RW
0(Off), 1(On)
1(On)
.1.3.6.1.4.1.5454.1.90.4.2.1.4
gigeEth2MaxRate
Integer
RW
0-1000
1000
.1.3.6.1.4.1.5454.1.90.4.2.1.5
gigeEth2PauseFrame
Integer
RW
0(Off), 1(On)
0(Off)
.1.3.6.1.4.1.5454.1.90.4.2.1.6
gigeEth2Priority
Integer
RW
0-7
0
.1.3.6.1.4.1.5454.1.90.4.2.1.7
gigeEth2Speed
Integer
RW
0, 100, 1000
1000
.1.3.6.1.4.1.5454.1.90.4.2.1.8
gigeEth2Status
N/A
.1.3.6.1.4.1.5454.1.90.4.2.2.1
gigeEth2InOctets
.1.3.6.1.4.1.5454.1.90.4.2.2.2
gigeEth2InUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.3
gigeEth2InNUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.4
gigeEth2InTotalPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.5
gigeEth2OutOctets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.6
gigeEth2OutUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.7
gigeEth2OutNUcastPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.8
gigeEth2OutTotalPackets
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.9
gigeEth2CRCErrors
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.2.2.10
gigeEth2CollisionErrors
Counter32
RO
0-4294967296
.1.3.6.1.4.1.5454.1.90.4.3.1
gigeEthPriority0COSQueue
Integer
RW
0-3
0
.1.3.6.1.4.1.5454.1.90.4.3.2
gigeEthPriority1COSQueue
Integer
RW
0-3
0
.1.3.6.1.4.1.5454.1.90.4.3.3
gigeEthPriority2COSQueue
Integer
RW
0-3
1
.1.3.6.1.4.1.5454.1.90.4.3.4
gigeEthPriority3COSQueue
Integer
RW
0-3
1
.1.3.6.1.4.1.5454.1.90.4.3.5
gigeEthPriority4COSQueue
Integer
RW
0-3
2
.1.3.6.1.4.1.5454.1.90.4.3.6
gigeEthPriority5COSQueue
Integer
RW
0-3
2
.1.3.6.1.4.1.5454.1.90.4.3.7
gigeEthPriority6COSQueue
Integer
RW
.1.3.6.1.4.1.5454.1.90.4.3.8
gigeEthPriority7COSQueue
Integer
RW
0-3
0-3
3
3
Object ID
Nam e
Integer
RO
0(Off), 1(On)
Counter32
RO
0-4294967296
Integer
RO
0(Off), 1(On)
Counter32
RO
0-4294967296
Default Value
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 174 Traps Access
Range Lim it
Default Value
.1.3.6.1.4.1.5454.1.90.5.1
trapStartUp
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.2.1
trapReboot
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.2.2
trapIPReset
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.2.3
trapConfigReset
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.3.1
trapRPSPortUp
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.3.2
trapRPSPortDow n
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.4.1
trapEth1StatusUpdate
RO
0(OFF), 1(ON)
N/A
.1.3.6.1.4.1.5454.1.90.5.4.2
trapEth2StatusUpdate
RO
N/A
.1.3.6.1.4.1.5454.1.90.5.5.1
trapLinkLock
RO
.1.3.6.1.4.1.5454.1.90.5.5.2
trapACMTxProfileChange
RO
N/A
Object ID
Nam e
.1.3.6.1.4.1.5454.1.90.5.5.3
trapACMRxProfileChange
RO
0(OFF), 1(ON)
0(NORMAL),
1(LOCKED)
0(QPSK),
1(16Q),2(32Q),3(64Q),
4(128Q), 5(256Q) for
non-256Q, 0(QPSK),
1(16Q),2(64Q),
3(256Q) for 256Q
0(QPSK),
1(16Q),2(32Q),3(64Q),
4(128Q), 5(256Q) for
non-256Q, 0(QPSK),
1(16Q),2(64Q),
3(256Q) for 256Q
.1.3.6.1.4.1.5454.1.90.5.6.1
trapIDUTempMinThreshold
RO
Current IDU Temp
N/A
.1.3.6.1.4.1.5454.1.90.5.6.2
trapIDUTempMaxThreshold
RO
Current IDU Temp
N/A
.1.3.6.1.4.1.5454.1.90.5.6.3
trapODUTempMinThreshold
RO
Current ODU Temp
N/A
.1.3.6.1.4.1.5454.1.90.5.6.4
trapODUTempMaxThreshold
RO
Current ODU Temp
N/A
.1.3.6.1.4.1.5454.1.90.5.6.5
trapMSEMinThreshold
RO
Current MSE value
N/A
.1.3.6.1.4.1.5454.1.90.5.6.6
trapMSEMaxThreshold
RO
Current MSE value
N/A
.1.3.6.1.4.1.5454.1.90.5.6.7
trapBERMinThreshold
RO
Current BER value
N/A
.1.3.6.1.4.1.5454.1.90.5.6.8
trapBERMaxThreshold
RO
Current BER value
N/A
.1.3.6.1.4.1.5454.1.90.5.6.9
trapFERMinThreshold
RO
Current FER value
N/A
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.6.10
trapFERMaxThreshold
RO
Current FER value
N/A
.1.3.6.1.4.1.5454.1.90.5.6.11
trapRSSIMinThreshold
RO
Current RSSI value
N/A
.1.3.6.1.4.1.5454.1.90.5.6.12
trapRSSIMaxThreshold
RO
N/A
.1.3.6.1.4.1.5454.1.90.5.6.13
trapInPortUtilMinThreshold
RO
.1.3.6.1.4.1.5454.1.90.5.6.14
trapInPortUtilMaxThreshold
RO
.1.3.6.1.4.1.5454.1.90.5.6.15
trapOutPortUtilMinThreshold
RO
.1.3.6.1.4.1.5454.1.90.5.6.16
trapOutPortUtilMaxThreshold
RO
Current RSSI value
Current In port
untilization
Current In port
untilization
Current Out port
untilization
Current Out port
untilization
.1.3.6.1.4.1.5454.1.90.5.7.1
trapManualSw itchover
RO
1(Active), 2(Standby)
N/A
.1.3.6.1.4.1.5454.1.90.5.7.2
trapHWSw itchover
RO
1(Active), 2(Standby)
N/A
.1.3.6.1.4.1.5454.1.90.5.8.1
trapRedundancyCableRemoved
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.8.2
trapRedundancyCableReconnected
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.9.1
trapUtypeActiveElected
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.9.2
trapUtypeStandbyElected
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.9.3
trapActiveDetected
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.9.4
trapStandbyDetected
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.9.5
trapActiveDow n
RO
N/A
N/A
.1.3.6.1.4.1.5454.1.90.5.9.6
trapStandbyDow n
RO
N/A
.1.3.6.1.4.1.5454.1.90.5.10
trapSynchronization
RO
N/A
0(Not Synchronized),
1(Synchronized)
Trango Systems, Inc. ApexPlus User Manual Rev 3.0 N/A
N/A
N/A
N/A
N/A
175 Appendix E – Part Numbers ApexPlus Sub‐bands/Tuning Ranges Trango Systems, Inc. ApexPlus User Manual Rev 3.0 176 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 177 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 178 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 179 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 180 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 181 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 182 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 183 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 184 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 185 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 186 Trango Systems, Inc. ApexPlus User Manual Rev 3.0 187 Accessories TRANGO PtP MICROWAVE BAND SPECIFIC ACCESSORIES
Model
Antenna
3/3 dB Dir
Mnt Comb
1.9/6 dB Dir
Mnt Comb
Dir Mnt
Ortho
Comb
Rem Mnt 3/3
Remote Mount
dB Comb
Rem Mnt
1.9/6 dB
Comb
ApexPlus- 6 GHZ
AP1-06-0240-xx
AD6GL-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP HP-MNT-06-WR137 SMC-06-3-HP-R
AP1-06-0252-xx
AD6GL-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP HP-MNT-06-WR137 SMC-06-3-HP-R
AP1-06-0340-xx
AD6GU-xx-R2, -R3 SMC-06-3-HP SMC-06-6-HP OMC-06-HP HP-MNT-06-WR137 SMC-06-3-HP-R
AP2-06-0160-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2 HP2-MNT-6-WR137 SMC-06-3-HP-R
AP2-06-0170-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2 HP2-MNT-6-WR137 SMC-06-3-HP-R
AP2-06-0252-xx
AD6GL-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2 HP2-MNT-6-WR137 SMC-06-3-HP-R
AP2-06-0300-xx
AD6GL-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2 HP2-MNT-6-WR137 SMC-06-3-HP-R
AP2-06-0340-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2 HP2-MNT-6-WR137 SMC-06-3-HP-R
AP2-06-0350-xx
AD6GU-xx-R4, -R3 SMC-06-3-HP2 SMC-06-6-HP2 OMC-06-HP2 HP2-MNT-6-WR137 SMC-06-3-HP-R
Note: All -R3 Antennas require a Remote Mount for the ODU and Waveguide
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
SMC-06-6-HP-R
ApexPlus- 7 GHZ
AP1-07-xxxx-xx
AP2-07-xxxx-xx
AD7G-xx-S2
AD7G-xx-S2
SMC-78-3-HP
SMC-78-3-HP
SMC-78-6-HP
SMC-78-6-HP
OMC-07-HP HP-MNT-78-WR112 SMC-78-3-HP-R SMC-78-6-HP-R
OMC-07-HP HP-MNT-78-WR112 SMC-78-3-HP-R SMC-78-6-HP-R
SMC-78-3-HP
SMC-78-3-HP
SMC-78-6-HP
SMC-78-6-HP
OMC-07-HP HP-MNT-78-WR112 SMC-78-3-HP-R SMC-78-6-HP-R
OMC-07-HP HP-MNT-78-WR112 SMC-78-3-HP-R SMC-78-6-HP-R
ApexPlus- 8 GHZ
AP1-08-xxxx-xx
AP2-08-xxxx-xx
AD8G-xx-R2
AD8G-xx-R2
ApexPlus- 10 GHZ
AP2-10-xxxx-xx
AD10G-xx-S2
NA
NA
NA
NA
NA
NA
ApexPlus- 11 GHZ
AP1-11-xxxx-xx
AP2-11-xxxx-xx
AD11G-xx-S2, -R2
AD11G-xx-S2, -R2
SMC-11-3-HP
SMC-11-3-HP
SMC-11-6-HP
SMC-11-6-HP
OMC-11-HP HP-MNT-11-WR75 SMC-11-3-HP-R SMC-11-6-HP-R
OMC-11-HP HP-MNT-11-WR75 SMC-11-3-HP-R SMC-11-6-HP-R
SMC-13-3-HP
SMC-13-3-HP
SMC-13-6-HP
SMC-13-6-HP
OMC-13-HP HP-MNT-13-WR75 SMC-13-3-HP-R SMC-13-6-HP-R
OMC-13-HP HP-MNT-13-WR75 SMC-13-3-HP-R SMC-13-6-HP-R
SMC-15-3-HP
SMC-15-3-HP
SMC-15-6-HP
SMC-15-6-HP
OMC-15-HP HP-MNT-15-WR62 SMC-15-3-HP-R SMC-15-6-HP-R
OMC-15-HP HP-MNT-15-WR62 SMC-15-3-HP-R SMC-15-6-HP-R
SMC-18-3-HP
SMC-18-3-HP
SMC-18-6-HP
SMC-18-6-HP
OMC-18-HP HP-MNT-18-WR42 SMC-18-3-HP-R SMC-18-6-HP-R
OMC-18-HP HP-MNT-18-WR42 SMC-18-3-HP-R SMC-18-6-HP-R
SMC-23-3-HP
SMC-23-3-HP
SMC-23-6-HP
SMC-23-6-HP
OMC-23-HP HP-MNT-23-WR42 SMC-23-6-HP-R SMC-26-3-HP-R
OMC-23-HP HP-MNT-23-WR42 SMC-23-6-HP-R SMC-26-3-HP-R
SMC-26-3-HP
SMC-26-3-HP
SMC-26-6-HP
SMC-26-6-HP
NA
NA
HP-MNT-26-WR42 SMC-26-3-HP-R SMC-26-6-HP-R
HP-MNT-26-WR42 SMC-26-3-HP-R SMC-26-6-HP-R
SMC-28-3-HP
SMC-28-6-HP
NA
HP-MNT-28-WR28 SMC-28-3-HP-R SMC-28-6-HP-R
SMC-32-3-HP
SMC-32-6-HP
NA
HP-MNT-32-WR28 SMC-32-3-HP-R SMC-32-6-HP-R
SMC-38-3-HP
SMC-38-3-HP
SMC-38-3-HP
SMC-38-6-HP
SMC-38-6-HP
SMC-38-6-HP
ApexPlus- 13 GHZ
AP1-13-xxxx-xx
AP2-13-xxxx-xx
AD13G-xx-S2, -R2
AD13G-xx-S2, -R2
ApexPlus- 15GHZ
AP1-15-xxxx-xx
AP2-15-xxxx-xx
AD15G-xx-S2
AD15G-xx-S2
ApexPlus- 18 GHZ
AP1-18-xxxx-xx
AP2-18-xxxx-xx
AD18G-xx-S2, R2
AD18G-xx-S2, R2
ApexPlus- 23 GHZ
AP1-23-xxxx-xx
AP2-23-xxxx-xx
AD23G-xx-S2, -R2
AD23G-xx-S2, -R2
ApexPlus- 26 GHZ
AP1-26-xxxx-xx
AP2-26-xxxx-xx
AD26G-xx-S2
AD26G-xx-S2
ApexPlus- 26 GHZ
AP1-28-xxxx-xx
AD28G-xx-R2
ApexPlus- 32 GHZ
AP1-32-xxxx-xx
AD32G-xx-R2
ApexPlus- 38 GHZ
AP1-38-xxxx-xx
AP1-38-xxxx-xx
AP2-38-xxxx-xx
AD38G-xx-R2
AD38G-xx-R2
AD38G-xx-R2
Trango Systems, Inc. OMC-38-HP HP-MNT-38-WR28 SMC-38-3-HP-R SMC-38-6-HP-R
OMC-38-HP HP-MNT-38-WR28 SMC-38-3-HP-R SMC-38-6-HP-R
OMC-38-HP HP-MNT-38-WR28 SMC-38-3-HP-R SMC-38-6-HP-R
ApexPlus User Manual Rev 3.0 188 Appendix F – Link Install and Commissioning Logs Standardized forms are provided here for use during the installation and configuration phase and to serve as a record of the link performance at the time of installation. Trango Systems, Inc. ApexPlus User Manual Rev 3.0 189 Site Information Customer: Site Name: Site Address: Site Coordinate: Radio Model: Radio Serial # Site Access notes: Antenna Information Antenna model Antenna size Height above Ground Level Does it meet Fresnel zone requirement? Yes No Antenna Mount is properly secure? Yes No Is the Antenna properly secure? Yes No Is the Mount Properly grounded? Yes No Is the Antenna Properly grounded? Yes No Is the Antenna side strut installed? Yes No Is the Antenna weather proof? Yes No Was the O‐Ring installed properly? Yes No Trango Systems, Inc. ApexPlus User Manual Rev 3.0 190 Outdoor Unit Information Model of ODU : Direct or Remote ODU Mount Direct Remote Are all four latches properly closed? Yes No What is the ODU polarization? H V Does the ODU look damaged? Yes No Is the Gore Vent damaged? Yes No PoE Information (Optional) Is PoE Properly grounded to Earth Ground Yes No Cat 5e or Cat 6 Shielded Twisted Pair used on PoE‐
GigE‐48 to ODU connections (Data and Management Ports) Yes No Are the Strain Reliefs for the cables tight Yes No Are all cables properly labeled and secure? Yes No Was a pull test conducted on the terminal block to ensure that the wires are secure? Yes No Power Supply Information Type of power Supply: Redundant power to the ODU or PoE? Yes No Measure input voltage at PoE (‐VDC) Properly grounded to the Earth? Yes No Are the leads properly terminated to the power supply’s terminal block Yes No Trango Systems, Inc. ApexPlus User Manual Rev 3.0 191 Ethernet/Fiber Cable Information Cable type: Cable Length: Secure connection to the PoE with no tabs missing? Secure connection to the ODU with no tabs missing? Proper weather proofing at all necessary Points? Yes No Point of entry properly weather proof? Yes No Point of entry properly grounded? Yes No Is there a drip loop at the ODU? Yes No Is cable properly secure? Yes No Is there any damage to the cable, bends, kinks, etc.? Yes No Remarks: Remarks: Trango Systems, Inc. ApexPlus User Manual Rev 3.0 192 Notes: Installation Performed by: Name: Date: Title: Contact Number: Company: Signature: Installation Approved by: Name: Date: Title: Contact Number: Company: Signature: Trango Systems, Inc. ApexPlus User Manual Rev 3.0 193 Link Configuration Log Site A Information Customer: Site Name: Site Address: Site Coordinate: Site Configuration: 1+0/ 1+1 / 2+0 (Circle One) Site Access notes: Complete after Link Configuration completed Site A Configuration Performed by: Name: Date: Title: Contact Number: Company: Signature: Site A Configuration Approved by: Name: Date: Title: Contact Number: Company: Signature: Trango Systems, Inc. ApexPlus User Manual Rev 3.0 194 Site A Outdoor Unit #1 Information Model of ODU ODU Serial Number OMU Serial Number OMU MAC Address OMU IP Address OBM: IBM: Polarization of this unit V or H Antenna Model Antenna Serial Number Transmit Frequency Setting MHz Transmit Power Setting dBm Speed/Modulation Setting Adaptive Coding & Modulation ON / OFF Automatic Transmit Power Control ON / OFF Target RSSI Setting dBm Recorded RSSI dBm Expected RSSI from PCN dBm Recorded MSE dB Linktest 99: stable RSSI, MSE, Lock? Yes / No 24 Hour Traffic Test No Errors –Pass / Errors: Fail Utype Active/Standby Trango Systems, Inc. ApexPlus User Manual Rev 3.0 195 Site A Outdoor Unit #2 Information Model of ODU ODU Serial Number OMU Serial Number OMU MAC Address OMU IP Address OBM: IBM: Polarization of this unit V or H Combiner Model Combiner Serial Number Transmit Frequency Setting MHz Transmit Power Setting dBm Speed/Modulation Setting Adaptive Coding & Modulation ON / OFF Automatic Transmit Power Control ON / OFF Target RSSI Setting dBm Recorded RSSI dBm Expected RSSI from PCN dBm Recorded MSE dB Linktest 99: stable RSSI, MSE, Lock? Yes / No 24 Hour Traffic Test No Errors –Pass / Errors: Fail Utype Active/Standby Trango Systems, Inc. ApexPlus User Manual Rev 3.0 196 Site B Information Customer: Site Name: Site Address: Site Coordinate: Site Configuration: 1+0/ 1+1 / 2+0 (Circle One) Site Access notes: Complete after Link Configuration completed Site B Configuration Performed by: Name: Date: Title: Contact Number: Company: Signature: Site B Configuration Approved by: Name: Date: Title: Contact Number: Company: Signature: Trango Systems, Inc. ApexPlus User Manual Rev 3.0 197 Site B Outdoor Unit #1 Information Model of ODU ODU Serial Number OMU Serial Number OMU MAC Address OMU IP Address OBM: IBM: Polarization of this unit V or H Antenna Model Antenna Serial Number Transmit Frequency Setting MHz Transmit Power Setting dBm Speed/Modulation Setting Adaptive Coding & Modulation ON / OFF Automatic Transmit Power Control ON / OFF Target RSSI Setting dBm Recorded RSSI dBm Expected RSSI from PCN dBm Recorded MSE dB Linktest 99: stable RSSI, MSE, Lock? Yes / No 24 Hour Traffic Test No Errors –Pass / Errors: Fail Utype Active/Standby Trango Systems, Inc. ApexPlus User Manual Rev 3.0 198 Site B Outdoor Unit #2 Information Model of ODU ODU Serial Number OMU Serial Number OMU MAC Address OMU IP Address OBM: IBM: Polarization of this unit V or H Combiner Model Combiner Serial Number Transmit Frequency Setting MHz Transmit Power Setting dBm Speed/Modulation Setting Adaptive Coding & Modulation ON / OFF Automatic Transmit Power Control ON / OFF Target RSSI Setting dBm Recorded RSSI dBm Expected RSSI from PCN dBm Recorded MSE dB Linktest 99: stable RSSI, MSE, Lock? Yes / No 24 Hour Traffic Test No Errors –Pass / Errors: Fail Utype Trango Systems, Inc. Active/Standby ApexPlus User Manual Rev 3.0 199 Appendix G – Declaration of Conformity We, Trango Systems, Inc., 14118 Stowe Drive Ste B Poway, California, 92127 USA Tel +1 858 391‐0010 Fax +1 858 391‐0020 Hereby declare that the product(s) listed below, Product Name: TrangoLINK ApexPLUS All Outdoor Unit, 100Mbps Model No: AP1‐XX‐YYYY‐ZZ, AP2‐XX‐YYYY‐ZZ Where: XX = the Frequency Band in GHz YYYY= the T/R Spacing ZZ= the Sub‐band to which this declaration relates, are in conformity with the following standards and/or other normative documents: EN 302 217‐2‐2 (2007‐04) EN 302 217‐2‐1 (2005‐08) EN 301 489‐17 v1.2.1 (2002‐08) EN 60950‐1/IEC 60950‐1:2001 First Edition EN 50385: 2002 We hereby declare that all essential radio test suites have been carried out and that the above named products are in conformity with all the essential requirements of Directive 1999/5/EC. The conformity assessment procedure referred to in Article 10(5) and detailed in Annex IV of Directive 1999/5/EC has been followed with the involvement of the following Notified Body using the CB Scheme: Trango Systems, Inc. ApexPlus User Manual Rev 3.0 200 Glossary AGC ATPC BER BPF Cat5e COS dB dBm E1 FCC FEC FPGA FTP GigE HTTP HTTPD HTTPS IF LB LDPC LED LIU MSE ODU OMU Opmode OS PIC PoE QAM QoS QPSK RF RJ‐45 RS‐232 RSSI Rx SFP SNMP SSH Sysinfo Automatic Gain Control Automatic Transmit Power Control Bit Error Rate Band Pass Filter Category 5 enhanced Cable Class Of Service Decibel Decibel relative to one milliwatt European‐Carrier 1 Federal Communication Commission Forward Error Correction Field Programmable Gate‐Array File Transfer Protocol Gigabit Ethernet HyperText Transfer Protocol HyperText Transfer Protocol Daemon HyperText Transfer Protocol Secure Intermediate Frequency Loopback Low Density Parity Check Light‐emitting Diode Line Interface Unit Mean Square Error Outdoor Unit Outdoor Modem Unit Operation Mode Operating System A Series of microcontrollers a product of the Microchip Technology Power Over Ethernet Quadrature Amplitude Modulation Quality of Service Quadrature Phase Shift Keying Radio Frequency Registered Jack ‐ 45 Recommended Standard 232 Receive Signal Strength Indicator Receive Small Form‐factor Pluggable Simple Network Management Protocol Secure Shell System Information Trango Systems, Inc. ApexPlus User Manual Rev 3.0 201 T1 TDM T/I TFTP TFTPD Tx VLAN WISP 1.544 Mbps telephony carrier 1 Time‐Division Multiplexing Threshold to Interference Trivial File Transfer Protocol Trivial File Transfer Protocol Daemon Transmit Virtual Local Area Network Wireless Internet Service Provider Trango Systems, Inc. ApexPlus User Manual Rev 3.0 202