Download CueServer 2 User`s Manual
Transcript
Interactive Technologies, Inc. CueServer 2 User's Manual - 1.0.8 The question mark ? can be used to ask what the current selection is. A selection string will be returned, which will consist of a single number (like 3) or a range (like 5>7+9), or if no outputs are selected, 0 will be returned. Examples Output 1 Selects output 1. Future action commands will be directed towards output 1. Also returns 0, or 1 to indicate if the output is currently off or on. Output 1>5 On Turns on outputs 1 thru 5. Output 1>3+5>8 Off Turns off outputs 1 through 3 and 5 through 8. Output 7 At 50 Sets the level of output 7 to 50% (any non-zero level turns an output on). Output ? Returns the current output selection in the format of a single number like 3, or a range like 5>7+9. See Also • Selection Operators • At, Off, On Last update: 2015/04/28 09:11:45 Page 78 of 169