Download Opman HS26 v214.qxd - Fieldpiece Instruments

Transcript
THE ORIGINAL
STICK METER
MODEL: HS26
VΩ
COM
CAT.III 600V ~ 200μA MAX
DH
PH
Introduction
Maintenance
The HS26 is smaller, simpler and more rugged
than it’s bigger brothers, and still works with all
Fieldpiece accessory heads. All Fieldpiece accessory heads slide on the top, enabling the user to test a
wide variety of parameters. All this plus the removable tip test leads make safe one-handed testing a
snap.
Clean the exterior with clean dry cloth. Do not use
liquid.
Battery replacement: When the multimeter displays "
" the battery must be replaced. Disconnect
and unplug leads, turn meter off, and remove the battery cover. Replace the battery with a NEDA type 1604
9V battery.
For Your Safety
MAX
HOLD
600
200
200
VAC
VDC
2000m
2000m
200m
200m
MFD
200
Ω
200
µADC
200
The Original Stick Meter
HS26
General: Disconnect the test leads before opening
the case. Inspect the test leads for damage to the
insulation or exposed metal. Replace if suspect.
Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets,
fixtures, etc., which might be at ground potential.
Keep your body isolated from ground by using dry
clothing, rubber shoes, rubber mats, or any approved
insulating material. When disconnecting from a circuit, disconnect the "RED" lead first, then the common lead. Work with others. Use one hand for testing. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Keep your
fingers behind the finger guards on the probes. Do
not measure resistance when circuit is powered. Do
not apply more than rated voltage between input and
ground.
Voltage tests: Do not apply more than 600VDC or
600VAC to V ranges.
AC tests: Disconnect the meter from the circuit
before turning any inductor off, including motors,
transformers, and solenoids. High voltage transients
can damage the meter beyond repair. Do not use
during electrical storms.
Symbols Used
! Caution, refer to manual.
Ground
Double insulation
Alternating current
Direct current
!
WARNINGS
!
DISCONNECT AND UNPLUG TEST LEADS
before opening case.
This instrument complies with the requirements of
the following European Community Directives:
89/336/EEC (Electromagnetic Compatibility) and
73/23/EEC (Low Voltage) as amended by 93/68/EEC
(CE Marking).
OPERATOR’S MANUAL
SPECIFICATIONS
Continuity
Safety
Display: 3½ digit liquid crystal display (LCD) with a
maximum reading of 1999.
Overrange: "OL" mark indication.
Auto power off: approx 60 minutes.
Operating environment: 32 to 122°F (0 to 50°C) at
<70% R.H.
Storage temperature: -4 to 140°F (-20 to 60°C), 0
to 80% R.H. with battery removed.
Accuracy: Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative
humidity.
Temperature Coefficient: 0.1×(specified accuracy)
per °F/°C. (32 to 64°F(0 to 18°C), 82 to 122°F(28
to 50°C)).
Power: Single standard 9-volt battery, NEDA 1604,
JIS 006P, IEC 6F22.
Battery life: 150 hours typical with carbon zinc,
300 hours typical with alkaline.
Accessories: 400AAC current clamp, one pair test
leads, one pair alligator clips, carrying case, 9V
battery (installed), and operating instructions.
Audible indication: Less than 100Ω
Visual indication: Green LED will be on continuously.
Response time: 100ms
Overload protection: 500VDC or AC rms
Conforms to UL61010-1, CE (EN61010-1), CATIII
600V, Class II, Pollution Degree 2, Indoor Use Only.
CATIII: Is for measurements performed in the building installation.
EMC: Conforms to EN61326-1.
AC Volts (50Hz - 500Hz)
Capacitance (MFD)
Range: 200μF
Resolution: 0.1μF
Test frequency: 42Hz
Test voltage: <3.0V
Accuracy: ±(3% rdg + 5 dgts)
Overload protection: 500VDC or AC rms
DC Current
Ranges: 200 μA
Resolution: 0.1μA
Accuracy: ±( 1.0% rdg + 2 dgts)
Voltage burden: 1V
Overload protection: 500VDC or AC rms
Ranges: 200mV, 2000mV, 200V, 600V
Resolution: 0.1mV
Accuracy: ±(1.2% rdg + 3 dgts)
±(2.0% rdg + 5 dgts) on 600V range
Input impedance: 1MΩ
Overload protection: 600VDC or AC rms,
600VDC/AC rms 15 sec on 200mV range
Transient protection: 6kV for 10μ sec
DC Volts
Diode Test
Resistance
Test current: ∼1mA
Accuracy: ±(1.5% rdg + 3 dgts)
Open circuit volts: 3.0VDC typical
Overload protection: 500VDC or AC rms
Ranges: 200Ω
Resolution: 0.1Ω
Accuracy: ±(1.0% rdg + 3 dgts)
Open circuit volts: 3.0VDC typical
Overload protection: 500VDC or AC rms
Ranges: 200mV, 2000mV, 200V
Resolution: 0.1mV
Accuracy: ±(0.5% rdg + 1 dgt)
Input impedance: 1MΩ
Overload protection: 600VDC or AC rms,
600VDC/AC rms 15 sec on 200mV range
Transient protection: 6kV for 10μ sec
Limited Warranty
This meter is warranted against defects in material or workmanship for one year from date of purchase. Fieldpiece will replace or repair the defective
unit, at its option, subject to verification of the defect.
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.
Any implied warranties arising from the sale of a
Fieldpiece product, including but not limited to
implied warranties of merchantability and fitness for a
particular purpose, are limited to the above.
Fieldpiece shall not be liable for loss of use of the
instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of
such damage, expenses, or economic loss.
State laws vary. The above limitations or exclusions may not apply to you.
Obtaining Service
Call Fieldpiece Instruments for one-price-fix-all
warranty service pricing. Send check or money order
for the amount quoted. Send the meter freight prepaid to Fieldpiece Instruments. Send proof of date
and location of purchase for in-warranty service. The
meter will be repaired or replaced, at the option of
Fieldpiece, and returned via least cost transportation.
Selecting Ranges
For DC voltage, set the meter to the VDC parameter instead of VAC (shown below).
For all ranges choose a range just above the value
you expect. If display reads “OL” (overload), select a
higher range. If display shows less than three numbers, select a lower range for better resolution.
600
200
200
VAC
VDC
2000m
2000m
200m
Voltage
Works With Fieldpiece Accessory
Heads!
Diode Test
CLAMP
300V
CAT.III
400A
200m
MFD
µADC
Ω
200
200
200
AC Current
Clamp
!
1AAC / 1mVAC
400AAC MAX
600
200
200
VAC
VDC
2000m
ACH4
Resistance
2000m
200m
600
200m
MFD
200
Ω
200
µADC
200
200
200
VAC
VDC
2000m
2000m
VΩ
COM
CAT.III 600V ~ 200μA MAX
Capacitance
200m
MFD
200m
µADC
200
Ω
200
200
MAX
HOLD
600
200
200
VAC
VDC
2000m
600
200
200
VAC
VDC
2000m
MAX
600
Flame rectification
200m
200m
MFD
200
Ω
µADC
200
200
200
200
VAC
VDC
2000m
200m
200
Ω
200
200m
MFD
200
600
MFD
2000m
200m
2000m
200m
HOLD
2000m
µADC
200
200
200
VAC
VDC
2000m
Ω
200
µADC
200
2000m
200m
200m
MFD
The Original Stick Meter
µADC
Ω
200
The Original Stick Meter
HS26
200
200
HS26
(1)
(2)
Connect to Fieldpiece accessory heads by simply
attaching them to the top of meter (1) or attach
remotely through leads (2). For most heads, move
dial to mVDC range shown (1). For the AAC clamp
(ACH4), move dial to VAC range (2).
Hi Voltage Indicator
Modular Expandability
In any VAC/VDC range, when you touch a voltage
greater than 30V, the beeper will beep and the red HiV LED will blink. BE CAREFUL!
Modular expandability is the ability for accessory
heads and meters to change configurations to match
the various needs of an HVAC/R technician.
Capacitance
For motor-start and motor-run capacitors.
Disconnect the capacitor from power first. Short the
terminals to discharge the capacitor. Disconnect any
resistors that might be between the terminals of the
capacitor.
LE
LO
TT
BA
EN
GL
H
IS
SH
ME
TR
En
glish
Ft
/m
M
M in
et
PH
ric
ºF
KM M/s
OFF
/h
r
ºC
IC
SC
R4
04
A
SC p
or m re
SH Tesu
es
Pr
t
Se M
AT
T/C l
Ca
RE
AD
(1 er
6 ag
se e
c)
Re
tim al
e
X2
4
AA
V3
AU
OFFTO
-
T/C
CAL AU
TO
OFF
2
aa
aa
a
aa
aaa
aaaaa
aaaaa
AOX2
°F
°C
ON
Lo Batt
GAS
LC
10 D X
0
BA
TT
is
h Av
ric
OIL
BLE
gl
et
Accessory heads, like the included ACH4, are the
sensors of multiple parameters measured by technicians every day. They plug into a mV range (depending on the head) of a multimeter. The multimeter will
display whatever the head is measuring. Instead of
having to purchase and carry a separate instrument
for each parameter, a technician can use multiple
heads and a single multimeter to do the job.
Here are four of the many heads available:
AAV3
Air Velocity and Temperature
ADMN2 Dual-Port Manometer
AVG2
Digital Vacuum Gauge
AOX2 Combustion Check
e
l Typ
Fue
TEMP
%CO
%O 2
STA
ON
LO
En
M
TO
AUOFF
AS
Comb
Chec ustio
n
k
VΩ
A
& ir
He Te Velo
ad mp cit
era y
tu
re
ON
Press MAX to store highest reading on the display.
Press MAX again to return display to real-time reading. Press HOLD to hold current data on the display.
When testing electrical circuits with two hands,
there is a risk that a careless mistake may complete a circuit
through your body and potentially
cause death or injury.
First disconnect the top half of
red test lead and plug tip directly
into Volts jack. Plug alligator clip
lead into the COM jack (you may
need to use a lead with tip
removed as an extension). Then
clip the alligator lead to one test
point.
With the black alligator lead
secured, you’re now free to hold
the meter with one hand and
touch other test points with the
probe tip.
!
ACH4
AB
ST
Safe One-Handed Testing
400A
AC Current
Clamp
n
a tiot g
er
olin A
rig hea bco
34
R1
R ef per Su
Su d
an
Because the wire insulation is silicone the leads
will stay flexible in cold weather and will not melt if
bumped by a soldering iron.
300V
CAT.III
1AAC / 1mVAC
400AAC MAX
MAX and Data HOLD
Silicone Leads
CLAMP
Accessory Heads
aa
aa
a
aa
aaa
aaaaa
aaaaa
P1
Accessory heads (the sensors) send a mV signal,
which represents the value of the parameter being
tested. Heads can attach directly to the top of a Stick
meter, DL3 data logger, or EHDL1. They can also
plug into any meter with mV ranges using ADLS2
leads.
ON
LCD X
100
LO BATT
READ
Air Velocity
& Temperature Average
English (16 sec)
Head
Metric
English
Metric
Ft/min
MPH
ºF
M/s
KM/hr
ºC
Real
time
P2
Dual-Port
Manometer
Accessory
Head
0.1
ON
Combustion
Check
ON
STABLE
Lo Batt
Lo Batt
ENGLISH
GAS
Fuel Type
Resolution
OIL
0.01
METRIC
(LCD/10)
TEMP
%CO2
%O2
P1-P2
P2
P1
OFF
ZERO
°C °F
AUTO
OFF
T/C AUTO
CAL
OFF
AUTOOFF
AOX2
ADMN2
AAV3
AAV3
ADMN2
AVG2
AOX2
COM
CAT.III 600V ~ 200μA MAX
MAX
HOLD
600
200
200
VAC
VDC
2000m
2000m
200m
MFD
200
Ω
200
200m
µADC
200
The Original Stick Meter
HS26
Opman HS26 v214