Download [MI 611-227] 875 Series Intelligent Analyzers - Operation

Transcript
MI 611-227
Instruction
October 2004
875 Series Intelligent Analyzers
Operation, Configuration, and Calibration
Using a HART Communicator
MI 611-227 – October 2004
Contents
1. General Information.......................................................................................................... 1
Description ............................................................................................................................... 1
Reference Documents ...............................................................................................................
Overview of Top Level Menus ..................................................................................................
Connecting the Communicator to the Analyzer ........................................................................
Communicator Keyboard and Display ......................................................................................
Offline Configuration ...............................................................................................................
Online Configuration ...............................................................................................................
1
1
2
3
3
3
2. 875PH Analyzer ................................................................................................................
Online Flowchart ......................................................................................................................
Online Modes ...........................................................................................................................
Measurement ........................................................................................................................
Status ...................................................................................................................................
Hold ....................................................................................................................................
Calibrate ...............................................................................................................................
Configure .............................................................................................................................
Diagnostics ...........................................................................................................................
Logon Passcode ....................................................................................................................
Explanation of Parameters .........................................................................................................
5
5
6
6
6
6
6
6
7
7
7
3. 875CR Analyzer ................................................................................................................ 9
Online Flowchart ...................................................................................................................... 9
Online Modes ......................................................................................................................... 10
Measurement ...................................................................................................................... 10
Status ................................................................................................................................. 10
Hold .................................................................................................................................. 10
Calibrate ............................................................................................................................. 10
Configure ........................................................................................................................... 11
Diagnostics ......................................................................................................................... 11
Logon Passcode .................................................................................................................. 11
Explanation of Parameters ....................................................................................................... 11
4. 875EC Analyzer ..............................................................................................................
Online Flowchart ....................................................................................................................
Online Modes .........................................................................................................................
Measurement ......................................................................................................................
Status .................................................................................................................................
Hold ..................................................................................................................................
Calibrate .............................................................................................................................
13
13
14
14
14
14
14
iii
MI 611-227 – October 2004
Contents
Configure ...........................................................................................................................
Diagnostics .........................................................................................................................
Logon Passcode ..................................................................................................................
Explanation of Parameters .......................................................................................................
14
15
15
15
5. Glossary of Online Parameters ........................................................................................ 17
iv
1. General Information
Description
The 875 Series Analyzers with HART communications may be configured, operated, and
calibrated using the HART Communicator.
The HART Communicator is used in two environments: Offline (not connected to an analyzer)
and Online (connected to an analyzer). The Main menu (shown in Figure 1) is displayed when
not connected to an analyzer. The Online Menu (shown in Figure 2) is displayed when connected
to an analyzer.
Reference Documents
This document contains information on configuration, calibration, and operation of the 875
Series Analyzers using a HART Communicator. Additional information about the analyzers and
the communicator is contained in the following documents:
Table 1. Reference Documents
Document
MI 611-222
MI 611-225
MI 611-224
MI 020-484
Description
875CR Intelligent Electrochemical Analyzer for Contacting
Conductivity and Resistivity Measurements
875PH Intelligent Electrochemical Analyzer for pH, ORP, or Ion Selective
Electrode (ISE) Measurement
875EC Intelligent Electrochemical Analyzer for Electrodeless Conductivity
Measurements
HART Model 275 Communicator Messages
Overview of Top Level Menus
Figure 1 shows the Main menu structure of the HART Communicator. Figure 2 shows the top
level Online menu for the 875 Series Analyzers.
1
MI 611-227 – October 2004
1. General Information
1. Offline
Compile a set of configuration data for downloading to an analyzer or
simulate an online connection to an analyzer without connecting to it.
2. Online
Configure, calibrate, or operate an online analyzer.
4. Frequency Device
Display the frequency output and pressure output of current to pressure
devices.
5. Utility
Configure communicator parameters such as auto polling and adjusting
contrast of communicator LCD. Also access to HART communicator
simulation
Figure 1. HART Communicator Main Menu
1 Measure
Display the measurement (process variable) and related data.
2 Status
Display the measurement and system parameters
3 Hold
Hold the output at a determined value
4 Calibrate
Perform calibration functions.
5 Config
Perform configuration functions
6 Diag
Perform diagnostic functions
7 Logon Passcode
Enter the passcode
Figure 2. 875 Series Analyzers Top Level Online Menu
Connecting the Communicator to the Analyzer
Connect the communicator or other HART I/O communication device to the COM1 and
COM2 terminals of the analyzer that are shown in MI 611-222, MI 611-224, or MI 611-225
supplied with the analyzer. There must also be a minimum of 250 Ω across the COM1 and
COM2 terminals.
2
1. General Information
MI 611-227 – October 2004
Communicator Keyboard and Display
Refer to the HART user manual supplied with the communicator.
Offline Configuration
The offline configuration feature is not available at this time.
Online Configuration
Refer to the following chapters:
875PH: Chapter 2
875CR: Chapter 3
875EC: Chapter 4
3
MI 611-227 – October 2004
4
1. General Information
2. 875PH Analyzer
Online Flowchart
2 Online
1 MEASURE
2 STATUS
3 HOLD
4 CALIBRATE
1 Meas
2 Abs
3 Temp
4 AO1
5 HART AO
1 Status
2 History Status
Off
On Present
On Manual
Save/Abort
Bench
Solution
Auto Service 1*
Auto Service 2*
Cal Analog
Logon Passcode
* if enabled
5 CONFIG
6 DIAG
1 View Faults
2 Resume Faults
3 View History
4 Erase History
5 Demand Report
6 DD Rev
7 Logon Passcode
Temp
Abs
ATC Resistance
Slope %
Slope mV
Asymmetry
Glass Bulb
Reference
Pre amp
Cal Person
Cal Date
Cal Type
Cal Temp
Cal Point One
Cal Point One
Cal Point Two
Cal Point Two
AO1
HART AO
Tag Name
Location
Sales Order
MS Code
Serial Number
Software Version
Dev Name
Model
Line Frequency
Time
Date
Save/Abort
Measurement
Sensor
Temp Comp
Display
Save/Abort
Analog 1
HART
Diags
Autoservice
Save/Abort
Alarms
Hold Config
Remote
Cal
Timeouts
Save/Abort
Date Time
Analyzer Names
Passcodes
LED Adjust
Save/Abort
Default
Logon Passcode
Figure 3. Online Configuration Flowchart
5
MI 611-227 – October 2004
2. 875PH Analyzer
Online Modes
Measurement
To display the measurement on the communicator, select 1 Measure from the Online menu.
The display will show:
1 Meas
The measurement value in engineering units.
2 Abs
The uncompensated measurement in millivolts.
3 Temp
The temperature measurement in engineering units.
4 A01
Analog Output 1 in mA.
5 HART AO HART Analog Output in mA.
You can then select what you wish to display.
Status
To display the status on the communicator, select 2 Status from the Online menu. You can then
select to view the Current Status or the History Status and view the status of a number of
parameters.
Hold
To access the Hold functions from the communicator, select 3 Hold from the Online menu.
Access requires you to have previously entered the proper passcode. You can then select Off to not
use the Hold function, Present to hold all values and states at their current value, and Manual to
set values and states at desired levels. In Manual, the Hold function does not take effect until all
the values are entered.
Calibrate
To access the Calibration functions from the communicator, select 4 Calibrate from the Online
menu. Access requires you to enter the proper passcode. You can then select Bench, Solution, or
Cal Analog calibration. You can also start Auto Service 1 or Auto Service 2 (if enabled). If
you select Cal Analog, you must further define the output as AO1 or HART.
NOTE
If Save/Abort appears in the Calibration menu, there are configuration changes
pending. Save/Abort must be selected before any calibration is allowed.
Configure
To access the Configuration functions from the communicator, select 5 Config from the Online
menu. Access requires you to enter the proper passcode. You can then configure a number of
parameters from the menu that is presented.
NOTE
Before leaving the Configure mode, you must activate Save/Abort if it is visible.
6
2. 875PH Analyzer
MI 611-227 – October 2004
Diagnostics
To access the Diagnostic functions from the communicator, select 6 Diag from the Online menu.
You can then select View Faults, Resume Faults, View History, Erase History, Demand
Report, or DD Rev. The proper passcode is required to suspend a fault or to erase the history log.
NOTE
The DD Rev may not change with upgrade to subsequent firmware versions.
Logon Passcode
To access certain functions from the HART Communicator, you must enter the Level 1, Level 2,
or Level 3 passcode (that was configured into the analyzer) into the HART Configurator. To do
this, select 7 Logon Passcode from the Online menu.
NOTE
7 Logon Passcode can also be used to ‘lock’ the analyzer by entering an invalid
passcode.
Explanation of Parameters
See “Glossary of Online Parameters” on page 17.
7
MI 611-227 – October 2004
8
2. 875PH Analyzer
3. 875CR Analyzer
Online Flowchart
2 Online
1 MEASURE
2 STATUS
3 HOLD
4 CALIBRATE
Meas
Abs
Temp
Meas 1*
Abs 1*
Temp 1*
Meas 2*
Abs 2*
Temp 2*
Rej*
Ratio*
Avg*
Diff*
AO1
HART AO
1 Status
2 History Status
Off
On Present
On Manual
1 Bench
2 Solution
3 Pure H2O
4 Cust Temp
5 Save/Abort
6 Cal Analog
7 Logon Passcode
5 CONFIG
6 DIAG
1 View Faults
2 Resume Faults
3 View History
4 Erase History
5 Demand Report
6 DD Rev
7 Logon Passcode
Temp
Abs
ATC Resistance
Temp 1*
Abs 1*
ATC Resistance 1*
Temp 2*
Abs 2*
ATC Resistance 2*
Cal Person
Cal Date
Cal Type
Cal Temp
AO1
HART AO
Tag Name
Location
Sales Order
MS Code
Serial Number
Software Version
Dev Name
Model
Line Frequency
Time
Date
Cell Mode
Cell
Cell 1*
Cell 2*
Save/Abort
No. Apps
Application
Remote
Cal
Save/Abort
Hold Config
Diags
Timeout
Date Time
Save/Abort
Analyzer Names
Passcodes
LCD Adjust
Default
Save/Abort
Logon Passcode
Measurement
Measurement 1*
1
Measurement 2*
Temp Comp
Temp Comp 1*
Temp Comp 2*
Display
Analog 1
HART
Alarm 1
Alarm 2
Logon Passcode
* Dual Cell Only
Figure 4. Online Configuration Flowchart
9
MI 611-227 – October 2004
3. 875CR Analyzer
Online Modes
Measurement
To display the measurement on the communicator, select 1 Measure from the Online menu.
The display will show:
Meas*
The measurement value in engineering units.
Abs*
The uncompensated measurement in millivolts.
Temp*
The temperature measurement in engineering units.
Rej
The percent rejection if dual cell.
Ratio
The measurement ratio if dual cell.
Avg
The average measurement of the two cells if dual cell.
Diff
The measurement difference of the two cells if dual cell.
A01
Analog Output 1 in mA.
HART AO
HART Analog Output in mA.
*For both Cell 1 and Cell 2 if dual cell.
You can then select what you wish to display.
Status
To display the status on the communicator, select 2 Status from the Online menu. You can then
select to view the Current Status or the History Status and view the status of a number of
parameters.
Hold
To access the Hold functions from the communicator, select 3 Hold from the Online menu.
Access requires you to have previously entered the proper passcode. You can then select Off to not
use the Hold function, Present to hold all values and states at their current value, and Manual to
set values and states at desired levels. In Manual, the Hold function does not take effect until all
the values are entered.
Calibrate
To access the Calibration functions from the communicator, select 4 Calibrate from the Online
menu. Access requires you to enter the proper passcode. You can then select Bench, Solution,
Pure H2O, Cust Temp, or Cal Analog calibration. If you select Cal Analog, you must further
define the output as AO1 or HART.
NOTE
If Save/Abort appears in the Calibration menu, there are configuration changes
pending. Save/Abort must be selected before any calibration is allowed.
10
3. 875CR Analyzer
MI 611-227 – October 2004
Configure
To access the Configuration functions from the communicator, select 5 Config from the Online
menu. Access requires you to enter the proper passcode. You can then configure a number of
parameters from the menu that is presented.
NOTE
Before leaving the Configure mode, you must activate Save/Abort if it is visible.
Diagnostics
To access the Diagnostic functions from the communicator, select 6 Diag from the Online menu.
You can then select View Faults, Resume Faults, View History, Erase History, Demand
Report, or DD Rev. The proper passcode is required to suspend a fault or to erase the history log.
NOTE
The DD Rev may not change with upgrade to subsequent firmware versions.
Logon Passcode
To access certain functions from the HART Communicator, you must enter the Level 1, Level 2,
or Level 3 passcode (that was configured into the analyzer) into the HART Configurator. To do
this, select 7 Logon Passcode from the Online menu.
NOTE
7 Logon Passcode can also be used to ‘lock’ the analyzer by entering an invalid
passcode.
Explanation of Parameters
See “Glossary of Online Parameters” on page 17.
11
MI 611-227 – October 2004
12
3. 875CR Analyzer
4. 875EC Analyzer
Online Flowchart
2 Online
1 MEASURE
2 STATUS
3 HOLD
4 CALIBRATE
1 Meas
2 Abs
3 Temp
4 AO1
5 HART AO
1 Status
2 History Status
Off
On Present
On Manual
1 Bench
2 Solution
3 Auto Service
4 Cal Analog
5 Save/Abort
6 Logon Passcode
5 CONFIG
6 DIAG
1. Temp
2. Abs
3. ATC Resistance
4. Cal Person
5. Cal Date
6. Cal Type
7. Cal Temp
8. AO1
9. HART AO
Tag Name
Location
Sales Order
MS Code
Serial Number
Software Version
Dev Name
Model
Line Frequency
Time
Date
1 View Faults
2 Resume Faults
3 View History
4 Erase History
5 Demand Report
6 DD Rev
7 Logon Passcode
Sensor
No. Apps
Application
Run Apps
Save/Abort
Remote
Cal
Hold Config
Diags
Save/Abort
Timeouts
Date Time
Analyzer Names
Passcodes
Save/Abort
LCD Adjust
Default
Logon Passcode
1 Measurement
2 Temp Comp
3 Display
4 Analog 1
5 HART
6 Auto Service
7 Alarm 1
8 Alarm 2
9 Logon Passcode
Figure 5. Online Configuration Flowchart
13
MI 611-227 – October 2004
4. 875EC Analyzer
Online Modes
Measurement
To display the measurement on the communicator, select 1 Measure from the Online menu.
The display will show:
1 Meas
The measurement value in engineering units.
2 Abs
The uncompensated measurement in millivolts.
3 Temp
The temperature measurement in engineering units.
4 A01
Analog Output 1 in mA.
5 HART AO HART Analog Output in mA.
You can then select what you wish to display.
Status
To display the status on the communicator, select 2 Status from the Online menu. You can then
select to view the Current Status or the History Status and view the status of a number of
parameters.
Hold
To access the Hold functions from the communicator, select 3 Hold from the Online menu.
Access requires you to have previously entered the proper passcode. You can then select Off to not
use the Hold function, Present to hold all values and states at their current value, and Manual to
set values and states at desired levels. In Manual, the Hold function does not take effect until all
the values are entered.
Calibrate
To access the Calibration functions from the communicator, select 4 Calibrate from the Online
menu. Access requires you to enter the proper passcode. You can then select Bench, Solution, or
Cal Analog calibration. If you select Cal Analog, you must further define the output as AO1 or
HART.
NOTE
If Save/Abort appears in the Calibration menu, there are configuration changes
pending. Save/Abort must be selected before any calibration is allowed.
Configure
To access the Configuration functions from the communicator, select 5 Config from the Online
menu. Access requires you to enter the proper passcode. You can then configure a number of
parameters from the menu that is presented.
NOTE
Before leaving the Configure mode, you must activate Save/Abort if it is visible.
14
4. 875EC Analyzer
MI 611-227 – October 2004
Diagnostics
To access the Diagnostic functions from the communicator, select 6 Diag from the Online menu.
You can then select View Faults, Resume Faults, View History, Erase History, Demand
Report, or DD Rev. The proper passcode is required to suspend a fault or to erase the history log.
NOTE
The DD Rev may not change with upgrade to subsequent firmware versions.
Logon Passcode
To access certain functions from the HART Communicator, you must enter the Level 1, Level 2,
or Level 3 passcode (that was configured into the analyzer) into the HART Configurator. To do
this, select 7 Logon Passcode from the Online menu.
NOTE
7 Logon Passcode can also be used to ‘lock’ the analyzer by entering an invalid
passcode.
Explanation of Parameters
See “Glossary of Online Parameters” on page 17.
15
MI 611-227 – October 2004
16
4. 875EC Analyzer
5. Glossary of Online Parameters
Parameter
Measure Mode
Abs
AO1 (a)
Avg
Diff
HART AO (a)
Meas
Ratio
Rej
Temp
Status Mode (b)
Abs
AO1
Asymmetry
ATC Resistance
Cal Date
Cal Person
Cal Point One
Cal Point Two
Cal Temp
Cal Type
Date
Dev Name
Glass Bulb
HART AO
Explanation
Applicable
Analyzers
Displays the absolute (uncompensated) measurement
Displays the Analog Output 1 measurement in mA or volts
Displays the average measurement of (cell 1 + cell 2) / 2
Displays the measurement difference
For conductivity, cell 1 - cell 2
For resistivity, cell 2 - cell 1
Displays the HART Analog Output measurement in mA
Displays the measurement in specified engineering units
Displays the measurement ratio
For conductivity, (cell 2 / cell 1) x 100
For resistivity, (cell 1 / cell 2) x 100
Displays the percent rejection
For conductivity, [1- (cell 2 / cell 1)] x 100
For resistivity, [1- (cell 1 / cell 2)] x 100
Displays the process temperature measurement in specified
engineering units
CR, EC, PH
CR, EC, PH
CR
CR
Displays the absolute measurement
Displays the value of Analog Output 1 in mA or volts
Displays the asymmetry potential (mV difference between the
theoretical isopotential point and the actual point due to the most
recent calibration
Displays the resistance of the temperature compensator
Displays the date of the last calibration in the form mm/dd/yy
Displays the name of the last calibrator
Displays the values at calibration point one in pH and then in mV
Displays the values at calibration point two in pH and then in mV
Displays the temperature calibration type of last calibration
(default, custom, solution, failsafe, manual)
Displays the type of the last calibration (bench, solution, factory
default)
Displays the current date
Displays the device name of the analyzer
Displays the glass bulb resistance
Displays the HART analog output in mA
CR, EC, PH
CR, EC, PH
PH
CR, EC, PH
CR, EC, PH
CR
CR
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
PH
PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
PH
CR, EC, PH
17
MI 611-227 – October 2004
Parameter
History Status
Line Frequency
Location
Model
MS Code
Pre amp
Reference
Sales Order
Serial Number
Slope %
Slope mV
5. Glossary of Online Parameters
Explanation
Displays up to 10 of the most current history log entries
(if present)
Displays the ac line frequency of the analyzer
Displays the location of the measurement
Displays the model number of the analyzer
Displays the analyzer model code
Displays the preamplifier power
Displays the reference junction resistance
Displays the analyzer sales order number
Displays the analyzer serial number
Displays the deviation in percent of the slope of the most recent
calibration compared to the standard
Displays the change in the mV/pH or mV/decade of the most
recent calibration
Displays the software version of the analyzer
Displays the current status of the analyzer
Displays the tag name of the analyzer
Displays the process temperature of the sensor
Displays the current time
Software Version
Status
Tag Name
Temp
Time
Hold Mode
Off
Used to release the analyzer from Hold state
On Manual
Used to hold all values and states at desired levels
On Present
Used to hold all values and states at their current level
(c)
Calibrate Mode
Auto Service n
Used to perform an automatic cleaning of the sensor and/or a 1point or 2-point calibration as configured
Bench
Used to perform a calibration using theoretical inputs or to return
to the stored factory default calibration
Cal Analog
Used to tune the 4 mA and 20 mA values of the AO1 or HART
analog outputs
Logon Passcode Used to enter the passcode to access Calibration mode
Pure H2O
Used to perform a pure water calibration.
Solution
Used to perform a calibration using real solutions
Config Mode
Alarms
Used to specify each alarm to represent measurement, temperature,
absolute, or a fault and then subparameters associated with each
Analog 1
Used to specify the Analog 1 output to represent measurement,
temperature, or absolute; minimum (LRV) and maximum (URV)
range values; and failsafe output
(e) Used to specify the tag number, tag name, location, and device
Analyzer Names
name
18
Applicable
Analyzers
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
PH
PH
CR, EC, PH
CR, EC, PH
PH
PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
PH, EC
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR
CR, EC, PH
CR, PH, EC
CR, PH, EC
CR, EC, PH
5. Glossary of Online Parameters
Parameter
Application
Auto Service (d)
Cal
Cell
Cell Mode
Datetime
Default
Diags
Display
HART
Hold Config
LED Adjust
Logon Passcode
Measurement
No. Apps
Passcodes
Remote
Run Apps
Sensor
Temp Comp
Timeouts
Diag Mode
DD Rev
Demand Report
Erase History
MI 611-227 – October 2004
Explanation
Used to specify the measurement, display, temperature
compensation, output, and alarm configuration for each
application.
Used to configure auto service related parameters
Used to specify the options to be used with a solution calibration
Used to specify the cell constant and temperature features for all
three applications
Used to specify cell mode as Single, Dual, or Redundant
Used to set the date and time for the real time clock
Used to reset the configuration back to the factory default values
Used to specify what fault messages can appear on your display
Used to configure the display as single, dual, or scan and then
subparameters associated with each
Used to specify the HART output to represent measurement,
temperature, or absolute; minimum (LRV) and maximum (URV)
range values; and failsafe output.
Also used to specify the Polling Address and the Preambles value.
Used to configure all values and states to be held at their current
level (On Present) or at a desired level (On Manual) when triggered
by a digital signal or when going into Calibration or Configuration
mode
Used to adjust the brightness of the front panel display
Used to enter the passcode to access Configuration mode
Used to configure units, damping, and other measurement
parameters
Used to specify the number of applications you wish to
preconfigure.
Used to establish or change the Level 1, 2, and 3 passcodes
Used to configure parameters associated with a remote personal
computer or RS232 printer
Used to switch form one application to another
Used to configure sensor related parameters
Used to configure the temperature compensation for the chemical
being measured
Used to specify the time for front panel, remote, and digital
communication timeouts
Used to display the DD version
Used to send the history log out to the remote RS232 port
Used to erase the history log (requires Level 1 passcode)
Applicable
Analyzers
CR, EC
PH, EC
CR, EC, PH
CR
CR
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, PH, EC
CR, PH, EC
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, PH, EC
CR, EC
CR, EC, PH
CR, EC, PH
CR, EC
PH, EC
CR, PH, EC
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
19
MI 611-227 – October 2004
5. Glossary of Online Parameters
Parameter
Logon Passcode
Explanation
Used to enter the passcode to perform functions requiring a
passcode
Logon Passcode Mode
Resume Faults
Used to resume any suspended faults
View Faults
Used to view any faults and possibly suspend each fault
View History
Used to view the diagnostic history
Applicable
Analyzers
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
CR, EC, PH
(a) If configured Off, display reads NaN.
(b) At message “Ignore next 50 occurrences of status?”, reply “YES”.
(c) If a disconnect occurs during calibration, recycle power or attempt another calibration.
(d) Auto Service monthly must schedule days 16 at a time in two entries.
(e) Use upper case letters for Tag Number.
ISSUE DATES
JUN 2003
OCT 2004
Vertical lines to right of text or illustrations indicate areas changed at last issue date.
33 Commercial Street
Foxboro, MA 02035-2099
United States of America
http://www.foxboro.com
Inside U.S.:
1-866-746-6477
Outside U.S.: 1-508-549-2424
or contact your local Foxboro
Representative.
Facsimile: (508) 549-4492
Invensys and Foxboro are trademarks of Invensys plc, its subsidiaries, and affiliates.
All other brand names may be trademarks of their respective owners.
Copyright 2003-2004 Invensys Systems, Inc.
All rights reserved
MB 123
Printed in U.S.A.
1004