Download [MI 611-227] 875 Series Intelligent Analyzers - Operation
Transcript
MI 611-227 Instruction October 2004 875 Series Intelligent Analyzers Operation, Configuration, and Calibration Using a HART Communicator MI 611-227 – October 2004 Contents 1. General Information.......................................................................................................... 1 Description ............................................................................................................................... 1 Reference Documents ............................................................................................................... Overview of Top Level Menus .................................................................................................. Connecting the Communicator to the Analyzer ........................................................................ Communicator Keyboard and Display ...................................................................................... Offline Configuration ............................................................................................................... Online Configuration ............................................................................................................... 1 1 2 3 3 3 2. 875PH Analyzer ................................................................................................................ Online Flowchart ...................................................................................................................... Online Modes ........................................................................................................................... Measurement ........................................................................................................................ Status ................................................................................................................................... Hold .................................................................................................................................... Calibrate ............................................................................................................................... Configure ............................................................................................................................. Diagnostics ........................................................................................................................... Logon Passcode .................................................................................................................... Explanation of Parameters ......................................................................................................... 5 5 6 6 6 6 6 6 7 7 7 3. 875CR Analyzer ................................................................................................................ 9 Online Flowchart ...................................................................................................................... 9 Online Modes ......................................................................................................................... 10 Measurement ...................................................................................................................... 10 Status ................................................................................................................................. 10 Hold .................................................................................................................................. 10 Calibrate ............................................................................................................................. 10 Configure ........................................................................................................................... 11 Diagnostics ......................................................................................................................... 11 Logon Passcode .................................................................................................................. 11 Explanation of Parameters ....................................................................................................... 11 4. 875EC Analyzer .............................................................................................................. Online Flowchart .................................................................................................................... Online Modes ......................................................................................................................... Measurement ...................................................................................................................... Status ................................................................................................................................. Hold .................................................................................................................................. Calibrate ............................................................................................................................. 13 13 14 14 14 14 14 iii MI 611-227 – October 2004 Contents Configure ........................................................................................................................... Diagnostics ......................................................................................................................... Logon Passcode .................................................................................................................. Explanation of Parameters ....................................................................................................... 14 15 15 15 5. Glossary of Online Parameters ........................................................................................ 17 iv 1. General Information Description The 875 Series Analyzers with HART communications may be configured, operated, and calibrated using the HART Communicator. The HART Communicator is used in two environments: Offline (not connected to an analyzer) and Online (connected to an analyzer). The Main menu (shown in Figure 1) is displayed when not connected to an analyzer. The Online Menu (shown in Figure 2) is displayed when connected to an analyzer. Reference Documents This document contains information on configuration, calibration, and operation of the 875 Series Analyzers using a HART Communicator. Additional information about the analyzers and the communicator is contained in the following documents: Table 1. Reference Documents Document MI 611-222 MI 611-225 MI 611-224 MI 020-484 Description 875CR Intelligent Electrochemical Analyzer for Contacting Conductivity and Resistivity Measurements 875PH Intelligent Electrochemical Analyzer for pH, ORP, or Ion Selective Electrode (ISE) Measurement 875EC Intelligent Electrochemical Analyzer for Electrodeless Conductivity Measurements HART Model 275 Communicator Messages Overview of Top Level Menus Figure 1 shows the Main menu structure of the HART Communicator. Figure 2 shows the top level Online menu for the 875 Series Analyzers. 1 MI 611-227 – October 2004 1. General Information 1. Offline Compile a set of configuration data for downloading to an analyzer or simulate an online connection to an analyzer without connecting to it. 2. Online Configure, calibrate, or operate an online analyzer. 4. Frequency Device Display the frequency output and pressure output of current to pressure devices. 5. Utility Configure communicator parameters such as auto polling and adjusting contrast of communicator LCD. Also access to HART communicator simulation Figure 1. HART Communicator Main Menu 1 Measure Display the measurement (process variable) and related data. 2 Status Display the measurement and system parameters 3 Hold Hold the output at a determined value 4 Calibrate Perform calibration functions. 5 Config Perform configuration functions 6 Diag Perform diagnostic functions 7 Logon Passcode Enter the passcode Figure 2. 875 Series Analyzers Top Level Online Menu Connecting the Communicator to the Analyzer Connect the communicator or other HART I/O communication device to the COM1 and COM2 terminals of the analyzer that are shown in MI 611-222, MI 611-224, or MI 611-225 supplied with the analyzer. There must also be a minimum of 250 Ω across the COM1 and COM2 terminals. 2 1. General Information MI 611-227 – October 2004 Communicator Keyboard and Display Refer to the HART user manual supplied with the communicator. Offline Configuration The offline configuration feature is not available at this time. Online Configuration Refer to the following chapters: 875PH: Chapter 2 875CR: Chapter 3 875EC: Chapter 4 3 MI 611-227 – October 2004 4 1. General Information 2. 875PH Analyzer Online Flowchart 2 Online 1 MEASURE 2 STATUS 3 HOLD 4 CALIBRATE 1 Meas 2 Abs 3 Temp 4 AO1 5 HART AO 1 Status 2 History Status Off On Present On Manual Save/Abort Bench Solution Auto Service 1* Auto Service 2* Cal Analog Logon Passcode * if enabled 5 CONFIG 6 DIAG 1 View Faults 2 Resume Faults 3 View History 4 Erase History 5 Demand Report 6 DD Rev 7 Logon Passcode Temp Abs ATC Resistance Slope % Slope mV Asymmetry Glass Bulb Reference Pre amp Cal Person Cal Date Cal Type Cal Temp Cal Point One Cal Point One Cal Point Two Cal Point Two AO1 HART AO Tag Name Location Sales Order MS Code Serial Number Software Version Dev Name Model Line Frequency Time Date Save/Abort Measurement Sensor Temp Comp Display Save/Abort Analog 1 HART Diags Autoservice Save/Abort Alarms Hold Config Remote Cal Timeouts Save/Abort Date Time Analyzer Names Passcodes LED Adjust Save/Abort Default Logon Passcode Figure 3. Online Configuration Flowchart 5 MI 611-227 – October 2004 2. 875PH Analyzer Online Modes Measurement To display the measurement on the communicator, select 1 Measure from the Online menu. The display will show: 1 Meas The measurement value in engineering units. 2 Abs The uncompensated measurement in millivolts. 3 Temp The temperature measurement in engineering units. 4 A01 Analog Output 1 in mA. 5 HART AO HART Analog Output in mA. You can then select what you wish to display. Status To display the status on the communicator, select 2 Status from the Online menu. You can then select to view the Current Status or the History Status and view the status of a number of parameters. Hold To access the Hold functions from the communicator, select 3 Hold from the Online menu. Access requires you to have previously entered the proper passcode. You can then select Off to not use the Hold function, Present to hold all values and states at their current value, and Manual to set values and states at desired levels. In Manual, the Hold function does not take effect until all the values are entered. Calibrate To access the Calibration functions from the communicator, select 4 Calibrate from the Online menu. Access requires you to enter the proper passcode. You can then select Bench, Solution, or Cal Analog calibration. You can also start Auto Service 1 or Auto Service 2 (if enabled). If you select Cal Analog, you must further define the output as AO1 or HART. NOTE If Save/Abort appears in the Calibration menu, there are configuration changes pending. Save/Abort must be selected before any calibration is allowed. Configure To access the Configuration functions from the communicator, select 5 Config from the Online menu. Access requires you to enter the proper passcode. You can then configure a number of parameters from the menu that is presented. NOTE Before leaving the Configure mode, you must activate Save/Abort if it is visible. 6 2. 875PH Analyzer MI 611-227 – October 2004 Diagnostics To access the Diagnostic functions from the communicator, select 6 Diag from the Online menu. You can then select View Faults, Resume Faults, View History, Erase History, Demand Report, or DD Rev. The proper passcode is required to suspend a fault or to erase the history log. NOTE The DD Rev may not change with upgrade to subsequent firmware versions. Logon Passcode To access certain functions from the HART Communicator, you must enter the Level 1, Level 2, or Level 3 passcode (that was configured into the analyzer) into the HART Configurator. To do this, select 7 Logon Passcode from the Online menu. NOTE 7 Logon Passcode can also be used to ‘lock’ the analyzer by entering an invalid passcode. Explanation of Parameters See “Glossary of Online Parameters” on page 17. 7 MI 611-227 – October 2004 8 2. 875PH Analyzer 3. 875CR Analyzer Online Flowchart 2 Online 1 MEASURE 2 STATUS 3 HOLD 4 CALIBRATE Meas Abs Temp Meas 1* Abs 1* Temp 1* Meas 2* Abs 2* Temp 2* Rej* Ratio* Avg* Diff* AO1 HART AO 1 Status 2 History Status Off On Present On Manual 1 Bench 2 Solution 3 Pure H2O 4 Cust Temp 5 Save/Abort 6 Cal Analog 7 Logon Passcode 5 CONFIG 6 DIAG 1 View Faults 2 Resume Faults 3 View History 4 Erase History 5 Demand Report 6 DD Rev 7 Logon Passcode Temp Abs ATC Resistance Temp 1* Abs 1* ATC Resistance 1* Temp 2* Abs 2* ATC Resistance 2* Cal Person Cal Date Cal Type Cal Temp AO1 HART AO Tag Name Location Sales Order MS Code Serial Number Software Version Dev Name Model Line Frequency Time Date Cell Mode Cell Cell 1* Cell 2* Save/Abort No. Apps Application Remote Cal Save/Abort Hold Config Diags Timeout Date Time Save/Abort Analyzer Names Passcodes LCD Adjust Default Save/Abort Logon Passcode Measurement Measurement 1* 1 Measurement 2* Temp Comp Temp Comp 1* Temp Comp 2* Display Analog 1 HART Alarm 1 Alarm 2 Logon Passcode * Dual Cell Only Figure 4. Online Configuration Flowchart 9 MI 611-227 – October 2004 3. 875CR Analyzer Online Modes Measurement To display the measurement on the communicator, select 1 Measure from the Online menu. The display will show: Meas* The measurement value in engineering units. Abs* The uncompensated measurement in millivolts. Temp* The temperature measurement in engineering units. Rej The percent rejection if dual cell. Ratio The measurement ratio if dual cell. Avg The average measurement of the two cells if dual cell. Diff The measurement difference of the two cells if dual cell. A01 Analog Output 1 in mA. HART AO HART Analog Output in mA. *For both Cell 1 and Cell 2 if dual cell. You can then select what you wish to display. Status To display the status on the communicator, select 2 Status from the Online menu. You can then select to view the Current Status or the History Status and view the status of a number of parameters. Hold To access the Hold functions from the communicator, select 3 Hold from the Online menu. Access requires you to have previously entered the proper passcode. You can then select Off to not use the Hold function, Present to hold all values and states at their current value, and Manual to set values and states at desired levels. In Manual, the Hold function does not take effect until all the values are entered. Calibrate To access the Calibration functions from the communicator, select 4 Calibrate from the Online menu. Access requires you to enter the proper passcode. You can then select Bench, Solution, Pure H2O, Cust Temp, or Cal Analog calibration. If you select Cal Analog, you must further define the output as AO1 or HART. NOTE If Save/Abort appears in the Calibration menu, there are configuration changes pending. Save/Abort must be selected before any calibration is allowed. 10 3. 875CR Analyzer MI 611-227 – October 2004 Configure To access the Configuration functions from the communicator, select 5 Config from the Online menu. Access requires you to enter the proper passcode. You can then configure a number of parameters from the menu that is presented. NOTE Before leaving the Configure mode, you must activate Save/Abort if it is visible. Diagnostics To access the Diagnostic functions from the communicator, select 6 Diag from the Online menu. You can then select View Faults, Resume Faults, View History, Erase History, Demand Report, or DD Rev. The proper passcode is required to suspend a fault or to erase the history log. NOTE The DD Rev may not change with upgrade to subsequent firmware versions. Logon Passcode To access certain functions from the HART Communicator, you must enter the Level 1, Level 2, or Level 3 passcode (that was configured into the analyzer) into the HART Configurator. To do this, select 7 Logon Passcode from the Online menu. NOTE 7 Logon Passcode can also be used to ‘lock’ the analyzer by entering an invalid passcode. Explanation of Parameters See “Glossary of Online Parameters” on page 17. 11 MI 611-227 – October 2004 12 3. 875CR Analyzer 4. 875EC Analyzer Online Flowchart 2 Online 1 MEASURE 2 STATUS 3 HOLD 4 CALIBRATE 1 Meas 2 Abs 3 Temp 4 AO1 5 HART AO 1 Status 2 History Status Off On Present On Manual 1 Bench 2 Solution 3 Auto Service 4 Cal Analog 5 Save/Abort 6 Logon Passcode 5 CONFIG 6 DIAG 1. Temp 2. Abs 3. ATC Resistance 4. Cal Person 5. Cal Date 6. Cal Type 7. Cal Temp 8. AO1 9. HART AO Tag Name Location Sales Order MS Code Serial Number Software Version Dev Name Model Line Frequency Time Date 1 View Faults 2 Resume Faults 3 View History 4 Erase History 5 Demand Report 6 DD Rev 7 Logon Passcode Sensor No. Apps Application Run Apps Save/Abort Remote Cal Hold Config Diags Save/Abort Timeouts Date Time Analyzer Names Passcodes Save/Abort LCD Adjust Default Logon Passcode 1 Measurement 2 Temp Comp 3 Display 4 Analog 1 5 HART 6 Auto Service 7 Alarm 1 8 Alarm 2 9 Logon Passcode Figure 5. Online Configuration Flowchart 13 MI 611-227 – October 2004 4. 875EC Analyzer Online Modes Measurement To display the measurement on the communicator, select 1 Measure from the Online menu. The display will show: 1 Meas The measurement value in engineering units. 2 Abs The uncompensated measurement in millivolts. 3 Temp The temperature measurement in engineering units. 4 A01 Analog Output 1 in mA. 5 HART AO HART Analog Output in mA. You can then select what you wish to display. Status To display the status on the communicator, select 2 Status from the Online menu. You can then select to view the Current Status or the History Status and view the status of a number of parameters. Hold To access the Hold functions from the communicator, select 3 Hold from the Online menu. Access requires you to have previously entered the proper passcode. You can then select Off to not use the Hold function, Present to hold all values and states at their current value, and Manual to set values and states at desired levels. In Manual, the Hold function does not take effect until all the values are entered. Calibrate To access the Calibration functions from the communicator, select 4 Calibrate from the Online menu. Access requires you to enter the proper passcode. You can then select Bench, Solution, or Cal Analog calibration. If you select Cal Analog, you must further define the output as AO1 or HART. NOTE If Save/Abort appears in the Calibration menu, there are configuration changes pending. Save/Abort must be selected before any calibration is allowed. Configure To access the Configuration functions from the communicator, select 5 Config from the Online menu. Access requires you to enter the proper passcode. You can then configure a number of parameters from the menu that is presented. NOTE Before leaving the Configure mode, you must activate Save/Abort if it is visible. 14 4. 875EC Analyzer MI 611-227 – October 2004 Diagnostics To access the Diagnostic functions from the communicator, select 6 Diag from the Online menu. You can then select View Faults, Resume Faults, View History, Erase History, Demand Report, or DD Rev. The proper passcode is required to suspend a fault or to erase the history log. NOTE The DD Rev may not change with upgrade to subsequent firmware versions. Logon Passcode To access certain functions from the HART Communicator, you must enter the Level 1, Level 2, or Level 3 passcode (that was configured into the analyzer) into the HART Configurator. To do this, select 7 Logon Passcode from the Online menu. NOTE 7 Logon Passcode can also be used to ‘lock’ the analyzer by entering an invalid passcode. Explanation of Parameters See “Glossary of Online Parameters” on page 17. 15 MI 611-227 – October 2004 16 4. 875EC Analyzer 5. Glossary of Online Parameters Parameter Measure Mode Abs AO1 (a) Avg Diff HART AO (a) Meas Ratio Rej Temp Status Mode (b) Abs AO1 Asymmetry ATC Resistance Cal Date Cal Person Cal Point One Cal Point Two Cal Temp Cal Type Date Dev Name Glass Bulb HART AO Explanation Applicable Analyzers Displays the absolute (uncompensated) measurement Displays the Analog Output 1 measurement in mA or volts Displays the average measurement of (cell 1 + cell 2) / 2 Displays the measurement difference For conductivity, cell 1 - cell 2 For resistivity, cell 2 - cell 1 Displays the HART Analog Output measurement in mA Displays the measurement in specified engineering units Displays the measurement ratio For conductivity, (cell 2 / cell 1) x 100 For resistivity, (cell 1 / cell 2) x 100 Displays the percent rejection For conductivity, [1- (cell 2 / cell 1)] x 100 For resistivity, [1- (cell 1 / cell 2)] x 100 Displays the process temperature measurement in specified engineering units CR, EC, PH CR, EC, PH CR CR Displays the absolute measurement Displays the value of Analog Output 1 in mA or volts Displays the asymmetry potential (mV difference between the theoretical isopotential point and the actual point due to the most recent calibration Displays the resistance of the temperature compensator Displays the date of the last calibration in the form mm/dd/yy Displays the name of the last calibrator Displays the values at calibration point one in pH and then in mV Displays the values at calibration point two in pH and then in mV Displays the temperature calibration type of last calibration (default, custom, solution, failsafe, manual) Displays the type of the last calibration (bench, solution, factory default) Displays the current date Displays the device name of the analyzer Displays the glass bulb resistance Displays the HART analog output in mA CR, EC, PH CR, EC, PH PH CR, EC, PH CR, EC, PH CR CR CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH PH PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH PH CR, EC, PH 17 MI 611-227 – October 2004 Parameter History Status Line Frequency Location Model MS Code Pre amp Reference Sales Order Serial Number Slope % Slope mV 5. Glossary of Online Parameters Explanation Displays up to 10 of the most current history log entries (if present) Displays the ac line frequency of the analyzer Displays the location of the measurement Displays the model number of the analyzer Displays the analyzer model code Displays the preamplifier power Displays the reference junction resistance Displays the analyzer sales order number Displays the analyzer serial number Displays the deviation in percent of the slope of the most recent calibration compared to the standard Displays the change in the mV/pH or mV/decade of the most recent calibration Displays the software version of the analyzer Displays the current status of the analyzer Displays the tag name of the analyzer Displays the process temperature of the sensor Displays the current time Software Version Status Tag Name Temp Time Hold Mode Off Used to release the analyzer from Hold state On Manual Used to hold all values and states at desired levels On Present Used to hold all values and states at their current level (c) Calibrate Mode Auto Service n Used to perform an automatic cleaning of the sensor and/or a 1point or 2-point calibration as configured Bench Used to perform a calibration using theoretical inputs or to return to the stored factory default calibration Cal Analog Used to tune the 4 mA and 20 mA values of the AO1 or HART analog outputs Logon Passcode Used to enter the passcode to access Calibration mode Pure H2O Used to perform a pure water calibration. Solution Used to perform a calibration using real solutions Config Mode Alarms Used to specify each alarm to represent measurement, temperature, absolute, or a fault and then subparameters associated with each Analog 1 Used to specify the Analog 1 output to represent measurement, temperature, or absolute; minimum (LRV) and maximum (URV) range values; and failsafe output (e) Used to specify the tag number, tag name, location, and device Analyzer Names name 18 Applicable Analyzers CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH PH PH CR, EC, PH CR, EC, PH PH PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH PH, EC CR, EC, PH CR, EC, PH CR, EC, PH CR CR, EC, PH CR, PH, EC CR, PH, EC CR, EC, PH 5. Glossary of Online Parameters Parameter Application Auto Service (d) Cal Cell Cell Mode Datetime Default Diags Display HART Hold Config LED Adjust Logon Passcode Measurement No. Apps Passcodes Remote Run Apps Sensor Temp Comp Timeouts Diag Mode DD Rev Demand Report Erase History MI 611-227 – October 2004 Explanation Used to specify the measurement, display, temperature compensation, output, and alarm configuration for each application. Used to configure auto service related parameters Used to specify the options to be used with a solution calibration Used to specify the cell constant and temperature features for all three applications Used to specify cell mode as Single, Dual, or Redundant Used to set the date and time for the real time clock Used to reset the configuration back to the factory default values Used to specify what fault messages can appear on your display Used to configure the display as single, dual, or scan and then subparameters associated with each Used to specify the HART output to represent measurement, temperature, or absolute; minimum (LRV) and maximum (URV) range values; and failsafe output. Also used to specify the Polling Address and the Preambles value. Used to configure all values and states to be held at their current level (On Present) or at a desired level (On Manual) when triggered by a digital signal or when going into Calibration or Configuration mode Used to adjust the brightness of the front panel display Used to enter the passcode to access Configuration mode Used to configure units, damping, and other measurement parameters Used to specify the number of applications you wish to preconfigure. Used to establish or change the Level 1, 2, and 3 passcodes Used to configure parameters associated with a remote personal computer or RS232 printer Used to switch form one application to another Used to configure sensor related parameters Used to configure the temperature compensation for the chemical being measured Used to specify the time for front panel, remote, and digital communication timeouts Used to display the DD version Used to send the history log out to the remote RS232 port Used to erase the history log (requires Level 1 passcode) Applicable Analyzers CR, EC PH, EC CR, EC, PH CR CR CR, EC, PH CR, EC, PH CR, EC, PH CR, PH, EC CR, PH, EC CR, EC, PH CR, EC, PH CR, EC, PH CR, PH, EC CR, EC CR, EC, PH CR, EC, PH CR, EC PH, EC CR, PH, EC CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH 19 MI 611-227 – October 2004 5. Glossary of Online Parameters Parameter Logon Passcode Explanation Used to enter the passcode to perform functions requiring a passcode Logon Passcode Mode Resume Faults Used to resume any suspended faults View Faults Used to view any faults and possibly suspend each fault View History Used to view the diagnostic history Applicable Analyzers CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH CR, EC, PH (a) If configured Off, display reads NaN. (b) At message “Ignore next 50 occurrences of status?”, reply “YES”. (c) If a disconnect occurs during calibration, recycle power or attempt another calibration. (d) Auto Service monthly must schedule days 16 at a time in two entries. (e) Use upper case letters for Tag Number. ISSUE DATES JUN 2003 OCT 2004 Vertical lines to right of text or illustrations indicate areas changed at last issue date. 33 Commercial Street Foxboro, MA 02035-2099 United States of America http://www.foxboro.com Inside U.S.: 1-866-746-6477 Outside U.S.: 1-508-549-2424 or contact your local Foxboro Representative. Facsimile: (508) 549-4492 Invensys and Foxboro are trademarks of Invensys plc, its subsidiaries, and affiliates. All other brand names may be trademarks of their respective owners. Copyright 2003-2004 Invensys Systems, Inc. All rights reserved MB 123 Printed in U.S.A. 1004