LogLock 3000/Mini v3.58
Attendance and Access Control System
User Manual, October 10, 2013, Rev. 53
Copyright © 2002-2013 by ASPiSYS Ltd.
Hardware and Firmware designed by:
ASPiSYS Ltd.
P.O. Box 14386, Athens 11510, GREECE (EU)
http://www.aspisys.com
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
1
Thank you for purchasing the all-new LogLock by ASPiSYS Ltd, an electronics design
and manufacturing company. All systems are designed by us and manufactured in the
EU.
This manual covers both LogLock 3000 (the larger PCB) and LogLock Mini (the
smaller UNiLOCK-sized PCB)1. For most practical purposes, these two are identical
but a few minor differences do exist. This document refers to either system as simply
LogLock, and where there are differences, they are noted.
LogLock is a sophisticated, highly reliable, stand-alone access control and/or timeattendance system for use at homes, schools, universities, hospitals, and in almost any
size business, from very small to quite large. LogLock is an enhanced version of the
older LogLock 2000 product and it is in most ways identical to previous versions but
offers additional functionality. User and log capacity is different, however, while
several user/log ratios are possible upon ordering. The major differences with LogLock
2000 are the lack of the PIN capability, and the smaller overall user/log file sizes. In
most respects, however, LogLock outperforms LogLock 2000 both in features and
speed; to name a few, various ordering options for up to 3520 maximum users, about 10
times faster overall speed (e.g., searches), 6 times faster log retrievals due to
significantly increased internal baud rate, alarm connection capability, and, very
importantly, simple fail-proof over-the-network firmware updates without loss of
current users and log.
Because of the entry/exit ‘audit trail’ capability in a single device, one can use any
LogLock system not only to control access, but also as an attendance clock, or as a
‘tracking’ system for access to sensitive resources (e.g. computer room, machinery
room, office supplies locker, etc.)
Due to the various versions available, some commands or capabilities may not be
enabled or active in all versions. For example, the sound option is not available in the
smaller LogLock Mini version. Also, although both PCB versions support the
connection of a 20x4 LCD (for date/time, and user ID/name display during entry or
exit), one may not be offered with all versions, mostly depending on the enclosure used.
Unless other arrangements are made in advance, both systems are currently available
in PCB format (without a specific enclosure). LogLock Mini’s dimensions are 100%
compatible to our simpler UNiLOCK product, so a UNiLOCK enclosure is readily
available, on request.
1
See drawings at the end of this document
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
2
About the keys
LogLock uses factory-guaranteed non-copiable world-unique electronic keys from
stainless steel (known as iButtons ®2) to identify each user. Each user need only be
given a single key regardless of the number of access points (LogLock or UNiLOCK
units – our other system) installed at one’s premises. Unlike ‘credit card’-like keys,
iButtons can withstand heavy abuse including extreme levels of heat, cold, and
moisture. One can step on them or even take them into water. They are virtually
indestructible. All types of iButtons can be used with LogLock without affecting thirdparty systems these iButtons may be used with.
General Characteristics / Capacity3
The two major characteristics of LogLock are reliability and ease of use. Just touch the
special battery-free electronic key to the corresponding key reader, and (if you meet all
access control requirements) you’re in, all in less than one second.
LogLock uses a highly optimized real-time multitasking Operating System (our own
OS8) which makes it possible to have the system operate continuously (except during
firmware updates), even when making changes or retrieving the log through the
terminal. Compare this to many competitor systems where the main functions must be
suspended during log retrieval or system configuration.
LogLock is completely stand-alone, meaning that once programmed with its various
parameters, user database, and access control rights, no further connection to a PC is
required for operation. A PC is only required to make configuration changes or to
retrieve the log.
The wrapping log keeps as many of the most recent actions as can fit in the device. This
means, one may leave the device unattended and only connect to it to retrieve the log
when there is need (e.g., for payroll use, a once-a-month connection may be enough in
many situations).
The system has a built-in calendar clock backed by a user-replaceable battery
(CR2032/CR2025). The clock auto-switches from/to DST based on EU rules.
2
3
iButton is a registered trademark of Maxim Integrated Products/Dallas Semiconductor
Specifications are subject to change without prior notice.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
3
One significant feature of LogLock that sets it apart from most, if not all, competition is
that the complete operating software is built-in, and it uses plain language commands.
No special PC software is required; any telnet terminal emulator will do. This means,
the system is not tied to a specific computer platform. It can be connected to from any
operating system, as long as it has a telnet application (practically all do). One can even
connect from a smart [cell] phone with a telnet application4. Strong 20-char userdefined passwords with 5-sec delays on each failed attempt protect from unauthorized
terminal access.
Because of the standard Ethernet connectivity, the device can participate in a larger
network and, therefore, connected to from any part of the world5. As an example, one
can have hundreds or thousands of units deployed all over the world, all fully managed
from a single location.
Even firmware upgrades can be performed from a distance, without placing the
controlled area at risk during the upgrade procedure, as the system defaults to no access
during such times. Firmware upgrades take less than a minute to complete not causing
any major downtime.
One important feature of the system is the use of ‘passive’ key readers (i.e., they contain
no electronic circuit) that are simple and nearly cost-free, while the actual system is
always securely installed inside the protected area. One may also connect in parallel
two (or more) readers so that if the main (obvious) reader is ever vandalized, one can
still use another reader (placed somewhere less obvious and less easy to reach) to gain
access. With most competitor systems (especially those not based on the iButton
technology), the reader is active (contains electronic circuit) and, if it breaks, the system
becomes non-functional until the reader is repaired or replaced.
Another important feature of LogLock is the ability of a single device to control up to
two doors, one for both entry and exit, or one for entry and a different one for exit. This
is mostly useful for garage or one-way turnstile installations.
Only one device is needed to control both sides of the door. Compare that to many
competitor systems which require a unit on each side of the door, increasing both cost
and installation complexity. With LogLock, only a single pair of wires need to cross the
wall to the outside. The wires themselves can act as a reader if the actual reader is
vandalized.
In the default OEM configuration, each LogLock device can hold up to 448 unique users
(keys), each with their own name and optional zone access restrictions, and a wrapping
log of up to 5733 actions.
Note: If a version with a larger number of maximum keys is requested this will most
likely affect the maximum possible log size. For example, for 896 users, the available
4
5
A data plan and service availability is required. Charges may apply and depend on one’s service plan.
Internet connectivity is required in this case.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
4
log is 4485. Because memory size is fixed, as one file size increases (maximum users
and/or username length) another decreases (maximum log) and vice versa. This
manual references file sizes for the default version. If ordering a different version,
please specify your actual user requirements taking into account possible near future
increases in user population.
Each time a verified user enters or exits the controlled area, LogLock records the date,
time, direction, and unique user ID while striking the door open. This allows the owner
or manager of the system to figure out how much time people spent inside, or simply see
when they showed up to work. One can optionally have the device record both
successful and unsuccessful attempts from registered users. This feature lets one see if
anyone attempted to enter outside of his or her approved ‘shift’.
When a key is either lost or stolen, the user should be deactivated from the system. This
renders the key totally useless to whoever has it, and the original user can replace it with
a new one.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
5
In short, these are the features of the LogLock system.
Maximum unique keys (people):
Maximum day-of-week/time zones:
Special fixed zones:
Maximum fixed holidays:
Maximum entry/exit recordings:
Languages supported:
Door-open delay setting:
Door-strike mode:
Alarm mode:
Sounds/Beeps:
PIN mode:
Password protection:
448 (default) to 3520 (depends on version)
1020 zone entries (in up to 254 zones)
‘Always Allowed’ (0) & ‘Never Allowed’ (255)
256 entered as DDMM
5733 with most recent 5695 always available
(depends on version).
Note: The maximum log size may be smaller in
versions with greater number of maximum keys.
English (anywhere) or Greek (LCD and user
names in listings only).
For larger orders, we may be able to replace
Greek with another language, on request.
0 (strike disabled) to 25.5 seconds with 1/10th of a
second resolution. The delay is entered as integer;
for example, for 1.5 seconds, enter 15 (with no dot
in between).
Optionally, use different delay for each strike.
AC-like (less quiet strike, less current, better
feedback) or DC (quiet strike, or for driving
external relays).
Optionally, use different mode for each strike.
Optionally, use an external alarm for detecting
door-left-open using a delay from 1 to 255 seconds
to activate and a separate delay from 0 to 255
seconds to de-activate. The alarm starts
immediately if opening the door ‘illegally’, and
after specified On Delay for ‘legal’ openings if
door remains open after specified timeout. The
alarm stops after specified Off Delay unless there
is a valid access in between.
Enabled (for better feedback)
Disabled (for minimum noise tolerance)
The sound option is not available with LogLock
Mini.
Not available with either PCB version.
Prefer the original LogLock 2000 system, if the
PIN feature is a must.
Note: PINs are still defined in user records for
compatibility with backup files from previous
and/or future LogLock versions, but not saved.
Case-sensitive 20-char long. Separate passwords
for terminal access (LOCK) and system
configuration (PASS). Protects system from
unauthorized browsing or configuration changes.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
6
Date and time setting:
File/Settings directory:
Backup/Restore/Clone:
Search who is currently logged in:
Log listing and backup:
User listing and backup:
Zone listing and backup:
Holiday listing and backup:
Log restricted by date range:
Monitor mode:
Single entry & exit control
Separate entry & exit control
Open entry and/or exit control
Optionally, restrict on ‘boss’
CR2032/CR2025 battery-backed Real Time Clock
(RTC)
Shows total, used, and free sizes for each file,
current settings, and special conditions.
Dedicated backup command (ASCII terminal
screen capture.) Restore or clone to another
device simply by sending the ASCII backup to the
device.
Search all or restrict by [partial] name.
Show all actions or restrict by [partial] name.
Backup with terminal screen capture – for security
reasons, a captured log cannot be loaded back to
the device.
Search all or restrict by [partial] name. (Backup
via terminal screen-capture)
Show all or specific zone number
(Backup via terminal screen-capture)
Show all (Backup via terminal screen-capture)
Yes, None, FROM / TO, FROM only, TO only.
Easily grab any iButton key IDs, or see who’s
attempting access, even non-users.
Entries and exits using the same ‘door’.
Entries and exits using separate ‘doors’. This is
useful for dual lane [entry/exit] garages, or
separate turnstiles.
Useful for rush hours or special events. Manual
on/off, or automatic on/off based on zone
schedules.
Access won’t be granted to anyone if (all) the
boss(es) is (are) out. Optionally, it can allow only
certain zones to enter (e.g., cleaning lady) when
the boss(es) is (are) out.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
7
Getting Help
To get a list of the available commands, type ‘?’ or ‘HELP’ on a blank terminal line and
press [ENTER]. Press [ESC] to cancel the listing or to clear the command line, press
[CTRL-S] (i.e., while holding down [CTRL] press [S]) to temporarily pause the listing,
and [CTRL-Q] to continue a paused listing.
Note: If the system seems non-responsive to anything you type, try [ESC] followed by
preferably in that order, in case the system was either halted or in monitor
mode. Also, when sending commands automatically from any application, please make
sure to start each communication session by issuing these two characters to place the
device’s terminal in a known state, again for the same reason.
[CTRL-Q],
Commands that have no parameters (like CLS) work immediately, as described in the
general help screen.
Commands that display user information or log activity (i.e., U, L, LAST, LL, and
by a partial or full name to match only those records that have a
match in all or part of the name.
WHO) may be followed
Most commands that require parameters (except for those of the previous paragraph
needing a name and a few special ones), if typed without any, print a short help message
particular to that command.
Note: The available command set is subject to change with each new firmware revision
(without prior notice) to either improve or add functionality. Every effort is made to
keep changes backwards compatible, but in some cases this is just not feasible.
This is the main help screen:
Commands
========
AC ..................
AH ..................
ALARM ...............
ANSI ................
AU ..................
AUTO ................
AZ ..................
BACKUP ..............
C ...................
CLEAR ...............
CLEARALLFILES .......
CLEARLOG ............
CLS .................
D ...................
DC ..................
DEVICE ..............
DH ..................
DIR .................
DT ..................
DU ..................
DZ ..................
Pulsed strike
Add holiday
Set alarm times
ANSI cls
Add user
Auto-exit
Add zone
Backup config
Set clock
Clear counters
Clear ALL files
Clear log
Clear screen
Set log date range
DC strike
Show/change device name (? deletes)
Delete holiday
Show settings
Doorstrike time
Delete user
Delete zone
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
8
DZU .................
EN ..................
ENTRY ...............
EXIT ................
GR ..................
GRW .................
H ...................
HIDE ................
IN ..................
INFO ................
L ...................
LAST ................
LCD1 ................
LCD2 ................
LL ..................
LOAD ................
LOCK ................
LOGALL ..............
LOGSAME .............
LOGUNIQ .............
M ...................
MASTER-RESET ........
MU ..................
NOAUTO ..............
NOENTRY .............
NOEXIT ..............
NOHIDE ..............
NOLOGALL ............
NOPASS ..............
NOZZI ...............
NOZZR ...............
OUT .................
PACK ................
PASS ................
PBZ .................
RESET ...............
REM .................
REN .................
REX .................
S1 ..................
S2 ..................
SAVE ................
U ...................
UPGRADE .............
WHO .................
ZZI .................
ZZR .................
Z ...................
Delete zone users
English
Open Entry [zone]
Open Exit [zone]
Greek DOS
Greek Win
Show holidays
Hide IDs & names
LCD is inside
OEM info
Show [named] user log
Show last [named] user log
Uni-LCD
Bi-LCD
Show quick user log
Load config
Change lock password
Log all attempts
Log same actions
Log unique actions
Monitor [min timeout]
Reset passwords
Move user zone
No auto-exit
Closed Entry
Closed Exit
Show IDs & names
Log successful attempts
Exit current mode
Normal ZZR
Normal zone check
LCD is outside
Remove deleted
Enter config mode / change password
Set push-button zone
Restart unit
Remark [string]
Request Entry
Request Exit
Single door
Split door
Save config & passwords
Show [named] users
Firmware upgrade
Show [named] IN users
Invert ZZR
ZeroZone requirement [level]
Show [n] zones
The following commands may also display in the help screen (e.g., LogLock 3000, or
special-purpose versions).
LIMIT ............... Limit Users-In
NS .................. No sound
S ................... Sound
Quick Start: A brief description of each command (OEM defaults are shown
underlined)
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
9
AC
AH
ALARM
ANSI
AU
AUTO
AZ
BACKUP
C
CAA
CLEAR
Tells the system to use AC-like pulses for driving one or both
door strikes. The PWM ratio is 70%. If followed by AC or DC
the exit strike may differ, accordingly. The first value is for
entries, and the second for exits.
Adds a single Holiday record.
Any value from 1 to 255 enables the ALARM feature for the
specified number of seconds. Use zero to completely disable the
alarm feature. An optional second value from 0 to 255 turns off
the alarm so many seconds after the alarm condition has stopped.
An alarm condition begins either immediately upon opening a
door without using a valid key or an allowed REN/REX command
(based on current date/time, zone, and ZZR settings) or after
specified delay (in case door was left open after valid use).
Similar to CLS (see below) but changes an ANSI terminal’s color
to black on gray (some people find it easier on the eyes).
Adds a User (you must provide iButton ID, zone, and name).
Enables the auto-exit feature. Auto-exit works only for zone
entries with the AUTO option defined. If followed by a zone
number (including zero zone) the auto-exit is performed
immediately for the specified zone. This feature is not available
along with the LIMIT command.
Adds a single Zone entry.
Creates an ASCII BACKUP of all files and configuration
settings. Sending the created file to any compatible LogLock
device creates a clone. For security reasons, the log file or the
secret passwords are not backed up, so these two aspects of the
device cannot be cloned. (The CAA and TEMP commands are
backed up but their values are specific to a single device and may
not apply to another device for cloning.)
Set the Real Time Clock. Use the YYMMDDhhmmss format for
entering the clock date and time. If the clock has lost its
date/time, the status LED will blink rapidly (LogLock Mini) and
the DIR display will show [INVALID] next to the time.
Clock Accuracy Adjustment changes the accuracy of the clock.
You should not change this value from the OEM default 1000
(milliseconds per second). This command is used primarily for
OEM testing but it is made available because it can also be used
in the unlikely case that after years of operation the clock is
running way too fast or way too slow, due to crystal aging.
[Please note it is normal for any clock to run a little slow or fast
which is noticeable over a ‘long’ period of time (e.g. month).
Such tiny adjustments are not possible with the CAA command.
You may have to re-set the clock every so often to correct the
time, if extreme clock precision is required.]
CLEARs the various counters (alarm, failed password attempts,
and resets) shown in the DIR display, next to the alarm delay
settings. All counters count up to 255.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
10
CLEARLOG
CLEARALLFILES
CLS
D
DC
DEVICE
DH
DIR
DT
DU
DZ
DZU
EN
ENTRY
EXIT
GR
GRW
H
CLEARs (empties) the LOG file.
CLEARs (empties) ALL FILES (user, zone, holiday, and log).
Does not affect settings or passwords.
CLears the terminal Screen.
Clears or sets the Date range used for log filtering.
Tells the system to use DC for driving one or both door strikes.
The PWM ratio is 100%. If followed by AC or DC the exit strike
may differ, accordingly. The first value is for entries, and the
second for exits.
Shows the current string or defines a new DEVICE string (e.g.,
name or comment). Use ? as the string to remove the current
setting. The string length is limited to 60 characters. The string
displays either by using the DEVICE command without any
parameters, or as part of the INFO command. Available since
v3.31
Deletes a Holiday record.
Shows a DIRectory with the current files, sizes, and settings.
Sets the Door-strike Time in 1/10th second increments from zero
(disabled) to 25.5 seconds. If two values follow, then the entry
and exit strike durations may be set differently. The first value is
for entries, and the second for exits.
Deletes a User by ID.
Deletes a Zone (all its entries) by Zone Number.
Deletes all users assigned to a specific zone, provided as
parameter to the command. If the zone is not given, the current
PBZ zone will be assumed. Because this command is potentially
dangerous, you must answer Y(es) to the confirmation prompt to
proceed. Any other key press will cancel the command. For
protection against mistakes, this command is restricted from
removing zero zones. (Hint: You may use the actual PushButton
after setting PBZ to zero to remove all zero zones in one step, if
needed. Don’t forget to change the PBZ zone back to a non-zero
number, however.)
Sets the device to use the ENglish language.
Engages the ENTRY strike (opens the entry door) if the current
ENTRY zone is zero, or assigns the entry zone. A zone other than
zero disables the manual ENTRY command.
Engages the EXIT strike (opens the exit door) if the current EXIT
zone is zero, or assigns the exit zone. A zone other than zero
disables the manual EXIT command.
Sets the device to use the GReek language using a DOS
codepage.
Sets the device to use the GReek language using a Windows
codepage.
Shows the list of defined Holidays.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
11
Partially HIDEs the display of user IDs (and user names on the
LCD) when in normal mode. Config mode always shows
complete IDs.
IN
Uses the inside reader for the PBZ option.
LCD equipped units only: The LCD is assumed to be on the
INside; therefore, it shows actions and names for exits.
INFO
Displays the firmware version, ROM version, custom user
message (see DEVICE command), and OEM contact details (when
followed by any parameter).
L
Shows the user Log for all or specific user names.
LAST
Shows all or specific users’ LAST action(s), based on current log
status. (This is similar to the WHO command but it shows all
actions, not just the entries.) Available since v3.19
LCD1
Shows access-related LCD messages for one side only (either
entry or exit, depending on whether the unit location is Outside or
Inside).
Available since v3.44
LCD2
Shows access-related LCD messages for both sides (ignoring the
unit location setting). This is useful when the device LCD is
monitored by a guard, or the device is used only as a timeattendance clock with both readers on the same side, near the
LCD.
Available since v3.44
LIMIT
Places a LIMIT on the number of users who may be inside at any
one time by not allowing further entries when the limit is reached
and until someone exits to make room for another user. A value
of zero disables the limit feature. This command is available only
on request for special-purpose versions (e.g. special garage use).
LL
Shows Limited Log; same as L but with no username display. It
can be used for faster retrieval of longer log files, and/or better
privacy from prying eyes.
LOAD
ReLOADs configuration & passwords (canceling all unsaved
changes).
LOCK
If in terminal locked mode, it enters user mode using the LOCK
password. In user mode, it does nothing. In config mode, it
changes the LOCK password. Available since v3.23
LOGALL
Sets the logging mode to ‘Log all attempts’.
LOGSAME
Sets the logging mode to ‘Log repeated same actions’.
LOGUNIQ
Sets the logging mode to ‘Log unique actions only’.
M
Enables Monitor mode. Normal mode can only enable this mode
for up to one minute at a time. Config mode can enable the
Monitor for up to 1440 minutes (24 hours). You can exit Monitor
mode at any time by pressing [ESC].
MASTER-RESET
Resets all passwords.
WARNING: It requires a one-time access code from ASPiSYS.
MU
Move User (by ID) to another zone. A quicker way to change a
user’s zone. Available since v3.20
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd. 12
HIDE
NOAUTO
NOENTRY
NOEXIT
NOHIDE
NOLOGALL
NOPASS
NOZZI
NOZZR
NS
OUT
PACK
PASS
PBZ
RESET
REM
REN
REX
S
S1
Disables the auto-exit feature. Auto-exit works only for zone
entries with the AUTO option defined. This feature is not available
along with the LIMIT command.
Disengages the entry door-strike (closes the entry door) if the
current ENTRY zone is zero.
Disengages the exit door-strike (closes the exit door) if the
current EXIT zone is zero.
Shows the complete user IDs (and user names on the LCD) when
in normal mode. Config mode always shows complete IDs.
Sets the logging mode to ‘Log successful attempts’.
If in config mode, exits to user mode. If already in user mode, it
exits to locked terminal mode. No system changes are possible.
Cancels the ZZI sub-mode.
Sets the ZZR mode to ‘Normal zone check’.
No Sound. Turns off system sound (beeps). Possible alarm
events may still occur.
Not available with LogLock Mini.
Uses the outside reader for the PBZ option.
LCD equipped units only: The LCD is assumed to be on the
OUTside; therefore, it shows actions and names for entries.
PACKs all files by removing any deleted records.
If in terminal locked mode, it enters user mode using the LOCK
password – just like the LOCK command. If already in user mode,
it enters config mode using the PASS password. If already in
config mode, it changes the PASS password.
Define the active Push-Button Zone.
This feature is available with LogLock Mini only.
RESETs (restarts) the device, as if when powered-up. It loses
any unsaved settings.
REMark string. Useful for script files (such as backup
configuration files) for adding comments or blank lines. Does not
do anything.
Requests ENtry, the entry strike activates for the primary DT time.
Same action as pressing the REN push-button (if connected).
Requests EXit, the exit strike activates for the primary DT time (if
in S1 mode), or the secondary DT time (if in S2 mode).
Same action as pressing the REX push-button (if connected).
Turns on system Sound (beeps).
Not available with LogLock Mini.
Selects ‘Single door’ mode for entries and/or exits. The zoned
EXIT command is active even in the S1 mode. In S1 mode,
entries, exits, and the ENTRY command always activate the
primary ‘door’ strike, but a zoned EXIT command activates the
secondary ‘door’ strike. A simple (zone zero) EXIT or NOEXIT
command automatically sets the device in S2 mode to get the
expected behavior. When in S1 mode, the secondary ‘door’ strike
can be used as a timed on/off switch to drive an external relay for
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
13
S2
SAVE
TEMP
U
UPGRADE
WHO
ZZI
ZZR
Z
various functions (e.g., it can be used to automatically turn on/off
the power supply to air-conditioning or other power-hungry
equipment, or the store’s light signs during hours dictated by the
EXIT zone and current ZZR mode). Because in S1 mode the
secondary strike assumes an auxiliary function and it is no longer
used for exits, the alarm is not affected by the current state of the
secondary strike.
Selects ‘Split door’ (separate entry / exit) mode. Entries and the
ENTRY command always activate the primary ‘door’ strike, while
exits and the EXIT command always activate the secondary ‘door’
strike.
SAVEs active configuration & passwords.
Defines a signed correction offset for the internal MCU
TEMPerature measurement.
You should not change this value from the default 0 (no offset) or
you may get incorrect readings in the DIR command. This
command is for OEM use. In the LogLock Mini version, it is
normal for the temperature to reach about 65º Celsius, due to the
close proximity of the Ethernet module to the MCU. It is not a
malfunction.
Shows all or specific Users.
Initiates a firmware UPGRADE procedure. WARNING: Make
sure you have the appropriate firmware file (for your specific
model and ROM version) available before answering ‘Y’es –
case insensitive – to the confirmation prompt, or you’ll lose the
current firmware, and the device will become unusable for
access control. Press [ESC] to cancel (the system will autoreset). Detailed instructions for upgrading are provided later on.
Shows all or specific users WHO are currently inside the
controlled area, based on current log status. (This is similar to the
LAST command but it shows only entries.)
Inverts the permission of the ZZR mode.
Sets the ZZR mode to “ZeroZone Required”, or changes the “ZZR
Check Above” level to the number that follows.
Shows all Zone entries, or all entries for one specific zone.
About Zones
Access control is based primarily on two aspects: Having a valid key (the iButton ID –
token), and being allowed to enter on a given day-of-week and time zone. So, what is a
zone?
A zone is used to define days-of-week and hours with down to the minute resolution
within those days when access is allowed. Note: Zones may also be used in conjunction
with the ENTRY and EXIT commands, see appropriate section for details.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
14
As an example, employees following a typical Monday thru Friday, 9am to 5pm
schedule would be assigned to a zone where Monday, Tuesday, Wednesday, Thursday,
and Friday excluding holidays are allowed, but only from the hours between 9am and
5pm. During all other hours, or during any hours on Saturdays, Sundays, or holidays,
they are not allowed access.
The AZ (Add Zone) command is used to create a new zone entry. A single zone may
have more than one entry. This accommodates situations where a single entry isn’t
capable of defining the complete schedule for a zone. All entries of the same zone act
as a single zone; therefore, a user assigned to any one zone is affected by all its entries.
Here’s the help screen of the AZ command:
Use: AZ n SMTWTFSH hhmm hhmm [AUTO]
n=1-254
For SMTWTFSH (Sun-Sat & Holidays) a dash (-) turns the
corresponding bit off. Anything else turns it on.
Times in hhmm format, e.g., 0900 1700 for 9am-5pm
A user-defined zone may be numbered from 1 to 254. A user, however, can be assigned
to a zone numbered from 0 to 255. The two extra zones, 0 and 255, are special and
always defined by the system. Zone 0 is to be assigned to those with no access
restrictions whatsoever, while zone 255 is to be assigned to anyone whose attempts to
enter we want to monitor but whom we never want to allow entrance. For some
commands, zone 255 is used to effectively turn off the relevant feature.
Days can be defined as a series of eight ‘flags’ of either dashes (-) or any other printable
characters (except for space, dash, or special control characters) in their natural
sequence, Sun-Mon-Tue-Wed-Thu-Fri-Sat followed by the Holiday indicator. A dash
means the day (or holiday) isn’t accessible for that zone entry; any other character
makes the corresponding day accessible. The holiday bit of the flags indicates whether
or not the zone also allows access on fixed holidays. Starting with v3.32 the holiday bit
can be set by itself (i.e., without any days), in which case the particular zone entry
affects only holidays, regardless of the actual day-of-week. Fixed holidays are defined
separately (see the AH command). Currently, there is no provision for defining moving
holidays, but a workaround mentioned later on is possible.
To add the zone mentioned in the earlier example, one would give the command:
az 1 -MTWTF-- 0900 1700
(or the equivalent simpler and quicker to type az 1 -11111-- 0900 1700)
You can verify your entry by giving the command Z to display all zones. If you have
many zones defined and want to view only a specific zone number, follow Z by the
desired zone number (in this example, z 1).
The zone number in the example above is 1, so any user who must obey this zone’s
restrictions must be assigned to zone 1. A zone may have more than one entry, if
necessary. However, when deleting a zone with the DZ (Delete Zone) command, all
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd. 15
entries for that zone are deleted, i.e., the whole zone is deleted. One cannot delete only
a single entry of a zone.
Zones are independent of one another. If a zone covers certain day-of-week and time
combinations, it does not restrict another zone from covering the same days and times.
It is not required that one adds all zone entries for the same zone together. One can add
one entry for zone 1, then add an entry for zone 2, then go back (days or months later) to
adding one more entry for zone 1, and so on, as the circumstances dictate.
Let’s take the example of a typical Greek retail store with morning and evening hours,
as well as Saturday mornings. The following defines a schedule for Monday thru Friday
from 9:00am to 2:00pm, Tuesdays, Thursdays, and Fridays from 5:30pm to 8:00pm in
addition to morning hours, Saturdays from 10:00am to 3:00pm, and never on holidays,
all time boundaries inclusive (e.g., the end time of 1400 blocks access when time
changes to 14:01:00, use 1359 if you want access to terminate at exactly 14:00:00).
az 2 -MTWTF-- 0900 1400
az 2 --T-TF-- 1730 2000
az 2 ------S- 1000 1500
A person with access in zone 2 (above) may enter in any of these days and within those
hours. S/he can exit anytime (see note in box below).
If multiple entries in a zone give opposing or overlapping rights, the effective
combination of these zone entries is applied during the authentication check. So, for
example:
az 3 -MTWTF-- 0800 1400
az 3 -MTWTF-- 1000 2000
allows entry on weekdays from 8:00am to 8:00pm (inclusive), which is the effective
schedule of the two zone 3 entries combined.
IMPORTANT: A zone has effect only for the entry of a person, not the exit. In other
words, if a person enters on time based on their assigned zone, they will be able to exit
any time or date afterwards, preventing a potential ‘locked in’ situation. This means
that the actual zone can be limited to the expected entry times only, rather than the
whole day schedule. So, for a 9am to 5pm scenario instead of defining 0900 1700 (as
indicated in the earlier example), one could define 0850 1100 to allow people arriving a
little early to enter rather than wait outside, but not allow anyone over two hours late to
enter, provided this is the assumed company policy. This works well only if employees
are expected to stay in throughout their work hours. If they may go out for lunch (for
example) one must allow for those times also.
To assign a zone that spans midnight, one MUST break it up into two pieces, the first
until 23:59 and the second from 00:00 to the end time, or it will not work as one might
think, e.g.,
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
16
az 4 –M-W-F-- 2100 2359
az 4 –-T-T-S- 0000 0100
lets those in zone 4 enter on Monday-Wednesday-Friday’s from 9:00pm to 1:00am,
which is always on the following day, as also shown in the definition. This, on the other
hand, will not work: az 4 –M-W-F-- 2100 0100 because not only does it ignore
Tue/Thu/Sat’s but also because it is saved as az 4 –M-W-F-- 0100 2100 with the time
automatically swapped if needed so that the starting/earlier time is always before the
ending/later time.
One can also define a schedule just for holidays. For example, a telephone operator’s
allowed shift may be defined as follows:
az 5 SMTWTFS- 0800 2200
az 5 -------H 1000 1600
This allows entry anytime between 8:00am and 10:00pm on all non-holiday days, and
only between 10:00am and 4:00pm on holidays regardless of day-of-week. A zone with
only the holiday bit was not possible in earlier versions. The addition of this new option
is fully backwards compatible, and does not alter the behavior of zones defined as in
earlier versions.
One can define auto-exit zone entries. For this feature to work, the system must be in
AUTO mode (see DIR screen and commands AUTO and NOAUTO, the OEM default is
NOAUTO, which is compatible with previous versions). Only zoned people may have
auto-exits. ZeroZone people cannot be auto-exited because they do not belong to any
user-defined zone. If the AUTO command is followed by a zone number (including zero
zone) the auto-exit is performed immediately for the specified zone. Auto-exits do not
strike the ‘door’, they only record a hypothetical exit (marked as AEXIT) based on
schedule.
As an example for this feature, one may want to automatically exit people who have a
tendency to not register when they leave. The system will auto-exit anyone whose zone
entry is followed by the keyword AUTO at the last minute of that specific zone entry. For
example,
az 6 -MTWTF-- 0900 1700 AUTO
will auto-exit any person belonging to zone 6 at 5:00pm on weekdays.
If a person strikes a true exit after the auto exit, this action will be registered, separately.
If a person strikes a true exit before the auto exit (and, therefore, that person is no
longer inside), no auto exit will occur for that person.
A zone can have some entries with and some entries without the AUTO option to get the
specific effect one needs. For example,
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
17
az
az
az
az
7
7
7
7
–M-W-----T-TF---T-TF-------S-
0900
0900
1730
1000
1400 AUTO
1400
2000 AUTO
1500 AUTO
This is similar to example zone 2 (defined earlier), but it will auto-exit people at the end
of their workday. Note that for Tue-Thu-Fri’s where there are morning and evening
hours, the auto-exit in this example occurs only at the end of the evening hours.
One may cause specific auto exit times within longer schedules by adding only the auto
exit times as separate entries. For example,
az 8 -MTWTF-- 0900 2100 AUTO
az 8 -MTWTF-- 1300 1300 AUTO
az 8 -MTWTF-- 1700 1700 AUTO
The above enables people to enter on weekdays from 9:00am to 9:00pm, and it autoexits people at 1:00pm, 5:00pm, and 9:00pm. People who enter at the exact moment
time changes to 1:00pm, 5:00pm, or 9:00pm may be immediately auto-exited by the
system. The times for auto-exit should be realistic for each zone. So, if some people
arrive at or about the time of the auto-exit, they should be assigned to a different zone
with different or no auto-exit times.
Automatic exits are shown in the log as AEXIT rather than EXIT. Please note that
attempted (but unauthorized) ‘doorman’ exits also show AEXIT.
Note: The zone-based auto-exit check is made once a minute at the beginning of the
minute. It is possible but very unlikely that if a person enters on the last minute of an
AUTO zone entry, the system will immediately log them off. In nearly all cases, the
person entering on the last minute of an AUTO zone entry will remain inside until a true
exit or until the next AUTO zone match, whichever comes first. A manual auto-exit on
the other hand, is performed immediately.
To disable the auto-exit feature without redefining any of the AUTO zone entries, give
[and optionally SAVE] the NOAUTO command. The manual auto-exit (giving AUTO
followed by a specific zone number) is always available, even when the auto-exit feature
is disabled.
Now, to what zone do you assign yourself (i.e., the boss, or security manager)? Most
likely, you and a select few others with equal authority within the company,
organization, or even your home want unlimited access. Although one could define a
zone with all days (including holidays) and hours enabled, and then assign himself to
that zone, there is a better way. Assign yourself to the pseudo-zone 0 which can never
be redefined, or deleted. A zero zone allows one to enter without any zone restrictions,
whatsoever, even if no zones are defined at all. Zero-zone users are the only people
guaranteed to enter even if the clock is wrong due, perhaps, to a restart following a
power failure combined with a dead clock backup battery, or if the ZZR mode is active.
This also saves a regular zone number (1-254) for other uses.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
18
Note: If a ZeroZone person is restricted by the optional StartDate/EndDate, access is
not guaranteed when the clock is lost.
Now, what good is the other special pseudo-zone 255? Well, that’s for users one wants
to keep registered in the system, but never give access to. “Why would anyone want to
do that?” you may ask. Because one may want to be able to only track those people’s
attempts to enter but never really let them in. The system can track (log) unsuccessful
attempts – with the command setting of LOGALL – for registered users only, not any
random iButton ID someone may use. So, if one has a person with authorization for
only one section of a building but not another, one can check if that person ever attempts
to gain access to the non-authorized area. Another reason for using zone 255 is for
keeping deleted or possible future users. One can not search the log for deleted users so,
if there is enough spare user file space, changing users from any zone to zone 255 (with
the MU command6) effectively deletes them for entry authorization but since these users
are still in the system their log shows correctly, instead of *** RECORD DELETED ***.
A description of the commands ZZR (Zero Zone Required) and its complement, NOZZR
(OEM default), follows.
With the ZZR command, one tells the system to allow people already restricted by zones
1 to 254 to enter based on their defined day-and-time schedules as usual, but considering
the additional restriction that at least one zero-zone person is already in. This restriction
also applies to the zoned ENTRY and EXIT commands. With this feature, the system
administrator has the flexibility to let people in, or engage the automatic ‘entry’ and/or
‘exit’, only when at least one of the trusted zero-zone people is already in. Since zerozone people are normally the owner, the security managers, or other fully trusted
people, when none of these people are inside the controlled area, all others will have to
remain outside, even if their zones would otherwise let them in. For example, a
storeowner may not want his employees entering the store if he himself hasn’t arrived
yet. The employees can still attempt access simply for recording show-up time for
payroll purposes (must be in LOGALL mode to record the attempt). The same reasoning
applies to auto ENTRY and EXIT in ZZR mode, i.e., only if at least one of the zero-zone
‘managers’ is already logged-in, the ‘garage barriers’ will be automatically activated
based on their defined schedule(s).
But what if one wants to keep everyone out when zero zone people aren’t in yet, except
for a select few non-zero-zone people? The cleaning lady, for example, one may want
to allow entrance even when the boss is out; they usually do their job better prior to
anyone coming in to work, or after everyone has left. But, we still do not want to make
her zero zone because:
1. We want to assign her a day-of-week/time schedule and zero zones don’t have
any, and most importantly because…
2. If we were to make her zero-zone when in ZZR mode, her entry would
automatically enable all others to enter, too as if the boss just walked in. We
6
MU is available since v3.20. For previous versions, you need two commands (DU followed by AU) to change a user’s zone.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
19
only want to exempt her from the ZZR requirement, without any undesired side
effects.
Fortunately, there is a way to do this. The ZZR Check Above level defines the zone level
above which ZZR checks are performed. The OEM default value is 0, which means
anyone assigned to a non-zero zone is subject to ZZR checking. If we set the ZZR
Check Above level to, say, 1 (with the command ZZR 1) then only people assigned to
zones above 1 (exclusive) will be subject to ZZR checking. Now, assigning the cleaning
lady to zone 1 will make her zone restricted but not ZZR restricted.
WARNING: When the ZZR mode is enabled, non-zero zone checks above the ZZR
Level may take significantly longer to complete; the actual time depends on the total
number of zero-zone users, and the current size of the log file. The delay ranges from
being unnoticeable to a minute or so for an almost full-system with hundreds of zerozone people.
Therefore, to help minimize these possible delays when using the ZZR feature, try to
restrict the number of zero-zone people to the absolute minimum needed, even if you
don’t intend on using the ZZR mode all the time. For those who are free from specific
schedules but still may be subject to a possible future ZZR mode, create a zone where
all days and times are enabled (e.g., AZ 1 SMTWTFSH 0000 2359) just like with zerozone, and assign them to that zone instead of zone zero, so their status is not checked
during ZZR mode authentication, making things faster and safer.
WARNING: When in ZZR mode, it’s crucial that ALL zero-zone people always exit
properly using their key, even if non-zero-zone people unfortunately sometimes don’t
follow the rules (e.g., they may exit by manually opening the door, or along with a
friend’s legitimate exit bypassing the system, despite your warnings against it). Having
said that, be careful whom you assign to zone zero, or they could jeopardize your whole
security scheme when in ZZR mode.
Current versions include a speed optimization related to the ZZR mode, where this extra
check occurs only under some conditions, specifically, following a reset, a zero-zone
person’s exit, or a ZZR command. As such, one should hardly ever notice any delays in
entry authorization.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
20
About Holidays
‘Holidays’ is simply a list of all dates in DDMM format of fixed (non-moving) holidays.
Year is irrelevant because normal holidays repeat each year. For example, in most
Western countries, January 1st and December 25th of every year are holidays. Each
country, or territory may have additional holidays, such as national independence days,
etc. Fixed holiday examples include USA’s July 4th and Greece’s March 25th and
October 28th, etc.
Moving holidays, such as Easter day, can be added to the list each year, e.g., around the
beginning of the year for the year ahead while removing the same holidays for the past
year. A holiday is added with the command:
AH DDMM
where DD is the date, and MM is the month. For example, AH 2512 defines Christmas day
(December 25th) as a holiday.
Some companies are closed during a fixed period each year for summer vacation. In
such cases, one would normally enter each of these dates as holidays, too. One may
also use the holiday feature to block access to most people at once (i.e., all those
lacking the holiday bit in their zones) for specific days (e.g., during office renovation
works, unplanned closings due to emergency situations, etc).
Any user assigned to a zone where the holiday bit is not set is not allowed access on
dates that are defined as holidays, regardless if the specific day happens to be in the
allowed day list.
One can delete a holiday with the DH (Delete Holiday) command followed by the date in
DDMM format as you entered it when adding the holiday. Note: No check is made if
adding the same holiday date multiple times, so other than unnecessarily filling up the
holidays file, there is no problem. When deleting, however, all same dates are removed
in a single command.
One can store up to 256 holidays, an insanely large number for holidays you may think.
This should accommodate practically anyone in any country. Because one may delete
holidays (e.g. when redefining moving holidays) one may start running out of space (as
deleting any record does not free up space). If running out of holiday space because of
deleted records, use the PACK command to remove those deleted holiday records and
make room for new ones.
About the passwords
The LogLock terminal can operate in locked [!], normal [>], or config [#] mode,
indicated by the corresponding prompt symbol inside the square brackets. The current
terminal mode does not affect the operation of the remaining system.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
21
Locked mode has no functionality at all, providing the most privacy. Use the command
LOCK to (re-) define the terminal lock password in the same way one does with the PASS
password. One must be in # mode to change any passwords.
A NOPASS command from the [>] mode goes into locked mode (indicated by the prompt
[!]). In locked mode, only the following harmless commands are available: ANSI, CLS,
DEVICE, INFO, REM, LOCK, PASS, and MASTER-RESET. [MASTER_RESET is available in all
modes in case one’s locked out by lost/forgotten password(s).] Only the INFO command
is shown in the associated help screen, however. Locked mode protects from casual
browsing of settings, or the user and log lists by chance visitors (e.g., if the unit is
accessible over the Internet).
Normal mode allows limited functionality, e.g., viewing the settings, log, and user
database. To enter normal mode from config mode, issue the NOPASS command. To
enter normal mode from locked mode, issue either the LOCK or PASS command giving
the LOCK password. To enter config mode directly from locked mode, give the PASS
password, instead. If the two passwords are the same, then the first PASS command
takes one to normal mode, and a second PASS command takes one to config mode.
To add or delete users, zones, or holidays, or to change any of the system settings or
passwords one must be in config mode. For security reasons, a user cannot add or delete
from the database lest they change their own user rights. A user cannot change the
clock, again for security reasons. Only in config mode (# prompt) one can perform any
of these actions.
As it ships, LogLock has no passwords installed, so it starts up in config mode (#
prompt) to allow initial programming. If the LogLock unit’s terminal is accessible by
anyone other than yourself, or whoever the supervisor is, locally or even over the
Internet, it is strongly recommended that you protect it by assigning the config mode a
password. It is also advised you assign a different LOCK password for even greater
security. Remember, config mode has commands that let one open the door directly
(e.g., REN and REX) without even being on location or having a valid key. For this
reason, besides assigning a password to config mode, one should always leave the
system in normal (> prompt) or even better in locked mode (! prompt), when done
viewing the log or making changes. For similar security reasons, it is also strongly
advised to assign a password to the Ethernet Module via the DS Manager.
Be sure to remember the passwords you define at all times, but never write them down
or disclose them to anyone else to prevent ‘leakage’. If you believe a password has been
compromised, you must make sure to change it as soon as possible. The command to
assign the first time password, or change it thereafter, is:
PASS <password>
for the config mode password
or
LOCK <password>
for the terminal access password
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
22
A <password> is up to 20 characters long, case sensitive, meaning that ‘My Secret
Password’ and ‘My secret password’ are two different passwords, and can include
any printable ASCII character (letters, numbers, punctuation marks, single spaces, etc.).
If you don’t want people around you to see your password as you type it, or if you want
to enter character codes not possible to type – e.g. function keys, multiple spaces, etc.,
don’t type the password on the command line. Instead, type PASS (or LOCK for the
locked mode password) and press [ENTER]. This will show:
Enter password (it will not display):
Then, you can enter the password secretly. Each typed character will be shown as an
asterisk (*) instead of the actual character you type. You can backspace to correct
mistakes, if required.
To remove a password completely, one must use the second method (secret entry) and
just press [ENTER] when asked for a password. This undefines the current password.
IMPORTANT: The password one defines or undefines will be saved during the next
SAVE command, not immediately. If you have changed your mind and don’t want to
save the changes, issue either the LOAD command (more immediate) or the RESET
command. This reloads the system ignoring any configuration changes made since the
last SAVE command. The SAVE command does not affect user, zone, or holiday changes,
which are always saved immediately.
Commands that are only accessible when a valid PASS password is entered (i.e., in
config mode) are shown in the help screen (displayed when ?[ENTER] is given at the
command prompt) only from within the # mode. To exit config mode and return to
normal mode, give the NOPASS command. To exit the normal mode, and go into locked
mode, give the NOPASS command once more.
IMPORTANT: Make sure you do NOT forget either password. If one becomes
locked out from the terminal console, the only way to reset the unit’s passwords is by
calling ASPiSYS Ltd. for instructions, and a special one-time code to remove all
passwords. Removing all power from the system and the built-in clock backup battery
for any length of time does not cause it to forget the passwords. Before contacting
ASPiSYS Ltd. for a password reset procedure, one must be connected to their LogLock
via a terminal. One may also be required to verify their identity before we give them the
one-time unlock code. One can give the INFO command for contact information.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
23
The DIR command
To check the current device status (file sizes, settings, etc.), use the DIR command. The
following is a sample display of the command. One’s actual display may be different
based on their own settings or version.
Filename Total Used+ Free
-------- ----- ----- ----Users...
448
30
418
Log..... 5733
0 5733
Zones... 1020
5 1015
Holidays
256
12
244
Clock: Mon 2009-09-07 17:00:00 DST
Lang. Code Page :
Alarm sec On/Off:
Entry/Exit delay:
Entry/Exit mode :
Unit Location
:
Separate Strikes:
Zone bindings
:
ZZR Mode / Above:
Sound/Hide IDs :
Log Mode
:
MCU Volts & Temp:
Win Greek
15/5 sec, Alarms=0, PASS attempts=0, Resets=0
1.5/1.0 sec
AC (noisy, less current)/DC (quiet, more current)
Outside
Yes
ENTRY=2, EXIT=1, PUSH-BUTTON=255 (Off)
On [BLOCKED]/1
On/On
All unique auto-exit
2.94V [25C | 77F]
From Date YYMMDD: Fri 2000-01-01 00:00
To Date
YYMMDD: Thu 2099-12-31 23:59
The DEVICE command
One may give their device a name or description. This is particularly useful if one has
multiple units installed, and wants to quickly check which unit one’s connected to.
Use the DEVICE command alone to display the current setting (if any). Follow the
command with a string parameter to change the current setting to a new value. The
string may be up to 60 characters long. Longer strings are accepted but truncated to the
first 60 characters. This feature can be used to either assign a unique name to this
device (within one’s organization), or simply to describe its location, ownership, or
person in charge, etc.
Example strings are:
College, Math Dept.
My Company
Tom’s House
Changing the name/description string is only possible in # mode. To remove the string
completely, give just the character ?. Viewing the device name/description can be done
in any mode. If a device string is defined it is included in a BACKUP command. The
string is raw, and it is not affected by the current language setting (as with user names).
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
24
Adding / deleting users
Before gaining access, a user must be entered into the LogLock’s database. This is done
via the AU (Add User) command, whose format is shown below as when one issues the
command without any parameters:
Use: AU ID(16) PIN(4) ZONE(3) [FROMDATE(6) [TODATE(6)]] "username(20)"
Dates in YYMMDD format, e.g. 090117 = Jan 17, 2009
Username: Lower=Greek, Upper=English
ZONE 1-254, (0=Always, 255=Never)
PIN="NONE"
The numbers in brackets indicate the expected, or maximum length for that element of
the command. The username length may be different from the one displayed above
depending on the specific version one owns. Square brackets embrace optional portions
of the command.
DOS Greek (GR), Windows Greek (GRW) character codes or lower case English
characters in the user name field are interpreted as Greek when in Greek modes, while
uppercase are always interpreted as English (Latin alphabet). When in English mode
(EN), one may use both upper- or lower-case names, but searching for them (U, L, LL,
and WHO commands) is case-sensitive, so one must remember to type them the same way
one entered them with the AU command.
The iButton ID is the unique code of the user’s iButton key. Usually, it can be found
engraved on the iButton key itself but one doesn’t need to memorize it, or write it down.
You can use the Monitor mode to quickly have the iButton number display on the
terminal each time you touch it on either reader, regardless if it is already registered in
the device. Alternatively (for units equipped with an LCD), one may hold it firmly on
either key reader of the unit (depending on the Unit Location setting) for about 2
seconds until the key code displays on the LCD. The code will keep displaying until
one removes the iButton from the reader. This code is always exactly 16 characters
long, comprised of hexadecimal digits (numbers from 0 thru 9, and letters from A thru
F).
The iButton ID contains a checksum that indicates whether the number is correct or not.
If any digit is wrong while typing the ID, the checksum fails and the command issues
the message parameter error(s).
Special ‘doorman’ ID
There is one special ID one can use that does not correspond to any real iButton key.
This ID is made of all zeros (‘0000000000000000’) and it is an always defined system
ID that is assigned to the hypothetical ‘doorman’ which is whoever presses the REN / REX
buttons. An actual doorman may have his/her own real key, regardless.
Although the zero ID is always defined internally in the system, one may also define it
in the actual user file.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
25
If the zero ID is not defined in the user file, then the REN and REX commands and their
associated push-buttons (if connected) work at all times without any restrictions. The
log listing shows all Request-To-Enter and Request-To-Exit actions with a
corresponding system name without any quotes, which isn’t searchable because it does
not really exist in any file.
On the other hand, when the zero ID is actually defined in the user file with the AU
command, it is necessarily assigned to some zone, and then it behaves like a regular user
key, except it is not actually possible to read it from the iButton readers. In that case,
the REN and REX commands obey the restrictions of the zero ID’s assigned zone. As is
the normal behavior, a zero zone always allows use of these commands; zone 255 never
allows use of these commands (effectively disabling the commands and their associated
push-buttons), while all other zones behave according to their definition. So, this
feature allows one to have REN and REX commands and push-buttons that are only
functional for specific days and times. The name given to the zero ID user is displayed
in the log listing instead of the generic system name. This name is now searchable just
like any other user name.
The system must be in LOGALL mode for zero ID events to be recorded.
PINS ARE NOT SUPPORTED; THE FOLLOWING PARAGRAPH IS FOR
COMPATIBILITY WITH PREVIOUS VERSIONS ONLY.
A PIN is made of exactly four decimal digits (0 thru 9). The special PIN codeword NONE
(case-insensitive) is special in that the user is not required to enter a PIN regardless of
the status of the PIN mode. Numeric PINs, on the other hand, are required verification
when the system is set in PIN mode (do a DIR command to see current settings and
modes).
A zone number is a decimal number of up to three digits. The number must be in the
range 0 thru 255, or else an error message is displayed. Remember that zones 0 and 255
are special and do not correspond to any user-defined zones. In short, zone 0 allows
access at all times while zone 255 disallows all entry and exit accesses but keeps track
of any such attempts in the log file (if in the LOGALL mode).
An optional StartDate and EndDate may be entered in YYMMDD format. To enter an
EndDate one must also first enter a StartDate, although a StartDate does not
necessarily require an EndDate to follow it. A StartDate enables the specified user’s
access rights on that date. An EndDate, if defined, disables the specified user’s access
rights at the end of that day. No access is allowed at all outside the provided date range.
This feature is useful for temporary users with a starting and/or expiration date. To
define just an expiration date, one is required to also provide a starting date, so just use
any past date or today for starting date to be allowed to enter an expiration date.
The StartDate and/or EndDate may contain ‘wildcards’. This feature is 100%
backwards compatible. Wildcards are entered as two dots (..) in place of the YY, MM, or
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
26
element of the StartDate or EndDate for the AU command. Wildcards effectively
skip the check for that part of the date against the actual clock. Therefore, a wider
selection of date ranges becomes possible. Examples using the wildcard dates are
shown below:
DD
AU FF00123456789A01 NONE 200 ....01 ....07 “Paper Supplier”
AZ 200 -M------ 0900 1300 AUTO
The above user is restricted to enter on dates between 1st and 7th of every month of every
year. Because the user is further restricted by zone 200, which allows entry only on
Mondays from 9:00am to 1:00pm, the user is able to enter only between those hours on
the first Monday of every month of every year. Instead of 01 to 07 which is for the 1st
week, use a DD 08 to 14 for 2nd week, 15 to 21 for 3rd week, 22 to 28 for 4th week, and
possibly 25 to 31 for last week.
Another example: A seasonal worker in a hotel is needed for the months of May to
September every year.
AU FF00123456789B01 NONE 201 ..05.. ..09.. “Pool cleaner”
AZ 201 –M-W-FSH 0700 1100 AUTO
A final example: A person is allowed only around Christmas day every year.
AU FF00123456789C01 NONE 202 ..1222 ..1228 “Santa Claus”
AZ 202 SMTWTFSH 2200 2359
AZ 202 SMTWTFSH 0000 0400 AUTO
With the current implementation, YY wildcard date ranges that span year changes (e.g.,
from December to January), or MM wildcard date ranges that span month changes (e.g.,
from 25th to 5th of next month) are not possible.
Finally, the user name is entered within double quotes (“user name”). Only the first 20
characters are significant (Note: the number of significant characters may be different
based on the particular version one owns). A null/empty name – two double quotes with
nothing in between –adds and deletes the user immediately, so it is practically useless,
except for testing purposes, e.g., to see the effects of a PACK command. To add an ID
without any name use at least one space inside the double quotes for the name or a
special codeword that you prefer, such as “PRIVATE”.
One cannot add another user with the same iButton ID because each iButton is supposed
to be given to exactly ONE user. No sharing of iButton IDs is allowed. The iButton ID
can be considered the unique index of the ‘user table’ of the database. It is also strongly
advised to not give a single person more than one iButton ID key. Since the same ID
can be used with multiple units, there is absolutely no reason at all for people to use
more than one key each, regardless of the number of access points.
Different users may share the same user name, however. The unique part of a user is the
iButton ID, and only that. Nonetheless, it is recommended that users with the exact
same name, be given slightly different names (an extra dot, or first-last and last-first
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd. 27
versions of the same name, for example) to make it easier to differentiate the two in user
or log listings without having to look at, or remember their iButton IDs. So, for
example, if two people are named ‘John Doe’, one could be entered as “John Doe” and
the other as “Doe, John”.
Since there is no ‘change user’ command, to change a user’s database record (for
example, to change a user’s name), one must first delete it if one plans on using the
same iButton ID, and then add it again using the new or modified information. To
delete a user, use the DU (Delete User) command followed by the unique iButton ID for
the user one wants to delete. Hint: Use the U command followed by a name to locate the
user, double-click on the ID to mark it, and then copy it (using [CTRL-C] in most
terminal programs.) Next, give the DU command followed by a space and the pasted
back ID ([CTRL-V] in most programs).
LogLock Mini only
One can also quickly add or delete ‘temporary’ users by means of the small push-button
opposite the clock battery holder.
Users added with the push-button are given the ‘mystic’ name “?” and assigned to the
zone currently defined via the PBZ command (see DIR display). The optional start/end
date will not be defined when PBZ is set to zero. For non-zero PBZ, the start date will
be set to the current system clock date. This allows you to know when the ‘temporary’
user was added. If one makes the PBZ command point to zone 255 (OEM default)
which never allows entry, the push-button feature is completely disabled either for
adding or deleting; no, it does not add users to zone 255.
To use this feature for adding a user, first briefly touch the key you want to add on the
outside/primary reader (when Unit Location is ‘Outside’), or the inside/secondary
reader (when Unit Location is ‘Inside’). After removing the key from the reader, press
the small push-button for at least one (1) second but no more than four (4) seconds.
This will add the specific iButton key and give it the username “?”. If the key already
exists, it is not added a second time, nor moved to the PBZ zone.
To delete all users assigned to the current PBZ zone, press the small push-button and
keep it pressed for at least five (5) seconds. Users assigned to all other zones will not
be affected at all.
This feature is useful for quickly adding or deleting temporary users, without using any
PC connection and without affecting any of the permanent users. The rights these users
have are the current rights of whatever PBZ zone was active at the time the user was
added. In other words, the zone that was assigned to a user at the time the button was
pressed remains constant even if the PBZ zone is later changed to another.
About the Log
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
28
The log keeps track of all user entries and exits. The log keeps the exact date and time
of each successful or attempted entry or exit. By default, unsuccessful attempts (e.g.,
attempting to enter outside the user’s zone limits) are not recorded to save log space for
successful attempts. If you need to record both successful and unsuccessful attempts
from registered users (e.g., those attempting to enter outside their zone restrictions), use
the LOGALL command to set the system in ‘log all attempts’ mode.
If you want to revert to keeping a log only for successful attempts, use the NOLOGALL
command.
One can also save significant log space by using the LOGUNIQ command. The OEM
default (LOGSAME command) records all actions even when the same action is quickly
repeated many times within the same clock minute for some cases indicating a possible
pass back attempt. Normally, a user may attempt multiple successive entries because
s/he does not realize s/he attempting entry outside the user zone’s allowed day-ofweek/time combinations, and falsely assumes there is some misread of the iButton ID
key, or some other temporary problem, that won’t allow access. S/he will eventually
give up, after having filled the log with a bunch of unsuccessful attempts in LOGALL
mode. In the OEM default mode, every single attempt is recorded and in situations as
the one described, there could be tens of them. With the LOGUNIQ command, however,
only different actions are logged. It is sufficient for the clock minute alone to advance
for the action to be considered different. So, one won’t see more than at most a single
attempt for each minute of the hour unless another user enters or exits in between.
If you need to record unsuccessful attempts from non-registered iButton IDs, use a
terminal program with a screen capture capability, and leave LogLock into Monitor
mode (M command) during times you want to collect this information. This will record
all attempts to enter or exit, even for iButton IDs that aren’t part of the system. The ID
along with the words ENTER, EXIT, or ----- is displayed, depending on whether the
attempt was an entry, exit, or unsuccessful entry, respectively.
IMPORTANT NOTE: If one leaves the unit in Monitor mode and the network
connection is either intentionally terminated or lost, or if while in Monitor mode
you pause [CTRL-S] the terminal output, the unit may stop responding to further
iButton keys (for up to 10 seconds, until the system auto-detects this situation and
unblocks the blocked reader).
This is because in Monitor mode, the device must first output the collected
information from the last key read before accepting another key, and if the
connection is either closed/lost or paused that output is suspended until the
connection is re-established or the listing is continued [CTRL-Q].
It is best if one does not leave the unit in Monitor mode, when unattended. However,
as a safeguard against being left in Monitor mode by oversight (or malice), please
note there is a maximum time limit of up to one day (1440 minutes) for the M
command, available only from the config mode, while the default value if no time is
specified, or if issued from normal (non-config) mode is only 1 minute.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
29
The log for a specific user can be displayed using the L and LL commands followed by a
[partial] user name, but without the quotes used when creating a user. This is useful for
viewing a specific user’s ‘in’ times for a given period, say, a month. Alternatively,
using a terminal’s screen capture feature, one can download the complete or within a
date range log to their computer for automatic time calculations on the PC. Additional
software is needed for this task. We may be able to supply you with such software for
PC based computers on an as-needed basis at extra cost. If there is a programmer inhouse, they can easily write a small program to extract this information from the
captured log file, and calculate total times as required by one’s organization. We can
provide pre-written scripts to setup a database (such as MySQL or SQLite), and keep it
updated by ‘manually’ or ‘as scheduled task’ running a couple of scripts, or so. Then,
one can get summarized information for each and every user, one at a time or all
together.
Except for not displaying the username, the LL command is identical to the L command.
This results in faster overall downloads of large log files.
Although the log space is rather large (5733 records in the OEM default version),
eventually it will become full (but not stop logging newer actions). If you’re interested
in keeping accurate log history for periods longer than can fit inside the device’s internal
memory, it is expected you retrieve the log well before it becomes full (e.g., at the end
of year, end of month, end of week, end of day, etc. depending on usage – number of
users, and number of entries/exits per user per day on average), and then optionally
clear the log completely with the CLEARLOG command.
Hint: To avoid the possibility of losing any actions during the short interval between
the completion of the log transfer and the issuing of the CLEARLOG command, one can
opt to not ever clear the log manually; rather, let it auto-truncate the oldest 39 actions
when full, and use the Date Range (D command, see below) to retrieve only newer log
entries. If you retrieve the new log from a specific date and time combination you will
get only a minimum amount of overlaps with existing log entries from the previous log
retrieval (in case you’re pulling the log more than once per given period), or no
overlaps if retrieving between fixed past periods (e.g., every day for the previous day up
to 23:59 – last minute of day).
Note: A database (such as MySQL or SQLite) can be indexed such that it will not allow
duplicate entries in its tables. (An index based on the iButton ID, date, time, and
direction is sufficiently unique. A pre-configured MySQL database script may be
available on demand.)
On attempting to log an action when the log is full, the device automatically first erases
a log page (i.e., 39 records) of the oldest log information to make room for the newer
information. So, at any given time unless one specifically clears the log with the
CLEARLOG command, the log holds at least the 5695 (depending on version) most recent
user entries and/or exits.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
30
To define a date range for the L (Log) or LL commands, use the D (Date range set)
command. Pressing D[ENTER] shows this:
No Date Range, use: D YYMMDD[hhmm] [YYMMDD[hhmm]] (*=today)
and cancel any previous date range setting. To set the date range from Aug. 13 to Aug.
29, 2004 (Athens 2004 Olympic Games), use this command:
D 040813 040829
When [ENTER] is pressed, the system responds with:
From Date YYMMDD: Fri 2004-08-13 00:00
To Date
YYMMDD: Sun 2004-08-29 23:59
Dates are entered in YYMMDD format and must be exactly 6 digits long, or entered in
YYMMDDhhmm format and be exactly 10 digits long. If choosing the YYMMDD format, then
the time is automatically set to the beginning of the day for the FROM date and to the end
of the day for the TO date. The first date is the FROM date while the second date is the TO
date. Then, the log displayed with the L or LL commands is limited to accesses during
this period (inclusive). One can also use the command with only a FROM, or only a TO
date.
To set only a FROM date (to see log entries FROM that date onward), give only the first
parameter to the command. For example,
D 040813
limits log viewing from Aug. 13, 2004 and later (to any date). After pressing [ENTER]
the system responds with:
From Date YYMMDD: Fri 2004-08-13 00:00
To Date
YYMMDD: Thu 2099-12-31 23:59
(Notice how the TO date is automatically set to the latest date and time possible, i.e.,
Dec. 31, 2099 11:59pm)
To set only the TO date (to see log entries from any date TO a specific date), give any
invalid date for the FROM date followed by a valid TO date. For example,
D x 0408291700
limits log viewing from any date to Aug. 29, 2004 at 5pm (inclusive). The ‘x’ acts as a
‘don’t care’ indicator. Any date that isn’t made up of valid numbers and/or doesn’t
contain exactly 6 or 10 digits is invalid and, therefore, considered a ‘don’t care’ date.
After pressing [ENTER] the system responds with:
From Date YYMMDD: Sat 2000-01-01 00:00
To Date
YYMMDD: Sun 2004-08-29 17:00
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
31
(Notice how the FROM date in this case is automatically set to the earliest date and time
possible, i.e., Jan. 1, 2000 12:00am)
To quickly set either date to today (based on the current clock setting), use a single *
character for date (From and/or To), e.g.
D *
D * *
NOTE: The system only understands dates for the years 2000 to 2099. Since the first
date is already past while the second one is beyond the expected life of this device, it is
a non-issue for actual use. Anywhere one is expected to enter a year, one must omit the
leading 20 because the system expects all dates to be in the above range.
One can see the currently effective date range by issuing the DIR command. The date
range remains in effect until one changes it or the system is reset.
Any log viewing commands are always restricted to within the effective date range.
Even if one searches for a user name in the log (with the command ‘L username’ or
‘LL username’), only those accesses that fall within the effective date range are shown.
Since the date range auto-calculates and displays the day-of-week for the given date(s),
one could use this function to check on what day-of-week a specific date falls.
IMPORTANT: Don’t forget to reset the date range before taking a complete log
backup or set the date range for an incremental log backup (e.g., to use with a PC
application). Press D[ENTER] to reset the date range to the default values of
2000/01/01 00:00 to 2099/12/31 23:59. Then, press L or LL[ENTER] to get the
complete log.
Finding out who’s ‘in’
LogLock gives one the ability to know who’s supposedly ‘in’ by checking the log for
those who have registered an entry without a following exit. For accurate results, it is
assumed that users have entered within the same log period (i.e., within the last 5695
transactions – actual number depends on version). Otherwise, there is a possibility the
log gets truncated to make room for newer entries, losing the information for the oldest
entries. Under normal usage, this is highly unlikely to occur as even with a totally full
user database (448 people for the default version), each and every user has to go in or
out over 12 times on the same day for the log to become full and risk losing older
entries.
The who command examines each user’s log activity. Any user who has entered but not
yet exited is considered to be ‘in’. Obviously, this will not be correct if people are
allowed to exit bypassing LogLock (e.g., by manually opening a door, or exiting along
with another person’s legitimate exit, without using their own key).
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
32
Just like the U, L, LAST, and LL commands, the WHO command may be followed by a
partial user name to limit the search to only those users whose name includes the one
given.
Similarly to WHO, the LAST command allows to view the last (most recent) action of any
user. Again, only actions currently in the log are considered. This command helps to
quickly find when was the last time someone accessed the system for either entry or
exit.
Setting the clock
To set the real-time clock of the device one must use the C (Clock) command. The C
command expects the date and time in the YYMMDDhhmmss format (note that seconds
must be given also – if one doesn’t care for such accuracy the value 30 for seconds is the
best guess). For security reasons, only in config mode (# prompt) one can change the
date and time.
As an example, to set the date and time to ‘5:30:45pm August 15, 2004’, give the
command:
C 040815173045[ENTER]
One will not be allowed to enter incorrect date/time codes. The day of week does NOT
need to be entered, as the unit is capable of automatically calculating it from the date.
Daylight Saving Time (DST) is automatically detected based on EU’s rules for changes
of time twice a year (last Sunday in October from DST to Normal, and last Sunday in
March from Normal to DST, at 3:00am). When setting the time the unit automatically
goes into DST or normal mode depending on the date entered (on a switch date itself,
the new mode is set, regardless of time). Thereafter, the clock keeps track of the correct
time even during time changes from Normal to DST or back. This makes it very
convenient for the day(s) after a time change when people show up to enter based on the
changed time.
The clock is protected from power failures via a small long-life lithium battery (type
CR2032 or CR2025) that keeps the clock running for several days of continuous power
loss. If, however, the unit is left unpowered for longer periods of time, the clock battery
will eventually run out and will then require replacement. The device is not serviceable
by the casual user.
Please note that even with a totally drained clock battery, the unit is still usable but
unless its power-supply is protected by a UPS (Uninterruptible Power Supply) system, it
loses its date and time information every time there is a blackout (or even a brownout
on occasion), and it must have its clock manually reset to exit the startup error
condition (see box below).
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
33
IMPORTANT: When losing the date/time due to a clock battery failure, the unit
reverts to midnight of January 1st of the firmware’s Build year, certainly a past date, and
the status LED (for LogLock Mini) will blink rapidly – normally, the LED blinks every 3
seconds. The DIR display will show the message [INVALID] next to the time. In this
error condition, only zero zone people (including REN/REX events) are allowed access,
since date/time cannot be trusted for zoned access. Any actions (which in this error
condition can only be accepted from ‘ZeroZones’) are not logged because the date/time
is known to be invalid, and logging such actions/attempts would disrupt the normal
chronological sequence in the log file. Setting the clock with any date/time (past 2008)
clears the error condition, and normal operation resumes.
Changing the LCD and username-in-listings language
LogLock is partly bilingual. For units equipped with an LCD, it shows messages on the
LCD in either English or Greek. Other languages may be added (instead of Greek) in
the future, if sufficient demand warrants it. Also, the user names are shown on the
connected terminal in the selected language.
The device’s terminal interface is always in the English language. This is because
Greek or other non-Latin-alphabet languages don’t use a standard character-display
coding scheme among different computers (e.g., PCs, Macs, UNIX, etc.) or different
countries, and the Greek or other language fonts aren’t default in most systems that
support these languages. This would make it very difficult to use the device if the
language was set to Greek and the connected terminal didn’t show it correctly.
The LCD display the user sees can be switched from English to Greek, or back. To
switch to English, give the EN command. To switch to Greek for DOS, give the GR
command. To switch to Greek for Windows, give the GRW command. GR and GRW are
only different at the terminal display, not the LCD.
The current language setting can be seen from the DIR command display, and it controls
all messages on the LCD, including the date and time, except for the user names.
User names on the LCD are always displayed in uppercase when Greek is selected, and
mixed case when English is selected. On the terminal, however:
If the language is English, user names are displayed exactly as entered with the
AU command.
If the language is Greek (for DOS), user names are displayed in uppercase Greek
for DOS code page for Greek and uppercase English for English names. Greek
for Windows works like Greek for DOS except the terminal code page is
different.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
34
Packing or ‘Garbage Collection’ (Technical Note – not needed for operation)
The non-volatile memory used by LogLock for keeping settings, zone, holiday, user, and
log information is writable in a special way that does not allow erasing small amounts of
information at a time. Erasures must be done in sizeable chunks. Also, this memory is
guaranteed by its manufacturer to at least 100.000 write-erase cycles which is truly a lot
but not infinite. In practice, this translates to well over 550 million accesses, which
even with the heaviest possible business usage imaginable (one access per user, per 10minute period, per 24-hour work day), it is over four decades! It is theoretically
possible, however, that the memory will eventually go bad for writing data to it, and it
will need replacement. Special programming techniques have been utilized to extend
this writing period for as long as possible, so that you can enjoy many years of servicefree operation. For most installations, this limitation is a non-issue.
When deleting users, zones, or holidays, the unit doesn’t actually delete these; it simply
marks them for deletion (yet, this is an action that cannot be revoked). This means that
the space taken by the deleted records doesn’t become available automatically. To truly
remove any deleted records from memory, one must use the PACK command. This
command skips over all records marked as deleted while copying the rest. This
procedure is called ‘garbage collection’. If running out of memory space (as reported by
the DIR command’s FREE column), one can use the PACK command to regain any
blocked unused memory. Please try not to use the PACK command casually (for
example, each time one deletes a single user, zone, or holiday).
When changing passwords or options (such as the open-door strike time), the device
keeps these changes in a temporary memory rather than save them immediately. This
allows making these changes more than once for testing a behavior before committing
them to memory. To make these changes ‘permanent’ one must use the SAVE command.
Because of the write-erase cycle life of the memory, it’s recommended one use the PACK
command only when truly necessary. In other words, it’s not required to type the
command each time one deletes a single user or zone. Give the SAVE command only
when you must change any of the DIR settings or passwords, or the PACK command
when there is no space remaining in any of the files, and you need to add data to them,
or if you have a significant number of accumulated deleted records (cleaning up the files
may improve overall performance). This helps prolong your unit’s life to the maximum.
(The FROM and TO search date range are never written to this special memory, so a SAVE
or PACK command is never needed for accepting changes.)
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
35
Using LogLock for entry or exit
The system comes with two iButton ID readers, one for each side of the protected area.
The unit is always placed on the inside with one reader placed on each side of the access
point. This provides full protection from vandalism (i.e., zero hands-on access to the
system from outsiders). The commands IN and OUT tell the system whether to use the
LCD for displaying exits or entries, accordingly. The device firmware then knows how
to behave correctly for each case.
If a Request-To-Enter or a Request-To-Exit push-button is connected, pressing the
button momentarily opens the corresponding door using the defined Door Time setting.
No action is logged, unless in LOGALL mode. This push-button is normally used by
secretaries or other human operators letting visitors in or out. Visitors normally do not
have their own keys and depend on someone else to open the door for them. In a more
secured installation where all ‘visitors’ must be pre-validated, the Request-To-Enter and
Request-To-Exit buttons may have to be left unconnected to prevent the possibility of
any user entering or exiting without the use of their iButton ID (especially if the REN or
REX button is placed too close to the access point, and not controlled by a security
guard).
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
36
Dual strike mode
LogLock can be set to use separate strikes for entry and exit. This is useful for
situations where a different path is taken for each action (e.g., garages with separate
lanes for entry and exit).
The primary strike (LOCK1 or LC1 in the connection diagram) is used for both entry and
exit, if the device is set for single strike mode (with the command S1).
When set in split (dual) strike mode (with the command S2), entries always activate the
LOCK1 strike, while exits always activate the LOCK2 or LC2 strike, regardless if the unit
is set to be inside (IN command) or outside (OUT command).
The ENTRY command can be used to open the entry door (or garage barrier) connected at
LOCK1 while the EXIT command can be used to open the exit door (or garage barrier)
connected at LOCK2, and keep it open continuously (e.g., during rush hours one may
want to raise the garage barriers for efficiency). The iButton keys can still be used to
register the requested access for time attendance purposes, but the strikes do not close
after the defined timeout (DT command). To cancel either command, use the NOENTRY
and NOEXIT commands, respectively.
If the rush hours are foreseeable and follow a specific day / time pattern, one could
define a zone for them for automatic use. A zone number may follow the commands
ENTRY and EXIT. If the zone number given is 255 (the OEM default), the commands are
disabled. If the zone number is 0 then the original behavior of indefinite engagement is
enabled. When supplying a zone number to either of these commands, the zone is set
but the command may appear to not be activated immediately (depending on the
situation, if zones are to be respected). If one gives a zone from 1 to 254, and that zone
is defined, the strike is activated on the days and times dictated by the zone, and deactivated during days and times the zone won’t allow. This is very flexible in that one
may have the strike(s) automatically engage during, say, business days and specific
‘rush hours’. Since a different zone may be used for entry and exit, you can allow for
different ‘rush hours’ for entry and exit.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
37
REN and REX commands
The REN and REX commands behave exactly as if someone presses the REN or REX
buttons connected to the corresponding connectors on the diagram. When used with
split strike mode, REX always applies to the exit strike.
Battery-Low warning
If connected appropriately, LogLock can warn you when the external supply battery
(e.g., UPS battery) is running low and needs replacement or other maintenance (e.g.,
charging). LogLock Mini shows the optional rechargeable battery’s status, instead. The
warning appears with the DIR command and, for LCD-equipped units, on the LCD in the
selected language along with the date and time displays.
LogLock Mini Only: Use of an optional 9V rechargeable battery
WARNING: First and foremost, do NOT use any type of non-rechargeable
battery, or there is risk of serious damage, battery explosion, and personal injury.
If you connect one by mistake, disconnect it right away, as the dangers we warn
about may not become apparent until some time later. When connecting the
battery please observe the polarity.
LogLock Mini is capable of temporarily operating off an optional 9V rechargeable
battery. We strongly recommend the use of 8.4V (rather than 7.xV) rated batteries from
any reliable manufacturer. The mAh rating is up to you but, obviously, the higher the
number the better the performance you get.
Do not confuse the use of this battery with the CR2032/CR2025 clock backup battery,
the two are not related. The clock battery is meant to keep just the real time clock
running when there is no other source of power, and the device is non-operational.
On the other hand, when the mains power is lost or disconnected, the optional 9V
battery kicks in and keeps the system running for doing its primary job, access control
and/or time attendance. It acts almost like a tiny UPS. The system will be able to strike
the door for several times, so you won’t get stuck outside waiting for the power to come
back on. On a full charge you will get several tens of strikes – the actual number
depends on several factors, such as the DT strike duration setting, the strike mode (AC or
DC), the strike type used, etc.
The system keeps this battery fully charged at all times when the mains power is normal.
Charging is slow and may take many hours to reach full charge. But you should not
worry about it. Under normal circumstances, the main power failures are few and far
between giving enough time to the battery to recharge and be ready for the next one.
Unlike with some general-purpose chargers, there is no risk of overcharge. The battery
remains in stand-by for when it’s needed.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
38
To save power for the primary job of the device (access control), other functions have to
be shut down when the system runs off the 9V battery. Therefore, the Ethernet module
as well as the LCD (if connected) will be powered down. When the mains power
returns to normal, the Ethernet module (and LCD) will be re-initialized. If a telnet
connection was active before the power failure, it must be re-established.
Charging is fully automatic. There are no options or settings to adjust. Whenever a
battery is installed, it is under the control of the built-in charger. You can see the DIR
display to check the battery status and charging state. If the battery fails to charge for
very long (while charging the voltage remains constant and far below normal), it may
be time to replace it with a new one.
Mass-erase actions
Some commands are meant to completely erase single files, or all files. All delete
commands (e.g., DU for delete user) can optionally be followed by the word ALL to delete
all records in that file with a single command. A verification of the action is required to
prevent mistakes. If you are certain you want to proceed with the action, enter Y (for
Yes). The command for erasing all log entries is CLEARLOG while the command for
erasing all files (including the log, but not the system settings, or passwords) in a single
step is CLEARALLFILES. All these actions can only be performed in PASS mode.
Contact information
The command INFO displays our company’s contact information (address, phone
numbers, etc.). Use it whenever you need to contact us. This information should be up
to date according to the purchase date (or latest firmware upgrade, if applicable) of your
unit. Should you require a firmware upgrade (e.g., to take advantage of added features
in later versions), please contact us. Firmware upgrades (command UPGRADE) consist of
loading an ASCII file via a telnet connection (e.g., HyperTerm – recommended because
of its ‘File Send’ capability), and unless the update is performed to fix a possible
remaining bug in the system, it may be not free (at our discretion).
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
39
Firmware Upgrade
By ‘firmware’ we refer only to the application firmware of the device, which is user
upgradeable, and which runs on top of another fixed ROM (Read Only Memory)
firmware which contains a BIOS, our OS8 real-time multitasking operating system, and
upgrade related functions.
From time to time, we may provide free firmware upgrades. We highly recommend you
update your device(s) as soon as possible to take advantage of improvements, or added
features.
The ROM portion is not upgradeable by the end user. A ROM upgrade is normally not
required, as we provide various firmware versions to match your specific ROM BIOS
version. Nevertheless, earlier ROM versions may be upgraded to the latest version at
no cost (other than possible round-trip shipping charges) by returning the unit to us.
Note1: BIOS bOS8 v1.70+ will not allow sibling product firmware use. Only a
compatible BIOS (bOS8) version and LogLock model firmware image can be used.
Note2: BIOS versions which differ only in the final digit can accept the same firmware
image as the base version. For example, for all BIOS bOS8 v1.7x devices, you must
select the BIOS v1.70 firmware version, regardless of the actual value of x in your
device.
Note3: After upgrading to a new firmware version, issue the CLEAR command to zero all
counters, as the values shown may be random.
Begin by downloading the correct firmware for your device from our website:
http://www.aspisys.com/firmware/ adding the appropriate filename as described below.
Note: All filenames are case-sensitive. Please observe the correct case when typing.
Specifically, the word BIOS is uppercase, everything else is lowercase.
To locate the correct firmware file for your device, please follow these instructions:
1. Identify the type of device you own (INFO command), e.g., LogLock 3000 or
LogLock Mini.
2. Identify the BIOS version you have (INFO command). You can also ‘guess’ the
version by looking at the Revision History, if you know the purchase date. If a
BIOS version isn’t shown, your BIOS version is v1.0
3. Download the correct firmware from http://www.aspisys.com/firmware/ by
adding the filename loglock_MODEL_firmware_NNN_[BIOSv?_?].s
replacing MODEL with your unit’s model (e.g. ‘3000’ for LogLock 3000, ‘mini’
for LogLock Mini, etc.), NNN with the 3-digit firmware version (e.g., for v3.41
NNN should be 341), and finally ?_? with the BIOS version (e.g., for BIOS
v1.4x, use 1_4). They’re no spaces in the link, only underscores. As an
example, for the 3.41 Mini version for BIOS v1.40, the correct firmware is:
http://aspisys.com/firmware/loglock_mini_firmware_341_BIOSv1_4.s
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
40
Please see the revision history section later on for details on version changes.
WARNING: Sending the wrong firmware file to your device may make it
completely inoperable as an access control system until the correct firmware file is
loaded. Some firmware versions are closely related, and although they may appear
to work even when loaded into a different system from the one for which they were
intended, correct operation should not be assumed under all situations.
Updating is both simple and fast; it normally takes less than one minute to complete. It
can be done over the network from anywhere you have allowed access to your device,
even over the Internet7, if you have set up your router to allow access to your LogLock
from the outside. Of course, you need to know the PASS password to enter # mode
before commencing.
If you happen to encounter undocumented incompatibility issues or other problems with
a newer firmware, please let us know immediately. In such cases, you may re-load an
older firmware version until a newer version is provided.
If unsure, please issue the INFO command to see the current version of your system. If
the latest version of this manual (http://www.aspisys.com/loglock_mini.pdf) refers to a
later version than the one you have, please contact us to obtain the latest firmware file.
If you have purchased the system directly from us, you may receive email notifications
for possible upgrades as they become available.
To send a firmware file to the device, follow these steps:
1. Make sure you have the required firmware file readily available before
continuing.
2. Connect to your device using HyperTerm or similar application.
3. If upgrading to the same user/log ratio version, the data files are not affected.
But to be safe against possible user errors, it’s advised to make a backup of the
device configuration, at this point. Following a firmware upgrade, all device
settings (including the passwords) are restored to their OEM default. Make a
backup with the BACKUP command, if you want to make it easier to restore the
previous settings.
4. Initiate the firmware upgrade procedure by issuing the UPGRADE command from
the # (config) mode.
5. Answer ‘Y’ to the confirmation prompt. WARNING: This action is not
reversible. Once you press ‘Y’ the old firmware is erased. (Press [ESC] to
cancel, if you changed your mind. The system will restart.)
7
IMPORTANT NOTE: Access over the Internet should be very carefully considered. When typing your password, it’s possible for
anyone with the necessary skills between you and your LogLock device to intercept your communication and copy your password.
Then they may be able to gain access to your system (specially if the system has a static IP address). For this reason, we strongly
advise against entering # mode over the Internet, but only do so from your local network for which it is assumed you have
administrator control and feel confident about how it is used. If you don’t understand the risks involved, please do not make your
LogLock accessible from outside your local network. If you have doubts even about your own local network, use a direct
connection from your PC to your LogLock using a cross UTP patch cable.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
41
6. Using HyperTerm (or similar application), send the firmware file to the device
using the ‘Send Text File’ (or similar) option. While the file is being
transferred, a series of dots appears. If there are any errors, the dot(s) are
replaced with special character(s) indicating the type of error that occurred. If all
goes well, the dots will terminate with an exclamation point (!) and the message
‘Loaded’. The system will auto-restart with the new firmware.
7. Re-establish the telnet connection that was lost due to the previous restart.
8. If you had made a backup before the upgrade, send the backup file to the device
to restore it to its previous configuration state. If loading an earlier firmware,
you may encounter compatibility issues trying to send the backup file to the
device. Newer versions are backwards compatible, so sending a backup file
created from a previous firmware should be recognized without problems
(unless specifically noted otherwise).
If the upgrade procedure fails for whatever reason (e.g., power-failure half-way during
the process), the system will re-start to the bOS8 monitor application and a slightly
different procedure is required to load the new firmware. If when the device starts,
instead of the usual welcome screen you see the bOS8 welcome screen, then follow
these instructions:
Give the LOAD command
Answer ‘Y’ to the prompt, if asked.
Go to Step 6 of the normal upgrade procedure.
Under some rare conditions, and following an incomplete firmware upgrade, it is still
possible that this second method can’t be used. There is still a third method to recover.
This is slightly more involved as it requires a few extra steps of changing a specific DS
Manager parameter, and detailed instructions will be provided on an as-needed basis.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
42
About the Alarm feature
The alarm feature is not meant to replace a regular alarm system, as it currently does not
have all the needed features normally found in such systems. Its purpose is somewhat
different; it is there to help notice when people enter or exit without using their keys, or
if someone left the door open after using it. As an example, it can alert an office
security guard or doorman that someone is trying to enter or exit without the correct
procedure (using their key), or that the door was left open after last being use. With an
active alarm the guard does not need to have his/her full attention at the door, but only
when the alarm sounds.
An external alarm device (either the actual siren/buzzer, or an input to the controller of
a separate dedicated alarm system) and a door-left-open detection switch must be
connected at the corresponding pins for this feature to work.
When the alarm feature is enabled (i.e., ALARM On delay not zero), the alarm sounds
either immediately if the door is opened without a key, or after the specified delay if
using a key. The alarm delay starts counting from the moment the door strike is
activated, not from the time the door strike is again deactivated at the end of the DT time.
In other words, it runs concurrently with the DT time. If the alarm timeout is set to
anything less than the DT time (and provided the door is still open), the alarm will start
before the strike stops.
While the alarm is active (i.e., sounding), the DIR screen shows the message [ACTIVE]
next to the alarm time setting. This allows you to know from a distance if there is
currently an alarm event.
The alarm stops as soon as the door closes, or a valid key is used for entry or exit, or a
REN/REX command is issued. To stop the alarm event for the specified alarm time, the
key must be both registered in the system and allowed for the specific time zone. In
other words, it must able to open the door at that specific moment in time. An Off delay
is possible with the ALARM command. The Off delay is zero by default (for compatibility
with previous versions). If the Off delay is non-zero, the alarm will not stop until after
this much time has elapsed from the moment the alarm condition stopped, e.g., by
closing the door. So, a quick open/close of the door without using a key sounds the
alarm for at least that many seconds. You can stop the alarm by presenting a valid key
or issuing a REN/REX command (an easy way to temporarily suspend the alarm).
A single alarm is used both for entry and exit (in case you are using the S2 mode) and
all door-left-open detection switches must be connected in series.
The alarm is not active during manual or automatic ENTRY and/or EXIT commands
(unless the Off delay from a previous alarm has not run out yet), or during REN/REX
commands (which cancel any active alarm immediately). For the LogLock Mini
version, the RX pin is used for the door switch, and the TX pin is used for the alarm
signal. These are located on a separate header. An appropriate driver must be used on
the TX pin to drive the external alarm or relay. WARNING: Do NOT connect the TX
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
43
pin directly, or you will cause irreparable damage to the device. Both the door-leftopen switch (RX) and alarm (TX) pins are active high.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
44
Installation Instructions
IMPORTANT: ONLY a qualified person (someone experienced in bare electronic PCB
handling) must perform the installation of LogLock. Do not attempt installation
yourself unless you know what you are doing, or else there is increased probability of
damage to the device due to wrong connections.
Custom units may have different installation requirements. Select the location on the
wall or door casing you want to install the readers. It must be somewhere near the door,
and at a height such that all users can easily access without having to either stand on
their toe tips or bend down. The unit can be placed anywhere inside the protected area,
at a distance not exceeding 100m (using UTP CAT5 cable) or shorter (plain twisted
pair.)
All LogLock units come with a 10/100Mbps Ethernet adapter. Connect it to a
hub/switch or PC using standard Ethernet UTP cable. Use cross cable for direct PC
connection. From the tdst-5-05-00-x86.exe file on the accompanying CD (or
Internet download as instructed, if a CD was not provided), install only the “DS
Manager” application and run it. Your “DS Manager Settings” should be similar to the
following pictures (but certain parameters, such as the IP address, may be different
depending on your specific network setup):
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
45
Multiple devices may be showing. Double-click on the specific device you want to
change.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
46
Owner name and device name are optional and can be set to your liking. The device
name can indicate which access point it controls (e.g., CompRoom).
MAC address is changeable but should be unique. Do not change unless you really
know why.
DHCP can be enabled or disabled depending on whether you want your device to obtain
an IP address dynamically from the network’s DHCP server, or manually.
Port should be any valid port number (i.e., a number from 1 to 65534), and there is
really no reason to change it from the default (1001).
Gateway is your network’s router IP address, or PC address, if connected directly
through a cross cable.
Subnet mask is again network specific. If you’re unsure what to use for gateway and
mask, issue the IPCONFIG command from the command console, and use the same
numbers as your PC’s.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
47
In the connection Tab, it’s important to set the Transport protocol to TCP. Connection
timeout is up to you, depending on your application (a zero disables timeout). Routing
Mode should be “0-Server (Slave)”. Unless you want to accept connections from only
a single IP address, leave the ‘Accept connection from’ box to ‘Any IP-address’.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
48
In the Serial port Tab, it’s important that you make the following settings the same as
shown above:
Serial interface, RTS/CTS flow control, DTR mode, Power-up DTR state, Baud rate,
Parity, and Data bits. These should already have the correct settings but if you
inadvertently changed them you can restore them to the ones shown above.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
49
In the Outbound Packets Tab, use the above preferred settings. ‘Start on any char’
should always be set to 1-Yes. Various settings in this tab may work, but the ones
shown work best.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
50
Press Save if you want to make a backup file of this configuration on your PC (to load
perhaps into another device). Finally, press OK to send the configuration to the device.
Changes sent to the device are remembered across power cycling. Any active
connection is lost.
IMPORTANT: DS Manager cannot auto-detect devices across a router. Your devices
must be in the same network segment.
Restarting the unit, you should see the LCD light up (if an appropriate LCD is
connected) and the terminal screen welcome you with a copyright message and the
firmware version of your unit. You’re done! Because the Ethernet module itself is
reset, your connection is lost and it must be re-established.
Press ?[ENTER] on the terminal to see the unit’s command help screen. If nothing
appears check your connections and settings.
Hint: To connect using HyperTerm, press the Connection Properties button, select
TCP/IP connection (rather than a COM port), and enter the corresponding IP or
domain name and port number (default 1001).
For any questions or first-time programming of the unit please write or call us.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
51
REVISION HISTORY (most recent at the top) [earliest purchase date in brackets]
v3.53: bOS8 v1.80 [2010.07.29]
1. Fixed issue with showing “Searching” when in LCD2 mode, if exit iButton is
not allowed (zone 255).
v3.52: bOS8 v1.80 [2010.05.06]
1. Internal optimizations.
v3.51: bOS8 v1.80 [2010.04.16]
2.
3.
4.
5.
Added manual command (DZU) to delete users assigned to specific zone.
Added password delay on wrong MASTER_RESET codes.
Push Button records date of addition for non-zero zones.
PBZ command now defaults to zero zone.
v3.50: bOS8 v1.80 [2010.04.10]
1. Optimized log wrap-around method (which occurs every time the log becomes
full) to make it practically instantaneous. Major Internal Change.
2. Improved long-term log memory durability by using fewer overall memory
writes.
3. Made Date Range restricted log display’s response time practically
instantaneous.
4. Internal optimizations.
v3.45: bOS8 v1.80 [2010.03.12]
1. Removed “Low Battery” warning during name display on the LCD.
2. Internal optimizations.
v3.44: bOS8 v1.80 [2010.03.09]
1.
2.
3.
4.
Added bi-directional LCD capability (mostly, for use as time-attendance only).
Added LCD1 and LCD2 commands to control [1] above.
Added auto-clearing of username from LCD after several (10) seconds.
Internal optimizations.
v3.44: bOS8 v1.80 [2010.03.09]
1.
2.
3.
4.
Added bi-directional LCD capability (mostly, for use as time-attendance only).
Added LCD1 and LCD2 commands to control [1] above.
Added auto-clearing of username from LCD after several (10) seconds.
Internal optimizations.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
52
v3.43: bOS8 v1.80 [2010.03.05]
1. Fixed “Low Battery” warning so it goes away.
2. Internal optimizations.
v3.42: bOS8 v1.71 [2009.11.14]
1. Setting a wrong clock will display the word “incorrectly”.
2. Added “Build” date on copyright message.
v3.41: bOS8 v1.71 [2009.10.01]
1. Bug fix: Disallowed zone 255 from manual AUTO command (which caused a
system stall due to the impossibility of the situation).
v3.40: bOS8 v1.70 [2009.08.27]
1. Disallowed zone 255 exits.
2. Increased device name length to 60 characters.
3. Internal optimizations.
v3.39: bOS8 v1.6x [2009.05.25]
1. Added manual auto-exit for specific zone including zero zone. To use, follow
the command AUTO with a zone number. This works regardless if the auto-exit
mode is currently enabled or disabled.
2. Z command now prints ERROR on wrong zone number.
3. Added PASS Attempts counter in DIR screen.
4. Added Resets counter in DIR screen.
v3.38: bOS8 v1.50/1.40 [2009.05.20]
1. Added 5-second delay after each failed password attempt. This severely inhibits
brute force attack methods as it takes more than 3.33E48 years to go through
just half of all possible codes. [Regardless, it’s wise to define long passwords
using a wide variety of characters, spaces, letters, numbers, and punctuation
marks.]
v3.37: bOS8 v1.50/1.40 [2009.05.19]
1. Internal optimizations.
2. Several changes in various informational messages (help screens, etc.)
3. Provided the LOCK and PASS passwords are different, giving the PASS password
from locked mode takes you straight to config mode, bypassing normal mode.
This means you can still enter config mode, even if the LOCK password is
forgotten. For best security, the LOCK and PASS passwords should be different,
especially if more than one person uses the LogLock terminal.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
53
v3.36: bOS8 v1.50/1.40 [2009.05.18]
1. Added ‘wildcard’ Starting/Ending dates in AU command. The YY, MM, DD or a
combination of these date elements may be wildcarded (using .. instead of the
corresponding number) for a much wider range of possibilities, such as entry
every first Monday of every month (in combination with appropriate zone
entry), only Februaries every year, from March to May every year, etc.
v3.35: bOS8 v1.50/1.40 [2009.05.13]
1. The WHO command no longer shows attempted entries, only successful ones. Use
the LAST command, instead, if you need to look at attempted entries.
2. On a similar note, auto-exit will not apply to attempted entries, only true entries.
v3.34: bOS8 v1.50/1.40 [2009.05.12]
1. Bug fix for v3.33 addition. The auto-exit would only do one person at a time
even when several people should be exited together.
v3.33: bOS8 v1.50/1.40 [2009.05.11]
1. Internal optimizations
2. Added capability for auto-exit for selected zone entries. Added new commands
AUTO and NOAUTO as well as AUTO parameter to AZ command.
v3.32: bOS8 v1.50/1.40 [2009.05.05]
1. Internal optimizations
2. DEVICE command works in LOCK mode to help identify the machine for using
appropriate password. (INFO showed the string, already, but DEVICE command
was not accepted.)
3. Zones can now be set with just the holiday bit to define a holiday-only schedule,
e.g.,
AH 20 -MTWTF-- 0900 1700
AH 20 -------H 0900 1700
will allow those in zone 20 to enter on any holiday from 09:00 to 17:00
regardless of day-of-week (i.e., even Saturdays and Sundays in this example,
provided these fall on defined holidays), and weekdays from 09:00 to 17:00.
This is different from
AH 20 -MTWTF-H 0900 1700
which allows entry on Mon-Fri from 09:00 to 17:00 regardless if the day is a
holiday or not, but which will never allow access on Saturdays and Sundays.
v3.31: bOS8 v1.50/1.40 [2009.05.04]
1. Invalid clock condition is immediate (even when setting clock) when year is
anything < 9.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd. 54
2. When truncating a full Log, automatically re-apply the current D command date
range.
3. Count number of alarm events (up to 255) and show counter in DIR screen.
4. Added CLEAR command to zero the alarm counter.
5. Added DEVICE command to show, change, or remove device name / comment.
Use ? for name to remove. The DEVICE string, if defined, is also shown in the
INFO screen.
6. D command now interprets the symbol * as today's date, e.g., use: D * for
quickly setting the range From Date to today.
v3.30: bOS8 v1.50/1.40 [2009.04.28]
1. When the clock is invalid (see v3.29 details) logging is disabled.
2. Improved REN/REX debounce.
3. Disallowed stuck REN/REX switch from opening the door continuously. The
REN/REX switch must be released before another REN/REX switch event is
accepted. A stuck switch no longer affects the manual REN/REX commands.
4. Monitor mode did not show username in HIDE mode. HIDE mode should only
hide the username from the LCD, besides hiding user IDs in user mode.
v3.29: bOS8 v1.50/1.40 [2009.04.28]
1. When the clock information is lost due to a power-on reset with a failed clock
backup battery, the status LED will blink rapidly, and the DIR display will show
[INVALID] next to the time. When in this error condition only zero zone people
will be allowed access since date/time cannot be trusted for zoned access.
Setting the clock clears the error condition.
v3.28: bOS8 v1.50/1.40 [2009.04.20]
1. Added optional delay for stopping an alarm event. Once the alarm goes off it
won't stop until this delay expires, or a successful access occurs (valid key or
allowed REN/REX command).
v3.27: bOS8 v1.50 [2009.04.10]
1. Added Serial Number display for units based on bOS8 v1.50 (which is otherwise
100% compatible to bOS8 v1.40)
v3.26: bOS8 v1.40 [2009.04.09]
1. Removed the implicit HELP command (pressing [ENTER] on a blank line). To
display the help screen, one of the two explicit commands, ? or HELP must be
used. This little change helps some telnet terminals that send extra characters on
Linefeed from not choking due to unexpected repeated help messages on
receiving a file (such as a backup) via a Paste operation.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
55
2. LOCK command is now completely ignored in user mode (as it didn't do anything,
anyway). It's only active in locked mode (for entering user mode) and config
mode (for changing the LOCK password).
v3.25: bOS8 v1.40 [2009.04.08]
1. Made PASS a synonym for LOCK when in terminal locked mode.
v3.24: bOS8 v1.40 [2009.04.06]
1. Added display of username in Monitor mode.
2. Made LOCK command visible only in config mode help.
v3.23: bOS8 v1.40 [2009.04.04]
1. Improvement on a privacy issue. Added the new command LOCK for defining an
optional password for terminal access (which may be different from the config
password). A NOPASS command from the [>] mode will go into locked mode
indicated by the prompt [!]. In locked mode, only the following harmless
commands are available: ANSI, CLS, INFO, REM, LOCK, and MASTER-RESET.
[MASTER_RESET is available in all modes in case one is ever locked out by
forgotten password(s).] Only the INFO command is shown in the help screen,
however. Locked mode protects from casual browsing of settings or the user
and log lists by chance visitors (e.g., if the unit is accessible over the Internet).
Only in config mode, one can [re-]define the LOCK password.
2. MASTER-RESET updated to clear both passwords (PASS and LOCK).
v3.22: bOS8 v1.40 [2009.03.26]
1. Fixed minor bug with not being able to add the 256th holiday.
v3.21: bOS8 v1.40 [2009.03.24]
1. Zoned EXIT in S1 mode is now auxiliary output (i.e., not for exit).
2. NOENTRY and NOEXIT no longer attempt to close on non-zero ENTRY or EXIT,
respectively.
v3.20: bOS8 v1.40 [2009.03.19]
1. Added command MU to Move User to another zone.
2. Added current alarm status in DIR screen.
v3.19: bOS8 v1.40 [2009.03.19]
1. Added command LAST. Similar to WHO but shows any action, not just entries.
2. REM command no longer prints the message that follows it.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
56
v3.18: bOS8 v1.40 [2009.03.09]
1. Fixed a small bug with the alarm sounding even during a REN/REX event.
2. Minor cosmetic change in backup files.
3. Manual ENTRY & EXIT now print ‘ERROR’ if set for automatic use (zone <>
zero).
v3.17: bOS8 v1.40 [2009.03.04]
1. Improved battery charging.
v3.16: bOS8 v1.40 [2009.02.26]
1. Added Push Button capability.
v3.15: bOS8 v1.40 [2009.01.26]
1. Added REM command.
2. Fixed first time alarm to use defined alarm time.
v3.14: bOS8 v1.40 [2009.01.24]
1. Alarm no longer sounds during ENTRY/EXIT commands (manual/automatic).
v3.13: bOS8 v1.40 [2009.01.22]
1. Added ALARM command and door-open detection.
v3.12: bOS8 v1.40 [2009.01.09]
1. Added "I'm alive" pulse to main LED.
v3.11: bOS8 v1.40 [2008.12.29]
1. Internal optimizations.
v3.10: bOS8 v1.40 [2008.12.28]
1. Zero DT does not attempt to open door (short pulse eliminated).
v3.09: bOS8 v1.40 [2008.12.28]
1. Internal optimizations.
v3.08: bOS8 v1.40 [2008.12.28]
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
57
1. Added automatic reset of iButton readers when losing connection in
Monitor mode.
v3.07: bOS8 v1.40 [2008.12.28]
1. Monitor mode has 1 min limit in normal mode, 24 hour limit in config
mode.
v3.06: bOS8 v1.40 [2008.12.28]
1. Hide username from LCD in HIDE mode.
v3.05: bOS8 v1.40 [2008.12.28]
1. Internal optimizations.
v3.04: bOS8 v1.40 [2008.12.28]
1. Added brief LED blink when reading iButton keys.
v3.03: bOS8 v1.30 [2008.12.02]
1. Added half-sec delay after iButton before opening door.
v3.02: bOS8 v1.20 [2008.12.01]
1. Added TEMP command (for OEM use, mostly).
v3.01: bOS8 v1.10 [2008.11.20]
1.
2.
3.
4.
Added full Greek alphabet conversion.
Added HIDE command.
Added separate DT delays for entry and exit.
Added separate AC/DC mode for entry and exit.
v3.00: bOS8 v1.00 [2008.10.01]
Original LogLock 3000/Mini firmware based on LogLock 2000 v2.54.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
58
Possible compatibility issues with older LogLock 2000 versions.
1. The ENTRY and EXIT commands are more powerful, and a zone number may follow
them. The OEM default is 255, which practically disables the commands. To make the
system behave the same, as with original firmware, you must first assign zone 0 (zero)
to both ENTRY and EXIT and save the changes using the SAVE command (if they must
survive a RESET).
2. Lines in original firmware ended with CR|LF pairs but used single LF characters to
advance additional lines (e.g., the sequence CR|LF|LF was possible). Current firmware
uses a CR|LF pair for each new line (e.g., CR|LF|CR|LF). This should not cause a
problem unless your custom software specifically expects a sequence of consecutive LF
characters based on previous observations of the actual data stream.
3. Inputs were accepted on lines ending with either CR or LF. Now, only CR can be used
to end an input line, LF is ignored. This change offers better telnet behavior with
applications other than HyperTerm. If the command you sent from your custom
application ended with just an LF, you must change it to a CR character, which will work
both with current and previous versions.
4. The DIR and HELP output screens may change slightly from version to version to
accommodate new commands or options. If your software expects a specific output
from the DIR screen in particular, you'll have to allow for the changes by examining the
new DIR output.
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
59
CONNECTIVITY DETAILS
The following table shows the pin out for the PCB (shown simulated on the next page).
If you need assistance, please contact us before attempting to make possibly
incorrect connections, which may damage the device.
Name
i1
iB
i2
+V
GND
LC1+
LC1LC2+
LC2REN
REX
BUTTON
Ethernet
TX
GND
RX
Description
iButton Reader #1 (primary – entry) gray reader cable
Common iButton Reader Ground (black reader cable)
iButton Reader #2 (secondary – exit) gray reader cable
Power Supply 9-12VDC positive (3 Amps max, depends on strike)
Common Ground
Primary door strike [entries] (positive lead)
Primary door strike [entries] (negative lead)
Secondary door strike [exits] (positive lead)
Secondary door strike [exits] (negative lead)
Optional Request-to-Enter push-button (same as REN command)
Optional Request-to-Exit push-button (same as REX command)
Push-Button for adding ‘guest’ users (optionally enabled)
Standard Ethernet connectivity jack RJ45 - 10/100Mbps
Alarm output (High=Alarm). Use appropriate FET/transistor to drive external siren.
Common Ground for TX / RX pins
Door-left-open switch (Low=door is closed)
Note: LC1/LC2 polarity is not significant for AC strikes. It is important for relays, however.
LogLock Mini LCD pin-out.
For correct operation (if adding the LCD yourself), please use only a 20x4 (20 characters
per line, 4 line) LCD with a compatible pin out.
PIN Number
1
2
3
4
5
6
7-14
15
16
Pin Description
GND (This pin is clearly marked on the LCD header with “1”)
+5V
Contrast
RS = Register Select
R/W = Read /Write
E = Enable
D0..D7 = Data0 .. Data7
Backlight +
Backlight -
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
60
LogLock 3000 PCB
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
61
LogLock Mini PCB
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
62
LogLock User Manual, October 10, 2013, Copyright  2002-2013 ASPiSYS Ltd.
63