Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages. ENDA EC442 UP/DOWN COUNTER Thank you for choosing ENDA EC442 COUNTER. * 48x48mm sized. * 2x4 digits display. * Easy to use by front panel keypad. * Counting up and down with a 2 channel inputs having a 90° phase shift. * Input frequency can be selectable. * Prescaler factor can be adjusted between 0.001 and 9.999. * Decimal point can be adjusted between 1. and 3. digits. * Sensor type can be selected as PNP, NPN or Encoder. * Single set-point control is made by a single relay output. * Output can be energized continuously or just for a time interval of 0.1 to 999.9 seconds. * Selectable functional reset input. * Input offset feature. * Parameter access protection on 3 levels. * Easy connection by removable screw terminal. * CE marked according to European Norms. EC 442 OUT PV SV SET PRESET ENDA RESET PRESET UP/DOWN COUNTER Order Code : EC442- 1 Supply Voltage 230VAC...230V AC 24VAC.....24V AC SM...........9-30V DC / 7-24V AC TECHNICAL SPECIFICATIONS ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50°C/-25 ... +70°C (with no icing) 80% up to 31°C decreasing linearly 50% at 40°C. Max. relative humidity According to EN 60529 Front panel : IP65 Rated pollution degree Rear panel : IP20 Height Max. 2000m Do not use the device in locations subject to corrosive and flammable gases. ELECTRICAL CHARACTERISTICS Supply Power consumption Wiring Date retention EMC Safety requirements 230V AC +10% -20% or 24V AC ±10%, 50/60Hz or optional 9-30V DC / 7-24V AC ±10% SMPS module. Max. 5VA 2.5mm² screw-terminal connections EEPROM (Min. 10 years) EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard) EN 61010-1: 2001 (pollution degree 2, overvoltage category II) INPUTS Count inpus (CP1, CP2) Frequency (Hz) Minimum On and Off times for pulses Reset input 2 channels (max. 9999Hz, 5V to 30V pulse) 25, 500, 1000, 2000, 5000, 7500Hz, 9999Hz (selectable by programming) 20ms for f=25Hz 1ms for f=500Hz 500m s for f=1kHz 250m s for f=2kHz 100m s for f=5kHz 67m s for f=7,5kHz 50m s for f=10kHz PNP: Positive reset (5V to 30V pulse with adjustable pulse time between 2ms and 50ms) NPN: GND terminal is connected to the RESET IN terminal. OUTPUTS Relay : 250V AC, 2A (for resistive load), NO+NC Open collector output (S.S. OUT): Max. 30V DC, 100mA 12V DC, max. 50mA (without regulation) Auxiliary power supply Mechanical 30.000.000 operation; Electrical 300.000 operation Life expectancy for relay Note : Relay and S.S.OUT outputs are in synchronization . When OUT relay is energized S.S. OUT transistor goes into saturation. Control output (OUT) HOUSING Housing type Dimensions Weight Enclosure material Suitable for flush-panel mounting according to DIN 43 700. W48xH48xD87mm Approx. 210g (after packing) Self extinguishing plastics While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used. 1/5 EC442-E-07-R TERMS EC 442 OUT (1) Counting value during run mode. Parameter value or mnemonic parameter code during programming mode. (2) Preset value during run mode. Parameter value, unit or mnemonic parameter code during programming mode. (3) Output LED. PV SV (4) Increment key during run and programming modes. Parameter selection key during programming mode. (5) Decrement or reset key during run mode. Parameter selection or decrement key during programming mode. (6) Used for selecting options or digits to be changed. SET PRESET ENDA RESET PRESET UP/DOWN COUNTER (7) Used for selecting run or programming modes or for adjusting the parameter. ( 1 ) PV display ( 2 ) SV display 4 digits, seven segment red LED 4 digits, seven segment yellow LED PV display (1) : 7.1mm SV display (2) : 7.1mm One red LED Character height ( 3 ) Output LED ( 4 ),( 5 ),( 6 ),( 7 ) Keypad Micro switch Depth DIMENSIONS Panel cut-out 1 2 51mm EC 442 +0.6 45 48mm mm PV mm SV SET PRESET ENDA 45 +0.6 58mm OUT RESET PRESET UP/DOWN COUNTER 80mm 1 Connection cables For removing the device from the panel: - While pressing both side of the device in direction 1, push it in direction 2. Flush mounting clamp Note: 1) While panel mounting, additional distance required for connection cables should be considered. 2) Panel thickness should be maximum 9mm. 3) If there is no 100mm free space at back side of the device, it would be difficult to remove it from the panel. Panel CONNECTION DIAGRAM ENDA EC442 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The shielding must be grounded on the instrument side. During an installation, all of the cables that are connected to the device must be free of energy. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be close to the power cables or components. The installation and electrical connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations. ENDA INDUSTRIAL ELECTRONICS EC442-230VAC PRESET UP/DOWN COUNTER 8 S.S. OUT 2 9 RESET IN 3 10 CP2 INPUT 4 11 CP1 INPUT 5 12 ENDA INDUSTRIAL ELECTRONICS ENDA INDUSTRIAL ELECTRONICS EC442-24VAC PRESET UP/DOWN COUNTER EC442-SM PRESET UP/DOWN COUNTER 8 230V AC +10% -20% 50/60Hz 5VA OUT1 AC 250V 2A RESISTIVE LOAD S.S. OUT 2 9 RESET IN 3 10 CP2 INPUT 4 11 CP1 INPUT 5 12 8 24V AC ±10 50/60Hz 5VA OUT1 AC 250V 2A RESISTIVE LOAD S.S. OUT 2 9 RESET IN 3 10 CP2 INPUT 4 11 CP1 INPUT 5 12 GND 6 GND 6 GND 6 +12V 30mA 7 +12V 30mA 7 +12V 30mA 7 SN: XXXXXXXXX SN: XXXXXXXXX NOTE : Fuse F 100 mA 250V AC SUPPLY: 184-253V AC 8 50/60Hz 5VA 9 Line Neutral OUT1 AC 250V 2A RESISTIVE LOAD Holding screw 0.4-0.5Nm Equipment is protected throughout by DOUBLE INSULATION. SN: XXXXXXXXX Note : 1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245. 2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator. Switch 230V AC Supply Fuse should be connected. 9-30V DC / 7-24V AC ±10 % 5VA Cable size: 1,5mm² 2/5 EC442-E-07-R Run mode 1000 P.SEt Preset value See NOTE 1. for adjustment. SET SET if PRG key is pressed while holding CP1.U. CP2.G. Cntr. dir. dirE. oPPo. inPt. Frq. 25 Hert 500 Hert 1000 Hert SEnS. tyPE nPn PnP Enco. r.est puls OuTP. oPTi. 1000 CP1.U. CP2.U. outP. typE out ti. key, the 0.002 sec. ConF. 1 000.0 CP1.U. CP2.r. 2000 Hert UP Ph-4 5000 Hert 0.005 sec. 0.010 sec. 0.020 sec. 0.050 sec. ConF. 2 ConF. 4 ConF. 5 ConF. 6 .......... UP.dn. Ph-1 7500 Hert ConF. 7 UP.dn. Ph-2 disP. oPTi. Counting value is on the upper display. Preset value is on the lower display. CP1.U. CP2.d. 9999 Hert ConF. 8 ConF. 9 ConF. 10 SECU. oPTi. INPT. oPTi. 9999 PRESET PARAMETER TABLE inPt. typE 999.9 PRESET dEci. Pnt. 0 diSP. CAL. 0.001 ......... 9.999 oFFS. dAtA 0 ......... 5000 SECU. codE 1111 inP.o SECU. nonE Prog. no Prog. yES Out.o. SECU. nonE Prog. no Prog. yES diS.o. SECU. nonE Prog. no Prog. yES Cntr. r.SEt no PAnE. r.SEt r.SEt inP.t. def. SEt no yes 0.0 0.00 0.000 both programming mode is enabled. ýnPt. OutP. oPti. dýsP. oPti. PRESET RESET typE There are nine different output types. A schematic diagram of output types is at the next page. See NOTE 2 for modification. outP. typE Counting direction can be selected dirE. or oPPo. A schematic diagram of counting directions according to the selected input types is at the next page. See NOTE 2 for modification. dýr. RESET Pnt. tý. dýsP. CAL. oPti. PRESET RESET Decimal point can be adjusted between 1. and 3. digits. If desired, decimal point is not included. See NOTE 2 for modification. SECU. codE RESET RESET Output energizing time can be adjusted between 0.1 and 999.9 seconds. If it is made 0.0, output is energized continuously when P.SEt value is reached. See NOTE 1 for modification. out Calibration (Prescaler) value can be adjusted between 0.001 and 9.999. Counter multiplies the number of pulses by the prescaler value and the result is displayed on the screen See NOTE 1 for modification. ýnP.o SECU. Access code for entering security option menu. This parameter should be 1111. See NOTE 2 for modification. nonE Prog. no Prog. yES = No menu is seen. = Menu is seen but can not be programmed. = Menu is seen and programming is possible. See NOT 2. for modification. RESET RESET oFFS. Input frequency can be selected. See NOTE 2 for modification. Frq. dEcý. RESET RESET Cntr. ýnPt. PRESET RESET RESET There are seven different input types. A schematic diagram of counting modes according to the input types is at the next page. See NOTE 2 for modification. ýnPt. SECU. oPti. PRESET dAtA Offset value can be adjusted between 0 and 5000. It means counter starts counting from the offset value when it is reset. See NOTE 1 for modification. out.o. SECU. nonE Prog. no Prog. yES = No menu is seen. = Menu is seen but can not be programmed. = Menu is seen and programming is possible. See NOT 2. for modification. RESET RESET SEnS. dýs.o. A type of sensor can be selected. See NOTE 2 for modification. tyPE SECU. nonE Prog. no Prog. yES = No menu is seen. = Menu is seen but can not be programmed. = Menu is seen and programming is possible. See NOT 2. for modification. RESET RESET The minimum pulse duration of the external RESET input can be selected. See NOTE 2 for modification. R.set puls Cntr. r.SEt no PAnE. r.SEt r.SEt inP.t. both PARAMETER MODIFICATION DIAGRAM NOTE 1 Holding SET SET key the value of the selected parameter is seen on the display. While holding PRESET Selected numerical parameter keys. In order to reset all the digits, first press and hold key, the value of the selected parameter can be changed by key. And then, press both and keys together. SET SET 1.000 SET PRESET 1.000 SET SET PRESET 1.000 1.010 RESET SEt 1.000 = Both RESET input and the key can RESET be used for resetting. See NOT 2. for modification. def. RESET RESET key. RESET = Counter can be reset by the RESET input. RESET SET using = Counter can not be reset. = Counter can be reset by While leaving the programming mode, no = All the modifications are saved. Yes = Default values are set to parameters. See NOT 2. for modification. SET NOTE 2 To modify non-mumerical parameters, hold key and use keys. RESET 3/5 EC442-E-07-R INPUT TYPES ýnPt. tyPE Cntr. dýr. CP1.U. CP2.d. OUTPUT TYPES UP COUNTER dýrE. C o u n t input CP1 C o u n t input CP2 oPPo. C o u n t input CP1 C o u n t input CP2 H L H L n+4 n+3 n+3 n+3 DOWN COUNTER UP inPt. typE = CP2.U. , CP2.G. , Ph-4 Cntr. dir. = dirE. Cntr. dir. = oppo. CP1.U. CP1.U. UP UP / DOWN COUNTER inPt. = CP1.U. , CP1.U. , UP.dn. , UP.dn. typE CP2.d. CP2.r. Ph-1 Ph-2 Reset 9,999 Preset 0 n-2 DISPLAY n-2 n-3 n+1 Out n-3 n-3 n-4 n C o u n t input CP1 C o u n t input CP2 CP1.U. = CP2.U. , CP2.G. , Ph-4 n-1 n+2 n+2 DISPLAY Conf. 1 H L H L n CP1.U. inPt. typE Conf. 2 (HOLD ) C o u n t H input CP1 L C o u nHt input CP2 L H L H L CP1.U. CP2.U. 0 n n+7 n+6 Out n-1 n+5 n-2 n-3 n+3 DISPLAY Reset 9,999 Preset Conf. 4 (Autoreset ) DISPLAY n+2 n-5 n-6 n+1 n Reset 9,999 Preset 0 n-7 Out CP1.U. CP2.G. C o u n t input CP1 Ga t e input CP2 C o u n t input CP1 Ga t e input CP2 H L H L n+4 H L H L n n+3 DISPLAY DISPLAY n+2 n-1 n-2 n+1 n-3 n CP1.U. CP2.r. C o u n t input CP1 direction input CP2 C o u n t input CP1 dirction input CP2 Conf. 6 (Delayed Autoreset and HOLD) H L H L n+4 n n+3 n+3 n+3 n-1 n+2 n+2 DISPLAY n+1 n-2 n-3 n-4 C o u n t input CP1 C o u n t input CP2 H L H L n n+7 n-2 n+4 n-4 DISPLAY n-6 n-7 n+1 n n-8 C o u n t input CP1 C o u n t input CP2 H L H L Out n n+2 n+1 n+1 DISPLAY n-1 UP.dn. Ph-2 C o u n t input CP1 C o u n t input CP2 n+5 n+4 n+3 n-2 n-2 While counter value is lower or equal to the preset value, OUT is active. Preset 0 -999 Out n n-1 n-2 n+3 n+1 n-3 n-3 n+2 Reset 9,999 n-2 DISPLAY n-4 n-4 n-5 n NOTE :1) Conf. 9 H L H L n+4 n+2 DISPLAY Reset 9,999 n-1 n-3 H L H L While counter value is equal to preset value, OUT becomes active. Preset 0 -999 n C o u n t input CP1 C o u n t input CP2 Conf. 8 H L H L n+3 n+2 0 Reset 9,999 n-5 n+3 DISPLAY Reset 9,999 Preset n-3 n+2 UP.dn. Ph-1 0 Out inPt. = CP1.U. , CP1.U. , UP.dn. , UP.dn. typE CP2.d. CP2.r. Ph-1 Ph-2 n-1 n+5 C o u n t input CP1 C o u n t input CP2 Reset 9,999 Preset Out n+6 DISPLAY Conf. 7 (Autoreset and Display hold) H L H L n+8 UP Ph-4 0 n-2 n-3 n C o u n t input CP1 C o u n t input CP2 Reset 9,999 Preset Out n-4 H L H L DISPLAY Conf. 5 (Delayed Autoreset ) Conf. 10 -999 For PNP sensor, counter is triggered at the rising edge of the pulses. For NPN sensor counter is triggered at the falling edge of the pulses. Out Adjusting out to a value between 0.1 and 999.9 seconds, a pulse output is obtained. 2) For NPN sensor, if you select ýnPt.tyPE CP1.U. CP2.r. , above diagram for Cntr.dýr. DýrE replaces with Cntr.dýr OPPo. While counter value is greater or equal to the preset value, OUT is active. Preset 0 ti. . 4/5 Adjusting out to 0.0, a continuous output is obtained. ti. EC442-E-07-R TERMINAL CONNECTIONS ENDA INDUSTRIAL ELECTRONICS Terminal descriptions EC442-230VAC PRESET UP/DOWN COUNTER 8 S.S. OUT 2 9 RESET IN 3 10 CP2 INPUT 4 11 CP1 INPUT 5 12 2 : Solid state out (Max 30V 100mA, open collector NPN). 3 : Reset input. 4 : Input for clock pulse 2 (Max 30V 7.5kHz). 5 : Input for clock pulse 1 (Max 30V 7.5kHz). 6 : GND. 7 : +12V 30mA auxiliary power supply output for sensors. 8,9 : SUPPLY inputs. 10,11,12 : Relay contacts (Max 2A 250V AC). 230V AC +10% -20% 50/60Hz 5VA OUT AC 250V 2A RESISTIVE LOAD GND 6 +12V 30mA 7 SN: XXXXXXXXX TYPICAL SENSOR CONNECTIONS 8 Fuse F 100 mA 250V AC Switch 230V AC supply 2 PNP PROXIMITY SWITCH 9 Cable size: 1,5mm² OUT GND 3 10 4 11 5 12 6 + 12V 7 Fuse F 100 mA 250V AC Switch 8 230V AC supply PNP PROXIMITY SWITCH 2 9 Cable size: 1,5mm² OUT PNP PROXIMITY SWITCH OUT GND GND 3 10 4 11 5 12 6 + 12V + 12V 7 Fuse F 100 mA 250V AC Switch 8 2 ENCODER B OUT A OUT GND + 12V 9 3 10 4 11 5 12 230V AC supply Cable size: 1,5mm² 6 7 NOTE: NPN PROXIMITY SWITCH connection is the same as PNP PROXIMITY SWITCH connection. SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ. Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL-TÜRKÝYE Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 5/5 url : www.enda.com.tr EC442-E-07-R