Download PRODUCT OVERVIEW: CanarIT™ 1.0
Transcript
PRODUCT OVERVIEW: CanarIT™ 1.0 October 2012 1. PRODUCT OVERVIEW The CanarIT™ is a multi-sensor air quality monitoring device, designed for affordable network sensing – "a sensor web" – or as a single monitoring station. The main functionality of the device is to identify, alert and log air quality events that may pose risks to human health and the environment. The device continuously measures levels of air pollutants, and transmits the data over the Internet for cloudbased storage and processing. 2. DEVICE The CanarIT™ 0.1 device monitors; NO2 O3 - can be replaced (with additional cost) with: o Odour o Ammonia – NH3 o Carbon Monoxide-CO o Hydrogen- H2 o Hydrogen Sulfide- H2S o Methane- CH4 o Perchloroethylene- C4CI4 o Sulfur dioxide- SO2 Total Volatile Organic Compounds (T VOC) Total Suspended Particles / Dust (PM10) Noise Temperature Relative Humidity Size: Length – 26 cm, width 17 cm, height 7 cm. CanarIT™ 1.0: Page 1 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 The device sends data automatically and periodically over the Internet. The device user-interface is based on Web Pages and Google Earth/Maps. The unit is not operational if it is not connected to the Internet and to the AirBase cloud-based servers. 3. USER MANUAL The CanarIT is a plug & play multi-sensor unit with minimal human handling. After positioning the unit at the desired location all user-interface is done through our web page. No need to physically handle the unit. 4. INSTALLATION MANUAL The CanarIT unit is supplied in a special case. It is supplied with the following items: 1. 2. 3. 4. 5. 1 CanarIT 0.1 unit 1 electricity wire and currency adapter to 12v. USB wire Helen key Product overview & manual How to install: Please refer to CanarIT Installation guide. 5. POSITIONING Outdoor: The CanarIT needs to be positioned under shade from sun, and cover from rain. Balcony or window can be a good spots. Indoor: Try to position you sensor at the height level of the people/kids in the room. Page 2 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 6. MAINTANANCE MANUAL Every six months remove the unit from its location and clean its surface and sensors inputs with a regular vacuum. It is preferable not to disconnect it from the electricity, but if need the unit can be disconnected and then connected again with no need to reregister it. Calibration is being done remotely through the internet. 7. SERVICES Our service includes access to data for the device/s purchased via a web site. There are three service channels available for sensor buyers: 1. Master Page – shows streaming info. 2. Mail Alerts – single e-mail alert will be sent based on air quality exceeding a threshold (based on an average of last 30-minutes). 3. Raw Data Page - the device also produces ‘raw’ data that can be accessible in spreadsheet format and other communication formats and APIs. Consulting & Installation Support AirBase and its Certified Partners can provide consulting advice and installation support for the units. 4. VALIDATON AND CALIBR ATION The device undergoes an internal Quality Assurance process and is delivered when calibrated and ready for use. Any data calibration is performed remotely. There is no need for any physical work to be conducted on the device itself. In the case of repeated mal-readings, a new device will be sent to the customer. 5. SAFTY AND DISPOSAL The CanarIT™ device is equipped with two safety certifications: a. CE - The CE marking is a mandatory conformity mark for products placed on the market in the European Economic Area (EEA). With the CE marking on a product, the manufacturer ensures that the product conforms to the essential requirements of the applicable EC Directives. Page 3 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 b. FCC - FCC is the abbreviation for the Federal Communications Commission. The FCC is responsible for rating personal computers and other equipment as either Class A or Class B. The ratings indicate how much radiation a personal computer emits. Disposal of units Please do not dispose of the unit yourself. Contact us for recall or recycling procedures. If you are unable to contact AirBase, please treat the unit as ‘electronic waste’ and dispose of the device in a proper manner according to the local laws and regulations. 6. INTERNET CONNECTIVITY The CanarIT™ 0.1 has two different communication versions (each unit has only one preselected communication option); wireless Wi-Fi and wireless GSM (cellular). Each of the two communication options requires a different installation process. CANARIT™ WI-FI TECHNICAL INFORMATION Range 50-100 meter outdoor (Typical Estimate) Wi-Fi Certified Solution Compatible with IEEE 802.11b/g/n Supports 802.11i security Ambient temperature operating range: (-) 40 to (+) 85 [0c]. INSTALLATION The Wi-Fi CanarIT™ installation requires Wi-Fi network selection and entering a password key (if the network is not an open one). This is done by installing client software on a PC and connecting the CanarIT™ to the PC with a USB cable. The software interface on the PC will show all available networks in the given range and will request the password of the selected network. Once the USB cable is disconnected, the unit will start transmitting the data automatically. Specific instructions will be sent with the unit itself and our customer support will assist. CANARIT™ GSM (CELLULAR) GENERAL INFORMATION Network: GSM, GPRS Class 10 Band: Full Quad band Support: 850/900/1800/1900 MHz SIM: 3V & 1.8 V supported Page 4 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 Ambient temperature operating range: (-) 40 to (+)85 [0c]. INSTALLATION Plug and play. Simply insert the SIM card in the device and plug the device into a power supply. 7. EXTERNAL INTERFACES SERIAL COMMUNICATION Mini USB; used for the Wi-Fi network configurations. Once the USB port is connected to a PC, the unit is in automatically in Wi-Fi network selection mode, when the port is disconnected the unit shifts to transmission mode. POWER 12V DC, 250mA or more, 2.1mm plug, center pin positive. LED DISPLAY The unit has a LED display to mark the different modes of operation: Power On: Green Configuration Mode: Fast Yellow blinks Transmission mode: Slow yellow blinking (once every 20 seconds) 8. USER INTERFACE The CanarIT™ user interface is web-based; the only option to access the sensor information is from a webpage. Each device has an individual web page accessed by a unique URL. All sensor data is stored automatically on AirBase servers every 20 seconds (subject to change). In the webpage the user has the following options: Dynamic symbol on Google Earth / Maps, the symbol color is determined by the sensor’s results (i.e. good = green, moderate = yellow, bad = red). Dashboard with current status (gauge for each sensor) Ventilation instructions Pie chart of the sensor history showing distribution of good / moderate / bad conditions Graphs for each sensor. The graph displays results averaged every five minutes. The graph time range is user adjustable. Page 5 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 Microsoft Excel file generation based on time range definition and row data / average data every five minutes. Over time, we will be adding new features to the web services. 9. DISCLAIMER AirBase Systems LTD. maintains this website to enhance public access to air quality information in general. Our goal is to keep this information timely and accurate. AirBase Systems LTD. reserves the right not to be responsible for the topicality, correctness, completeness or quality of the information provided. If errors are brought to our attention, we will try to correct them. Parts of the pages or the complete publication including all information might be extended, changed or partly or completely deleted by the author without separate announcement. This information is: of a general nature only and is not intended to address the specific circumstances of any particular individual or entity; not necessarily comprehensive, complete, accurate or up to date; sometimes linked to external sites over which AirBase Systems LTD. has no control and for which AirBase Systems LTD. assumes no responsibility; not professional, medical or legal advice AirBase Systems LTD. is not responsible for any contents linked or referred to from these pages - unless it has full knowledge of illegal contents and would be able to prevent the visitors of its site from viewing those pages. AirBase Systems LTD. is not liable for any postings or messages published by users of discussion boards, guest books, social networks or mailing lists provided on its page. The copyright for any material created by AirBase Systems LTD. is reserved. Any duplication or use of such as images, diagrams, sounds or texts in other electronic or printed publications is not permitted without AirBase Systems LTD. agreement. This disclaimer is to be regarded as part of the internet publication which you were referred from. If sections or individual formulations of this text are not legal or correct, the content or validity of the other parts remain uninfluenced by this fact. 10. SENSING CAPABILITIES OZONE Page 6 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 The sensor is based on a nanotechnology-enhanced, gas-sensitive semiconductor to measure ozone in ambient air. The semiconductor is sensitive to ozone due to surface oxygen vacancies. Therefore, the sensing mechanism is based on decomposing the ozone, and filling of the vacancies, causing a measurable increase in resistance. PERFORMANCE Calibrated range: 0 – 150 or 0 – 500 [ppb], (fixed after order) Lower detection limit: 1 [ppb] Accuracy of calibration: 6.5 [ppb] Resolution: 1 [ppb] Respond time: 65 [sec] 0 Ambient temperature operating range: -5 to +40 [ c] Relative humidity operating range: 5 to 95 [%] COMPARISON WITH SCIENTIFIC REFERENCE INSTRUMENTS: Validation tests were exhibiting low drift and tracking similar trends to reference methods with readings almost identical within the specified accuracy level (<± 8 ppb from 0 to 0.1 ppm and <± 10% from 0.1 to 0.5 ppm). Reference instrument: Thermo Electron Model TEI 49C ozone analyzer utilizing UV photometer US EPA Designated Method EQOA-0880-047 NITROGEN OXIDE (NO2) NO2 sensors are produced by placing a semiconducting, nano-crystalline metal oxide on a substrate and measuring the conductivity. By adding dopants of noble metals, the sensitivity towards NO2 is influenced and allows a tuning of sensor performance for specific applications. The sensor uses the following principles: NO2 from ambient air is combusted at the sensor surface, reacting with oxygen atoms/molecules from the crystal lattice. Electrons, which are removed by this chemical reaction, lead to a lower conductivity of the semiconducting material. PERFORMANCE Calibrated range: 10 – 2000 [ppb] Lower detection limit: 10 [ppb] Resolution: 5 [ppb] Respond time: 200 [msec] Ambient temperature operating range: (-) 40 to (+) 85 [0c] Relative humidity operating range: 5 to 95 [%] VOLATILE ORGANIC COMPOUNDS (VOC) VOC sensors are produced by placing a semiconducting, nano-crystalline metal oxide on a substrate and measuring the conductivity. By adding dopants of noble metals, the sensitivity towards VOCs is influenced and allows a tuning of sensor performance for specific applications. The sensor uses the following principles: VOCs from ambient air are combusted at the sensor surface, reacting with oxygen atoms/molecules from the crystal lattice. Electrons, Page 7 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 which are released by this chemical reaction, lead to a higher conductivity of the semiconducting material. PERFORMANCE VOC's detected: Alcohols, aldehydes, ketones, organic acids, amines, aliphatic and aromatic hydrocarbons Respond time: seconds Ambient temperature operating range: (-) 40 to (+) 120 [0c] Relative humidity operating range: 5 to 95 [%] DYNAMIC RANGE Compound Formula Range [ppm] Potential Sources Carbon monoxide CO 0-10 Car exhaust, fuel-based heating, cooking appliances, smoking Methane CH4 0-200 Natural gas Propane C3H8 0-20 Fuel-based heating, cooking appliances, cleaners Ethyl alcohol C2H6O 0-3 Cosmetics, cleaners, disinfectants, detergents, paints, coatings, breath Acetaldehyde C2H4O 0-20 Adhesives, coatings, plastics, lubricants, ripening of fruits Methylethylketone C4H8O 0-20 Adhesives, coatings, plastics, lubricants C7H8 0-5 Paints, coatings, cleaners, detergents, smoking, polyurethane lacquers Toluene Page 8 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 Page 9 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 TOTAL SUSPENDED PARTICLES (TSP, I.E. DUST) The dust sensing principle is an optical sensing system. An infrared emitting diode (IRED) and a phototransistor are diagonally arranged into the device. It detects the reflected light of dust in air. It is especially effective in detecting very fine particles of substances such as cigarette smoke. In addition, it can distinguish smoke from house dust by the pulse pattern of output voltage. PERFORMANCE Sensitivity: 0.1 [mg/m3] Sensing pulse cycle: 10 [msec] Ambient temperature operating range: (-) 10 to (+)65 [0c] TEMPERATURE AND RELATIVE HUMIDITY This dual sensor is implemented in advanced semiconductor technology (CMOS) using specific micro system processing steps to produce the micro sensor structures on specially developed semiconductor parts. The relative humidity sensor element is built out of a capacitor. A polymer absorbs or releases water proportional to the relative environmental humidity, and thus changes the capacitance of the capacitor; this is called the dielectric. PERFORMANCE Resolution: 0.04 0C / 0.7% Relative humidity Accuracy: ±0.30C / ±2% relative humidity Repeatability: ±0.10C / ±0.1% relative humidity Maximal respond time: 30 sec Ambient temperature operating range: (-) 40 to (+) 125 [0c] Relative humidity operating range: 0 to 100 [%] NOISE The noise sensor is based on an electrets microphone. The sensor is designed to alert on sound nuisance or damaging levels only. PERFORMANCE Sensitivity: (-) 44 [dB] Directivity: Omni directional Sound to noise ratio: 55 [dB] Frequency range: 100 to 10,000 [Hz] Ambient temperature operating range: (-) 25 to (+) 45 [0c] Relative humidity operating range: 5 to 95 [%] Page 10 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 ODOR SENSOR (OPTIONAL) The sensor is based on a nanotechnology-enhanced, gas sensitive semiconductor to measure odor levels in ambient air. The module is calibrated against the European Odor Unit (OUE) concentration scale, which is based on the response to 40 ppb of n-butanol as defined in EN 13725. PERFORMANCE Dynamic Range: 0 – 5000 [OUE/m3] Sensitivity: 2 [OUE/m3] Resolution: 1 [OUE/m3] Ambient temperature operating range: (-) 10 to (+) 45 [0c]. Relative humidity operating range: 10 to 95 [%]. Page 11 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 APENDIX POLLUTANTS AND SOURCES Target Emission Sources Good for Nitrogen Dioxide (NO2) Fossil fuels combustion processes; motor vehicle, electricity generation, heating, cooking, etc. Personal and community health protection Household chemicals, solvent chemical process and fossil fuel combustion Personal and community health protection Total Volatile Organic Compounds (VOC) Traffic management Indoor air quality management. Traffic management Industrial emissions management Natural / man made airborne particles; soot, fine sand, etc. Dust Personal and community health protection Indoor air quality management Secondary product of the interaction between motor vehicle / industrial emissions and sunlight. Ozone (O3) Personal and community health protection Crop loss management Wildlife protection Temperature Relative Humidity & Weather and indoor elements Personal and community health protection Energy savings Weather forecasting Page 12 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 AMBIENT AIR QUALITY STANDARDS EEA (EU) Gases Levels CO 43 [ppm] / 50 [mg/m ] NO2 105[ppb] / 200[µg/m ] O3 6o[ppb] / 120[µg/m ] EPA (USA) Averaging Time Levels 3 0.5 hour 35 [ppm] / 40[mg/m ] 3 0.5 hour 0.5 hour 120[ppb] / 235[µg/m ] 3 Averaging Time 3 1 hour 53[ppb] / 100[µg/m ] 3 Annual mean 3 1 hour Page 13 of 13 pages Airbase Systems Ltd. Granot Initiative Center, Emeq Hefer 38100, Israel Tel/Fax +972-46218674 Kingfisher Business Park, London Road, Stroud, Gloucestershire GL5 2BY Tel: +44 (0) 1453 733200 Fax: +44 (0) 1453 733201 Email: [email protected]