Download Omega Vehicle Security PHCN-410 User's Manual

Transcript
OMEGA... Your Source f
Process Measurement and i&trol
TEMPERATURE
B Thermocouple, RTD & Thermistor
Probes, Connectors, Panels 81 Assemblies
B Wire: Thermocouple, RTD &Thermistor
m Calibrators & Ice Point References
B Recorders, Controllers & Process Monitors
B Infrared Pyrometers
PRESSURE/STRAIN FORCE
@’Transducers & Strain Gages
@ Load Cells & Pressure Gauges
@’ Displacement Transducers
0 Instrumentation & Accessories
DATA ACQUISITION
@’Data Acquisition and Engineering
HEATERS
0 Heating Cable
FLOW/ LEVEL
b? Rotameters, Gas Mass Blowmeters &
Plow Computers
0 Air Velocity Indicators
0 Turbine/Paddlewheel Systems
0 Totalizers & Batch Controllers
ENVIRONMENTAL MONITORING AND CONTROL
0 Metering & Control Instrumentation
& pH Electrodes, Testers & Accessories
@ Bet-&top/Laboratory Meters
0 Controllers, Calibrators, Simulators &
Pumps
0 Industrial pl-I Rr Conductivity Equipment
M1811/0694
pH Controller
Software
B Communications-Based Acquisition
Systems
0 Plug-in Cards for Apple, IBM &
Compatibles
0 Datalogging Systems
0 Recorders, Printers & Plotters
0 Cartridge & Strip Heaters
0 Immersion & Band Heaters
0 Flexible Heaters
0 I.aboratory Heaters
H/CONDUCTIVITY
PHCN-4 10
m Refractometers
0 Pumps &Tubing
0 Air, Soil & Water Monitors
0 Industrial Water & Wastewater
Treatment
@’ RI-l, Conductivity Fr Dissolved Oxygen
Instruments
MEOMEGA”]
Operator’s Man
pH Controller Operator ’s Manual
Servicing USA and Canada: Call OMEGA Toll Free
USA
Canada
One Omega Drive, Box 4047
976 Bergar
Stamford, CT 06907-0047 USA
LavaI (Quebec) H7L 5Al
Telephone: (203) 359-1660
Telephone: (514) 856-6928
FAX: (203) 359-7700
FAX: (514) 8566886
Sales Service: l-800-826-6342 / l-800-TC-OMEGASM
Customer Service: l-800-622-2378 / l-BOO-622-BESTS”
Engineering Service: l-806-872-9436 / l-SOO-USA-WHENsM
TELEX: 996404 EASYLINK: 62968934 CABLE OMEGA
SECTION
Section 1 Getting Started
Servicing Europe: United Kingdom Sales and Distribution Center
2.5 Swarmington Road, Broughton AstIey, L&ester&&e
LE9 6TU, England
Telephone: 44 (0455) 285520
FAXz 44 (0455) 283912
-~‘“c:P,x%$?~.q~?~zY?~
G.<:>b:,:.+, ..,, I ._ <..,<_.,,,~_.~:..,, RmUR N REQUESTS / INQUIRIES ~~~~~~~:s~~~~~~~~~~~
Direct all warranty and repair requests/inquiries to the
OMEGA ENGlNEEAtNG Customer Service Department.
Call toll free in the USA and Canada:
1-800-622-2378. FAX: 203-359-7811; International: 203-359-1660. FAX:
203-359-7807.
BEFORE RETURNtNG ANY PRODUCT(S) TO OMEGA, YOU MUST OBTAIN AN
AUTHORtZED RETURN (AR)
NUMBER FROM OUR CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESStNG DELAYS).
The assigned AR number should then be marked on
me outside of the return package and on any correspondence.
FOR w RETURNS. please have the
folFOR B REPAIRS OR CALIBRATION.
towing information available BEFORE contacting
consult OMEGA for current repair/calibration charges.
OMEGA:
Have the following information available BEFORE contacting OMEGA:
1. P.O. number under which the product was
PURCHASED,
1. P.O. number to cover the COST of the of the
2. Model and serial number of the product under
reoairlcalibration.
warranty, and
2. Model and serial number of product, and
3. Repair instructions
and/or specific problems
3. Repair instructions
and/or specific problems you
you are having with the product.
are having with the product.
model changes, whenever an improvement is possible. This affords
OMEGA ’s policy is to make running changes, not
Our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING. INC.
0 COpyriQht 1994 OMEGA ENGINEERING. INC. All rights reserved. This documentation may not be copied,
copied. reproduced. translated. or reduced to any
eleRronic medium or machine-readable form, in whole or in
without prior written consent of OMEGA ENGINEERING. INC.
photo
pan,
the Controller.. .......................................
1 .I &packing
.................................................
1.2
Controller Description
......................................................
1.3
Keypad Description
Displays .....................................................
1.4
Front Panel
.......................................
1.5 General Information
Section 2 Installing the Controller
2.1
2.2
...........................................
Mounting the Controller
W iring the Controller.. .................................................
............................
Connect ac Power
2.2.1
............
Making Input Connections
2.2.2
Connections..
Making
Output
..........
2.2.3
Section 3 Calibrating the pH Electrode
3.1
Calibrating the
pH Electrode
........................
pH Controller Operator ’s Manual
..
Operating the Controller
Section 4
4.1
4.2
Entering PHCN-410 Hi/Lo Setpoints
....................................
Setpoint Value ..................................
To Enter the Hi
4.1.1
4.1.2
To Enter the Lo Setpoint Value.. ...............................
Error Messages
..........................................................................
..
4-l
4-l
.4-l
4-2
Section 5 Specifications
Section 5.1 Specifications
......................................................................5-l
1 .l Unpacking the Controller
Remove the Packing List and verify that you have received
equipment. If you have questions about the shipment, plea
the OMEGA Customer Service Department at l-800-622-23
(203) 359-1660.
Upon receipt of shipment, inspect the container and equipm
any signs of damage. Note any evidence of rough handling
transit. Immediately report any damage to the shipping ag
The carrier will not honor
CI& claims unl
shipping material is saved
for their exam
examining and removing contents, save pack
material in the event reshipment is necessary.
ii
Getting Started
1.2 Controller Description
The OMEGA” PHCN-410
pH controller is a microprocessor-based
pH controller with automatic temperature compensation, a 4-digit
LED display, two SPDT mechanical relays, and a fixed 4-20
output.
Figure l-l. Front Panel Display
1-2
1.3 Keypad Description
mA
The PHCN-410 features four keys for entering all set-up
parameters and performing calibration. (Refer to Figure l-l
SElITEMP
Select setpoint reby modes
CAl/ENIER
Initiate calibmtion procedu
buffers 7.00,4.01 or 10.0
setpoint values
4
Select numeticol position fro
A
Select number from
O-9
Installing the Controller
.
1.4 Front Panel Displays
2.1 Mounting the Controller
P”
Controller in
CAL
pH calibration mode; display shows 7.OO,4.01,
and 10.01; CAL annunciator off when calibration
complete
Hi
High alarm relay activated
lo
Low alone relay activated
pH mode
1.5 General Information
Refer to Figures 2-l and 2-2 for panel cutout and meter
dimensions.
&
90 m
We recommend that you bench-test all equipment prior to
installation. This requires wiring the equipment and checking relay
and output functions as well as
pH input (see section 2.2). This is
also a good time to initially calibrate the
pH electrode to the meter
(see section 3).
Figure 2-1. Panel Cutout Dimens
l-4
.
. . . , )
‘
Installing
Installing the Controller
2.2.2 Making Input Connections
1.
2.
Connect the pH combination
bock of the unit.
electrode to the BNC connector on the
If using Automatic Temperoture Compensotion (ATC), connect the
100 ohm Pt RTD leads of the temperature probe to Terminals 1
2 (no polarity - see Figure 2-3).
The 100 ohm Pt RTD temperature probe can be separate from
the pH electrode, built into the body of the
pH electrode or (in
selected models) built into the mounting assembly of the
pH
electrode.
If an ATC input is not provided to the meter, the temperature
reading will default to 25°C. If the process temperature is constant,
but not 25”C, a precision resistor can be used to simulate the
appropriate temperature value to the unit. For example, if the
O”C, a resistor with a value of 100 ohms can
control process runs at
be wired to Terminals 1 and 2. The temperature display will show
approximately 0°C. For a complete temperature versus resistance
table, consult the OMEGA Temperature Measurement Handbook
and Encyclopediam.
2-4
ond
The PHCN-410
Compensotion;
displayed.
features Automatic Temp
however, the temperature
2.2.3 Making Output Connections
For Hi and Lo
Setpoint
Relays:
Connect the proper load to the NO and COM
and COM terminals.
When the load is connected to the NO and COM, the re
open until the
setpoint is reached. When the load
to the NC and COM, the relay is closed until the
reached. The wiring configuration is application depend
The PHCN-410 has a fixed 4-20
mA output.
Calibrating the pH Electro
Installing the Controller
Notes
3.1 Calibrating the pH Electrode
Calibration of the electrode to the
pH meter
pH measurement. It is also necessary to recalibrate the
periodically. The frequency of recalibration is system dep
The pH calibration procedure is as follows:
1.
Connect the combinotion pH electrode ond
compensation probe (if using ATC) to the m
Figure 2-3).
2.
Apply power to the instrument.
3.
Remove the electrode protector from the end o
rinse the electrode with distilled woter, and
buffer 7.00 solution. Press the CAL key.
At this time the “CAL”
annunciator light w
light goes off, the first point is calibrated. If “7-E” appea
display, this means the
pH buffer 7.00 was n
electrode has failed.
2-6
Operating the Controller
Calibrating the pH Electrode
4.
Remove the pH electrode from the
pH buffer 7.00. Rinse
the
electrode with distilled water ond place the electrode in stondord
pH buffer 4.01 or 10.01. Press the CAL Key.
At this time the “CAL” annunciator light will appear. When the
light goes off, the slope is calibrated.
4.1 Entering PHCN-410
4.1. 1
To Enter the Hi Setpoint Value:
1.
Press the SET/TEMP
front ponel.
2.
Use the 4 and A keys to change the display
desired value.
3.
When the desired value is showing in the
dis
CAL/ENTER keypod k store this v&e into me
4.1. 2
3-2
Hi/Lo Setpoints
keypad, until the
Hi ann
To Enter the lo Setpoint Value:
1.
Press the SET/TEMP keypod, until the Lo onnu
front panel.
2.
Use the 4 ond A keys to change the
desired value.
3.
When the desired value is showing in the display, p
CAL/ENTER keypod to store this value into mem
displaye
Notes
Notes