Download Lightolier Sidemount Strip SM STRIP User's Manual

Transcript
Sidemount Strip
Page 1 of 2
SM STRIP
4-1/8" WIDE, 1-13/16" DEEP, 24", 36", 48" LENGTHS, 1 OR 2 LAMP, T8 OR T12
Features
•
•
•
•
•
•
•
•
•
•
•
Only 1-13/16" deep.
Efficiency 95.8%..
Ballast cover secured by quarter-turn latches.
Fully enclosed wiring.
May be surface mounted or suspended.
May be continuous row mounted.
Code gauge, heavy duty, die formed steel channel.
Multiple knockouts for convenient installation.
Lampholders may be individually replaced or rewired.
High reflectance baked white enamel finish.
UL Listed for damp locations.
.
Dimensions
"A"
2"
(51mm)
2-1/2"
(66mm)
TOP VIEW
1/2" K.O. (2)
7/8" K.O. (3)
1-13/16"
(46mm)
1-1/16" (27mm)
1-1/16" (27mm)
SIDE VIEW
7/8" K.O. (4)
1-1/4"
(32mm)
3-3/4"
(95mm)
1-13/16"
(46mm)
4-1/8"
(105mm)
ONE LAMP
1-13/16"
(46mm)
5-11/16"
(145mm)
TWO LAMP
Job Information
Type:
Job Name:
Cat. No.:
DIMENSIONS
Lamp(s):
“A”
Channel Length
Inches
(mm)
2' Channel
24"
(610 mm)
3' Channel
36"
(914 mm)
4' Channel
48"
(1219 mm)
Volts/Ballast:
Lightolier a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 3A/Folio H120-15
Sidemount Strip
4-1/8" WIDE, 1-13/16" DEEP, 24", 36", 48" LENGTHS, 1 OR 2 LAMP, T8 OR T12
PHOTOMETRY
REPORT NO.:
CATALOG NO.:
LAMP(S):
EFFICIENCY;
LUMINAIRE:
WATTS:
MODEL NO. SM234HPF120LE
G14162
SM234HPF120LE
2 F40 , EACH RATED 3150 LUMENS
95.8%
SIDE MOUNTED STRIP, MAGNETIC
82.0
CANDELA DISTRIBUTION
0.0
45.0
00
819
819
05
815
814
15
787
785
25
731
741
35
650
673
45
545
586
55
422
492
65
286
400
75
150
323
85
41
288
95
42
276
ZONAL LUMEN SUMMARY
ZONE
LUMENS
00-030
641
00-040
1061
00-060
1954
00-090
2971
90-180
3061
00-180
6033
DATE.: 8/14/91
FLUX
90.0
819
812
791
752
694
628
561
497
462
443
428
1-13/16"
(46mm)
77
222
341
420
452
440
392
334
291
284
%LAMP
10.2
16.8
31.0
47.2
48.6
95.8
%FIXT
10.6
17.6
32.4
49.3
50.7
100.0
LUMINANCE DATA IN CANDELA/SQ M
ANGLE
AVERAGE
AVERAGE
IN DEG
0-DEG
45-DEG
45
4703
3870
55
4400
3589
65
3916
3373
75
3129
3348
85
1918
4031
AVERAGE
90-DEG
3855
3730
3728
4118
5055
5-11/16"
(145mm)
TWO LAMP
LER = FS - 69.9 Watts - 82 BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $3.43
coefficients of utilization — zonal cavity method
RF
20
20
RC
80
50
RW
70
50
30
50
30
1
92
87
82
67
64
2
83
75
68
57
53
3
75
65
57
50
45
4
68
57
49
44
39
5
63
51
42
39
34
6
58
45
37
35
30
7
53
41
33
32
26
8
49
37
29
29
23
9
46
34
26
27
21
10
43
31
24
24
19
room cavity ratio
Page 2 of 2
SM STRIP
10
61
49
41
34
29
25
22
19
17
16
50
55
47
41
36
32
29
26
24
22
20
20
30
30
53
44
37
32
28
25
22
20
18
16
10
51
41
34
29
25
21
19
17
15
13
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD
PERFORMANCE MAY DIFFER FROM LABORATORY PEFORMANCE.
ORDERING INFORMATION
Explanation of Catalog Number. Example: SM234HPF120LEGLR
SM
SIDEMOUNT
STRIP
BALLAST TYPE:
LPF=Low Power
Factor
HPF=High Power
Factor
LAMP
QUANTITY:
1 or 2 Lamp
LAMP:
(By Others)
17=(T8), 2' Length
20=T12, 2' Length
25=T8, 3' Length
30=T12, 3' Length
32=T8, 4' Length
34=T12, 4' Length
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate
suffix to catalog
no., ie: (GLR)
BALLAST:
1 or 2 Lamp Mag. (T12) LE
Standard Electro Magnetic
P
(20 or 30 watts only)
<20THD <10THD
1 or 2 Lamp Elec. (T8) SO*
HI*
LOL Dimming (T8)
PS
–
*Instant Start Standard
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES
SPECIFICATIONS:
FUSING: Internal fast-blow fusing.
SUFFIX: GLR.
Internal slow-blow fusing.
SUFFIX: GMF.
ELECTRICAL/WIRING OPTIONS: Consult factory.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz.
One per fixture. SUFFIX: RF.
STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.
Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"),
ASC24 CSP (24").
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel, 113/16" deep x 2-1/2" channel width.
BALLAST: Cover–code gauge cold rolled steel, secured by quarter-turn
latches.
FINISH: Chassis exterior–baked white polyester
enamel, minimum reflectance 86%.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and ULc Listed.
Job Information
Type:
Lightolier a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 3A/Folio H120-15