Download Cooper Lighting Metalux AB Arctic Bay Series User's Manual
Transcript
COOPER LIGHTING - METALUX DESCRIPTION The Arctic Bay Series is designed as a high efficiency solution to sub-zero ambient environments found in cold storage and refrigerated facilities. The Arctic Bay has been optimized to provide maximum performance with lamp and ballast systems that tolerate colder ambient temperatures. For legislative compliance and additional energy savings, an optional low temperature motion sensor is available. ® Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES APPLICATION The Arctic Bay Series high lumen package allows for the benefits of fluorescent lighting to be applied at high mounting heights that were traditionally exclusive to H.I.D. These benefits include exceptional color rendering, high system efficacy, 95% lumen maintenance, long lamp life, instant on, optional dimming, and uniform brightness control. Primary applications include cold storage, refrigerated facilities and environments with temperatures as low as -29°C (-20°F). A ... Construction Housing, end plates and socket tracks are die formed cold rolled steel. The housing features an integral ballast channel that adds strength and provides numerous KO's for easy installation. Die formed internal reflectors are available in either a high reflectance specular material or a painted white polyester powder coat finish. A sealed and gasketed aluminum door frame in a clear or prismatic A12 pattern lens provide for a thermal environment for optimal lamp operation. B ... Electrical Class P ballast, rated for -29°C to 90°C operation, wired to rotor locked sockets. Optional passive infra-red motion sensor is rated for high humidity, low temperature application. Sensor provides 1400 sq. ft. of coverage in mounting heights up to 40'. MS/OB option keeps two inner lamps illuminated full time using outer lamps for occupancy control. MS/AO option relay rotates on/off cycle between 2 lamp and 4 lamp ballasts to minimize lamp degradation. UL/CUL listed. Suitable for damp location. B A C C ... .Post Fabrication Electrostatically applied baked white polyester powder coat finish is preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor. D ... Optics Gasketed door frame and lens assembly is standard for subzero ambient environments. E ... Mounting The fixture is ideally suited for surface, suspension mounting with optional wire hook and chain set, stem or cable mounting. Top connector box mounting is also available. AB ARCTIC BAY SERIES 15" x 4', 2' x 4' High-Bay 4 and 6 Lamp HIGH-BAY INDUSTRIAL LUMINAIRE D E 5-1/2" [140mm] 24" [610mm] E N E R G Y D ATA LAMP CONFIGURATIONS DIMENSION TOP VIEW 4-Lamp Access Plate Opening Mounting for Top Connector Box 4-3/4" [121mm] X=2-7/8" [74mm] 11/16" [18mm] K.O. 17/64" Diameter Hole X X X 15-7/16" [392mm] (4-Lamp) or 24" [610mm] (6-Lamp) 15-7/16" [392mm] 6-Lamp X X X X Luminaire Efficacy Rating LER =54 Catalog Number: 2AB-654T5-UNVEBT2-U Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $5.08 * Reference the lamp/ballast data in the Tecnical Section for specific lamp/ballast requirements 5-1/2" [140mm] X=3-1/2" [89mm] Input Watts (@ 277V): EB Ballast 454 = 229W 654 = 346W ** Consult Pre Sales Technical Support. X 24" [610mm] 48" [1219mm] 2-1/4" [58mm] 3-1/2" [89mm] LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADF071257 10/06/2008 2:10:23 PM PHOTOMETRICS AB ARCTIC BAY SERIES 2AB-654T5-UNV-EBTL2-U Electronic Ballasts (6) F54W T5HO lamps 26400 lumens Spacing criterion: (II) 1.1 x mounting height, ( ) 1.2 x mounting height Efficiency 65.1% Test Report: BAL13590.IES LER =FL59 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.06 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 78 69 61 54 48 44 40 36 33 31 29 78 66 57 49 43 38 34 31 28 26 24 78 64 53 45 39 34 30 27 24 22 20 76 70 64 59 54 50 47 43 41 38 36 76 67 59 53 48 43 39 36 33 30 28 Along II 9670 9568 9513 9020 8661 7923 6907 6251 5582 5059 4194 3551 2901 2245 1665 1116 605 233 31 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 76 76 65 63 56 53 48 45 43 39 38 34 34 30 31 27 28 24 25 22 23 20 50% 50 30 10 30% 50 30 10 50 72 64 57 51 46 42 38 35 32 30 28 69 62 55 49 44 40 37 34 31 29 27 66 60 53 48 43 39 36 33 30 28 26 72 63 54 47 42 37 33 30 27 25 23 72 61 51 44 38 34 30 27 24 22 20 69 60 52 46 41 36 33 30 27 25 23 69 59 50 43 38 33 30 27 24 22 20 Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp %Fixture 6856 10426 16414 19532 19532 22.9 34.8 54.7 65.1 65.1 35.1 53.4 84.0 100.0 100.0 75 67 61 55 49 44 40 37 33 30 28 75 65 57 50 45 39 35 32 28 25 23 75 63 54 47 41 36 32 28 25 22 20 73 68 63 59 54 50 47 43 40 37 35 Average 45-Deg cd/sm 10163 8282 6770 5372 3600 Candela (2) Electronic Ballasts (4) F54W T5HO lamps 26400 lumens Spacing criterion: (II) 1.1 x mounting height, ( ) 1.0 x mounting height Efficiency 62.8% Test Report: 14005 LER =FL58 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.13 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 75 70 65 60 56 51 48 44 41 38 36 Average 0-Deg cd/sm 11513 9962 8548 6939 4302 AB-454T5-CL-UNVEBTL1-U C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 73 66 59 54 48 44 40 36 33 30 27 73 64 56 50 44 39 35 32 28 25 23 Across 9670 9524 9324 8718 8137 7197 5917 5059 4188 3538 2863 2384 1968 1545 1192 845 504 233 63 20% Zonal Lumen Summary Lumens 45° 9670 9543 9400 8844 8377 7588 6497 5809 5071 4466 3614 2952 2352 1778 1305 864 473 195 50 2AB-654T5-CL-UNVEBTL2-U Candela Electronic Ballasts (6) F54W T5HO lamps 26400 lumens Spacing criterion: (II) 1.1 x mounting height, ( ) 1.2 x mounting height Efficiency 69.5% Test Report: LM-63-2002 LER =FL63 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.81 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 78 71 66 60 56 51 48 45 42 39 37 Candela 73 62 53 46 41 35 32 28 25 22 20 Along II 5741 5782 5778 5547 5531 5186 4798 4329 3989 3099 3120 2560 1999 1461 949 495 178 32 0 30% 50 30 10 50 70 63 57 52 47 42 39 35 32 29 27 67 61 55 50 46 41 38 34 31 29 26 64 59 53 49 44 40 37 34 31 29 26 70 62 55 48 43 38 34 31 28 25 23 70 60 52 46 40 35 31 28 25 22 20 67 60 53 47 42 38 34 31 28 25 22 67 59 51 45 40 35 31 28 25 22 20 Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Fixture 4324 6484 9542 11049 11049 24.6 36.8 54.2 62.8 62.8 39.1 58.7 86.4 100.0 100.0 66 57 49 42 37 33 29 26 24 22 20 65 56 48 41 36 32 28 25 23 21 19 Average 90-Deg cd/sm 8051 6688 5883 5254 4302 45° 5741 5745 5649 5390 5385 4959 4301 3428 2711 1720 1595 1282 1035 851 733 452 183 26 0 50% 50 30 10 Luminance Data %Lamp 66 58 51 45 40 36 32 29 27 25 23 0% 0 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 83 76 70 64 59 55 51 47 44 42 39 83 73 65 58 52 47 42 39 35 33 30 83 71 60 52 46 41 36 33 30 27 25 83 68 57 48 42 36 32 29 26 24 22 81 75 68 63 58 53 50 46 43 41 38 81 72 64 57 51 46 42 38 35 32 30 81 69 60 52 45 40 36 33 30 27 25 81 67 56 48 41 36 32 29 26 24 21 50% 50 30 10 30% 50 30 10 50 77 69 61 55 49 44 40 37 34 31 29 74 66 59 53 47 43 39 36 33 31 29 71 64 57 51 46 42 38 35 32 30 28 77 67 58 50 44 39 35 32 29 27 25 77 65 55 47 41 36 32 28 26 23 21 74 65 56 49 43 39 35 32 29 26 24 74 63 54 46 40 35 32 28 26 23 21 Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp %Fixture 6390 9871 15445 18344 18344 24.2 37.4 58.5 69.5 69.5 34.8 53.8 84.2 100.0 100.0 Across 8130 8289 8398 8179 7685 6844 5568 4145 3469 3096 2708 2344 2089 1928 1760 1077 501 106 0 20% Zonal Lumen Summary Lumens 45° 8130 8204 8279 8200 7895 7423 6751 5832 4601 3415 2812 2371 1925 1545 1251 1031 487 108 0 Average 0-Deg cd/sm 11454 10336 8384 5135 1187 Average 45-Deg cd/sm 7569 6478 5729 6243 1942 10% 30 10 71 62 55 48 43 38 34 31 28 26 24 71 61 52 45 40 35 31 28 25 23 21 0% 0 69 60 51 44 38 34 30 27 24 22 20 Average 90-Deg cd/sm 6862 6404 7149 6521 1906 Across 5741 5670 5407 8718 5110 4312 3272 2463 1973 1466 1487 1309 1256 1148 792 463 102 21 0 20% Zonal Lumen Summary Lumens 10% 30 10 Along II 8130 8092 7982 7798 7538 7204 6794 6317 5776 5168 4500 3783 3030 2261 1517 848 335 66 0 Average 0-Deg cd/sm 11064 11265 8725 4832 917 Average 45-Deg cd/sm 6138 5642 5082 4411 765 10% 30 10 64 58 52 46 41 37 33 30 27 24 22 64 57 50 44 39 34 31 28 25 22 20 0% 0 63 56 49 43 38 33 30 26 23 21 19 Average 90-Deg cd/sm 5233 5762 6854 4514 612 Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADF071257 10/06/2008 2:10:23 PM Thermal Performance Cooper Lighting thermally tested each configuration to determine the optimal luminaire operating temperature range. When specifying luminaires use the lowest temperature the luminaire will be exposed to during operating hours. However, facility temperatures fluctuate and luminaires exposed to temperatures less than stated are not recommended. Freezer Temperature Ranges To maximize energy efficiency, some facilities will operate chillers only during off-peak 40 ft. hours. in this case the facility will chill the space -40°F (-40°C) to maintain the targeted temperature during operating hours. Fluorescent luminaires exposed to -40°F (-40°C) 35 ft. @ -40°F (-40°C) temperatures are not recommended. Energy efficient HID sources may be a better 30 ft. alternative. 20 ft. 20 ft. @ -20°F (-29°C) 10 ft. 10 ft. @ -10°F (-23°C) Temperature Control Capability Cooper Lighting recommends the following lamp operation when implementing a control system in colder ambient environments. Arctic Bay (AB) Series Motion Sensor Options (Number of Lamps Controlled) -20°F (-29°C) Fixture # Lamps Lamp Type Routine Use Occasional Use (3) AB-454T5 4 Lamp T5HO Not Recommended 2 2AB-654T5 6 Lamp T5HO Not Recommended 2 Fixture # Lamps Lamp Type Routine Use (1) Occasional Use (2) AB-454T5 4 Lamp T5HO 2 ALL 2AB-654T5 6 Lamp T5HO 2 4 Motion Sensor Options (Number of Lamps Controlled) 0°F (-18°C) Motion Sensor Options (Number of Lamps Controlled) 32°F (0°C) – 50°F (10°C) Lamp Type Routine Use (1) Occasional Use (2) 4 Lamp T5HO 2 ALL 6 Lamp T5HO 2 Fixture # Lamps AB-454T5 2AB-654T5 4 (1) Luminaire NOTES: achieves 40% or greater of relative light output at the indicated temperature in under 60 seconds. 80% of relative light output at the indicated temperature in under 7 minutes. (3) Consult factory. (2) Luminaire achieves 40% to ORDERING INFORMATION S A M P L E N U M B E R : 2AB-654T5-UNV-EBT2-MS/OB-U Shielding Blank=Prismatic Acrylic Lens w/Gasketed Doorframe CL=Clear Acrylic Lens w/Gasketed Doorframe Width Blank=15" 2=24" Series AB=Arctic Bay Voltage (2) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (T5 linear only) 120V=120 Volt 277V=277 Volt 347V=347 Volt Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No. of Lamps 4=4 Lamps (AB) 6=6 Lamps (2AB) Lamp Type 54T5=T5HO Lamps (48") Distribution Blank=Medium (Specular Aluminum) G=Wide (White Painted) (1) Options Lamps Installed L5835=T5 Lamp, 80CRI 3500K L5841=T5 Lamp, 80CRI 4100K L5850=T5 Lamp, 80CRI 5000K GL=Single Element Fuse GM=Double Element Fuse Emergency=Please Consult Factory (2) Ballast Type EBTL =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% Minimum Start Temp. -20˚F (-29˚C) No. of Ballast 1, 2 or 3 DIM=Consult Factory (6) Options(6) C3=3' White Cord Fixture Attached C6=6' White Cord Fixture Attached MS=Aisle Coverage Motion Sensor (3) MSO=360˚ Coverage Motion Sensor (3) MS/OB=Aisle Modular Sensor Wired with Inner Two Lamps Constant On (3) MSO/OB=360˚ Modular Sensor Wired with Inner Two Lamps Constant On (3) MS/AO=Aisle Motion Sensor/Alternate Off (Alternate Ballast Relay)(3), (4) MSO/AO=360˚ Motion Sensor/Alternate Off (Alternate Ballast Relay)(3), (4) PC3-Voltage=3' Cord/Plug Fixture Attached(2) PC6-Voltage=6' Cord/Plug Fixture Attached(2) TCBP=Top Connector Box Plate Packaging U=Unit Pack PAL=Palletized Out of Carton PALC=Job Pack In Carton Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (7) RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop HB-SPS=Single Point Cable Kit (13" Drop Length) Gripple Y-=Y Mounting Toggle, #2 Cable (Specify 10' or 30') TCB=Top Connector Box SCA-48=Stem Set Adjustable 48" length SCF-=Stem Set Fixed (specify length) SCS=Stem Set 45˚ Swivel (specify length) SHIPPING INFORMATION (2) NOTES: Requires use of voltage specific modular cord assembly. See accessories. Voltage must be specified when ordered with plugs, motion or emergency (3) (4) (5) (6) ballasts. Specify voltage. Requires (2) ballasts. Not available in 480V. Dimming ballasts not recommended for use at temperature < 0°F (-18°C). Refer to (7) Temperature Control Capability chart for recommended sensor options at various cold ambient environments. Not for use in high abuse applications such as gymnasiums. Catalog No. AB-454-UNV-U 2AB-654-UNV-U Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 Wt. 25 lbs. 27 lbs. ADF071257 10/06/2008 2:10:23 PM