Download American Standard Princeton T508.50X User's Manual
Transcript
Installation Instructions PRINCETON T508.50X PRESSURE BALANCING BATH AND SHOWER TRIM KITS Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-- please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1 Required Tools Phillips Screwdriver Adjustable Wrench Plumbers’ Putty or Caulking Channel Locks Flat Blade Screwdriver ROUGHING-IN DIMENSIONS (For reference only) To assure proper positioning in relation to wall, note roughing-in dimensions. 1-5/8" TO 3-1/4" FINISHED WALL SHR. 1/2" NOM. COPPER SWEAT 1/2" NPT INLETS 4-1/16" INLETS 1/2" NOM. COPPER SWEAT SWEAT INLETS 2" 3-5/8" REF. 4-1/16" TUB 1/2" NOM. COPPER SWEAT 5-1/2" REF. OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65’’ AND 78’ SWEAT INLETS (STOPS) 5-7/8" SHR. 1/2" NOM. COPPER SWEAT "SEE ILLUSTRATION " 4-1/16" TUB 1/2" NOM. COPPER SWEAT 74" FOR HEAD CLEARANCE INLETS 1/2" NOM. COPPER SWEAT 6-3/4" OUTLETS 1/2" NPT INLETS 1/2" NPT 5-7/8" 3-3/8" 18" OPTIONAL 3-5/8" INLETS 1/2" NPT 3-3/8" 1/2" NPT’’ 4" 3-3/8" OUTLETS 1/2" NPT 5-1/8" REF. TOP OF TUB RIM BOTTOM OF TUB THREADED INLETS THREADED INLETS (STOPS) CARE INSTRUCTIONS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. INSTALL TRIM 3 When finished tiling the wall, remove PLASTER GUARD (3). Push on CAP (1). 4 Mount ESCUTCHEON (2) and with SCREWS (7). 5 Install HANDLE (8) by pushing it onto CARTRIDGE STEM (9) and tightening SET SCREW (10) from below with 2.5mm Hex Wrench supplied. Insert INDEX BUTTON (11). Remove cap from tub supply and plug from shower pipe. 2 9 Install SHOWER ARM with FLANGE (4) and SHOWER HEAD (5). 1 Install DIVERTER SPOUT (6). For threaded inlets; 1/2" female NPT spout. 7 8 10 11 6 ADJUST HOT LIMIT STOP HOT LIMIT SAFETY STOP ADJUSTMENT By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP. Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0". "A" "A" "B" ADJUSTMENT WHEN WATER IS TOO HOT PRY RED RING FORWARD AND ROTATE COUNTER-CLOCKWISE ONE CLICK ADJUSTMENT WHEN WATER IS TOO COLD PRY RED RING FORWARD AND ROTATE CLOCKWISE "B" 1 SERVICE 1 If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force. Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then: Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets and MANIFOLD (5). Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). Replace CAP (2) and HANDLE (1). Check flow. 2 4 3 5 M968841 PRINCETON PRESSURE BALANCE BATH/SHOWER MODEL NUMBER T508.50X 060351-YYY0A SHOWER ARM AND FLANGE M953530-YYY0A SHOWER HEAD 078016-YYY0A ESCUTCHEON SCREWS M907050-YYY0A ESCUTCHEON CAP SET M962408-YYY0A LEVER HANDLE KIT M962367-YYY0A ESCUTCHEON AND SCREWS M953235-YYY0A DIVERTER SPOUT (IPS) Replace the "YYY" with appropriate finish code CHROME SATIN 002 295 HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 Weekdays 8:00 a.m. to 8:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of American Standard Inc. ' American Standard Inc. 2005 M968841