Download American Standard 2071 User's Manual

Transcript
Installation
Instructions
THE
COLLECTION
by
™
MONOBLOCK
LAVATORY FAUCET
WITH CROSS HANDLE
2071
2071S
Thank you for selecting American-Standard...the benchmark of fine
quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these
instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
M968290A
TOOLS REQUIRED
Channel Locks
Adjustable Wrench
DO NOT:
Do not use any abrasive cleaners, cloths, or
paper towels.
Do not use any cleaning agents containing
acids, polish abrasives, or harsh cleaners or
soaps.
Regular and routine cleaning will reduce the need for
heavy cleaning and polishing. If heavy cleaning is
INSTALL FAUCET
CAUTION
Phillips Screwdriver
Remove as much surface dirt and film using clear
water and soft cotton cloth (as described above).
Use any of the following to remove tough surface
film and build-up:
Mild liquid detergents
Clear ammonia free liquid glass cleaners
Non-acidic, non-abrasive gentle liquid or fully
dissolved powder cleansers mixed according to
manufacturers directions.
Non-abrasive liquid polishers
Once clean, rinse faucet again with clear water to
thoroughly remove cleaner or polish and blot dry with
a soft cotton cloth.
Failure to follow these care instructions may
damage the Faucet's finish.
CARE INSTRUCTIONS:
To keep your new faucet looking new, please follow
these simple care instructions:
DO:
Simply rinse the faucet clean with clear water.
Dry the faucet with a soft cotton cloth.
1
Plumbers' Putty or Caulking
Turn off water at
main supply.
INSTALLATION OPTIONS; Faucet may be installed with ESCUTCHEON
PLATE (1) or for center hole only with ESCUTCHEON RING (2).
INSTALLATION with ESCUTCHEON PLATE (1)
No sealant is required unless mounting surface is uneven for 3-hole
(4" centers) installation with ESCUTCHEON PLATE (1). Place ESCUTCHEON
PLATE (1) over mounting holes on lavatory sink or mounting surface.
Feed FLEXIBLE FAUCET HOSES (3) and MOUNTING STUD (4) through
hole in ESCUTCHEON PLATE (1). Seat ESCUTCHEON PLATE (1) boss
into groove in Faucet base.
From below, install MOUNTING GASKET with
RETAINING WASHER (5) and Nut (6) onto
STUD (4). Pull Faucet to front of sink, so STUD BOSS
(4) rests against sink hole. Before final tightening,
align Faucet and ESCUTCHEON (1) so they are
centered on mounting surface. Tighten NUT (6)
to secure Faucet
Insert LIFT ROD (7).
Feed FLEXIBLE FAUCET HOSES (3) and MOUNTING
STUD (4) through hole in ESCUTCHEON RING (2).
Seat ESCUTCHEON RING (2) boss into groove in
Faucet base.
From below, install MOUNTING GASKET with
RETAINING WASHER (5) and Nut (6) onto
STUD (4). Pull Faucet to front of sink, so STUD
(4) rests against sink hole. Before final tightening,
align Faucet and ESCUTCHEON (1) so they are
centered on mounting surface. Tighten NUT (6)
to secure Faucet
Insert LIFT ROD (7).
GROOVE IN
FAUCET BASE
BOSS
1
4
2
GROOVE IN
ESCUTCHEON
RING BASE
INSTALLATION with ESCUTCHEON RING (2)
For single hole installation use ESCUTCHEON
RING (2). Install SEAL WASHER (6) into groove
in ESCUTCHEON RING (2) base and place over
over mounting hole in lavatory sink or mounting
surface.
7
6
LAVATORY SINK
OR MOUNTING
SURFACE
3
5
6
2
INSTALL POP-UP DRAIN
Push Tail piece (11) down into Trap (C) (threaded end up).
Thread Locknut (5), Washer (4) and Gasket (3) (Bevel side
up) onto Drain Body (10).
Apply a bead of Putty (D) to underside of Flange (2).
Feed Drain Body (10) up through Sink (A) and thread the
Flange (2) or (2A) fully onto Drain Body (10).
Tighten Locknut (5) firmly, keeping the pivot rod hole pointed
towards the back of the sink.
Assemble Pivot Rod (9) as shown in Figure-3A. Notice
the position of the Concave Washer (G).
1
2
D
A
E
3
6
Insert Pivot Rod (9) into Drain Body (10) and tighten
Pivot Nut (F).
4
7
Push TAILPIECE INSERT (12) into TAILPIECE (11) and push
TAILPIECE up and thread tightly into DRAIN BODY (10).
Position Extension Rod (7) onto Pop-Up Rod (E) and tighten
Thumbscrew (6).
Remove one end of Clip (8) from Pivot Rod (9) by squeezing
ends together while sliding.
Insert Pivot Rod (9) or (9A) into second or third hole in Extension
Rod (7) and reassemble Clip (8).
5
7
8
F
10
12
9
C
11
1-1/4"
Drop Stopper (1) into Drain Body (10).
Adjust stopper height by repositioning Extension Rod (7) and
tightening Thumbscrew (6).
9
F
G
O-RING
FIGURE-3A:
3
WATER SUPPLY CONNECTIONS
Note: FLEXIBLE HOSES (1, 2) on FAUCET (3) are (17-1/2") in
length from base of faucet. If longer supply length is required
installer must purchase adapters and additional supplies to
complete connections.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking .
3
Connection on FLEXIBLE HOSES (1, 2) are 3/8" compression.
Connect LEFT SUPPLY (1) to Hot shut off valve and RIGHT
SUPPLY (2) to Cold shut off valve.
Use adjustable wrenches to tighten connections. Do not
over tighten.
(17-1/2")
1
COLD
2
3/8" compression
HOT
SHUT OFF
VALVE
M968290A
4
TEST INSTALLED FAUCET
AND CHECK FOR LEAKS
1
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
3
Operate HANDLE (1) to flush water lines thoroughly.
4
Replace AERATOR (3).
6
5
4a
CHECK DRAIN CONNECTIONS
Operate LIFT ROD (4) and fill lavatory with water. Check that
DRAIN STOPPER (5) makes a good seal and retains water in
lavatory. If necessary adjust stopper height by repositioning
LIFT ROD (4) and tightening Thumbscrew (6).
"P" TRAP
Release DRAIN STOPPER (5) and check all drain connections
and "P" trap for leaks. Tighten if necessary.
COLD
2
HOT
5
ADJUST HOT LIMIT STOP
1
2
By restricting HANDLE rotation and limiting the amount of hot water
allowed to mix with the cold, the HOT LIMIT SAFETY STOP (5) reduces
risk of accidental scalding. To set the maximum hot water temperature
of your faucet, all you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP (5).
3
Remove INDEX BUTTON (1), HANDLE SCREW (2) and pull off HANDLE (3).
5
Turn CARTRIDGE STEM (4) to the OFF position (coldest setting) before
making adjustment to HOT LIMIT STOP (5). Use a flat blade screwdriver
to pry free the HOT LIMIT SAFETY STOP (5). Pull upward and rotate
counterclockwise one number to limit hot water temperature. Use
ARROW (6) on CARTRIDGE (7) and NUMBERS (8) on HOT LIMIT STOP (5)
for indication.
1
5
13
119
7531
Replace HANDLE (3), HANDLE SCREW (2) and INDEX BUTTON (1).
1
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
1
6
5
13
11
97531
5
8
COLDER
(Larger Numbers)
4
0 1 3 5 7 9 11 13 15
1
51
311 7531
9
0
5
1
7
4
M968290A
FLAT BLADE
SCREWDRIVER
6
5
5
13
11
9753 1
M962237-0070A
INDEX BUTTON
A918657-0070A
HANDLE SCREW
THE
COLLECTION
™
by
M962236-YYY0A
HANDLE
MONOBLOCK
LAVATORY FAUCET
WITH CROSS HANDLE
M914423-YYY0A
METAL RING
MODEL NUMBER
A912706-0070A
O-RING
2071
2071S
918633-0070A
CARTRIDGE SCREWS
Replace the "YYY" with
appropriate finish code
A923611-0070A
HOT LIMIT STOP
CHROME
SATIN
002
295
A954400-0070A
CARTRIDGE KIT
072574-0070A
EXTENSION ROD
M962242-YYY0A
KNOB & ROD
066116-YYY0A
DRAIN STOPPER
066117-YYY0A
FLANGE KIT
FLANGE
066070-YYY0A
AERATOR
M962238-YYY0A
ESCUTCHEON KIT
(THREE HOLE)
GASKET
953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070847-0070A
CLIP
WASHER
LOCKNUT
M962239-YYY0A
ESCUTCHEON KIT
(SINGLE HOLE)
051049-0070A
MOUNTING KIT
3
066118-0070A
PIVOT ROD
M961711-0070A
TAILPIECE INSERT
070532-0040A
TAILPIECE
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2003
M968290A