Download Aiphone TD1-H User's Manual

Transcript
on E» AIPHONE
4 TD-H Series В
SELECTIVE CALL INTERCOM
TD-1H/B (1-call)
TD-3H/B (3-call)
Models: TD-6H/B (6-call)
TD-12H/B (12-call)
\_ TD-24H/B (24-call) J
INSTALLATION & OPERATION MANUAL
CONTENTS
1 SYSTEM OUTLINE & COMPONENT S......………rrsccrererecrrecrarenanenrererennanaranenenr eme a ner e nana aan eee eee 1
2 NAMES 8 FEATURES ................eeivesmeniiiirireeneeeeee.. PT TT 2
3 PRECAUTIONS ON INSTALLATION 8 WIRING..................eeeeeeerescnnancine reee RI RI RI II DR eee re 3
4 WIRING.......crarerisreecrnesrenrssaaane aa sans ane mere cree eee eee eee eee etat ee tete te cee rene rene na cena area nan n annee nana 4-9
5 MOUNTINGerreeererr er EEE RRKEERRERRARRRKEKERRERRKRARKEERERREREEEEERERRRRLEKEKRARUEREARERERRERRREKEREERREEEEERERERTERKERKRREREEREER 10
6 OPERATIONS ON TDAH... eee eemiieeeerrr recen ceaee ec enenerere creta reaeee cerrenereearrrene eee ree necerrreees 11
7 CLEANING THE EQUIPMENT e ee eee eee eee seen er enna eeeeeenee aan, 12
8 TECHNICAL PRECAUTIONS coir e eee eee eee eee e eee ease e eee een, 12
ES =10 [07 0) <A D 12
SYSTEM OUTLINE & COMPONENTS
Ш System outline
TD-H/B is a multi-channel selective-call intercom. On loop-wiring, five TD-H station models,
intermixable, can be configured to all-master, master-selective system or mixed. Additionally, using a
potential station(s), PanTilt MY and/or audio IE/IF door stations (2 max.) and paging zone(s) may be
incorporated.
All-master network Master-selective network
TD-1H/B's H Package contents
* TD-H phone station
À . ADT ES и | e Packet of screws
| NENA 5 * Installation & Operation Manual
=
<=
Na ema, 1
E <
-
=
- =
- a 4
14 uu" mtd
TD-12H/B,
TD-24H/B,
etc.
Intermixed network
=== Communication
== Cable
EN Components available
e Intercom master stations: Intermixable PS-12A or
TD-1H/B TD-3H/B TD-6H/B TD-12H/B TD-24H/B PS-12C
6-call
1-call sub 24-call Power supply
TDW-1~24/A Terminal box with 1.5m, 5 feet cord for connecting TD-nH for desktop use,
or surface wall mounting.
— 1 —
Hl Optional accessories
DE-UR IF-DA MY-DC/A MY-CU PD-2 RY-AC/A
Door station Door station PanTilt video Paging adaptor Call extension
adapter relay
[Tm fem
| | «>>
* |E/IF Series * MY Series *e MYH-CU
IE-JA, 1E-NC, MY-DG/A, MY-EA Sub-monitor no talkback
[E-DC, etc. MY-FA, MY-CA,
etc.
NAMES & FEATURES
EH Names 8 functions Ш Features
Wall cradle
Fill in directory
| 3,9 Station-select
4—— 4,10
5, 11
NN 6,12
> CALL
Piezo-speaker
for call tone —
/
CALL À to select
and ring A1-A12
stations
Press on bottom edge
of cover
TD-24H/B
M Handset cradle
Reversely attach wall-mount cradle for desk use.
Wall-mount N
cradle
HE Cable clamp
Two cable clamps (parts) are included on every TD-nH
chassis. See page 10.
Hl Directory card
For TD-24H/B, fill in names on 2 lines, aligning with the
right sample.
*
Intercom communication among 25 stations
(max.) in all-master configuration.
Single-master system, with TD-1H/B
station, or intermixed.
system
* * * *
system)
talkback)
Intermixable five TD-H station models in a
Multiple talk paths for intercom (and paging)
Station-select break-in call
Max. 28 conductor cable, station to station
PanTilt video or audio door station (2 per
Incorporates a zone(s) for paging (with
Call extension buzzer or light
AIPHONE TD-24H
President |
A Conf. 1 | A
7
Reception |
A Conf.2 | A
2 Le
|
A | A
В
3 | | ) 9
7
|
А | А
af | Г
|
|
A
SU
A
‘[
ALL A
CALL
|
e
|
PRECAUTIONS ON INSTALLATION & WIRING
/N CAUTION
% Do not connect any terminal on any unit to AC power lines to prevent fire or unit damage.
* Do not install more than one power supplies PS-12A (or PS-12C) for an entire TD-H system,
including adaptors for door station and/or paging.
x Do not attempt to install or connect wires on TD-H equipment while system's power supply is
plugged in.
x TD-H masters and related equipment, except door station, are designed for indoor use only. Do not
install outdoors. |
% Do not connect any other power source than specified on terminals +, —. Doing so can damage the
TD-H equipment. |
IMPORTANT
Xx For system's installation, there is no need to disassemble the equipment. Do not open any TD-H
system components unless properly qualified.
x Any other manufacturer's products installed with this system (power supply, external signalling device,
etc.) are not covered under Aiphone’s warranty.
Xx Do not mount TD-H equipment in the following places, as it may cause the system to malfunction:
* High or extreme cold temperature areas: under direct sunlight, near equipment that varies in
temperature, in front of air-conditioner, inside a refrigerated area, etc.
* Places subject to moisture or humidity extremes.
* Places subject to environmental conditions, such as dust, oil, chemicals, etc.
x TD-H is an electrical device, which must not be subjected to water, or any other liquid.
* Weather conditions, such as lightning storms, may cause damage to TD-H equipment. We
recommend that power surge protection be installed as follows: (However, this does not guarantee
that no damage will occur).
* When using a power supply
. INTERCOM
that has no GROUND terminal, or ADAPTOR
install a surge arrester near the | FT
output as shown.
C power 7 + | DC 12V
DCp
Surge-arrester
/ 1 Grounded
Install a surge-arrester —
(discharging voltage:
100~180V)at a point
close to the output,
taken to earth ground.
ww If the power supply has a GROUND terminal, take it to an earth ground. In
this case, a separate surge arrester is not necessary.
E Before actually installing the TD-H system, the contents on pages 4 ~ 10 must be thoroughly read
and understood.
— 3 —
WIRING
Ш All-master system configurations
TD-H is basically designed for making all-master system on looped trunk cable, as per table below;
Models Station capacity Cable required (*)
TD-3H/B 4 stations 7-conductor cable
TD-6H/B 7 stations 10-conductor cable
TD-12H/B 13 stations 16-conductor cable
TD-24H/B 25 stations 28-conductor cable
(*) Includes a conductor for D terminal required for a DE-UR(s)
TD-1 H/B, 1-call sub provides TD-3H/B - 24H/B all-master network with own communication points
(intermixed system).
Hl Cable requirements
Use multiconductor cable (non-twisted), 0.65 ~ 0.8mm dia., 22~ 20AWG, to accommodate maximum
number of intercom stations, and featured audio or PanTilt video door stations ) and/or page to a
zone(s), each of which uses one potential wire.
Ш Terminal - block layout = *Two cable clamp tips are attached on chassis. (See page 10)
rh = 030 | +
akon 2001 +
EEE
[Jo
|| el] ыы
ДИ
)
ol Ekle)
e — © = ©
el
Ta i
| "4 ~ 3 |
TD-1H/B TD-3H/B TDW-3/A TD-6H/B TDW-6/A
a
| =) JL Meaning of terminal symbols
|— . Ö | — |, ) No. 1 ~ 24 are selective station
|0 o: © | 0 0 o) points, providing selective calling
: [115 7 = and communication for master-
©2 13 to-master communication.
5 x 2 C terminal is a call tone signal
a! o: © 7 || receive terminal.
ur Ton Ss Yo: D terminal is a door station call
N tone line.
— | | с +, — terminals are 12V DC
TD-12H/B TDW-12/A TD-24H8 TDW-24/4 Power supply lines.
H Power supply
Entire TD-H intercoms can be powered by a single PS-12A(12C) power supply, and locate it in the
center of the trunk cable. It can also power directly such adaptors as DE-UR, PD-1 & PD-2, which
must be all located within 5m, 16’ distance from PS-12A(12C).
E TD-H single-master system |
TD-6H/B TD-1H/B
TD-3H/B - TD-24H/B makes a single-master network, ми TDW-B/
using TD-1H/B 1-call station to call the master station.
TD-1H/B with CALL button only, is allowed to call
TD-H master station only. |
~ 6 pcs
PS-12A/12C
Ш TD-H all-master system
TD-H all-master system can be made by running parallel conductors from station to station.
No. of conductors required is: 2 common (or 3 with D line) plus number of TD-H stations installed.
As shown, one more TD-H station (the last #) may be added on each own No. button. TD-6H/B
/ TDW-6/A
TD-3H/B TD-6H/B w
1 2 3 4 1 3 4 5 6 7
TD-3H/B
(w/ TDW-3/A)
TD-12H/B
(w/ TDW-12/A)
O
Я
Co [e TET: -
1] | EN En 1 "EN 1 [1]
2 2 2uau- Veau au 242
33H18 3 ЗН 83 H—13-—18 3]
AAA 4 Alaa fal Tab apa
(5 }—5 +15] 5 |5 Н—Н5 5 НБ ННБ НБ НБ
"6—6 6) T6116 6 66—16 66 16
7 ZA 7 7 77
8 81 8 TT 818 8 8 8 H— 8 H— 877 — 81
est 27 — 0 E E 9 94919
он-то 10 -— 0h —ho 10 +— {10 -—+1104— {9 — 10 — 10 10
A 11 HT HA 11 11.
12-12 12—12} [12| 242 mM2H—02-— 2 12
1 |2 | 13; [4] [5 | 7] E El 10 141} 12
[D | D | [D | D D | Dj D D | D | [D | D | [D |
+ + | — + |+ | + + | [+] |+ | [+] + | || + Г + |
— E EA
EA AE SE AA i=
PS-12A/12C
H TD-H all-master system
TD-24H/B
1 2 3 4 5
TD-24H/B (w/ TDW-24/A)
A TT A
CALL | 1 1 Th
о 2 2. 2 2
3] 3 | rl 3 3 | 3]
4 4 4 3 4 4 |
5 5 5 5 5 5
6 6 6 6 6 e
7 7 7 7 7 7
El 8 8 | 8 | 8
9 o 9 9 9
10 10110 10 10: 10
11 1 11 11 11 11
12 12 12 12 12 12
[D] [D] [D] [D] [D] [D] [D] [D] [D]
+ + +] FL 1 +] +] Fu +
SAHARA
CALLA PS-12A AC
A1}— HAT AT AT HAN HAT HAIH-— HA HATH HATH—HATH— {aq} 1126
A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2
A3 A3 A3 A3 A3 A3 A3 АЗ АЗ A3 АЗ АЗ
Ad A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4
AS AS A5, A5 AS A5 A5 AS A5 A5 A5 A5
AB AB. Аб Аб Аб Аб Аб A6 A6 Аб A6 Аб
A7 A7 A7 A7 A7 A7 A7 A7 A7 A7 A7 A7
A8 AS A8 AS A8: AS A8 AS A8 A8 AB АВ
A9 A9 A9 A9 A9 A9 A9 A9 A9 A9 A9 A9
AMO AO A10 MO AD A10 AO Alo АТО) AQ AÑO AÑO
A AÑ AT AÑ AN A AÑ AÑ AÑ AT Alt AN
Aia A2 A2 Ata A2 Aia Aia A2 A2 Ata At2-— 12]
[1] [2] 3] [4] 5] e] [7] 8] 9 [10] 11] [12]
———]— NJ ОЙ nS NY Me 55 Sf NS — KA 7 NF A „”
H TD-H intermixed system TD-6H/B
N
TD-1H/B TD-1H/B TD-1H/B J
Intermixed system is an all-master 4 single-
master combined within a system.
Each TD-H master station may have additio-
Cable requirements
Wiring distance
nal contacts with TD-1H/B, 1-call station (s).
TD-1H/B stations can be wired to the TD-6H/B
master station, using unused conductors in
the trunk cable
(w/ TDW-6/A)
|
(ТЕЛЕ ek
Use a multi-conductor (non-twisted)
TD-H Intercoms (any communication)
Diameter 0.65mm
0.8mm
1.0mm
AWG
22AWG
20AWG
18AWG
ME
LT
cable 0.65 - 1.0 mm dia., 22 ~ 18AWG for TD-H intercoms.
Distance 650m
1,000m
1,500m
Distance
2,000’
3,000
4,900’
—6—
E Audio
TD-H system may have one or two audio door
13
A3
AS
Аб
7
А8
Al
11
12
A1
14
TD-24H/B (w/ TDW-24/A)
I |
I ==
A5
A7
A8
1
A11
12
A2
15
A1
A4
AS
A7
A8
A9
1
11
12
A3
23
DZ © © NOS of =. —
5
door station IE/IF series
TD-6H/B
station IE/IF series, using a potential station.
Intermittent tremolo rings at max. 12 TD-H
phones. For 2nd door station, change SW. to
B position on DE-UR, to change call tone faster.
From DE-UR to IF-DA, etc.
TD-6H/B #5
(w/ TDW-6/A)
Diameter 0.65mm 0.8mm 1.0mm
Distance 150m 230m 350m
AWG 22AWG | 20AWG | 18AWG |
Distance 500’ 700’ 1,100 |
From DE-UR to power supply
Diameter 0.65mm 0.8mm 1.0mm AWG 22AWG | 20AWG | 18AWG
Distance 10m 15m 20m Distance 30° 50” 65”
M PanTilt video integration to TD-H
MYH-CU
MYH-CU
СТ
3 common + No. of TD-H
stations/ adaptors installed
TD-6H/B
MY-DC/A
|
When MY-DC/A calls in, TD-6H/B stations
receive an intermittent call tone, with an image
on video-monitors. Pick up and select the
assigned # station to reply.
MYH-CU 1
A1
MYH-CU 2
A2
U2
+
TD-6H/B 1
2 L2 | 2 Fa
3 3 3 3
4 4 4,
5 5 D
6 [6] a te
ER ra 5] 6]
D D] D] 1D]
+) : [+] [+] {+
| :
= | Л = = Le
у к + A7
% Strictly observe that DE-UR
is adjacently installed to the
PS-12A/12C, so as to be : Y |
powered from it. ToEL9S & -</—
AC trans. =/ RE
MY-CU cable requirements & power supply * From DE-UR to power supply
2 conductors (non-twisted) from MY-CU to MY-DC/A. Diameter 0.65mm | 0.8mm | 1.0mm
6 conductors (non-twisted) from MY-CU to MYH-CU sub- Distance 10m 15m 20m
monitors with no extra conductors in the cable. AWG 22AWG | 20AWG | 18AWG
Wiring distance Distance 30’ 50 65’
» From MY-CU to power supply * From MY-CU to PanTilt door MY-DC/A + From MY-CU to MYH-CU #1 (2 monitors)
Diameter 1.0mm Diameter 0.65mm | 0.8mm 1.0mm Diameter 0.65mm | 0.8mm 1.0mm
Distance 5m Distance 50m 65m 100m Distance 35m 50m 75m
AWG 18AWG AWG . 22AWG | 20AWG | 18AWG AWG 22AWG | 20AWG | 18AWG
Distance 16’ Distance . 165 210° 330” Distance 115’ 150° | 250’
* Between TD-H intercoms (any pair) e From MY-CU to MYH-CU #2 (3 monitors)
| Distance 650m | 1,000m | 1,500m Distance 20m 30m som
; AWG 22AWG | 20AWG | 18AWG AWG 22AWG | 20AWG | 18AWG
| . , 3 ,
| Distance 2,000” | 3,000” | 4,900 Distance 65 100 150
E Paging adaptors PD-1 and PD-2
/
100V or 70.7V line
Paging SP
Paging SP
Talkback SP
1
* PD-1 paging adaptor
Paging speakers
—_— =
PD-1 or PD-2 controls each paging zone,
using an amp. & paging speakers.
Multiple paging zones and channels.
One PD-2 for paging with talkback.
Must be powered by TD-H’s power supply
PS-12A/12C.
Use paging speakers SP-3NA (SP-5N in
USA).
Connection to background music source.
* PD-2 paging adaptor w/ talkback
Paging
speakers
Talkback speaker
_ Toan assigned No. terminal
; + oT - - | | 7 7 | - 7 - )
TD-6H/B
(w/ TDW-6/A)
To PS-12A/12C
(of TD-H phone)
PS-12A/12C
EM Call extension relay RY-AC/A
TD-6H/B
(w/ TDW-6/A)| ||,
RY-AC/A will activate when station #3 receives
a call from a handset station. It lasts as long as
that TD-H station is ringing.
Buzzer ratings:
0.3A 240V AC or
1.0A 24V DC,
mechanical type
only
MOUNTING
Xx Make sure PS-12A/12C is unplugged while making
wiring connections.
* When drawing out a TD-H station’s wires from trunk
cable, connect each junction with secured insulation.
Or use TDW-n terminal box, allowing plug-in to TD-nH
on 1.5m cord end.
Hl TD-nH wall-mounting (on gang box)
1. Loosen a front bottom screw.
2. Lift the front case off the chassis, and unplug CN1 ~
3 connectors (varies by model) to disconnect
intercom.
3. Mount the chassis to single-gang box with 2 screws
supplied.
4. Make wire termination on each screw terminal
inside the chassis.
5. Plug in CN connectors back to each socket.
6. Remount front case to chassis, fastening bottom
SCrew.
* Put together the connector leads to avoid pinching
by hook knob or front case.
H TD-nH desk or surface wall mounting
Use TDW-n box for either desk-top
or surface wall mounting.
TDW box
Cable protector
1.5m,5'
long
TDW
box
Cable protector
% Install TDW-n and cable in
non-trapping manner.
Loosen a screw
_—
3 0
— TDW-24/A
|
т
83.5mm
(3-5/16")
{OHO SH, oS, H Ik
Ол AA
|
Cable clamp
Xx Anchor TDW-n cord on the
chassis
¡see
Ty
[=
J
E
[=]
|
tul
=
|
Er
=
|
al
=
|
Er
E
SE
Y
… Fasten with
E
+)
:
ne
=
|
№ чт
sie
=
|
a
=
self supplied
Ва
in
Г
TDW-n cord
TD-24H/B Chassis
a screw 3X6,
ire-nut,etc.
TD-H trunk cable
CN connectors: CN-1 on TD-1H/B, 3H/B
CN-1, 2 on TD-6H/B, 12H/B
CN-1 - 3 on TD-24H/B
TD-24H/B ener
Single-gang box
Chassis
Screw(2)
supplied
Unplug
CN4,5
Chassis
inside
% Fasten TDW-n cord or
station cable with a clamp
(Cut off the parts from
TD-1~12H/B chassis).
Attach 1.
— 10 —
Xx The CN-1,2 and CN-4,5
connectors, becoming,
inutilized, should be folded
neatly, and not be cut off.
TDW-24/A box
TD-3~12H/B
Front case
CN2 : TD-6H/B & TD-12H/B only
OPERATIONS on TD-H
Station # button selects a TD-H intercom, a zone for page, or a door station.
TD-24H/B
NM Basic operations
* Calling other TD-H
CALL
TREMOLO
Depress to lock a station- The TD-H station rings Communicate with handset
Pick up TD-H handset. select button and press CALL tremolo tone. Pick up on both stations. After com-
button momentarily. handset to reply. munication, both stations
CALLA hang up.
* On TD-24H/B, depress CALL A
to call A1~A12 stations.
* If handset is not replaced,
that station will not ring.
se Receiving a call from TD-H When tremolo tone rings on your TD-H station, simply pick up to reply.
H To talk with a door station
Call button is depressed. Tremolo tone rings Reply to door
for approx. 2.5 Depress to lock a door- station.
seconds. assigned # button.
Ш Zone page
Pick up handset. Depress to lock a zone- Depress PAGE button inside Page while holding down Hang up handset.
assigned # button. handset. Pre-tone notifies PAGE button. Release PAGE
through zone’s speakers button to receive talkback reply.
(with PD-2 only)
E Call extension buzzer Ш Filling in directory
Using the RY-AC/A relay, a call from another TD-H or door station activates a ll:
separate buzzer (not supplied by Aiphone) while the TD-H station is ringing. Pick up ecos op, fil In and OS
(and select the door) on the TD-H station. door / page zone #'s. Push on
Ш Multiple talk paths are available for intercom and paging bottom of directory cover.
Xx If you hear someone speaking after depressing a TD-H station’s # button, the
station is busy. Hang up and call later.
— 11 -
CLEANING THE EQUIPMENT
1. Clean intercom unit surface with a soft and dry cloth.
2. When the soil is not easily cleaned, the cloth may be dampened with neutral
household cleanser. Never use an abrasive cleaner or cloth.
TECHNICAL PRECAUTIONS
Door-assigned # button x It is suggested, on TD-24H/B to assign a number button 1~12 for
door station(s) or paging zone(s), so they can be addressed by
depressing only the station # button. Do not use A1~A12.
Station select break-in call % TD-H allows any station(s) to join on the conversation by station
selection.
Paging * Do not select and page to more than one zone simultaneously.
SPECIFICATIONS
Power source DC 12V. Max. 70mA per station.
Use PS-12A or PS-12C power supply for a system.
Calling Station-select button 1 - 12 and Call button, rings with tremolo tone.
Rings while Call button is held down. (On TD-24H/B, 1 ~ 12 and Call A button
rings A1 ~ A12 stations)
Communication Multi-talk path, simultaneous intercom. When called by tremolo
from other station, pick up the handset.
Added feature counts as a station, assigning a select # button (any) on TD-H station(s).
Door station Max. 2 door stations |E/IF Series or PanTilt video, using DE-UR for each.
- Rings max. 12 TD-H stations with intermittent tremoto, 2.5 sec.-timed.
* Call tone selector A or B on DE-UR for 2 doors.
Zone page Multiple zones, using a PD-1 or PD-2 (w/talkback), amplifier and an
appropriaie number of speakers for each.
Wiring TD-1H/B | TD-3H/B | TD-6H/B | TD-12H/B TD-24H/B
4. cond. 7 cond. 10 cond. 16 cond. | 28 cond.
3 wires common + 1 for each selective calling
Wiring distance 650m with 0.6eemm diameter. 2,000” with 22AWG.
Dimensions
TD-nH/B (n=1,3,6,12) 210mm high x 100mm wide x 73mm deep. 8-1/4”H x 3-15/16”W x 2-7/8"D
TD-24H/B Same, except 83mm, 3-1/4” deep
Weight TD-1H/B ... 4109 (0.90 Ibs.) TD-3H/B … 430g (0.95 lbs.) TD-6H/B ... 440g (0.97 Ibs.)
TD-12H/B ... 460g (1.01 Ibs.) TD-24H/B ... 520g (1.14 Ibs.)
soos ole ole aja edo ojo ojo efe ajo ajo elo efe ajo ajo eje ojo ajo ajo ojo ajo fu ajo ajo ato ajo ajo ate ote ata ole oe ole ole ajo eto ato ato ato ajo ato ojo ajo ajo ajo ato ata ajo ojo ata ato eto ato ate ata ote ata efe ajo ote ово rte ate ate
WARRANTY
A:phone warrants its products to be free from defects of material and workmanship under normal use and service for a
period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it
become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself
the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the
product 1s within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in
violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This
warranty does not cover batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by
Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
FREER REFEREE ERE EES
Fb dE Ebb bbb Ebb eb
Aiphone Co., Ltd., Nagoya, Japan COMMUNICATION SYSTEMS
Aiphone Corporation, Bellevue. WA, USA |
HOME, BUSINESS, INDUSTRY.
TD-H/B-I(E) 12951 Printed in Hong Kong (E)