INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
The Vail Premium Vent-Free
Multi-Sided Fireplaces
see-through fireplace models:
vfp36sp32en-1
vfp36sp32ep-1
peninsula fireplace models:
vfp36pp32en-1
vfp36pp32ep-1
GAS-FIRED
U.L. File: MH46389
ANSI Z21.11.2 Gas Fired Decorative Type Unvented Room
Heaters.
Installer: Leave this manual with the appliance.
Consumer:Retain this manual for future reference.
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be
provided. Refer to page 8.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel or
from fuel combustion which can cause death or serious illness.
Water Vapor: A By-Product of Unvented
Room Heaters
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU's (.3KW's)
of gas input per hour. Refer to page 8.
Page 1
TABLE OF CONTENTS
SECTIONPAGE
Carton Contents.......................................................................................................................3
Hardware Package...................................................................................................................3
Important Safety Information..................................................................................................4
Safety Information for Users of LP-Gas.................................................................................5
Introduction.............................................................................................................................6
Specifications..........................................................................................................................7
Water Vapor: A By-Product of Unvented Room Heaters........................................................8
Provisions for Adequate Combustion & Ventilation Air..................................................... 8-9
Gas Supply............................................................................................................................10
Clearances....................................................................................................................... 11-12
Combustible Materials..........................................................................................................12
Planning Installation..............................................................................................................13
Fireplace Installation Instructions................................................................................... 13-15
Installing Hoods....................................................................................................................16
Gas Line Connection.............................................................................................................17
Placement of Glowing Embers and Lava Rock.....................................................................18
Operation Instructions/Flame Appearance............................................................................19
VFP36(SP,PP)32 Lighting Instructions.................................................................................20
Burner Instructions................................................................................................................21
Pilot Flame Characteristics....................................................................................................22
Wiring....................................................................................................................................23
Troubleshooting Symptoms - Possible Causes and Solutions...............................................24
Wiring Instructions for Installing a Dual Switch/Receptacle................................................25
Optional Blower Installation Instructions....................................................................... 26-28
LK2 Accent Light Accessory................................................................................................29
Maintenance..........................................................................................................................29
Parts List.......................................................................................................................... 30-31
How To Order Repair Parts...................................................................................................31
See-Through Fireplace Parts View........................................................................................32
Peninsula Fireplace Parts View.............................................................................................33
Accessories...................................................................................................................... 34-35
Service Notes.........................................................................................................................36
Reference......................................................................................................................... 37-39
Page 2
24309-1-0908
CARTON CONTENTS
Fireplace Assembly
Lava Rock Package
Soot Warning Sheet
Installation Package
Rockwool Packet
Installation Instructions
Serial Number Tag
Warranty Card
Hardware Package (See Figure Below)
Nailing Flange
#10 x 1/2" Phillips Hex Head Screw
#10 x 1/2" Phillips Truss Head Screw
Romex Connector
HARDWARE PACKAGE
#10 X ½” PHILLIPS HEX HEAD SCREW (16)
#10 X ½” PHILLIPS HEX HEAD SCREW (20)
NAILING FLANGE (8)
ROMEX CONNECTOR (2)
Note: Hardware shown to scale where possible.
Note: Two hardware packages are included in the carton contents. Hardware quantities shown above are total received.
24309-1-0908
Page 3
IMPORTANT SAFETY INFORMATION
•
•
•
•
•
•
•
•
•
•
•
An unvented room heater having an input rating of more than
6,000 Btu per hour shall not be installed in a bathroom
An unvented room heater having an input rating of more than
10,000 Btu per hour shall not be installed in a bedroom or
bathroom.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazard of high
surface temperature and should stay away to avoid burns or
clothing ignition.
Young children should be carefully supervised when they are
in the same room with the appliance.
Do not place clothing or other flammable material on or near
the appliance.
Installation and repair should be done by a qualified
service person. This appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding materials, etc. It
is imperative that control compartments, burners and
circulating air passageways of the appliance be kept clean.
Do not use this room heater if any part has been under
water. Immediately call a qualified service technician to
inspect the room heater and to replace any part of the control
system and any gas control which has been under water.
You must operate heater with fireplace screen in place.
Do not place trash, logs or other articles on the log set during
operation.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
films or bonding agents. These bonding agents are not harmful
but may produce annoying smoke and smells as they are
burned off during initial operation of the appliance. This is
a normal temporary occurrence. A window should be opened
during the initial bake out period.
•
•
•
•
•
•
•
Correct installation of the ceramic fiber logs, proper
location of the heater and annual cleaning are necessary to
avoid potential problems with sooting. Sooting, resulting
from improper installation or operation, can settle on
surfaces outside the fireplace. See instructions for proper
installation.
WARNING: Do not allow fans to blow directly into
the fireplace. Avoid any drafts that alter burner flame
patterns.
WARNING: Do not use a blower insert, heat exchanger insert
or other accessory not approved for use with this heater.
WARNING! This fireplace needs fresh air for ventilation to
run properly. This fireplace has an ODS (oxygen depletion
sensor) which will shut down the heater if adequate fresh
air is not available. See troubleshooting section in the
instructions.
WARNING: DO NOT operate this appliance unless
all components including logs, burners, and controls
are in good working condition. Never operate this
appliance if any log or twig is broken, or out of their
intended position. Refer to the Log set placement
instructions for correct log and twig positioning.
Replacement components are available through your local
dealer as indicated in the How to Order Repair Parts
section of the appliance manual.
Keep appliance area clear and free from combustible
materials, gasoline and other flammable vapors and
liquids.
WARNING: Failure to keep the primary air opening(s)
of the burner(s) clean may result in sooting and property
damage.
warning
When used without adequate combustion and ventilation air,
heater may give off CARBON MONOXIDE, an odorless, poisonous gas.
Do not install heater until all necessary provisions are
made for combustion and ventilation air. Consult the written instructions provided with the heater for information
concerning combustion and ventilation air. In the absence
of instructions, refer to the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Air for Combustion and Ventilation, or
applicable local codes.
This heater is equipped with a pilot light safety system designed to turn off the heater if not enough fresh air
is available.
Do NOT TAMPER WITH PILOT LIGHT SAFETY
SYSTEM!
If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and
control compartment clean.
Page 4
Carbon monoxide poisoning may lead to
death.
Early signs of carbon monoxide poisoning resemble the flu,
with headache, dizziness and/or nausea. If you have these signs,
heater may not be working properly. Get fresh air at once!
Have heater serviced.
Some people — pregnant women, persons with heart or lung
disease, anemia, those under the influence of alcohol , those at
high altitudes — are more affected by carbon monoxide than
others.
The pilot light safety system senses the depletion of oxygen at its
location. If this heater is installed in a structure having a high
vertical dimension, the possibility exists that the oxygen supply
at the higher levels will be less than that at the heater. In this type
of application, a fan to circulate the structure air will minimize
this effect. The use of this fan will also improve the comfort level
in the structure. When a fan is used to circulate air, it should be
located so that the air flow is not directed at the burner.
24309-1-0908
SAFETY INFORMATION FOR USERS OF LP-GAS
Propane (LP-Gas) is a flammable gas which can cause fires
and explosions. In its natural state, propane is odorless and
colorless. You may not know all the following safety precautions which can protect both you and your family from an
accident. Read them carefully now, then review them point
by point with the members of your household. Someday when
there may not be a minute to lose, everyone's safety will depend
on knowing exactly what to do. If, after reading the following
information, you feel you still need more information, please
contact your gas supplier.
LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.
That's your signal to go into immediate action!
•
Do not operate electric switches, light matches, use your
phone. Do not do anything that could ignite the gas.
• Get everyone out of the building, vehicle, trailer, or area. Do
that IMMEDIATELY.
• Close all gas tank or cylinder supply valves.
• LP-Gas is heavier than air and may settle in low areas such
as basements. When you have reason to suspect a gas leak,
keep out of basements and other low areas. Stay out until
firefighters declare them to be safe.
• Use your neighbor's phone and call a trained LP-Gas service
person and the fire department. Even though you may not
continue to smell gas, do not turn on the gas again. Do not
re-enter the building, vehicle, trailer, or area.
• Finally, let the service man and firefighters check for escaped
gas. Have them air out the area before you return. Properly
trained LP-Gas service people should repair the leak, then
check and relight the gas appliance for you.
no odor detected - odor fade
Some people cannot smell well. Some people cannot smell the
odor of the chemical put into the gas. You must find out if you
can smell the odorant in propane. Smoking can decrease your
ability to smell. Being around an odor for a time can affect your
sensitivity or ability to detect that odor. Sometimes other odors
in the area mask the gas odor. People may not smell the gas odor
or their minds are on something else. Thinking about smelling a
gas odor can make it easier to smell.
The odorant in LP-gas is colorless, and it can fade under some
circumstances. For example, if there is an underground leak, the
movement of the gas through soil can filter the odorant. Odorants
in LP-Gas also are subject to oxidation. This fading can occur if
there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls,
masonry and other materials and fabrics in a room. That will take
some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could
vary at different levels. Since it is heavier than air, there may be
more odor at lower levels. Always be sensitive to the slightest gas
odor. If you detect any odor, treat it as a serious leak. Immediately
go into action as instructed earlier.
some points to remember
•
Learn to recognize the odor of LP-gas. Your local LP-Gas
Dealer can give you a "Scratch and Sniff" pamphlet. Use it
to find out what the propane odor smells like. If you suspect
that your LP-Gas has a weak or abnormal odor, call your
LP-Gas Dealer.
•
If you are not qualified, do not light pilot lights, perform
service, or make adjustments to appliances on the LP-Gas
system. If you are qualified, consciously think about the odor
of LP-Gas prior to and while lighting pilot lights or performing service or making adjustments.
•
Sometimes a basement or a closed-up house has a musty
smell that can cover up the LP-Gas odor. Do not try to light
pilot lights, perform service, or make adjustments in an area
where the conditions are such that you may not detect the
odor if there has been a leak of LP-Gas.
•
Odor fade, due to oxidation by rust or adsorption on walls of
new cylinders and tanks, is possible. Therefore, people should
be particularly alert and careful when new tanks or cylinders
are placed in service. Odor fade can occur in new tanks, or
reinstalled old tanks, if they are filled and allowed to set too
24309-1-0908
long before refilling. Cylinders and tanks which have been
out of service for a time may develop internal rust which will
cause odor fade. If such conditions are suspected to exist, a
periodic sniff test of the gas is advisable. If you have any
question about the gas odor, call your lp-gas dealer. A
periodic sniff test of the lp-gas is a good safety measure
under any condition.
•
If, at any time, you do not smell the LP-Gas odorant and you
think you should, assume you have a leak. Then take the same
immediate action recommended above for the occasion when
you do detect the odorized LP-Gas.
•
If you experience a complete "gas out," (the container is under no vapor pressure), turn the tank valve off immediately.
If the container valve is left on, the container may draw in
some air through openings such as pilot light orifices. If this
occurs, some new internal rusting could occur. If the valve is
left open, then treat the container as a new tank. Always be
sure your container is under vapor pressure by turning it off
at the container before it goes completely empty or having it
refilled before it is completely empty.
Page 5
INTRODUCTION
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with unvented room heater.
3. Installer should show owner how to start and operate unvented
room heater.
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
an unvented room heater.
This appliance may be installed in an aftermarket* manufactured
(mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
Warning: Any change to this HEATER or its
controls can be dangerous.
Improper installation or use of the heater can cause serious
injury or death from fire, burns, explosion or carbon
monoxide poisoning.
This series is design certified in accordance with American National
Standard Z21.11.2 by the Underweriters Laboratories, Inc. as an
Unvented Room Heater and should be installed according to these
instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown on
the rating plate is the responsibility of the person and company
making the change.
750 Millivolt System
When you ignite the pilot, the thermocouple produces millivolts
(electrical current) which energizes the magnet in the gas valve.
After 30 seconds to 1 minute time period you can release the gas
control knob and the pilot will stay ON. Allow your pilot flame to
operate an additional one (1) to two (2) minutes before you turn the
gas control knob from the PILOT position to the ON position. This
time period allows the millivolts (electrical energy) to build-up to
a sufficient level allowing the gas control to operate properly.
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Attention: During initial use of ceramic log you will detect an
odor as the ceramic log is cured. Also, during the curing process
the ceramic log will burn with a yellow flame.
Notice: During initial firing of this unit, its paint will bake out, and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
Page 6
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Solid-fuels shall not be burned in a masonry or UL 127 factorybuilt fireplace in which an unvented room heater is installed.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation or company which either in
person or through a representative is engaged in and is responsible
for (a) the installation or replacement of gas piping or (b) the
connection, installation, repair or servicing of equipment, who is
experienced in such work, familiar with all precautions required
and has complied with all the requirements of the authority having
jurisdiction.
State of Massachusetts: The installation must be made by
a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the Sate of Massachusetts, unvented propane and natural
gas-fired space heaters shall be prohibited in bedrooms and
bathrooms.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, International Fuel
Gas Code, ANSI Z223.1.*
*Available from the American National Standards Institute, Inc. 1430 Broadway,
New York, N.Y. 10018.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level. Contact the manufacturer or your gas company before
changing spud/orifice size.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the
Btu output of the unit. Contact the gas company for the heating
value. Contact the manufacturer or your gas company before
changing spud/orifice size.
WARNING: This appliance is equipped for (natural gas or
propane) gas. Field conversion is not permitted.
24309-1-0908
SPECIFICATIONS
Model
Input Maximum
Minimum
Overall Dimensions
Height without standoff
Width
Depth
Gas Inlet
VFP36(SP,PP)32EN (NAT)
38,000
25,000
VFP36(SP,PP)32EP (LP)
38,000
30,000
37 3/4"
39"
24"
3/8"
37 3/4"
39"
24"
3/8"
Log Sets (Ordered Separately)
LSU24RR-2
Rock Creek Logs
Accessories
EK-1
EK2
PE-20
FBB4
FRBC
FRBTC
FRBTP
FREC
FWS
TMV
TRW
LK2
Embers Kit
Embers Kit
Platinum Embers
Variable Speed Automatic Blower
Battery Operated Remote Control
Battery Operated Remote Control with Thermostat
Remote-Battery Operated with Programmable Thermostat
Electric Remote Control
Wall Switch
Wall Thermostat, Millivolt - Reed Switch
Remote Wall Thermostat
Accent Light Kit
24309-1-0908
Page 7
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An unvented room
heater produces approximately one (1) ounce (30ml) of water for
every 1,000 BTU's (.3KW's) of gas input per hour.
Unvented room heaters are recommended as supplemental heat (a
room) rather than a primary heat source (an entire house). In most
supplemental heat applications, the water vapor does not create a
problem. In most applications, the water vapor enhances the low
humidity atmosphere experienced during cold weather.
The following steps will help insure that water vapor does not
become a problem.
1. Be sure the heater is sized properly for the application, including
ample combustion air and circulation air.
2. If high humidity is experienced, a dehumidifier may be used to
help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat
source.
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
This heater shall not be installed in a confined space or unusually
tight construction unless provisions are provided for adequate
combustion and ventilation air.
The National Fuel Gas Code, ANSI Z223.1 defines a confined space
as a space whose volume is less than 50 cubic feet per 1,000 Btu per
hour (4.8m3 per kw) of the aggregate input rating of all appliances
installed in that space and an unconfined space as a space whose
volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3
per kw) of the aggregate input rating of all appliances installed in
that space. Rooms communicating directly with the space in which
the appliances are installed, through openings not furnished with
doors, are considered a part of the unconfined space.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh
air.
Unusually tight construction is defined as construction
where:
a. Walls and ceilings exposed to the outside atmosphere have
a continuous water vapor retarder with a rating of one perm
or less with openings gasketed or sealed, and
b. Weather-stripping has been added on openable windows and
doors, and
c. Caulking or sealants are applied to areas such as joints
around window and door frames, between sole plates and
floors, between wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical, and gas lines, and at
other openings.
If your home meets all of the three criteria above, you must provide
additional fresh air. See “Ventilation Air From Outdoors,”
page 9.
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined
space.
Space: Includes the room in which you will install heater plus any
adjoining rooms with doorless passageways or ventilation grills
between the rooms.
Page 8
1. Determine the volume of the space (length x width x height).
Length x Width x Height =
cu. ft. (volume of
space)
Example: Space size 16 ft. (length) x 10 ft. (width) x 8 ft. (ceiling
height) = 1,280 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills
or openings, add the volume of these rooms to the total volume
of the space.
2. Divide the space volume by 50 cubic feet to determine the
maximum BTU/Hr the space can support.
(volume of space) ÷ 50 cu. ft. = (maximum
BTU/Hr the space can support)
Example: 1,280 cu. ft. (volume of space) ÷ 50 cu. ft. = 25.6 or
25,600 (maximum BTU/Hr the space can support)
3. Add the BTU/Hr of all fuel burning appliances in the space.
Vent-free heater BTU/Hr
Gas water heater
BTU/Hr
Gas furnace
BTU/Hr
Vented gas heater
BTU/Hr
Gas fireplace logs
BTU/Hr
Other gas appliances* + BTU/Hr
Total
=
BTU/Hr
Example: Vented gas heater
20,000
BTU/Hr
Vent-free heater
+ 18,000
BTU/Hr
Total
=
38,000
BTU/Hr
*Do not include direct-vent gas appliances. Direct vent draws
combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum BTU/Hr the space can support with the
actual amount of BTU/Hr used.
BTU/Hr (maximum the space can support)
BTU/Hr (actual amount of BTU/Hr used)
Example:
25,600
BTU/Hr (maximum the space can support)
38,000
BTU/Hr (actual amount of BTU/Hr used)
Warning: If the area in which the heater may be operated is smaller
than that defined as an unconfined space or if the building is of
unusually tight construction, provide adequate combustion and
ventilation air by one of the methods described in the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and
Ventilation, or applicable local codes.
24309-1-0908
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR (continued)
The space in the above example is a confined space because the
actual BTU/Hr used is more than the maximum BTU/HR the space
can support. You must provide additional fresh air. Your options
are as follows:
A. Rework worksheet, adding the space of an adjoining room. If
the extra space provides an unconfined space, remove door to
adjoining room or add ventilation grills between rooms. See
Ventilation Air From Inside Building.
B. Vent room directly to the outdoors. See Ventilation Air From
Outdoors.
C. Install a lower BTU/Hr heater, if lower BTU/Hr size makes
room unconfined.
If the actual BTU/Hr used is less than the maximum BTU/Hr the
space can support, the space is an unconfined space. You will need
no additional fresh air ventilation.
Warning: You must provide additional ventilation air
in a confined space.
Ventilation Air From Outdoors (Figure 2)
Provide extra fresh air by using ventilation grills or ducts. You must
provide two permanent openings: one within 12" of the ceiling
and one with 12" of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These spaces include
attics and crawl spaces. In most cases for direct communication
with the outdoors or direct communication through a vertical duct
a free area opening of one square inch per 4,000 BTU/Hr of heater
input rating for each grill. If a horizontal duct is used, a grill free
area or duct opening shall have a free area opening of one square
inch per 2,000 BTU/Hr for each grill. Follow the National Fuel
Code ANSI Z223.1/NFPA54, Air for Combustion and Ventilation
for required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet air into
attic if attic has a thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Ventilation Air
Ventilation Air From Inside Building (Figure 1)
This fresh air would come from an adjoining unconfined space.
When ventilating to an adjoining unconfined space, you must
provide two permanent openings: one within 12" of the ceiling
and one within 12" of the floor on the wall connecting the two
spaces (see options 1 and 2, Figure 1). You can also remove door
into adjoining room (see option 3, Figure 1). Each ventilation grill
or opening shall have a minimum free area of one square inch per
1,000 BTUH of the total input rating of the gas equipment in the
confined space.
Figure 2
Figure 1
Warning: Rework worksheet, adding the space of the
adjoining unconfined space. The combined spaces must have
enough fresh air to supply all appliances in both spaces.
24309-1-0908
Page 9
GAS SUPPLY
Check all local codes for requirements, especially for the size and
type of gas supply line required.
Recommended Gas Pipe Diameter
Pipe Length Schedule 40 Pipe
Tubing, Type L
Inside Diameter
Outside Diameter
Nat.
L.P.
Nat.
L.P.
0-10 feet
1/2”
3/8”
1/2”
3/8”
0-3 meters 12.7mm 9.5mm 12.7mm 9.5mm
10-40 feet
1/2”
1/2”
5/8”
1/2”
4-12 meters 12.7mm 12.7mm 15.9mm 12.7mm
40-100 feet
1/2”
1/2”
3/4”
1/2”
13-30 meters 12.7mm 12.7mm 19mm 12.7mm
100-150 feet
3/4”
1/2”
7/8”
3/4”
31-46 meters 19mm 12.7mm 22.2mm 19mm
Note: Never use plastic pipe. Check to confirm whether your local
codes allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is
always best to consult your local authority and installation code.
Installing a New Main Gas Cock
Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of
the unit. Where none exists, or where its size or location is not
adequate, contact your local authorized installer for installation
or relocation.
Compounds used on threaded joints of gas piping shall be resistant
to the action of liquefied petroleum gases. The gas lines must be
checked for leaks by the installer. This should be done with a soap
solution watching for bubbles on all exposed connections, and if
unexposed, a pressure test should be made.
Never use an exposed flame to check for leaks. Appliance must
be disconnected from piping at inlet of control valve and pipe
capped or plugged for pressure test. Never pressure test with
appliance connected; control valve will sustain damage!
A gas valve and ground joint union should be installed in the gas
line upstream of the gas control to aid in servicing. It is required
by the National Fuel Gas Code that a drip line be installed near
the gas inlet. This should consist of a vertical length of pipe tee
connected into the gas line that is capped on the bottom in which
condensation and foreign particles may collect.
Figure 3
Checking Manifold Pressure
VFP36(SP,PP)32EN (Natural gas) will have a manifold pressure
of approximately 3.5" w.c. (.871kPa) for maximum input or
1.7" w.c. (.423kPa) for minimum input at the pressure regulator outlet
with the inlet pressure to the pressure regulator from a minimum
of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a
maximum of 10.5" w.c. (2.614kPa).
VFP36(SP,PP)32EP (Propane gas) will have a manifold pressure
approximately 10.0"w.c. (2.49kPa) at the pressure regulator outlet
with the inlet pressure to the pressure regulator from a minimum
of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a
maximum of 13.0"w.c. (3.237kPa).
A test gage connection is located downstream of the gas appliance
pressure regulator for measuring gas pressure. The connection is a
1/8 inch (3mm) N.P.T. plugged tapping.
VFP36(SP,PP)32 Millivolt Control
The valve regulator controls the burner pressure which should be
checked at the pressure test point. Turn captured screw counter
clockwise 2 or 3 turns and then place tubing to pressure gauge over
test point (Use test point “A” closest to control knob). After taking
pressure reading, be sure and turn captured screw clockwise firmly
to re-seal. Do not over torque. Check for gas leaks.
The use of the following gas connectors is recommended:
— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings
— ANS Z21.45 Assembled Flexible Appliance Connectors of
Other Than All-Metal Construction
The above connectors may be used if acceptable by the authority
having jurisdiction The state of Massachusetts requires that a flexible
appliance connector cannot exceed three feet in length.
Page 10
24309-1-0908
CLEARANCES
Sidewall Clearances: The clearance from the inside of the fireplace
to perpendicular combustible side wall should not be less than
1 3/4". See Figures 4a and 4b.
Combustible material clearance from front of firebox: 36"
minimum
Fireplace Side and Back Clearances: The fireplace outer casing
side(s) require a minimum 1/2" clearance to combustibles.
Top Framing and Finishing: Combustible framing may rest on
top of standoffs. Combustible finishing materials may extend to
the top standoff screws on the front edge of the top outer wrap.
See Figure 5.
1 3/4” MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
42”
MIN.
(CEILING TO
TOP OF HOOD)
COMBUSTIBLE
FINISHED WALL
OR MANTEL
2X4
HEADER
TOP OUTER
WRAP
STAND OFF
FINISH WITH TRIM KIT
OR NON-COMBUSTIBLE
MATERIAL AS DESIRED.
FIREBOX
36”
MIN.
Figure 4a - See Through Fireplace Clearances
1 3/4” MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
Figure 5
42”
MIN.
(CEILING TO
TOP OF HOOD)
36”
MIN.
Figure 4b - Peninsula Fireplace Clearances
24309-1-0908
Page 11
CLEARANCES (cont.)
Ceiling Clearances: The ceiling height should not be less than 42"
from the top of the hood. See Figures 6a and 6b.
able for each model. If a combustible mantel is installed, it must
meet the clearance requirements detailed below.
Mantel Clearances: Vent free fireplace models must use the hood
supplied with the fireplace, or one of the optional hood kits avail-
Leave furniture and other combustible items at least 36" away from
the front openings of the fireplace.
CEILING
CEILING
12”
MAX
10”
12”
MAX
10”
MANTEL
42”
MIN.
(CEILING TO
TOP OF HOOD)
MANTEL
COMBUSTIBLES
ALLOWED
8”
15”
6 ½”
24 ½”
42”
MIN.
(CEILING TO
TOP OF HOOD)
22”
20”
13”
5”
84”
MIN.
(CEILING TO FLOOR)
17 ½”
8” COMBUSTIBLES
ALLOWED
6 ½”
5”
18”
11”
3 ½”
13”
3 ½”
9”
1 ½”
16”
84”
MIN.
(CEILING TO FLOOR)
2 ½”
14 ½”
6 ½”
0”
4 ½”
MIN.
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
STANDARD
OF FIREPLACE
HOOD
FIREBOX
FACE
8”
MIN.
0”
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREPLACE
EXTENDED HOOD
(VB4H SERIES)
(NOT AVAILABLE ON
PENINSULA OPEN END)
FIREBOX
FACE
Figure 6a - Mantel Clearances with Standard Hood
Figure 6b - Mantel Clearances with Optional Extended Hood
COMBUSTIBLE MATERIALS
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
Figure 7
Figure 8
Page 12
24309-1-0908
PLANNING INSTALLATION
In planning the installation for the fireplace, it is necessary to
determine where the unit is to be installed and whether optional
accessories are desired. Gas supply piping should also be planned
at this time. A gas shutoff must be installed in this line.
If the fireplace is installed directly on carpeting, tile or other
combustible material other than wood flooring, it should be installed
on a metal or wood panel extending the full width and depth of
the unit.
The fireplace can be mounted on any of these surfaces:
1. A flat hard combustible or non-combustible surface.
2. A raised platform of combustible or non-combustible
material.
3. Four (4) corners of the fireplace so contact is made on all four
perimeter edges on the bottom of the unit.
(Example: Four (4) concrete masonry blocks.)
At this point, you should have decided what components to include
in your installation, and where the fireplace is to be located. If this
has not been done, stop and consult your dealer for assistance with
this planning.
Accessory kits such as the FBB5 Blower kit, Trim kits, Mantles,
plus other Decorative Frame, Hood, and Door accessory kits may
be installed after the fireplace is secured to the framing.
Refer to the instructions provided with each of the optional
accessory kits for proper installation and operation.
FIREPLACE INSTALLATION INSTRUCTIONS
Fireplace Framing
Framing can be built before or after the fireplace is set in place.
Framing should be constructed to accommodate wall covering
and fireplace facing material. The fireplace framing should be
constructed of 2 x 4 lumber or heavier. The framing headers may
rest on the top of the fireplace standoffs. Refer to Figures 5 and 9
for framing dimensions.
Note: On Peninsula models, a maximum weight of 250 lbs. is
recommended when construction materials are supported by the
top standoff spacers.
A
C
B
Framing - Peninsula
Premium Vent-Free Fireplace Framing Dimensions (in
inches)
"A"
"B"
"C"*
Model
Framing
Framing
Framing
Height
Width
Depth
VFP36SP
38"
40"
23"*
VFP36PP
38"
39"**
23"*
Attention: Add height of base to "A" Dimension when elevating fireplace if installing on an elevated base.
Framing dimension A incudes a three inch clearance for
standoffs on top of fireplace.
*Dimension "C" assumes use of 1/2" wall board flush to both
front faces.
** Peninsula model framing width assumes use of 1/2" wall
board flush to the end face.
Figure 9
24309-1-0908
A
C
B
Framing - See-Through
Page 13
FIREPLACE INSTALLATION INSTRUCTIONS (continued)
2 9/16”
2 9/16”
2 9/16”
G
C
SEE THRU
LOUVERED
PENINSULA
LOUVERED
DMN AH
F
F
K
DMN AH
K
J
J
L
E
B
L
I
E
B
A
VFP36SP
34 3/4"
VFP36PP
34 3/4"
B
C
D
E
F
G
39"
24"
22"
36"
34 1/4"
29 1/8"
39"
24"
22"
36"
35 1/4"
29 1/8"
H
I
J
K
L
M
N
37 3/4"
1 1/4"
6 1/8"
2 1/2"
5"
24 1/8"
33 1/2"
37 3/4"
1 1/4"
6 1/8"
2 1/2"
5"
24 1/8"
33 1/2"
I
Figure 10
Fireplace Dimensions
Page 14
24309-1-0908
FIREPLACE INSTALLATION INSTRUCTIONS (continued)
Locating Fireplace
Place fireplace in framed opening. Attach the framing brackets to
the fireplace and secure to framing. Different hole locations can
be used for finishing materials with thicknesses of 3/8", 1/2" and
3/4". Secure the brackets with screws provided using two (2) per
framing bracket. See Figure 11.
Framing brackets should fit directly against framing material. Use
at least one (1) nail or screw per bracket to secure in place.
IMPORTANT! Check squareness of the fireplace prior to securing
to framed opening. See Figure 12.
NOTE: On See-Through models, framing brackets may be placed
on one side of the facing openings. This allows the fireplace to be
inserted into the pre-framed opening.
ATTACH (4)
FRAMING BRACKETS
TO SIDE(S) OF FIREPLACE
PRIOR TO INSTALLING
UNIT TO FRAMED OPENING
FIREPLACE OPENING
CHECK TO SEE
THAT BOX IS SQUARE
PRIOR TO ATTACHING TO
FRAMING
Figure 12
Figure 11
24309-1-0908
Page 15
INSTALLING HOODS
Black hoods are furnished with each fireplace (or the optional
hood(s)) and MUST be installed before the fireplace is used. Failure
to do so may create a possible fire hazard. For shipping purposes,
the hoods are located behind the upper or lower louvers. If brass,
stainless steel, or hammered pewter hoods are desired, they can
be purchased as an option. Attachment is the same as the standard
black hood.
Hood Installation
1. Remove upper louver.
2. Place the top hood flange on top of the inner firebox top, then
install three screws through the firebox top from below and
screw into the pilot holes in the hood flange (B).
3. Install one (1) screw at each end of the hood as shown (C).
4. Re-install louver(s).
Caution: All hoods must be installed prior to operation of
appliance. See Figure 13.
INNER FIREBOX TOP
Extended Hoods
If your non-combustible facing material is over 1" in thickness and
will be used to finish this fireplace, extended hoods are available
that will extend out 2" farther into the room. Extended hoods are
not available for the peninsula open ends. Contact your local dealer
for details.
VB4H36BL
VB4H36BR
VB4H36SS
VB4H36HP
Extended Hoods
Standard Black (1 each)
Polished Brass (1 each)
Stainless Steel (1 each)
Hammered Pewter (1 each)
Finishing
All joints (top, bottom and sides), where the wall or decorative
facing material meets the fireplace surround should be sealed with
a non-combustible material.
Hearth extensions are not required for these fireplaces.
Louvers and decorative louver panels are interchangeable, and may
be mixed and matched as desired.
Attention: Flush panels may not be used on these models.
B
C
Figure 13
Page 16
24309-1-0908
GAS LINE CONNECTION
The fireplace is designed to accept a gas line for connection to the
gas valve. Have the line installed by a qualified service person in
accordance with all building codes. Consult local building codes
to properly size the gas supply line leading to the connection of the
valve. The state of Massachusetts requires that a flexible appliance
connector cannot exceed three feet in length.
Gas access holes are provided through the side panel(s) of the
fireplace. See Figure 14.
Check gas type. Use only the gas type indicated on the rating plate.
If the gas listed on the plate is not your type of gas supply, DO NOT
INSTALL. Contact your dealer for proper model.
GAS LINE
ACCESS
HOLES
Always use an external regulator to reduce the supply tank pressure
to a maximum of 10.5" w.c. (NAT), or 13" w.c. (LP) See page
10.
WA R N I N G : C O N N E C T I O N D I R E C T LY TO A N
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.
24309-1-0908
Figure 14
Page 17
PLACEMENT OF GLOWING EMBERS AND LAVA ROCK
Placement of the glowing embers (rockwool) is very individual and
light coverage of the areas indicated will provide your best effects.
We recommend separation of the rockwool by hand and to make
your coverage as light and fluffy as possible.
Place just enough embers on the burner to obtain the glow and a
gold yellow flame.
Do not place rockwool over large port areas.
Placing Lava Rock in Front of Burner on Fireplace Floor
Spread lava rocks on fireplace floor in front of the burner pan.
The lava rocks are for decorative effect and are not required for
fireplace operation.
Attention: Do not place lava rocks on burner,
logs or rockwool. The lava rocks should
only be placed on the fireplace floor.
Rockwool should not be placed in the area of the pilot assembly.
Over time, the rockwool will break down and new rockwool will
need to be placed to recreate the original glowing embers effect.
Remove all old rockwool from the appliance and apply new
rockwool as shown in Figure 15.
Note: Only the rockwool supplied with this unit or ordered in
accordance with the Parts List on pages 30 and 31 should be used
on this burner. See the Parts List on pages 30 and 31 to order
replacement rockwool.
Do not cover any large ports with
ember material (glowing embers)
Do not cover any large ports with
ember material (glowing embers)
Place ember material only
over port areas as shown
Place ember material only
over port areas as shown
NAT BURNER - TOP VIEW
LP BURNER - TOP VIEW
Figure 15
Page 18
24309-1-0908
OPERATION INSTRUCTIONS/FLAME APPEARANCE
Before you begin: Do not handle the logs with your bare hands!
Always wear gloves to prevent skin irritation. After handling logs,
wash your hands gently with soap and water.
All Logs
The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the
logs are not properly and firmly positioned in the appliance.
Instructions for placement of the logs in the fireplace are included
with the logset. The logset approved for use in the VFP36(S,P)P
fireplaces is LSU24RR-2, and must be ordered separately.
Flames from the pilot (rear right back side of the pan burner) as
well as the main flame should be visually checked as the log set
is installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames. Natural gas burners
will tend to have blue flames with yellow flame tips.
NOTE: All flames will be random by design, flame height will
go up and down.
Glowing embers (rockwool) can cover the pan burner in between
the front and middle logs, but very little is necessary to cover this
area. Excess ember material causes the yellow flame to become
orange and stringy. Apply just enough to obtain slow glow and a
gold yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow fans
to blow directly into fireplace. Do not place a blower inside the
burner area of the fireplace. Ceiling fans may create drafts that alter
flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various
24309-1-0908
components of this appliance are treated with certain oils, films or
bonding agents. These chemicals are not harmful, but may produce
annoying smoke and smells as they are burned off during the initial
operation of the appliance, possibly causing headaches or eye or
lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
PERIODIC CLEANING – Refer to parts diagram for location
of items discussed below.
• Do not use cleaning fluid to clean logs or any part of heater.
• Logs - brush with soft bristle brush or vacuum with brush
attachment.
• Remove loose particles and dust from the burner areas,
controls, piezo covers and grate. Don’t remove ceramic media
from inside burner box.
• Inspect and clean burner air intake hole. Remove lint or
particles with brush. Failure to keep air intake hole clean will
result in sooting and poor combustion.
ANNUAL CLEANING/INSPECTION – Refer to parts diagram
for location of items discussed below.
• Inspect and clean burner air intake hole. Remove lint or
particles with vacuum or brush. Failure to keep air intake hole
clean will result in sooting and poor combustion.
• Inspect and clean all burner ports.
• Inspect ODS pilot for operation and accumulation of lint at air
intake holes.
• Verify flame pattern and log placement for proper operation.
• Verify smooth and responsive ignition of main burner.
• Check level of ceramic media in burner. Burner should be full,
up to the level of openings in burner top.
Page 19
vfp36(sp,pp)32 lighting instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. Before lighting smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch;
Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
•
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, don't try to repair it; call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Open bottom louver assembly.
3. Set REMOTE/OFF/ON switch to
"OFF."
4. Turn off all electric power to the
appliance (if applicable).
GAS
5. Push in gas control knob slightly
GAS CONTROL
CONTROL KNOB
KNOB
GAS
CONTROL
KNOB
SHOWN
SHOWN IN
IN "OFF"
"OFF" POSITION.
POSITION.
SHOWN
IN
"OFF"
POSITION.
and turn clockwise
to
"OFF." NOTE: Knob cannot be
REMOTE
REMOTE
REMOTE
turned from "PILOT" to "OFF" unless knob
OFF
OFF
OFF
ON
ON
is pushed in slightly. Do not force.
ON
6. Wait ten (10) minutes to clear out any gas.
PILOT
PILOT
Then smell for gas, including
PILOT
THERMOPILE
THERMOPILE
THERMOPILE
ELECTRODE
near the floor. If you smell gas,
ELECTRODE
ELECTRODE
STOP! Follow "B" in the safety
information above. If you do not
smell gas, go to the next step.
THERMOCOUPLE
7. Find pilot - Follow metal tube THERMOCOUPLE
THERMOCOUPLE
(LPG)
(LPG)
THERMOCOUPLE
from gas control. The pilot is (LPG)
THERMOCOUPLE
THERMOCOUPLE
(NATURAL)
(NATURAL)
(NATURAL)
behind the burner on the right
side.
to
8. Turn gas control knob counterclockwise
"PILOT."
9. Push in control knob all the way and hold in. Repeatedly push
the Piezo Ignitor Button until the pilot is lit. Continue to hold
the control knob in for about one (1) minute after the pilot is
lit. Release knob, and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5 through 9.
• If knob does not pop up when released, STOP and IMMEDIATELY call a qualified service technician or gas
supplier.
• If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician
or gas supplier.
10. Turn gas control knob counterclockwise
to "ON."
11. Set REMOTE/OFF/ON switch to desired setting.
12. Turn on all electric power to the appliance (if applicable).
13. Close bottom louver assembly.
TO TURN OFF GAS TO APPLIANCE
1. Open bottom louver assembly.
2. Set REMOTE/OFF/ON switch to "OFF."
3. Turn off all electric power to the appliance if service is to be
performed (if applicable).
Page 20
4. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
5. Close bottom louver assembly.
24309-1-0908
BURNER INSTRUCTIONS
Check the following items during installation prior to
lighting the multisided burner:
•
•
•
For best results when lighting the burner, have your
adjustable flame knob to the HI position, then adjust to
a lower setting after the burner has ignited.
•
When first lighting the pilot on the burner, it takes
approximately 60 to 75 seconds to fully heat and energize
the thermopile. Once the thermopile is energized, turn
on the gas valve and light the burner.
Check all carryover ports for blockage from the ceramic
media
o If there is blockage, use a small pointed tool to
move the ceramic media away from the carryover port.
Check air shutter for correct setting.
o NAT gas – Air shutter 1/8" (3.2 mm) minimum
open
AIR SHUTTER
1/8” (3.2mm) OPEN
o LP gas – Air shutter full open
AIR SHUTTER
FULL OPEN
24309-1-0908
Page 21
PILOT FLAME CHARACTERISTICS
Figure 16 show a correct pilot flame pattern. The correct flame
will be blue and will extend beyond the thermocouple. The flame
will surround the thermocouple just below the tip. A slight yellow
flame may occur where the pilot flame and main burner flame
meet. Figure 17 show an incorrect pilot flame pattern. The incorrect
pilot flame is not touching the thermocouple. This will cause the
thermocouple to cool. When the thermocouple cools, the heater
will shut down.
VFP36(SP,PP)32 PILOT
Cleaning and Pilot Maintenance
Oxygen Depletion Sensor Pilot (Figure 18)
When the pilot has a large yellow tip flame, clean the Oxygen
Depletion Sensor as follows:
1. Clean the ODS pilot by loosening nut B from the pilot tubing.
When this procedure is required, grasp nut A with an open end
wrench.
2. Blow air pressure through the holes indicated by the arrows.
This will blow out foreign materials such as dust, lint and
spider webs. Tighten nut B also by grasping nut A.
PILOT
THERMOPILE
B
A
Figure 18
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Correct Pilot Flame Pattern
Figure 16
THERMOPILE
THERMOCOUPLE
(LPG)
Warning:
Never use needles, wires, or similar cylindrical objects to
clean the pilot to avoid damaging the calibrated ruby that
controls the gas flow.
PILOT
THERMOCOUPLE
(NATURAL)
Incorrect Pilot Flame Pattern
Figure 17
If pilot flame pattern is incorrect, as shown in Figure 17
• See Troubleshooting, page 24.
Page 22
24309-1-0908
WIRING
Remote Receiver
Use the following steps to place the remote receiver adjacent to
the gas valve.
Attention: The remote receiver bracket is not used in this
installation.
1. The remote receiver can not be placed behind the gas valve and
burner assembly.
2. When facing the appliance, place the remote receiver next to
the gas valve.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110
volts. Maximum length of 20 feet of 16 AWG two (2) conductor
wires should be used with all optional switches.
Use the two leads (Red and Green) to attach optional
components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked
with a millivolt meter 0-1000 MV range.
Install remote control receiver behind bottom louver.
Refer to remote control installation and operating instructions for
more details on remote control.
WIRING DIAGRAM
H
REMOTE CONTROL RECEIVER/
THERMOSTAT/ CONTROLE E
DISTANCE DU RECEPTEUR
N
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR
GAS VALVE
VALVE DE GAZ
(OPTIONAL) REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLE E DISTANCE
DU RECEPTEUR
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
REMOTE
OFF
ON
THERMOPILE
PILOT
VEILLEUSE
THERMOCOUPLE
(LPG)
GAS VALVE
THERMOCOUPLE
(NATURAL)
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150°C
WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
150 ° C DU L'EQUIVALENT.
Figure 19
24309-1-0908
Page 23
TROUBLESHOOTING
SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS
Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.
1. When ignitor button is pressed, there is no spark at ODS/
pilot.
a. Ignitor electrode positioned wrong - Replace pilot.
b. Ignitor electrode is broken - Replace pilot.
c. Ignitor electrode not connected to ignitor cable - Reconnect
ignitor cable.
d. Ignitor cable pinched or wet. Keep ignitor cable dry - Free
ignitor cable if pinched by any metal or tubing.
e. Broken ignitor cable - Replace ignitor cable.
f. Bad piezo ignitor - Replace piezo ignitor.
2. Appliance produces unwanted odors.
a. Appliance burning vapors from paint, hair spray, glues, etc.
- Ventilate room. Stop using odor causing products while
heater is running.
b. Gas leak - Locate and correct all leaks.
3. Appliance shuts off during use. (Pilot and main burner are
off.)
a. Not enough fresh air is available for ODS/pilot to operate
- Open window and/or door for ventilation.
b. Low line pressure - Contact local gas company.
c. ODS/pilot is partially clogged - Clean ODS/pilot.
d. Defective thermocouple - Replace pilot.
4. Appliance shuts off during use. (Pilot stays on.)
a. Low line pressure - Check line pressure to the valve.
b. Defective thermopile - Check pilot flame, check wire
connections, output should be a minimum of 325 millivolts
across TH/TP and TP terminals with ON/OFF switch off.
5.Gas odor even when control knob is in OFF position.
a. Gas leak - Locate and correct all leaks.
b. Control valve defective - Replace control valve.
6. When ignitor button is pressed, there is spark at ODS/pilot,
but no ignition.
a. Gas supply turned off or manual shutoff valve closed - Turn
on gas supply or open manual shutoff valve.
b. Control knob not in PILOT position - Turn control knob
to Pilot position.
c. Control knob not pressed in while in PILOT position - Press
in control knob while in PILOT position.
d. Air in gas lines when installed - Continue holding down
control knob. Repeat igniting operation until air is
removed.
e. ODS/pilot is clogged - Replace ODS/pilot assembly or get
it serviced.
f. Gas regulator setting is not correct - Replace gas
regulator.
7.ODS/pilot lights but flame goes out when control knob is
released.
a. Control knob not fully pressed in - Press in control knob
fully.
b. Control knob not pressed in long enough - After ODS/pilot
lights, keep control knob pressed in 30 seconds.
c. Manual Shutoff valve not fully open - Fully open manual
shutoff valve.
d. Thermocouple connection loose at control valve - Hand
tighten until snug, then tighten 1/4 turn more.
e. Pilot flame not touching thermocouple, which allows
thermocouple to cool, causing pilot flame to go out. This
problem could be caused by either low gas pressure or
dirty or partially clogged ODS/pilot - Contact local gas
company.
f. Thermocouple damaged - Replace thermocouple.
g. Control valve damaged - Replace control valve.
8. Burner does not light after ODS/pilot is lit.
a. Burner orifice clogged - Clean burner or replace main burner
orifice.
b. Burner orifice diameter is too small - Replace burner
orifice.
c. Inlet gas pressure is too low - Contact qualified service
person.
9. If burning at main burner orifice occurs (a loud, roaring
blow torch noise).
a. You must turn off burner assembly and contact a qualified
service person.
b. Manifold pressure is too low - Contact local gas
company.
c. Burner orifice clogged - Clean burner or replace burner
orifice.
10. Logs appear to smoke after initial operation.
a. Vapors from paint or curing process of logs - Problem will
stop after a few hours of operation. Run the heater with the
damper open if you have one, or open a window for the
first few hours.
Log heater is intended to be smokeless. Turn OFF heater
and call qualified service person.
11.Heater produces a whistling noise when main burner is
lit.
a. Turning control knob to HIGH position when main burner
is cold - Turn control knob to LOW position and let warm
up for a minute.
b. Air in gas line - Operate burner until air is removed from
line. Have gas line checked by local gas company.
c. Dirty or partially clogged burner orifice - Clean burner or
replace burner orifice.
12. No gas to pilot.
a. LP-regulator shut down due to inlet pressure too high Verify LP tank regulator is installed and set at 11" to 13"
w.c. Replace regulator on heater.
If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the
gas quality or pressure is low, contact your local gas supplier immediately.
Page 24
24309-1-0908
WIRING INSTRUCTIONS FOR INSTALLING A DUAL SWITCH / RECEPTACLE
In order to install both the optional Blower and Accent Light accessories, it will be necessary to install the junction box so that
the Duplex Receptacle wiring is split. This will allow each side of
the receptacle to operate independently off separate wall switches.
See diagram below.
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH ALL LOCAL, CITY AND STATE BUILDING CODES.
BEFORE MAKING THE ELECTRICAL CONNECTION,
MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST
BE ELECTRICALLY GROUNDED IN ACCORDANCE
WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL
CODES, WITH THE NATIONAL ELECTRICAL CODE
ANSI/NFPA 70 (LATEST EDITION).
#1
ACCENT LIGHT
WALL SWITCH
#2
BLOWER
WALL
SWITCH
BLACK
TO 120V
CIRCUIT
BREAKER
REMOVE TAB ON HOT SIDE
OF DUPLEX RECEPTACLE
TO SPLIT LUGS
RED
PLUG
FOR
CONTROLS
BLACK
WHITE
PLUG
FOR
BLOWER
WHITE
GROUND
DOUBLE SWITCH BOX
(INSTALLER PROVIDED)
3-WIRE, GROUNDED
CONDUCTOR
(BY OTHERS)
FIREPLACE
CONTROL
COMPARTMENT
DUAL SWITCH ELECTRICAL WIRING TO FIREPLACE RECEPTACLE
1. To wire Junction Box Receptacle, remove the tab on the side
of the receptacle (hot side) to split receptacle. This will be
required to separate blower and Accent Light circuits.
2. Power for switched and live sides of Duplex Receptacle must
come from the same power source. (One circuit breaker on
main panel must switch all power off.)
3. From the wall box to the fireplace a 3-wire conductor with
ground is recommended, however (2) two-wire conductors
with grounds may be used in place of a 3-wire conductor with
a ground if the black wires from the Accent Light and blower
accessories are identified.
4. Two wall switches may be used to activate the two receptacle
plugs independently.
24309-1-0908
Note: Wiring to the Junction Box should be run through the 7/8"
diameter access hole located on one of the sides of the fireplace
outer wall. A Romex type connector is provided and should be
used to protect and restrain the wiring where it passes through
the fireplace outer wall. The Junction Box should be positioned in
the lower compartment of the fireplace/firebox so that it does not
interfere with moving parts of the blower assembly. The Junction
Box incorporates magnets on the bottom side to retain and reduce
the chance of movement or vibration during blower operation.
Note: If only the blower option is to be installed, wiring may be
performed as described and illustrated in the following Blower
Installation section.
Page 25
OPTIONAL FBB5 BLOWER INSTALLATION INSTRUCTIONS
Attention: Install blower assembly before connecting gas inlet supply line.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with
a three-prong [grounding] plug for your protection against
shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug. For an ungrounded receptacle,
an adapter, which has two prongs and a wire for grounding, can
be purchased, plugged into the ungrounded receptacle and its wire
connected to the receptacle mounting screw. With this wire completing the ground, the appliance cord plug can be plugged into
the adapter and be electrically grounded.
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
To install the blower kit, access the junction box, or install a light
kit, remove lower louver as illustrated by figure 21.
A factory included junction box is located on the lower right side
of the fireplace. Wiring must be fed through the 7/8" diameter
hole provided on the lower side of the fireplace, and secured to
the outer wrap with the clamp provided. Leave approximately 6”
of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw. See Figure 20.
Install the receptacle into the junction box as illustrated.
Attach cover plate. Place Junction Box so that it is approximately
8 to 12" away from the outer wrap wall. Secure wiring at outer
wrap of fireplace with wire clamp provided.
Attention: If installed, do not damage gas inlet supply line when
blower assembly is inserted into fireplace. In some cases, removal
of the gas inlet supply line may be necessary.
Note: Junction box is to be located in the lower compartment of
the fireplace and must be pre-wired at time of fireplace installation for use with blower assembly. A standard ON/
OFF wall switch or SCV-1 variable speed control kit should
be installed to activate power to the Junction Box and provide power for the operation of the blower assembly. It is
recommended that installation of the wiring be performed
by a qualified electrician. See Figures 20 and 21.
1.
2.
3.
If installed, turn OFF gas supply to fireplace.
If applicable, turn OFF electric supply to fireplace.
Remove bottom louver from fireplace.
CAUTION: ALL WIRING SHOULD BE DONE BY
A QUALIFIED ELECTRICIAN AND SHALL BE IN
COMPLIANCE WITH ALL LOCAL, CITY AND STATE
BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER
SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN
INSTALLED, MUST BE ELECTRICALLY GROUNDED
IN ACCORDANCE WITH LOCAL CODES, WITH THE
NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).
Figure 20
Figure 21
Page 26
24309-1-0908
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)
4. Insert blower assembly into interior, bottom of firebox.
Note: On peninsula models, the blower must be installed at
the end which has the brick panel installed. Position blower
assembly so that you align the notch on back of blower assembly with the center screw on side/end panel, then push
the blower assembly against firebox outer panel. The blower
wheel must be centered with the side/end wall of the firebox.
The magnets on the back and bottom of blower assembly will
sufficiently hold blower assembly in place. See Figure 23.
5. Once the blower assembly is in position, locate the plug button in the top corner of the firebox. Remove the plug with a
standard screwdriver and discard plug.
6. Next, find the fan control switch and wire assembly. Feed the
wires through the hole at the top of the firebox, and secure the
fan control switch with two (2) #6 screws (provided). The fan
control wires will slide down between the firebox and outer
wrap near the blower assembly. See Figure 22.
WIRE ASSEMBLY
FROM FAN
CONTROL SWITCH
FAN
CONTROL
SWITCH
Note: This blower is equipped with a heat activated fan control
switch. Blower will operate when the fireplace warms up,
and will turn off automatically when the fireplace cools
down. The time will vary for the activation of the fan control switch depending on several factors including fireplace
type, BTU input variables, and log set style. Generally, it
may take from 10 to 20 minutes to activate blower/fan control from a cold start.
OUTER
WRAP
JUNCTION
BOX
POWER CORD
BLOWER ASSEMBLY
(CENTER AND INSTALL
AGAINST OUTER WRAP
AS SHOWN)
Figure 23
USE OF A STANDARD
ON/OFF WALL SWITCH TO
OPERATE OPTIONAL BLOWER
Figure 22
7. Route the wires away from moving parts of the blower assembly and retain wires together near the blower motor using
the plastic purse clip provided.
8. To complete the installation, plug the power cord into the
junction box receptacle previously installed in the bottom of
the fireplace. See Figure 23.
9. Once all connections are made electrically, it is recommended that you test the blower fan control operation by turning
on power to the blower (Caution: 110 Volt). Turn the fireplace
on and let run until blower is activated. This should take approximately 10 to 20 minutes from a cold start. Once blower
is activated, check for proper operation. Do not place hands
near blower assembly or other wiring while power is on.
10. Replace louver(s).
11. This completes the installation of the optional FBB5 Blower
kit accessory.
24309-1-0908
Figure 24
Page 27
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, if an external
electrical source is utilized. This appliance is equipped with a
three-prong [grounding] plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug. For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected
to the receptacle mounting screw. With this wire completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to
oil the blower motor.
Blower Wheels
The blower wheels will collect lint and could require periodic
cleaning. If the air output decreases or the noise level increases, it
indicates a dirty blower wheel. Remove blower and clean blower
wheels.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To turn off gas to the unvented heater: Push
in gas control knob slightly and turn clockwise to “OFF.”
Do not force.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
JUNCTION BOX
110 VOLT AC
FAN/MOTOR
ASSEMBLY
BLACK
FAN
SWITCH
WHITE
Figure 25
2
1
A
B
1
2
FBB5
R8199
BLOWER ASSEMBLY COMPLETE
FAN CONTROL SWITCH
Figure 26
Page 28
24309-1-0908
LK2 ACCENT LIGHT ACCESSORY
An Accent Light Kit model LK2 is available for installation
in the top of the firebox. Providing the junction box has been
pre-wired with separate circuits as described in the "Wiring for a
dual switch/receptacle" section.
Follow the instructions provided with the LK2 Accent Light kit
for proper installation in the fireplace.
MAINTENANCE
Keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing area at least twice
a year.
THE LOGS CAN GET VERY HOT - HANDLE ONLY WHEN
COOL.
Never obstruct the flow of the combustion and ventilation air.
Keep the front of the firebox clear of all obstacles and materials.
Screen panels must be in position while fireplace is in operation.
Always turn off gas to the pilot before cleaning. For relighting,
refer to the lighting instructions plate located in the lower compartment near the gas valve.
24309-1-0908
Page 29
PARTS LIST
Attention: When ordering parts, it is very important that part number and description of part coincide.
PART NUMBER
INDEX
NUMBER
VFP36SP32EN
VFP36SP32EP
VFP36PP32EN
VFP36PP32EP
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18a
18b
17301
R3491
R3492
R9719
19401
19945
24115
18807
18808
N/A
N/A
20020
N/A
20143
N/A
10554
P253
P209
-
17301
R3491
R3492
R9719
19401
19945
24115
18807
18808
N/A
N/A
20020
N/A
20143
N/A
10554
P253
P245
17301
R3491
R3492
R9719
19401
19945
24115
18807
18808
24059
24058
20145
24056
20143
24149
10554
P253
P209
-
17301
R3491
R3492
R9719
19401
19945
24115
18807
18808
24059
24058
20145
24056
20143
24149
10554
P253
P245
19a
-
R5675
-
R5675
19b
20a
20b
R5676
R3624
R3623
-
R5676
R3624
R3623
-
21
24756
24515
24756
24515
22
23
24
25
26
R5677
24119
24143
24144
24146
R9692
24119
24143
24144
24146
R5677
24119
24143
24144
24146
R9692
24119
24143
24144
24146
27
N/A
24147
N/A
24147
28
R2423
R2423
R2423
R2423
29
30a
30b
20115
R3626
20115
R3625
-
20115
R3626
20115
R3625
-
DESCRIPTION
TOP STANDOFF
COVER, JUNCTION BOX
RECEPTACLE, 3 PRONG
BRICK LINER
BRICK LINER BRACKET - LOWER
BRICK LINER BRACKET
JUNCTION BOX SUB-ASSEMBLY
LOUVER ASSEMBLY-UPPER
LOUVER ASSEMBLY-LOWER
LOUVER ASSEMBLY-UPPER END
LOUVER ASSEMBLY-LOWER END
HOOD
HOOD - PENINSULA
FRONT FRAME ASSEMBLY
SCREEN FRAME ASSEMBLY - END
NAILING FLANGE
FITTING, ORIFICE ANGLED
ORIFICE #31 (NAT)
ORIFICE #50 (LP)
AIR SHUTTER-FULLY OPEN
(LP ONLY)
AIR SHUTTER (NAT UNITS)
PILOT ASSEMBLY LP
PILOT ASSEMBLY NAT
BURNER SUB ASSEMBLY
(INCLUDES #22)
TUBE, VENTURI ASSEMBLY
BURNER BASE
BURNER SUPPORT
GRATE ASSEMBLY
TUBING ASSEMBLY, INLET
TUBING ASSEMBLY, PILOT
(LP ONLY)
CONNECTOR, MALE
5/16 X 3/8 NPT
VALVE BRACKET
VALVE, LPG
VALVE, NAT
Use Only Manufacturer's Replacement Parts. Use of Any Other Parts Could Cause Injury Or
Death.
nOTE: sEE LOG INSTRUCTION MANUAL FOR DETAILS ON LOGS AND EMBERS
Page 30
24309-1-0908
PARTS LIST
Attention: When ordering parts, it is very important that part number and description of part coincide.
PART NUMBER
INDEX
NUMBER
VFP36SP32EN
VFP36SP32EP
VFP36PP32EN
VFP36PP32EP
31
32
33
34
23244
R3435
R3436
R2313
23244
R3435
R3436
R2313
23244
R3435
R3436
R2313
23244
R3435
R3436
R2313
35
24148
-
24148
-
36
37
38
39
R7063
20116
R7591
15999
R7591
15999
R7063
20116
R7591
15999
R7591
15999
40
-
24675
-
24675
41
-
24676
-
24676
42
43
44
45
46
47
NOT SHOWN
NOT SHOWN
R2792
24291
24661
24664
24662
24663
11788
M162
R2792
11788
M162
R2792
24291
24661
24664
24662
24663
11788
M162
R2792
11788
M162
DESCRIPTION
VENTURI SHIELD
WIRE ASSEMBLY
SWITCH, REMOTE/OFF/ON
IGNITER, PIEZO W/BLACK
TUBING ASSEMBLY, PILOT TO
REGULATOR (NAT ONLY)
REGULATOR, PILOT (NAT ONLY)
TUBING ASSEMBLY (NAT ONLY)
FLEXLINE 3/8” X 12”
ROCKWOOL .165 - .175 OZ
BRACKET, LOG SUPPORT (REAR)
(LP)
BRACKET, LOG SUPPORT
(FRONT) (LP)
WIRE IGNITOR 22”
LOG SPACER PLATE
LOG SUPPORT (2)
LOG SUPPORT
LOG SUPPORT
LOG SUPPORT
DECORATIVE ROCK (2.25 LB)
VENTURI GASKET
See page 32 for See-Through models VFP36SP series Parts View for ordering parts.
See page 33 for Peninsula models VFP36PP series Parts View for ordering parts.
Use Only Manufacturer's Replacement Parts. Use of Any Other Parts Could Cause Injury Or
Death.
nOTE: sEE LOG INSTRUCTION MANUAL FOR DETAILS ON LOGS AND Rockwool.
HOW TO ORDER REPAIR PARTS
Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts
through the distributor. Parts can be shipped directly to the service person/dealer.
All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate
illustration and list. Be sure to give all this information.
Fireplace Model Number
Part Description
Fireplace Serial Number
Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, fires and all causes beyond our control.
24309-1-0908
Page 31
SEE-THROUGH FIREPLACE PARTS VIEW
1
6
8
4
12
16
14
5
6
9
8
12
4
5
14
7
3
9
2
17 18 19
22 31
24
41
40
25
21
20
44
45
44
43
42
25
26
27
28
23
30
Nat G
29
as
Page 32
47
24
32
35
46
36 37
34
38
21
NAT. BURNER
39
33
24309-1-0908
PENINSULA FIREPLACE PARTS VIEW
6
1
4
8
12
16
5
14
10
8
12
14
15
11
9
17 18 19
22
24
7
3
2
31
41
40
42
25
44
21
20
46
44
43
25
47
24
26
27
28
23
30
Nat G
29
as
35
45
LP BURNER
32
24309-1-0908
9
13
36 37
34
38
21
NAT. BURNER
39
33
Page 33
ACCESSORIES
Accessory
Fan Kit
Description
Model Numbers
2
1
Designed to provide forced air flow.
FBB5
Wall mounted variable speed control for use with
FBB5 blower
SCV-1
Variable Speed Control Kit
Frame Kits
Standard 3-Piece Frame Kits
Black, Brass, Stainless Steel, or Hammered Pewter
Extruded Aluminum Frame Kits
Black, Brass, Stainless Steel, or Hammered Pewter
For use with See-Through models:
VFP36SP32 SERIES ONLY
Contact dealer for all available
optional frame kits
Bottom Trim Strip
Available as optional kits in Black, Brass, Hammered Pewter, and Stainless Steel finishes.
Standard Hood
For VFP36SP32 SERIES ONLY
Contact dealer for all available
optional trim accessories
Brass hood = BR
Stainless Steel = SS
Contact dealer for all available
optional hood accessories
Hammered Pewter = HP
Page 34
24309-1-0908
ACCESSORIES (continued)
Accessory
Accent Light Kit
Description
Optional light kit that installs in top of firebox to enhance
logset. Operates with a Rheostat control to vary brightness
of light for desired effect.
Extended 4" Hoods
Model Numbers
LK2
Extended hoods that extend out 2" farther than the standard hoods, to accommodate thicker surround materials.
Available as optional kits in Black, Brass, Hammered
Pewter, and Stainless Steel finishes.
Contact dealer for all available
optional hood accessories
Note: Not available for Peninsula open ends.
Louvers
Styles include Slat, Mission, Arch, and Leaf Patterns.
Available as optional kits in Black, Brass, Hammered
Pewter, and Stainless Steel finishes.
Decorative Door Kits
Available as optional kits in Black, Brass, Hammered
Pewter, and Stainless Steel finishes.
Decorative Frame Kits
Available as optional kits in Black, Brass, Hammered
Pewter, and Stainless Steel finishes.
Mantel Systems
24309-1-0908
Available in various styles and finishes.
Contact dealer for all available
optional louver accessories
Contact dealer for all available
optional door kit accessories
Contact dealer for all available
optional decorative frame kit
accessories
Contact dealer for all available
mantel options.
Page 35
SERVICE NOTES
Page 36
24309-1-0908
Web Site: www.empirecomfort.com
Empire Comfort Systems
918 Freeburg Avenue
Belleville, Illinois 62220-2623
The Vail Premium Vent-Free Fireplaces
GAS-FIRED
SEE-THROUGH FIREPLACE MODELS:
VFP36SP32EN-1
VFP36SP32EP-1
PENINSULA FIREPLACE MODELS:
VFP36PP32EN-1
VFP36PP32EP-1
36-inch Fireplace accommodates the following Log Set:
Refractory Log Set:
LSU-24RR-2
Banded Brick Liners are made from Ceramic Fiber for rich detail and lasting beauty. Banded Brick
Liners have dark "creamed-coffee" bricks with charcoal mortar in running bond courses, plus an
accent band of diagonal bricks.
2 9/16”
2 9/16”
2 9/16”
G
C
SEE THRU
LOUVERED
PENINSULA
LOUVERED
DMN AH
F
F
K
DMN AH
K
J
J
L
I
E
B
L
E
B
VFP36SP
24309-1-0908
I
VFP36PP
A
34 3/4”
H
37 3/4”
A
34 3/4”
H
37 3/4”
B
39”
I
1 1/4”
B
39”
I
1 1/4”
C
24”
J
6 1/8”
C
24”
J
6 1/8”
D
22”
K
2 1/2”
D
22”
K
2 1/2”
E
36”
L
5”
E
36”
L
5”
F
34 1/4”
M
24 1/8”
F
35 1/4”
M
24 1/8”
G
29 1/8”
N
33 1/2”
G
29 1/8”
N
33 1/2”
Page 37
Empire Comfort Systems
918 Freeburg Avenue
Belleville, Illinois 62220-2623
Web Site: www.empirecomfort.com
The Vail Premium Vent-Free Fireplaces
SEE-THROUGH FIREPLACE MODELS:
PENINSULA FIREPLACE MODELS:
VFP36SP32EN-1
VFP36PP32EN-1
VFP36SP32EP-1
VFP36PP32EP-1
Clearances
Combustible material clearance (furniture, parallel walls) from front of fireplace: 36" minimum
Sidewall Clearances: The clearance from the inside opening of the firebox to perpendicular combustible side wall
should not be less than 1 3/4".
Firebox Side and Back Clearances: The fireplace outer casing side(s) require a minimum 1/2" clearance to
combustibles.
Top Framing and Finishing: Combustible framing may rest on top of standoffs. Combustible finishing materials may
extend to the top standoff screws on the front edge of the top outer wrap.
Ceiling Clearances: The ceiling height should not be less than 42" from the top of the hood.
Mantel Clearances: Vent free fireplace models must use the hood supplied with the fireplace, or one of the optional
hood kits available for each model. If a combustible mantel is installed, it must meet the clearance requirements
detailed below.
CEILING
CEILING
12”
MAX
10”
12”
MAX
10”
MANTEL
MANTEL
42”
MIN.
(CEILING TO
TOP OF HOOD)
COMBUSTIBLES
ALLOWED
8”
15”
24 ½”
42”
MIN.
(CEILING TO
TOP OF HOOD)
22”
20”
6 ½”
13”
17 ½”
5”
18”
5”
84”
MIN.
(CEILING TO FLOOR)
8” COMBUSTIBLES
ALLOWED
6 ½”
3 ½”
13”
11”
3 ½”
9”
16”
84”
MIN.
(CEILING TO FLOOR)
2 ½”
14 ½”
1 ½”
6 ½”
8”
MIN.
4 ½”
MIN.
0”
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
STANDARD
OF FIREBOX
HOOD
FIREBOX
FACE
0”
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
EXTENDED HOOD
(VB4H SERIES)
(NOT AVAILABLE ON
PENINSULA OPEN END)
FIREBOX
FACE
Mantel Clearances with Standard Hood
Page 38
Mantel Clearances with Optional Extended Hood
24309-1-0908
Web Site: www.empirecomfort.com
Empire Comfort Systems
918 Freeburg Avenue
Belleville, Illinois 62220-2623
The Vail Premium Vent-Free Fireplaces
SEE-THROUGH FIREPLACE MODELS:
PENINSULA FIREPLACE MODELS:
VFP36SP32EN-1
VFP36PP32EN-1
VFP36SP32EP-1
VFP36PP32EP-1
Clearances (continued)
1 3/4” MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
Framing
42”
MIN.
(CEILING TO
TOP OF HOOD)
A
C
B
Framing - Peninsula
36”
MIN.
See Through Fireplace Clearances
A
C
1 3/4” MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
B
42”
MIN.
(CEILING TO
TOP OF HOOD)
Framing - See-Through
Premium Vent-Free Fireplace Framing Dimensions (inches)
Model
36”
MIN.
Peninsula Fireplace Clearances
24309-1-0908
"A"
"B"
"C"*
Framing Height
Framing Width
Framing
Depth
VFP36SP
41 1/2"
40"
23"*
VFP36PP
41 1/2"
39"**
23"*
Attention: Add height of base to "A" Dimension when elevating fireplace if installing on an elevated base.
Framing dimension A incudes a three inch clearance for standoffs
on fireplace.
*
Dimension "C" assumes use of 1/2" wall board flush to both front
faces.
** Peninsula model framing width assumes use of 1/2" wall board
flush to the end face.