ESI Communications Servers
ESI-1000 • ESI-600 • ESI-200 • ESI-100 • ESI-50
Hardware Installation Manual
0450-1049
Rev. R
Copyright © 2011 ESI (Estech Systems, Inc.).
IVX is a registered trademark of Estech Systems, Inc. Ethernet is a registered trademark of
Xerox Corporation. Motorola and ColdFire are registered trademarks of Motorola, Inc. Rayovac is a
registered trademark of Rayovac Corporation. Act! is a registered trademark of Symantec
Corporation. Goldmine is a trademark of Goldmine Software Corporation. Microsoft, Windows, NT
and Outlook are registered trademarks of Microsoft Corporation. Panasonic and DBS are registered
trademarks of Matsushita Electric Corporation of America. Novell and Netware are registered
trademarks of Novell, Inc. Smart Jack is a trademark of Westell Technologies, Inc. Information
contained herein is subject to change without notice. Certain features described herein may not be
available at initial release. ESI products are protected by various U.S. Patents, granted and pending.
Visit ESI on the Web at www.esi-estech.com.
Contents
Overview........................................................................A.1
Hardware installation: ESI-50...................................... H.1
Cabinet components.............................................................. A.1
Base Cabinet ......................................................................... A.1
Expansion Cabinets............................................................... A.2
Main board............................................................................. A.2
Backplane.............................................................................. A.2
Memory Module..................................................................... A.3
Power supply ......................................................................... A.3
Port card options.................................................................... A.4
NSP ....................................................................................... A.7
Site location............................................................................H.1
Opening the Base Cabinet .....................................................H.2
Mounting the Base Cabinet ....................................................H.2
Expansion Cabinet installation................................................H.3
Port card installation...............................................................H.3
Memory Module installation or replacement ...........................H.5
LED functions.........................................................................H.6
ESI Presence Management installation..................................H.7
ESI Cellular Management installation.....................................H.7
Installation of card(s) for ESI Mobile Messaging and SIP trunking
............................................................................................H.8
Installation of Memory Module for CS-ASC ............................H.9
Phones...........................................................................B.1
Digital phone models ............................................................. B.1
IP phone models.................................................................... B.2
ESI Cordless Handsets.......................................................... B.3
Expansion Consoles .............................................................. B.4
Phone overlays ...................................................................... B.4
VIP Softphone........................................................................ B.4
Licensing .......................................................................C.1
System capacities.........................................................D.1
Cautions and regulatory information.......................... E.1
Cautions ................................................................................ E.1
Regulatory information........................................................... E.2
Hardware installation: ESI-1000, ESI-600, ESI-200 .... F.1
Site location ............................................................................F.1
Mounting the cabinet(s)...........................................................F.1
Expansion Cabinet installation ................................................F.2
Port card installation................................................................F.2
About replacing port cards ......................................................F.4
Memory Module installation or replacement............................F.5
Removing the Memory Module from the main board..............F.8
Mirrored Memory Module........................................................F.9
LED functions .......................................................................F.15
ESI Presence Management installation ................................F.16
ESI Cellular Management installation....................................F.16
Installation of card(s) for ESI Mobile Messaging and SIP trunking
..........................................................................................F.17
Installation of Memory Module for CS-ASC...........................F.18
External connections..................................................... I.1
Grounding instructions ............................................................ I.1
Power...................................................................................... I.1
MOH port ................................................................................ I.3
Maintenance/SMDR serial port................................................ I.3
External paging device connection.......................................... I.4
Amphenol cable connections................................................... I.4
CO line connection.................................................................. I.5
Station connection................................................................... I.7
60-Key Expansion Console connection................................... I.8
60-Key Second Expansion Console connection...................... I.9
Installing ESI’s Cordless Handsets........................................ I.10
Port card connections............................................................ I.13
Cabinet worksheets............................................................... I.23
Ordering and installing PRI circuits............................ J.1
PRI configuration description.................................................. J.1
Index
Hardware installation: ESI-100 ....................................G.1
Site location ...........................................................................G.1
Opening the Base Cabinet.....................................................G.2
Mounting the Base Cabinet....................................................G.2
Expansion Cabinet installation ...............................................G.3
Port card installation...............................................................G.3
Memory Module installation or replacement...........................G.5
LED functions ........................................................................G.6
ESI Presence Management installation .................................G.7
ESI Cellular Management installation.....................................G.7
Installation of card(s) for ESI Mobile Messaging and SIP trunking
...........................................................................................G.8
Installation of Memory Module for CS-ASC..........................G.10
Important: For information concerning the programming of an ESI Communications Server (the ESI-1000,
ESI-600, ESI-200, ESI-100, or ESI-50), see the ESI Communications Servers Programming Manual
(ESI document # 0450-1050).
Statements in this document about ESI Communications Servers as a group do NOT pertain to the
ESI-50L, which must be upgraded to ESI-50 status to provide a number of usual ESI Communications
Server features (particularly those related to automatic call distribution, IP capabilities, and use of PRI).
For information concerning hardware installation of the the ESI-50L, please see the ESI-50L Hardware
Installation Manual (ESI document # 0450-1159).
The 48-Key Feature Phone has a dedicated PROGRAM key. If using a 48-Key Feature Phone,
(a.) press PROGRAM wherever the instructions tell you to press PROG/HELP to access programming.
and (b.) press HELP wherever the instructions tell you to press PROG/HELP to access the Verbal
User’s Guide.
ESI Communications Servers Hardware Installation Manual
Overview
Overview
Cabinet components
ESI-1000, ESI-600, and ESI-200
1
Cabinet components for the ESI-1000, ESI-600, and ESI-200 consist of:
•
Base Cabinet
– Main board
– Backplane
– Memory Module
– Seven port card slots
– External wall-mounted power supply
•
Expansion Cabinet (optional)
– Backplane
– Seven port card slots
– Expansion cable
– Expansion Card
– External wall-mounted power supply
•
Expansion Cabinet (optional)
– Two port card slots
•
Expansion Cabinet (optional)
– Two port card slots
ESI-100
1
The ESI-100’s cabinet components consist of:
•
Base Cabinet
– Main board
– Memory Module
– Two port card slots
– External wall-mounted power supply
ESI-50
1
The ESI-50’s cabinet components consist of:
•
Base Cabinet
– Main board with built-in 482 and
SL-IVC 12 port cards
– Memory Module
– One port card slot
– External wall-mounted power supply
Base Cabinet
The ESI Communications Server Base Cabinet is designed for easy installation and component access.
Regardless of model, each ESI Communications Server Base Cabinet houses the main board, Memory Module,
Network Services Processor (NSP), one multi-purpose serial port, and an MOH connector.
ESI-1000, ESI-600, and ESI-200
The Base Cabinet for the ESI-1000, ESI-600, and ESI-200, which measures 19″ W 10.5″ H 10.5″ D, also
2
houses the Mirrored Memory Module (M3) and seven port card slots (see “Port card options,” page A.4).
ESI-100
The Base Cabinet for the ESI-100, which measures 8.5″ W 11″ H 3″ D, also houses two port card slots
(see “Port card options,” page A.4).
ESI-50
The Base Cabinet for the ESI-50, which measures 8.5″ W 11″ H 3″ D, has a main board with built-in 482
and IVC 12 port cards. it also houses an additional port card slot (see “Port card options,” page A.4).
1
2
Memory Modules and port cards are packaged separately and are mounted in each system’s cabinet during installation.
The M3 interface is standard on the ESI-1000, optional on the ESI-600 and hard drive-equipped ESI-200. Each requires an optional second
Memory Module.
A.1
ESI Communications Servers Hardware Installation Manual
Overview
Expansion Cabinets
Each ESI Communications Server can be expanded to increase the number of port cards. The ESI-1000 and
ESI-600 each accept the same Expansion Cabinet, while the ESI-200, ESI-100, and ESI-50 have their own
unique Expansion Cabinets.
System
ESI-1000
ESI-600
ESI-200
ESI-100
ESI-50
Maximum
Expansion Cabinets
5
3
1
1
1
Maximum port cards
per Expansion Cabinet
7
7
7
2
2
Total system capacity
(port cards)
42
28
14
4
3 (plus a built-in 482 and IVC 12)
Main board
®
®
The main board combines leading-edge hardware components — including a Motorola ColdFire processor
and DSP structure — along with proprietary operating system software. The board provides: system control of
the Memory Module and port cards; a standard RS-232C DB9 serial port; a built-in modem for remote access;
an external paging-device interface; MOH interface; an NSP, which provides remote access via TCP/IP and
supports certain optional ESI PC software applications; and (except on the ESI-100 and ESI-50) a mount for the
1
Mirrored Memory Module.
Backplane
On the ESI-1000, ESI-600, and ESI-200, each cabinet (Base or Expansion) is equipped with a backplane that
supports up to seven port cards.
1
The M3 interface is standard on the ESI-1000, optional on the ESI-600 and hard drive-equipped ESI-200. Each requires an optional second
Memory Module.
A.2
ESI Communications Servers Hardware Installation Manual
Overview
Memory Module
®
The Memory Module — a hard disk drive or CompactFlash with proprietary formatting — contains all system
programming and configuration data, and pre-loaded voice prompts. The Memory Module provides voice
storage at 64 kilobits per second — the industry's highest-quality sampling rate. Here are the capacities by
system model:
Memory Module type
CompactFlash
Hard-disk drive
ESI-1000
n/a
1,200-hr.
ESI-600
n/a
1,200-hr.
ESI-200
140-hr.
600-hr.
ESI-100
140-hr.
n/a
ESI-50
15-hr. and 60-hr.
n/a
Optional Mirrored Memory Module (M3)
Note: Not available on the ESI-200 with CompactFlash, ESI-100, or ESI-50.
Using RAID-1 hard drive technology, the optional Mirrored Memory Module (M3) maintains system operation
on a separate disk drive in the event of a hard drive failure. M3 is required when redundancy of system
programming, speed-dial entries, and voice mail messages and prompts is desired.
Note: M3 use on the ESI-200 requires that both Memory Modules be the 600-hour (hard-disk drive) model.
Power supply
All power supplies are included at purchase.
•
ESI-1000, ESI-600, or ESI-200 — Uses a 7.5-amp, 24 VAC power supply on the Base Cabinet and each
Expansion Cabinet.
•
•
ESI-100 — Uses a 5-amp, 24 VAC power supply.
ESI-50 — Uses a 3-amp, 24 VAC power supply.
Optional rack-mount Power Distribution Shelf
The optional Power Distribution Shelf can be mounted in a standard 19-inch rack. Each Power Distribution
Shelf, which can hold up to four power supplies, includes a six-outlet power strip with on/off switch and 15'
power cord.
A.3
ESI Communications Servers Hardware Installation Manual
Overview
Port card options
ESI Communications Servers support a wide range of port cards. Any E2 port card can be used on any ESI
1
Communications Server with the use of an additional E2 Port Card “Hot Swap” Adapter (except on the ESI-100).
The CS port cards (used with the ESI-1000, ESI-600, and ESI-200) are full-size cards with built-in “hot-swap”
capability, along with a special “ejector-handle” mechanism that makes them literally a snap to install or uninstall.
The following port cards are supported:
Ports
2
Port card
COs
Stations
CS-684
CS-612
CS-6ALC
CS-A12
CS-D12
6
6
6
8 digital
12 digital
CS-DLC12
CS-DLC
CS-IVC 24R
CS-IVC 24EL
CS-IVC 12R12EL
E2-684
E2-612
ESI-6ALC
3
E2-A4
E2-A12
E2-D12
E2-DLC12
ESI-DLC
12
24 (T1)
or 23B +1D (PRI)
24 (T1)
or 23B +1D (PRI)
12 digital
6
6
6
6
3
10
6
3
12 digital
34
4
4
42
42
42
32
32
42
17
2
2
28
28
28
15
15
28
8
1
1
14
14
14
4
4
14
4
4
4
2
2
4
12 digital
10
6
3
1
10
6
3
1
34
4
4
17
2
2
8
1
1
3
1
1
24
12
12 IP
8 digital
12 digital
4
4
12
24 (T1)
or 23B +1D (PRI)
24 (T1)
or 23B +1D (PRI)
24 IP
23B +1D (PRI)
4
System maximums (port cards)
ESIESIESIESIESI1000
600
200
100
50
42
28
14
42
28
14
42
28
14
32
15
4
42
28
14
10
24 IP
SL-IVC 12
CS-SIP24
CS-SIP8
CS-ASC
Esi-Link
channels
12 digital
4
IVC 24R
IVC 24EL
IVC 12R12EL
SL-DLC82
482
Analog
stations
4
24
12
12 IP
8 digital
8 digital
12 local IP or
8 remote IP
2
2
1
5
4
6
1
8
24
8
10
10
20
6
6
14
3
3
7
1
1
1
The cards are described beginning on the next page.
Warning: Any port card shipped prior to March 16, 2007, will NOT boot on the second cabinet of an ESI-200.
However, these cards can be updated. For details and the update procedure, see Technical Update 264,
available from www.esi-estech.com/Resellers/tech.
1
2
3
4
5
6
See “Hot-swap operations,” page A.7.
For each IVC, the quantity of IP stations is a combination of locally and remotely installed IP phones.
Not supported on the ESI-50 (or ESI-50L).
Previously called IVCR24.
One of the four 482 cards is built-in (ESI-50 only).
Built into the main board (ESI-50 only); see also “Port card descriptions,” page A.5.
A.4
1
1
1
ESI Communications Servers Hardware Installation Manual
Overview
Port card descriptions
• CS-684, E2-684 — Connects up to six analog loop-start CO lines, eight ESI digital phones, and four
analog station ports. The CO line ports support standard CO and Centrex loop-start lines (but not groundstart CO lines). The analog ports provide a standard 24-volt, two-wire connection to fax machines,
courtesy phones, modems, etc. Only one device can be connected to each analog station port. This card
uses 12 station ports and six CO ports.
• CS-612, E2-612 — Provides circuits to connect up to six analog loop-start CO lines and 12 ESI digital
phones. Ground-start CO lines are not supported. This card uses 12 station ports and six CO ports.
• CS-6ALC, ESI-6ALC — Similar to the CS-612 and E2-612, but connects only up to six analog loop-start
CO lines (and no stations).
• E2-A41 — Connects up to four analog devices (only), such as fax machines and cordless phones. This card
uses four station ports and no CO ports. Each port provides a standard 24-volt, two-wire phone
connection. Only one analog device can be connected to each port.
• CS-A12, E2-A12 — Connects up to 12 analog devices (only), such as fax machines and cordless phones.
This card uses 12 station ports and no CO ports. Each port provides a standard 24-volt, two-wire phone
connection. Only one analog device can be connected to each port.
• CS-D12, E2-D12 — Connects up to 12 ESI digital phones (only). This card uses 12 station ports and
no CO ports.
• CS-DLC12, E2-DLC12 (Digital Line Card) — Provides either a T1 interface supporting 24 DS0 channels
and 12 digital stations or an ISDN PRI interface supporting 23 B (bearer) channels, one D (datalink)
channel, and 12 digital stations.
A jumper on this card must be plugged onto pins 7 and 8 of J3 to enable ISDN PRI functions. Any
(or all) of the available channels of the T1/PRI span (24 on T1, 23 on PRI) can be assigned, and the card
supports loop-start, ground-start, E&M and DNIS/DID trunk types with immediate, wink-start or dial-tonestart signaling. This card is equipped with a built-in CSU that can be connected directly to a network
interface unit, SmartJack, or ISDN PRI. Up to 12 ESi digital phones can be connected to the card.
All 24 CO ports are allocated (regardless of whether they are assigned or used).
• CS-DLC, ESI-DLC — Similar to the CS-DLC12 and E2-DLC12, but supports only a T1 or PRI circuit (and
no phones).
• CS-IVC, IVC (Intelligent VoIP Card) — Supports standards-compliant IP telephony service and features,
including VoIP to the desktop and Esi-Link. It features highly configurable DSP technology that manages
the flow of traffic among the port cards and converts IP packets into PCM (pulse-code modulation) traffic
®
for transmission over the PSTN. The physical connection is a 10/100Base-T, RJ-45 Ethernet interface
that allows the system to connect to an IP-based local area network (LAN).
The IVC is offered in three versions:
2
• IVC 24R — Provides 24 IP stations (local or remote).
• IVC 24EL — Provides 24 channels for Esi-Link.
• IVC 12R12EL — Provides 12 IP stations (local or remote) and 12 Esi-Link channels; does not
support SIP phones.
Each ESI Communications Server model has a specific maximum of each type of IVC (see the table
on page A.4). The system automatically designates the first IVC station card (lowest-numbered slot) as
the primary IVC — which acts as the “master” that, when an IP Phone first comes on line, identifies the
IVC station card to which the ESI IP phone connects (IVC Esi-Link cards are excluded from this
operation). Licensing is required to support each ESI IP phone or SIP phone. The following table shows
the maximum number of ESI IP phones and Esi-Link channels for each system.
Maximums
IP stations
Esi-Link channels
ESI-1000
816
96
(Continued)
1
2
3
Not supported on the ESI-50 (or ESI-50L).
SIP phones are supported on only the IVC 24R.
With (E2) IVC 24EL.
A.5
ESI-600
408
48
ESI-200
192
24
ESI-100
72
3
24
ESI Communications Servers Hardware Installation Manual
Overview
• SL-DLC82 — (ESI-50 only.) Provides an ISDN PRI interface supporting 23 B (bearer) channels, one D
(datalink) channel, eight digital stations, and two analog devices.
A jumper on this card must be plugged onto pins 7 and 8 of J3 to enable ISDN PRI functions.
Any (or all) of the 23 available channels of the PRI span can be assigned, and the card supports loop-start,
ground-start, E&M and DNIS/DID trunk types with immediate, wink-start or dial-tone-start signaling.
This card is equipped with a built-in CSU that can be connected directly to a network interface unit,
SmartJack, or ISDN PRI. Up to eight ESI digital phones and up to two analog phones can be connected
to the card. All 24 CO ports are allocated (regardless of whether they are assigned or used).
• 482 — (ESI-50 [and ESI-50L] only.1) Provides circuits to connect up to four loop-start CO lines, eight ESI
digital phones, and two analog station ports. The CO line ports support standard CO and Centrex loopstart lines; ground-start CO lines are not supported. Only one analog device can be connected to each
analog station port. This card uses 10 station ports and four CO ports when installed.
Notes: The main board comes in a four-line, eight-digital station, two-analog port configuration. You can add
three 482 port cards on an ESI-50. Therefore, the system can have the following configurations.
— 4 8 2: Base Cabinet (main board only)
— 8 16 4: Base Cabinet with one additional 482 port card.
— 12 24 6: Base Cabinet with one additional 482 port card and an Expansion Cabinet
with one 482 port card.
— 16 32 8: Base Cabinet with one additional 482 port card and an Expansion Cabinet with
two 482 port cards.
The maximum ESI-50 configuration — if an SL-DLC82 is used in slot 2 and the built-in IVC (see next
item) uses all 12 local IP channels — is 35 x 44 x 8.
• SL-IVC 12 — (ESI-50 only.) The ESI-50’s built-in SL-IVC 12 can support up to 12 IP channels, which support
up to 12 local IP stations, or up to eight remote IP channels. Local IP, remote IP, and Esi-Link channels
can be used in various combinations, which are activated in blocks of four for local IP, singles for remote IP,
and blocks of four for Esi-Link. Here is an example of some possible IVC 12 channel combinations:
–
–
–
–
Eight all Esi-Link.
12 all local IP.
Eight Esi-Link, four local IP.
Four Esi-Link, four local IP, four remote IP.
Important: The SL-IVC 12 is part of the ESI-50 main board; it is not available as an add-on port card.
• CS-SIP24 — Provides 24 SIP trunk ports and supports ESI Mobile Messaging delivery of .WAV files to
e-mail addresses.
• CS-SIP8 — Provides eight SIP trunk ports and supports ESI Mobile Messaging delivery of .WAV files to
e-mail addresses.
• CS-ASC (Application Services Card) — Supports ESI Mobile Messaging delivery of .WAV files to
e-mail addresses. Also supports the storage of video recordings, audio recordings, SMDR records, and
fob events.
1
The 482 card also is used by ESI’s C-Plus and IVX S-Class (Generations I–II) systems.
A.6
ESI Communications Servers Hardware Installation Manual
Overview
Hot-swap operations
“CS” port cards — full-sized cards for use on only the ESI-1000, ESI-600, and ESI-200 — have built-in
hot-swap capability, allowing you to replace them while the system is powered-up.
For hot-swap capability, an “E2” port card must be mounted onto a “Hot Swap” Port Card Adapter (ESI part
#5000-0462) prior to being installed on the ESI-1000, ESI-600, or ESI-200. However, installing a new port
card requires power-cycling the system to allow it to recognize the new card.
The following rules apply to hot-swap operations on ESI Communications Servers:
• The ESI-100 and ESI-50 do not support hot-swapping; this capability is available on only the ESI-1000,
ESI-600, and ESI-200.
• When you replace a port card with a new one, the system will detect the port card type.
• If the new port card’s type is different than that of the original port card, the newly installed port card
won’t come on-line.
• If the new port card’s type is the same as that of the original port card, the system will automatically
upload software to the new port card. This upload process can take from four minutes to one hour,
depending on the type of port card and how busy the system is at the time.
For details, refer to the procedure in “About replacing port cards,” page F.4.
NSP
Built into the main board, the NSP (Network Services Processor) serves as a bridge between an Ethernet-based
network and the ESI Communications Server. Using TCP/IP, the NSP communicates directly with specific PC
applications for maintenance of, and integration with, the ESI system. The NSP manages optional features such as
VIP and phone control via TAPI PC applications; it also provides access to not only maintenance and administration
(through use of ESI System Programmer software) but also an Installer-selectable SMDR interface.
The NSP hardware interface consists of a dedicated Ethernet port. Its external RJ-45 jack provides a
10/100Base-T connection to the LAN. The NSP consumes no call-processing ports.
Note: The ESI-50 provides one Ethernet port for access to the NSP and built-in IVC12.
A.7
ESI Communications Servers Hardware Installation Manual
Phones
Phones
Digital phone models
An ESI Communications Server supports several different models of ESI digital phones, each of which
connects to the cabinet via standard two-wire twisted pair.
Current models
• ESI 60 (digital version) — Three-line, 56-character display; speakerphone; headset jack; 48 programmable
feature keys; supports VIP and the 60-Key Expansion Consoles. Available with full-duplex speakerphone
and display with adjustable backlighting.
• ESI 40 (digital version) — Three-line, 56-character display (adjustable backlit display available);
speakerphone; headset jack; 16 programmable feature keys; supports VIP and the 60-Key
Expansion Consoles.
• 48-Key Digital Feature Phone — Three-line, 56-character display; speakerphone; headset jack1;
30 programmable feature keys; supports VIP and the 60-Key Expansion Consoles.
Note: Not all modular headsets will work on the 48-Key Feature Phone’s headset jack. ESI has tested and
can recommend the following headset models:
Manufacturer: Plantronics
— P51-U10P sound tube microphone
— P51N-U10P noise-cancelling microphone
— P251-U10P sound tube microphone
— P251N-U10P noise-cancelling microphone
Manufacturer: GN Netcom
— GN2120 NCD 01 “over-the-head”
— GN2127 NCD 01 “on-the-ear”
Note that GN Netcom models also are available in a “-02” configuration, which wires differently and
won’t work with ESI phones. Therefore, when ordering GN Netcom headsets for use with ESI
phones, be sure to specify the “-01” configuration.
• 24-Key Digital Feature Phone — Two-line, 32-character display (backlit display available);
speakerphone; 12 programmable feature keys.
• Cordless Handset II — DECT 6.0 technology (including use of optional Repeater to extend range);
two-line, 32-character display; speakerphone; eight programmable feature keys.
Legacy models
• 12-Key Digital Feature Phone — One-line, 16-character display; nine programmable feature keys.
• [Original] Cordless Handset — Two sizes; two-line, 32-character display; four programmable feature keys.
Note: When a desktop phone is in the highest upright position, use the wall-mount hook located under the handset
to secure the handset when you’re not using the phone.
1
Headset jack only on 48-Key Feature Phones (Digital, Digital TAPI, [local] IP, or Remote IP) manufactured after March, 2004.
B.1
ESI Communications Servers Hardware Installation Manual
Phones
IP phone models
Note: For information concerning Cordless Handset models, see “ESI Cordless Handsets” (page B.3).
Current models
• ESI 60 (IP versions) — 10/100 or Gigabit Ethernet. Three-line, 56-character display (adjustable backlit
display available); speakerphone; headset jack; 48 programmable feature keys; supports VIP and the
60-Key Expansion Consoles.
• ESI 40 (IP version) — 10/100 Ethernet. Three-line, 56-character display (adjustable backlit display
available); speakerphone; headset jack; 16 programmable feature keys; supports VIP and the 60-Key
Expansion Consoles.
• 48-Key IP Feature Phone II — Three-line, 56-character display; speakerphone; headset jack;
30 programmable feature keys; supports VIP and the 60-Key Expansion Consoles.
• Remote IP Cordless Handset II and Local IP Cordless Handset II.
Legacy models
• Remote IP [original] Cordless Handset and Local IP [original] Cordless Handset.
Features and support for standards
An ESI desktop IP phone looks and works like a regular digital phone as described on page B.1, but connects
from within the local premises via an IP local area network (LAN) rather than twisted-pair cabling. If used onpremises, an ESI IP phone derives its operating power directly over the LAN from Power over Ethernet
(PoE). If used remotely, an ESI desktop IP phone connects to the cabinet from a remote location via an IP
network (either a WAN or the public Internet). Each ESI desktop IP phone derives its power from an individual
Power over Ethernet (PoE) adapter. An ESI desktop IP phone supports the following features and standards:
•
•
•
•
IEEE 802.3af Power over Ethernet (PoE).
Power via PoE.
Can be configured for either local or remote (off-site) operation.
Uses a G.711 codec in its “local” mode of operation and a G.726 codec in its “remote” mode. In G.711
mode, the transfer rate is 206 Kbps; in G.726 mode, the transfer rate is 90 Kbps.
• Can use DHCP1 to obtain an IP address:
– In “local” operation, DHCP can be enabled or disabled2 for the ESI desktop IP phones on each IVC.
Alternatively, a “static” IP address may be assigned by the Installer (in Function 31; see the ESI
Communications Servers Programming Manual, ESI document #0450-1050).
– In “remote” operation, an ESI desktop IP phone automatically uses DHCP to obtain an IP address and
default gateway.
(Continued)
1
2
Dynamic Host Configuration Protocol, an IP standard described in RFC 2131 (http://www.ietf.org/rfc/rfc2131.txt).
Default setting for DHCP is disabled.
B.2
ESI Communications Servers Hardware Installation Manual
Phones
• Complies with IEEE 802.1q and 802.1p (VLAN) Layer 2 switching and prioritization.
• Complies with differentiated services (DiffServ; RFC 2475) Layer 3 Quality of Service (QoS)
implementations.
Notes: If connecting an ESI desktop IP phone to a Power over Ethernet source, the PoE cable must be connected
to the jack labeled NETWORK on the base of the phone. The jack labeled PC does NOT support or provide
Power over Ethernet.
ESI has tested each ESI desktop IP phone with several Power over Ethernet sources. For a current list of
tested devices, see www.esi-estech.com/Resellers/PoE.
®
Important: None of the IP phones listed in this section will work with ESI’s legacy IP E-Class or IVX systems. Similarly,
previous IP Feature Phone models (including the Remote IP Feature Phone) don’t work with ESI
Communications Servers but, instead, are intended for use with only IP E-Class and appropriate, IP-enabled
IVX systems.
ESI Cordless Handsets
ESI Communications Servers also support ESI’s digital, Local IP, and Remote IP Cordless Handsets — both
the Cordless Handset II and the original ESI Cordless Handset models.
Cordless Handset II
The ESI Cordless Handset II includes seven familiar fixed feature keys, eight programmable feature keys, a
speakerphone, and a headset jack. The Base Station for the ESI Digital Cordless Handset II uses a standard
line cord and is line-powered; and the Base Station for each ESI IP Cordless Handset II (Local IP or Remote
IP) uses Ethernet cabling, and receives (and requires) Power over Ethernet (PoE). The ESI Remote IP
Cordless Handset II base station also includes a jack into which the user can plug an analog CO line. This
gives the home-based teleworker the convenience of using both home and business lines with the ESI
Remote IP Cordless Handset II. Each ESI Cordless Handset II model employs advanced DECT 6.0
technology which, as compared to the original ESI Cordless Handsets, allows more secure communications
and — through the use of one or more optional ESI Cordless Handset II Repeaters — greater range.
Original Cordless Handsets
The original ESI Cordless Handsets come in two sizes — small and large — and each includes four familiar
fixed feature keys, four programmable feature keys, and a headset jack. The Base Station for each ESI digital
Cordless Handset uses a standard line cord and is line-powered; and the Base Station for each ESI IP
Cordless Handset uses Ethernet cabling and receives (and requires) Power over Ethernet (PoE). The ESI
Remote IP Cordless Handset base station also includes a jack into which the user can plug an analog CO
line. This gives the home-based teleworker the convenience of using both home and business lines with the
ESI Remote IP Cordless Handset.
1
Important: Each ESI IP phone draws up to 7.25 watts at 48 volts DC; therefore, each advertises itself to a Power over
Ethernet switch as a Class 3 device per the 802.3af standard. Most PoE switches adhering to this standard will
provide up to 12.5 watts for each Class 3 device.
1
An ESI desktop IP phone’s power consumption takes into account an optional 60-Key Expansion Console.
B.3
ESI Communications Servers Hardware Installation Manual
Phones
Expansion Consoles
The 60-Key Expansion Console gives a designated user 60 additional programmable feature keys. It is
supported by the ESI 60 (digital or IP models), ESI 40 (digital or IP models), and 48-Key Feature Phone (digital
or IP models). The Expansion Console is connected to its host ESI phone via a special cable (provided) and
doesn’t require a separate station port of its own. Additionally, it may be connected to a 60-Key Second
Expansion Console via a special cable (provided with the 60-Key Second Expansion Console) so that one
phone can have a total of 120 programmable feature keys in addition to its own complement of such keys.
Each ESI Communications Server has a maximum number of stations that can have one or two Expansion
Consoles (60-Key and 60-Key Second) installed in a fully configured system:
ESI-1000
128
Maximum Expansion Consoles
ESI-600
ESI-200
ESI-100
80
32
8
ESI-50
8
Note: Regardless of ESI Communications Server model, a Base Cabinet can support a maximum of eight
Expansion Consoles, and each Expansion Cabinet can support a maximum of 24 Expansion Consoles.
Phone overlays
Each ESI phone comes with one overlay for the programmable feature keys. To order additional overlays, visit
™
the DESI Web site, www.desi.com. While there, you may also want to download the free Windows-based
software, DESI Lite, which allows you to print on the overlays. For assistance with DESI products, contact DESI
(the DESI Web site contains contact information).
Tip: Remember that ESI System Programmer software, available from www.esi-estech.com/Resellers, also
lets you print on the overlays as well as perform many other programming tasks.
VIP Softphone
VIP Softphone integrates the features of VIP Professional and an ESI desktop IP phone into a PC-based,
full-audio phone. With the appropriate license, VIP Softphone can be configured for use locally or remotely.
This product requires a third-party USB headset.
Note: For details, see the VIP Product Overview (ESI document #0450-0608) and the VIP Setup and User’s Guide
(ESI document # 0450-0513).
B.4
ESI Communications Servers Hardware Installation Manual
Licensing
Licensing
There are various types of licenses needed to activate certain features and functionality. The following ESI
Communications Server-supported features, products, and capabilities require license activation:
•
•
VIP.
•
VIP Professional.
An ESI remote IP station.
•
•
VIP PC Attendant Console.
VIP ACD Supervisor.
An ESI local IP Cordless Handset.
•
VIP ACD Agent.
An ESI remote IP Cordless Handset.
•
•
ESI Mobile Messaging.
ESI Media Management — Two license types:
Any of the following, the operation of each of which
requires a UIP (universal IP) license:
–
–
–
–
–
–
–
An ESI local IP station.
An Esi-Link channel.
– Audio recordings.
– Video recordings.
A SIP trunk.
VIP Softphone (requires purchase of the VIP
Softphone application)
•
•
ESI Video Viewer.
A third-party SIP station.
Note: Each reference to a VIP software application, above, applies to both the standalone (SE) and Outlookintegrated versions of the application.
License activation
To have licenses activated by ESI Technical Support:
1. Licenses must already have been ordered from ESI.
2. The ESI Communications Server must have either:
•
•
A CO line connected to it (analog, PRI, or T1);
or
1
The NSP, which is connected to a LAN with a public IP address, “port-forwarded” to it.
3. You’ll need the following to provide to the ESI representative:
•
The ESI sales order number.
•
•
The customer (site) name.
The phone number of the CO line or the public IP address of the NSP.
•
The quantity of VIP Professional and VIP ACD Agent licenses.
2
IP Phone licenses
3
Before an IVC will connect to an IP phone , the phone will require an available IVC port and the activation within the
system of a UIP license. When an IP phone is programmed in the system (Function 31), this consumes a license.
A new compatible ESI IP Phone, when connected to a LAN with an ESI Communications Server connected to it,
can be configured in setup mode. However, if a new extension number is assigned to the phone and there are
no local IP Phone licenses available, the phone will display LICENSE EXCEEDED (but play no prompt).
Important: The ESI-50 also requires purchase of IP/Esi-Link feature activation. For more information about this fee,
contact your ESI sales representative at 800 374-0422.
1
2
3
For more information about the NSP, refer to NSP Installation Made Simple (ESI #0450-0669).
VIP ACD Agent uses the same license part numbers as VIP Professional, allowing mixing and matching as the customer may require; e.g., 100 such
licenses could be used for 60 VIP Professional installations and 40 VIP ACD Agent installations. For licensing information for VIP PC Attendant Console
and VIP ACD Supervisor, refer to their respective Product Overviews (ESI document #0450-0914 for VIP PC Attendant Console and #0450-0988 for
VIP ACD). VIP Softphone is sold as a single license (part #5000-0434), which provides one user with VIP Professional features and Softphonespecific capabilities. The VIP Softphone license is selected at the time of purchase for local or remote operation.
An ESI 60 (IP model), ESI 40 (IP model), 48-Key IP Feature Phone II, IP Cordless Handset (Local or Remote), VIP Softphone, or SIP phone.
C.1
ESI Communications Servers Hardware Installation Manual
System capacities
System capacities
Important: Each ESI Presence Management RFID Reader (digital model) uses one digital station. The same is true for
each ESI Cellular Management Access Device.
Stations and trunks
The specifications shown below reflect maximum capacities and configurations. Not all of the station and trunk
maximums can be reached simultaneously.
Example: The ESI-100 can’t achieve 72 IP stations and 48 digital stations and 28 analog stations and 42 trunks
and 24 Esi-Link stations at the same time, because the system’s four-port-card limit makes such a
configuration impossible. The maximum configuration for this system is 108 ports, which could be achieved
by one DLC12 card (24 T1 trunks, 12 digital stations), two IVC 24Rs (48 IP stations), and one IVC EL24
(24 Esi-Link channels).
Dialing plans (-digits)
Max. port cards
2
Max. port configuration
– Max. stations
– Max. IP stations
– Max. digital stations
– Max. analog stations
Max. CO lines
Max. DLCs (T1/PRI)
Max. IVCs
Max. Esi-Link port cards (up to 24
5
Esi-Link channels per card)
Max. SIP trunk cards
Max. SIP trunks
ESI-1000
Four
Three
42
14
1,128
276
816
168
816
168
504
168
384
56
240
84
10
3
34
7
ESI-600
Four
Three
28
14
624
276
408
168
408
168
336
168
188
56
168
84
6
3
17
7
ESI-200
Four
Three
14
14
300
276
192
168
192
168
168
168
56
56
84
84
3
3
8
7
ESI-100
Four
Three
5
5
108
108
84
84
72
72
48
48
28
28
42
42
1
1
3
3
ESI-50
Four
Three
1
1
4
4
87
87
52
52
12
12
32
32
8
8
35
35
3
3
1
1
4
4
1
1
4
4
2
2
1
1
1
1
1
1
10
240
3
72
6
144
3
72
3
72
3
72
1
24
1
24
1
24
1
24
Dedicated ports
Dialing plans (-digits)
Voice mail/auto attendant ports
Conference ports (max. of 16
members per conference)
6
NSP
7
Overhead paging ports
Serial/SMDR ports
ESI-1000
Four
Three
ESI-600
Four
Three
ESI-200
Four
Three
8, 16,
8, 16,
or 24
or 24
128
128
32
32
64
64
64
64
24
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
ESI-100
Four
Three
ESI-50
Four
Three
4 or 8
4 or 8
2, 4, or 6 2, 4, or 6
24
16
16
16
16
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Voice mail capacities
Dialing plans (-digits)
Voice mail storage (hours)
Broadcast mailbox (one to
all extensions)
Cascade notification mailboxes
Group mailboxes/max. members
Guest/info mailboxes
Maximum station mailboxes
Q & A mailboxes
1
2
3
4
5
6
7
ESI-1000
Four
Three
ESI-600
Four
Three
ESI-200
Four
Three
70, 140, 70, 140,
or 600
or 600
ESI-100
Four
Three
70 or
70 or
140
140
1,200
1,200
1,200
1,200
Yes
Yes
Yes
Yes
Yes
Yes
Yes
40
64/200
1,000
816
20
10
32/200
190
168
10
20
32/64
1,000
408
20
10
32/64
190
168
10
10
16/64
1,000
192
10
10
16/64
190
168
10
10
16/32
1,000
84
10
Includes built-in 482 port card.
Includes Esi-Link channels.
ESI-50 supports only PRI.
IVC 12 is built into the ESI-50 main board;supports up to 12 local IP or up to eight remote IP channels.
Esi-Link channels are allocated to “reserved” ports; i.e. Esi-Link channels do not reduce CO or station capacity.
Network Services Processor.
On the ESI-200: A non-IVC card must be installed in slot 1 or 2. On the ESI-100: An IVC can’t be installed in slot 1.
D.1
ESI-50
Four
Three
15 or 30
15 or 30
Yes
Yes
Yes
10
16/32
190
84
10
10
16/32
1,000
52
10
10
16/32
190
52
10
ESI Communications Servers Hardware Installation Manual
System capacities
Departments
Dialing plans (-digits)
Max. departments
Department types: Ring-all, ACD,
UCD, in-order, pick-up, attendant
Max. members, non-ring-all depts.
Max members, ring-all depts.
ESI-1000
Four
Three
ESI-600
Four
Three
ESI-200
Four
Three
ESI-100
Four
Three
ESI-50
Four
Three
128
20
64
20
20
20
10
10
10
10
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
64
48
64
48
64
48
64
48
48
48
48
48
32
32
32
32
32
32
32
32
Shared-office tenanting
Dialing plans (-digits)
Tenants
ESI-1000
Four
Three
8
8
ESI-600
Four
Three
8
8
ESI-200
Four
Three
4
4
ESI-100
Four
Three
2
2
ESI-50
Four
Three
2
2
ESI-1000
Four
Three
Yes
Yes
ESI-600
Four
Three
Yes
Yes
ESI-200
Four
Three
Yes
Yes
ESI-100
Four
Three
Yes
Yes
ESI-50
Four
Three
Yes
Yes
CO line groups
Dialing plans (-digits)
Line groups 9, 8, 71–76
Max. members, CO ring
assignment list
48
48
48
48
48
48
32
32
32
32
Translation tables
Dialing plans (-digits)
1
Pilot numbers (non-SIP )
2
Pilot numbers (using SIP )
Max. DID entries
ESI-1000
Four
Three
80
80
100
100
1,200
1,200
ESI-600
Four
Three
40
40
100
100
600
600
ESI-200
Four
Three
20
20
100
100
300
300
ESI-100
Four
Three
10
10
100
100
300
300
ESI-50
Four
Three
10
10
100
100
300
300
ESI-600
Four
Three
1,000
100
ESI-200
Four
Three
1,000
100
ESI-100
Four
Three
1,000
100
ESI-50
Four
Three
100
100
ESI-100
Four
Three
ESI-50
Four
Three
System speed-dial numbers
Dialing plans (-digits)
System speed-dial numbers
ESI-1000
Four
Three
1,000
100
Maximum installations of VIP applications3
Dialing plans (-digits)
Installations,
VIP PC Attendant Console
Installations,
VIP auto-recording
Installations,
VIP ACD Supervisor
1
2
3
ESI-1000
Four
Three
ESI-600
Four
Three
ESI-200
Four
Three
16
16
8
8
4
4
2
2
2
2
32
32
16
16
8
8
4
4
4
4
16
16
8
8
4
4
2
2
2
2
Prior to June 15, 2009.
With release of system software on or after June 15, 2009.
Standalone (SE) or Outlook-integrated versions.
D.2
ESI Communications Servers Hardware Installation Manual
System capacities
ESI Presence Management features
Dialing plans (-digits)
RFID Reader access door records
1
RFID Reader entries in Fn. 372
Max. RFID tags (“electronic keys”)
ESI-1000
Four
Three
50,000
50,000
64
64
2,000
2,000
ESI-600
Four
Three
10,000
10,000
32
32
500
500
ESI-200
Four
Three
10,000
10,000
32
32
500
500
ESI-100
Four
Three
10,000
10,000
16
16
500
500
ESI-50
Four
Three
10,000
10,000
16
16
500
500
ESI-200
Four
Three
Yes
Yes
ESI-100
Four
Three
Yes
Yes
ESI-50
Four
Three
Yes
Yes
ESI-200
Four
Three
168
168
100
100
ESI-100
Four
Three
84
84
50
50
ESI-50
Four
Three
52
52
50
50
ESI-100
Four
Three
14
12
ESI-50
Four
Three
12
12
ESI Cellular Management features
Dialing plans (-digits)
Support for ESI Cellular Mgmt.
ESI-1000
Four
Three
Yes
Yes
ESI-600
Four
Three
Yes
Yes
ESI Mobile Messaging features
Dialing plans (-digits)
Maximum stations
Maximum guest mailboxes
ESI-1000
Four
Three
816
816
250
250
ESI-600
Four
Three
408
408
250
250
ESI Video Viewer and ESI Video Adapters
Dialing plans (-digits)
ESI Video Adapters
RFID Readers per
ESI Video Adapter
User exts./depts. per
ESI Video Adapter
ESI Video Viewer users,
Advanced
ESI Video Viewer users, Basic
ESI-1000
Four
Three
32
32
ESI-600
Four
Three
24
24
ESI-200
Four
Three
16
16
1
1
1
1
1
1
1
1
1
1
64
64
64
64
48
48
32
32
32
32
30
30
20
20
15
15
10
10
5
5
Unlimited
ESI Media Management features
Dialing plans (-digits)
Video recordings
Audio recordings
SMDR events
Fob activity
ESI Media Manager users
ASCs per system
ESI-1000
Four
Three
48
48
384
384
Yes
Yes
Yes
Yes
30
30
20
20
ESI-600
Four
Three
36
36
192
192
Yes
Yes
Yes
Yes
20
20
14
14
ESI-200
Four
Three
24
24
64
64
Yes
Yes
Yes
Yes
15
15
7
7
ESI-100
Four
Three
12
12
32
32
Yes
Yes
Yes
Yes
10
10
1
1
ESI-50
Four
Three
12
12
32
32
Yes
Yes
Yes
Yes
5
5
1
1
Note: For SMDR events or fob activity, maximum stored events per each system is 20,000.
1
See the ESI Communications Servers Programming Manual (ESI document #0450-1050) or the ESI Presence Management Installation Manual
(ESI document #0450-0792).
D.3
ESI Communications Servers Hardware Installation Manual
Cautions and regulatory information
Cautions and regulatory information
Cautions
Important: This information complies with the requirements of Underwriters’ Laboratories (UL) and UL Standards 1950,
60950, and 60950-1, as applicable.
When using this telephone equipment, always exercise basic safety precautions in order to minimize the risk of fire,
electric shock or injury to persons. Before proceeding, please read the following:
•
Do not use liquids or aerosols to clean any system equipment; rather, use a cloth that is only slightly damp.
•
An ESI Communications Server contains no components that are serviceable by either non-Resellers or
non-manufacturer technicians. All service must be referred to the Reseller for further handling.
•
•
Do not install the cabinet in areas with extreme heat or improper ventilation.
Install the cabinet only in “low-traffic” or “non-public” areas.
•
To reduce the risk of fire, use only 24 AWG or larger telecom wire.
Power supply
Heed all warnings and instructions in documentation or marked on the cabinet or peripheral equipment.
Fuse
Contact the factory before attempting to replace the fuse. The fuse is located on the main board in the Base
Cabinet, and (for the ESI-1000, ESI-600, and ESI-200) on the backplane in the Expansion Cabinet.
Battery (located on the main board)
“Caution: There is a danger of explosion if the onboard lithium battery is incorrectly replaced. Replace only with Ray-O-Vac
BR1225 (or equivalent). Dispose of used batteries according to the battery manufacturer’s instructions.”
“Notice: This product is intended to be supplied by a Listed Direct Plug-In Power Unit marked ‘Class 2’ and provided
with electrical ratings.”
E.1
ESI Communications Servers Hardware Installation Manual
Cautions and regulatory information
Regulatory information
United States of America
Registration
The CO line telephone numbers, FCC registration number, and ringer equivalence number (REN) of this
equipment must be provided to the telephone company before installation. (See below for FCC registration
number and ringer equivalence number.)
FCC Part 15
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses
and can radiate radio frequency energy and — if not installed and used in accordance with the instruction
manual — may cause harmful interference to radio communications (in which case, the user will be required
to correct the interference at his/her own expense).
FCC Part 68
This equipment complies with Part 68 of the FCC Rules. On the bottom of this equipment is a label that
contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for
this equipment. You must, upon request, provide this information to your telephone company.
The REN is helpful to determine the quantity of devices you say connect to your telephone line and still have
all of those devices ring when your telephone number is called. In most, but not all, areas, the sum of the
RENs of all devices connected to one line should not exceed five (5.0). To be certain of the number of
devices you may connect to your line, as determined by the REN, you should contact your local telephone
company to determine the maximum REN for your calling area.
If your telephone equipment causes harm to the telephone network, the telephone company may discontinue
your service temporarily. If possible, the telephone company will notify you in advance but, if advance notice
is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint
with the FCC.
Your telephone company may make changes to its facilities, equipment, operations or procedures that could
affect the proper functioning of your equipment. If so, you will be notified in advance, to give you an
opportunity to maintain uninterrupted telephone service.
If you experience trouble with this telephone equipment, the telephone company may ask that you disconnect
this equipment from the network until the problem has been corrected or until you are sure that the equipment
is not malfunctioning.
This equipment may not be used on coin service provided by the telephone company. Connection to party
lines is subject to state tariffs.
Installation: The device is equipped with a USOC connector.
Registration Number: 1T1MF08B33727.
Ringer equivalence number (REN): 0.8
Hearing-aid compatibility
This equipment, utilizing telephone station equipment manufactured by ESI, meets all FCC requirements for
hearing-aid compatibility.
E.2
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Hardware installation: ESI-1000, ESI-600, ESI-200
Site location
As with most electronic equipment, the environmental considerations for this site need to observe good common
sense. Provide a dry, clean, and accessible area.
Locate space in the telephone equipment room, which will provide easy connection to the termination blocks and
110 VAC power. The location should be no further than 1,000 feet from the farthest station.
0
0
Ambient room temperature must be 40 –80 (F.), and relative humidity no higher than 90%.
Notes: Do not place the equipment or run station cabling near high voltage electrical equipment or electrical lines
susceptible to high voltage surges from air conditioner compressors, etc.
Do not mount the equipment in a place that receives direct sunlight.
Mounting the cabinet(s)
If wall-mounted, the system and supporting components should be mounted to a half-inch (or thicker)
plywood backboard. To wall-mount a Base Cabinet or Expansion Cabinet, use the five tabs located at the rear of
the cabinet. The center tab has an enlarged hole and slot, to allow you to fix the screw on the wall before
hanging the cabinet onto the screw. Once you’ve done so, fasten the other screws into the four remaining holes
to finish securing the cabinet onto the wall.
To rack-mount a Base Cabinet or Expansion Cabinet, use the forward-facing screw holes on the sides of the
cabinet. Only two screws are needed per side (in fact, on most server racks, you can’t use all four screws on
each side).
Allow room for installation of the Expansion Cabinet either now or in the future; the Expansion Cabinet must be
installed directly below the Base Cabinet. Allow about two inches of clearance between the units, for cabling.
Attach the power transformer to the wall or rack, allowing sufficient length in both cords to reach the power
connector on the front side of the cabinet and to reach a UPS or a dedicated 110 VAC outlet.
ESI-1000, ESI-600, or ESI-200 typical installation
F.1
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Expansion Cabinet installation
To expand the system, you must add the Expansion Cabinet.
1. Use the expansion cable (supplied with the Expansion Cabinet) to connect the Input jack of the Expansion
Cabinet to the Expansion jack of the Base Cabinet.
2. ESI-1000 and ESI-600 only: Add additional Expansion Cabinets by using the expansion cable to connect
the Input jack of the next Expansion Cabinet to the Expansion jack of the previous cabinet.
3. Connect the ground of all units to the system ground. (See also “Grounding instructions,” page I.1)
4. Connect both power supplies to the standard power strip and then connect to the UPS.
Important: Always apply power to all cabinets simultaneously by using the power strip’s switch.
Do not apply power until all hardware connections have been made.
Port card installation
“CS” port cards
“CS” port cards should be inserted from left to right, without skipping any slots. (If there are any empty slots
between port cards, any cards to the right of the empty slot won’t be operational.)
1
Important: Although all “CS” cards are hot-swappable , ALWAYS power down the entire system (ALL cabinets)
BEFORE adding a new port card or permanently removing an existing port card. Also, be sure to
observe all proper procedures regarding the prevention of electrostatic discharge (ESD) when
performing the following procedures; otherwise, circuit boards may suffer damage.
1. On the desired slot in the cabinet, press the
release buttons on the top and bottom to
release the blank faceplate (Fig. 1).
2. Slide the port card into the card guides at the
top and bottom of the cabinet. Then, gently
push the port card into the cabinet (Fig. 2).
Fig. 1
3. When you feel some resistance, apply a
little more pressure until you feel the
port card’s edge connectors “click” into the
connector on the backplane. At this point,
the port card’s faceplate should be in contact
with the front of the cabinet.
4. Press the port card’s ejector handles into
the locking position (Fig. 2), so that they click
into place behind the release buttons.
Fig. 2
5. If you have no more cards to install at this time, power-up and program the system.
1
If using an “E2” port card in the ESI-200, ESI-600, or ESI-1000, you must also use a Hot-Swap Adapter (ESI part #5000-0462) for hot-swap operations.
F.2
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
“E2” port cards
1
Each “E2” port card must be mounted onto a “Hot Swap” Port Card Adapter (ESI part # 5000-0462) prior
to being installed on the ESI Communication Server. Using “Hot Swap” Port Card Adapters allows you to
“hot-swap” port cards — i.e., replace them while the system is powered-up. However, installing a new port
card requires power-cycling the system to allow it to recognize the new card.
Important: While they are physically similar to the Port Card Adapters for the IVX X-Class system, “Hot-Swap” Port
Card Adapters are for use with only ESI Communications Servers. Similarly, you should use only “HotSwap” Port Card Adapters on ESI Communications Servers.
Wear a grounding strap and avoid unnecessary movement while handling the circuit boards and
Port Card Adapters.
To install the port card on the Port Card Adapter:
1. Place the port card’s Amphenol connector through the
opening of the Port Card Adapter’s faceplate, while
simultaneously aligning the port card’s screw holes
with the Port Card Adapter’s standoffs.
2. Screw the port card to the Port Card Adapter,
using the five provided Phillips-head machine screws.
3. Plug one end of the gray flat ribbon cable into the
Port Card Adapter connector.
4. Fold the gray flat cable as shown, and plug its other end
into the port card connector.
5. Install the assembled port card/Port Card Adapter into
the Base Cabinet, following the instructions under
“CS port cards,” page F.2.
1
If you’re installing an “E2” port card on an ESI-600 with a metal faceplate, you’ll need the “Hot Swap” Port Card Adapter with a metal faceplate
(ESI part # 5000-0385).
F.3
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
About replacing port cards
Important: The main board, expansion board, and expansion cable cannot be removed or replaced under power. The
entire system must be powered-down when you install, remove, or replace any of these components.
Notes regarding hot-swapping:
When you replace a port card with a new one, the system will detect the port card type.
If the new port card’s type is different than that of the original port card, the newly installed port card won’t
come on-line.
If the new port card’s type is the same as that of the original port card, the system will automatically upload
software to the new port card. This upload process can take from four minutes to one hour, depending on
the type of port card and how busy the system is at the time.
Hot-swap is not supported during system boot.
If you’re hot-swapping identical cards between two slots, the upload process can take more than twice as
long as when you hot-swap one card at a time.
A port card that’s removed and inserted can’t be removed and inserted again within five minutes.
When replacing port cards, you must observe the following rules and limitations:
1. The replacement port card must be identical to the port card being removed (i.e.: an E2-612 must be
replaced with an E2-612; an ESI-DLC must be replaced with an ESI-DLC; etc.) — with the following
exception: because each “E2” card is functionally identical to its corresponding “CS” version, you could
(for example) remove an E2-684 and replace with a CS-684.
2. BEFORE you remove the port card:
•
The port card must be completely idle.
•
You must remove the cable from the front of the card (25-pair amphenol or Ethernet cable).
3. When removing the port card, follow the instructions under “Port card installation,” beginning on page F.2.
4. Before inserting a replacement port card into a slot, wait at least 15 seconds after removing the previous
port card.
5. When inserting a port card, don’t re-connect the cable to the front connector until the inserted card is on-line.
F.4
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Memory Module installation or replacement
Important: Always power-down the system (all cabinets) before adding or replacing the Memory Module.
Also, be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD)
when performing the following procedures; otherwise, circuit boards may suffer damage.
First, remove the main board from the system . . .
1. In the Base Cabinet, disconnect all cables (such as power, MOH, and
LAN cables) from the front panel of the main board faceplate.
2. Press the release buttons (Fig. MM-1) on the top and bottom of the faceplate
to release the ejector handles.
3. Pull on the ejector handles (Fig. MM-1) to pull the main board from the cabinet.
Fig. MM-1
Next, install the Memory Module . . .
Note: The Memory Module installation procedure varies, depending on whether the Memory Module is a
®
hard drive or a CompactFlash . (An ESI-1000 or ESI-600 Memory Module is always a hard drive.)
Procedure for two hard-drive Memory Modules (ESI-1000)
Note: The installation of these drives enables M3 operation on the ESI-1000; no other hardware is required,
due to the ESI-1000’s built-in M3 interface. (See “Mirrored Memory Module (M3),” page F.9.)
1. Place the mirrored (secondary) hard drive on the work surface
with the printed circuit board up and the connector facing you
(Fig. MM-2). Place a nylon spacer (washer) over each of the
threaded mounting holes.
2. Place the right side of the drive mounting plate over the
hard drive, aligning the holes in the plate with the threaded
holes on the hard drive.
(Continued)
Fig. MM-2
F.5
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
3. Screw two of the standoffs through the drive mounting plate
into the top-right and bottom-right threaded holes with the
spacers. Screw two of the screws that came with the hard drive
into the remaining holes (Fig. MM-3).
4. Using the primary hard drive, repeat steps 1–2.
Fig. MM-3
5. Screw the remaining standoffs through the
drive mounting plate into the top-left and
bottom-left threaded holes with the spacers.
When you’re done, the hard drive subassembly
should look like Fig. MM-4.
6. Use the remaining screws to attach the
assembly to the main board through the
main board’s four holes to the standoffs.
Be sure to align the hard drive pins so that
they’re next to the hard drive connectors on
the main board.
Fig. MM-4
7. Connect the two hard drive cables — the primary drive should be connected to J6 and the
secondary drive should be connected to J7. Be sure to tuck the excess ribbon cable between the
main board and hard drives. The full assembly should look like Fig. MM-5.
Fig. MM-5
F.6
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Procedure for a hard-drive Memory Module (ESI-600 • ESI-200)
1. Install onto the new Memory Module the standoffs provided with it.
Important: Be careful not to over-tighten the standoffs.
2. Position the Memory Module over the four screwholes and
install the four screws provided with the Memory Module.
Important: Be careful not to over-tighten the screws
into the Memory Module standoffs.
3. Connect the cable provided with the Memory Module to either
J5 (ESI-200) or J6 (ESI-600) on the main board (Fig. MM-6).
Verify that the cable is fully seated at both ends.
Fold excess cable back over the top of the
Memory Module.
Fig. MM-6
Procedure for a CompactFlash Memory Module (ESI-200 only)
1. Attach the two standoffs to the main board by using
two of the four provided screws. Locate the two holes
closest to J5 on the main board (Fig. MM-7); then,
place the two screws through the holes from the bottom
and loosely attach the standoffs to the screws.
2. Use the two remaining screws to install the
CompactFlash adapter onto the two standoffs.
Important: Be careful not to over-tighten the standoffs.
3. Connect the cable provided with the CompactFlash
Memory Module to J5 on the main board (Fig. MM-7).
Verify that the cable is fully seated at both ends.
Fold excess cable back into the open space between
the main board and the CompactFlash adapter.
Fig. MM-7
4. Slide the CompactFlash Memory Module into the adapter.
Finally, reinstall the main board in the system . . .
1. Slide the main board into the card guides at the top and bottom of the cabinet, and push the main
board gently into the cabinet.
2. When you feel some resistance, apply a little more pressure until you feel the main board “click”
into the connector on the backplane. At this point, the faceplate should be in contact with the front of
the cabinet.
3. Push the ejector handles into their locking position, so that they click into place behind the release buttons.
4. Reconnect to the faceplate’s front panel the cables you removed in step 1 under “First, remove the
main board from the system . . .” (page F.5).
5. Power-up the system.
Important: Remember that, if you have multiple cabinets in the system, you must power-up all of them at
the same time.
F.7
ESI Communications Servers Hardware Installation Manual
Removing the Memory Module from
the main board
ESI-1000, ESI-600, ESI-200
Fig. MM-8
1. Follow steps 1–3 under “First, remove the
main board from the system . . .” (page F.5).
2. Remove the Memory Module cable connected to either J5
(ESI-200) or J6 (ESI-1000/ESI-600) at the rear of the
main board (Figs. MM-6 and MM-7, page F.7).
Note: On the ESI-1000, be sure also to remove the cable
for the secondary Memory Module from J7.
3. From the back of the main board (Fig. MM-8), remove the four
Philips screws securing the Memory Module standoffs.
Remove the Memory Module with the standoffs attached.
4. Remove the four standoffs from the Memory Module.
5. Follow the steps under “Next, install the Memory Module . . .”
(page F.5) and “Finally, reinstall the main board in the system . . .” (this page) to (a.) install a replacement
Memory Module onto the main board and then (b.) reinstall the main board in (and power-up) the system.
F.8
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Mirrored Memory Module
Note: For full instructions on installing the M3, see its Installation Guide (ESI #0450-0912).
The Mirrored Memory Module (M3) ensures reliability and survivability of compatible ESI Communications Servers.
1
Using RAID -1 hard-disk drive technology, mirrored hard drives are intended to maintain system operation on
one disk drive in the event a hard drive fails. No system programming is required for the M3 to function.
Note: The ESI-1000 has all M3 components built-in, so the installation on the ESI-1000 of the hard-drive Memory
Modules (see “Procedure for two hard-drive Memory Modules (ESI-1000),” page F.5) enables M3 operation
on that system. M3 components are optional for the ESI-600 and ESI-200, and must be installed onto the
ESI Communications Server main board.
The M3 is a printed circuit assembly that supports two identically configured hard drives, mounted on standoffs.
It also has LED indicators, an audible alarm, alarm reset button, and an IDE cable connector for connection to
the main board.
For the mirroring operation to function properly on the ESI Communications Server, each hard drive must be
formatted and prepared by ESI.
Installing the M3 (ESI-600 • ESI-200)
The M3 kit consists of an M3 printed circuit board, hard drive mounting plate, faceplate, four (4) 1-inch
standoffs, 12 nylon spacers (washers), eight (8) screws, and an IDE cable for connection to the main board.
Refer to Fig. M3-1, below, to identify and locate where these components will be installed.
Memory Modules (hard drives, or HDDs) are obtained separately. Note that each hard drive must be an
ESI-formatted drive for the mirroring operation to function properly.
The M3 board itself includes LED indicators, cable connectors, an audible alarm, and alarm reset button.
Fig. M3-1: Mounting locations of M3 hardware
Important: If the M3 is being installed on a system that already has an existing Memory Module (hard disk drive),
the existing Memory Module must be installed in the M3 as the primary HDD (see Fig. M3-3). If it is
not, then the drive synchronization will not operate correctly, and the system will have to be initialized
and reprogrammed.
Fig. M3-2: M3 faceplate
1
Fig. M3-3: Hard-disk drive positions on M3
Stands for redundant array of independent drives.
F.9
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
What you’ll need
Here’s what you’ll need to install the M3:
•
•
-inch nut driver.
#1 Phillips screwdriver.
•
A well-lit, clean and static-free work area.
1
. . . along with these specific additional items:
ESI Communications
Server
ESI-600
ESI-200
Additional items required for
installing the M3
• ESI-600 main board
•
A second ESI-600
Memory Module
•
ESI-200 main board
•
A second ESI-200
Memory Module
Fig. M3-4:
Main board template
(ESI-600 shown)
Important: To successfully install the M3, you must follow, in the correct order, the
steps listed beginning below. If the main board is already installed in
the system, you’ll need to power down the system and remove the
main board as explained in “Memory Module installation or
replacement” (beginning on page F.5).
M3 installation: Prepare the main board
1. If there is a hard drive already mounted on the main board, follow the instructions in the Memory
Module installation instructions (beginning on page F.5). Set aside the four screws and three of
the -inch standoffs; you’ll be using them later to secure the hard drive to the M3 mounting plate.
2. Unscrew the two screws holding the cover over the rectangular opening on the main board
faceplate. Set aside the two screws; you’ll be using them later to secure the M3 faceplate to the
main board faceplate.
3. Unplug the expansion cable from the main board (there is no need to remove the expansion cable
connector from the faceplate).
4. Set aside the main board.
(Continued)
1
ESI strongly recommends that an approved ESD wrist strap be worn when working with electronic equipment.
F.10
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
M3 installation: Prepare the M3 board
There are two sets of mounting holes on the
M3 board. One set is for mounting the M3
on the ESI-200 main board (referenced by
the gray arrows marked “X” in Fig. M3-5);
and the other set aligns with the holes on
the ESI-600 main board (the white arrows
marked “ES” in Fig. M3-5).
1. Locate the four mounting holes on
the M3 board.
2. Using four of the screws and four of the
nylon washers that came with the M3 kit,
install the four 1-inch standoffs onto the
M3 board. The nylon washers should be
placed between the M3 board and the standoffs.
The standoffs should be mounted on the side of
the M3 board without the cable connectors.
Refer to Fig. M3-5.
Fig. M3-5: Mount standoffs to M3 board
3. Set aside the M3 board.
M3 installation: Assemble the hard drives to the
mounting plate
For this assembly, you’ll be using six of the -inch standoffs, and one
of the screws, included with the hard drives.
1. Place the mirrored (secondary) hard drive on the work surface
with the printed circuit board up and the connector facing you (as
shown in Fig. M3-6, right). Place a nylon spacer (washer) over
each of the threaded mounting holes.
2. Place the right side of drive mounting plate over the hard drive,
aligning the holes in the plate with the threaded holes on the
hard drive (see Fig. M3-7, below).
3. Screw three of the -inch standoffs through the drive mounting
plate into the top-left, top-right, and bottom-right threaded holes
with the spacers. Screw one of the screws that came with the
hard drive into the remaining hole (see Fig. M3-7, below).
Fig. M3-7: Attach the hard drive mounting plate
(Continued)
F.11
Fig. M3-6: Place nylon spacers
on HDD screw-holes
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
4. Using the primary hard drive, repeat steps 1 and 2 (under “Assemble the hard drives to the
mounting plate,” page F.11).
5. Screw the remaining -inch standoffs through the drive mounting plate into the top-left, top-right,
and bottom-left-threaded holes with the spacers. When done, the hard drive subassembly should
look like Fig. M3-8, below.
Fig. M3-8: Completed hard drive subassembly
M3 assembly: Attach the hard drive subassembly to the M3 board
1. Align the threaded holes at the end of the standoffs of the hard drive subassembly to the six holes
on the M3 board. The connectors on the hard drives should be facing towards the connectors on the
M3 board (see Fig. M3-3, page F.9).
1
2. Using the remaining screws that came with the hard drives, attach the hard drive subassembly to
the M3 board. See Fig. M-9, below, for the locations of the screws. Note that you’ll be using only
six screws.
Fig. M3-9: Mount hard drive subassembly on M3
(Continued)
1
If you’re using a drive that was already installed, use the screws you removed in step 1 of “M3 installation: Prepare the main board” (page F.10).
F.12
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
M3 assembly: Attach the M3 assembly to the main board
1. Align the threaded holes at the end of the four standoffs of the M3 subassembly to the four hard
drive mounting holes on the main board.
2. Using the remaining four screws from the M3 kit, attach the M3 assembly to the main board. Make
sure that the M3 faceplate is aligned with the opening on the main board faceplate. See Fig. M3-10,
below, for the mounting screw locations.
Fig. M3-10: Location of M3 mounting screws (ESI-600 main board shown, without faceplate)
3. Screw the M3 faceplate to the main board faceplate, using the screws you removed in step 2 of “M3
assembly: Prepare the main board” (page F.10).
4. Connect the hard drive cables from each drive to the respective connectors on the M3 board (J5
and J6). To prevent the hard drive cables from interfering with inserting the main board, fold the
cables in toward the hard drives (see Fig. M3-11, below).
5. Connect the M3 (connector J4) to the main board hard drive connector (J6) by using the IDE cable
that came with the M3 kit.
6. Plug back in the expansion cable you removed in step 2 of “M3 assembly: Prepare the main board”
(page F.10).
7. Confirm that the installation matches the picture in Fig. M3-11, below.
If it does, you’re done, and you can install the main board back into the system.
Fig. M3-11: Completed M3 installation (ESI-600 main board and faceplate shown)
Note: The photo in Fig. M3-11 is intended only as a representation. Your M3 installation will look somewhat
different, depending on the ESI Communications Server.
F.13
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Mirroring operation
On system power-up — e.g., at initial installation or whenever a drive is replaced — the M3 will first verify that
each drive is an ESI-formatted drive. If so, it then will transfer all data from the primary drive to the mirroring
drive. This process can take anywhere from a few minutes to one hour, depending on system activity, amount
of voice message storage, and configuration. System operation won’t be affected during the data transfer,
because this transfer will occur only when call-processing is making no disk drive access requests.
If a primary drive is replaced, data will be copied in the same fashion from the mirror drive to the new primary
drive. Again, the replacement drive must be a new, unprogrammed ESI drive. If it’s not, the system may
copy all data in the wrong direction — i.e., from the new (mostly empty) primary drive to the mirror drive!
Therefore, ESI recommends that the mirror drive be moved to the primary drive mounting position and the
new drive be mounted on the mirror drive mounting position.
Note: Once a hard drive has been copied, if it is removed and installed on a different system, the system will
automatically initialize the drive, erasing all data and voice messages.
Panel indicators and controls
The M3 panel indicators and Reset/Test button are used primarily for alarm and error
indication and troubleshooting. If the M3 is installed properly and the ESI Communications
Server is powered-on, the M3’s Power LED will always be lit. The following table describes
other M3 indications:
“Primary”
LED
Flicker, steady on,
or off
Fast blink
or steady on
Slow blink
Flicker or off
“Mirror”
LED
Flicker or off
“Error”
LED
Alarm
beep
What it means
Off
Off
Normal operation
Flicker or
steady on
Flicker or off
Slow blink
On
Off
Restoring data to primary or mirror drive
On
On
On
On
Primary drive failure or non-ESI drive installed
Mirror drive failure or non-ESI drive installed
The Reset/Test button is used to mute the audible alarm if a failure or error occurs. Additionally, during
normal operation, you may test the M3 panel indicators by pressing and holding Reset/Test for more than
one second. This will turn on all of the M3’s LEDs and sound the audible alarm until you release the
Reset/Test button.
F.14
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
LED functions
The unit's various LEDs are designed to provide visual feedback as follows:
Power LED
The Power LED is located on the right side of the main board’s faceplace, and is illuminated when power is
being applied to the system. This LED blinks periodically to indicate that the main processor is operational.
Port LEDs
The Port LEDs are located above their respective connectors on each installed port card. Each LED is
illuminated when any port on its associated port card is in use.
Note: Disconnecting a connector when its respective LED is lit will disconnect any of its ports that are in use.
Upon power-up, approximately five minutes are required for the system to configure. The Power and Port
LEDs will blink three times to indicate that the power-up sequence has been completed.
Note: When a DLC’s LED is . . .
• . . . blinking, the T1/PRI circuit is out of service.
• . . . not lit at all, the T1/PRI circuit is in service but is idle.
• . . . lit solidly, the T1/PRI circuit and/or a station on the card are in use.
Memory Transfer LED
This LED is located inside the cabinet under the Memory Module, at the back of the main board. It serves as
a diagnostic aid by flashing as data is transferred to and from the Memory Module.
F.15
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
ESI Presence Management installation
For information on installing ESI Presence Management, see its Installation Manual (ESI # 0450-0792).
ESI Cellular Management installation
Hardware
The ESI Cellular Management Access Device (see graphic, below) is housed in a small, ergonomic plastic case,
which connects to a digital phone port. Although the Access Device is intended for desktop placement near
®
the host ESI phone, it can be attached to any surface by using the included Velcro strips.
The ESI Cellular Management Access Device is powered by the digital port. Each ESI Cellular Management
Access Device requires a single digital port. Only the number of available station ports limits the number of
ESI Cellular Management devices that can be connected to the system.
PAIRING
button
HANDSET LED
PC
jack
NETWORK
jack
DIGITAL
jack
Back panel.
Front panel.
HANDSET LED
A single blue HANDSET LED on the front panel of the ESI Cellular Management Access Device displays
the status of a Bluetooth-enabled cell phone as related to the ESI phone:
•
•
Off — Unpaired with a cellular phone.
Blinking slowly — Not connected (Auto-Connect disabled).
•
•
Blinking moderately — Searching for cell phone (not connected).
Blinking rapidly — In pairing mode.
•
On — Cell phone is paired and connected.
PAIRING button
The PAIRING button, on the rear of the Access Device, is used to initiate the pairing of a Bluetoothenabled handset and/or headset with ESI Cellular Management.
Jacks
The Access Device’s DIGITAL jack is an RJ-11 jack for connecting the Access Device to an ESI digital
port. Power is provided via the included 12-ft. line cord connection to an ESI digital port card.
The PC and NETWORK jacks are reserved for possible future use.
For information on installing ESI Cellular Management, see its Installation Guide (ESI # 0450-1155).
F.16
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Installation of card(s) for ESI Mobile Messaging and SIP trunking
The following instructions cover installation of the CS-SIP24, CS-SIP8, and CS-ASC.
Important: Each card is for ESI Communications Servers only (except ESI-50L) and requires a Hot-Swap Port Card
Adapter (five-pack, ESI # 5000-0462) if used on an ESI-1000, ESI-600, or ESI-200.
Before installing, verify that the system is running the appropriate system software. If it isn’t, download the
correct version from the ESI Resellers’ Web site and install it on the system.
ALWAYS power-down the entire system (all Cabinets) BEFORE adding or replacing any hardware.
Also, be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD)
when performing the following procedures; otherwise, circuit boards may suffer damage.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
Installing the card on the Port Card Adapter
1. Attach the new card to the assembled Port Card Adapter,
using the five screws provided with the new card.
2. Install the port card cable (provided with the new card) into the
shrouded connector on the new card. Fold the cable as
shown (Fig. C-1), and install the other end of the cable into the
shrouded connector on the top edge of the new card.
Figure C-1
Installing the card in the system
Important: Remember to power down the entire system (all cabinets) before either adding or removing port cards.
Note: Although Figs. C-2 and C-4 show only an ESI-600, the
procedure is similar for other applicable ESI
Communications Servers.
1. On the appropriate cabinet, remove the blank plate covering the slot
in which you’ll install the new card/Port Card Adapter, by using the
release buttons at the top and bottom of the plate (Fig. C-2).
2. Slide the card/Port Card Adapter into the card guides (Fig. C-3) at the
top and bottom of the cabinet. Then, gently push the card/Adapter into the cabinet.
Figure C-2
Figure C-3
Figure C-4
3. When you feel some resistance, apply a little more pressure until you feel the Port Card Adapter’s edge
connectors “click” into the connector on the backplane. At this point, the card/Adapter’s faceplate
should be in contact with the front of the cabinet.
4. Secure the card/Adapter to the cabinet by pressing the Port Card Adapter’s ejector handles into the
locking positon (Fig. C-4), so that they click into place behind the release buttons.
5. If you have no more cards to install at this time, power-up and program the system.
F.17
ESI Communications Servers Hardware Installation Manual
ESI-1000, ESI-600, ESI-200
Use of Ethernet connectors
• CS-SIP24 or CS-SIP8 — Both Ethernet® connectors must be connected to the private local area
network (LAN).
• ASC — Only Ethernet Connector #1 must be connected to the private LAN.
For information on programming ESI Mobile Messaging, see its Installation Guide (ESI # 0450-1231).
For information on installing SIP trunking, see the ESI SIP Trunking Installation Guide (ESI # 0450-1227).
Installation of Memory Module for CS-ASC
Important: The CS-ASC (Applications Services Card) is for ESI Communications Servers only (except ESI-50L) and
requires a Hot-Swap Port Card Adapter (five-pack, ESI # 5000-0462) if used on an ESI-1000, ESI-600, or
ESI-200.
Before installing, verify that the system is running the appropriate system software. If it isn’t, download the
correct version from the ESI Resellers’ Web site and install it on the system.
ALWAYS power-down the entire system (all Cabinets) BEFORE adding or replacing any hardware.
Also, be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD)
when performing the following procedures; otherwise, circuit boards may suffer damage.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
®
Installing the ASC Memory Module (hard drive) does not replace the CompactFlash (which is preinstalled).
What you’ll need
Here’s what you’ll need to install the ASC Memory Module (hard drive):
• -inch nut driver
• #1 Phillips screwdriver
• A clean, well-lit, and static-free work area
Procedure
After removing the new card from the box, install the Memory Module
as follows:
Figure H-1
1. Screw into the Memory Module the four -inch standoffs that came with the ASC Memory Module kit.
2. Align:
a. the threaded holes at the end of the hard drive subassembly’s standoffs
. . . to . . .
b. the four holes on the ASC (Fig. H-1).
3. Using the four remaining screws that came with the Memory
Module, attach the Memory Module to the ASC.
4. Connect the Memory Module’s hard drive cable (Fig. H-2) to
the appropriate connector (U12) on the ASC.
Note: To prevent the cable from interfering with insertion
of the main board, fold the cable in toward the
Memory Module as shown in Fig. H-2.
F.18
Figure H-2
ESI Communications Servers Hardware Installation Manual
ESI-100
Hardware installation: ESI-100
Site location
As with most electronic equipment, the environmental considerations for this site need to observe good common
sense. Provide a dry, clean, and accessible area.
Locate space in the telephone equipment room, which will provide easy connection to the 66 blocks and 110 VAC
power. The location should be no further than 1,000 feet from the farthest station.
0
0
Ambient room temperature must be 40 –80 (F.), and relative humidity no higher than 90%.
Notes: Do not place the equipment or run station cabling near high voltage electrical equipment or electrical lines
susceptible to high voltage surges from air conditioner compressors, etc.
Do not mount the equipment in a place that receives direct sunlight.
The system and supporting components should be mounted to a half-inch (or thicker) plywood backboard. Here is
the layout of a typical Base Cabinet installation.
ESI-100 Base Cabinet typical installation
G.1
ESI Communications Servers Hardware Installation Manual
ESI-100
Opening the Base Cabinet
The lid on the Base Cabinet is held in place by two tabs that rest in slots in the bottom
of the case, and a release tab that snaps into an opening in the top-center of the
cabinet and is secured by a retaining screw.
To remove the lid:
1. Remove the retaining screw and depress the release tab at the top of
the cabinet.
2. Rock the lid back from the top.
3. Lift and pull the lid free from the slots in the bottom of the cabinet.
Mounting the Base Cabinet
To mount the ESI-100 Base Cabinet, use the three provided #8 Phillips screws. Note the position of the three
mounting holes in the cabinet. Allow room for installation of the Expansion Cabinet (see page G.3) either now or,
if required, in the future.
1. Screw in the top screw to the backboard (at least half-inch thick
plywood) leaving about one-eighth-inch clearance between the
screw head and the plywood.
2. Hang the unit using the keyhole at the top of the case.
3. Level the unit and install the bottom two screws.
Attach the power transformer to the wall, allowing sufficient length in both cords to
reach the power connector on the upper right side of the cabinet and to reach a UPS
or a dedicated 110 VAC outlet.
G.2
Base Cabinet
ESI Communications Servers Hardware Installation Manual
ESI-100
Expansion Cabinet installation
The Expansion Cabinet allows the ESI-100’s capacity to grow by up to two additional port cards. The cards are
connected via ribbon cables, through the opening in the back of the Expansion Cabinet, to the Base Cabinet.
Note: You can add only one Expansion Cabinet to an ESI-100.
To install an Expansion Cabinet:
1. Wear a grounding strap and avoid unnecessary movement while
handling the circuit boards.
2. Unplug the power to the ESI-100 system.
3. Remove the Base Cabinet lid by pressing the release tab at the top of the
cabinet and rock back the lid from the bottom of the cabinet.
4. Install the Expansion Cabinet on the front of the Base Cabinet in place of
the Base Cabinet's lid.
5. Lock the Expansion Cabinet to the Base Cabinet by snapping the top in
place and reinstalling the retaining screw.
6. Connect the grounding strap from the Expansion Cabinet's grounding lug
(located on the bottom of the cabinet) to the Base Cabinet's grounding
lug. (See also “Grounding instructions,” page I.1).
7. Through the large opening in the back of the Expansion Cabinet,
connect the ribbon cable(s) from the port card(s) to the card
directly below.
8. Re-install the original lid from the Base Cabinet on the face of the
Expansion Cabinet.
Port card installation
Adding or replacing port cards will require the system to be taken out of service
(the ESI-100 doesn’t support “hot-swapping” of its port cards).
Notes: The ESI-100 can use only E2 port cards (see “Port card options,” beginning on page A.4).
ALWAYS power down the system BEFORE adding or replacing any hardware. Also, be sure to
observe all proper procedures regarding the prevention of electrostatic discharge (ESD) when performing the
following procedures; otherwise, circuit boards may suffer damage.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
After removing the E2 port card from the box, install it as follows:
1. Unplug the power supply to the system.
2. Remove the locking screw (at the top of the cabinet, securing
the cover), and then remove the top cover by pressing down
the locking tab and pulling the top cover forward (Fig. PC-1).
Note: Port cards are added to an existing Base Cabinet in a “piggyback”
fashion — i.e., port card 2 (J1) plugs into port card 1 (J2), port card 3
(J1) plugs into port card 2 (J2), etc.
(Continued)
Fig. PC-1
G.3
ESI Communications Servers Hardware Installation Manual
3. A cable is attached to Connector J1 of the E2 port card.
Connect the cable’s other end to Connector J2 of the
cabinet’s existing port card.
ESI-100
Fig. PC-2
4. Secure the E2 port card to the cabinet (Fig. PC-2).
If it’s going into the top slot, use five screws.
If it’s going into the bottom slot, use five standoffs appropriately:
•
7/16-in. standoffs — Between the Base Cabinet and the
first card.
•
3/4-in. standoffs — Between the first and second card
in the Base Cabinet.
•
1-in. standoffs — Between port cards in the
Expansion Cabinet.
Use the screws that ship with the E2 port card to secure
the card to the standoffs. (You may have leftover screws.)
DON’T overtighten the standoffs; it will strip the
plastic bosses.
5. Put the top cover back on the cabinet, and then replace
the locking screw to secure the cover on the cabinet.
(In other words, perform the reverse of Step 2.)
6. To remove the E2 port card, follow steps 2–5 in reverse order.
Fig. PC-3 (right) shows the configuration of a fully loaded ESI-100.
Note: For adding an ASC as the fifth card, see page G.8.
G.4
Fig. PC-3
ESI Communications Servers Hardware Installation Manual
ESI-100
Memory Module installation or replacement
Note: The Memory Module has a proprietary formatting scheme — do not attempt to install a non-ESI drive.
Contact ESI for a replacement Memory Module, if needed.
Adding or replacing the Memory Module will require that the ESI-100 be taken out of service.
All of the ESI-100’s configuration data and customer recordings are stored in the Memory Module.
Replacing it, therefore, requires re-programming and re-recording, unless you have previously performed a backup
using ESI System Programmer software. (Prompts stay intact, however.)
Note: Be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD) when
performing the following procedures; otherwise, circuit boards may suffer damage.
Install the CompactFlash Memory Module
1. Open the lid of the cabinet (you must remove
the screw on the top that secures the lid).
2. Power down the system.
3. Plug the Memory Module into the J14 connector
on the main board (see diagram, right).
4. Secure the lid to the KSU.
Remove the CompactFlash
Memory Module (if replacing)
1. Open the lid of the cabinet (you must remove
the screw on the top that secures the lid).
2. Power down the system.
3. Remove the Memory Module from the J14 connector on the main board (see diagram, right).
4. To install the Memory Module, follow the steps in “Install the CompactFlash Memory Module,” above.
G.5
ESI Communications Servers Hardware Installation Manual
ESI-100
LED functions
The unit's various LEDs are designed to provide visual feedback as follows:
Power LED
The Power LED is located on the right side of the Base Cabinet, and is illuminated when power is being
applied to the system. This LED blinks periodically to indicate that the main processor is operational.
Port LEDs
The Port LEDs are located above their respective connectors on each installed port card. Each LED is
illuminated when any port on its associated port card is in use.
Note: Disconnecting a connector when its respective LED is lit will disconnect any of its ports that are in use.
Upon power-up, approximately five minutes are required for the system to configure. The Power and Port
LEDs will blink three times to indicate that the power-up sequence has been completed.
Note: When a DLC’s LED is . . .
• . . . blinking, the T1/PRI circuit is out of service.
• . . . not lit at all, the T1/PRI circuit is in service but is idle.
• . . . lit solidly, the T1/PRI circuit and/or a station on the card are in use.
G.6
ESI Communications Servers Hardware Installation Manual
ESI-100
ESI Presence Management installation
For information on installing ESI Presence Management, see its Installation Manual (ESI # 0450-0792).
ESI Cellular Management installation
Hardware
The ESI Cellular Management Access Device (see graphic, below) is housed in a small, ergonomic plastic case,
which connects to a digital phone port. Although the Access Device is intended for desktop placement near
1
®
the host ESI phone , it can be attached to any surface by using the included Velcro strips.
The ESI Cellular Management Access Device is powered by the digital port.
Each ESI Cellular Management Access Device requires a single digital port. Only the number of available
station ports limits the number of ESI Cellular Management devices that can be connected to the system.
PAIRING
button
HANDSET LED
PC
2
jack
NETWORK
3
jack
DIGITAL
jack
Back panel.
Front panel.
HANDSET LED
A single blue HANDSET LED on the front panel of the ESI Cellular Management Access Device displays
the status of a Bluetooth-enabled cell phone as related to the ESI phone:
•
•
Off — Unpaired with a cellular phone.
Blinking slowly — Not connected (Auto-Connect disabled).
•
•
Blinking moderately — Searching for cell phone (not connected).
Blinking rapidly — In pairing mode.
•
On — Cell phone is paired and connected.
PAIRING button
The PAIRING button, on the rear of the Access Device, is used to initiate the pairing of a Bluetoothenabled handset and/or headset with ESI Cellular Management.
Jacks
The Access Device’s DIGITAL jack is an RJ-11 jack for connecting the Access Device to an ESI digital
port. Power is provided via the included 12-ft. line cord connection to an ESI digital port card.
The PC and NETWORK jacks are reserved for possible future use.
For information on installing ESI Cellular Management, see its Installation Guide (ESI # 0450-1155).
1
2
While it is possible to program ESI Cellular Management from a 24-Key Feature Phone, the use of certain ESI Cellular Management features is
possible only through the soft keys under the display of an ESI 60, ESI 40, or 48-Key Feature Phone.
Reserved for possible future use.
G.7
ESI Communications Servers Hardware Installation Manual
ESI-100
Installation of card(s) for ESI Mobile Messaging and SIP trunking
The following instructions cover installation of the CS-SIP24, CS-SIP8, and CS-ASC on an ESI-100 or ESI-50.
Important: Each card is for ESI Communications Servers only (except ESI-50L) and requires a Hot-Swap Port Card
Adapter (five-pack, ESI # 5000-0462) if used on an ESI-1000, ESI-600, or ESI-200.
Before installing, verify that the system is running the appropriate system software. If it isn’t, download the
correct version from the ESI Resellers’ Web site and install it on the system.
ALWAYS power-down the entire system (all Cabinets) BEFORE adding or replacing any hardware.
Also, be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD)
when performing the following procedures; otherwise, circuit boards may suffer damage.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
On the ESI-100 ONLY, if installing a CS-ASC as the fifth card, see “Fifth-card installation of CS-ASC
(ESI-100 only),” page G.9.
After removing the new card from the box, install it as follows:
1. Remove the locking screw (at the top of the cabinet, securing the cover),
and then remove the top cover by pressing down the locking tab and
pulling the top cover forward (Fig. C-1).
On each system, port cards are added in a “piggyback” fashion — i.e.,
port card 2 plugs into port card 1, port card 3 plugs into port card 2, etc.
(Neither the CS-SIP24 nor the CS-SIP8 nor the ASC may be in slot 1
on an ESI-100, and the ESI-50 main board contains a fixed 482 card.)
Use the following table and Fig. C-2 (below) to determine which
connectors to use in each case:
System
ESI-100
ESI-100
ESI-100
ESI-50
ESI-50
ESI-50
ESI-50
Figure C-1 (ESI-100 shown)
Connecting SIP/ASC to . . .
Use these respective connectors . . .
Main board
n/a (not permitted)
Another port card other than a CS-SIP24, CS-SIP8, or CS-ASC
J15 to J2
Another CS-SIP24, CS-SIP8, or CS-ASC
J15 to J16
Main board
J18 to J16
A 482 card (i.e., not the one built into the ESI-50 main board)
J18 to J6
A DLC82 card
J18 to J9
Another CS-SIP24, CS-SIP8, or CS-ASC
J18 to J17
2. A cable is attached to the correct connector of the new card. Connect the cable’s other end to the correct
connector of the cabinet’s existing port card.
3. Secure the card to the cabinet (Fig. C-2).
If it’s going into the top slot, use five screws.
If it’s going into the bottom slot, use five standoffs appropriately:
• 7/16-in. standoffs — Between the ESI-100 Base Cabinet and
the first card.
• 3/4-in. standoffs — Between the first and second card in the
ESI-100 Base Cabinet.
• 1-in. standoffs — Between port cards in either the ESI-100
Expansion Cabinet or the ESI-50.
Use the screws that ship with the card to secure the new card to
the standoffs. (You may have leftover screws.) DON’T overtighten the
standoffs; it will strip the plastic bosses.
Figure C-2
4. Put the top cover back on the cabinet, and then replace the locking screw to secure the cover on the
cabinet. (In other words, perform the reverse of Step 1.)
5. To remove the new card, follow steps 1–4 in reverse order.
G.8
ESI Communications Servers Hardware Installation Manual
ESI-100
Fifth-card installation of CS-ASC (ESI-100 only)
To install a CS-ASC as the fifth card in an ESI-100 (requires system software 12.5.41.0 or higher), attach a
second Expansion Cabinet to the Expansion Cabinet that you attached to the Base Cabinet, and install the
ASC in the second Expansion Cabinet as Port Card 5, as shown in the graphic below. Note that the left-most
slot in the second Expansion Cabinet, shown here as Slot #6, is unused.
Use of Ethernet connectors
• CS-SIP24 or CS-SIP8 — Both Ethernet® connectors must be connected to the private local area
network (LAN).
• ASC — Only Ethernet Connector #1 must be connected to the private LAN.
For information on programming ESI Mobile Messaging, see its Installation Guide (ESI # 0450-1231).
For information on installing SIP trunking, see the ESI SIP Trunking Installation Guide (ESI # 0450-1227).
G.9
ESI Communications Servers Hardware Installation Manual
ESI-100
Installation of Memory Module for CS-ASC
Important: The CS-ASC (Applications Services Card) is for ESI Communications Servers only (except ESI-50L) and
requires a Hot-Swap Port Card Adapter (five-pack, ESI # 5000-0462) if used on an ESI-1000, ESI-600, or
ESI-200.
Before installing, verify that the system is running the appropriate system software. If it isn’t, download the
correct version from the ESI Resellers’ Web site and install it on the system.
ALWAYS power-down the entire system (all Cabinets) BEFORE adding or replacing any hardware.
Also, be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD)
when performing the following procedures; otherwise, circuit boards may suffer damage.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
®
Installing the ASC Memory Module (hard drive) does not replace the CompactFlash (which is preinstalled).
What you’ll need
Here’s what you’ll need to install the ASC Memory Module (hard drive):
• -inch nut driver
• #1 Phillips screwdriver
• A clean, well-lit, and static-free work area
Procedure
After removing the new card from the box, install the Memory Module
as follows:
Figure H-1
1. Screw into the Memory Module the four -inch standoffs that came with the ASC Memory Module kit.
2. Align:
a. the threaded holes at the end of the hard drive subassembly’s standoffs
. . . to . . .
b. the four holes on the ASC (Fig. H-1).
3. Using the four remaining screws that came with the Memory
Module, attach the Memory Module to the ASC.
4. Connect the Memory Module’s hard drive cable (Fig. H-2) to
the appropriate connector (U12) on the ASC.
Note: To prevent the cable from interfering with insertion
of the main board, fold the cable in toward the
Memory Module as shown in Fig. H-2.
G.10
Figure H-2
ESI Communications Servers Hardware Installation Manual
ESI-50
Hardware installation: ESI-50
Site location
As with most electronic equipment, the environmental considerations for this site need to observe good common
sense. Provide a dry, clean, and accessible area.
Locate space in the telephone equipment room, which will provide easy connection to the 66 blocks and 110 VAC
power. The location should be no further than 1,000 feet from the farthest station.
0
0
Ambient room temperature must be 40 –80 (F.), and relative humidity no higher than 90%.
Notes: Do not place the equipment or run station cabling near high voltage electrical equipment or electrical lines
susceptible to high voltage surges from air conditioner compressors, etc.
Do not mount the equipment in a place that receives direct sunlight.
The system and supporting components should be mounted to a half-inch (or thicker) plywood backboard. Here is
the layout of a typical Base Cabinet installation.
ESI-50 Base Cabinet typical installation
H.1
ESI Communications Servers Hardware Installation Manual
ESI-50
Opening the Base Cabinet
The lid on the Base Cabinet is held in place by two tabs that rest in slots in the bottom
of the case, and a release tab that snaps into an opening in the top-center of the
cabinet and is secured by a retaining screw.
To remove the lid:
1. Remove the retaining screw and depress the release tab at the top of
the cabinet.
2. Rock the lid back from the top.
3. Lift and pull the lid free from the slots in the bottom of the cabinet.
Mounting the Base Cabinet
To mount the ESI-50 Base Cabinet, use the three provided #8 Phillips screws. Note the position of the three
mounting holes in the cabinet. Allow room for installation of the Expansion Cabinet (see page G.3) either now or,
if required, in the future.
1. Screw in the top screw to the backboard (at least half-inch thick
plywood) leaving about one-eighth-inch clearance between the
screw head and the plywood.
2. Hang the unit using the keyhole at the top of the case.
3. Level the unit and install the bottom two screws.
Attach the power transformer to the wall, allowing sufficient length in both cords to
reach the power connector on the upper right side of the cabinet and to reach a UPS
or a dedicated 110 VAC outlet.
H.2
Base Cabinet
ESI Communications Servers Hardware Installation Manual
ESI-50
Expansion Cabinet installation
The Expansion Cabinet allows the ESI-50’s capacity to grow by up to two additional port cards. The cards are
connected via ribbon cables, through the opening in the back of the Expansion Cabinet, to the Base Cabinet.
Note: You can add only one Expansion Cabinet to an ESI-50.
To install an Expansion Cabinet:
1. Wear a grounding strap and avoid unnecessary movement while
handling the circuit boards.
2. Unplug the power to the ESI-50 system.
3. Remove the Base Cabinet lid by pressing the release tab at the top of the
cabinet and rock back the lid from the bottom of the cabinet.
4. Install the Expansion Cabinet on the front of the Base Cabinet in place of
the Base Cabinet's lid.
5. Lock the Expansion Cabinet to the Base Cabinet by snapping the top in
place and reinstalling the retaining screw.
6. Connect the grounding strap from the Expansion Cabinet's grounding lug
(located on the bottom of the cabinet) to the Base Cabinet's grounding
lug. (See also “Grounding instructions,” page I.1).
7. Through the large opening in the back of the Expansion Cabinet,
connect the ribbon cable(s) from the port card(s) to the card
directly below.
8. Re-install the original lid from the Base Cabinet on the face of the
Expansion Cabinet.
Port card installation
Adding or replacing port cards will require the system to be taken out of service
(the ESI-50 doesn’t support “hot-swapping” of its port cards).
These instructions cover both types of ESI-50 port cards — the 482 card (used on all ESI-50 models) and the
1
DLC82 card (not compatible with the ESI-50L ). Each card has cable connectors in the same location, but the
connectors have different names depending on the card type:
•
•
On the 482 card, the connectors are J5 and J6, respectively.
On the DLC82 card, the connectors are J8 and J9, respectively.
Therefore, for brevity’s sake, these instructions and their diagram describe the connectors as J5/J8 and J6/J9.
Important: The ESI-50 can use only 482 and DLC82 port cards (see “Port card options,” beginning on page A.4).
ALWAYS power down the system BEFORE adding or replacing any hardware. Also, be sure to
observe all proper procedures regarding the prevention of electrostatic discharge (ESD) when performing the
following procedures; otherwise, circuit boards may suffer damage.
The DLC82 can be installed in ONLY slot 2.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
(Continued)
1
If installing the ESI-50L, consult the ESI-50L Hardware Installation Manual (0450-xxxx).
H.3
ESI Communications Servers Hardware Installation Manual
1. Remove the locking screw at the top of the Base Cabinet,
securing the cover, and remove the top cover by pressing
down the locking tab and pulling the top cover forward.
2. Connect the first port card by inserting the ribbon cable
from J5/J8 on the port card to J16 on the main board.
3. Secure the port card with the five screws that came with the
port card to the standoffs that came with the Base Cabinet.
4. If you’re installing a second port card, secure the
second port card to the Expansion Cabinet, using the
screws provided with the port card.
5. Connect the second port card by inserting the ribbon cable
from J5/J8 on the port card to J6/J9 on the first port card
(located in the Base Cabinet).
6. Attach the Expansion Cabinet to the Base Cabinet, and
secure with the locking screw at the top of the Base Cabinet.
7. Secure the lid to the KSU and/or Expansion Cabinet.
8. Reverse the steps to remove the port card. Remember
to power down the system before replacing parts.
The diagram at right shows the configuration of a fully loaded ESI-50.
H.4
ESI-50
ESI Communications Servers Hardware Installation Manual
ESI-50
Memory Module installation or replacement
Note: The Memory Module has a proprietary formatting scheme — do not attempt to install a non-ESI drive.
Contact ESI for a replacement Memory Module, if needed.
Adding or replacing the Memory Module will require that the ESI-50 be taken out of service.
All of the ESI-50’s configuration data and customer recordings are stored in the Memory Module. Replacing
it, therefore, requires re-programming and re-recording, unless you have previously performed a backup using ESI
System Programmer software. (Prompts stay intact, however.)
Note: Be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD) when
performing the following procedures; otherwise, circuit boards may suffer damage.
Install the CompactFlash Memory Module
1. Open the lid of the cabinet (you must remove
the screw on the top that secures the lid).
2. Power down the system.
3. Plug the Memory Module into the J11 connector
on the main board (see diagram, right).
4. Secure the lid to the KSU.
Remove the CompactFlash
Memory Module (if replacing)
1. Open the lid of the cabinet (you must remove
the screw on the top that secures the lid).
2. Power down the system.
3. Remove the Memory Module from the J11 connector on the main board (see diagram, above).
4. To install the Memory Module, follow the steps in “Install the CompactFlash Memory Module,” above.
H.5
ESI Communications Servers Hardware Installation Manual
ESI-50
LED functions
The unit's various LEDs are designed to provide visual feedback as follows:
Power LED
The Power LED is located on the right side of the Base Cabinet, and is illuminated when power is being
applied to the system. This LED blinks periodically to indicate that the main processor is operational.
Port LEDs
The Port LEDs are located above their respective connectors on each installed port card. Each LED is
illuminated when any port on its associated port card is in use.
Note: Disconnecting a connector when its respective LED is lit will disconnect any of its ports that are in use.
Upon power-up, approximately five minutes are required for the system to configure. The Power and Port
LEDs will blink three times to indicate that the power-up sequence has been completed.
1
Note: When the LED on a DLC is . . .
• . . . blinking, the T1/PRI circuit is out of service.
• . . . not lit at all, the T1/PRI circuit is in service but is idle.
• . . . lit solidly, the T1/PRI circuit and/or a station on the card are in use.
1
The DLC82 for the ESI-50 supports only PRI (not T1). DLCs for other ESI Communications Servers support both T1 and PRI. Please note also that
the DLC82 is for only the ESI-50 and not the ESI-50L.
H.6
ESI Communications Servers Hardware Installation Manual
ESI-50
ESI Presence Management installation
For information on installing ESI Presence Management, see its Installation Manual (ESI # 0450-0792).
ESI Cellular Management installation
Hardware
The ESI Cellular Management Access Device (see graphic, below) is housed in a small, ergonomic plastic case,
which connects to a digital phone port. Although the Access Device is intended for desktop placement near
®
the host ESI phone, it can be attached to any surface by using the included Velcro strips.
The ESI Cellular Management Access Device is powered by the digital port. Each ESI Cellular Management
Access Device requires a single digital port. Only the number of available station ports limits the number of
ESI Cellular Management devices that can be connected to the system.
PAIRING
button
HANDSET LED
PC
jack
NETWORK
jack
DIGITAL
jack
Back panel.
Front panel.
HANDSET LED
A single blue HANDSET LED on the front panel of the ESI Cellular Management Access Device displays
the status of a Bluetooth-enabled cell phone as related to the ESI phone:
•
•
Off — Unpaired with a cellular phone.
Blinking slowly — Not connected (Auto-Connect disabled).
•
•
Blinking moderately — Searching for cell phone (not connected).
Blinking rapidly — In pairing mode.
•
On — Cell phone is paired and connected.
PAIRING button
The PAIRING button, on the rear of the Access Device, is used to initiate the pairing of a Bluetoothenabled handset and/or headset with ESI Cellular Management.
Jacks
The Access Device’s DIGITAL jack is an RJ-11 jack for connecting the Access Device to an ESI digital
port. Power is provided via the included 12-ft. line cord connection to an ESI digital port card.
The PC and NETWORK jacks are reserved for possible future use.
For information on installing ESI Cellular Management, see its Installation Guide (ESI # 0450-1155).
H.7
ESI Communications Servers Hardware Installation Manual
ESI-50
Installation of card(s) for ESI Mobile Messaging and SIP trunking
The following instructions cover installation of the CS-SIP24, CS-SIP8, and CS-ASC on an ESI-100 or ESI-50.
Important: Each card is for ESI Communications Servers only (except ESI-50L) and requires a Hot-Swap Port Card
Adapter (five-pack, ESI # 5000-0462) if used on an ESI-1000, ESI-600, or ESI-200.
Before installing, verify that the system is running the appropriate system software. If it isn’t, download the
correct version from the ESI Resellers’ Web site and install it on the system.
ALWAYS power-down the entire system (all Cabinets) BEFORE adding or replacing any hardware.
Also, be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD)
when performing the following procedures; otherwise, circuit boards may suffer damage.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
After removing the new card from the box, install it as follows:
1. Remove the locking screw (at the top of the cabinet, securing the cover),
and then remove the top cover by pressing down the locking tab and
pulling the top cover forward (Fig. C-1).
On each system, port cards are added in a “piggyback” fashion — i.e.,
port card 2 plugs into port card 1, port card 3 plugs into port card 2, etc.
(Neither the CS-SIP24 nor the CS-SIP8 nor the ASC may be in slot 1
on an ESI-100, and the ESI-50 main board contains a fixed 482 card.)
Use the following table and Fig. C-2 (below) to determine which
connectors to use in each case:
System
ESI-100
ESI-100
ESI-100
ESI-50
ESI-50
ESI-50
ESI-50
Figure C-1 (ESI-100 shown)
Connecting SIP/ASC to . . .
Use these respective connectors . . .
Main board
n/a (not permitted)
Another port card other than a CS-SIP24, CS-SIP8, or CS-ASC
J15 to J2
Another CS-SIP24, CS-SIP8, or CS-ASC
J15 to J16
Main board
J18 to J16
A 482 card (i.e., not the one built into the ESI-50 main board)
J18 to J6
A DLC82 card
J18 to J9
Another CS-SIP24, CS-SIP8, or CS-ASC
J18 to J17
2. A cable is attached to the correct connector of the new card. Connect the cable’s other end to the correct
connector of the cabinet’s existing port card.
3. Secure the card to the cabinet (Fig. C-2).
If it’s going into the top slot, use five screws.
If it’s going into the bottom slot, use five standoffs appropriately:
• 7/16-in. standoffs — Between the ESI-100 Base Cabinet and
the first card.
• 3/4-in. standoffs — Between the first and second card in the
ESI-100 Base Cabinet.
• 1-in. standoffs — Between port cards in either the ESI-100
Expansion Cabinet or the ESI-50.
Use the screws that ship with the card to secure the new card to
the standoffs. (You may have leftover screws.) DON’T overtighten the
standoffs; it will strip the plastic bosses.
Figure C-2
4. Put the top cover back on the cabinet, and then replace the locking screw to secure the cover on the
cabinet. (In other words, perform the reverse of Step 1.)
5. To remove the new card, follow steps 1–4 in reverse order.
H.8
ESI Communications Servers Hardware Installation Manual
ESI-50
Use of Ethernet connectors
• CS-SIP24 or CS-SIP8 — Both Ethernet® connectors must be connected to the private local area network
(LAN).
• ASC — Only Ethernet Connector #1 must be connected to the private LAN.
For information on programming ESI Mobile Messaging, see its Installation Guide (ESI # 0450-1231).
For information on installing SIP trunking, see the ESI SIP Trunking Installation Guide (ESI # 0450-1227).
Installation of Memory Module for CS-ASC
Important: The CS-ASC (Applications Services Card) is for ESI Communications Servers only (except ESI-50L) and
requires a Hot-Swap Port Card Adapter (five-pack, ESI # 5000-0462) if used on an ESI-1000, ESI-600, or
ESI-200.
Before installing, verify that the system is running the appropriate system software. If it isn’t, download the
correct version from the ESI Resellers’ Web site and install it on the system.
ALWAYS power-down the entire system (all Cabinets) BEFORE adding or replacing any hardware.
Also, be sure to observe all proper procedures regarding the prevention of electrostatic discharge (ESD)
when performing the following procedures; otherwise, circuit boards may suffer damage.
Whenever you change the port card configuration, you must create a backup file for the new configuration
to be able to perform the Restore function later.
®
Installing the ASC Memory Module (hard drive) does not replace the CompactFlash (which is preinstalled).
What you’ll need
Here’s what you’ll need to install the ASC Memory Module (hard drive):
• -inch nut driver
• #1 Phillips screwdriver
• A clean, well-lit, and static-free work area
Procedure
After removing the new card from the box, install the Memory Module
as follows:
Figure H-1
1. Screw into the Memory Module the four -inch standoffs that came with the ASC Memory Module kit.
2. Align:
a. the threaded holes at the end of the hard drive subassembly’s standoffs
. . . to . . .
b. the four holes on the ASC (Fig. H-1).
3. Using the four remaining screws that came with the Memory
Module, attach the Memory Module to the ASC.
4. Connect the Memory Module’s hard drive cable (Fig. H-2) to
the appropriate connector (U12) on the ASC.
Note: To prevent the cable from interfering with insertion
of the main board, fold the cable in toward the
Memory Module as shown in Fig. H-2.
H.9
Figure H-2
ESI Communications Servers Hardware Installation Manual
External connections
External connections
Grounding instructions
System grounding (supplemental ground) is as follows:
•
•
The conductor wires can be no smaller than the ungrounded branch-circuit supply conductors (usually 16gauge or higher).
Acceptable wire: bare or covered with green (or green-and-yellow-striped) jacket.
•
Conductors (and power receptacles) shall connect to earth ground at the service equipment (usually a cold
water pipe or copper ground rod).
•
The supplemental ground must: be used regardless of power cord ground, be connected to the ground lug
on the bottom of the cabinet, and retain ground connection when the power supply module is unplugged.
Connect the grounding lugs of all units to system ground
•
Note: ESI Communications Server lines are protected against a 10 KV surge only if the earth ground procedures
described above are followed.
Power
Each cabinet requires a 110 VAC outlet (if possible, a dedicated outlet). Use only the Class-2 power supply
module provided. A clean, isolated power source in conjunction with a UPS is STRONGLY recommended.
The following table shows the power consumption of each ESI Communications Server when fully loaded:
System
ESI-1000
ESI-600
ESI-200
ESI-100
ESI-50
Cabinets (Base and Expansion)
in fully loaded system
6
4
2
3
2
Power consumption
(in watts)
1,080
720
360
125
72
If AC power is interrupted, the system will drop all connections. When power is restored, the system will resume
normal operation in approximately five minutes, having retained its full programming and clock setting.
UPS
For system protection and to maintain uninterrupted operation, an uninterruptible power supply is
STRONGLY recommended. Here are the recommended UPS ratings for each system:
System
ESI-1000
ESI-600
ESI-200
ESI-100
ESI-50
Recommended UPS minimum rating
PER INSTALLED CABINET (in VA)
230
230
230
125
125
Refer to the particular UPS unit’s specifications to determine expected backup duration during a power outage.
Note: The remaining information under “UPS” comes from Technical Update #216.
Most people have heard about UPSs, but seem to think that there is just one kind of device that goes by that
name. In fact, there are several different major designs in use by today’s major UPS manufacturers. These
makers share much of the blame for confusing UPSs’ end users by, far too often, lumping different designs
under the “UPS” name.
(Continued)
I.1
ESI Communications Servers Hardware Installation Manual
External connections
UPSs can first be broken down into system types:
• Stand-by — A very simple design that affects power only when either a lag/brownout occurs below, or a
spike/surge occurs above, a certain threshold. When either occurs, the unit trips — i.e., goes into battery
mode. This "cleans" the voltage and helps to keep any load safe. Industry average "trip" times are 2–8
ms. No other filtration of AC power is performed.
• Line interactive — Constantly monitors inbound voltages, and uses special circuitry to boost low voltages
and clamp high voltages without having to use the batteries. Indeed, the batteries are used only if the
input voltage drops below acceptable levels (typically about 12% below normal), goes out completely or
rises to dangerous levels (typically about 14% above normal) at which components will be damaged if line
voltage is not removed. Industry average transfer time is 1–3 ms. (If voltage stays within its normal
window, this unit continues to pass voltage, unaltered, from the wall.)
• On-line (or full on-line) — Constantly filters the power and performs a function known as double
conversion (AC to DC to AC). This assures that the load — in this case, phone equipment — will receive
not only uninterrupted, true sine wave output but also the cleanest, steadiest power possible throughout
any foreseeable power disruptions or voltage irregularities. According to industry specs, it is not unusual
for these types of units to be able to regulate utility power, even when it drops to 27% below or rises to
33% above normal, all without using their batteries.
From this point, UPSs can be further broken down by inverter types, which determine output. These are:
• Square wave.
• Modified sine wave (or quasi sine wave).
• Sine wave.
Most devices with wall-mounted chargers, such as cordless drills or screwdrivers, can behave erratically —
sometimes not allowing the charge circuit to engage at all — when operating with modified sine or square
wave inverters. Small wall-based transformer-style power supplies, similar to those ESI phone systems use,
can experience overheating problems with modified sine or square wave outputs, which occur while some
UPSs are operating in battery mode. This overheating could eventually cause damage to the power supplies;
and, in time, the damage could cause a spike through the phone system — seriously damaging some of the
static-sensitive components inside the casing.
While the true sine wave UPS output power curve smoothly increases to its peak, then smoothly
decreases (allowing connected loads and equipment to operate the same as they would from utility supplied
wall power), the modified sine wave and square wave UPS output power curve will shoot straight up, level off
at peak voltage and then drop straight down. Additionally troublesome is that the modified sine wave sits at
zero voltage for a short period during the transition to or from batteries — which is the main difference
between it and the square wave output of some UPS. Please note that this short interval during which the
modified sine wave UPS sits at zero voltage can directly affect the transfer time of the UPS and could,
theoretically, be enough to cause the phone equipment to reset or even “freeze.”
Though it is hard to predict exactly when different ESI systems will have problems with modified sine wave or
square waveform UPSs (meaning during a power failure event or the recovery from one), it’s fair to assume
that a problem will eventually arise from the use of such UPSs. Therefore, ESI recommends that only true
sine wave output UPSs provide backup power to our phone systems and equipment.
I.2
ESI Communications Servers Hardware Installation Manual
External connections
MOH port
The MOH (messages-, or music-, on-hold) connector — located on the main board faceplate (ESI-1000, ESI1
600, and ESI-200) or the Base Cabinet’s right side (ESI-100) — is a standard /8″ monophonic mini-jack, used for
loading custom MOH recordings or for playing live music-on-hold from an external source such as a CD player.
Maintenance/SMDR serial port
The Maintenance/SMDR port is a standard DB9 female serial connector, located on the main board faceplate
(ESI-1000, ESI-600, and ESI-200) or the Base Cabinet’s right side (ESI-100 and ESI-50). Use a standard
shielded serial cable, DB9-to-DB9, for printer-to-computer; this is usually male-to-female.
Note: The maximum distance from the cabinet is 100 ft.
The output from the Maintenance/SMDR port is, 8 data bits, 1 stop bit, and no parity. The pinout is:
Data Transmit
Pin 2
Receive
Pin 3
Ground
Pin 5
To program this port, use Function 18 as described in the ESI Communications Servers Programming Manual
(ESI #0450-1050).
Range: Programmable for 300, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, or 115,200 bps.
Default: 38.4K.
Maintenance
Connect a PC (such as a laptop) to the port to perform on-line programming and diagnostics. Also, the
system sends reports to this port.
SMDR
The ESI Communications Server continuously outputs real-time SMDR call records to the port.
Note: The system will buffer up to a specific limit of SMDR records (60,000 on the ESI-1000, or 1,000 on other
ESI Communications Servers) in non-volatile memory when the Maintenance/ SMDR serial port is in
use for programming or uploading (such as during use of ESI System Programmer). If the buffer
becomes full, the system will discard the oldest records.
For more information about the Maintenance/SMDR port, see “SMDR” in the ESI Communications Servers
Programming Manual (ESI #0450-1050).
I.3
ESI Communications Servers Hardware Installation Manual
External connections
External paging device connection
ESI-1000 and ESI-600, and ESI-50
On either of these systems, a dry-contact overhead-paging device can be connected
through the RJ-11 OH Paging connector, which is located on the front of the main board
faceplate just below the NSP’s Ethernet connector. Although this is a six-pin connector, only two pairs are
needed between the paging device and the connector:
• To pin-out the connector for normally open operation, connect the audio wires to pins 3 and 4 and the
control pair to pins 1 and 2.
• To pin-out the connector for normally closed operation, connect the audio wires to pins 3 and 4 and the
control pair to pins 5 and 6.
ESI-200 and ESI-100
1
A dry contact overhead-paging device can be connected to the system through the first port card's 66 block.
The overhead paging port is fixed (located on the main board) as code 599 for programming purposes and
user access. (See “Worksheet” wiring charts, page I.23.)
Audio connection
The audio pair is connected to the 66 block at terminal 33 and 34. The pair’s impedance is 600 ohms.
Note: The port doesn’t support talk-back paging (which requires a CO port), nor does it support CO ring
through the port.
Dry-contact control
The manner in which the dry-contact pair is punched down on the 66 block sets the pair as normally open
(sending a page to the port will close the contacts) or normally closed (sending a page to the port will open
the contacts).
Connect the dry-contact pair of the device to the ESI Communications Server as follows:
•
•
Terminals 35 and 36 to provide normally open operation;
or
Terminals 36 and 38 to provide normally closed operation.
The port can be used with zone paging units.
Note: ESI doesn’t recommend the use of paging contacts for door-unlocking mechanisms.
Programming
To access the overhead paging port, assign feature code 5 9 9 to a programmable feature key.
Amphenol cable connections
Connect a standard 66 or 110 block to each digital port card by using a male 50-pin amphenol cable to each port
card female connector located on the cabinet. On the ESI-100 or ESI-50, the connector closest to the wall is the
first card; on other ESI Communications Servers, the connector in the leftmost slot is the first card.
1
If an IVC is installed in slot 1 on the ESI-1000, ESI-600, or ESI-200, the audio connection and dry-contact control connect via the second port card.
(On an ESI-200, a non-IVC card must be in slot 1 or 2. On an ESI-100, a non-IVC card must be in slot 1. On an ESI-50, an IVC is built-in and
considered to be port card 2.)
I.4
ESI Communications Servers Hardware Installation Manual
External connections
CO line connection
Note: For greatest simplicity, this section mentions each port card without the use of an “ESI,” “E2-,“ or “CS-“
prefix, as cards otherwise are functionally identical — e.g., we refer to an E2-684 or CS-684 as just a “684.”
Local loop
An ESI Communication Server’s advanced CO line circuitry provides for open loop detection and the
system’s built-in Caller ID interface. Loop start lines are connected via the last 6 pairs on each 66 block on the
612 and 684 cards.
Note: Observe correct order of connection to preserve proper rotary hunting of the CO lines.
T1/PRI
For T1 or PRI applications (only PRI on the ESI-50; it doesn’t support T1), an ESI Communications Server
1
can use a compatible digital line card (DLC) :
• ESI-1000, ESI-600, ESI-200, ESI-100 — DLC and DLC12, each for either T1 or PRI.
• ESI-50 — DLC82 for only PRI.
Depending on how you configure it, each supports either (a.) a single T1 circuit at 24 DS0 channels or (b.) a
PRI circuit supporting 23 “B” (bearer) channels and one “D” (data link) channel. The DLC12 and DLC82 each
also support 12 digital stations. The T1 or PRI line is connected via the last two pairs of the industry-standard
50-pin amphenol cable connector on the front of the DLC.
Each ESI Communications Server has a different maximum number of system-wide DLCs (see “Port card
options,” page A.4). Partial T1 or PRI applications are supported through line programming.
Each DLC has built-in CSU functionality. The integrated CSU can be enabled or disabled via system
2
programming . The following functionality is provided: line, payload, DTE and none (normal operation)
loopback modes with the ability to respond back controlled via system programming; alarm conditions, and
both ANSI T1.403 and TR 54016 performance messages for ESF only.
Important: On the ESI-50, the DLC82 may be installed in only slot 2.
If you’re installing more than one T1 or PRI, the DLC in the lowest number slot will synchronize (“slave”)
the system with the public network. The system will synchronize to only one clock source. Therefore, ESI
strongly recommends that the first DLC in the system be connected to the T1 or PRI that’s connected
either to the local CO or the nationwide long-distance provider, either of which typically will provide veryhigh-accuracy clocking (Strata 3). The DLC doesn’t provide master or sub-master clocking for privatenetwork T1 spans.
(Continued)
1
2
You may wish to review “Port card options,” page A.4.
See the explanation of Function 2124 in the ESI Communications Servers Programming Manual (ESI #0450-1050).
I.5
ESI Communications Servers Hardware Installation Manual
External connections
1
When working with a T1 line , the DLC or DLC12 supports these trunk types:
• Loop start
• Ground start
• E&M (including E&M–DID/DNIS/ANI) — When an E&M trunk is selected, the choices for outgoing
signaling type are immediate start, wink start and dial tone start; and the incoming signaling type choices
are immediate start and wink start. The E&M trunk can be set for 2-way traffic, inbound traffic only or
outbound traffic only.
The DID and DNIS/ANI translation table allows the translation of DID/DNIS digits to an ID, mailbox, extension
or department. See below for the number of entries that can be programmed in the table:
System
ESI-1000
ESI-600
ESI-200
ESI-100
ESI-50
Maximum DID entries
1,200
600
300
300
300
There is also an entry for exceptions in the table. This allows reroutes of any DID/DNIS calls that aren’t
programmed or detected to an ID, mailbox, extension or department and defaults to the operator.
The card supports the following framing format and line coding:
•
•
•
•
ESF/B8ZS (default)
SF(D4)/AMI
ESF/AMI
SF/B8ZS
Line compensation (or line build-out) is provided as necessary between the CSU or Smart Jack™ and the
ESI Communications Server. There won’t be any support for pulse dialing; all incoming dialing will default to
DTMF digits.
When working with a PRI line, the DLC (i.e., the DLC, DLC12, or DLC82) supports these switch protocols:
•
•
•
•
National-NI2 (default)
Nortel-DMS100
AT&T/Lucent-5ESS
Siemens-EWSD
DID for the PRI is an enable/disable field. When DID is enabled, the PRI pilot table becomes active and works
in combination with the DID tables.
SIP trunks
For SIP trunking applications, an ESI Communications Server must use a compatible SIP24 or SIP8 card.
Each ESI Communications Server has a different maximum number of system-wide SIP24s or SIP8s (see
“Port card options,” page A.4). Partial SIP applications are supported through line programming.
Supported SIP trunks are:
• Broadvox ND
• Broadvox NS
1
Not supported by the ESI-50.
I.6
ESI Communications Servers Hardware Installation Manual
External connections
Station connection
Except on the 482 card (ESI-50 only1), the first 12 pairs on each Amphenol are station ports:
Port card
612
D12
DLC12
684
A12
A4
482
DLC82
Digital stations
12
12
12
8
8
8
Analog ports
ESI Communications Servers supporting
ESI-1000, ESI-600, ESI-200, ESI-100
ESI-1000, ESI-600, ESI-200, ESI-100
ESI-1000, ESI-600, ESI-200, ESI-100
ESI-1000, ESI-600, ESI-200, ESI-100
ESI-1000, ESI-600, ESI-200, ESI-100
ESI-1000, ESI-600, ESI-200, ESI-100
1
ESI-50
ESI-50
4
12
4
4
2
All stations are connected using a single pair. Each port position is pre-numbered and fixed as indicated in the
66 block wiring diagram shown for each port card type.
Note:
The station runs can be up to 1,000 ft.
Digital stations
Digital stations for the ESI Communications Server include:
•
•
ESI desktop phones
ESI Digital Cordless Handset
(II and original)
2
•
ESI Presence Management RFID Readers
•
3
ESI Cellular Management Access Devices
The digital station wiring is not polarity-sensitive. Only one phone can be connected per digital port.
The station line voltage is 33 VDC.
For proper operation, the combined length of
feed cables, backbone cabling, cross-connect,
and station cable must not exceed 1000 feet
(304 meters) for digital stations. Station line cord
length should not exceed 12 feet (note that this is
the length of the line cord provided with
each ESI desktop phone).
Each digital station can have no more than two
cross-connects or splices in the cable distribution.
Cable construction, termination blocks, and
modular jacks must meet at minimum Category 3
cabling requirements. Additional splices or
terminations will further reduce the maximum
cable length at which the digital station will operate reliably.
Because of potential interference caused by electrical noise, ESI strongly
recommends against distribution of digital stations with analog stations, T1 circuits, PRI circuits, or other
circuits in the same cable binder or station run.
Analog ports
The analog ports do not require that tip-and-ring polarity be observed. The analog ports can be used for
2500-type sets or for devices such as fax machines, modems, etc., that can be connected via a normal
tip-and-ring pair. Each analog port will support only a single analog device. (For total analog port capacity on
each ESI Communications Server, see “System capacities,” page D.1.)
All analog ports provide Type I Caller ID information (Caller ID with call waiting is not supported).
1
2
3
The 482 card is supported also by the ESI-50L, the ESI C-Plus, and IVX S-Class (Generation I–II) systems.
For information on installing ESI Presence Management, see its Installation Manual (ESI # 0450-0792).
For information on installing ESI Cellular Management, see its Installation Guide (ESI # 0450-1155).
I.7
ESI Communications Servers Hardware Installation Manual
External connections
60-Key Expansion Console connection
Notes: The 60-Key Expansion Console can be connected to an ESI 60, ESI 40, or 48-Key Feature Phone.
If connecting both a 60-Key Expansion Console and a 60-Key Second Expansion Console to an ESI phone,
see “60-Key Second Expansion Console connection,” page I.9.
1. The 60-Key Expansion Console (right) includes an expansion cable.
Connect one end of the expansion cable to the appropriate connector
on the bottom of the ESI phone (below). Then, connect the other end
of the expansion cable to the 60-Key Expansion Console.
2. To keep cabling out of the way, thread the expansion cable into the
slots on the bottom of the phone and 60-Key Expansion Console.
3. Program the keys on the 60-Key Expansion Console using the same
procedure as with the ESI phone (press PROG/HELP 2).
4. If necessary, remove the clear plastic overlay from the keys on the
Expansion Console.
5. For the customer’s convenience, label the paper overlay to show how
the keys are programmed (we suggest you use ESI System Programmer
for this).
6. Install the labeled paper overlay on the 60-Key Expansion Console.
7. Install the clear plastic overlay over the paper overlay, to protect it.
®
8. Use the provided Velcro tape to attach the left side of the 60-Key Expansion Console to the right side of
the ESI phone.
Connectors on bottom of
ESI 60 or ESI 40
Connectors on bottom of
48-Key Feature Phone
I.8
ESI Communications Servers Hardware Installation Manual
External connections
60-Key Second Expansion Console connection
Notes: If connecting only one Expansion Console to an ESI phone, see “60-Key Expansion Console connection,”
page I.8.
The 60-Key Second Expansion Console connects to the 60-Key Expansion Console and cannot connect
directly to any ESI phone to which you can connect a 60-Key Expansion Console.
1. The Second Expansion Console (which
is physically identical to a 60-Key
Expansion Console) includes an
1
expansion “Y” cable (right) .
Lay out the cable across the back
of the equipment so that the
AC adapter is on left and the end of
the cable is on the right.
2. Connect the right end of the
expansion “Y” cable to the appropriate
connector on the bottom of the ESI phone (below).
3. Then, connect the expansion “Y” cable’s middle plug to the 60-Key Expansion Console, the left plug to
the Second Expansion Console, and the AC adapter to an appropriate 110 VAC outlet to provide power to
the Second Expansion Console (above).
4. To keep cabling out of the way, thread the expansion “Y” cable into the slots on the bottom of the phone
and the two Expansion Consoles.
5. Program the keys on the two Expansion Consoles using the same procedure as with the ESI phone (press
PROG/HELP 2).
6. If necessary, remove the clear plastic overlay from the keys on the two 60-Key Expansion Consoles.
7. For the customer’s convenience, label the paper overlay to show how the keys are programmed (we suggest
you use the ESI System Programmer PC software application for this).
8. Install the labeled paper overlays on the two 60-Key Expansion Consoles.
9. Install the clear plastic overlays over the paper overlays, to protect them.
®
10. Use the provided Velcro tape to attach the left side of the 60-Key Expansion Console to the right side of
the ESI phone, and the right side of the 60-Key Expansion Console to the left side of the Second
Expansion Console).
Connectors on bottom of
ESI 60 or ESI 40
1
Connectors on bottom of
48-Key Feature Phone
This diagram shows the backs of the Expansion Consoles.
I.9
ESI Communications Servers Hardware Installation Manual
External connections
Installing ESI’s Cordless Handsets
Note: Except where noted, this section applies to both the ESI Cordless Handset II and original ESI Cordless
Handset models.
Each ESI Cordless Handset comes with:
•
A charger/cradle to charge the Handset.
•
An AC adapter for use with only the charger.
•
A base station to provide a digital interface between the ESI phone system and ESI Cordless Handset.
This base station needs no AC power: if the Cordless Handset is digital, the base station is line-powered;
if the Cordless Handset is IP, the base station uses Power over Ethernet (PoE).
Wall-mount(s), a belt clip, and a Quick Reference Guide.
•
Each ESI Cordless Handset is keyed to only one base station and takes up one port (digital or IP) on a port card.
Base station installation
Due to each site’s unique characteristics, the range and distance information we’ll provide herein is
only approximate.
Characteristics that positively affect performance:
• The base station should be installed so it has a clear line-of-sight with the Cordless Handset.
• The base station antenna should always be pointed in its uppermost vertical position.
Characteristics that negatively affect performance:
• Large amounts of metal shelving (such as in manufacturing or warehouse areas).
• Close proximity to (within one mile of) a radio tower.
• Concrete walls that divide spaces where Cordless Handsets are used (assuming the base stations are in
one location).
Don’t install the base station:
• Close to a wall with metal studs.
• On a metal wall.
• Next to a device that emits RFI or EMI1 — e.g., a television, radio, computer, computer printer,
fluorescent light fixture, or fax machine.
• Next to any other 900 MHz device — e.g., a hand-held inventory control device.
• In a ceiling that has foil-backed insulation.
• Behind doors that typically are closed, tinted windows, one-way glass, or other areas that limit or
cut off transmission to the Cordless Handset.
Base stations must be installed at least 10 feet apart, regardless of whether the base station is for the
small-model or large-model Cordless Handset. Don’t install more than six base stations in one area
(such as a network room). Choose a location at least 30 feet away if more than six base stations are needed
in a building.
(Continued)
1
RFI is radio frequency interference. EMI is electromagnetic interference.
I.10
ESI Communications Servers Hardware Installation Manual
External connections
A Digital Cordless Handset base station requires only a line cord to the phone system; AC power isn’t
needed because the base station receives power from the phone system via the line cord.
An IP Cordless Handset base station receives PoE. If PoE
isn’t already being supplied, you’ll need to install the
separately purchased PoE adapter (sold in five-packs
as ESI part # 5000-0437). The diagram at right shows the
necessary connections.
Note: If the PoE equipment plugs into AC outlets
and a power failure occurs, all IP Cordless
Handsets on the system will be unable to
originate or receive phone calls. Therefore,
either: (a.) use an appropriately sized
uninterruptible power supply (UPS) to
power all the IP equipment (base station,
PoE adapter, router, etc.) involved in
making phone calls or (b.) have a
traditional POTS (“plain old telephone
service”) phone available for originating
and receiving analog CO calls.
Once the base stations are installed and the Cordless Handsets charged:
• Cordless Handset II — The Cordless Handset II will auto-seek an available channel.
• Original Cordless Handset — Change each Handset’s channel by pressing its CH key. Each Handset
should have its own channel. There are 30 available channels on the small Cordless Handset and 10
on the large Cordless Handset.
Note: Feedback may result if the Cordless Handset is within three inches of an ESI desktop phone.
ESI Cordless Handset II Repeater
The optional ESI Cordless Handset II Repeater extends the coverage area of the ESI Cordless Handset II in
all directions, including up and down.
If Repeaters are installed so their coverage area overlaps that of the base station, the base station can hand
off calls to the Repeaters as the user moves from one coverage area to another. When it’s connected to a
Repeater, the ESI Cordless Handset II operates exactly as it does when connected to its base station, and
the handoff from the base station to the Repeater occurs seamlessly without disturbing the end user, even
during an active call.
Each ESI Cordless Handset II base station supports up to six repeaters, regardless of configuration.
• Each Repeater supports up to two direct connections to other Repeaters.
• No Repeater can be more than three connections — or hops — from the base station.
All Repeaters, regardless of configuration, must be registered to the base station.
Repeaters that are registered directly to a base
station (left), do not require use of the optional
Repeater Configurator Kit. These Repeaters
can be installed using automatic configuration.
However, Repeaters registered to the base
station through another Repeater (one
example shown, right) do require use of the
Repeater Configurator Kit.
For detailed information on installing Repeaters, refer to the ESI Cordless Handset II
Repeater Installation Manual (ESI # 0450-1248).
I.11
ESI Communications Servers Hardware Installation Manual
External connections
Repeater installation notes
To achieve optimum operation from your ESI Cordless Handset II Repeater:
•
Place the Repeater at least six feet off the ground so it has a clear line-of-sight.
•
Make sure the Repeater has good reception from the base station (or Repeater to which it is
daisy-chained).
Make sure the Repeater location is close to a standard 120 VAC power outlet.
•
•
Never install electrical cords across traffic areas where they can cause a tripping hazard (additionally,
such cords, if damaged, may create fire or electrical hazards).
•
Allow at least 35 feet between Repeaters.
If you install Repeaters across multiple floors, be sure to allow 35 feet vertically, too.
•
Install the Repeater away from sources of electrical interference. Examples include audio systems,
office equipment, and microwave ovens.
•
Install the Repeater away from heat sources and direct sunlight.
•
Install the Repeater away from items that can interfere with radio signals. Examples include metal
doors, thick walls, niches, and cupboards.
In case of trouble
If you have followed the guidelines described herein and still encounter problems with ESI Cordless Handsets,
please call ESI Technical Support at 800 491-3609 or e-mail to [email protected]. When contacting
ESI Technical Support, be sure to have as much of the following site and usage information as possible:
• Square footage of the building.
• Layout of building/offices, and locations of base stations and repeaters. This can be a hand-drawn
diagram with locations of base stations (you can fax it to ESI at 972 422-9705; be sure to indicate that it
goes to Technical Support). The objective is to give the ESI technician an idea of the site’s layout.
• Number of Cordless Handsets, whether they are Cordless Handsets II or original Cordless Handsets, and
how many are of each type (digital, Local IP, or Remote IP).
• How the troublesome Cordless Handset is being used. For example, is it used by a supervisor who travels
the entire area of the building many times per day, or by an administrative assistant to go a short distance
from an office to a copy room?
• Where the problem occurs — e.g., if a Cordless Handset cuts in and out when used in a certain area of
the building.
ESI Cordless Handset specifications
Fully charged battery time
Recharge time
Standby time
2
Approximate range
Weight (including battery)
Size, W D H (in.)
ESI Cordless
Handset II
Approx. 16. hrs.
1
5–8 hrs.
Approx. 7 days
Without Repeater: 175 ft.
With Repeater: 320 ft.
5.4 ozs.
2.25 1.25 6.5
Original ESI Cordless Handsets
Small Handset
Large Handset
Approx. 7 hrs.
Approx. 10 hrs.
Approx. 5 hrs.
Approx. 5 hrs.
Approx. 5 days
Approx. 4 days
200 ft.
400 ft.
5.2 oz.
2 1.25 5.5 w/o antenna
8.8 oz.
2.2 1.67 8.67 w/ antenna
Accessories
ESI sells separately a headset for both ESI Cordless Handset models, and this is the only headset ESI
supports for use with the ESI Cordless Handset. For more information on accessories for ESI Cordless
Handsets, refer to your appropriate Price Schedule, the ESI Cordless Handset II Product Overview
(ESI # 0450-1228), or the ESI Cordless Handset Product Overview (ESI # 0450-0840).
1
2
If charged while in the handset. A battery pack placed in the charger’s extra-battery compartment requires 15–19 hours to recharge.
Interference may result if cordless base stations are installed within 10 feet of each other. Ranges are approximate, and are dependent on each
site’s unique characteristics. Feedback may result if the Cordless Handset is within three inches of the ESI desktop phone.
I.12
ESI Communications Servers Hardware Installation Manual
External connections
Port card connections
E2-A12 port card • CS-A12 port card
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
I.13
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Port
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Analog
Analog
ESI Communications Servers Hardware Installation Manual
External connections
E2-A4 port card
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
I.14
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Port
Analog
Analog
Analog
Analog
ESI Communications Servers Hardware Installation Manual
External connections
E2-D12 port card • CS-D12 port card
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
Data-
I.15
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Port
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
ESI Communications Servers Hardware Installation Manual
External connections
E2-612 port card • CS-612 port card
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
Data-
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Port
Digital
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
CO
I.16
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
CO
CO
CO
CO
CO
ESI Communications Servers Hardware Installation Manual
External connections
ESI-6ALC port card • CS-6ALC port card
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
I.17
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Port
CO
CO
CO
CO
CO
CO
ESI Communications Servers Hardware Installation Manual
External connections
E2-684 port card • CS-684 port card
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataTip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
I.18
Port
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Analog
Analog
Analog
Analog
CO
CO
CO
CO
CO
CO
ESI Communications Servers Hardware Installation Manual
External connections
E2-DLC12 port card • CS-DLC12 port card
(to 66 Block)
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
Data-
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Port
Signal
Transmit T
Transmit R
Receive T
Receive R
Cable pair
White-Orange
Orange-White
White-Blue
Blue-White
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
1
RJ48 pinout
1
2
5
4
RJ48 labeled as EIA/TIA 568B (AT&T 258A). If RJ48 is labeled as EIA/TIA 568A, connect the violet-brown pair to the white-green pair at the jack.
I.19
ESI Communications Servers Hardware Installation Manual
External connections
ESI-DLC port card • CS-DLC port card
(to 66 Block)
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Transmit T
Transmit R
Receive T
Receive R
1
Cable pair
White-Orange
Orange-White
White-Blue
Blue-White
RJ48 pinout
1
2
5
4
RJ48 labeled as EIA/TIA 568B (AT&T 258A). If RJ48 is labeled as EIA/TIA 568A, connect the violet-brown pair to the white-green pair at the jack.
I.20
ESI Communications Servers Hardware Installation Manual
External connections
SL-DLC82 port card (for use ONLY in slot 2 on ESI-50)
(to 66 Block)
Term
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1
Wire color
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Signal
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
Data-
RJ11
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Port
Data+
DataData+
Data-
Green
Red
Green
Red
Signal
Transmit T
Transmit R
Receive T
Receive R
Cable pair
White-Orange
Orange-White
White-Blue
Blue-White
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Analog
Analog
1
RJ48 pinout
1
2
5
4
RJ48 labeled as EIA/TIA 568B (AT&T 258A). If RJ48 is labeled as EIA/TIA 568A, connect the violet-brown pair to the white-green pair at the jack.
I.21
ESI Communications Servers Hardware Installation Manual
External connections
482 port card (for use ONLY on ESI-50)
Term
Wire color
Signal
RJ11
1
White-Blue
Data+
Green
2
Blue-White
Data-
Red
3
White-Orange
Data+
Green
4
5
Orange-White
White-Green
DataData+
Red
Green
6
Green-White
Data-
Red
7
White-Brown
Data+
Green
8
Brown-White
Data-
Red
9
10
White-Slate
Slate-White
Data+
Data-
Green
Red
11
Red-Blue
Data+
Green
12
Blue-Red
Data-
Red
13
Red-Orange
Data+
Green
14
15
Orange-Red
Red-Green
DataData+
Red
Green
16
Green-Red
Data-
Red
17
Red-Brown
18
19
Brown-Red
Red-Slate
20
Slate-Red
21
Black-Blue
22
Blue-Black
23
24
Black-Orange
Orange-Black
25
Black-Green
Tip
Green
26
Green-Black
Ring
Red
27
Black-Brown
Tip
Green
28
29
Brown-Black
Black-Slate
Ring
Red
30
Slate-Black
31
Yellow-Blue
32
Blue-Yellow
33
34
Yellow-Orange
Orange-Yellow
35
Yellow-Green
36
Green-Yellow
37
38
Yellow-Brown
Brown-Yellow
39
Yellow-Slate
Tip
Green
40
Slate-Yellow
Ring
Red
41
Violet-Blue
Tip
Green
42
43
Blue-Violet
Violet-Orange
Ring
Tip
Red
Green
44
Orange-Violet
Ring
Red
45
Violet-Green
Tip
Green
46
Green-Violet
Ring
Red
47
48
Violet-Brown
Brown-Violet
49
Violet-Slate
50
Slate-Violet
I.22
Port
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Analog
Analog
CO
CO
CO
CO
ESI Communications Servers Hardware Installation Manual
External connections
Cabinet worksheets
ESI-50 • Base and Expansion Cabinets
Term.
Wire color
Signal
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Expansion Cabinet
Pt. Crd. 3
Pt. Crd. 4
1
482
482
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
Data-
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Dig/Ana
100
Dig/Ana
101
Dig/Ana
102
Dig/Ana
103
Dig/Ana
104
Dig/Ana
105
Dig/Ana
106
Dig/Ana
107
Dig/Ana
110
Dig/Ana
111
Dig/Ana
112
Dig/Ana
113
Dig/Ana
114
Dig/Ana
115
Dig/Ana
116
Dig/Ana
117
Dig/Ana
120
Dig/Ana
121
Dig/Ana
122
Dig/Ana
123
Dig/Ana
124
Dig/Ana
125
Dig/Ana
126
Dig/Ana
127
Dig/Ana
130
Dig/Ana
131
Dig/Ana
132
Dig/Ana
133
Dig/Ana
134
Dig/Ana
135
Dig/Ana
136
Dig/Ana
137
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Green
Red
Green
Red
Ana
108
Ana
109
Ana
118
Ana
119
Ana
128
Ana
129
Ana
138
Ana
139
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
Card type 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Base Cabinet
Pt. Crd. 1
Pt. Crd. 2
RJ11
[Main board]
482/DLC82
CO
CO*
CO*
1
CO*/PRI
TX
1
CO*/PRI
`
RX
Note: Extension numbers shown are valid only if “100” flexible numbering template is in use.
1
*
DLC82 can be installed in only slot 2.
CO lines’ numerical designations vary, depending on whether there is a DLC installed.
I.23
ESI Communications Servers Hardware Installation Manual
External connections
ESI-100 • Base and Expansion Cabinets
Term.
Wire color
Signal
RJ11
Base Cabinet
Pt. Crd. 1
Pt. Crd. 2
Pt. Crd. 3
Expansion Cabinet(s)
Pt. Crd. 4
Pt. Crd. 5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Orange-Yellow
OH Page Audio B
Yellow-Green OH Page Relay Normally Open
Green-Yellow
Relay Common
Yellow-Brown
Brown-Yellow
Relay Normally Closed
Yellow-Slate
Tip
Green
Slate-Yellow
Ring
Red
Violet-Blue
Tip
Green
Blue-Violet
Ring
Red
Violet-Orange
Tip
Green
Orange-Violet
Ring
Red
Violet-Green
Tip
Green
Green-Violet
Ring
Red
Violet-Brown
Tip
Green
Brown-Violet
Ring
Red
Violet-Slate
Tip
Green
Slate-Violet
Ring
Red
Dig/Ana
100
Dig/Ana
101
Dig/Ana
102
Dig/Ana
103
Dig/Ana
104
Dig/Ana
105
Dig/Ana
106
Dig/Ana
107
Dig/Ana
108
Dig/Ana
109
Dig/Ana
110
Dig/Ana
111
Dig/Ana
112
Dig/Ana
113
Dig/Ana
114
Dig/Ana
115
Dig/Ana
116
Dig/Ana
117
Dig/Ana
118
Dig/Ana
119
Dig/Ana
120
Dig/Ana
121
Dig/Ana
122
Dig/Ana
123
Dig/Ana
124
Dig/Ana
125
Dig/Ana
126
Dig/Ana
127
Dig/Ana
128
Dig/Ana
129
Dig/Ana
130
Dig/Ana
131
Dig/Ana
132
Dig/Ana
133
Dig/Ana
134
Dig/Ana
135
Dig/Ana
136
Dig/Ana
137
Dig/Ana
138
Dig/Ana
139
Dig/Ana
140
Dig/Ana
141
Dig/Ana
142
Dig/Ana
143
Dig/Ana
144
Dig/Ana
145
Dig/Ana
146
Dig/Ana
147
OH Page Audio A
Paging controls on second port
card are active only if IVC is
installed in slot 1.
*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO
CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
TX
TX
TX
TX
CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
RX
RX
RX
RX
Note: Extension numbers shown are valid only if “100” flexible numbering template is in use.
*
Slot 6
(Unused)
Card type CO lines’ numerical designations vary, depending on whether there is a DLC installed.
I.24
(For CSASC only)
ESI Communications Servers Hardware Installation Manual
External connections
ESI-200 • Base Cabinet
Term.
Wire color
Signal
RJ11
Pt. Crd. 1
Pt. Crd. 2
Pt. Crd. 3
Pt. Crd. 4
Pt. Crd. 5
Pt. Crd. 6
Pt. Crd. 7
Dig/Ana
100
Dig/Ana
101
Dig/Ana
102
Dig/Ana
103
Dig/Ana
104
Dig/Ana
105
Dig/Ana
106
Dig/Ana
107
Dig/Ana
108
Dig/Ana
109
Dig/Ana
110
Dig/Ana
111
Dig/Ana
112
Dig/Ana
113
Dig/Ana
114
Dig/Ana
115
Dig/Ana
116
Dig/Ana
117
Dig/Ana
118
Dig/Ana
119
Dig/Ana
120
Dig/Ana
121
Dig/Ana
122
Dig/Ana
123
Dig/Ana
124
Dig/Ana
125
Dig/Ana
126
Dig/Ana
127
Dig/Ana
128
Dig/Ana
129
Dig/Ana
130
Dig/Ana
131
Dig/Ana
132
Dig/Ana
133
Dig/Ana
134
Dig/Ana
135
Dig/Ana
136
Dig/Ana
137
Dig/Ana
138
Dig/Ana
139
Dig/Ana
140
Dig/Ana
141
Dig/Ana
142
Dig/Ana
143
Dig/Ana
144
Dig/Ana
145
Dig/Ana
146
Dig/Ana
147
Dig/Ana
148
Dig/Ana
149
Dig/Ana
150
Dig/Ana
151
Dig/Ana
152
Dig/Ana
153
Dig/Ana
154
Dig/Ana
155
Dig/Ana
156
Dig/Ana
157
Dig/Ana
158
Dig/Ana
159
Dig/Ana
160
Dig/Ana
161
Dig/Ana
162
Dig/Ana
163
Dig/Ana
164
Dig/Ana
165
Dig/Ana
166
Dig/Ana
167
Dig/Ana
168
Dig/Ana
169
Dig/Ana
170
Dig/Ana
171
Dig/Ana
172
Dig/Ana
173
Dig/Ana
174
Dig/Ana
175
Dig/Ana
176
Dig/Ana
177
Dig/Ana
178
Dig/Ana
179
Dig/Ana
180
Dig/Ana
181
Dig/Ana
182
Dig/Ana
183
Card type 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
OH Page Audio A
OH Page Audio B
OH Page Relay Normally Open
Relay Common
Paging controls on second port card
are active only if IVC is installed
in slot 1.
Relay Normally Closed
Tip
Green
*
CO
CO*
CO*
CO*
CO*
CO*
CO*
Ring
Red
Tip
Green
CO*
CO*
CO*
CO*
CO*
CO*
CO*
Ring
Red
Tip
Green
CO*
CO*
CO*
CO*
CO*
CO*
CO*
Ring
Red
Tip
Green
CO*
CO*
CO*
CO*
CO*
CO*
CO*
Ring
Red
Tip
Green CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
TX
TX
TX
TX
TX
TX
TX
Ring
Red
Tip
Green CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
RX
RX
RX
RX
RX
RX
RX
Ring
Red
Note: Extension numbers shown are valid only if “100” flexible numbering template is in use.
*
CO lines’ numerical designations vary, depending on whether there is a DLC installed.
I.25
ESI Communications Servers Hardware Installation Manual
External connections
ESI-1000, ESI-600 • Base Cabinet
Term.
Wire color
Signal
RJ11
Pt. Crd. 1
Pt. Crd. 2
Pt. Crd. 3
Pt. Crd. 4
Pt. Crd. 5
Pt. Crd. 6
Pt. Crd. 7
Dig/Ana
100
Dig/Ana
101
Dig/Ana
102
Dig/Ana
103
Dig/Ana
104
Dig/Ana
105
Dig/Ana
106
Dig/Ana
107
Dig/Ana
108
Dig/Ana
109
Dig/Ana
110
Dig/Ana
111
Dig/Ana
112
Dig/Ana
113
Dig/Ana
114
Dig/Ana
115
Dig/Ana
116
Dig/Ana
117
Dig/Ana
118
Dig/Ana
119
Dig/Ana
120
Dig/Ana
121
Dig/Ana
122
Dig/Ana
123
Dig/Ana
124
Dig/Ana
125
Dig/Ana
126
Dig/Ana
127
Dig/Ana
128
Dig/Ana
129
Dig/Ana
130
Dig/Ana
131
Dig/Ana
132
Dig/Ana
133
Dig/Ana
134
Dig/Ana
135
Dig/Ana
136
Dig/Ana
137
Dig/Ana
138
Dig/Ana
139
Dig/Ana
140
Dig/Ana
141
Dig/Ana
142
Dig/Ana
143
Dig/Ana
144
Dig/Ana
145
Dig/Ana
146
Dig/Ana
147
Dig/Ana
148
Dig/Ana
149
Dig/Ana
150
Dig/Ana
151
Dig/Ana
152
Dig/Ana
153
Dig/Ana
154
Dig/Ana
155
Dig/Ana
156
Dig/Ana
157
Dig/Ana
158
Dig/Ana
159
Dig/Ana
160
Dig/Ana
161
Dig/Ana
162
Dig/Ana
163
Dig/Ana
164
Dig/Ana
165
Dig/Ana
166
Dig/Ana
167
Dig/Ana
168
Dig/Ana
169
Dig/Ana
170
Dig/Ana
171
Dig/Ana
172
Dig/Ana
173
Dig/Ana
174
Dig/Ana
175
Dig/Ana
176
Dig/Ana
177
Dig/Ana
178
Dig/Ana
179
Dig/Ana
180
Dig/Ana
181
Dig/Ana
182
Dig/Ana
183
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
Card type 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
TX
TX
TX
TX
TX
TX
TX
CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
RX
RX
RX
RX
RX
Note: Extension numbers shown are valid only if “100” flexible numbering template is in use.
* CO lines’ numerical designations vary, depending on whether there is a DLC installed.
I.26
RX
RX
ESI Communications Servers Hardware Installation Manual
External connections
ESI-1000, ESI-600, ESI-200 • Expansion Cabinet
Term.
Wire color
Signal
RJ11
Pt. Crd. 1
Pt. Crd. 2
Pt. Crd. 3
Pt. Crd. 4
Pt. Crd. 5
Pt. Crd. 6
Pt. Crd. 7
Dig/Ana
184
Dig/Ana
185
Dig/Ana
186
Dig/Ana
187
Dig/Ana
188
Dig/Ana
189
Dig/Ana
190
Dig/Ana
191
Dig/Ana
192
Dig/Ana
193
Dig/Ana
194
Dig/Ana
195
Dig/Ana
196
Dig/Ana
197
Dig/Ana
198
Dig/Ana
199
Dig/Ana
200
Dig/Ana
201
Dig/Ana
202
Dig/Ana
203
Dig/Ana
204
Dig/Ana
205
Dig/Ana
206
Dig/Ana
207
Dig/Ana
208
Dig/Ana
209
Dig/Ana
210
Dig/Ana
211
Dig/Ana
212
Dig/Ana
213
Dig/Ana
214
Dig/Ana
215
Dig/Ana
216
Dig/Ana
217
Dig/Ana
218
Dig/Ana
219
Dig/Ana
220
Dig/Ana
221
Dig/Ana
222
Dig/Ana
223
Dig/Ana
224
Dig/Ana
225
Dig/Ana
226
Dig/Ana
227
Dig/Ana
228
Dig/Ana
229
Dig/Ana
230
Dig/Ana
231
Dig/Ana
232
Dig/Ana
233
Dig/Ana
234
Dig/Ana
235
Dig/Ana
236
Dig/Ana
237
Dig/Ana
238
Dig/Ana
239
Dig/Ana
240
Dig/Ana
241
Dig/Ana
242
Dig/Ana
243
Dig/Ana
244
Dig/Ana
245
Dig/Ana
246
Dig/Ana
247
Dig/Ana
248
Dig/Ana
249
Dig/Ana
250
Dig/Ana
251
Dig/Ana
252
Dig/Ana
253
Dig/Ana
254
Dig/Ana
255
Dig/Ana
256
Dig/Ana
257
Dig/Ana
258
Dig/Ana
259
Dig/Ana
260
Dig/Ana
261
Dig/Ana
262
Dig/Ana
263
Dig/Ana
264
Dig/Ana
265
Dig/Ana
266
Dig/Ana
267
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
CO*
Card type 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
White-Blue
Blue-White
White-Orange
Orange-White
White-Green
Green-White
White-Brown
Brown-White
White-Slate
Slate-White
Red-Blue
Blue-Red
Red-Orange
Orange-Red
Red-Green
Green-Red
Red-Brown
Brown-Red
Red-Slate
Slate-Red
Black-Blue
Blue-Black
Black-Orange
Orange-Black
Black-Green
Green-Black
Black-Brown
Brown-Black
Black-Slate
Slate-Black
Yellow-Blue
Blue-Yellow
Yellow-Orange
Orange-Yellow
Yellow-Green
Green-Yellow
Yellow-Brown
Brown-Yellow
Yellow-Slate
Slate-Yellow
Violet-Blue
Blue-Violet
Violet-Orange
Orange-Violet
Violet-Green
Green-Violet
Violet-Brown
Brown-Violet
Violet-Slate
Slate-Violet
Data+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+
DataData+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Data+/Tip
Data-/Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
Green
Red
CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
TX
TX
TX
TX
TX
TX
TX
CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI CO*/T1/PRI
RX
RX
RX
RX
RX
Note: Extension numbers shown are valid only if “100” flexible numbering template is in use.
* CO lines’ numerical designations vary, depending on whether there is a DLC installed.
I.27
RX
RX
ESI Communications Servers Hardware Installation Manual
Ordering and installing PRI circuits
Ordering and installing PRI circuits
This section addresses considerations to make when ordering and installing ISDN PRI circuits on PRI-ready ESI
Communications Servers [except ESI-50L].
When ordering and provisioning such circuits, you must correctly define certain parameters in order for the PRI
to function correctly. This section is a template for a PRI order form you can use to order PRI circuits that — if
provisioned according to the order form — will be fully compatible with PRI-ready ESI systems.
PRI configuration description
• Agent company — Name of the company that’s ordering the PRI on behalf of the customer.
• Contact — The individual who’s placing the PRI order.
• Address — Address of the agent company.
• Customer name — The name of the end user’s company.
• Circuit ID — The circuit number (or sequence of characters and numbers) that the service provider uses to
identify the PRI circuit. This is used to identify the PRI circuit when troubleshooting or reporting trouble.
• Support phone number — The service provider’s customer service phone number.
• PRI line protocol — The ISDN protocol offered by the service provider. ESI strongly recommends using the
NI-2 (National ISDN-2) protocol.
• Framing and line encoding — You must use ESF (extended super frame) framing and B8ZS (binary eightzero substitution) encoding.
• Pilot/DID numbers — When you order a PRI line, you can separate its 23 channels into one or more “hunt”
groups, each of which has its own main, or pilot, number. A PRI can also support DID (direct inward dialing)
numbers, which typically arew assigned to individual extensions or departments. For example, an ESI-100 can
support up to 10 pilot numbers and up to 300 DID numbers. When you program a pilot number in a PRIcompatible ESI system (by using Installer Function 255), you must enter the maximum number of PRI channels
(one to 23) that can be used for the pilot number hunt group. For example:
Pilot number
Name
Chs.
Day ring 1
2145554378
ABC SYSTEMS
10
Dept. 290
2145552390
ABC SYS SVC
9
Dept. 291
2145555678
ABC SYS INTL
4
X100, X101
Day ring 3
Day ring 5
X100, X101 X102
Dept. 290
Day ring 9
Total pilot number channels: 23
Important: The total number of PRI pilot number channels assigned cannot exceed 23; otherwise, intermittent
problems may result.
• Glare resolution — Must be normal (also called standard); i.e.,. cannot be yielding.
Glare is the condition wherein an outgoing call and an incoming call attempt to seize the same circuit at the
same time. On loop-start analog lines, this usually causes the two callers to be connected, because loop-start
lines do not manage glare resolution. However, PRi trunks utilize a standard glare resolution protocol, which
must be set up correctly on both the service provider’s switch and the ESI system. Part of glare resolution
defines what the CO would do with a call if glare is detected; and the ESi system will block an outgoing call if,
indeed, glare is detected. This frees up the channel so that the service provider’s incoming call rings through.
Because of this, the service provider’s switch must be programmed for normal glare resolution.
• Incoming hunt — Must be ascending.
Another portion of glare resolution requires specifying to the CO in which direction incoming calls should hunt.
To minimize glare, ESI systems perform either an ascending incoming hunt (from channel 1 to channel 23) or
a descending outgoing hunt (from channel 23 to channel 1). When ordering the PRI, you must make the
service provider aware of this requirement.
• ISDN bearer capabilities — This is the supported PRI feature set. Currently, ESI systems support only 56K
voice (CSV). This feature set also supports fax and modem transmissions.
(Continued)
J.1
ESI Communications Servers Hardware Installation Manual
Ordering and installing PRI circuits
• Service termination — ESI recommends that the PRI circuit be terminated on an eight-pin RJ-68 (i.e., “Smart
Jack”). If an RJ-68 isn’t available, you may use an eight-pin RJ-48 jack. If you use an external CSU (channel
service unit), be sure to turn off the CSU in the ESI system.
Important: ESI recommends that, when you connect a cable between the T1/PRI and a CSU or Smart Jack, you
use Category 5 (or better) twisted-pair cable with a length of at least six feet.
• Span type — Use DSX-1 when the cable length to a repeater is less than 655 feet (“short-haul”). [A CSU,
multiplexer, or Smart Jack is considered a repeater.] Use DS-1 for longer distances to a repeater. (See next
item, “Line build-out.”)
• Line build-out (LBO) — Settings to compensate for distance to nearest repeater.
ESI systems support both “short-haul” and “long-haul” (attention settings up to -22.5 dB). Although ESI
systems can support both types of LBO, “short-haul” settings are typically used.
[See next page for sample of order form template. On the ESI Resellers’ site’s tech support page
(www.esi-estech.com/Resellers/tech), you can download a PDF version — listed as Technical Update #176,
from which this section is derived — that can be filled out on a PC using Adobe Reader.]
J.2
ESI Communications Servers Hardware Installation Manual
J.3
Ordering and installing PRI circuits
Index
60-Key Expansion Console, B.4, I.8, I.9
60-Key Second Expansion Console, B.4, I.8, I.9
Access Device, F.16, G.7, H.7
Analog ports, I.7
Auto-Connect, F.16, G.7, H.7
Battery. See Cautions
Cabinets
Expansion, F.2
Cautions, E.1
Battery, E.1
Fuse, E.1
Power supply, E.1
CO lines
Capacities. See System capacities
Connecting, I.5
Console, B.4, I.8, I.9
ESI Cordless Handsets. See Phones
ESI Presence Management, D.1
Expansion Cabinet, F.2
Expansion Console, B.4, I.8, I.9
Fuse. See Cautions
Grounding, F.2, I.1, I.3
Hardware installation, E.2–F.18
LED functions, F.15, G.6, H.6
Main board, A.2
Memory Module, A.3
Installation or replacement, F.5–F.8, G.5, H.5
Mirrored Memory Module (M3), A.3
Installation, F.9–F.13
MOH, I.3
NSP (Network Services Processor), A.7
Overlays, B.4
Paging, I.4
Phones
Digital phones, B.1
ESI Cordless Handsets, B.3
IP phones, B.2
VIP Softphone, B.4
Port cards
Capacities, A.4
Charts, I.13–I.20
Installation, G.3–G.4, G.3–G.4
Installation, F.2
Port card adapter, F.3
Power, I.1
Power Distribution Shelf, A.3
Power supply. See Cautions
Transformers, wall-mount, A.3
PRI, I.5
Regulatory information (U.S. and Canada), E.2
Ringer equivalence number (REN), E.2
Serial ports, I.3
Site location, F.1
SMDR, I.3
System capacities, D.1
T1, I.5
UPS (uninterruptible power supply), I.1
VIP Softphone. See Phones
www.esi-estech.com