Download Mitsubishi Electric PRH-P8MYA Specifications

Transcript
AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS
Series
COOLING ONLY
HEAT PUMP
:PR-5,8,10,15,20
:PRH-5,8,10,15,20
PRH-5,8,10,15,20-L
DATA BOOK
CONTENTS
SAFETY FOR USE -----------------------------------------------------2
A COMPLETE LINE UP -----------------------------------------------4
FEATURES ---------------------------------------------------------------5
DESCRIPTIONS --------------------------------------------------------6
MECHANICAL SPECIFICATIONS----------------------------------6
TYPICAL INSTALLATION EXAMPLE------------------------------7
SPECIFICATIONS ------------------------------------------------------8
ELECTRICAL DATA ----------------------------------------------------9
CAPACITY TABLES---------------------------------------------------10
FAN PERFORMANCE -----------------------------------------------21
NC CURVES------------------------------------------------------------25
OUTLINE DIMENSIONS --------------------------------------------27
WIRING DIAGRAMS -------------------------------------------------29
ELECTRICAL OPERATION FLOW CHARTS ------------------41
REFRIGERANT CYCLE SCHEMATICS-------------------------45
SAFETY & CONTROL DEVICES ---------------------------------48
ACCESSORY AVAILABILITY --------------------------------------48
PHYSICAL DATA ------------------------------------------------------49
INSTALLATION --------------------------------------------------------51
INSTRUCTIONS FOR USE ----------------------------------------54
SPECIFICATION GUIDELINES -----------------------------------57
Specifications subject to change without notice.
-1-
SAFETY FOR USE
Before conducting installation work, please read this ''SAFETY FOR USE'' carefully
for correct installation.
Since the caution items shown here contain important description relative to safety, please
observe them without fail.
Warning
Erroneous handling gives a high possibility to induce serious results such as
death or heavy injury.
Caution
Erroneous handling may induce serious injury depending on the situation.
After reading, please keep it with you together the Instruction Manual, and read it again at the
movement of the unit.
Warning
The unit should not be installed by the user.
If the unit is installed improperly, explosion, water
leakage, electric shock or fire may be result.
Consult your dealer or specialist subcontractor for
repair and movement.
Never repair the unit, remodel or transfer it to
another site by yourself.
If they are performed improperly, water leakage, electric
shock or fire may result. If you need to have the unit
repaired or moved, consult your dealer.
For installation, conduct the work correctly by
following the Installation Manual.
Improper installation may cause a fire, electrical shock
or water leakage.
Use only the specified refrigerant (R-22) to charge
the refrigerant circuit.
Do not mix it with any other refrigerant and do not allow
air to remain in the circuit.
Air enclosed in the circuit can cause high pressure resulting
in a rupture and other hazards.
Install the unit on a spot sufficiently durable against
the unit weight.
Insufficient durability can cause an injury by the falling
down of unit.
After completing installation work, make sure that
refrigerant gas has not leaked.
If refrigerant gas has leaked and exposed to fan heater,
stove, oven and so on, it may generate noxious gases.
All electric work must be performed by licensed
technician, according to local regulations and the
instructions given in this manual.
The units should be powered by dedicated power lines.
Power lines with insufficient capacity or improper
electrical work may result in electric shock or fire.
Take a proper measure to suppress the critical
concentration of refrigerant if leaked when
installing the unit in a small room.
The limit density is made not to be exceeded even if the
refrigerant leaks by any chance.
You are necessary to ventilation measures to prevent
the accident. If the refrigerant leaks, hypoxia accident
may caused.
For the countermeasure to be taken, consult your
dealer.
Use only the specified cables for wiring.
The connections must be made secured without
tension the terminals.
Improper connection or fastening can cause a fire or
electrical shock.
The unit should be installed according to the
instructions in order to minimize the risk of damage
from earthquakes, typhoons or strong winds.
Improper installation work can cause an injury by the
falling down of the unit.
The terminal block cover of unit must be firmly
attached to prevent entry of dust and moisture.
Improper mounting of the cover cause electric shock or
fire.
The unit must be installed on stable, flat surface,
in a place where there is no accumulation of snow,
leaves or rubbish.
The unit should be installed in a location where air
and noise emitted by the unit will not disturb the
neighbors.
If the unit is loosely mounted, it may fall, and cause injury.
Use only optional parts authorised by Mitsubishi
Electric.
If the accessories are installed improperly, water
leakage, electric shock or fire may result.
Ask your dealer or an authorised company to install
them.
-2-
Caution
Refrain from installing the unit in an area where
flammable gas can accumulate around the unit.
If the flammable gas can accumulate around the unit, an
explosion can occur.
When the unit is installed at telecommunication
centers or hospitals, take a proper provision
against noise.
The erroneous operation of air conditioner may be
induced by inverter equipment, independent power
device, medical equipment or communication
equipment.
While the erroneous operation of medical equipment or
communication equipment may caused by the air
conditioner.
For special use as for foods, animals/plants,
precision equipment or art objects, the applicability
should be confirmed beforehand.
As the use for the applications other than that
designed originally may result in the deterioration of the
quality. Consult your dealer in this regard.
Do not use the unit under a special atmosphere.
Installing the unit at the following places may cause a
trouble, a place where much machine oil, salt sonnet,
humidity or dust, spa district, a place full of sulfur gas,
volatile gas, or corrosive gas, a place near high
frequency processing machine.
Thermal insulation of the drain pipes is necessary
prevent dew condensation.
If the drain pipes are not properly insulated,
condensation will result and drip on ceiling, floor or other
possessions.
The drain piping must process by surely,and insulate
the drain piping not to be dewy.
When the room humidity exceeds 80% or when the
drain pipe is clogged, water may drip from the indoor
unit. The outdoor unit produces condensation during the
heating operation.
Make sure to provide drainage around the outdoor unit if
such condensation is likely to cause damage.
Install drain piping according to this Installation
Manual to ensure proper drainage.
Place thermal insulation on the pipes to prevent
condensation.
Improper drain piping may cause water leakage and
damage to furniture or other possessions.
The unit must be properly earth connected.
Do not connect the earth wire to gas pipe, city water
pipe, lightning rod or telephone earth wire.
Improper earth connection may cause electrical shock.
When installing at a watery place, provide an
electric leak breaker.
Failure to mount the electric leak breaker may cause
electrical shock.
Use breaker or fuse with proper capacity.
Make sure that there is a main power switch.
Using a wire or a copper wire instead of proper capacity
of fuse can cause fire or trouble.
Other appliances connected to the same line could cause
an overload.
For the power lines, use standard cables of
sufficient current capacity.
Otherwise, current leakage, overheating or fire may
occur.
When installing the power lines, do not apply
tension to the cables.
The tighten or loosen the connections may cause generate
heat and cause fire.
Arrange the configuration of wiring not to bring up
the panel and terminal cover, and fasten the panel
and terminal cover securely.
The poor mounting of the panel or terminal cover may
cause the heat generation of the terminal connection,
a fire or electrical shock.
Do not wash the unit with water.
If washed with water, electrical shock may be caused.
Do not handle the switch with wet hands.
Otherwise electrical shock can be resulted.
Be very careful on handling the unit.
When carrying in outdoor unit, be sure to support it at
four points.
Carrying in and lifting with 3-point support may make
outdoor unit unstable, resulting in a fall of it.
The unit should not be carried by only one person if it is
more than 20kg.
Some units use PP bands for packing.
Do not use any PP band for delivery purpose.
Do not touch the heat exchanger fins with your bear
hands.
Doing so may cut your hands.
Be sure to safely dispose the packaging materials.
Packaging materials, such as catches and other metal
or wooden parts, may cause stabs or other injuries.
Tear off and discard plastic packing bags so that
children will not play any of them.
If children play with a plastic bag which was not torn off,
it may cause a risk of suffocation.
The base and attachments of the unit should be
periodically checked for looseness, cracks or other
damage.
If such defects are left uncorrected, the unit may fall and
cause personal injury or property damage.
Turn on the main power switch more than 6 hours
before starting operation.
Do not turn the main power switch OFF during seasons
of heavy use, doing so can result In failure.
Do not touch the compressor or refrigerant piping
without wearing glove on your hands.
Touching directly such part can cause a burn or
frostbite as it becomes high or low temperature
according to the refrigerant state.
Do not touch the metal edges inside the unit
without wearing glove on your hands.
Touching directly it may injure your hands.
Do not remove the front panel or the fan guard from
the unit when it is running.
You could be injured if you touch rotating, hot or highvoltage parts.
Do not operate the air conditioner without the air
filter set place.
Dust may accumulate, and cause a failure.
At emergency (if you smell something burning), stop
operation and turn the power source switch off.
Continuing the operation without eliminating the
emergency state may cause a machine trouble, fire, or
electrical shock.
After stopping operation, be sure to wait for five
minutes before turning off the main power switch.
Otherwise, water leakage or unit failure may occur.
-3-
A COMPLETE LINE UP
PR-5YC
PRH-5YA
PRH-5YA-L
(PRH ONLY)
Cooling capacity Heatling capacity
14,000 kcal/h
13,000 kcal/h
55,600 BTU/h
51,600 BTU/h
16.3 kW
15.1 kW
PR-8YC
PRH-8YA
PRH-8YA-L
(PRH ONLY)
Cooling capacity Heatling capacity
20,500 kcal/h
19,800 kcal/h
81,300 BTU/h
78,600 BTU/h
23.8 kW
23 kW
PR-10YC
PRH-10YA
PRH-10YA-L
PR-15YC
PRH-15YA
PRH-15YA-L
Cooling capacity Heatling capacity
25,500 kcal/h
27,500 kcal/h
101,200 BTU/h
109,100 BTU/h
29.7 kW
32 kW
(PRH ONLY)
Cooling capacity Heatling capacity
39,100 kcal/h
39,800 kcal/h
157,900 BTU/h 155,100 BTU/h
45.5 kW
46.3 kW
PR-20YC
PRH-20YA
PRH-20YA-L
(PRH ONLY)
(PRH ONLY)
Cooling capacity Heatling capacity
52,600 kcal/h
52,300 kcal/h
207,500 BTU/h 208,700 BTU/h
61.2 kW
60.8 kW
-4-
FEATURES
Labor Saving Installation
High Sensible Cooling Capacity
Because of the single unit configuration, all
refrigeration work can be omitted. The unit operation
can commence immediately after connection to the
power supply, drain piping, ducting and control
system.
The sensible cooling capacity has been significantly
improved through optimized heat exchanger design.
Comfort Heating
The PRH series are designed to provide effective heating
even when the outside temperature is down to 0˚C. The
PRH-L series are designed to provide effective heating
even when the outside temperature is down to -10˚C.In
addition, the twin circuit models, PRH-15,20YA,
PRH-15,20YA-L are provided with control features that
prevents both refrigeration circuits defrosting at the same
time. This ensures constant comfort conditions during
defrost and varying loads.
Low Ambient Cooling
In applications with relatively high internal loads,
there may be a requirement for all series to operate
on cooling at low ambient conditions. An optional
accessory is available to maintain the refrigeration
circuit in balance at outdoor temperatures as low as
0˚C (PRH only).In case of PR,PRH-L is -5˚C.
Please consult your local Mitsubishi Electric Sales
office for application advice on this accessory.
Highly Efficient Operation
The EER (Energy Efficiency Ratio) on these models is
greatly improved by revised design specifications and by
being manufactured stringently to Mitsubishi Electric
high quality standards.
Flexibility of Supply Air Delivery
All series feature belt driven Supply Air fans enabling
accurate matching of actual airflow rates to the specified
quantities. Accurate commissioning is assisted by the
capability to exchange pulleys and belts if necessary to
achieve the desired air balance.
-5-
Wide Electrical Control Capability
All series may be ordered in either of two control
configurations.
The factory standard is for provision of a 24 volt
terminal block to enable a field wired control of the
contractors choice to be connected.
Alternatively, for models PR-5-10YC,PRH-5-10YA,
PRH-5-10YA-L the intelligent "K" series remote
control system may be ordered. The K control
utilizes a microprocessor and includes liquid crystal
display with touch pad for adjustment of control
parameters.
These options give the flexibility to enable
connection to Building Management Systems,
smoke spill cycles, economy cycles, remote
monitoring etc.
Please consult your local Mitsubishi Electric Sales
office for application advice on these controls.
DESCRIPTIONS
MITSUBISHI ELECTRIC Rooftop Air Conditioners
Series PR,PRH,RPH-L are available in a wide
range of sizes and models to enable the designer
to select the best model for each application.
The complete range has been designed for
outdoor installation, and the units are provided with
the latest technological features to ensure
economical, reliable and comfortable ducted type
air conditioning.
All series units are completely assembled, wired
and strictly tested at the factory. They consist of a
compressors, air-cooled condensers, evaporator
fans, condenser fans and auxiliary and control
equipment, completely packaged in a water-proof
enclosure.
With the development of all series demands for
such features as light weight, compactness,
increased capacity, appropriate static pressure , air
flow control, and having flexibility of inter-facing
energy saving electronic controls Mitsubishi
Electric have met market expectations.
MECHANICAL SPECIFICATIONS
General
Condenser Coils
All units are factory assembled, piped, internally
wired and fully charged with R-22. They are also
tested and checked under a strict quality control
system in the factory. All units are designed for
outdoor rooftop or ground level installation. Exterior
surfaces of all units are phosphatized, zinc-coated
steel with acrylic resin primer and ivory white baked
enamel finish.
Refrigeration Controls
Unnecessary power input due to higher
discharge pressure is avoided by high
performance designs of cross-finned coils.
Condenser coils are made of 9.52mm OD,
0.35mm thick seamless copper tubes
mechanically bonded to 0.12mm thick aluminium
plate fins. Each coil is factory pressure and leak
tested at 3.3MPa.
Evaporator Fans
Refrigeration controls include condenser fan,
evaporator fan and compressor contactor. Each
circuit of the unit has a separate set of refrigeration
controls. PR, PRH,PRH-L-15,20 units have two
independent circuits.
Belt-drive, forward curved, centrifugal type fans
made of galvanized steel are used to deliver an
accurate airflow at low noise level.
Condenser Fan
Compressors
This direct-drive propeller fan is dynamically
balanced, to ensure smooth airflow. A weatherproof three-phase squirrel cage induction motor
is used to drive the condenser fan.
All units have high efficiency type hermetic line
starting compressors. Compressors are equipped
with thermal overload protector, overcurrent relay
and high pressure protection controls. Crankcase
heaters are standard .
Evaporator Coils
Highly efficient cross-finned coils are applied to
provide a larger cooling capacity with low air speed
on the coil. Coils are made of 9.52mm OD and
0.35mm thick seamless copper tubing
mechanically bonded to 0.12mm thick aluminium
fins and are factory leak tested at a pressure of
3.3MPa. They are provided with strainers attached
to the capillary tubes to further ensure a clean
system.
- 6-
TYPICAL INSTALLATION EXAMPLE
PR
PRH
PRH-L
- 7-
SPECIFICATIONS
ITEM
TOTAL COOLING CAPACITY
(GROSS)
SENSIBLE COOLING CAPACITY
(GROSS)
TOTALHEATING CAPACITY
(GROSS)
(PRH-YA,PRH-YA-L ONLY)
CAPACITY STEPS
REFRIGERANT
REFRIGERANT CONTROL
EXTERNAR FINISH
COLOR (MUNSELL NO.)
DIMENSION
NET WEIGHT
COMPRESSOR
MOTOR OUTPUT
INDOOR COIL
FAN
FAN MOTOR
FAN MOTOR OUTPUT
NOMINAL AIR FLOW
EXTERNAL STATIC
PRESSURE
OUTDOOR COIL
FAN
FAN MOTOR
FANMOTOR OUTPUT
NOMINAL AIR FLOW
DRAIN CONNECTION
HEIGHT
WIDTH
DEPTH
kW
BTU/h
kcal/h
kW
BTU/h
kcal/h
kW
BTU/h
kcal/h
%
mm
mm
mm
kg
kW
kW
CMM
CFM
L/S
mmAq
Pa
kW
CMM
CFM
L/S
mm
PR-5YC
PR-8YC
PR-10YC
PR-15YC
PR-20YC
PRH-5YA
PRH-8YA
PRH-10YA PRH-15YA PRH-20YA
PRH-5YA-L PRH-8YA-L PRH-10YA-L PRH-15YA-L PRH-20YA-L
16.3
23.8
29.7
46.3
60.8
55,600
81,300
101,200
157,900
207,500
14,000
20,500
25,500
39,800
52,300
13
19.7
25.3
38.4
50.2
44,400
67,100
86,500
130,900
171,400
11,200
16,900
21,800
33,000
43,200
15.1
23
32
45.5
61.2
51,600
78,600
109,100
155,100
208,700
13,000
19,800
27,500
39,100
52,600
0-100
0-50-100
R22(FACTORY CHARGED)
CAPILLARY TUBE
ACRYLIC RESIN COATING
MUNSELL 5Y8/1
1,000
1,000
1,300
1,200
1,990
1,840
1,600
299
393
413
698
729
HERMETIC LINE START (RECIPROCATING)
2 X 7.5
3.73
5.6
7.5
2 X 5.6
CROSS FIN COIL
CENTRIFUGAL (GALVANIZED STEEL) - BELT DRIVE
THREE PHASE CAGE INDUCTION MOTOR
0.75
1.1
1.5
2.2
3
54
84
100
168
190
1,907
2,967
3,532
5,934
6,711
900
1,400
1,660
2,800
3,160
10
10
10
20
20
100
100
100
200
200
CROSS FIN COIL
PROPELLER - DIRECT DRIVE
THREE PHASE CAGE INDUCTION MOTOR
0.15
0.35
0.35
2 X 0.35
2 X 0.35
95
185
185
2 X 185
2 X 185
3,355
6,534
6,534
2 X 6,534
2 X 6,534
1,583
3,083
3,083
2 X 3,083
2 X 3,083
25.4
HIGH PRESSURE SWITCH,FUSE
PROTECTION DEVICES
OVER CURRENT RELAY (COMP.& INDOOR FAN,OUTDOOR FAN )
INTERNAL THERMOSTAT (COMP. & OUTDOOR FAN )
NOTE
ANTI SHORT-CYCLE TIMER, FREEZE & FROST PROTECTOR
1. NOMINAL COOLING & HEATING CAPACITIES ARE BASED FOLLOWING CONDITIONS.
COOLING : INDOOR:27˚CDB, 19˚C WB ; OUTDOOR:35˚C DB.
HEATING : INDOOR:21˚C DB ; OUTDOOR:7 DB, 6˚C WB.
2. CAPACITIES ARE GROSS CAPACITIES WHICH DO NOT INCLUDE A DEDUCTION FOR EVAPORATOR
FAN MOTOR HEAT.
-8-
ELECTRICAL DATA
Cooling
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
PR-5YC
PRH-5YA
PRH-5YA-L
5.4
10.3
73
62
415V COMPRESSOR INPUT
RUN CURRENT
I/D FAN INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
kW
A
kW
A
kW
A
3.92
7.44
1.24
2.26
0.24
0.6
6.46
11.70
1.30
2.90
0.54
1.3
9.22
15.62
1.64
3.28
0.54
1.3
2 X 6.55
2 X 11.74
2.62
4.72
2 X 0.54
2 X 1.3
2 X 9.30
2 X 15.22
3.02
6.06
2 X 0.54
2 X 1.3
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
5.4
11.2
73
68
8.3
17.3
73
95
11.4
21.9
79
109
16.8
33.6
76
126
22.7
42.6
81
147
380V COMPRESSOR INPUT
RUN CURRENT
I/D FAN INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
kW
A
kW
A
kW
A
3.92
8.06
1.24
2.48
0.24
0.66
6.46
12.71
1.30
3.17
0.54
1.42
9.22
16.90
1.64
3.58
0.54
1.42
2 X 6.55
2 X 12.80
2.62
5.16
2 X 0.54
2 X 1.42
2 X 9.30
2 X 16.57
3.02
6.62
2 X 0.54
2 X 1.42
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
PRH-5YA
PRH-5YA-L
4.8
9.8
68
62
PRH-8YA
PRH-8YA-L
7.0
14.1
69
87
PRH-10YA
PRH-10YA-L
9.6
18.2
73
100
415V COMPRESSOR INPUT
RUN CURRENT
I/D FAN INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
kW
A
kW
A
kW
A
3.32
6.94
1.24
2.26
0.24
0.6
5.16
9.90
1.30
2.90
0.54
1.3
7.42
13.62
1.64
3.28
0.54
1.3
2 X 5.35
2 X 9.94
2.62
4.72
2 X 0.54
2 X 1.3
2 X 7.60
2 X 13.07
3.02
6.06
2 X 0.54
2 X 1.3
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
kW
A
%
A
4.8
10.7
68
68
7.0
15.4
69
95
9.6
20.0
73
109
14.4
29.6
74
121
19.3
38.1
77
143
kW
A
kW
A
kW
A
3.32
7.56
1.24
2.48
0.24
0.66
5.16
10.81
1.30
3.17
0.54
1.42
7.42
15.00
1.64
3.58
0.54
1.42
2 X 5.35
2 X 10.8
2.62
5.16
2 X 0.54
2 X 1.42
2 X 7.60
2 X 14.32
3.02
6.62
2 X 0.54
2 X 1.42
VOLT
ITEM
Heating
VOLT
PR-8YC
PRH-8YA
PRH-8YA-L
8.3
15.9
73
87
PR-10YC
PRH-10YA
PRH-10YA-L
11.4
20.2
79
100
PR-15YC
PRH-15YA
PRH-15YA-L
16.8
30.8
76
115
PR-20YC
PRH-20YA
PRH-20YA-L
22.7
39.1
81
135
(PRH,PRH-L Only)
ITEM
380V COMPRESSOR INPUT
RUN CURRENT
I/D FAN INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
-9-
PRH-15YA
PRH-15YA-L
14.4
27.2
74
111
PRH-20YA
PRH-20YA-L
19.3
34.8
77
131
- 10 -
21.4
24
19.5
21
20.7
19.0
20
23
21.4
24
20.1
20.7
23
22
20.1
22
19.0
19.5
20
21
20.7
18.5
19
20.1
22
23
19.5
21
18.5
19.0
19
20
19.5
17.9
18
19.0
20
21
18.5
17.4
17
19
16.9
16
17.9
18.5
19
18
17.9
16.9
16
18
16.4
15
17.4
17.4
17
17
16.9
16.4
15
16
Q kW
WB ˚C
11.8
12.6
13.7
14.6
15.6
10.1
11.0
11.9
12.9
13.7
14.8
9.1
10.1
10.9
12.0
13.0
14.0
9.2
10.1
11.1
12.2
13.1
14.0
9.4
10.2
11.1
12.2
13.1
9.4
10.3
11.3
SHCkW
20.0
5.0
4.9
4.9
4.8
4.8
5.0
4.9
4.9
4.8
4.8
4.7
4.9
4.9
4.8
4.8
4.7
4.7
4.8
4.8
4.7
4.7
4.6
4.6
4.7
4.7
4.6
4.6
4.5
4.6
4.6
4.5
T/I kW
20.6
19.9
19.3
18.8
18.3
20.6
19.9
19.3
18.8
18.3
17.8
19.9
19.3
18.8
18.3
17.8
17.3
18.8
18.3
17.8
17.3
16.8
16.3
17.8
17.3
16.8
16.3
15.8
16.8
16.3
15.8
Q kW
11.5
12.3
13.3
14.3
15.2
AIR VOLUME
CAPACITY
TOTAL INPUT
PR-5YC
PRH-5YA
PRH-5YA-L
COOLING
9.7
10.5
11.6
12.6
13.4
14.4
8.8
9.7
10.7
11.7
12.6
13.7
8.8
9.7
10.9
11.9
12.8
13.7
9.1
10.0
10.9
11.9
12.8
9.1
10.1
11.1
SHCkW
25.0
0.56
0.62
0.69
0.76
0.83
0.47
0.53
0.60
0.67
0.73
0.81
0.44
0.50
0.57
0.64
0.71
0.79
0.47
0.53
0.61
0.69
0.76
0.84
0.51
0.58
0.65
0.73
0.81
0.54
0.62
0.70
SHF
45
750
0.975
0.987
CMM
L/S
830
0.988
0.994
50
SHC:SENSIBLE HEAT CAPACITY
0.55
0.61
0.68
0.75
0.82
0.47
0.53
0.59
0.66
0.72
0.80
0.44
0.50
0.56
0.63
0.70
0.78
0.47
0.53
0.60
0.68
0.75
0.83
0.51
0.57
0.64
0.72
0.80
0.54
0.61
0.69
SHF
Factor for Various Air Flow
Note1. * Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
19.8
19.1
18.5
18.0
17.6
19.8
19.1
18.5
18.0
17.6
17.1
19.1
18.5
18.0
17.6
17.1
16.6
18.0
17.6
17.1
16.6
16.1
15.6
17.1
16.6
16.1
15.6
15.2
16.1
15.6
15.2
Q kW
11.3
12.0
13.0
14.0
15.0
9.5
10.3
11.3
12.2
13.2
14.2
8.6
9.4
10.4
11.4
12.3
13.4
8.6
9.5
10.6
11.6
12.4
13.4
8.9
9.8
10.6
11.5
12.5
8.9
9.8
10.8
SHCkW
920
1.0
1.0
55
1,000
1.013
1.005
60
T/I:TOTAL INPUT
5.3
5.2
5.1
5.1
5.0
5.3
5.2
5.1
5.1
5.0
4.9
5.2
5.1
5.1
5.0
4.9
4.9
5.1
5.0
4.9
4.9
4.8
4.8
4.9
4.9
4.8
4.8
4.7
4.8
4.8
4.7
T/I kW
30.0
0.57
0.63
0.70
0.78
0.85
0.48
0.54
0.61
0.68
0.75
0.83
0.45
0.51
0.58
0.65
0.72
0.81
0.48
0.54
0.62
0.70
0.77
0.86
0.52
0.59
0.66
0.74
0.82
0.55
0.63
0.71
SHF
5.6
5.5
5.4
5.3
5.2
5.6
5.5
5.4
5.3
5.2
5.2
5.5
5.4
5.3
5.2
5.2
5.1
5.3
5.2
5.2
5.1
5.0
5.0
5.2
5.1
5.0
5.0
4.9
5.0
5.0
4.9
T/I kW
18.9
18.3
17.7
17.3
16.8
18.9
18.3
17.7
17.3
16.8
16.3
18.3
17.7
17.3
16.8
16.3
15.9
17.3
16.8
16.3
15.9
15.4
15.0
16.3
15.9
15.4
15.0
14.5
15.4
15.0
14.5
Q kW
OUTDOOR DB ˚C
PR-5YC
PRH-5YA-L
PRH-5YA
11.0
11.9
12.7
13.8
14.6
9.1
10.1
11.0
11.9
12.8
13.9
8.2
9.2
10.2
11.1
12.1
13.2
8.5
9.2
10.3
11.3
12.2
13.2
8.5
9.4
10.3
11.4
12.2
8.5
9.6
10.4
SHCkW
35.0
0.58
0.65
0.72
0.80
0.87
0.48
0.55
0.62
0.69
0.76
0.85
0.45
0.52
0.59
0.66
0.74
0.83
0.49
0.55
0.63
0.71
0.79
0.88
0.52
0.59
0.67
0.76
0.84
0.55
0.64
0.72
SHF
Cooling Capacity (Nominal Air Flow):PR-5YC, PRH-5YA, PRH-5YA-L
5.9
5.8
5.7
5.6
5.5
5.9
5.8
5.7
5.6
5.5
5.4
5.8
5.7
5.6
5.5
5.4
5.3
5.6
5.5
5.4
5.3
5.3
5.2
5.4
5.3
5.3
5.2
5.1
5.3
5.2
5.1
T/I kW
18.0
17.4
16.9
16.4
16.0
18.0
17.4
16.9
16.4
16.0
15.6
17.4
16.9
16.4
16.0
15.6
15.1
16.4
16.0
15.6
15.1
14.7
14.2
15.6
15.1
14.7
14.2
13.8
14.7
14.2
13.8
Q kW
40.0
10.6
11.7
12.5
13.4
14.2
8.8
9.7
10.6
11.6
12.5
13.6
8.0
9.0
9.8
10.7
11.9
12.8
8.2
9.0
10.0
11.0
11.9
12.8
8.3
9.1
10.1
11.1
11.9
8.2
9.2
10.1
SHCkW
0.59
0.67
0.74
0.82
0.89
0.49
0.56
0.63
0.71
0.78
0.87
0.46
0.53
0.60
0.67
0.76
0.85
0.50
0.56
0.64
0.73
0.81
0.90
0.53
0.60
0.69
0.78
0.86
0.56
0.65
0.73
SHF
6.2
6.1
6.0
5.9
5.8
6.2
6.1
6.0
5.9
5.8
5.7
6.1
6.0
5.9
5.8
5.7
5.6
5.9
5.8
5.7
5.6
5.5
5.5
5.7
5.6
5.5
5.5
5.4
5.5
5.5
5.4
T/I kW
16.8
16.4
15.9
15.4
15.0
16.8
16.4
15.9
15.4
15.0
14.6
16.4
15.9
15.4
15.0
14.6
14.2
15.4
15.0
14.6
14.2
13.7
13.3
14.6
14.2
13.7
13.3
13.0
13.7
13.3
13.0
Q kW
46.0
10.2
11.3
12.1
13.1
14.0
8.4
9.3
10.3
11.2
12.2
13.1
7.5
8.6
9.5
10.4
11.4
12.5
7.9
8.6
9.6
10.7
11.5
12.5
7.9
8.8
9.7
10.6
11.6
7.8
8.9
9.8
SHCkW
SHF
0.61
0.69
0.76
0.85
0.93
0.50
0.57
0.65
0.73
0.81
0.90
0.46
0.54
0.62
0.69
0.78
0.88
0.51
0.57
0.66
0.75
0.84
0.94
0.54
0.62
0.71
0.80
0.89
0.57
0.67
0.75
6.5
6.4
6.3
6.2
6.1
6.5
6.4
6.3
6.2
6.1
6.0
6.4
6.3
6.2
6.1
6.0
5.9
6.2
6.1
6.0
5.9
5.8
5.8
6.0
5.9
5.8
5.8
5.7
5.8
5.8
5.7
T/I kW
CAPACITY TABLES
- 11 -
23.0
23.7
24
21.6
21
23
20.9
20
22.3
23.7
24
22
23.0
23
20.9
20
22.3
20.3
19
22
23.0
23
21.6
22.3
22
21
21.6
20.3
21
19.7
18
19
20.9
14.8
21.6
21
20
9.9
20.9
20
12.6
13.6
14.5
15.3
16.3
10.7
11.7
12.7
13.6
14.6
15.6
9.9
10.9
11.9
12.7
13.8
10.9
12.0
13.0
13.9
20.3
19.1
17
14.8
19.7
18.5
16
10.2
19
20.3
19
11.0
12.0
13.0
13.9
10.1
11.1
12.1
SHCkW
18
19.7
18.5
16
18
18.0
15
19.1
19.1
17
17
18.5
18.0
15
16
Q kW
WB ˚C
-5.0
0.53
0.59
0.65
0.71
0.78
0.45
0.51
0.57
0.63
0.70
0.77
0.43
0.49
0.55
0.61
0.68
0.75
0.46
0.52
0.59
0.66
0.73
0.80
0.50
0.56
0.63
0.70
0.77
0.53
0.60
0.67
SHF
23.5
22.8
22.1
21.5
20.8
23.5
22.8
22.1
21.5
20.8
20.2
22.8
22.1
21.5
20.8
12.5
13.5
12.2
15.3
16.2
10.6
11.6
12.6
13.5
14.6
15.6
9.8
10.8
11.8
12.7
13.7
14.7
19.6
20.2
9.9
10.8
11.9
12.9
13.9
14.7
10.1
11.0
12.0
12.9
13.8
10.1
11.0
12.0
SHCkW
21.5
20.8
20.2
19.6
19.0
18.4
20.2
19.6
19.0
18.4
17.9
19.0
18.4
17.9
Q kW
SHF
0.53
0.59
0.55
0.71
0.78
0.45
0.51
0.57
0.63
0.70
0.77
0.43
0.49
0.55
0.61
0.68
0.75
0.46
0.52
0.59
0.66
0.73
0.80
0.50
0.56
0.63
0.70
0.77
0.53
0.60
0.67
AIR VOLUME
CAPACITY
TOTAL INPUT
PR-5YC
PRH-5YA
PRH-5YA-L
COOLING
4.4
4.4
4.3
4.3
4.2
4.4
4.4
4.3
4.3
4.2
4.2
4.4
4.3
4.3
4.2
4.2
4.1
4.3
4.2
4.2
4.1
4.1
4.0
4.2
4.1
4.1
4.0
4.0
4.1
4.0
4.0
T/I kW
23.2
22.5
21.8
21.2
20.5
23.2
22.5
21.8
21.2
20.5
19.9
22.5
21.8
21.2
20.5
19.9
19.3
21.2
20.5
19.9
19.3
18.7
18.2
19.9
19.3
18.7
18.2
17.7
18.7
18.2
17.7
Q kW
45
750
0.975
0.987
CMM
L/S
830
0.988
0.994
50
SHC:SENSIBLE HEAT CAPACITY
4.4
4.4
4.3
4.3
4.2
4.4
4.4
4.3
4.3
4.2
4.2
4.4
4.3
4.3
4.2
4.2
4.1
4.3
4.2
4.2
4.1
4.1
4.0
4.2
4.1
4.1
4.0
4.0
4.1
4.0
4.0
T/I kW
0.0
Factor for Various Air Flow
Note1. * Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
SHF
0.54
0.60
0.66
0.72
0.79
0.45
0.51
0.58
0.64
0.71
0.78
0.43
0.49
0.55
0.62
0.69
0.76
0.46
0.52
0.59
0.67
0.74
0.81
0.50
0.56
0.63
0.71
0.78
0.53
0.60
0.68
4.5
4.5
4.4
4.4
4.3
4.5
4.5
4.4
4.4
4.3
4.3
4.5
4.4
4.4
4.3
4.3
4.2
4.4
4.3
4.3
4.2
4.2
4.1
4.3
4.2
4.2
4.1
4.1
4.2
4.1
4.1
T/I kW
920
1.0
1.0
55
1,000
1.013
1.005
60
T/I:TOTAL INPUT
12.5
13.5
14.4
15.3
16.2
10.4
11.5
12.6
13.6
14.6
15.5
9.7
10.7
11.7
12.7
13.7
14.7
9.8
10.7
11.7
12.9
13.8
14.7
10.0
10.8
11.8
12.9
13.8
9.9
10.9
12.0
SHCkW
5.0
OUTDOOR DB˚C
PR-5YC
PRH-5YA-L
PRH-5YA
22.7
22.0
21.4
20.8
20.1
22.7
22.0
21.4
20.8
20.1
19.5
22.0
21.4
20.8
20.1
19.5
18.9
20.8
20.1
19.5
18.9
18.3
17.9
19.5
18.9
18.3
17.9
17.4
18.3
17.9
17.4
Q kW
12.3
13.2
14.1
15.2
16.1
10.4
11.4
12.4
13.3
14.3
15.2
9.7
10.7
11.6
12.5
13.5
14.4
9.8
10.7
11.7
12.7
13.5
14.5
9.8
10.8
11.7
12.7
13.6
9.7
10.9
11.8
SHCkW
10.0
0.54
0.60
0.66
0.73
0.80
0.46
0.52
0.58
0.64
0.71
0.78
0.44
0.50
0.56
0.62
0.69
0.76
0.47
0.53
0.60
0.67
0.74
0.81
0.50
0.57
0.64
0.71
0.78
0.53
0.61
0.68
SHF
4.6
4.6
4.5
4.5
4.4
4.6
4.6
4.5
4.5
4.4
4.4
4.6
4.5
4.5
4.4
4.4
4.3
4.5
4.4
4.4
4.3
4.3
4.2
4.4
4.3
4.3
4.2
4.2
4.3
4.2
4.2
T/I kW
22.1
21.4
20.8
20.2
19.6
22.1
21.4
20.8
20.2
19.6
19.1
21.4
20.8
20.2
19.6
19.1
18.5
20.2
19.6
19.1
18.5
17.9
17.4
19.1
18.5
17.9
17.4
16.9
17.9
17.4
16.9
Q kW
15.0
12.2
13.1
13.9
14.9
15.9
10.2
11.1
12.3
13.1
14.1
15.1
9.4
10.4
11.3
12.3
13.4
14.2
9.5
10.4
11.5
12.6
13.4
14.3
9.7
10.5
11.5
12.5
13.4
9.7
10.6
11.7
SHCkW
Cooling Capacity (Nominal Air Flow)
(Use for low ambient temp. parts):PR-5YC, PRH-5YA, PRH-5YA-L
SHF
4.8
4.7
4.7
4.6
4.6
4.8
4.7
4.7
4.6
4.6
4.5
4.7
4.7
4.6
4.6
4.5
4.5
4.6
4.6
4.5
4.5
4.4
4.4
4.5
4.5
4.4
4.4
4.3
4.4
4.4
4.3
T/I kW
8.9
27
15.0
16
14.2
14.2
26
27
4.8
4.8
4.7
4.7
4.6
4.6
4.5
4.5
4.4
4.4
4.3
4.3
4.3
HEATING
PRH-5YA
PRH-5YA-L
CAPACITY
TOTAL INPUT
AIR VOLUME
L/S
CMM
4.1
4.1
4.1
4.0
4.0
4.0
3.9
3.9
3.9
3.8
3.8
3.8
3.8
16.3
16.4
16.5
16.6
16.7
16.8
16.9
17.0
17.1
17.2
17.2
17.3
17.4
Q kW
5.3
5.2
5.2
5.1
5.1
5.0
5.0
4.9
4.9
4.8
4.8
4.7
4.7
T/I kW
10.0
OUTDOOR WB ˚C
PRH-5YA-L
PRH-5YA
10.5
10.5
10.6
10.7
10.7
10.8
10.9
10.9
11.0
11.1
11.1
11.2
11.2
T/I kW
45
750
0.975
1.035
830
0.988
1.018
50
T/I : TOTAL INPUT
T/I kW
5.0
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.7
3.7
3.7
3.7
3.7
* Q : HEATING CAPACITY
14.3
14.4
14.5
14.6
14.7
14.8
14.8
14.9
25
24
23
22
21
20
19
18
14.9
15.1
15
17
Q kW
DB ˚C
INDOOR
OPERATION
RANGE
8.9
9.0
9.1
9.1
9.2
9.2
9.3
9.3
9.4
9.4
26
25
24
23
22
21
20
19
18
17
9.5
16
3.7
Q kW
-5.0
OUTDOOR WB ˚C
PRH-5YA-L
Factor for Various Air Flow
0.55
0.61
0.67
0.74
0.81
0.46
0.52
0.59
0.65
0.72
0.79
0.44
0.50
0.56
0.63
0.70
0.77
0.47
0.53
0.60
0.68
0.75
0.82
0.51
0.57
0.64
0.72
0.79
0.54
0.61
0.69
9.5
15
T/I kW
-10.0
Q kW
DB ˚C
INDOOR
OPERATION
RANGE
920
1.0
1.0
55
18.4
18.6
18.7
18.8
18.9
19.0
19.1
19.2
19.3
19.4
19.4
19.5
19.6
1,000
1.008
0.990
60
5.7
5.6
5.6
5.5
5.5
5.4
5.4
5.3
5.3
5.2
5.2
5.1
5.1
T/I kW
4.4
4.4
4.4
4.3
4.3
4.3
4.2
4.2
4.2
4.1
4.1
4.0
4.0
T/I kW
0.0
15.0
Q kW
12.3
12.3
12.4
12.5
12.5
12.6
12.7
12.7
12.8
12.9
12.9
13.0
13.1
Q kW
PRH-5YA
Heating Capacity
(Nominal Air Flow):PRH-5YA, PRH-5YA-L
- 12 -
0.70
17.5
15.9
14.6
13.1
20.5
18.8
17.2
15.8
14.3
13.1
21.6
20.1
18.6
17.1
15.7
14.4
22.8
21.6
25.0
25.7
26.5
27.3
25.0
25.7
26.5
27.3
28.1
29.0
25.7
26.5
27.3
28.1
29.0
30.0
26.5
27.3
18
19
20
21
18
19
20
21
22
23
19
20
21
22
23
24
20
21
17.1
0.78
18.9
24.2
17
30.0
0.87
20.4
23.5
16
24
0.52
13.4
25.7
19
18.6
0.59
14.8
25.0
18
29.0
0.67
16.2
24.2
17
23
0.75
17.6
23.5
16
20.0
0.84
19.2
22.8
15
28.1
0.55
13.3
24.2
17
22
0.63
14.8
23.5
16
7.6
7.5
7.4
7.3
7.2
7.6
7.5
7.4
7.3
7.2
7.1
7.5
7.4
7.3
7.2
7.1
7.0
7.3
7.2
7.1
7.0
7.0
6.9
7.1
7.0
7.0
6.9
6.9
7.0
6.9
6.9
T/I kW
29.3
28.4
27.5
26.7
25.9
29.3
28.4
27.5
26.7
25.9
25.2
28.4
27.5
26.7
25.9
25.2
24.4
26.7
25.9
25.2
24.4
23.6
22.9
25.2
24.4
23.6
22.9
22.3
23.6
22.9
22.3
Q kW
16.7
18.2
19.8
21.4
22.5
14.1
15.3
16.8
18.4
19.9
21.4
12.8
14.3
15.8
17.1
18.6
20.3
12.8
14.2
15.6
17.3
18.6
20.2
13.1
14.4
15.8
17.4
19.0
13.0
14.4
15.8
SHCkW
AIR VOLUME
CAPACITY
TOTAL INPUT
COOLING
60
1,000
0.940
0.978
CMM
L/S
Factor for Various Air Flow
PR-8YC
PRH-8YA
PRH-8YA-L
25.0
0.57
0.64
0.72
0.80
0.87
0.48
0.54
0.61
0.69
0.77
0.85
0.45
0.52
0.59
0.66
0.74
0.83
0.48
0.55
0.62
0.71
0.79
0.88
0.52
0.59
0.67
0.76
0.85
0.55
0.63
0.71
SHF
1,170
0.963
0.987
70
SHC:SENSIBLE HEAT CAPACITY
0.57
0.64
0.71
0.79
0.86
0.48
0.54
0.61
0.68
0.76
0.84
0.45
0.51
0.58
0.65
0.73
0.82
0.48
0.55
0.62
0.71
16.2
22.8
15
SHF
SHCkW
Q kW
WB ˚C
20.0
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
28.5
27.6
26.7
25.9
25.2
28.5
27.6
26.7
25.9
25.2
24.5
27.6
26.7
25.9
25.2
24.5
23.7
25.9
25.2
24.5
23.7
23.0
22.3
24.5
23.7
23.0
22.3
21.7
23.0
22.3
21.7
Q kW
80
1,330
0.987
0.996
90
1,500
1.010
1.005
1,580
1.022
1.010
95
16.5
17.9
19.5
21.0
22.2
14.0
15.2
16.6
18.1
19.7
21.1
12.7
14.2
15.5
16.9
18.4
19.9
12.7
14.1
15.4
17.1
18.6
19.8
13.0
14.2
15.6
17.2
18.7
12.7
14.3
15.6
SHCkW
T/I:TOTAL INPUT
8.1
7.9
7.8
7.7
7.6
8.1
7.9
7.8
7.7
7.6
7.5
7.9
7.8
7.7
7.6
7.5
7.4
7.7
7.6
7.5
7.4
7.3
7.2
7.5
7.4
7.3
7.2
7.2
7.3
7.2
7.2
T/I kW
30.0
0.58
0.65
0.73
0.81
0.88
0.49
0.55
0.62
0.70
0.78
0.86
0.46
0.53
0.60
0.67
0.75
0.84
0.49
0.56
0.63
0.72
0.81
0.89
0.53
0.60
0.68
0.77
0.86
0.55
0.64
0.72
SHF
8.5
8.4
8.3
8.1
8.0
8.5
8.4
8.3
8.1
8.0
7.9
8.4
8.3
8.1
8.0
7.9
7.8
8.1
8.0
7.9
7.8
7.7
7.6
7.9
7.8
7.7
7.6
7.5
7.7
7.6
7.5
T/I kW
27.7
26.8
26.0
25.2
24.5
27.7
26.8
26.0
25.2
24.5
23.8
26.8
26.0
25.2
24.5
23.8
23.0
25.2
24.5
23.8
23.0
22.3
21.6
23.8
23.0
22.3
21.6
21.0
22.3
21.6
21.0
Q kW
OUTDOOR DB˚C
PR-8YC
PRH-8YA-L
PRH-8YA
16.3
17.7
19.2
20.7
22.1
13.6
15.0
16.4
17.9
19.4
20.7
12.3
13.8
15.4
16.7
18.1
19.6
12.3
13.7
15.2
16.8
18.3
19.7
12.6
14.0
15.4
16.8
18.3
12.5
14.0
15.3
SHCkW
35.0
0.59
0.66
0.74
0.82
0.90
0.49
0.56
0.63
0.71
0.79
0.87
0.46
0.53
0.61
0.68
0.76
0.85
0.49
0.56
0.64
0.73
0.82
0.91
0.53
0.61
0.69
0.78
0.87
0.56
0.65
0.73
SHF
Cooling Capacity (Nominal Air Flow):PR-8YC, PRH-8YA, PRH-8YA-L
9.0
8.8
8.7
8.6
8.4
9.0
8.8
8.7
8.6
8.4
8.3
8.8
8.7
8.6
8.4
8.3
8.2
8.6
8.4
8.3
8.2
8.1
7.9
8.3
8.2
8.1
7.9
7.8
8.1
7.9
7.8
T/I kW
26.8
26.0
25.2
24.4
23.7
26.8
26.0
25.2
24.4
23.7
23.0
26.0
25.2
24.4
23.7
23.0
22.3
24.4
23.7
23.0
22.3
21.6
20.9
23.0
22.3
21.6
20.9
20.3
21.6
20.9
20.3
Q kW
40.0
16.1
17.4
18.9
20.5
21.8
13.1
14.6
16.1
17.6
19.0
20.5
12.2
13.6
15.1
16.4
17.7
19.2
12.2
13.5
15.0
16.7
18.1
19.4
12.4
13.8
15.1
16.5
17.9
12.1
13.8
15.0
SHCkW
0.60
0.67
0.75
0.84
0.92
0.49
0.56
0.64
0.72
0.80
0.89
0.47
0.54
0.62
0.69
0.77
0.86
0.50
0.57
0.65
0.75
0.84
0.93
0.54
0.62
0.70
0.79
0.88
0.56
0.66
0.74
SHF
9.5
9.3
9.2
9.0
8.9
9.5
9.3
9.2
9.0
8.9
8.7
9.3
9.2
9.0
8.9
8.7
8.6
9.0
8.9
8.7
8.6
8.5
8.3
8.7
8.6
8.5
8.3
8.2
8.5
8.3
8.2
T/I kW
25.6
24.9
24.1
23.4
22.7
25.6
24.9
24.1
23.4
22.7
22.0
24.9
24.1
23.4
22.7
22.0
21.3
23.4
22.7
22.0
21.3
20.7
20.1
22.0
21.3
20.7
20.1
19.4
20.7
20.1
19.4
Q kW
46.0
15.6
17.2
18.6
20.1
21.3
12.8
14.2
15.7
17.3
18.6
20.0
11.7
13.0
14.5
15.9
17.4
18.7
11.7
13.2
14.5
16.2
17.6
19.1
11.9
13.4
14.7
16.3
17.5
11.8
13.5
14.7
SHCkW
SHF
0.61
0.69
0.77
0.86
0.94
0.50
0.57
0.65
0.74
0.82
0.91
0.47
0.54
0.62
0.70
0.79
0.88
0.50
0.58
0.66
0.76
0.85
0.95
0.54
0.63
0.71
0.81
0.90
0.57
0.67
0.76
10.0
9.9
9.7
9.6
9.4
10.0
9.9
9.7
9.6
9.4
9.2
9.9
9.7
9.6
9.4
9.2
9.1
9.6
9.4
9.2
9.1
9.0
8.8
9.2
9.1
9.0
8.8
8.7
9.0
8.8
8.7
T/I kW
- 13 -
32.0
24
29.2
21
31.0
28.3
20
23
32.0
24
30.1
31.0
23
22
30.1
28.3
20
22
27.4
19
29.2
31.0
23
21
30.1
22
27.4
19
29.2
26.5
18
28.3
29.2
21
21
28.3
20
20
27.4
25.8
17
19
25.2
16
26.5
27.4
19
18
26.5
25.2
16
18
24.4
15
25.8
25.8
17
17
25.2
24.4
15
16
Q kW
WB ˚C
0.0
17.1
18.7
20.1
21.5
26.6
14.6
16.0
17.2
18.7
20.0
25.1
13.2
14.6
16.1
17.5
18.8
23.4
13.3
14.8
16.2
17.8
19.4
23.3
13.5
15.0
16.4
17.8
20.9
13.6
15.1
SHCkW
-5.0
0.55
0.62
0.69
0.76
0.83
0.47
0.53
0.59
0.66
0.73
0.81
0.44
0.50
0.57
0.64
0.71
0.80
0.47
0.54
0.61
0.69
0.77
0.85
0.51
0.58
0.65
0.73
0.81
0.54
0.62
0.70
SHF
0.0
31.8
6.7
0.55
0.62
0.69
0.76
0.83
0.47
0.53
0.59
0.66
0.73
0.81
0.44
0.50
0.57
0.64
0.71
0.80
0.47
0.54
0.61
0.69
0.77
0.86
0.51
0.58
0.66
0.74
0.82
0.54
0.62
0.70
SHF
COOLING
PR-8YC
PRH-8YA
PRH-8YA-L
CAPACITY
TOTAL INPUT
AIR VOLUME
6.7
6.6
6.5
6.4
6.3
6.7
6.6
6.5
6.4
6.3
6.3
6.6
6.5
6.4
6.3
6.3
6.2
6.4
6.3
6.3
6.2
6.2
6.1
6.3
6.2
6.2
6.1
6.1
6.2
6.1
6.1
T/I kW
31.5
30.5
29.6
28.7
27.9
31.5
30.5
29.6
28.7
27.9
27.1
30.5
29.6
28.7
27.9
27.1
26.2
28.7
27.9
27.1
26.2
25.5
24.8
27.1
26.2
25.5
24.8
24.0
25.5
24.8
24.0
Q kW
L/S
CMM
60
0.940
0.978
1,000
0.963
0.987
1,170
70
0.987
0.996
1,330
80
SHC:SENSIBLE HEAT CAPACITY
16.9
18.5
20.0
21.4
26.4
14.5
15.8
17.1
18.6
19.9
24.9
13.2
14.5
16.1
17.5
18.7
23.2
13.3
14.7
16.1
17.7
19.3
23.5
13.5
14.9
16.5
17.9
21.1
13.5
15.0
SHCkW
30.8
29.9
29.0
28.2
31.8
30.8
29.9
29.0
28.2
27.3
30.8
29.9
29.0
28.2
27.3
26.4
29.0
28.2
27.3
26.4
25.7
25.0
27.3
26.4
25.7
25.0
24.2
25.7
25.0
24.2
Q kW
6.6
6.5
6.4
6.3
6.7
6.6
6.5
6.4
6.3
6.3
6.6
6.5
6.4
6.3
6.3
6.2
6.4
6.3
6.3
6.2
6.2
6.1
6.3
6.2
6.2
6.1
6.1
6.2
6.1
6.1
T/I kW
0.0
Factor for Various Air Flow
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
0.55
0.63
0.70
0.77
0.84
0.47
0.53
0.59
0.67
0.74
0.82
0.44
0.50
0.57
0.64
0.72
0.81
0.47
0.54
0.61
0.69
0.77
0.86
0.51
0.58
0.66
0.74
0.82
0.54
0.62
0.70
SHF
6.8
6.7
6.6
6.5
6.4
6.8
6.7
6.6
6.5
6.4
6.4
6.7
6.6
6.5
6.4
6.4
6.3
6.5
6.4
6.4
6.3
6.3
6.2
6.4
6.3
6.3
6.2
6.2
6.3
6.2
6.2
T/I kW
1.010
1.005
1,500
90
1.022
1.010
1,580
95
T/I:TOTAL INPUT
0.0
16.8
18.6
20.1
21.5
26.5
14.3
15.7
16.9
18.7
20.1
25.0
13.0
14.4
15.9
17.3
18.9
23.2
13.1
14.6
16.0
17.6
19.1
23.3
13.4
14.8
16.4
17.8
20.9
13.4
14.9
SHCkW
5.0
OUTDOOR DB˚C
PR-8YC
PRH-8YA-L
PRH-8YA
31.1
30.1
29.2
28.4
27.6
31.1
30.1
29.2
28.4
27.6
26.8
30.1
29.2
28.4
27.6
26.8
25.9
28.4
27.6
26.8
25.9
25.2
24.4
26.8
25.9
25.2
24.4
23.7
25.2
24.4
23.7
Q kW
0.0
16.9
18.4
19.9
21.3
26.1
14.1
15.5
17.0
18.5
19.8
24.7
12.8
14.5
16.0
17.4
18.6
23.0
13.0
14.5
16.1
17.6
19.0
23.3
13.2
14.9
16.3
17.8
20.9
13.4
14.9
SHCkW
10.0
0.56
0.63
0.70
0.77
0.84
0.47
0.53
0.60
0.67
0.74
0.82
0.44
0.51
0.58
0.65
0.72
0.81
0.47
0.54
0.62
0.70
0.78
0.87
0.51
0.59
0.67
0.75
0.83
0.55
0.63
0.71
SHF
7.0
6.9
6.8
6.7
6.6
7.0
6.9
6.8
6.7
6.6
6.6
6.9
6.8
6.7
6.6
6.6
6.5
6.7
6.6
6.6
6.5
6.5
6.4
6.6
6.5
6.5
6.4
6.4
6.5
6.4
6.4
T/I kW
30.6
29.6
28.7
27.9
27.1
30.6
29.6
28.7
27.9
27.1
26.3
29.6
28.7
27.9
27.1
26.3
25.5
27.9
27.1
26.3
25.5
24.8
24.0
26.3
25.5
24.8
24.0
23.3
24.8
24.0
23.3
Q kW
15.0
0.0
16.6
18.4
19.8
21.1
26.0
14.2
15.5
16.7
18.4
19.7
24.6
12.9
14.2
15.7
17.1
18.6
22.9
13.0
14.5
15.8
17.4
18.7
22.9
13.3
14.6
16.1
17.5
20.8
13.2
14.7
SHCkW
Cooling Capacity (Nominal Air Flow)
(Use for low ambient temp. parts):PR-8YC, PRH-8YA, PRH-8YA-L
7.3
7.2
7.1
7.0
6.9
7.3
7.2
7.1
7.0
6.9
6.8
7.2
7.1
7.0
6.9
6.8
6.7
7.0
6.9
6.8
6.7
6.7
6.6
6.8
6.7
6.7
6.6
6.6
6.7
6.6
6.6
T/I kW
22.8
16
22.0
22.0
26
27
5.5
5.5
5.5
5.5
5.4
5.4
5.4
5.4
5.3
5.3
5.3
5.3
HEATING
PRH-8YA
PRH-8YA-L
CAPACITY
TOTAL INPUT
AIR VOLUME
CMM
L/S
5.9
5.9
5.9
5.8
5.8
5.8
5.7
5.7
5.7
5.6
5.6
5.6
5.6
25.1
25.1
25.2
25.3
25.4
25.5
25.5
25.6
25.7
25.8
25.9
25.9
26.0
Q kW
7.9
7.9
7.8
7.7
7.6
7.6
7.5
7.5
7.4
7.3
7.2
7.2
7.1
T/I kW
10.0
OUTDOOR WB ˚C
PRH-8YA-L
PRH-8YA
16.7
16.7
16.8
16.9
17.0
17.0
17.1
17.2
17.3
17.3
17.4
17.5
17.6
T/I kW
0.970
1.070
60
1,000
0.981
1.050
70
1,170
0.992
1.020
80
1,330
T/I : TOTAL INPUT
7.1
7.1
7.1
7.0
7.0
6.9
6.9
6.8
6.8
6.7
6.6
6.6
6.5
T/I kW
* Q : HEATING CAPACITY
22.1
22.2
22.2
22.3
22.4
22.5
22.6
22.6
25
24
23
22
21
20
19
18
22.7
22.9
15
17
Q kW
14.5
14.5
14.6
14.7
14.7
14.8
14.9
15.0
DB ˚C
INDOOR
OPERATION
RANGE
27
26
25
24
23
22
21
20
5.0
15.1
18
15.1
15.2
17
19
15.3
16
5.3
Q kW
-5.0
OUTDOOR WB ˚C
PRH-8YA-L
Factor for Various Air Flow
0.56
0.64
0.71
0.78
0.85
0.48
0.54
0.60
0.68
0.75
0.83
0.45
0.51
0.58
0.65
0.73
0.82
0.48
0.55
0.62
0.70
0.78
0.87
0.52
0.59
0.67
0.75
0.84
0.55
0.63
0.71
SHF
15.4
15
T/I kW
-10
Q kW
DB ˚C
INDOOR
OPERATION
RANGE
1.003
0.995
90
1,500
28.6
28.6
28.7
28.8
28.9
29.0
29.1
29.1
29.2
29.3
29.4
29.5
29.5
1.008
0.982
95
1,580
8.7
8.7
8.6
8.5
8.4
8.4
8.3
8.2
8.1
8.0
7.9
7.8
7.7
T/I kW
6.5
6.5
6.5
6.4
6.4
6.3
6.3
6.3
6.2
6.2
6.1
6.1
6.1
T/I kW
0.0
15.0
Q kW
19.2
19.2
19.3
19.4
19.5
19.5
19.6
19.7
19.8
19.9
19.9
20.0
20.1
Q kW
PRH-8YA
Heating Capacity
(Nominal Air Flow):PRH-8YA, PRH-8YA-L
- 14 -
38.0
39.2
24
35.7
21
23
34.6
20
36.8
39.2
24
22
38.0
23
34.6
20
36.8
33.5
19
35.7
38.0
23
22
36.8
21
35.7
33.5
19
22
32.4
18
21
35.7
21
34.6
34.6
20
20
33.5
31.4
17
32.4
30.4
16
19
33.5
18
32.4
19
30.4
16
18
29.4
15
31.4
31.4
17
17
30.4
29.4
15
16
Q kW
WB ˚C
22.3
24.3
26.1
28.2
30.1
18.8
20.5
22.4
24.6
26.3
28.1
17.1
18.8
20.7
22.8
24.8
26.9
17.1
19.0
21.1
23.3
25.1
26.8
17.4
19.4
21.4
23.1
24.7
17.6
19.5
21.2
SHCkW
20.0
10.6
10.4
10.3
10.1
10.0
10.6
10.4
10.3
10.1
10.0
9.9
10.4
10.3
10.1
10.0
9.9
9.8
10.1
10.0
9.9
9.8
9.7
9.6
9.9
9.8
9.7
9.6
9.5
9.7
9.6
9.5
T/I kW
37.7
36.6
35.4
34.4
33.4
37.7
36.6
35.4
34.4
33.4
32.3
36.6
35.4
34.4
33.4
32.3
31.3
34.4
33.4
32.3
31.3
30.3
29.4
32.3
31.3
30.3
29.4
28.4
30.3
29.4
28.4
Q kW
AIR VOLUME
CAPACITY
TOTAL INPUT
PR-10YC
PRH-10YA
PRH-10YA-L
COOLING
21.9
23.8
25.5
27.9
29.7
18.1
20.1
21.9
24.1
25.7
27.5
16.5
18.1
20.0
22.4
24.2
26.3
16.5
18.4
20.7
22.8
24.5
26.5
16.8
18.8
20.6
22.6
24.1
17.0
18.8
20.7
SHCkW
25.0
0.58
0.65
0.72
0.81
0.89
0.48
0.55
0.62
0.70
0.77
0.85
0.45
0.51
0.58
0.67
0.75
0.84
0.48
0.55
0.64
0.73
0.81
0.90
0.52
0.60
0.68
0.77
0.85
0.56
0.64
0.73
SHF
90
1,500
0.987
0.995
CMM
L/S
1,660
1.0
1.0
100
SHC:SENSIBLE HEAT CAPACITY
0.57
0.64
0.71
0.79
0.87
0.48
0.54
0.61
0.69
0.76
0.84
0.45
0.51
0.58
0.66
0.74
0.83
0.48
0.55
0.63
0.72
0.80
0.88
0.52
0.60
0.68
0.76
0.84
0.56
0.64
0.72
SHF
Factor for Various Air Flow
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
36.1
35.1
34.0
33.0
32.1
36.1
35.1
34.0
33.0
32.1
31.0
35.1
34.0
33.0
32.1
31.0
30.0
33.0
32.1
31.0
30.0
29.1
28.2
31.0
30.0
29.1
28.2
27.3
29.1
28.2
27.3
Q kW
110
1,830
1.033
1.026
120
2,000
1.066
1.052
21.3
23.5
25.2
27.4
29.2
17.7
19.7
21.4
23.4
25.4
27.0
16.1
17.7
19.5
21.8
23.6
25.8
16.2
18.0
20.2
22.2
23.9
25.9
16.4
18.3
20.1
22.0
23.8
16.6
18.3
20.2
SHCkW
T/I:TOTAL INPUT
11.2
11.0
10.8
10.6
10.5
11.2
11.0
10.8
10.6
10.5
10.3
11.0
10.8
10.6
10.5
10.3
10.2
10.6
10.5
10.3
10.2
10.1
9.9
10.3
10.2
10.1
9.9
9.8
10.1
9.9
9.8
T/I kW
30.0
0.59
0.67
0.74
0.83
0.91
0.49
0.56
0.63
0.71
0.79
0.87
0.46
0.52
0.59
0.68
0.76
0.86
0.49
0.56
0.65
0.74
0.82
0.92
0.53
0.61
0.69
0.78
0.87
0.57
0.65
0.74
SHF
11.8
11.6
11.4
11.2
11.0
11.8
11.6
11.4
11.2
11.0
10.9
11.6
11.4
11.2
11.0
10.9
10.7
11.2
11.0
10.9
10.7
10.5
10.4
10.9
10.7
10.5
10.4
10.2
10.5
10.4
10.2
T/I kW
34.5
33.5
32.5
31.6
30.6
34.5
33.5
32.5
31.6
30.6
29.7
33.5
32.5
31.6
30.6
29.7
28.7
31.6
30.6
29.7
28.7
27.9
27.0
29.7
28.7
27.9
27.0
26.1
27.9
27.0
26.1
Q kW
OUTDOOR DB˚C
PR-10YC
PRH-10YA-L
PRH-10YA
20.7
22.8
24.7
26.9
28.5
17.3
19.1
21.1
23.1
24.8
26.4
15.4
17.2
19.0
21.1
23.2
25.3
15.8
17.4
19.6
21.5
23.2
25.4
16.0
17.8
19.5
21.6
23.2
15.9
17.8
19.6
SHCkW
35.0
0.60
0.68
0.76
0.85
0.93
0.50
0.57
0.65
0.73
0.81
0.89
0.46
0.53
0.60
0.69
0.78
0.88
0.50
0.57
0.66
0.75
0.83
0.94
0.54
0.62
0.70
0.80
0.89
0.57
0.66
0.75
SHF
12.4
12.2
12.0
11.8
11.6
12.4
12.2
12.0
11.8
11.6
11.4
12.2
12.0
11.8
11.6
11.4
11.2
11.8
11.6
11.4
11.2
11.0
10.8
11.4
11.2
11.0
10.8
10.7
11.0
10.8
10.7
T/I kW
Cooling Capacity (Nominal Air Flow):PR-10YC, PRH-10YA, PRH-10YA-L
32.9
31.9
31.0
30.1
29.2
32.9
31.9
31.0
30.1
29.2
28.3
31.9
31.0
30.1
29.2
28.3
27.4
30.1
29.2
28.3
27.4
26.6
25.7
28.3
27.4
26.6
25.7
24.4
26.6
25.7
24.4
Q kW
40.0
20.1
22.3
24.2
26.2
28.0
16.8
18.5
20.5
22.6
24.2
25.8
15.0
16.7
18.4
20.4
22.6
24.7
15.4
16.9
19.0
21.1
22.6
24.7
15.6
17.3
18.9
21.1
22.2
15.4
17.2
18.5
SHCkW
0.61
0.70
0.78
0.87
0.96
0.51
0.58
0.66
0.75
0.83
0.91
0.47
0.54
0.61
0.70
0.80
0.90
0.51
0.58
0.67
0.77
0.85
0.96
0.55
0.63
0.71
0.82
0.91
0.58
0.67
0.76
SHF
13.1
12.8
12.6
12.4
12.2
13.1
12.8
12.6
12.4
12.2
12.0
12.8
12.6
12.4
12.2
12.0
11.8
12.4
12.2
12.0
11.8
11.6
11.4
12.0
11.8
11.6
11.4
11.2
11.6
11.4
11.2
T/I kW
30.8
30.0
29.1
28.3
27.4
30.8
30.0
29.1
28.3
27.4
26.6
30.0
29.1
28.3
27.4
26.6
25.7
28.3
27.4
26.6
25.7
24.9
24.1
26.6
25.7
24.9
24.1
23.3
24.9
24.1
23.3
Q kW
46.0
19.7
21.6
23.3
25.8
27.1
16.0
18.0
19.8
21.8
23.6
25.3
14.4
16.3
18.1
20.0
21.8
23.9
14.7
16.4
18.4
20.3
22.2
24.1
14.9
16.7
18.4
20.5
22.1
14.7
16.6
18.4
SHCkW
SHF
0.64
0.72
0.80
0.91
0.99
0.52
0.60
0.68
0.77
0.86
0.95
0.48
0.56
0.64
0.73
0.82
0.93
0.52
0.60
0.69
0.79
0.89
1.00
0.56
0.65
0.74
0.85
0.95
0.59
0.69
0.79
13.9
13.6
13.3
13.1
12.9
13.9
13.6
13.3
13.1
12.9
12.7
13.6
13.3
13.1
12.9
12.7
12.5
13.1
12.9
12.7
12.5
12.3
12.1
12.7
12.5
12.3
12.1
11.9
12.3
12.1
11.9
T/I kW
- 15 -
42.1
43.4
39.4
21
24
38.1
20
23
43.4
24
40.7
42.1
23
22
40.7
38.1
20
22
36.8
19
39.4
42.1
23
21
40.7
22
36.8
19
39.4
35.7
18
21
39.4
21
38.1
38.1
20
20
36.8
34.7
17
19
33.6
16
35.7
36.8
19
18
35.7
33.6
16
18
32.7
15
34.7
34.7
17
17
33.6
32.7
15
16
Q kW
WB ˚C
23.9
25.7
27.7
29.6
31.2
20.0
21.9
24.0
26.0
27.8
29.8
18.5
20.4
22.1
24.0
26.1
28.2
18.5
20.6
22.4
24.6
26.4
28.6
18.8
20.7
22.6
24.5
26.5
18.7
20.8
22.6
SHCkW
-5.0
0.55
0.61
0.68
0.75
0.82
0.46
0.52
0.59
0.66
0.73
0.81
0.44
0.50
0.56
0.63
0.71
0.79
0.47
0.54
0.61
0.69
0.76
0.85
0.51
0.58
0.65
0.73
0.81
0.54
0.62
0.69
SHF
43.1
41.8
40.4
39.1
37.8
43.1
41.8
40.4
39.1
37.8
36.5
41.8
40.4
39.1
37.8
36.5
35.3
39.1
37.8
36.5
35.3
34.3
33.2
36.5
35.3
34.3
33.2
32.3
34.3
33.2
32.3
Q kW
23.7
25.5
27.5
29.3
31.4
19.8
21.7
23.8
25.8
27.6
29.6
18.4
20.2
22.3
24.2
25.9
27.9
18.4
20.4
22.3
24.4
26.1
28.6
18.6
20.5
22.6
24.6
26.5
18.5
20.6
22.3
SHCkW
SHF
0.55
0.61
0.68
0.75
0.83
0.46
0.52
0.59
0.66
0.73
0.81
0.44
0.50
0.57
0.64
0.71
0.79
0.47
0.54
0.61
0.69
0.76
0.86
0.51
0.58
0.66
0.74
0.82
0.54
0.62
0.69
AIR VOLUME
CAPACITY
TOTAL INPUT
PR-10YC
PRH-10YA-L
PRH-10YA
COOLING
9.4
9.3
9.2
9.1
9.0
9.4
9.3
9.2
9.1
9.0
8.9
9.3
9.2
9.1
9.0
8.9
8.8
9.1
9.0
8.9
8.8
8.7
8.6
8.9
8.8
8.7
8.6
8.6
8.7
8.6
8.6
T/I kW
CMM
L/S
90
1,500
0.987
0.995
100
1,660
1.0
1.0
SHF
0.56
0.62
0.69
0.76
0.84
0.47
0.53
0.60
0.67
0.74
0.82
0.44
0.50
0.57
0.64
0.72
0.80
0.47
0.54
0.62
0.70
0.77
0.86
0.51
0.58
0.66
0.74
0.82
0.54
0.62
0.70
9.6
9.5
9.4
9.2
9.1
9.6
9.5
9.4
9.2
9.1
9.0
9.5
9.4
9.2
9.1
9.0
8.9
9.2
9.1
9.0
8.9
8.8
8.7
9.0
8.9
8.8
8.7
8.7
8.8
8.7
8.7
T/I kW
120
2,000
1.066
1.052
T/I:TOTAL INPUT
23.8
25.5
27.5
29.3
31.3
20.0
21.8
23.9
25.9
27.6
29.5
18.1
19.9
22.0
23.9
25.9
27.8
18.1
20.1
22.3
24.4
26.0
28.1
18.4
20.2
22.3
24.2
26.1
18.3
20.3
22.3
SHCkW
5.0
OUTDOOR DB˚C
PR-10YC
PRH-10YA-L
PRH-10YA
110
1,830
1.033
1.026
42.5
41.2
39.8
38.6
37.3
42.5
41.2
39.8
38.6
37.3
36.0
41.2
39.8
38.6
37.3
36.0
34.8
38.6
37.3
36.0
34.8
33.8
32.7
36.0
34.8
33.8
32.7
31.8
33.8
32.7
31.8
Q kW
SHC:SENSIBLE HEAT CAPACITY
9.4
9.3
9.2
9.1
9.0
9.4
9.3
9.2
9.1
9.0
8.9
9.3
9.2
9.1
9.0
8.9
8.8
9.1
9.0
8.9
8.8
8.7
8.6
8.9
8.8
8.7
8.6
8.6
8.7
8.6
8.6
T/I kW
0.0
Factor for Various Air Flow
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
41.6
40.4
39.1
37.8
36.6
41.6
40.4
39.1
37.8
36.6
35.3
40.4
39.1
37.8
36.6
35.3
34.2
37.8
36.6
35.3
34.2
33.2
32.2
35.3
34.2
33.2
32.2
31.2
33.2
32.2
31.2
Q kW
23.3
25.0
27.0
29.1
31.1
19.6
21.4
23.5
25.3
27.1
28.9
17.8
19.9
21.9
23.8
25.4
27.4
17.8
19.8
21.9
23.9
25.9
28.0
18.0
20.2
22.2
24.2
25.9
18.3
20.3
22.2
SHCkW
10.0
SHF
0.56
0.62
0.69
0.77
0.85
0.47
0.53
0.60
0.67
0.74
0.82
0.44
0.51
0.58
0.65
0.72
0.80
0.47
0.54
0.62
0.70
0.78
0.87
0.51
0.59
0.67
0.75
0.83
0.55
0.63
0.71
9.8
9.7
9.6
9.4
9.3
9.8
9.7
9.6
9.4
9.3
9.2
9.7
9.6
9.4
9.3
9.2
9.1
9.4
9.3
9.2
9.1
9.0
8.9
9.2
9.1
9.0
8.9
8.9
9.0
8.9
8.9
T/I kW
40.5
39.3
38.1
36.8
35.7
40.5
39.3
38.1
36.8
35.7
34.5
39.3
38.1
36.8
35.7
34.5
33.4
36.8
35.7
34.5
33.4
32.4
31.4
34.5
33.4
32.4
31.4
30.4
32.4
31.4
30.4
Q kW
23.1
24.8
26.7
28.7
30.7
19.0
21.2
23.2
25.0
26.8
28.6
17.7
19.4
21.3
23.2
25.2
27.1
17.7
19.6
21.7
23.7
25.6
27.6
17.9
19.7
21.7
23.6
25.2
17.8
19.8
21.9
SHCkW
15.0
10.2
10.0
9.9
9.7
9.6
10.2
10.0
9.9
9.7
9.6
9.5
10.0
9.9
9.7
9.6
9.5
9.4
9.7
9.6
9.5
9.4
9.3
9.2
9.5
9.4
9.3
9.2
9.1
9.3
9.2
9.1
T/I kW
21.3
17
30.7
30.6
30.5
25
26
27
9.9
9.8
9.8
9.7
9.6
9.5
9.5
9.4
9.3
9.2
9.2
9.1
9.0
HEATING
PRH-10YA
PRH-10YA-L
CAPACITY
TOTAL INPUT
AIR VOLUME
CMM
L/S
8.4
8.4
8.4
8.3
8.3
8.2
8.2
8.1
8.1
8.0
8.0
7.9
7.9
T/I kW
34.8
35.0
35.1
35.2
35.3
35.5
35.7
35.8
35.9
36.1
36.2
36.4
36.5
Q kW
10.8
10.7
10.7
10.6
10.5
10.4
10.3
10.2
10.1
10.0
10.0
9.9
9.8
T/I kW
10.0
OUTDOOR WB ˚C
PRH-10YA-L
PRH-10YA
23.4
23.5
23.5
23.7
23.8
23.9
24.0
24.1
24.2
24.3
24.4
24.5
24.6
Q kW
-5.0
OUTDOOR WB ˚C
PRH-10YA-L
90
1,500
0.992
1.016
100
1,660
1.0
1.0
T/I : TOTAL INPUT
T/I kW
5.0
7.9
7.9
7.9
7.9
7.8
7.8
7.8
7.7
7.7
7.7
7.6
7.6
7.6
* Q : HEATING CAPACITY
30.8
30.9
31.1
31.2
31.3
31.4
31.6
31.7
24
23
22
21
20
19
18
17
31.8
31.9
15
16
Q kW
20.4
20.5
20.5
20.6
20.7
20.8
20.9
21.0
21.1
DB ˚C
INDOOR
OPERATION
RANGE
27
26
25
24
23
22
21
20
19
21.2
21.4
16
18
21.5
15
T/I kW
-10.0
Q kW
DB ˚C
INDOOR
OPERATION
RANGE
110
1,830
1.025
0.971
39.1
39.3
39.4
39.6
39.7
39.9
40.1
40.2
40.4
40.6
40.7
40.9
41.1
120
2,000
1.050
0.942
11.7
11.6
11.5
11.4
11.3
11.2
11.1
11.0
10.9
10.8
10.7
10.6
10.5
T/I kW
9.1
9.1
9.0
9.0
8.9
8.9
8.8
8.7
8.7
8.6
8.5
8.5
8.4
T/I kW
0.0
15.0
Q kW
26.8
26.9
26.9
27.1
27.2
27.3
27.4
27.5
27.6
27.7
27.8
27.9
28.0
Q kW
PRH-10YA
Heating Capacity
(Nominal Air Flow):PRH-10YA, PRH-10YA-L
Factor for Various Air Flow
0.57
0.63
0.70
0.78
0.86
0.47
0.54
0.61
0.68
0.75
0.83
0.45
0.51
0.58
0.65
0.73
0.81
0.48
0.55
0.63
0.71
0.79
0.88
0.52
0.59
0.67
0.75
0.83
0.55
0.63
0.72
SHF
Cooling Capacity (Nominal Air Flow)
(Use for low ambient temp. parts):PR-10YC, PRH-10YA, PRH-10YA-L
- 16 -
59.0
24
53.9
21
57.3
52.1
20
23
59.0
24
55.7
57.3
23
22
55.7
52.1
20
22
50.5
19
53.9
57.3
23
21
55.7
22
50.5
19
53.9
48.9
18
21
53.9
21
52.1
52.1
20
20
50.5
47.2
17
19
45.7
16
48.9
50.5
19
18
48.9
45.7
16
18
44.5
15
47.2
47.2
17
17
45.7
44.5
15
16
Q kW
WB ˚C
33.6
37.2
40.7
43.1
45.8
28.3
31.5
34.5
37.2
40.1
43.4
25.8
29.0
31.8
34.4
37.4
40.6
26.4
28.7
31.8
34.7
37.3
40.2
26.3
28.9
31.6
34.7
37.8
26.0
29.2
32.0
SHCkW
20.0
15.3
15.1
15.0
14.8
14.6
15.3
15.1
15.0
14.8
14.6
14.5
15.1
15.0
14.8
14.6
14.5
14.3
14.8
14.6
14.5
14.3
14.1
14.0
14.5
14.3
14.1
14.0
13.9
14.1
14.0
13.9
T/I kW
57.4
55.7
54.0
52.3
50.7
57.4
55.7
54.0
52.3
50.7
49.2
55.7
54.0
52.3
50.7
49.2
47.6
52.3
50.7
49.2
47.6
46.0
44.5
49.2
47.6
46.0
44.5
43.3
46.0
44.5
43.3
Q kW
32.7
36.2
39.4
42.4
45.1
28.1
31.2
34.0
36.6
39.5
42.8
25.1
28.1
30.9
33.5
36.9
40.0
25.6
27.9
31.0
34.3
36.8
39.6
25.6
28.1
31.3
34.3
37.2
25.3
28.5
31.2
SHCkW
COOLING
PR-15YC
PRH-15YA
PRH-15YA-L
CAPACITY
TOTAL INPUT
AIR VOLUME
25.0
120
2,000
0.944
0.980
CMM
L/S
130
2,170
0.955
0.984
140
2,330
0.966
0.988
150
2,500
0.978
0.992
2,670
0.981
0.996
160
0.57
0.65
0.73
0.81
0.89
0.49
0.56
0.63
0.70
0.78
0.87
0.45
0.52
0.59
0.66
0.75
0.84
0.49
0.55
0.63
0.72
0.80
0.89
0.52
0.59
0.68
0.77
0.86
0.55
0.64
0.72
SHF
SHC:SENSIBLE HEAT CAPACITY
0.57
0.65
0.73
0.80
0.88
0.48
0.55
0.62
0.69
0.77
0.86
0.45
0.52
0.59
0.66
0.74
0.83
0.49
0.55
0.63
0.71
0.79
0.88
0.52
0.59
0.67
0.76
0.85
0.55
0.64
0.72
SHF
Factor for Various Air Flow
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
55.6
54.0
52.4
50.8
49.3
55.6
54.0
52.4
50.8
49.3
47.8
54.0
52.4
50.8
49.3
47.8
46.2
50.8
49.3
47.8
46.2
44.7
43.2
47.8
46.2
44.7
43.2
42.0
44.7
43.2
42.0
Q kW
170
2,830
1.0
1.0
180
3,000
1.011
1.005
32.2
35.6
38.8
41.7
44.4
27.2
30.2
33.5
36.1
38.9
42.1
24.3
27.8
30.5
33.0
36.3
39.7
25.4
27.6
30.6
33.7
36.2
39.3
25.3
27.7
30.8
33.7
36.5
25.0
28.1
30.7
SHCkW
T/I:TOTAL INPUT
16.2
16.0
15.8
15.6
15.4
16.2
16.0
15.8
15.6
15.4
15.2
16.0
15.8
15.6
15.4
15.2
15.0
15.6
15.4
15.2
15.0
14.9
14.7
15.2
15.0
14.9
14.7
14.5
14.9
14.7
14.5
T/I kW
30.0
0.58
0.66
0.74
0.82
0.90
0.49
0.56
0.64
0.71
0.79
0.88
0.45
0.53
0.60
0.67
0.76
0.86
0.50
0.56
0.64
0.73
0.81
0.91
0.53
0.60
0.69
0.78
0.87
0.56
0.65
0.73
SHF
17.1
16.8
16.6
16.4
16.2
17.1
16.8
16.6
16.4
16.2
16.0
16.8
16.6
16.4
16.2
16.0
15.8
16.4
16.2
16.0
15.8
15.6
15.4
16.0
15.8
15.6
15.4
15.2
15.6
15.4
15.2
T/I kW
53.9
52.3
50.7
49.2
47.7
53.9
52.3
50.7
49.2
47.7
46.3
52.3
50.7
49.2
47.7
46.3
44.8
49.2
47.7
46.3
44.8
43.3
42.0
46.3
44.8
43.3
42.0
40.8
43.3
42.0
40.8
Q kW
OUTDOOR DB˚C
PR-15YC
PRH-15YA-L
PRH-15YA
31.8
35.0
38.0
41.3
43.9
27.0
29.8
32.4
35.4
38.2
41.2
24.1
26.9
30.0
32.4
35.7
39.0
24.6
27.2
30.1
33.2
35.9
39.1
24.5
27.3
30.3
33.2
35.9
24.7
27.7
30.2
SHCkW
35.0
0.59
0.67
0.75
0.84
0.92
0.50
0.57
0.64
0.72
0.80
0.89
0.46
0.53
0.61
0.68
0.77
0.87
0.50
0.57
0.65
0.74
0.83
0.93
0.53
0.61
0.70
0.79
0.88
0.57
0.66
0.74
SHF
18.0
17.7
17.5
17.2
17.0
18.0
17.7
17.5
17.2
17.0
16.8
17.7
17.5
17.2
17.0
16.8
16.6
17.2
17.0
16.8
16.6
16.3
16.1
16.8
16.6
16.3
16.1
15.9
16.3
16.1
15.9
T/I kW
Cooling Capacity (Nominal Air Flow):PR-15YC, PRH-15YA, PRH-15YA-L
52.0
50.5
49.0
47.6
46.1
52.0
50.5
49.0
47.6
46.1
44.7
50.5
49.0
47.6
46.1
44.7
43.2
47.6
46.1
44.7
43.2
41.9
40.7
44.7
43.2
41.9
40.7
39.5
41.9
40.7
39.5
Q kW
40.0
31.2
34.3
37.2
40.9
43.3
26.0
28.8
31.9
34.7
37.3
40.7
23.2
26.5
29.5
31.8
34.9
38.4
24.3
26.7
29.5
32.4
35.6
38.7
24.1
26.8
29.7
32.6
35.2
23.9
27.3
29.6
SHCkW
0.60
0.68
0.76
0.86
0.94
0.50
0.57
0.65
0.73
0.81
0.91
0.46
0.54
0.62
0.69
0.78
0.89
0.51
0.58
0.66
0.75
0.85
0.95
0.54
0.62
0.71
0.80
0.89
0.57
0.67
0.75
SHF
18.9
18.6
18.4
18.2
17.9
18.9
18.6
18.4
18.2
17.9
17.7
18.6
18.4
18.2
17.9
17.7
17.4
18.2
17.9
17.7
17.4
17.1
16.9
17.7
17.4
17.1
16.9
16.6
17.1
16.9
16.6
T/I kW
49.8
48.4
47.0
45.5
44.1
49.8
48.4
47.0
45.5
44.1
42.6
48.4
47.0
45.5
44.1
42.6
41.2
45.5
44.1
42.6
41.2
40.1
39.0
42.6
41.2
40.1
39.0
37.8
40.1
39.0
37.8
Q kW
46.0
30.9
33.9
36.7
40.0
41.9
25.4
28.1
31.0
34.1
36.6
39.6
22.7
25.9
28.7
31.3
34.1
37.1
23.2
26.0
28.5
31.7
34.9
37.8
23.4
26.0
28.9
32.0
34.4
23.3
26.5
29.1
SHCkW
SHF
0.62
0.70
0.78
0.88
0.95
0.51
0.58
0.66
0.75
0.83
0.93
0.47
0.55
0.63
0.71
0.80
0.90
0.51
0.59
0.67
0.77
0.87
0.97
0.55
0.63
0.72
0.82
0.91
0.58
0.68
0.77
20.0
19.8
19.6
19.3
19.0
20.0
19.8
19.6
19.3
19.0
18.7
19.8
19.6
19.3
19.0
18.7
18.4
19.3
19.0
18.7
18.4
18.1
17.8
18.7
18.4
18.1
17.8
17.5
18.1
17.8
17.5
T/I kW
- 17 -
62.4
64.3
24
58.6
21
23
56.7
20
60.3
64.3
24
22
62.4
23
56.7
20
60.3
54.7
19
22
62.4
23
58.6
60.3
22
21
58.6
21
54.7
19
56.7
52.7
18
20
58.6
56.7
21
54.7
20
50.9
17
52.7
49.0
16
19
54.7
19
18
52.7
49.0
16
18
47.6
15
50.9
50.9
17
17
49.0
47.6
15
16
Q kW
WB ˚C
36.0
38.7
41.6
44.5
47.6
30.2
33.1
36.2
39.3
42.0
44.9
27.5
30.2
33.4
36.3
38.8
42.2
27.5
30.6
33.4
36.9
39.7
42.1
27.9
30.6
33.6
36.3
39.5
27.0
29.9
33.8
SHCkW
-5.0
0.56
0.62
0.69
0.76
0.84
0.47
0.53
0.60
0.67
0.74
0.82
0.44
0.50
0.57
0.64
0.71
0.80
0.47
0.54
0.61
0.70
0.78
0.86
0.51
0.58
0.66
0.74
0.83
0.53
0.61
0.71
SHF
63.6
61.8
59.9
58.0
56.2
63.6
61.8
59.9
58.0
56.2
54.2
61.8
59.9
58.0
56.2
54.2
52.3
58.0
56.2
54.2
52.3
50.5
48.6
54.2
52.3
50.5
48.6
47.2
50.5
48.6
47.2
Q kW
35.6
38.3
41.3
44.7
47.8
29.9
32.8
35.9
38.9
41.6
44.4
27.2
30.0
33.1
36.0
38.5
41.8
27.3
30.3
33.1
36.6
39.4
42.3
27.6
30.3
33.3
36.0
39.2
26.8
30.1
33.5
SHCkW
SHF
0.56
0.62
0.69
0.77
0.85
0.47
0.53
0.60
0.67
0.74
0.82
0.44
0.50
0.57
0.64
0.71
0.80
0.47
0.54
0.61
0.70
0.78
0.87
0.51
0.58
0.66
0.74
0.83
0.53
0.62
0.71
COOLING
PR-15YC
PRH-15YA
PRH-15YA-L
CAPACITY
TOTAL INPUT
AIR VOLUME
13.4
13.3
13.2
13.1
13.0
13.4
13.3
13.2
13.1
13.0
12.9
13.3
13.2
13.1
13.0
12.9
12.8
13.1
13.0
12.9
12.8
12.7
12.6
12.9
12.8
12.7
12.6
12.5
12.7
12.6
12.5
T/I kW
120
2,000
0.944
0.980
CMM
L/S
130
2,170
0.955
0.984
140
2,330
0.966
0.988
150
2,500
0.978
0.992
2,670
0.981
0.996
160
62.8
61.0
59.1
57.3
55.5
62.8
61.0
59.1
57.3
55.5
53.6
61.0
59.1
57.3
55.5
53.6
51.7
57.3
55.5
53.6
51.7
49.9
48.1
53.6
51.7
49.9
48.1
46.8
49.9
48.1
46.8
Q kW
SHC:SENSIBLE HEAT CAPACITY
13.3
13.2
13.1
13.0
12.9
13.3
13.2
13.1
13.0
12.9
12.8
13.2
13.1
13.0
12.9
12.8
12.7
13.0
12.9
12.8
12.7
12.6
12.5
12.8
12.7
12.6
12.5
12.4
12.6
12.5
12.4
T/I kW
0.0
Factor for Various Air Flow
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
0.56
0.62
0.70
0.77
0.85
0.47
0.54
0.61
0.68
0.75
0.83
0.44
0.50
0.57
0.64
0.72
0.81
0.47
0.54
0.61
0.70
0.78
0.87
0.51
0.58
0.66
0.74
0.83
0.53
0.62
0.71
SHF
13.7
13.5
13.4
13.3
13.2
13.7
13.5
13.4
13.3
13.2
13.1
13.5
13.4
13.3
13.2
13.1
13.0
13.3
13.2
13.1
13.0
12.9
12.8
13.1
13.0
12.9
12.8
12.7
12.9
12.8
12.7
T/I kW
2,830
1.0
1.0
170
3,000
1.011
1.005
180
T/I:TOTAL INPUT
35.2
37.8
41.4
44.1
47.2
29.5
32.9
36.1
39.0
41.6
44.5
26.8
29.6
32.7
35.5
38.6
41.9
26.9
30.0
32.7
36.2
38.9
41.8
27.3
30.0
32.9
35.6
38.8
26.4
29.8
33.2
SHCkW
5.0
OUTDOOR DB˚C
PR-15YC
PRH-15YA-L
PRH-15YA
61.8
60.0
58.1
56.3
54.6
61.8
60.0
58.1
56.3
54.6
52.8
60.0
58.1
56.3
54.6
52.8
51.0
56.3
54.6
52.8
51.0
49.2
47.4
52.8
51.0
49.2
47.4
46.2
49.2
47.4
46.2
Q kW
35.2
37.8
41.3
43.9
47.0
29.7
32.4
35.4
38.3
41.0
44.4
27.0
29.6
32.7
35.5
38.0
41.3
27.0
30.0
32.7
36.2
38.9
41.7
27.5
30.1
33.0
35.6
38.8
27.1
29.9
33.3
SHCkW
10.0
0.57
0.63
0.71
0.78
0.86
0.48
0.54
0.61
0.68
0.75
0.84
0.45
0.51
0.58
0.65
0.72
0.81
0.48
0.55
0.62
0.71
0.79
0.88
0.52
0.59
0.67
0.75
0.84
0.55
0.63
0.72
SHF
14.1
13.9
13.8
13.7
13.6
14.1
13.9
13.8
13.7
13.6
13.4
13.9
13.8
13.7
13.6
13.4
13.3
13.7
13.6
13.4
13.3
13.2
13.1
13.4
13.3
13.2
13.1
13.0
13.2
13.1
13.0
T/I kW
60.5
58.8
57.0
55.2
53.5
60.5
58.8
57.0
55.2
53.5
51.7
58.8
57.0
55.2
53.5
51.7
50.0
55.2
53.5
51.7
50.0
48.3
46.6
51.7
50.0
48.3
46.6
45.4
48.3
46.6
45.4
Q kW
34.5
37.6
41.0
43.6
46.5
29.0
32.3
35.3
38.1
40.7
43.9
26.5
29.1
32.0
34.8
37.7
41.0
26.5
29.4
32.1
35.5
38.2
41.0
26.9
29.5
32.4
35.0
38.1
26.6
29.4
32.7
SHCkW
0.57
0.64
0.72
0.79
0.87
0.48
0.55
0.62
0.69
0.76
0.85
0.45
0.51
0.58
0.65
0.73
0.82
0.48
0.55
0.62
0.71
0.79
0.88
0.52
0.59
0.67
0.75
0.84
0.55
0.63
0.72
SHF
14.6
14.4
14.3
14.1
14.0
14.6
14.4
14.3
14.1
14.0
13.8
14.4
14.3
14.1
14.0
13.8
13.7
14.1
14.0
13.8
13.7
13.6
13.5
13.8
13.7
13.6
13.5
13.4
13.6
13.5
13.4
T/I kW
HEATING
PRH-15YA
PRH-15YA-L
27
26
25
24
23
22
21
20
19
CAPACITY
TOTAL INPUT
120
2,000
0.976
1.070
CMM
L/S
130
2,170
0.981
1.056
140
2,330
0.986
1.042
150
2,500
0.990
1.028
160
2,670
0.995
1.014
2,830
1.0
1.0
3,000
1.004
0.991
180
17.4
170
17.3
56.0
15.9
49.4
14.5
43.4
27
T/I : TOTAL INPUT
17.1
56.2
15.7
49.6
14.4
43.6
26
* Q : HEATING CAPACITY
16.9
56.5
15.6
49.8
14.3
43.8
16.8
16.6
16.5
16.3
16.2
16.0
15.8
25
57.0
57.2
57.4
57.6
57.8
58.1
56.7
15.3
15.2
15.1
15.0
14.8
14.7
58.3
15.5
50.2
50.3
50.5
50.6
50.8
51.0
14.6
50.0
14.1
14.0
13.9
13.8
13.6
13.5
51.2
14.2
44.1
44.2
44.3
44.5
44.6
44.8
13.4
43.9
24
23
22
21
20
19
18
45.0
15.7
17
15.5
58.6
14.4
51.4
13.3
45.2
16
T/I kW
58.8
14.3
Q kW
51.6
T/I kW
10.0
Q kW
13.2
T/I kW
OUTDOOR WB ˚C
45.4
Q kW
13.3
15
DB ˚C
INDOOR
13.2
38.0
12.2
33.3
11.3
29.1
PRH-15YA-L
PRH-15YA
13.1
38.2
12.1
33.5
11.2
29.3
13.0
12.9
12.8
12.8
12.7
12.6
12.5
38.4
38.5
38.7
38.8
38.9
39.0
39.2
12.0
11.9
11.8
11.8
11.7
11.7
11.6
33.6
33.7
33.8
34.0
34.1
34.3
34.4
39.3
11.2
11.1
11.1
11.0
11.0
10.9
10.9
11.5
29.4
29.5
29.6
29.8
29.9
30.1
30.2
34.5
12.4
10.8
39.5
11.5
34.7
10.8
30.6
17
30.4
12.3
39.7
11.4
34.9
10.7
18
12.2
39.9
11.4
35.1
10.7
30.8
OPERATION
RANGE
AIR VOLUME
0.0
T/I kW
15.0
Q kW
31.0
-5.0
Q kW
T/I kW
PRH-15YA
16
5.0
-10.0
Q kW
T/I kW
OUTDOOR WB ˚C
PRH-15YA-L
15
INDOOR
DB ˚C
OPERATION
RANGE
Heating Capacity
(Nominal Air Flow):PPRH-15YA, PRH-15YA-L
Factor for Various Air Flow
15.0
Cooling Capacity (Nominal Air Flow)
(Use for low ambient temp. parts):PR-15YC, PRH-15YA, PRH-15YA-L
- 18 -
75.7
78.0
23
24
71.2
21
73.4
69.0
20
22
75.7
78.0
69.0
20
23
24
67.0
19
73.4
75.7
23
22
73.4
22
71.2
71.2
21
69.0
21
65.0
67.0
18
19
20
71.2
69.0
20
21
67.0
19
63.2
17
65.0
67.0
61.3
19
16
18
65.0
61.3
16
18
59.3
15
63.2
63.2
17
17
61.3
16
59.3
Q kW
20.0
44.5
48.4
52.1
56.2
60.0
41.6
37.4
45.5
49.8
53.1
57.0
34.1
38.2
42.0
45.5
54.0
49.6
34.2
38.0
42.2
46.2
50.6
34.8
54.6
39.0
43.0
46.6
50.4
34.8
39.2
42.7
SHCkW
20.9
20.6
20.3
20.0
19.8
20.6
20.9
20.3
20.0
19.8
19.5
20.6
20.3
20.0
19.8
19.3
19.5
20.0
19.8
19.5
19.3
19.1
19.5
19.0
19.3
19.1
19.0
18.7
19.1
19.0
18.7
T/I kW
75.6
73.3
71.0
68.9
66.8
73.3
75.6
71.0
68.9
66.8
64.9
73.3
71.0
68.9
66.8
63.0
64.9
68.9
66.8
64.9
63.0
61.2
64.9
59.5
63.0
61.2
59.5
57.4
61.2
59.5
57.4
Q kW
PR-20YC
PRH-20YA
PRH-20YA-L
COOLING
CAPACITY
TOTAL INPUT
AIR VOLUME
25.0
43.8
47.6
51.1
55.1
58.8
41.0
37.0
44.7
48.9
52.1
55.8
33.0
37.6
41.3
44.8
52.9
48.7
33.8
37.4
41.5
45.4
49.6
34.4
53.6
37.8
41.6
45.8
49.4
33.7
38.1
41.9
SHCkW
0.58
0.65
0.72
0.80
0.88
0.56
0.49
0.63
0.71
0.78
0.86
0.45
0.53
0.60
0.67
0.84
0.75
0.49
0.56
0.64
0.72
0.81
0.53
0.90
0.60
0.68
0.77
0.86
0.55
0.64
0.73
SHF
170
2,830
0.980
0.990
CMM
L/S
180
3,000
0.990
0.995
3,160
1.0
1.0
190
3,330
1.008
1.003
200
SHC:SENSIBLE HEAT CAPACITY
0.57
0.64
0.71
0.79
0.87
0.55
0.48
0.62
0.70
0.77
0.85
0.45
0.52
0.59
0.66
0.83
0.74
0.48
0.55
0.63
0.71
0.80
0.52
0.89
0.60
0.68
0.76
0.85
0.55
0.64
0.72
SHF
Factor for Various Air Flow
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
15
INDOOR INDOOR
DB ˚C
WB ˚C
OPERATION
RANGE
72.8
70.8
68.6
66.6
64.6
70.8
72.8
68.6
66.6
64.6
62.7
70.8
68.6
66.6
64.6
60.9
62.7
66.6
64.6
62.7
60.9
59.2
62.7
57.6
60.9
59.2
57.6
55.4
59.2
57.6
55.4
Q kW
210
3,500
1.017
1.007
220
3,670
1.025
1.010
30.0
43.0
46.7
50.1
54.6
58.1
39.6
35.7
43.9
48.0
51.0
54.5
32.6
37.0
40.6
43.9
51.8
47.7
32.6
36.8
40.8
44.5
48.5
33.2
53.0
37.1
40.8
44.9
48.2
33.2
37.4
40.4
SHCkW
T/I:TOTAL INPUT
22.2
21.8
21.5
21.2
20.8
21.8
22.2
21.5
21.2
20.8
20.5
21.8
21.5
21.2
20.8
20.3
20.5
21.2
20.8
20.5
20.3
20.0
20.5
19.8
20.3
20.0
19.8
19.5
20.0
19.8
19.5
T/I kW
0.59
0.66
0.73
0.82
0.90
0.56
0.49
0.64
0.72
0.79
0.87
0.46
0.54
0.61
0.68
0.85
0.76
0.49
0.57
0.65
0.73
0.82
0.53
0.92
0.61
0.69
0.78
0.87
0.56
0.65
0.73
SHF
23.5
23.1
22.7
22.3
21.9
23.1
23.5
22.7
22.3
21.9
21.6
23.1
22.7
22.3
21.9
21.3
21.6
22.3
21.9
21.6
21.3
21.0
21.6
20.7
21.3
21.0
20.7
20.3
21.0
20.7
20.3
T/I kW
69.9
68.0
66.0
64.0
62.2
68.0
69.9
66.0
64.0
62.2
60.8
68.0
66.0
64.0
62.2
58.7
60.8
64.0
62.2
60.8
58.7
57.0
60.8
55.5
58.7
57.0
55.5
53.4
57.0
55.5
53.4
Q kW
OUTDOOR DB˚C
PR-20YC
PRH-20YA-L
PRH-20YA
41.9
45.6
49.5
53.8
57.2
38.8
35.0
42.9
46.7
50.4
54.1
31.3
35.6
39.7
42.9
51.1
46.8
32.0
35.5
40.1
43.4
47.3
32.2
51.6
35.8
39.9
43.8
47.0
31.9
36.1
39.5
SHCkW
35.0
0.60
0.67
0.75
0.84
0.92
0.57
0.50
0.65
0.73
0.81
0.89
0.46
0.54
0.62
0.69
0.87
0.77
0.50
0.57
0.66
0.74
0.83
0.53
0.93
0.61
0.70
0.79
0.88
0.56
0.65
0.74
SHF
24.8
24.4
23.9
23.5
23.1
24.4
24.8
23.9
23.5
23.1
22.7
24.4
23.9
23.5
23.1
22.4
22.7
23.5
23.1
22.7
22.4
22.0
22.7
21.7
22.4
22.0
21.7
21.3
22.0
21.7
21.3
T/I kW
Cooling Capacity (Nominal Air Flow):PR-20YC, PRH-20YA, PRH-20YA-L
66.7
65.0
63.3
61.4
59.7
65.0
66.7
63.3
61.4
59.7
58.0
65.0
63.3
61.4
59.7
56.4
58.0
61.4
59.7
58.0
56.4
54.8
58.0
53.2
56.4
54.8
53.2
51.4
54.8
53.2
51.4
Q kW
40.0
41.4
44.9
48.7
52.8
56.1
37.7
34.0
41.8
45.4
49.6
52.8
30.6
34.8
38.7
41.8
50.2
45.8
31.3
34.6
38.9
42.3
46.6
31.3
50.5
35.0
38.9
43.1
46.3
31.2
35.1
38.6
SHCkW
0.62
0.69
0.77
0.86
0.94
0.58
0.51
0.66
0.74
0.83
0.91
0.47
0.55
0.63
0.70
0.89
0.79
0.51
0.58
0.67
0.75
0.85
0.54
0.95
0.62
0.71
0.81
0.90
0.57
0.66
0.75
SHF
26.2
25.6
25.2
24.7
24.3
25.6
26.2
25.2
24.7
24.3
23.9
25.6
25.2
24.7
24.3
23.5
23.9
24.7
24.3
23.9
23.5
23.1
23.9
22.7
23.5
23.1
22.7
22.3
23.1
22.7
22.3
T/I kW
62.5
61.1
59.8
58.2
56.5
61.1
62.5
59.8
58.2
56.5
54.9
61.1
59.8
58.2
56.5
53.4
54.9
58.2
56.5
54.9
53.4
51.9
54.9
50.4
53.4
51.9
50.4
48.8
51.9
50.4
48.8
Q kW
46.0
40.0
43.4
47.8
51.8
55.4
36.7
32.5
40.7
44.2
48.0
52.2
28.7
33.5
37.8
40.7
48.6
44.5
30.3
33.3
37.3
41.7
45.7
29.6
49.4
33.6
37.9
41.8
44.9
30.1
34.3
37.6
SHCkW
SHF
0.64
0.71
0.80
0.89
0.98
0.60
0.52
0.68
0.76
0.85
0.95
0.47
0.56
0.65
0.72
0.91
0.81
0.52
0.59
0.68
0.78
0.88
0.54
0.98
0.63
0.73
0.83
0.92
0.58
0.68
0.77
27.8
27.3
26.8
26.2
25.7
27.3
27.8
26.8
26.2
25.7
25.3
27.3
26.8
26.2
25.7
24.9
25.3
26.2
25.7
25.3
24.9
24.5
25.3
24.0
24.9
24.5
24.0
23.6
24.5
24.0
23.6
T/I kW
- 19 -
85.6
24
77.8
21
83.0
75.3
20
80.4
85.6
24
23
83.0
23
22
80.4
75.3
20
22
72.9
19
77.8
83.0
23
21
80.4
22
72.9
19
77.8
70.6
18
21
77.8
21
75.3
75.3
20
20
72.9
68.4
17
19
66.2
16
70.6
72.9
19
18
70.6
66.2
16
18
64.2
15
68.4
68.4
17
17
66.2
64.2
15
16
Q kW
WB ˚C
47.1
51.5
55.5
59.1
62.5
40.2
44.0
47.4
51.3
55.0
59.0
36.5
40.2
44.3
48.2
51.8
55.8
36.6
40.7
44.5
48.7
52.7
56.3
37.2
40.9
45.1
49.0
52.6
37.6
41.0
44.9
SHCkW
-5.0
SHF
0.55
0.62
0.69
0.76
0.83
0.47
0.53
0.59
0.66
0.73
0.81
0.44
0.50
0.57
0.64
0.71
0.79
0.47
0.54
0.61
0.69
0.77
0.85
0.51
0.58
0.66
0.74
0.82
0.55
0.62
0.70
47.5
84.8
18.1
0.56
0.62
0.69
0.76
0.83
0.47
0.53
0.60
0.66
0.73
0.81
0.44
0.50
0.57
0.64
0.71
0.79
0.47
0.54
0.61
0.69
0.77
0.85
0.51
0.58
0.66
0.74
0.82
0.55
0.62
0.70
SHF
COOLING
PR-20YC
PRH-20YA
PRH-20YA-L
CAPACITY
TOTAL INPUT
AIR VOLUME
18.3
18.1
17.9
17.8
17.6
18.3
18.1
17.9
17.8
17.6
17.5
18.1
17.9
17.8
17.6
17.5
17.3
17.8
17.6
17.5
17.3
17.2
17.1
17.5
17.3
17.2
17.1
16.9
17.2
17.1
16.9
T/I kW
83.6
81.2
78.8
76.0
73.7
83.6
81.2
78.8
76.0
73.7
71.4
81.2
78.8
76.0
73.7
71.4
69.3
76.0
73.7
71.4
69.3
67.2
65.2
71.4
69.3
67.2
65.2
63.2
67.2
65.2
63.2
Q kW
170
2,830
0.980
0.990
CMM
L/S
180
3,000
0.990
0.995
3,160
1.0
1.0
190
3,330
1.008
1.003
200
SHC:SENSIBLE HEAT CAPACITY
18.0
54.9
58.7
62.1
39.9
43.7
47.8
51.0
54.6
58.6
36.3
39.8
44.0
47.9
51.4
55.3
36.3
40.4
44.2
48.3
52.4
56.0
36.9
40.6
44.9
48.8
52.4
37.4
40.9
44.7
51.1
79.6
77.2
74.8
84.8
82.4
79.6
77.2
74.8
72.4
82.4
79.6
77.2
74.8
72.4
70.0
77.2
74.8
72.4
70.0
68.0
65.9
72.4
70.0
68.0
65.9
63.9
68.0
65.9
63.9
0.0
SHCkW
82.4
17.8
17.7
17.5
18.1
18.0
17.8
17.7
17.5
17.4
18.0
17.8
17.7
17.5
17.4
17.2
17.7
17.5
17.4
17.2
17.0
16.9
17.4
17.2
17.0
16.9
16.7
17.0
16.9
16.7
T/I kW
Q kW
Factor for Various Air Flow
Note1.* Q :COOLING CAPACITY
30
28
26
24
22
20
DB ˚C
INDOOR INDOOR
OPERATION
RANGE
0.56
0.63
0.70
0.77
0.84
0.47
0.54
0.61
0.67
0.74
0.82
0.44
0.51
0.58
0.65
0.72
0.80
0.47
0.54
0.62
0.70
0.78
0.86
0.51
0.58
0.66
0.75
0.83
0.55
0.62
0.70
SHF
18.7
18.5
18.3
18.1
17.9
18.7
18.5
18.3
18.1
17.9
17.8
18.5
18.3
18.1
17.9
17.8
17.6
18.1
17.9
17.8
17.6
17.5
17.4
17.8
17.6
17.5
17.4
17.2
17.5
17.4
17.2
T/I kW
3,500
1.017
1.007
210
3,670
1.025
1.010
220
T/I:TOTAL INPUT
46.8
51.2
55.2
58.5
61.9
39.3
43.8
48.1
50.9
54.5
58.5
35.7
40.2
44.1
47.9
51.4
55.4
35.7
39.8
44.3
48.5
52.4
56.1
36.4
40.2
44.4
48.9
52.5
37.0
40.4
44.2
SHCkW
5.0
OUTDOOR DB˚C
PR-20YC
PRH-20YA-L
PRH-20YA
82.2
79.8
77.4
75.0
72.6
82.2
79.8
77.4
75.0
72.6
70.2
79.8
77.4
75.0
72.6
70.2
68.2
75.0
72.6
70.2
68.2
66.2
64.2
70.2
68.2
66.2
64.2
62.3
66.2
64.2
62.3
Q kW
46.9
50.3
54.2
57.8
61.7
39.5
43.1
47.2
51.0
54.5
58.3
35.9
39.5
43.5
47.2
50.5
55.2
36.0
39.9
43.5
47.7
51.6
55.9
36.5
40.2
44.4
48.2
51.7
36.4
40.4
43.6
SHCkW
10.0
0.57
0.63
0.70
0.77
0.85
0.48
0.54
0.61
0.68
0.75
0.83
0.45
0.51
0.58
0.65
0.72
0.81
0.48
0.55
0.62
0.70
0.78
0.87
0.52
0.59
0.67
0.75
0.83
0.55
0.63
0.70
SHF
19.2
19.0
18.8
18.6
18.4
19.2
19.0
18.8
18.6
18.4
18.2
19.0
18.8
18.6
18.4
18.2
18.0
18.6
18.4
18.2
18.0
17.9
17.8
18.2
18.0
17.9
17.8
17.6
17.9
17.8
17.6
T/I kW
80.4
78.0
75.6
73.3
71.0
80.4
78.0
75.6
73.3
71.0
68.7
78.0
75.6
73.3
71.0
68.7
66.6
73.3
71.0
68.7
66.6
64.7
62.8
68.7
66.6
64.7
62.8
61.0
64.7
62.8
61.0
Q kW
45.8
49.9
53.7
57.2
61.1
38.6
42.9
46.9
50.6
54.0
57.7
35.1
39.3
43.2
46.9
50.2
54.6
35.2
39.1
43.3
47.3
51.1
55.3
35.7
39.3
43.3
47.7
51.2
35.6
39.6
43.3
SHCkW
15.0
20.0
19.7
19.5
19.2
19.0
20.0
19.7
19.5
19.2
19.0
18.8
19.7
19.5
19.2
19.0
18.8
18.6
19.2
19.0
18.8
18.6
18.4
18.3
18.8
18.6
18.4
18.3
18.1
18.4
18.3
18.1
T/I kW
HEATING
PRH-20YA
PRH-20YA-L
15.0
24.1
24.3
75.0
21.9
66.1
19.8
58.1
27
CAPACITY
TOTAL INPUT
AIR VOLUME
L/S
CMM
170
2,830
0.990
1.025
180
3,000
0.995
1.013
190
3,160
1.0
1.0
200
3,330
1.003
0.993
3,500
1.007
0.987
3,670
1.010
0.980
220
23.8
75.3
21.7
66.4
19.7
58.4
26
210
23.6
75.6
21.5
66.7
19.5
58.7
25
T/I : TOTAL INPUT
23.3
76.0
21.4
67.0
19.4
59.0
24
* Q : HEATING CAPACITY
23.1
76.3
21.2
67.3
19.2
59.2
22.9
22.7
22.5
22.3
22.1
21.9
21.7
T/I kW
23
77.0
77.3
77.6
77.9
78.2
78.5
78.8
76.6
20.8
20.6
20.5
20.3
20.2
20.0
19.8
21.0
67.8
68.0
68.3
68.5
68.8
69.1
69.4
Q kW
67.6
19.0
18.8
18.7
18.6
18.4
18.3
18.1
T/I kW
10.0
Q kW
19.1
59.6
59.8
60.0
60.2
60.4
60.6
60.9
T/I kW
OUTDOOR WB ˚C
59.4
22
21
20
19
18
17
16
15
DB ˚C
INDOOR
OPERATION
RANGE
Q kW
18.0
5.0
17.9
50.9
16.5
44.4
15.2
38.6
27
PRH-20YA-L
PRH-20YA
17.8
51.2
16.4
44.7
15.1
25
38.9
17.7
17.6
17.4
17.3
17.2
17.1
17.0
26
51.6
51.8
52.0
52.2
52.4
52.6
51.4
16.3
16.2
16.1
16.0
15.9
15.8
16.3
45.1
45.3
45.5
45.7
45.9
46.1
44.9
15.0
14.9
14.8
14.7
14.7
14.6
52.8
15.0
39.2
39.4
39.6
39.8
40.0
40.2
15.7
39.1
24
23
22
21
20
19
46.3
16.9
14.5
16.8
53.1
15.6
46.5
14.4
40.6
17
40.4
16.7
53.3
15.5
46.7
14.3
40.9
16
18
T/I kW
53.5
15.4
46.9
14.3
41.2
15
Q kW
T/I kW
0.0
PRH-20YA
Q kW
-5.0
OUTDOOR WB ˚C
PRH-20YA-L
T/I kW
-10.0
Q kW
DB ˚C
INDOOR
OPERATION
RANGE
Heating Capacity
(Nominal Air Flow):PRH-20YA, PRH-20YA-L
Factor for Various Air Flow
0.57
0.64
0.71
0.78
0.86
0.48
0.55
0.62
0.69
0.76
0.84
0.45
0.52
0.59
0.66
0.73
0.82
0.48
0.55
0.63
0.71
0.79
0.88
0.52
0.59
0.67
0.76
0.84
0.55
0.63
0.71
SHF
Cooling Capacity (Nominal Air Flow)
(Use for low ambient temp. parts):PR-20YC, PRH-20YA, PRH-20YA-L
Outdoor temp.(˚CDB)
10
0
-10
40
30
Range for
continuous operation
40
30
-10
20
0
10
PRH-YA-L
10
15
15
20
20
Outdoor temp.(˚CWB)
Range for
continuous operation
24 25
24 25
10
0
-10
Range for
continuous
operation
Use for Low
temp.parts
30
Range for
continuous operation
40
10
15
20
30
Indoor temp.(˚CWB)
- 2020
24 25
50
46
50
46
10
5
30
Range for
continuous operation
Outdoor temp.(˚CDB)
PR-YC
10
5
0
-5
Range for continuous operation
10
Range for
continuous
operation
Use for Low
temp.parts
PRH-YA
Outdoor temp.(˚CWB)
Range for
continuous
operation
Use for Low
temp.parts
Outdoor temp.(˚CDB)
Operation range
Cooling
50
46
20
30
Indoor temp.(˚CWB)
Cooling
Heating
15
0
-5
-10
10
Indoor temp.(˚CWB)
Cooling
10
15
15
20
20
25 27 30
Indoor temp.(˚CDB)
Heating
15
-10
25 27 30
Indoor temp.(˚CDB)
FAN PERFORMANCE
Airflow
PR-5YC
PRH-5YA
PRH-5YA-L
CMM
L/S
Operation range
External static pressure (Pa)
700
100
Fan speed
(rpm)
600
200
500
External
static
pressure
(Pa)
1800
1700
400
300
1600
1.1kW
1500
300
1400
200
1300
100
0.75kW
1200
1100
45
750
400
50
830
60
1000
(CMM)
( / s)
FAN SPEED
rpm
PULLEYSIZE
(MOTOR SIDE)
mm
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
Airflow
45
750
1230
139.7
5.5
165.1
6.5
B39
0.75
1330
139.7
5.5
152.4
6
B38
0.75
1450
139.7
5.5
139.7
5.5
B37
0.75
1610
127
5.0
114.3
4.5
B35
0.75
50
830
1320
127
5
139.7
5.5
B36
0.75
1450
139.7
5.5
139.7
5.5
B37
0.75
1580
152.4
6
139.7
5.5
B40
1.1
-
55
920
1450
139.7
5.5
139.7
5.5
B37
0.75
1580
152.4
6
139.7
5.5
B40
1.1
1610
127
5
114.3
4.5
B37
1.1
-
60
1000
1450
139.7
5.5
139.7
5.5
B39
1.1
1600
139.7
5.5
127
5
B39
1.1
-
Std.
Airflow
CMM
L/S
PR-8YC
PRH-8YA
PRH-8YA-L
100
Operation range
Fan speed (rpm)
External static pressure (Pa)
600
1800
500
200
1700
External
static
pressure
(Pa)
1600
400
1.5kW
1500
300
1400
1.1kW
300
1300
200
100
FAN SPEED
rpm
PULLEYSIZE
(MOTOR SIDE)
PULLEYSIZE
mm
inch
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
1200
MOTOR
kw
1100
FAN SPEED
rpm
1000
400
60
1000
70
1170
80
1330
90
1500
(CMM)
( / s)
Airflow
500
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
Std.
- 21 -
60
1000
1000
114.3
4.5
165.1
6.5
B39
1.1
1230
139.7
5.5
165.1
6.5
B41
1.1
1450
127
5.0
127
5.0
B38
1.1
1580
152.4
6.0
139.7
5.5
B40
1.1
1740
152.4
6.0
127
5.0
B39
1.1
70
1170
1090
114.3
4.5
152.4
6.0
B39
1.1
1320
127
5.0
139.7
5.5
B39
1.1
1450
127
5.0
127
5.0
B38
1.1
1600
139.7
5.5
127
5.0
B39
1.1
1740
152.4
6.0
127
5.0
B36
1.5
80
1330
1310
114.3
4.5
127
5.0
B37
1.1
1450
127
5.0
127
5.0
B38
1.1
1580
152.4
6
139.7
5.5
B37
1.5
1690
177.8
7.0
152.4
6.0
B39
1.5
-
90
1500
1310
114.3
4.5
127
5.0
B37
1.5
1450
127
5.0
127
5.0
B35
1.5
1600
139.7
5.5
127
5.0
B35
1.5
-
95
1580
1450
127
5.0
127
5.0
B35
1.5
1580
152.4
6.0
139.7
5.5
B37
1.5
-
PR-10YC
PRH-10YA
PRH-10YA-L
CMM
L/S
FAN SPEED
Operation range
PULLEYSIZE
100
External static pressure (Pa)
600
External
static
pressure
(Pa)
1800
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
200
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
1600
300
2.2kW
1400
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
300
200
100
inch
BELT SIZE
1700
1500
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
1.5kW
1300
1200
90
1500
110
1830
100
1670
120
2000
(CMM)
( / s)
mm
inch
mm
(FAN SIDE)
Fan speed
(rpm)
500
400
rpm
PULLEYSIZE
(MOTOR SIDE)
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
400
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
Airflow
Airflow
90
1500
1320
127
5.0
139.7
5.5
B35
1.5
1450
139.7
5.5
139.7
5.5
B36
1.5
1580
152.4
6
139.7
5.5
B37
1.5
1710
165.1
6.5
139.7
5.5
B35
2.2
100
1660
1450
139.7
5.5
139.7
5.5
B36
1.5
1450
139.7
5.5
139.7
5.5
B36
1.5
1600
139.7
5.5
127
5.0
B33
2.2
1740
152.4
6.0
127
5.0
B34
2.2
110
1830
1450
139.7
5.5
139.7
5.5
B33
2.2
1600
139.7
5.5
127
5.0
B33
2.2
1740
152.4
6.0
127
5.0
B34
2.2
-
120
2000
1550
190.5
7.5
177.8
7.0
B39
2.2
-
Std.
Airflow
PR-15YC
PRH-15YA
PRH-15YA-L
CMM
L/S
FAN SPEED
PULLEY SIZE
(MOTOR SIDE)
800
PULLEYSIZE
100
Operation range
External
static
pressure
(Pa)
Fan speed
(rpm)
200
700
External static pressure (Pa)
600
1200
300
3.0kW
500
1100
400
1000
300
900
400
800
200
700
500
600
140
2330
160
2670
180
3000
(CMM)
( / s)
600
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
Std.
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEYSIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
Airflow
- 22 -
inch
BELT SIZE
PULLEYSIZE
100
120
2000
(FAN SIDE)
PULLEYSIZE
2.2kW
rpm
mm
inch
mm
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
120
2000
640
101.6
4.0
228.6
9.0
B37 2
2.2
760
127
5.0
241.3
9.5
B40 2
2.2
910
127
5.0
203.2
8.0
B37 2
2.2
1040
127
5.0
177.8
7.0
B35 2
2.2
1120
127
5.0
165.1
6.5
B34 2
2.2
1210
127
5.0
152.4
6.0
B33 2
3
130
2170
640
101.6
4.0
228.6
9.0
B37 2
2.2
810
127
5.0
228.6
9.0
B39 2
2.2
910
127
5.0
203.2
8.0
B37 2
2.2
1040
127
5.0
177.8
7.0
B35 2
2.2
1140
139.7
5.5
177.8
7.0
B36 2
3.0
1230
139.7
5.5
165.1
6.5
B35 2
3
140
2330
690
114.3
4.5
241.3
9.5
B39 2
2.2
810
127
5.0
228.6
9.0
B39 2
2.2
910
127
5.0
203.2
8.0
B37 2
2.2
1040
127
5.0
177.8
7.0
B35 2
3.0
1120
127
5.0
165.1
6.5
B34 2
3.0
1230
139.7
5.5
165.1
6.5
B35 2
3
150
2500
730
127
5.0
254
10.0
B41 2
2.2
850
127
5.0
215.9
8.5
B38 2
2.2
970
127
5.0
190.5
7.5
B36 2
2.2
1040
127
5.0
177.8
7.0
B35 2
3.0
1120
127
5.0
165.1
6.5
B34 2
3.0
-
160
2670
730
127
5.0
254
10.0
B41 2
2.2
890
139.7
5.5
228.6
9.0
B39 2
2.2
1000
139.7
5.5
203.2
8.0
B37 2
3.0
1040
127
5.0
177.8
7.0
B35 2
3.0
-
170
2830
760
127
5.0
241.3
9.5
B40 2
2.2
890
139.7
5.5
228.6
9.0
B39 2
2.2
970
127
5.0
190.5
7.5
B36 2
3.0
1040
127
5.0
177.8
7.0
B35 2
3.0
-
180
3000
810
127
5.0
228.6
9.0
B39 2
2.2
910
127
5.0
203.2
8.0
B37 2
3.0
1040
127
5.0
177.8
7.0
B35 2
3.0
-
Airflow
CMM
L/S
PR-20YC
PRH-20YA
PRH-20YA-L
FAN SPEED
PULLEY SIZE
(MOTOR SIDE)
100
Operation range
700
External static pressure (Pa)
600
External
static
pressure
(Pa)
200
Fan speed
(rpm)
300
1200
500
1100
400
400
4.0kW
1000
300
900
3.0kW
500
200
800
100
700
600
170
2830
180
3000
200
3330
220
3670
(CMM)
( / s)
Airflow
PULLEY SIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEY SIZE
mm
(MOTOR SIDE)
inch
PULLEY SIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEY SIZE
mm
(MOTOR SIDE)
inch
PULLEYSIZE
mm
(FAN SIDE)
inch
BELT SIZE
MOTOR
inch
kw
FAN SPEED
rpm
PULLEY SIZE
mm
(MOTOR SIDE)
inch
PULLEY SIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEY SIZE
mm
(MOTOR SIDE)
inch
PULLEY SIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
FAN SPEED
rpm
PULLEY SIZE
mm
(MOTOR SIDE)
inch
PULLEY SIZE
mm
(FAN SIDE)
inch
BELT SIZE
inch
MOTOR
kw
Std.
- 23 -
rpm
mm
inch
170
2830
730
127
5.0
254
10.0
B43 2
3.0
850
127
5.0
215.9
8.5
B40 2
3.0
940
139.7
5.5
215.9
8.5
B41 2
3.0
1040
127
5.0
177.8
7.0
B37 2
3.0
1140
139.7
5.5
177.8
7.0
B38 2
4
1230
139.7
5.5
165.1
6.5
B37 2
4.0
180
3000
810
127
5.0
228.6
9.0
B41 2
3.0
910
127
5.0
203.2
8.0
B39 2
3.0
1000
139.7
5.5
203.2
8.0
B40 2
3.0
1040
127
5.0
177.8
7
B37 2
4.0
1120
127
5.0
165.1
6.5
B36 2
4
-
190
3170
810
127
5.0
228.6
9.0
B41 2
3.0
910
127
5.0
203.2
8.0
B39 2
3.0
1040
127
5.0
177.8
7.0
B37 2
4.0
1060
139.7
5.5
190.5
7.5
B39 2
4.0
-
200
3330
840
139.7
5.5
241.3
9.5
B42 2
3.0
910
127
5.0
203.2
8.0
B39 2
3.0
1040
127
5.0
177.8
7.0
B37 2
4.0
1120
127
5.0
165.1
6.5
B36 2
4.0
-
210
3500
910
127
5.0
203.2
8.0
B39 2
3.0
1000
139.7
5.5
203.2
8.0
B40 2
4.0
1040
127
5.0
177.8
7.0
B37 2
4.0
-
220
3670
940
139.7
5.5
215.9
8.5
B41 2
4.0
970
127
5.0
190.5
7.5
B38 2
4.0
-
Pulley outside dimensions are shown below: (Unit : mm)
(1) Shape of belt groove
e
f
Sectional plan of V-belt
w
L0
Shape of Nominal
a W
V-belt Dia. øP.C ( ˚ )
r3
øP.C
K0
a
r2 r2
11.0mm
r1
L0
K
K0
e
f
r1
r2
r3
V-belt
thickness
(Reference)
1~2
11
K
16.5mm
B
40˚
Over 125
Under 160
Over 160
Under 200
36 16.07 12.5 5.5
Over 200
38 16.29
34 15.86
9.5 19.0 12.5 0.2~0.5 0.5~1.0
B type
(2) Shape of motor pulley boss (Unit : mm)
C
B
A
MOTOR
CAPACITY
(kW)
A
B
+0.009
0
0.75
19 - 0.004 15.5 - 0.2
6
1.1
0
24 +0.009
- 0.004 20.0 - 0.2
8
1.5
24 +0.009
- 0.004
28 +0.009
- 0.004
0
- 0.2
0
- 0.2
8
0
- 0.2
0
- 0.2
8
2.2, 3.0
20.0
23.9
28 +0.009
- 0.004
38 +0.018
- 0.002
4.0
5.5
23.9
33.0
+0.073
+0.040
+0.073
+0.040
+0.073
+0.040
+0.073
+0.040
8
10
+0.073
+0.040
+0.089
+0.050
PR-8 20
PRH-8 20
PR-5
PRH-5
PR-15,20
PRH-15, 20 Pulley for blower & motor
b
b
a
a
c
MODEL
PR-5
PRH-5
PR-8,10
PRH-8, 10
PR-15,20
PRH-15, 20
PR-5 10
PRH-5 10 Pulley for blower & motor
C
a
b
-0.020
-0.007
-0.020
-0.007
-0.020
-0.007
20
20
25
19
16.5
21.0
c
0
- 0.1
0
- 0.1
0
- 0.1
6 - 00.036
8 - 00.036
(3) Shape of motor (Unit : mm)
L
SHAFT
Diameter
Limits
+0.009
19 to 28
-0.004
+0.018
32 to 48
-0.002
AC
TBW
AD
AE
ED
E
øD
+0
H -0.5
Shaft
tapped
DH x EH
deep
TBH
+0
G -0.2
F
AA
HA
EB
Holes
K Dia.
LL
AA
A CRS
E
C
B CRS
BC
AB
BB
Frame
Fixing
OUT PUT
Size
A
0.75
80
1.1
Shaft
B
General
C
H
K
D
E
F
125 100
50
80
10
19
40
6
90SN
140 100
56
90
10
24
50
8
G
ED
DH
EH
AA
AB
AE
EB
15.5 25
M6
16
27
157 127
13.5 295
4
158 132 102
1.5
75
M8
19
28
174 152
38.5 320
4
178 140 110
1.5
100 103 103
13.5 320
20
32
20
BB
BC
L
HA
AC
AD
LL TBW TBH
103 103
1.5
90N
140 125
56
90
10
24
50
8
32
M8
19
28
174 152
4
178 140 110
1.5
100 103 103
2.2,3.0
100L
160 140
63
100
12
28
60
8
23.9 40
M10
22
28
184 170
15
371
4
208 138 120
1.6
23
103 103
4.0
112M
190 140
70
112
12
28
60
8
23.9 40
M10
22
35
218 170
15
377
4
215 164 130
1.6
23
131 131
5.5
132S
216 140
89
132
12
38
80
10
M12
28
38
243 208
53
458
5
257 189 154
1.6
26
131 131
33
56
- 24 -
NC CURVES
PR-5YC
PRH-5YA
PRH-5YA-L
50Hz
CONDITION
A scale
63 Hz
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
COOLING &
HEATING
62db
67
63
62
61
57
50
45
43
90
80
NC-70
octave-band lebel db (0db=0.0002ubar)
70
NC-60
60
NC-50
50
NC-40
40
NC-30
30
NC-20
20
10
over
all
45
63
90
125
180
250
355
500
710
1000
1400
2000
2800
4000
5600
8000
octave-band frequency [Hz]
Note. The measuring point is 1m from the comp. service panel.
50Hz
CONDITION
A scale
63 Hz
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
COOLING &
HEATING
64db
70
67
62
60
58
56
52
50
90
80
NC-70
70
octave-band lebel db (0db=0.0002ubar)
PR-8YC
PRH-8YA
PRH-8YA-L
NC-60
60
NC-50
50
NC-40
40
NC-30
30
NC-20
20
10
over
all
45
63
90
125
180
250
355
500
710
1000
1400
2000
2800
4000
octave-band frequency [Hz]
Note. The measuring point is 1m from the comp. service panel.
- 25 -
5600
8000
PR-10YC
PRH-10YA
PRH-10YA-L
50Hz
CONDITION
A scale
63 Hz
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
COOLING &
HEATING
64db
71
69
63
61
59
57
49
44
90
80
NC-70
octave-band lebel db (0db=0.0002ubar)
70
NC-60
60
NC-50
50
NC-40
40
NC-30
30
NC-20
20
10
over
all
45
63
90
125
180
250
355
500
710
1000
1400
2000
2800
4000
5600
8000
octave-band frequency [Hz]
Note. The measuring point is 1m from the comp. service panel.
50Hz
CONDITION
A scale
63 Hz
125 Hz
250 Hz
COOLING &
HEATING
68db
76
76
68
500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz
65
62
59
51
48
90
80
NC-70
70
octave-band lebel db (0db=0.0002ubar)
PR-15YC
PRH-15YA
PRH-15YA-L
NC-60
60
NC-50
50
NC-40
40
NC-30
30
NC-20
20
10
over
all
45
63
90
125
180
250
355
500
710
1000
1400
2000
2800
4000
octave-band frequency [Hz]
Note. The measuring point is 1m from the comp. service panel.
- 26 -
5600
8000
PR-20YC
PRH-20YA
PRH-20YA-L
50Hz
CONDITION
A scale
63 Hz
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
COOLING &
HEATING
68db
73.5
77
70
65
60
58
51
48
90
80
NC-70
octave-band lebel db (0db=0.0002ubar)
70
NC-60
60
NC-50
50
NC-40
40
NC-30
30
NC-20
20
10
over
all
45
63
90
125
180
250
355
500
710
1000
1400
2000
2800
4000
5600
8000
octave-band frequency [Hz]
Note. The measuring point is 1m from the comp. service panel.
OUTLINE DIMENSIONS
1030
25
16-ø3.5 HOLES
(1030)
25
10
CONDENSER AIR OUTLET
25
15
200
200
200
65
25
200
10
850
300
20 130 130
742
20
A
65
25
25
PR-5YC
PRH-5YA
PRH-5YA-L
SUPPLY AIR DUCT FLANGE
25
410
742
180
25
A(DETAIL)
180
RETURN AIR DUCT FLANGE
25
6-15X25 MTG HOLES
10
75
50
900
50
40
1000
40
607
65
300
42
470
199
1000
1080
30
16-ø3.5 HOLES
944
CONDENSER AIR INLET
(2 SIDES)
54.5
80
424
26.5
410
22
971
210
CONTROL BOX
49
RETURN AIR
22
210
1600
49
SUPPLY AIR
54.5
210
65
25
850
75
210
10
900
30
DRAIN 1B PT
1534
- 27 -
WIRING HOLE
80
4- ø25
SASPENSION HOLES
PR-8,10YC
PRH-8, 10YA
PRH-8, 10YA-L
20-ø3.5 HOLES
(1330)
25
35
180
180
180
180
180
180
10
A
742
65
35
1150
25
15
CONDENSER AIR
OUTLET
65
25
10
1330
300
20 130 130 20
25
SUPPLY AIR DUCT FLANGE
25
410
180
25
A(DETAIL)
6-15X25 MTG HOLES
25
742
180
RETURN AIR DUCT FLANGE
1200
190
190
190
10
190
190
30
65
25
65
190
10
30
1150
1200
1300
75
50
40
1600
49
20-ø3.5 HOLES
607
944
470
300
42
75
50
40
1000
199
SUPPLY AIR
CONTROL BOX
49
22
54.5
1271
1380
80
DRAIN 1B PT
424
PR-15,20YC
PRH-15, 20YA
PRH-15, 20YA-L
80
4-ø25
SASPENSION HOLES
26-ø3.5 HOLES
2010
25
150 200
200
200
200
200
200
200 150
60
10
60
CONDENSER AIR OUTLET
62
25 37
25
2010
15
62
10
A
827
25
SUPPLY AIR DUCT FLANGE
6-15X25 MTG HOLES
200
200
200
200
1879
200 200
200
200
200
39.5
10
62
25
10
62
39.5
200
32
862
RETURN AIR DUCT FLANGE
200
464
32
A (DETAIL)
200 14
1820
14 200
25
WIRING HOLE
1534
428
22
54.5
26.5
410
CONDENSER AIR INLET
(2 SIDES)
RETURN AIR
85
1820
85
55.5
1879
55.5
35
1990
35
26-ø3.5 HOLES
1840
43
717
1080
990
428
24
540
22
54.5
22
1951
54.5
235
101
26.5
RETURN AIR
49
RETURN AIR
CONTROL BOX
CONDENSER
AIR INLET
(3 SIDES)
464
1200
SUPPLY AIR
131
WIRING HOLE
DRAIN 1B PT
556.5
2060
1742.7
- 28 -
4-ø25
SUSPENSION HOLES
37
WIRING DIAGRAMS
PR-5, 8, 10YC (STANDARD)
Power Supply
3Phase
CIRCUIT BREAKER
(FIELD SUPPLY)
380~415Volt
PR- 5YC ···40A
PR- 8YC ···50A
PR-10YC ···60A
50Herts
TB1
L1
L2
L3
WHITE
51C
52C
RED
RED
WHITE
WHITE
51F2
RED
WHITE
BLUE
R1
TB2
S1
BLACK
PE
T1
52F
TB2
RED
R2
WHITE
S2
BLACK
T2
51F1
1
2
3
WHITE
TB3
RED
WHITE
MF2
BLACK
RED
RED
F
INTERNAL
PROTECTOR
BLACK
BLACK
BLACK
N
MC
RED
F
(3.15A)
MF1
INTERNAL
PROTECTOR
BLACK
11
11
TB4
1
SWITCH BOX
(FIELD SUPPLY)
15
51F1
F
(3.15A)
SW1
RL
GL
51F2
FZ1
52C
23
WA
63H
SW2
Tr
51 C
AC
220~
240V
AC
24V
1
2
TB4
3
5
4
6
26L
CZ
CZ
CH
52F
CZ
3
FZ0
FZ1
TM
8,20YC ONLY
(3MIN)
30
CZ
FZ0
FZ1
7
TB3
52C
30
CZ
TM
30
CZ
52C
12 TB3
12
Caution,
1.To protect each Fan motors and Compressors from abnormal current,
these Over current relays<51C>,<51F1,2>are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressor from frequently "ON-OFF" ,timer<TM>is
installed. Therefore,do not change factory set value of this timer.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 29 -
Symbol
MC
MF1
MF2
52C
52F
TB1~4
CH
F
Tr
51C
51F1, 2
63H
26L
TM
FZ0·1
CZ
30CZ
<SW1>
<SW2>
<GL>
<RL>
<23WA>
Name
Compressor motor
Fan motor (in door)
Fan motor (out door)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse
Transformer
O v e r c u r r e n t r e l a y ( compressor)
O v e r c u r r e n t r e l a y (fan I/D,O/D)
High-pressure switch
Thermostat(freeze protection)
Timer (anti short cycle)
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Switch (off)
Switch (on)
Lamp (operation)
Lamp (check)
Thermostat (room temp.)
PR-15, 20YC (STANDARD)
CIRCUIT BREAKER
(FIELD SUPPLY)
PR -15YC···100A
PR -20YC···125A
Power supply
3Phase
380~415Volt
50Hertz
TB1
L1
Red
MC1
52C1
Red
L2
White
White
L3
Black
Black
51C1
INTERNAL
PROTECTOR
Red
Black
51F2
Red
N
Blue
White
Black
PE
52C2
Red
51C2
Red
MC2
Red
TB2
R 11
R 12
1
Red
White
S 11
S 12
2
White
Black
T 11
T 12
3
Black
MF2
INTERNAL
PROTECTOR
White
White
Black
Black
Black
51F3
51F1
52F
Red
Red
White
INTERNAL
PROTECTOR
Red
TB3
R 21
R 22
1
Red
White
S
22
2
White
Black
T 21
T 22
3
Black
S
21
MF3
INTERNAL
PROTECTOR
MF1
Black
F
Red
F(3.15A)
TB4 11
TB4 14
TB5
SWITCH BOX
(FIELD SUPPLY)
1
51F1
FZ0
F
30
CZ1-2
(3.15A)
RL1
23WA
High
RL2 SW1
30
CZ2-2
GL
Low
51F2
AC
220~
240V
52
C2
CZ1
AC
24V
TB5
2
3
4
5
6
7
CZ2
63
H1
52 52
C1 C2
1
26
L1
FZ0
CZ2
CH2
63
H2
CZ1
51C1
8
CZ1
52
C1
51F3
SW2
Tr
52
F
CZ2
51C2
TM
(3MIN)
52
C1
1
52
C2
TM
(3MIN)
26
L2
3
3
FZ1
FZ1
TM
CH1
30
CZ1-1
30
CZ2-1
FZ0
2
52
C1
30
CZ1
(2SEC)
30
CZ2
2
FZ1
30
CZ1-1
9
30
CZ1-2
30
CZ2-1
52
C2
30
CZ2-2
TB4 12
TB412
Caution,
1.To protect each Fan motors and Compressors from abnormal current,
these Over current relays <51C1,2> , <51F1,2,3> are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressors from frequently "ON-OFF" ,timer <TM> is
installed. Therefore,do not change factory set value of this timer.
3.This timer <2> installed so that two compressors may never start at
the same time. The unit stop if the set value of the timer is changed.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 30 -
Symbol
MC1·2
MF1
MF2·3
52C1·2
52F
TB1~5
CH1·2
F
Tr
51C1·2
51F1~3
63H1·2
26L1·2
TM
2
FZ0·1
CZ1·2
30CZ1-1,2
30CZ2-1,2
<SW1>
<SW2>
<GL>
<RL1·2>
<23WA>
Name
C ompressor motor
Fan motor (in door)
Fan motor (out door)
C ontactor (compressor)
C ontactor (fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
Over current relay(compre ssor)
Over current relay (fan I/D, O/ D)
H igh-pressure sw itch
Thermostat(freeze protecti on)
Timer (anti short cycle)
Timer
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Auxiliary relay (check)
Sw itch (off)
Sw itch (on)
Lamp (pow er on)
Lamp (check)
Thermostat (room temp.)
PR-5, 8, 10YC
(SPECIAL ORDER : K CONTROL)
Power supply
3Phase
380~415Volt
50Hertz
TB1
L1
Red
CIRCUIT BREAKER
(FIELD SUPPLY)
PR- 5YC ···40A
PR- 8YC ···50A
PR-10YC ···60A
MC
51C
52C
Red
L2
White
White
L3
Black
Black
Red
Black
51F2
N
Blue
PE
52F
DSA
CN
1
3
Red
51F1
Black
R2
1
Red
S2
2
White
T1
T2
3
Black
MF2
Red
White
Blue
TB2
S1
R1
Black
MF1
Green/Yellow
INTERNAL
PROTECTOR
F(3.15A)
TB3 11
11
TH2
15
30
CZ
IB
FZ
A
B
C
51F1
51F2
63H
D TB4
CZ
FZ
52F
51C
Tr
TH5
CZ
52C
FZ
CH
30
CZ
R/C
52C
30
CZ
8,10YC ONLY
TB3 12
TB3 12
Caution,
To protect each Fan motors and Compressor from abnormal current,
these Over current relays<51C>,<51F1,2>are installed.
Therefore,do not change factory set value of these Over current relays.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 31 -
Symbol
MC
MF1
MF2
52C
52F
TB1~4
CH
F
Tr
51C
51F1,2
63H
FZ
CZ
30CZ
IB
TH2
TH5
R/C
DSA
Name
C ompressor motor
Fan motor(indoor)
Fan motor(outdoor)
C ontactor(compressor)
C ontactor(fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
Over current relay(compressor)
Over current relay(fanI/D ,O /D )
H igh-pressure sw itch
Auxiliary relay(fan)
Auxiliary relay(compressor)
Auxiliary relay(check)
Indoor board
Thermistor(pipe)
Thermistor(room temp.)
R emote controller
Surge absorber circuit board
INTERNAL
PROTECTOR
PR-5, 8, 10YC
(SPECIAL ORDER : LOW TEMPERATURE)
Power supply
3Phase
380~415Volt
50Hertz
TB1
L1
Red
CIRCUIT BREAKER
(FIELD SUPPLY)
PR - 5YC ···40A
PR - 8YC ···50A
PR -10YC ···60A
MC
52C
L2
White
L3
Black
N
Red
51C
Red
White
Black
Black
51F2
TB2
R1
R1
Blue
PE
52F1
Red
51F1
S1
White
T1
T1
Black
Red
Red
R2
R2
1
Red
S2
S2
2
White
T2
T2
3
Black
White
Black
51F3
MF2
52F3
White
Black
Black
TB2
52F2
Red
S1
MF1
Tr1
52F4
INTERNAL
PROTECTOR
F(3.15A)
TB3 11
11
51F3
TB4
1
SWITCH BOX
(FIELD SUPPLY)
15
14
F
(3.15A)
51F1
RL
23WA
FZ1
51F2
26D3
SW2
Tr2
AC
220~
240V
SW1
GL
63H
AC
24V
FZ
2
FZ
2
FZ
4
51 C
2
3
4
5
6
TB4
52
F1
26D4
52
F2
FZ2
CZ
1
CZ
CZ
3
TM
(3MIN)
52
C
FZ3
FZ1
30
CH
CZ
30
CZ
FZ1
FZ0
FZ
3
52C
TM
FZ4
30
CZ
7
8,10YC ONLY
52
F4
52
F3
26L
FZ0
52C
FZ
3
12
TB3 12
Caution,
1.To protect each Fan motors and Compressor from abnormal current,
these Over current relays<51C>,<51F1,2,3>are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressor from frequently "ON-OFF" ,timer<TM>is
installed. Therefore,do not change factory set value of this timer.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 32 -
Symbol
MC
MF1
MF2
52C
52F1
TB1~4
CH
F
Tr1·2
51C
51F1,2,3
63H
26L
TM
FZ0,1
CZ
30CZ
<SW1>
<SW2>
<GL>
<RL>
<23WA>
52F2~4
FZ2~4
Name
C ompressor motor
Fan motor (indoor)
Fan motor (outdoor)
C ontactor (compressor)
C ontactor (fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
Over current relay(compressor)
Over current relay(fanI/D ,O /D )
H igh-pressure sw itch
Thermostat(freeze protection)
Timer (anti short cycle)
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Sw itch (off)
Sw itch (on)
Lamp (operation)
Lamp (check)
Thermostat (room temp.)
C ontactor (fan O/D )
Auxiliary relay (fan O /D )
INTERNAL
PROTECTOR
PR-15, 20YC
(SPECIAL ORDER : LOW TEMPERATURE)
CIRCUIT BREAKER
(FIELD SUPPLY)
PR -15YC···100A
PR -20YC···125A
Power supply
3Phase
380~415Volt
50Hertz
TB1
L1
Red
MC1
52C1
Red
L2
White
White
L3
Black
Black
51C1
INTERNAL
PROTECTOR
Red
Black
51F2
Red
N
Blue
White
Black
PE
52C2
Red
51C2
Red
MC2
Red
Red
S 11
S 11
White
T 11
T 11
Black
INTERNAL
PROTECTOR
TB2
52F2
Red
White
51F4
52F3
Black
R 12
R 12
1
Red
S 12
S 12
2
White
T 12
T 12
3
Black
MF2
White
White
Black
Black
Black
51F3
TB3
R 21 R 21
Red
S 21 S 21
White
T 21
Black
T 21
TB3
52F5
Red
White
51F1
52F
Red
Red
White
R 22
1
Red
S 22
S
22
2
White
T 22
T 22
3
Black
INTERNAL
PROTECTOR
52F4
MF3
INTERNAL
PROTECTOR
52F7
Tr2
MF1
Black
Tr1
R 22
Black
51F5
52F6
F
TB2
R 11 R 11
F(3.15A)
TB4 11
TB5
SWITCH BOX
(FIELD SUPPLY)
1
51F1
FZ0
TB4 11
F
30
CZ1-2
(3.15A)
RL1
23WA
High
Low
RL2 SW1
52
C2
51F5
51F3
CZ1
AC
24V
TB5
2
3
4
5
6
7
CZ2
63
H1
52
F
FZ
2
TM
(3MIN)
52
C1
1
26
L2
30
CZ2-1
52
C1
30
CZ1
TB4 12
30
CZ1-1
30
CZ1-2
FZ
6
FZ
7
52
F5
FZ5
(2SEC)
30
CZ2
52
F7
52
F6
FZ6
FZ3
2
30
CZ2-1
52
F4
52
F3
FZ
3
FZ
6
2
FZ1
10
FZ
5
26D4
52
F2
FZ2
FZ1
FZ1
30
CZ1-1
FZ
5
FZ
4
26D2
52
C2
TM
(3MIN)
3
3
FZ0
FZ
3
CZ2
TM
CH1
FZ
2
51C2
1
26
L1
FZ0
CZ2
63
H2
CZ1
51C1
8
52 52
C1 C2
CH2
26D3
26D1
SW2
CZ1
52
C1
51F4
51F2
GL
Tr
AC
220 ~
240V
30
CZ2-2
30
CZ2-2
52
C2
FZ4
FZ7
TB4 12
Caution,
1.To protect each Fan motors and Compressors
from abnormal current,these Over current relays<51C1,2>,
<51F1~5>are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressors from frequently "ON-OFF",timer<TM>is
installed. Therefore,do not change factory set value of this timer.
3.This timer<2>installed so that two compressors may never start at
the same time. The unit stop if the set value of the timer is changed.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 33 -
Symbol
MC1·2
MF1
MF2·3
52C1·2
52F1
TB1~5
CH1·2
F
Tr1~3
51C1·2
51F1~5
63H1·2
26L1·2
TM
2
FZ0·1
CZ1·2
30CZ1-1, 2
30CZ2-1, 2
<SW1>
<SW2>
<GL>
<RL1·2>
<23WA>
26D1~4
52F2~7
FZ2~7
Name
C ompressor motor
Fan motor (indoor)
Fan motor (outdoor)
C ontactor (compressor)
C ontactor (fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
O ver current relay(compressor)
O ver current relay (fan I/D ,O/ D)
H igh-pressure sw itch
Thermostat(freeze protection)
Timer (anti short cycle)
Timer
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (check)
Auxiliary relay (check)
Sw itch (off)
Sw itch (on)
Lamp (operation)
Lamp (check)
Thermostat (room temp.)
Thermostat (ambiemt temp.)
C ontactor (fan O /D )
Auxiliary relay (fan O/D )
PR-5, 8, 10YC
(SPECIAL ORDER : K CONTROL & LOW TEMPERATURE)
Power supply
3Phase
380~415Volt
50Hertz
CIRCUIT BREAKER
(FIELD SUPPLY)
PR - 5YC ···40A
PR - 8YC ···50A
PR -10YC ···60A
L1
MC
TB1
Red
L2
L3
N
52C
Red
White
White
Black
Black
51C
Red
Black
51F2
Blue
PE
52F1
DSA
CN
1
3
Red
51F1
Black
R1
Red
S1
S1
White
T1
T1
Black
Red
White
Blue
TB2
R1
TB2
52F2
Red
White
Black
R2
R2
1
Red
S2
S2
2
White
T2
T2
3
Black
MF2
51F3
52F3
MF1
Black
Green/Yellow
Tr1
52F4
INTERNAL
PROTECTOR
F(3.15A)
TB3 11
11
TH2
51F3
30
CZ
IB
15
14
51F1
FZ1
51F2
A
B
C
D TB4
26D3
FZ
2
FZ
2
63H
FZ1
CZ
FZ
3
FZ
4
52
F1
Tr2
51C
26D4
52
F2
FZ2
TH5
52
F3
CZ
52C
52
F4
FZ1
FZ3
CH
30
CZ
R/C
52C
FZ
3
30
CZ
8,10YC ONLY
FZ4
12
TB3 12
Caution,
To protect each Fan motors and Compressor from abnormal current,
these Over current relays<51C>,<51F1,2,3>are installed.
Therefore,do not change factory set value of these Over current relays.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 34 -
Symbol
MC
MF1
MF2
52C
52F1
TB1~4
CH
F
Tr1·2
51C
51F1,2,3
63H
FZ1
CZ
30CZ
IB
TH2
52F2~4
FZ2~4
TH5
R/C
DSA
Name
C ompressor motor
Fan motor(indoor)
Fan motor(outdoor)
C ontactor(compressor)
C ontactor(fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
(compressor)
O ver current relay
Over current relay(fanI/D ,O /D )
H igh-pressure sw itch
Auxiliary relay(fan)
Auxiliary relay(compressor)
Auxiliary relay(check)
Indoor board
Thermistor(pipe)
C ontactor(fan O /D )
Auxiliary relay(fan O/D )
Thermistor(room temp)
R emote controller
Surge absorber circuit board
INTERNAL
PROTECTOR
PRH-5, 8, 10YA
PRH-5, 8, 10YA-L (STANDARD)
CIRCUIT BREAKER
Power Supply
3Phase
(FIELD SUPPLY)
PRH- 5YA, ···40A
PRH- 5YA-L
PRH- 8YA, ···50A
PRH- 8YA-L
PRH-10YA, ···60A
PRH-10YA-L
380~415Volt
50Hertz
TB1
L1
L3
51C
52C
RED
RED
L2
WHITE
BLACK
BLACK
BLACK
N
51F2
RED
WHITE
BLUE
R1
PE
TB2
S1
BLACK
T1
52F
TB2
RED
R2
WHITE
S2
BLACK
T2
51F1
X1
WHITE
TB3
1
2
3
RED
WHITE
F
(3.15A)
MF1
INTERNAL
PROTECTOR
BLACK
11
11
TB4
1
SWITCH BOX
(FIELD SUPPLY)
15
HZ
HZ
13
51F1
F
(3.15A)
SW2
SW1
COOL
HEAT
14
RL
GL
51F2
FZ1
52C
C
H
Tr
AC
220~
240V
MF2
BLACK
RED
RED
F
X1
63H
SW3
23
WA
26
D2
51 C
AC
24V
1
3
2
TB4
4
5
6
21
S4
7
26L
CZ
CZ
CH
52F
CZ
HZ
3
FZ0
26
D1
FZ1
TM
8,10YA,
YA-L
ONLY
(3MIN)
30
CZ
FZ0
FZ1
8
TB3
INTERNAL
PROTECTOR
MC
RED
WHITE
WHITE
52C
X1
X2
X2
30
CZ
TM
30
CZ
52C
12 TB3
12
Caution,
1.To protect each Fan motors and Compressors from abnormal current,
these Over current relays<51C>,<51F1,2>are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressor from frequently "ON-OFF" ,timer<TM>is
installed. Therefore,do not change factory set value of this timer.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 35 -
Symbol
MC
MF1
MF2
52C
52F
TB1~4
CH
F
Tr
51C
51F1, 2
63H
26L
26D1·2
TM
21S4
FZ0·1
CZ
HZ
30CZ
X1·2
<SW1>
<SW2>
<SW3>
<GL>
<RL>
<23WA>
Name
Compressor motor
Fan motor (in door)
Fan motor (out door)
Contactor (compressor)
Contactor (fan I/D)
Terminal block
Crankcase heater
Fuse
Transformer
O v e r c u r r e n t r e l a y ( compressor)
O v e r c u r r e n t r e l a y (fan I/D,O/D)
High-pressure switch
Thermostat(freeze protection)
Thermostat (defrost)
Timer (anti short cycle)
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (heater)
Auxiliary relay (check)
Auxiliary relay (defrost)
Switch (operation mode)
Switch (off)
Switch (on)
Lamp (operation)
Lamp (check)
Thermostat (room temp.)
PRH-15, 20YA
PRH-15, 20YA-L (STANDARD)
CIRCUIT BREAKER
(FIELD SUPPLY)
PRH-15YA
···100A
PRH-15YA-L
PRH-20YA ···125A
PRH-20YA-L
Power supply
3Phase
380~415Volt
50Herts
TB1
L1
Red
MC1
52C1
Red
L2
White
White
L3
Black
Black
51C1
INTERNAL
PROTECTOR
Red
Black
51F2
Red
N
Blue
White
Black
52C2
Red
51C2
Red
Black
MC2
Red
MF2
INTERNAL
PROTECTOR
White
White
Black
Black
Black
51F3
51F1
52F
Red
Red
White
INTERNAL
PROTECTOR
Red
TB3
X2
R 21
R 22
1
Red
White
S
22
2
White
Black
T 21
T 22
3
Black
S
21
MF3
INTERNAL
PROTECTOR
MF1
Black
F
TB2
X1 1
R 11
R 12
Red
2 White
S 11
S 12
3 Black
T 11
T 12
Red
White
F(3.15A)
TB4 11
TB5
SWITCH BOX
(FIELD SUPPLY)
1
51F1
FZ0
HZ
HZ
F
30
CZ1-2
SW1
(3.15A)
RL1
HEAT
COOL
RL2
SW2
14
30
CZ2-2
TB4
13
GL
C H C H
Tr
AC
220~
240V
52
C2
High
51F2
CZ1
AC
24V
TB5
2
3
4
5
6
8
7
CZ2
63
H1
HZ
1
26
L1
FZ0
CZ2
CH2
63
H2
CZ1
51
C1
9
52 52
C1 C2
CZ1
52
C1
51F3
SW3
Low
23WA
52
F
X1
51
C2
TM
(3MIN)
52
C1
1
26
L2
21
S41
(3MIN)
30
CZ2-1
FZ0
52
C1
30
CZ1
30
CZ1-1
TB4 12
Caution,
1.To protect each Fan motors and Compressors from abnormal current,
these Over current relays<51C1,2>,<51F1,2,3>are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressors from frequently "ON-OFF" ,timer<TM>is
installed. Therefore,do not change factory set value of this timer.
3.This timer<2>installed so that two compressors may never start at
the same time. The unit stop if the set value of the timer is changed.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 36 -
30
CZ2-1
30
CZ1-2
Symbol
MC1·2
MF1
MF2·3
52C1·2
52F
TB1~5
CH1·2
F
Tr
51C1·2
51F1~3
63H1·2
26L1·2
26D1~4
TM
2
21S41·42
FZ0·1
CZ1·2
HZ
30CZ1-1,2
30CZ2-1,2
X1~4
<SW1>
<SW2>
<SW3>
<GL>
<RL1·2>
<23WA>
X3
21
S42
26
D2
2
(2SEC)
30
CZ2
2
FZ1
10
26
D4
26
D3
26
D1
FZ1
TM
30
CZ1-1
X2
52
C2
TM
3
3
FZ1
CH1
X2
CZ2
30
CZ2-2
52
C2
X4
X2
X1
X4
X3
TB4 12
Name
C ompressor motor
Fan motor (in door)
Fan motor (out door)
C ontactor (compressor)
C ontactor (fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
O ver current relay(compressor)
O ver current relay (fan I/D ,O/D )
H igh-pressure sw itch
Thermostat(freeze protection)
Thermostat (defrost)
Timer (anti short cycle)
Timer
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (heater)
Auxiliary relay (check)
Auxiliary relay (check)
Auxiliary relay (defrost)
Sw itch (operation mode)
Sw itch (off)
Sw itch (on)
Lamp (operation)
Lamp (check)
Thermostat (room temp.)
PRH-5, 8, 10YA
PRH-5, 8, 10YA-L
(SPECIAL ORDER : K CONTROL)
CIRCUIT BREAKER
(FIELD SUPPLY)
PRH- 5YA, ···40A
PRH- 5YA-L
PRH- 8YA,
PRH- 8YA-L···50A
PRH-10YA,
PRH-10YA-L···60A
Power supply
3Phase
380~415Volt
50Herts
TB1
L1
Red
MC
51C
52C
Red
L2
White
White
L3
Black
Black
Red
Black
51F2
N
Blue
PE
52F
DSA
CN
1
3
Red
51F1
Black
Black
TB2
X1
1
Red
S1
S2
2
White
T1
T2
3
Black
R1
R2
MF2
Red
White
Blue
INTERNAL
PROTECTOR
MF1
Green/Yellow
INTERNAL
PROTECTOR
F(3.15A)
TB3 11
11
TH2
15
HZ
30
CZ
IB
FZ
HZ
51F1
13
51F2
X1
A
B
C
63H
D TB4
HZ
CZ
52F
FZ
51
CM
21
S4
26
D2
Tr
TH5
CZ
52C
26
D1
X2
FZ
X1
CH
30
CZ
R/C
52C
X2
30
CZ
8,10YA,YA-L ONLY
TB3 12
TB3 12
Caution,
To protect each Fan motors and Compressor from abnormal current,
these Over current relays<51C>,<51F1,2>are installed.
Therefore,do not change factory set value of these Over current
relays.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 37 -
Symbol
MC
MF1
MF2
52C
52F
TB1~4
CH
F
Tr
51C
51F1,2
63H
26D1·2
21S4
FZ
CZ
HZ
30CZ
X1·2
IB
TH2
TH5
R/C
DSA
Name
C ompressor motor
Fan motor(indoor)
Fan motor(outdoor)
C ontactor(compressor)
C ontactor(fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
O ver current relay(compressor)
O ver current relay(fanI/D ,O/D )
H igh-pressure sw itch
Thermostat(defrost)
4-Way valve
Auxiliary relay(fan)
Auxiliary relay(compressor)
Auxiliary relay(heater)
Auxiliary relay(check)
Auxiliary relay(defrost)
Indoor board
Thermistor(pipe)
Thermistor(room temp.)
R emote controller
Surge absorber circuit board
14
PRH-5, 8, 10YA
PRH-5, 8, 10YA-L
(SPECIAL ORDER : LOW TEMPERATURE)
CIRCUIT BREAKER
(FIELD SUPPLY)
PRH- 5YA, ···40A
PRH- 5YA-L
PRH- 8YA, ···50A
PRH- 8YA-L
PRH-10YA, ···60A
PRH-10YA-L
Power supply
3Phase
380~415Volt
50Herts
TB1
L1
Red
MC
52C
L2
White
L3
Black
N
51C
Red
Red
White
Black
Black
51F2
TB2
R1
R1
Blue
PE
52F1
51F1
Red
S1
White
T1
T1
Black
Red
R2
R2
1
Red
S2
S2
2
White
T2
T2
3
Black
White
Black
51F3
Red
X1
TB2
52F2
Red
S1
MF2
52F3
White
MF1
Black
Black
Tr1
52F4
INTERNAL
PROTECTOR
F(3.15A)
TB3 11
11
51F3
TB4
1
SWITCH BOX
(FIELD SUPPLY)
HZ
15
HZ
14
F
(3.15A)
51F1
SW1
COOL
RL
HEAT
SW2
FZ1
51F2
GL
C
AC
220~
240V
H
63H
AC
24V
2
26D3
X1
SW3
23WA
Tr2
3
4
16
TB313
5
6
7
TB4
51C
52
F1
FZ
2
FZ
2
21
S4
26
D2
26D4
CZ
HZ
52C
26
D1
26L
FZ0
TM
(3MIN)
CZ
3
CZ
30
CZ
FZ1
FZ0
FZ3
X2
FZ
3
52C
TM
FZ4
30
CZ
8
8,10YA,
YA-L ONLY
52
F4
52
F3
X2
52
C
X1
FZ1
30
CH
FZ
4
52
F2
FZ2
CZ
1
FZ
3
12
TB3 12
Caution,
1.To protect each Fan motors and Compressor from abnormal current,
these Over current relays<51C>,<51F1,2,3>are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressor from frequently "ON-OFF",timer<TM>is
installed. Therefore,do not change factory set value of this timer.
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 38 -
Symbol
MC
MF1
MF2
52C
52F1
TB1~4
CH
F
Tr1·2
51C
51F1,2,3
63H
26L
26D1~4
TM
21S4
FZ0,1
CZ
HZ
30CZ
X1·2
<SW1>
<SW2>
<SW3>
<GL>
<RL>
<23WA>
52F2~4
FZ2~4
Name
C ompressor motor
Fan motor (indoor)
Fan motor (outdoor)
C ontactor (compressor)
C ontactor (fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
O ver current relay(compressor)
O ver current relay(fanI/D ,O/D )
H igh-pressure sw itch
Thermostat(freeze protection)
Thermostat (defrost)
Timer (anti short cycle)
4-Way valve
Auxiliary relay (fan)
Auxiliary relay (compressor)
Auxiliary relay (heater)
Auxiliary relay (check)
Auxiliary relay (defrost)
Sw itch (operatin mode)
Sw itch (off)
Sw itch (on)
Lamp (operation)
Lamp (check)
Thermostat (room temp.)
C ontactor (fan O /D )
Auxiliary relay (fan O/D )
INTERNAL
PROTECTOR
PRH-15, 20YA
PRH-15, 20YA-L
(SPECIAL ORDER : LOW TEMPERATURE)
CIRCUIT BREAKER
(FIELD SUPPLY)
PRH-15YA ···100A
PRH-15YA-L
PRH-20YA ···125A
PRH-20YA -L
Power supply
3Phase
380~415Volt
50Herts
TB1
L1
Red
MC1
52C1
Red
L2
White
White
L3
Black
Black
51C1
INTERNAL
PROTECTOR
Red
Black
51F2
Red
N
Blue
White
Black
PE
52C2
Red
51C2
Red
MC2
Red
Red
S 11
S 11
White
T 11
T 11
Black
INTERNAL
PROTECTOR
TB2
52F2
Red
White
51F4
52F3
Black
R 12
S 12
T 12
R 12 X1 1 Red
2 White
S 12
3 Black
T 12
MF2
White
White
Black
Black
Black
51F3
TB3
R 21 R 21
S 21 S 21
White
T 21
Black
T 21
TB3
52F5
Red
Red
White
51F1
52F
Red
Red
White
1
Red
S 22
S
22
2
White
T 22
T 22
3
Black
MF3
INTERNAL
PROTECTOR
52F7
Tr2
MF1
Black
R 22 X2
INTERNAL
PROTECTOR
52F4
Tr1
R 22
Black
51F5
52F6
F
TB2
R 11 R 11
F(3.15A)
TB4 11
TB5
SWITCH BOX
(FIELD SUPPLY)
1
HZ
51F1
FZ0
HZ
TB4 14
18
F
30
CZ1-2
SW1
(3.15A)
RL1
HEAT
COOL
RL2
SW2
30
CZ2-2
51F4
51F5
51F2
51F3
TB4 13
GL
Tr
AC
220~
240V
52
C2
High
23WA
CZ2
CZ1
2
3
4
5
6
8
7
9
52 52
C1 C2
CZ1
52
C1
SW3
Low
AC
24V
TB5
HZ
63
H1
63
H2
CZ1
51
C1
1
26
L1
FZ0
CZ2
CH2
52
F
TM
(3MIN)
52
C1
1
26
L2
CH1
30
CZ2-1
21
S41
(3MIN)
26
D1
FZ1
52
C1
30
CZ1
10
30
CZ1-1
30
CZ1-2
X3
2
(2SEC)
30
CZ2
2
FZ1
12
30
CZ2-1
FZ
2
X2
26
D3
52
C2
TM
3
3
FZ0
X2
FZ
2
FZ
3
FZ
5
FZ
4
30
CZ2-2
26
D4
21
S42
26
D2
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 39 -
FZ
6
FZ
7
52
F2
52
F4
FZ
3
Symbol
FZ
6
X4
FZ4
Name
C om pressor m otor
Fan m otor (indoor)
Fan m otor (outdoor)
C ontactor (com pressor)
C ontactor (fan I/D )
Term inal block
C rankcase heater
Fuse
Transform er
Over current relay(com pres s o r)
Over current relay (fan I/D ,O / D )
H igh-pressure sw itch
Therm ostat(freeze protectio n )
Therm ostat (defrost)
Tim er (anti short cycle)
Timer
4-W ay valve
Auxiliary relay (fan)
Auxiliary relay (com pressor)
Auxiliary relay (heater)
Auxiliary relay (check)
Auxiliary relay (check)
Auxiliary relay (defrost)
Sw itch (operation m ode)
Sw itch (off)
Sw itch (on)
Lam p (operation)
Lam p (check)
Therm ostat (room tem p.)
Therm ostat (am biem t tem p. )
Contactor (fan O/D)
Auxiliary relay (fan O/D)
52
F7
52
F6
FZ6
FZ3
X3
MC1·2
MF1
MF2·3
52C1·2
52F1
TB1~5
CH1·2
F
Tr1~3
51C1·2
51F1~5
63H1·2
26L1·2
26D1~4
TM
2
21S41·42
FZ0·1
CZ1·2
HZ
30CZ1-1, 2
30CZ2-1, 2
X1~4
<SW1>
<SW2>
<SW3>
<GL>
<RL1·2>
<23WA>
26D1~4
52F2~7
FZ2~7
52
F5
FZ5
52
F3
X4
X2
X1
52
C2
26D4
26D2
FZ2
TB4 12
Caution,
1.To protect each Fan motors and Compressors
from abnormal current,these Over current relays<51C1,2>,
<51F1~5>are installed.
Therefore,do not change factory set value of these Over current relays.
2.To protect the compressors from frequently "ON-OFF",timer<TM>is
installed. Therefore,do not change factory set value of this timer.
3.This timer<2>installed so that two compressors may never start at
the same time. The unit stop if the set value of the timer is changed.
FZ
5
CZ2
51
C2
FZ1
TB4
X1
TM
30
CZ1-1
26D3
26D1
C H C H
FZ7
PRH-5, 8, 10YA
PRH-5, 8, 10YA-L
(SPECIAL ORDER : K CONTROL & LOW TEMPERATURE)
CIRCUIT BREAKER
(FIELD SUPPLY)
PRH- 5YA, ···40A
PRH- 5YA-L
PRH- 8YA, ···50A
PRH- 8YA-L
PRH- 10YA ···60A
PRH-10YA-L
Power supply
3Phase
380~415Volt
50Hertz
L1
MC
TB1
Red
L2
L3
N
52C
51C
Red
White
White
Black
Black
Red
Black
51F2
Blue
PE
52F1
DSA
CN
1
3
51F1
Red
TB2
R1
R1
Red
S1
S1
White
T1
T1
Black
Red
White
Blue
INTERNAL
PROTECTOR
TB2
52F2
Red
White
Black
X1
R2
R2
1
Red
S2
S2
2
White
T2
T2
3
Black
MF2
51F3
52F3
MF1
Black
Black
Green/Yellow
Tr1
52F4
INTERNAL
PROTECTOR
F(3.15A)
TB3 11
11
TH2
51F3
HZ
HZ
30
CZ
IB
15
14
16
TB3 13
51F1
FZ1
51F2
26D3
X1
A
B
C
D TB4
FZ1
CZ
52
F1
21
S4
Tr2
FZ
2
FZ
2
63H
HZ
26
D2
51 C
26D4
CZ
52C
26
D1
FZ
4
52
F2
FZ2
TH5
FZ
3
52
F4
52
F3
X2
FZ1
FZ3
X1
CH
30
CZ
R/C
52C
X2
FZ
3
30
CZ
8,10YA,YA-L ONLY
FZ4
12
TB3 12
Caution,
To protect each Fan motors and Compressor from abnormal current,
these Over current relays<51C>,<51F1,2,3>are installed.
Therefore,do not change factory set value of these Over current relays.
Symbol
MC
MF1
MF2
52C
52F1
TB1~4
CH
F
Tr1·2
51C
51F1,2,3
63H
26D1~4
21S4
FZ1
CZ
HZ
30CZ
X1·2
IB
TH2
52F2~4
FZ2~4
TH5
R/C
DSA
Note:
1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts.
3.Color of earth wire is yellow and green twisting.
4.Not specified color of wire is brown.
5.Specification subject to change without notice.
- 40 -
Name
C ompressor motor
Fan motor(indoor)
Fan motor(outdoor)
C ontactor(compressor)
C ontactor(fan I/D )
Terminal block
C rankcase heater
Fuse
Transformer
(compressor)
Over current relay
O ver current relay(fanI/D ,O/D )
H igh-pressure sw itch
Thermostat(defrost)
4-Way valve
Auxiliary relay(fan)
Auxiliary relay(compressor)
Auxiliary relay(heater)
Auxiliary relay(check)
Auxiliary relay(defrost)
Indoor board
Thermistor(pipe)
C ontactor(fan O/D )
Auxiliary relay(fan O /D )
Thermistor(room temp)
R emote controller
Surge absorber circuit board
ELECTRICAL OPERATION FLOW CHARTS
PR-5, 8, 10YC
START
POWER ON
CH ON
GL
ON
30CZ ON (SELF HOLD)
SW2
NO
ON?
YES
FZ0,1 ON (SELF HOLD)
52F ON
MF1 OPERATE
YES
NO
23WA ON?
YES
CZ
ON
TM ON
PASS THE 3 MIN.?
NO
YES
52C ON
MC OPERATE
MF2 OPERATE
CH
OFF
SAFETY
DEVICE OFF?
YES
30CZ
OFF
52C OFF
MC STOP
MF2 STOP
RL
ON
CH ON
SERVICE CALL
- 41 -
NO
PRH-5, 8, 10YA
PRH-5, 8, 10YA-L
START
POWER ON
CH ON
GL ON
30CZ ON (SELF HOLD)
SW3 ON?
NO
YES
FZ0,1 ON (SELF HOLD)
52F ON
MF1 OPERATE
SW1 COOL?
NO
HZ ON
YES
23WA ON?
21S4 ON
NO
NO
23WA ON?
YES
CZ ON
YES
CZ ON
TM ON
TM ON
PASS THE 3 MIN.?
NO
NO
PASS THE 3 MIN.?
YES
YES
52C ON
MC OPERATE
MF2 OPERATE
52C ON
MC OPERATE
MF2 OPERATE
CH OFF
CH OFF
SAFETY
DEVICE OFF?
NO
NO
YES
30CZ OFF
CONDENSING
TEMP. <
= -12˚C?
YES
26D1, 2 ON
52C OFF
MC STOP
MF2 STOP
X1 ON
X2 ON (SELF HOLD)
RL ON
21S4 OFF
MF2 STOP
CH ON
SERVICE CALL
NO
CONDENSING
TEMP. <
= 6˚C?
YES
26D1, 2 OFF
X1, 2 OFF
21S4 ON
MF2 OPERATE
- 42 -
PR-15, 20YC
START
POWER ON
CH1, 2 ON
GL ON
30CZ1, 30CZ2 ON (SELF HOLD)
NO
SW2 ON?
YES
FZ0, FZ1 ON (SELF HOLD)
52F ON
MF1 OPERATE
YES
NO
23WA No.1 ON?
YES
CZ1 ON
TM1 ON
NO
PASS THE 3 MIN.?
YES
52C1 ON
MC1 OPERATE
MF2 OPERATE
CH1 OFF
NO
23WA No.2 ON?
YES
CZ2 ON
TM2 ON
NO
PASS THE 2 SEC.?
YES
52C2 ON
MC2 OPERATE
MF3 OPERATE
CH2 OFF
No.2 SAFETY
DEVICE OFF?
No.1 SAFETY
DEVICE OFF?
NO
YES
30CZ2 OFF
YES
30CZ1 OFF
52C2 OFF
MC2 STOP
MF3 STOP
52C1 OFF
MC1 STOP
MF2 STOP
RL2 ON
RL1 ON
CH2 ON
CH1 ON
SERVICE CALL
- 43 -
NO
PRH-15, 20YA
PRH-15, 20YA-L
START
HZ ON
POWER ON
21S41, 2 ON
CH1, 2 ON
NO
23WA No.2 ON?
GL ON
YES
CZ1 ON
30CZ1, 30CZ2 ON (SELF HOLD)
SW3 ON?
TM1 ON
NO
NO
YES
FZ0, FZ1 ON (SELF HOLD)
PASS THE 3 MIN.?
YES
52F ON
MF1 OPERATE
SW1 COOL?
TM2 ON
NO
NO
PASS THE 2 SEC.?
YES
YES
23WA No.1 ON?
52C2 ON
MC2 OPERATE
MF3 OPERATE
NO
YES
CH2 OFF
CZ1 ON
TM1 ON
PASS THE 3 MIN.?
NO
23WA No.1 ON?
YES
NO
52C1 ON
MC1 OPERATE
MF2 OPERATE
YES
52C1 ON
MC1 OPERATE
MF2 OPERATE
CH1 OFF
CH1 OFF
NO
23WA No.2 ON?
No.1 CONDENSING
TEMP. <
= -12˚C?
NO
YES
26D1, 3 ON
YES
CZ2 ON
X1 ON
X3 ON (SELF HOLD)
TM2 ON
PASS THE 2 SEC.?
No.2 CONDENSING
TEMP. <
= -12˚C?
21S41 OFF
MF2 STOP
NO
YES
26D2, 4 ON
YES
No.1 CONDENSING
TEMP. <
= 6˚C?
52C2 ON
MC2 OPERATE
MF3 OPERATE
YES
26D1, 3 OFF
CH2 OFF
No.2 SAFETY
DEVICE OFF?
No.1 SAFETY
DEVICE OFF?
YES
30CZ1 OFF
52C1 OFF
MC1 STOP
MF2 STOP
NO
X2 ON
X4 ON (SELF HOLD)
21S42 OFF
MF3 STOP
NO
X1, 3 OFF
NO
YES
30CZ2 OFF
21S41 ON
MF2 OPERATE
52C2 OFF
MC2 STOP
MF3 STOP
No.2 CONDENSING
TEMP. <
= 6˚C?
NO
CH2 ON
CH1 ON
SERVICE CALL
21S42 ON
MF2 OPERATE
- 44 -
NO
YES
No.1 DEFROST
OPERATION?
RL2 ON
RL1 ON
NO
YES
REFRIGERANT SCHEMATICS
PR-5YC
Condenser
Evaporator
ø19.05
High
pressure
switch
Check
joint
ø19.05
Check
joint
Pressure
gauge
ø12.7
Check
joint
ø22.2
Check
joint
Compressor
Capillary
Tube
ø12.7
ø12.7
Strainer
Dryer
: OPTION
Notes: This schematics shows one refrigerant cycle.
PR-15,20YC or PRH-15,20YA or PRH-15,20YA-L is
composed of two refrigerant cycles.
PR-8, 10, 15, 20YC
Condenser
Evaporator
ø19.05
High
pressure
switch
Check
joint
ø19.05
Check
joint
ø12.7
Pressure
gauge
Check
joint
ø22.2
Compressor
Check
joint
Capillary
Tube
ø12.7
ø12.7
Strainer
: OPTION
- 45 -
Dryer
PRH-5YA
Condenser
Evaporator
ø19.05
High
pressure
switch
Check
joint
4-Way
valve
Check
joint
ø19.05
Pressure
gauge
ø12.7
Check
joint
ø22.2
Check
joint
Compressor
Capillary
Tube
Capillary
Tube
ø12.7
ø12.7
Strainer
Check
valve
Strainer
Dryer
: OPTION
PRH-8, 10, 15, 20YA
Notes: This schematics shows one refrigerant cycle.
PR-15,20YC or PRH-15,20YA or PRH-15,20YA-L is
composed of two refrigerant cycles.
Condenser
Evaporator
8, 15YA: ø22.0
10, 20YA: ø25.4
High
pressure
switch
4-Way
valve
Check
joint
ø15.88
Muffler ø15.88
8, 15YA: ø22.0
10, 20YA: ø25.4
Pressure
gauge
Check
joint
Check
joint
ø25.4
Compressor
Check
joint
Capillary
Tube
ø12.7
Strainer
Capillary
Tube
ø12.7
Check
valve
: OPTION
- 46 -
Strainer
Dryer
PRH-5YA-L
Condenser
Evaporator
ø19.05
High
pressure
switch
Check
joint
4-Way
valve
Check
joint
ø19.05
Pressure
gauge
ø12.7
Check
joint
ø22.2
Check
joint
Compressor
Capillary
Tube
ø12.7
Accumulator
Capillary
Tube
ø12.7
Strainer
Check
valve
Strainer
Dryer
: OPTION
PRH-8, 10,15,20YA-L
Notes: This schematics shows one refrigerant cycle.
PR-15,20YC or PRH-15,20YA or PRH-15,20YA-L is
composed of two refrigerant cycles.
Condenser
Evaporator
8,15YA-L: ø22.0
10,20YA-L: ø25.4
High
pressure
switch
4-Way
valve
Check
joint
ø15.88
Muffler ø15.88
8,15YA-L: ø22.0
10,20YA-L: ø25.4
Pressure
gauge
Check
joint
Check
joint
ø25.4
Compressor
Check
joint
Capillary
Tube
ø12.7
Strainer
Accumulator
Capillary
Tube
ø12.7
Check
valve
: OPTION
- 47 -
Strainer
Dryer
SAFETY & CONTROL DEVICES
ITEM
NO.
COMPRESSOR OVER CURRENT RELAY
COMPRESSOR INTERNAL THERMOSTAT
HIGH PRESSURE SWITCH
FREEZE PROTECTOR
FROST PROTECTOR (ONLY PRH-YA,PRH-YA-L)
INDOOR FAN MOTOR OVER CURRENT RELAY
OUTDOOR FAN MOTOR OVER CURRENT RELAY
OUTDOOR FAN MOTOR INTERNAL THERMOSTAT
FUSE (CONTROL CIRCUIT)
FUSE (OPERATION CIRCUIT)
51C
63H
26L
26D1,2
51F1
51F2
F
F
OUTDOOR FAN MOTOR OVER CURRENT RELAY
(USE THE OPTIONAL PARTS : LOW AMBIENT PARTS)
PR-8YC
PRH-8YA
PRH-8YA-L
26.0A
110˚C OFF
27.5A
120˚C OFF
2.94MPa OFF
-2˚C IN
-12˚C IN, 6˚C OUT
3.2A
2.0A
150˚C OFF
3.15A
3.15A
2.3A
51F3
ITEM
COMPRESSOR OVER CURRENT RELAY
COMPRESSOR INTERNAL THERMOSTAT
HIGH PRESSURE SWITCH
FREEZE PROTECTOR
FROST PROTECTOR (ONLY PRH-YA,PRH-YA-L)
INDOOR FAN MOTOR OVER CURRENT RELAY
OUTDOOR FAN MOTOR OVER CURRENT RELAY
OUTDOOR FAN MOTOR INTERNAL THERMOSTAT
FUSE (CONTROL CIRCUIT)
FUSE (OPERATION CIRCUIT)
PR-10YC
PRH-10YA
PRH-10YA-L
31.0A
130˚C OFF
3.6A
2.0A
PR-15YC
PRH-15YA
PRH-15YA-L
NO.
OUTDOOR FAN MOTOR OVER CURRENT RELAY
(USE THE OPTIONAL PARTS : LOW AMBIENT PARTS)
PR-5YC
PRH-5YA
PRH-5YA-L
PR-20YC
PRH-20YA
PRH-20YA-L
51C1,2
63H1,2
26L1,2
26D1,2,3,4
51F1
51F2,3
F
F
27.5A
31.0A
130˚C OFF
120˚C OFF
2.94MPa OFF
-2˚C IN
-12˚C IN, 6˚COUT
5.0A
6.6A
2.0A
150˚C OFF
3.15A
3.15A
51F4,5
2.0A
ACCESSORY AVAILABILITY
DESCRIPTION
MODEL NAME
PR- YC-K
PRH- YA-K
K-Remote controller
PRH- YA-LK
PR- YC
Low temperature cooling PRH- YA
PRH- YA-L
PR- YC
PRH- YA
Pressure gauge
PRH- YA-L
PR- YC
PRH- YA
Fin guard
PRH- YA-L
DESCRIPTION
MODEL NAME
PR- YC
Low temperature cooling
PRH- YA
PRH- YA-L
PR- YC
Pressure gauge
PRH- YA
PRH- YA-L
PR- YC
Fin guard
PRH- YA
PRH- YA-L
PR-5YC
PAC-201LC
PAC001PG
PAC101FG
-
PAC-201LC
PAC001PG
PAC101FG
PARTS CODE
PRH-8YA
PRH-8YA-L
PAC-202LC
PAC-202LC
PAC-202LC
PAC002PG
PAC002PG
PAC002PG
PAC102FG
PAC102FG
PAC102FG
PRH-15YA
PAC-201LCX2(PCS)
PAC001PGX2(PCS)
PAC104FG
-
PARTS CODE
PRH-15YA-L
PR-20YC
PAC-201LCX2(PCS)
PAC-201LCX2(PCS)
PAC001PGX2(PCS)
PAC001PGX2(PCS)
PAC105FG
PAC104FG
-
PRH-5YA
-
PRH-5YA-L
-
PAC-201LC
PAC001PG
PAC101FG
-
PR-15YC
PAC-201LCX2(PCS)
PAC001PGX2(PCS)
PAC104FG
-
:Factory install
:Field install
- 48 -
PR-8YC
PR-10YC
PAC-203LC
PAC003PG
PAC103FG
-
PRH-10YA
PAC-203LC
PAC003PG
PAC103FG
-
PRH-20YA
PAC-201LCX2(PCS)
PAC001PGX2(PCS)
PAC105FG
-
PRH-10YA-L
PAC-203LC
PAC003PG
PAC103FG
PRH-20YA-L
PAC-201LCX2(PCS)
PAC001PGX2(PCS)
PAC105FG
PHYSICAL DATA
[PRODUCT]
Product type
Product number : Cooling type
Product number : Heat pump
Product number : Heat pump
Capacity
kw
Cooling capacity (AS1861)
kW
Sensible Cooling capacity (AS1861)
kW
Cooling power consumption (Input)
kW
ByPass Factor
Heating capacity (AS1861) (Only PRH-YA,PRH-YA-L)
kW
Heating power consumption (Only PRH-YA,PRH-YA-L)
kW
ROOFTOP AIR-COOLED HEATPUMP PACKAGED AIR CONDITIONERS
PR,PRH,PRH-L SERIES
PR-5YC
PR-8YC
PR-10YC
PR-15YC
PR-20YC
PRH-5YA
PRH-8YA
PRH-10YA
PRH-15YA
PRH-20YA
PRH-5YA-L
PRH-8YA-L
PRH-10YA-L
PRH-15YA-L
PRH-20YA-L
17.6
28.1
35.2
52.8
70.3
16.3
23.8
29.7
46.3
60.8
13
19.7
25.3
38.4
50.2
5.4
8.3
11.4
16.8
22.7
0.19
0.24
0.18
0.18
0.11
15.1
23
32
45.5
61.2
4.6
7
9.6
14.4
19.3
[ELECTRICAL]
Minimum voltage
Volts
Approx. starting current
Amps
62
87
415
50
3
415
240/24
415
380
100
Unit current (Nominal voltage and AS1861
maximum conditions)
Amps
12.8
20.6
25.7
37.9
50.9
HP
1.0
2.26
1,400
1.5
2.90
1,410
2
3.28
3
4.72
1,420
4
6.06
Design voltage
Cycles
Volts
Hz
Phases
Power supply
Volts
Control voltage
Volts
Maximum voltage
Volts
Fan motor hp
Fan motor current
Amps
Fan motor speed
rpm
115
135
[COMPRESSOR]
Make
CRNQ-0500-TFD
Model
Type
Quantity
Nominal motor hp
HP
Locked rotor current
Amps
Normal run current (AS1861)
Amps
Swept volume
cc/rev
Bore
mm
Stroke
mm
Speed
rpm
ml
2
2,070
watts
40
kg
3.6
1
4.6
1
1
0.53
3
26
800
1.7
512
1
2.0
512
1.95
1.95
10
13
Number of cylinders
Oil charge
1
5
59.5
7.65
101.92
49.78
26.19
Type of oil
Crankcase heater
COPELAND
QR90K1-TFD
QR12M1-TFD
QR90K1-TFD
QR12M1-TFD
HERMETIC LINE START (RECIPROCATING)
1
1
2
2
7.5
10
2✕7.5
2✕10
83.4
95.2
83.4
95.2
11.7
15.62
2✕11.74
2✕15.22
177.45
221.8
2✕177.45
2✕221.8
55.58
18.29
22.86
18.29
22.86
2,900
4
3,250
2✕3,250
Calumet R015 or Witco 3GS
70
2✕70
[REFRIGERATION SYSTEM]
Refrigerant
Refrigerant charge per circuit
Number of refrigerant controls
Refrigerant control
Reverse cycle valve (Only PRH-YA,PRH-YA-L)
Defrost system (Only PRH-YA,PRH-YA-L)
[EVAPORATOR]
Quantity
Face area
sq.m
Rows deep
Rows high
Finned length
mm
Face velocity
m/s
Fins per meter
Fin material thickness
3
26
mm
mm
Gauge of copper tube
mm
Number of circuits
- 49 -
2✕5.8
2
2
2
2✕0.65
4
26
3
30
2.4
512
0.12
Aluminium
1.95
9.52
0.35
17
2.2
473
2.4
512
2.11
1.95
11
15
1,046
mm
Tube diameter
1
2✕4.6
2
0.69
Fin material
Fins pitch
R22
5.8
1
Capillary tube
4-Way valve
Reverse cycle defrost
4
30
2✕850
[PRODUCT]
ROOFTOP PACKAGE AIR COOLED HEATPUMP AND COOLING ONLY UNITS
PRH SERIES
PRH-5YA
PRH-8YA
PRH-10YA
PRH-15YA
PRH-20YA
Product type
Product number : Heat pump
[INDOOR AIR CIRCUIT]
Diameter of blowers
mm
1
2
253
Width of blowers
mm
182
Number of blowers
2
Normal fan motor run current
Air quantity
kW
A
L/s
External static pressure
282
Beltdrive
1.5
3.28
1,660
mm ✕mm
Return air dimensions (h ✕ w)
[CONDENSER]
mm ✕mm
Quantity
sq.m
Rows deep
Rows high
Finned length
mm
Face velocity
m/s
Fins per meter
Fin material thickness
1.1
2.90
1,400
300 ✕850
410 ✕900
1
1.3
3
30
1,700
1.2
473
1
1.12
3
23
1
1.46
3
30
2
2✕1.07
3
30
2.8
473
2.1
473
0.12
Aluminium
2.9
473
2.3
473
2.11
2.11
2.11
2.11
11
11
2.11
9.52
0.35
15
11
14
1
600
-
1
1
2
2
0.15
1
0.6
650
1,583
0.35
1
1.3
1,920
mm
mm
Tube diameter
mm
Gauge of copper tube
mm
Number of circuits
3.0
6.06
3,160
200
428 ✕1,820
464 ✕1,879
300 ✕1,150
410 ✕1,200
Fin material
Fins pitch
2.2
4.72
2,800
100
Pa
Supply air dimensions (h ✕ w)
Face area
0.75
2.26
900
2
393
Blower drive
Fan motor output
2
2
2✕1.32
3
37
2✕1,400
[OUTDOOR AIR CIRCUIT]
Number of fans
Diameter of fans
mm
Pitch of fans
Fan drive
mm
Fan motor output
kw
Quantity
Normal fan motor run current
Fan motor speed
Air quantity
Amps
rpm
L/s
800
-
Direct drive
0.35
1
1.3
990
2✕0.35
2
2✕1.3
2✕0.35
2
2✕1.3
645
3,083
2✕3,083
1,300
1,200
1,990
1,840
[ENCLOSURE AND FRAME]
Dimension
height
mm
width
mm
depth
mm
1,000
1,000
1,600
Munsell 5Y8/1
1.2
25.4
Color
Panel thickness
mm
Condensate drain size
mm
Weight
kg
Sound power level
dbA
Sound pressure level
dbA
299
73
62
393
75
64
- 50 -
413
75
64
698
79
68
729
79
68
INSTALLATION
All series of air conditioners are designed for outdoor installations and are to be placed on a slab or
rooftop, however if the air conditioner is to be installed in a plant room application, please contact your
equipment supplier prior to installation.
Access for both service and installation must be provided to the compressors, control wiring and fans as
shown below.
1.Clearances
(1) Care must be taken to prevent recirculation of
the condenser air. To stabilize compressor
condensing pressures it is recommended that
wherever possible the condenser air inlet side
be faced away from prevailing winds.
(2) For rooftop installation, the type of mounting
base depends on the roof construction. A builtup roof may not support the weight of the unit
and so it may be necessary to support the unit
by adding structural members below it.
(3) The units are equipped with hoisting
plates for rigging and hoisting of the unit.
The hoisting plates are located in the base
of the unit.
When hoisting the unit with a crane,
spreader bars must be used to prevent
damage to side panels by the supporting
cables.
PR-15,20YC
PRH-15,20YA
PRH-15,20YA-L
PR-5 10YC
PRH-5~10YA
PRH-5~10YA-L
300mm(min. clearance)
Condenser inlet
300mm(min. clearance)
1,000mm(min. clearance)
Evaporator coil service
Condenser inlet
700mm(min. clearance)
Electrical
control circuit
1,000mm(min. clearance)
and compressor
Evaporator coil service
service
Electrical
control circuit
and compressor Condenser outlet
Condenser inlet
service
300mm(min.
300mm(min.
clearance)
clearance)
700mm(min. clearance)
300mm(min. clearance)
Condenser inlet
Condenser inlet
1,000mm(min. clearance) 300mm(min. clearance)
Evaporator coil service
1,500mm(min. clearance)
1,500mm(min. clearance)
Condenser outlet
Condenser outlet
2.Roof Mounting
(1) The figure shows the use of the roof curb available
for mounting these units.
(2) The curb should be sealed and fixed to the roof by
weather stripping. A suggested means of sealing
the unit and roof curb is shown below.
4-ø15roof mounting holes
Roof curb
6-ø15
Unit mounting holes
Unit
Seal with tar
Roof deck
Roof curb
- 51 -
3.Duct Work
(1) All series units are equipped with horizontal
supply and return air openings. Duct connection to
the unit should be made with duct flanges and
secured directly to the air openings with flexible
duct connectors to avoid normal noise transmission.
PRH unit
Vertical air
plenum
Plenum
divider
Insulation
(2) For vertical air supply, a field supply plenum should
be used.
The figure below shows the recommended method
for duct connection.
(3) To prevent air leakage, all duct seams should be
taped.
Ducts run in air spaces that are not air-conditioned
must be insulated and provided with a vapor barrier.
Ducts exposed to the outside must be
weatherproofed. For quiet operation, we
recommend that the insulation on the supply duct
be placed inside, lining the duct.
Roof curb
Roof curb
Roof line
Duct Singleduct
divider
Duct
Duct connection with a vertical air plenum
(4) Where ducts from the outside enter a building, the
duct openings in the building should be sealed with
weather stripping to prevent rain, duct, sand,etc.
from entering the building.
(5) Correctly sized filters must be fitted and there is no
provision within the unit, however the filters may be
installed in the return air.
(2) The drain pipe must be provided with a trap on the
outside of the unit and also installed at an incline for
proper drainage, as shown below.
(3) To prevent condensate formation and leakage,
provide the drain pipe with insulation to safeguard
against sweating.
(4) Upon completion of the piping work, check that there
is no leakage and that the water drains off properly.
- 52 -
>70mm
A=
>2C
B=
>2XE.S.P
C=
A
B
(1) A 1 FPT condensate drain fitting is provided. The
drain pipe can be led out at the right or left side.
Under standard specifications, it is led out at the left
side and the right side is covered.
C
4.Drain piping
Drain piping
The drain pipe
should extend
below this level.
Note:ESP=External Static Pressure
Drain trap
Drain trap for condensate
5.Electrical Wiring
Remove the panel on the right side (PR,PRH-5 10) or the rear side (PR,PRH-15,20) of the unit and
connect the units power supply wiring to the proper terminals in the control box, as shown below.
MODEL
INDOOR FAN MOTOR OUTPUT <kW>
2
<mm >
POWER SUPPLY
WIRING
2
<mm >
EARTH
<A>
MAIN SWITCH
PR-5YC
PRH-5YA
PRH-5YA-L
0.75
1.1
PR-8YC
PRH-8YA
PRH-8YA-L
1.1
1.5
PR-10YC
PRH-10YA
PRH-10YA-L
1.5
2.2
PR-15YC
PRH-15YA
PRH-15YA-L
2.2
3.0
5.5
5.5
5.5
5.5
40
50
8
8
60
22
22
100
PR-20YC
PRH-20YA
PRH-20YA-L
3.0
4.0
22
22
100
Std.
Control box
Terminal block
Terminal block
Control box
power supply
Wiring for PR,PRH-5 10(right side view)
power supply
Wiring for PR,PRH-15,20(rear view)
TN-NET SYSTEM (For European models only)
L1
L2
L3
N
PE
Note:
All electrical wiring must be comply with local electrical authority regulations.
6.Final Checks
After having installed the unit, check that:
(1) The unit is fixed securely.
(2) The unit is installed properly.
(3) The drain pipe is provided with a drain trap.
(4) The electrical wiring has been connected correctly and the terminal screws have been properly
tightened.
(5) The duct work has been performed correctly.
7.Trial Operation
(1) Before turning the unit on, measure the resistance between the terminals of the electrical parts and
ground with a 500V megger and check that the value is at least 1MΩ. If the measured value is below 1MΩ,
do not operate the unit.
(2) Check the operation of the high pressure switch by activating it. Operation should stop when the two leads
of the outdoor unit fan motor are removed from the contactor and cooling continues for 5~10min.
(3) Check that the indoor and outdoor fans are rotating in the proper direction.
(4) After having checked the above points, proceed with a trial operation of the unit.
- 53 -
INSTRUCTIONS FOR USE
1.CHECK POINTS FOR OPERATION
Check the following points before you operate your air conditioner.
(1) Check that there is nothing blocking the flow of air from the air outlet into the air inlet.
Indoor Unit
Outlet grille
Inlet grille
Ceiling
Ceiling
Obstacle blocking air inlet
Obstacle blocking air inlet
Outdoor Unit
Obstacle blocking air inlet
(2) Make sure the air conditioner is properly grounded by checking the ground terminal .
Ground
- 54 -
2.CAUTION FOR USE
Keep the following points in mind to safeguard against failures and breakdowns.
(1) This air conditioner does not restart within 3min.
after shut down.
(These models have a crankcase heater in the
compressor. If the air conditioner is shut down
for a short time, please do not turn the power
switch to OFF, but turn the operation switch to OFF.)
(2) If the air conditioner is shut down by a power failure,
set the operation switch to OFF. When the power is
restored, normal air conditioner operation can be
resumed.
(3) Do not stick rods or other objects through the air
outlet during operation since this may result in
equipment damage or personal injury.
3 Minutes
Shutdown
Operation
3.MAINTENANCE
For superior performance and lasting durability, please do not forget to conduct
proper and regular maintenance.
3.1 Cleaning the Air Filter
Clean the air filter about once a week with a neutral cleanser and leave it to dry in a shady location. Clean
more regularly if the air filter gets very dirty.
If the filter gets blocked, air will not be sucked in properly, and the cooling effect will deteriorate. Failure to
clean the air filter may result in equipment breakdown or malfunctions.
3.2 Cleaning panels
Clean dirt off front panel as follows.
Use a household neutral cleanser such as for
dishes or vegetables. Moisten a soft cloth with
the cleanser, then wipe lightly. Next,wipe three
or four times with another soft cloth moisten
with water. Finally, wipe off all the remaining
cleanser with a soft cloth.
Moisten a soft cloth with the alcohol, then wipe
off lightly. Isopropyl alcohol is sold at stores as
reagents in small quantities.
Fingermarks
Grease
Adhesive
Note:
Alcohol is highly combustible. Take extreme
care when handling. Also, do not use paint or
adhesive thinner.
Paste
Neutral
Cleanser
Isopropyl
alcohol
3.3 Cleaning the Outdoor Unit Heat Exchanger
If you use your air conditioner for prolonged periods,
the outdoor heat exchanger will become dirty, impairing
its function and reducing air conditioners performance.
Consult your equipment supplier or air conditioning
contractor on how to clean the heat exchanger.
Heat exchanger
Heat exchanger
- 55 -
4. PREPARING FOR OPERATION AFTER PROLONGED SHUTDOWN
When the usage season starts, proceed with the following before starting operation:
(1)Clean the air filter.
(2)Do not use the unit immediately. Turn the main power switch on for a period of 3 hours before restarting
cooling / heating operation. This allows the compressors to come up to the correct operation temperatures.
Failure to do this, could cause compressor failure.
5.PREPARING FOR PROLONGED SHUTDOWN
After the usage season is over, prepare the air conditioner for later use by:
(1)Setting the power switch to OFF.
(2)Consulting your Air conditioning specialist for detailed information.
6.TROUBLESHOOTING
If any trouble occurs, turn the operation (start or run) switch off immediately.
Symptom
Possible cause
Power failure.
Wait for power supply
recovery.
Blown fuse of power
source switch.
Contact your
Air conditioning specialist.
Excessively low power
source voltage.
Ask your electric power
company.
The set temperature of
thermostat is
• excessively high for
cooling.
• excessively low for
heating.
For temperature control,
• decrease the set
temperature at cooling.
• increase the set
temperature at heating.
The room temperature is
• excessively low for
cooling.
• excessively high for
heating.
Can not be operated as
it is out of temperature
control range.
Air outlet and inlet
are blocked.
Remove blocking matter.
The filter installed in
the field is clogged
with dust.
Clean it.
Windows and doors are
being opened.
Close them.
Air outlet and inlet
are blocked.
Remove blocking matter.
The set temperature of
thermostat is
• excessively high for
cooling.
• excessively low for
heating.
For temperature control,
• decrease the set
temperature at cooling.
• increase the set
temperature at heating.
Insufficient
refrigerant charge.
Contact your
Air conditioning specialist.
Both fan and compressor
do not run.
Fan runs but compressor
does not run.
Fan runs but stops
immediately.
Runs but without
cooling/heating.
Remedy
Note:
If the unit does not operate normally after troubleshooting, please contact your local equipment supplier or
air conditioning contractor.
- 56 -
SPECIFICATION GUIDELINES
Please supply and install a one piece, air to air reverse cycle air conditioning system.
The system shall be completely assembled, tested and have a complete refrigeration charge ready for
installation and operation from the factory.
The system shall operate at outdoor ambient temperatures as high as 46˚C.
The system shall have a total cooling capacity of
kW or greater with an indoor air quantity of
L/s at
˚C db and
˚C wb entering indoor coil temperature with a
˚C temperature
entering
the outdoor coil.
The system shall have a sensible heat capacity of
˚C.
kW or greater with a room db temperature of
The total heating capacity (without electric element heaters) shall be
kW or greater at
˚Cdb,
˚C wb outdoor air conditions, with
˚C of indoor air entering indoor coil at
˚C db. One
kW electric heater element (accessory) shall be furnished.
The compressors shall be a welded high efficiency hermetic type with internal vibration isolation and be
equipped with a crankcase heater.
Compressors shall be protected by a factory installed anti-cycle device and provide a 3 minute delay before
compressor can restart.
Coils shall be of non-ferrous construction with mechanically bonded aluminium plate fins. Outdoor coils
shall be made, of 9.52mm OD, 0.35mm thick seamless copper tubes mechanically bonded to 0.12mm thick
aluminium plate fins.
Coils with multiple stage refrigeration systems shall consist of independent circuits. Face area of the coil
M2. The coil shall be factory pressure and leak tested at 3,233 kPa pressure.
shall not be less than
M2.
The indoor coil face area shall be not less than
Multi-wing propeller type fans shall be fitted at the condenser and shall be dynamically balanced, to ensure
smooth airflow and shall discharge vertically and be direct driven by a weatherproof three phase squirrel
cage
kW induction motor.
The system shall be factory wired and all electrical wiring must comply with the Local wiring code. (Controls
and control wiring shall be supplied by the contractor). Compressors and fan motors shall have both internal
and current sensitive overload devices.
An automatic defrost control shall be included to accomplish defrosting (only if required) every
minutes for a period of
minutes.
A low voltage transformer (24V) shall be factory installed in the unit for an external control circuit.
High pressure switch (pre-set) shall be factory installed.
The enclosure shall be a single, enclosed, weatherproof casing constructed of phosphatised, zinc coated
steel with acrylic resin primer and ivory white baked enamel finish.
The unit shall be provided with hoisting plates for rigging and hoisting the unit. The hoisting plates shall be
located in the base of the unit.
The unit shall have a 25mm OD male drain connection provided. The drain pipe shall be accessible from
either the left or right side of the unit. A blanking cap shall be provided to cap the drain outlet not being
used.
The duct (field supply) shall be fully insulated with fiber glass insulation to prevent sweating and to minimize
sound.
Each unit shall have a drain pan of 1mm thick steel coated with epoxy resin enamel.
The enclosure shall have openings provided for power connections. Access for both service and installation
shall be provided to compressors, control wiring, filters, electric heaters (when fitted) and fans.
Side panels and top panels shall be removable for easy service access.
The unit maximum dimensions shall be : height:
mm, width:
mm and depth:
mm.
Due to continuous product development, these guidelines are subject to change.
- 57 -
MEMO
- 58 -
DATA BOOK
PR,PRH
MITSUBISHI ELECTRIC CORPORATION
HEAD OFFICE DENKI BLDG., MARUNOUCHI,TOKYO 100,TELEX J24532 CABLE MELCO TOKYO
Issuued in January. 1999 MEE98K036
Printed in Japan.
New publication effective Jan. 1999.
Specifications subject to change without notice.