Download DSP-226 User`s Manual - DAS Audio
Transcript
User’s Manual DSP-226 Antes de utilizar el equipo, lea la sección “Precauciones de seguridad” de este manual. Conserve este manual para futuras consultas. Before operating the device, please read the “Safety precautions” section of this manual. Retain this manual for future reference. IMPORTANT SAFETY INSTRUCTION Please read the basic protective measure as below before using. 1. Please read all the safety instruction before using the product. 2. This product must be earthed. If it should be malfunction or break down, grounding provides a path of least resistance for electric current to reduce risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and earthed in accordance with all local codes and ordinance. DANGER- Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. 3. To reduce the risk of injury, close supervision is necessary when the product is used near children. 4. Do not use this product near water-for example, near a bathtub, washbowl, kitchen sink, in wet basement or near a swimming pool or the lake. 5. This product may be capable of producing sound levels that cloud cause permanent hearing loss. Do not operate for a long period of time at high volume level or at a level that is uncomfortable. If you experience any hearing loss or ringing in the ears, you should consult an audiologist. 6. This product should be located so that its location or position does not interfere with its proper ventilation. 7. This product should be located away from heat sources such as radiators, heat registers or other products that produce heat. 8. The product should be connected to a power supply only of the type described on the operation instructions or as marked on the product. 9. This product may be equipped with a polarized line plug (one blade wider than the other). This is a safety feature. If you are unable to insert the plug into the outlet, contact an electrician to replace your obsolete outlet. Do not defeat the safety purpose of the plug. 10. The power-supply cord of the product should be unplugged from the outlet when left unused for a long period of time. When unplugging the power-supply cord, do not pull on the cord, but grasp it by the plug. 11. Care should be taken so that object do not fall and liquid are not spilled into the enclosure through opening. 12. The product should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged; or B. Objects have been fallen, or liquid has been spilled into the product; or C. The product has been exposed to rain; or D. The product does not appear to operate normally or exhibits a marked change in performance; or E. The product has been dropped or the enclosure damaged.. 13. Do not attempt to service the product beyond that described in the user-maintenance instructions. All other servicing should be referred to qualified service personnel. 14. WARNING- Do not place objects on the product's power cord or place it in a position where anyone could trip over, walk on or roll anything over it. Do not allow the product to rest on or to be installed over power cords of any type. Improper installations of this type create the possibility of fire hazard and/or personal injury. 15. The power-supply cord should be unplugged from the outlet when the products is completely power off from the electric power sources and electric networks . CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER ( OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL The lightning flash with arrowhead synbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclosure, that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operation and maintenace (servicing) instruction in the literature accompanying the appliance. <2000m Only use it below the altitude of 2000 m for safety application. Only use it in nontropical climate condition for safety application. Front Panel 1 2 3 4 8 9 5 6 7 10 11 1 USB interface 7 7 band output level indicator light 2 132*32 lattice LCD display 8 CURSOR 3 MAIN MENU 9 SAVE / ENTER keystroke and and 4 RECALL 10 Input MUTE keystroke and MUTE display LED light 5 PARAMETERE encoder 11 Output MUTE keystroke and MUTE display LED light 6 7 band input level indicator light Version:V1.0 1 Rear Panel 1 4 3 2 5 1 Mains connector and power switch 4 2 channel input terminal 2 RS485 IN interface 5 RS485 OUT interface 3 6 channel output terminal System connection diagram Loudspeaker Loudspeaker Loudspeaker Loudspeaker Loudspeaker Power amplifier Power amplifier OUTPUT5 OUTPUT4 OUTPUT3 Power amplifier OUTPUT2 OUTPUT1 OUTPUT6 INPUT B RS485 INPUT RS485 OUTPUT RS485 to USB Adapter RS485 INPUT DIGITAL LOUDSPEAKER MANAGEMENT RS485 OUTPUT PC RS485 INPUT USB RS485 OUTPUT DIGITAL SPEAKER PROCESSOR Front Panel terminal resistor 2 Loudspeaker DIGITAL LOUDSPEAKER MANAGEMENT Mixing Console INPUT A Features µ 24-bit DSP technology, high performance AD/DA, simple operation and excellent performance. µ 2 in 6 out multi-kinds of crossover mode for flexible configuration. µ Input /output volume control with the range -40dB - +12dB and the minimum step 0.1dB. µ 7 band PEQ for each input and output, each band PEQ has various EQ choice as Parametric, L-Shelf 6dB, L-shelf 12dB, High-Shelf 6 dB, High-Shelf 12dB. µ PEQ frequency range: 19.7Hz to 21.9Hz, Gain range: -30dB to 15 +dB , bandwidth 0.017 to 4.750 octave. µ Output high-pass and low-pass filter, each filter has multi-kinds of slopes and types. Filter slope: -12dB - 24dB -36dB - 48dB. Filter type: Butterworth, Bessel, Linkwitz-Riley. µ The maximum 1000.00ms delay for each input/output channel with delay switch. µ The compressor in each input / output can adjust the threshold, ratio, attack time, release time, close,hard knee. Five step soft knee. µ Phase reversal function is set in each input / output channel. µ Channel setting copy function makes the adjusting much easier. µ Multi channel parameters can be set simultaneously via Multichannel linking function . µ Friendly and intuitive PC interface. USB, RS485 can be connected with PC. µ Multi processor network function. One computer can be connected with 3 kinds of processors (2 in 6 out) with the max 32 PCS for each model. µ 132X32 lattice LCD display. µ 7 band input/output level LED display. µ Mute LED light, keystroke indicator LED. µ Switch power: AC90V-250V, 50Hz-60Hz MAINS IN ~90V-250V 50/60Hz RS485 IN RS485 OUT 8 Signal Flow Chart delay X-over 7PEQ Phase Gain Mute Compressor Gain Mute Compressor OUT1 0¡~180¡ delay X-over 7PEQ Phase OUT2 0¡~180¡ Gain 7PEQ Compressor delay Mute IN A delay X-over 7PEQ delay X-over 7PEQ MATRIX Gain 7PEQ Compressor delay IN B Phase Gain Mute Compressor Gain Mute Compressor Gain Mute Compressor OUT3 0¡~180¡ Mute Phase OUT4 0¡~180¡ delay X-over 7PEQ Phase OUT5 0¡~180¡ delay X-over 7PEQ Phase 0¡~180¡ Gain Mute Compressor OUT6 Specification Input channel No. Output channel Number Input Impedance Output Impedance Max Input level Max output level Sampling frequency 2 6 10 kW 50 W 19dBu 19dBu 48kHz Input gain -40~+12dB,step 0.1dB Output gain Input delay Output delay Input PEQ number Output PEQ number -40~+12dB,step 0.1dB 1S, step 21uS 1S, step 21uS 7PEQ 7PEQ Input/output PEQ gain Input/output PEQ type Input/output PEQ Frequency Input/output PEQ bandwith High/Low Pass Filter Frequency High/Low Pass Filter Type High/Low Pass Filter Slope Compressor threshold Compressor ratio Compressor Attack time Compressor release time Dynamic Range Frequency Response CMRR CROSSTALK THD+N Max user program number Power Fuse Weight Size -30~+15dB,0.1dB/step PEQ Low shelf 6dB/12dB High shelf 6dB/12dB 19.7~21.9kHz 0.017~4.750 OCT 19.7~21.9kHz Bessel, Butterworth, Linkwitz-Riley 12dB,24dB,36dB,48dB -20~+20dBu,step 0.5dBu 1.2,1.5,2,3,4,6,10,20,40,128 1~100mS, step 1mS 50~1000mS, step 50mS 116dB A Weighting 20Hz~20kHz(±0.5dB) >50dB(30Hz~20kHz) <-100dB 0.003%(1kHz,0dBu) 30 90-240VAC 50/60Hz T1AL 250V 2.0kg 482*158*45mm Above specification is subject to change without prior notice. 8 UM_DSP226_01_EN www.dasaudio.com D.A.S. AUDIO, S.A. C/. Islas Baleares, 24 46988 Fuente del Jarro Valencia, SPAIN Tel. +34 96 134 0860 D.A.S. AUDIO OF AMERICA, INC. 6900 NW 52th Street Miami, FL. 33166 - U.S.A. TOLL FREE: 1 888 DAS 4 USA D.A.S. AUDIO ASIA PTE. LTD. 3 Temasek Avenue, Centennial Tower #34-36 Singapore 039190 Tel. +65 6549 7760