Thank you for purchasing the American Weigh HSeries digital hanging scale. Please read all operating
instructions carefully before use. This electronic scale
is a precision instrument. With normal care and proper
treatment, it will provide years of reliable service.
Never load the scale with more than the maximum
capacity. Overloading will permanently damage it!
Avoid any exposure to extreme heat or cold. Your
scale works better when operated at normal room
temperature. Always allow the scale to acclimate to
normal room temperature for at least one hour before
use.
Keep your scale in a clean environment. Dust, dirt,
moisture, vibration, air currents and a close distance to
other electronic equipment can all cause an adverse
effect on the reliability and accuracy of your scale.
Handle with care. Gently apply all items to be weighed
onto the hook. Although this scale is designed to be
quite durable, try to avoid rough treatment as this may
permanently damage the internal sensor.
Avoid shaking, dropping or otherwise shocking the
scale. This is a precision instrument and must be
handled with extreme care.
I. OPERATION
Place Scale on a horizontal flat surface.
1. Place the scale in a vertical position with no weight
on the hook.
2. Press the ON button. Wait until zero is displayed.
3. Hang the object(s) on the weighing hook.
4. Using the [SET] key, you can switch between the
weighing units. The scale will auto-off after 60 seconds
of no use.
II. TARE WEIGHING
1. Turn on scale as described above.
2. Place the "tare item" on the hook.
3. Press [TARE] and wait until zero is displayed.
4. Add the "net-weight-item".
III. ADVANCED CALIBRATION
Calibration is NOT required before first use. Only
calibrate if scale is not weighing properly.
1. Turn off the scale.
2. Press and hold the TARE and ON/OFF keys at the
same time.
3. Release the ON/OFF key first, then the TARE key.
4. You will see the offset number (~1000 - 1800)
5. Press TARE and CAL will flash followed by the first
required calibration weight.
6. Hang the first calibration weight from the hook and
press TARE.
7. The second reuired calibration weigh will be
displayed. Hang it on the hook and press TARE.
8. The third required calibration weight will be
displayed. Hang it on the hook and press TARE.
NOTE: To stop calibration, press ON/OFF at any time.
IV. TROUBLESHOOTING
The primary reasons for inaccuracy or malfunction
are low batteries, incorrect calibration, overload or
operating on an unstable surface. Please keep this in
mind and maintain and operate your scale properly.
This scale is a precise instrument and must be
handled with the utmost care and caution.
[Display] Elimination of errors
Nothing, Battery-Symbol, [lo] or [88888]
Change the batteries.
[OUt2]
Recalibrate the scale as shown above.
[EEEEE] You are overloading the scale. Remove the
excessive load immediately!
[LLLLL] The delicate weighing load cells have
been damaged by misusing the scale
(i.e. it was shocked, dropped or
overloaded). You can try recalibrating the
scale. If the load cell has not been
damaged too much it will work
again after recalibration.
[UNST]
Use the scale in a more stable position
Specifications
Model
H-11
H-22
H-66
H-110
Capacity
11 lb
5 kg
22 lb
10 kg
66 lb
30 kg
110 lb
50 kg
0.005 lb
2g
0.2 oz
0.01 lb
10 g
0.5 oz
0.02 lb
10 g
0.5 oz
0.05 lb
20 g
1 oz
Resolution
Tolerance
Min. Weight
Weighing Modes
Power
20 g
40 g
100 grams
lb, kg, lb/oz
2x CR2032 Batteries (included)*
*replacement requires small phillips head screwdriver
Auto-Off
60 seconds
Operating Temp.
32° - 104° F