Important Safety Warnings
This manual contains instructions and warnings that should be followed during the
installation, operating and storage of the UPS system. Please keep this manual for
further reference.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the
acceptable temperature and humidity range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances
such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment,
life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power
cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must during
UPS installation in order to reduce leakage current below 3.5mA.
Attention hazardous through electric shock. Also with disconnection of this unit from the
mains, hazardous voltage still may be accessible through supply from battery. The battery
supply should be therefore disconnected in the plus and minus pole at the quick connectors of
the battery when maintenance or service work inside the UPS is necessary.
CAUTION! Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required safety precautions. Keep unauthorized
personnel away from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or
mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and high short circuit current. The
following precaution should be observed before replacing batteries:
1)
Remove watches, rings, or other metal objects.
2)
Use tools with insulated handles.
3)
Wear rubber gloves and boots.
4)
Do not lay tools or metal parts on top of batteries.
5)
Disconnect charging source prior to connecting or disconnecting batteries terminal.
PowerStar User Manual
Uninterruptible Power Supply
Specifications
MODEL
CAPACITY
INPUT
Input Voltage
Voltage Range
OUTPUT
Voltage Regulation
Transfer Time
Waveform
BATTERY
Type & Number
Charging Time
PHYSICAL
Dimension (DxWxH) mm
Net Weight (kgs)
MANAGEMENT
USB Port
PSTAR650
650 VA / 360 W
PSTAR850
850 VA / 480 W
PSTAR1000
1000 VA / 600 W
230 VAC
162-290 VAC
+/-10%
Typical 2-6 ms, 10 ms max.
Simulated Sine Wave
12 V/7 AH x 1
12 V/9 AH x 1
12 V/7 AH x 2
4-6 hours recover to 90% capacity
287 x 100 x 142
4.25
4.9
350 x 146 x 160
8.0
Supports Windows® 2000/2003/XP/Vista/2008/7, Linux,
Unix, and MAC
Connection Chart
Installation & Operation

Initial Set-up
Surge Protected
Socket
Surge Protected
Socket
After unpacking the unit, please avoid placing the unit in direct sun light, excessive heat,
excessive humidity or in contact with fluids of any type. Place the unit away from other
equipment at least 20 cm to avoid interference.
Place the unit to avoid:
- Direct sunlight
Battery Backup
Sockets
- Excessive heat
- Excessive humidity or contact with fluids

 Connect Utility
Battery Backup
Sockets

1000
650/850
Status Indicator
AC mode LED: green
lighting
Battery mode LED:
yellow lighting
Fault LED: red lighting
Plug the UPS into an electrical outlet that does not share a circuit with a heavy electrical load.
Please allow the UPS to charge at least 6 hours prior to use.

 Connect Equipment
UPS status LED
AC Mode: green
lighting
Battery Mode: green
flashing
Connect critical equipment to “Battery Backup Sockets”. These battery backup sockets provide
battery back-up and surge protection. In case of power outage, battery power is automatically
provided to these outlets. Connect minor less critical devices to “Surge Protected Socket”.
Power is not supplied to this socket when the utility fails.
NOTE: Please DO NOT connect scanner or printer into “Battery Backup Sockets”.

 Connect Com. Port and Install Software
Connect the communication port cable end to the communication port located on the rear
Troubleshooting
Problem
No LED display on the
front panel.
panel of the UPS. Connect the other end of communication port cable to the port on the rear
panel of the computer.

Connect Modem/Phone/Network for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the
UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.
Power On/Off UPS
Press power switch on the front panel of the UPS to turn on UPS. Press switch again to turn
off the UPS.
Solutions
Charge the UPS at least 6 hours.
Battery fault.
Replace the battery with the same
type of battery.
Press the power switch again to turn
on the UPS.
Remove some loads first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
Remove some critical load.
The UPS is not turned on.
Download the software from http://www.power-software-download.com/viewpower.html.
Follow on-screen instruction to install the monitoring software.
Possible Cause
Low battery.
Alarm continuously
sounds when the
mains is normal.
The UPS is overload.
When power fails,
The UPS is overload.
back-up time is shorten.
Battery voltage is too low.
Charge the UPS at least 6 hours.
Battery defect. It might be due Replace the battery with the same
to high temperature operation type of battery.
environment, or improper
operation to battery.
The mains is normal but Power cord is loose.
Reconnect the power cord properly.
green LED is flashing.