Download ADT901User Manual.cdr
Transcript
Warnings and cautions Do not exceed the safety pressure limit(60 psi). Be careful of any problem by some pressure media against the exploisive or corrupsive conditon. Do not tighten connectors over to avoid any damage. Store the pump in the dry and non-corruptive environment. Any safety problems or damages caused by incorrect operation, is beyond Additel's responsibility. Specification Pressure range: 6 psi ( 0.4 bar ) vacuum to 6 psi ( 0.4 bar ) pressure Temperature: (0 ~ 50)℃ Humidity: < 95%RH ADT901 Low Pressure Test Pump User's Manual [Version number:1103V10] Adjusting fineness: 0.01Pa ( 0.0001 mbar ) Safety pressure: < 60 psi Pressure media: Air Size: Height: 5.71'' ( 145 mm ) Base: 9.65'' ( 245 mm ) x 6.50'' ( 165 mm ) Weight: 3.5 lb ( 1.6 kg ) Configuration & Air routine 1 2 3 Air routine 1-1/4 NPT quick connector 4 2- S hut off valve (clockwise to close/ anticlockwise to open) 5 3-Fine adjust handle (clockwise to increase pressure) 2 3 4-1/4 NPT quick connector 5-Coarse adjustment handle 5 (clockwise to increase pressure) Troubleshooting Problems Hard to coarsely adjust Hard to fine adjust Hard to turn the fittings Solutions Causes A. The isolating valve is not closed. Close the isolating valve. B. The sealing ring is broken or loosen. Replace sealing ring. A. The gauges are not tightened. Tighten the reference gauge or the gauge under test. B. The sealing ring is aged or frayed. Replace the sealing ring. C. The thread surface is not smooth. Put in a Teflon seals and turn it tightly. D. The connector type is unmatched. Use the right and suitable adapter. A. Too tightly turned last time! Do not apply much force to close the fittings and valves. B. The assembly is not fitted. New assembly needs time to abrode. C. The threads have no lubrication. Lubricate the thread. Basic Operation Connection A DIGITAL PRESSURE CALIBRATOR Units k SW SW V mA COM V mA COM 24V 24V Pressure Gauge k Open to atmosphere Pressure preparation B Increase pressure process Zeroing should be operated under this condition only. CALIBRATOR DIGITAL PRESSURE pressure transmitter pressure switch dial gauge C flexible hose Decrease pressure process D RE CALIBRATOR DIGITAL PRESSU CALIBRATOR DIGITAL PRESSURE Units Units Units 0 0 0 Pressure Gauge Pressure Gauge Pressure Gauge 0 k 0 k 0 0 ②turn it to the maximum degree ①open Prepare for vacuum ②fine adjust ③fine adjust ③set it to the mid position of its travel ①operate it to approach the desired value ②operate it to approach the desired value ①Close E Vacuum process F Decrease vacuum process Units Units Units 10 15 20 -25 20 0 -25 ②turn it to the maximum degree Vacuum Gauge 5 k 20 0 -25 ③fine adjust ①close 10 5 15 1 Vacuum Gauge 5 ③set it to the mid position of its travel ①open 10 15 Vacuum Gauge k G R URE CALIBRATO DIGITAL PRESS R URE CALIBRATO DIGITAL PRESS CALIBRATOR DIGITAL PRESSURE 0 k 5 k 0 ②fine adjust ②operate it to approach the desired value ①operate it to approach the desired value Remark: A: Additel has made a concerted effort to provide complete and current information for the proper use of the equipment. The product specifications and other information contained this manual are subject to change without notice. B: Above pictures are just for reference.