Download optimus green Sound Level Meters for Environmental
Transcript
BASIC OCCUPATIONAL ENVIRONMENTAL ADVANCED SPECIAL optimus green Sound Level Meters for Environmental & Occupational Noise Measurements Theoptimus redsoundlevelmetersusetheverylatestdigitaltechnologyandindustrialdesigntogiveyou theidealinstrumentforOccupationalandIndustrialHygienenoisemeasurements. Applications • SimultaneousF,S&ITimeWeightings • Environmentalnoiseimpactassessmentsover shortorlongperiods • Real-time1:1&1:3OctaveBandFilters • Occupational&IndustrialHygieneNoise Evaluations • Single120dBmeasurementrange • Tonalanalysisusing1:3OctaveBandFilters • Detailedanalysisusingaudiorecording • NoiseOrdinance&CommunityNoise Assessments • HearingProtectorSelectionusingHMLor1:1 OctaveBandMethods • 14StatisticalLn%values • Audiorecordingduringmeasurementsfor replayandanalysis • VoiceTag™audiorecordingbeforeeach measurementfornotetaking • Repeatingmeasurementswithmanualor automaticcontrol • GeneralNoiseMeasurements • Latestdigitaltechnologywithahighresolution colourOLEDdisplayandback-litkeypadfor night-timemeasurements Key Features • 4GBmemorycapableofstoringover10,000 measurements • Simpleoperationensuresthatyougetthe functionsyouneedquickly&easily • Compatiblewithoutdoornoisemeasurement kits • Simultaneousmeasurement&dataloggingof allavailableparameters • SimultaneousA,C&ZFrequencyWeightings Simple operation with advanced technology The optimus sound level meters have timenoisechartsothatyoucanseehow been designed with ease of use as the thenoisevarieswithtime. most important feature which lets you All of the functions of the instrument get on with measuring and controlling are measured simultaneously, and with thenoise. a wide 120dB measurement span you The instruments use the very latest in don’tneedtoworryaboutchoosingthe digital technology and industrial design rightrange. techniques to make everything as clear A standard optimus can measure up to andsimpleaspossible. 140dB(A) and 143dB(C) Peak with the Featuring a high resolution colour OLED standard microphone and preamplifier, screenandakeypadwhichwillilluminate and up to 170dB using the optional automatically in low light, the optimus MK:200EH High Level Noise microphone instruments are ideal for any noise system. application. Just switch on, calibrate and you are Themeasurementdataisdisplayedina readytogo. clearandsimpleformatalongwithareal- The ideal solution for environmental & occupational noise The optimus green sound level meters are Audio recordings can be stored ideal instruments for both environmental & eitherasStudio96/32qualitywhich occupationalnoiseandwillgiveyouallofthe can be used for later analysis, or informationyouneed,rightatyourfingertips. as Standard 16/16 quality which Everymeasurementcontainsalloftheavailable can be used for replay and source functions so there’s no risk of selecting the identification. wrongparameterorfunction. Repeating measurements Environmental Noise Measurements Measurementscanbeeitherstarted For environmental noise applications, an manually or automatically by the optimus greenistheidealinstrument. measurementcontrolfunctions. Comprehensive measurement capability Thisallowstheinstrumentstomake The overall Leq, Lmax and statistical Ln% values (14intotal)aremeasuredalongwitharange ofnoiseprofilesprovidingacompletepicture ofthenoiseunderinvestigation. Real-time 1:3 Octave Bands The B versions (CR:172B & CR:171B) will measureandstoreReal-Time1:3octavebands from 6.3Hz to 20kHz throughout each and every measurement, with the overall value repeated measurements over long periodsoftime,idealwhentheinstrumentis usedwithanoutdoornoisemeasurementkit. Occupational Noise & Industrial Hygiene Measurements Aswellastheenvironmentalnoisefunctions, the optimus green instruments also provide a complete range of occupational noise functions. alongwithatimehistorystoredautomatically. UK & EU Noise at Work Regulations Audio recording IfyouareworkingtotheUKControlofNoise AswellastheVoiceTagrecording,theoptimus green instruments provide audio recording duringmeasurements. This can be either started manually during the measurement or triggered using a sophisticatedsetofthresholdparameters. atWorkRegulationsortheEUPhysicalAgents (Noise) Directive, LAeq and LCPeak values are measured at the same time which allow the LEP,d (LEX,8h) and the Peak Action Levels to be determined. The exposure calculator also displaysaprojectedLEP,d(LEX,8h)forthecurrent measurement. The LCeq-LAeq (C-A) value is also measured whichcanbeusedtoselectPPEusingtheHML method. OSHA, MSHA & other regulations If you need to meet regulations such as OSHA HC & NC, MSHA HC or ACGIH, the two “virtual”noisemetersintheDoseViewcanbe quickly configured to provide you with this information. Octave Band Filters for Noise Control & Selecting Hearing Protection The optimus green instruments also feature real-time1:1octavebandfilterswhichcanbe usedtoaidintheselectionofPPEandfornoise controlapplications. NoiseTools Software For many users, the most challenging part of a noise survey is the Measurements can be sorted or grouped by any parameter, person, reportingandanalysisoftheresults,andsohavingasimplewaytoview, placeorproject,andmeasurementreportscreatedquicklyandeasily. analyseandprinttheinformationisessential. NoiseTools is fully compatible with the latest versions of Microsoft ThenewNoiseToolssoftwarepackagegivesyouaquickandsimpleway Windowsand,aswithallCirrussoftware,updatesareavailablefreeof todownload,analyseandreportyournoisemeasurementinformation. chargefromtheCirruswebsite. Intuitive and simple to use NoiseToolsissuppliedfreefromanylicensingrestrictionsorlimitsallowing The initial summary screen shows you the most commonly used youtoinstalltheprogramonasmanyPC’sasneededatnoadditional informationand,throughsimpleicons,givesyouaccesstothedetailed cost.UpdatesfortheNoiseToolssoftwareareavailablefree measurementdata.Youcansimplyprintthesummaryscreentogeta ofchargefromtheCirrusResearchplcwebsite. quickmeasurementreport. Foradvancedusers,eachandeveryfunctionmeasuredbytheinstrument is available for review and analysis and the data can be exported for furtheruse. VoiceTag recordings can be played back for reference and are automaticallystoredwiththemeasurementdata. Audio recordings can be played back to identify the noise source and analysisperformedontherecordings. Where Octave Band data is available, this information can be used by theprogramtocalculatethelevelofprotectionfromarangeofhearing defendersandearplugs. Helping you keep your data organised Overtime,youmayfindthatyouhavealargenumberofmeasurements, informationandnotes. Tohelpyoukeepyournoisemeasurementdataorganisedandeasyto find, NoiseTools allows each measurement to be allocated to people, placesandprojects. Instrument Range & Measurement Kits Theoptimus green soundlevelmeterscanbeusedforawiderangeof occupationalandenvironmentalnoiseapplicationsandyoucanchoose fromtwosimpleoptionstogettheinstrumentthatmeetsyourneeds. ChoosefromClass1orClass2performance,andeitherAudioRecording with1:1Real-TimeOctaveBandFilters(AVersioninstruments)orAudio Recording with Real-Time 1:1 & 1:3 Octave Band Filters (B Version instruments). AlloftheinstrumentscanmeasureSoundLevelfunctionsplusLmaxand Lmin with all frequency and time weightings, as well as real-time 1:1 Octave Band filters, Integrated noise levels such as LAeq,t and LAE, C-A, PeakSoundPressureandvirtualnoisemetersforOSHA/MSHA/ACGIH. 14independentLnvaluesareavailablealongwiththeothermeasurement functions. Specificationsandaselectionchartareavailableonthefollowingpage. Complete measurement kits are available for the optimus instruments whichcontainthesoundlevelmeter,anacousticcalibrator,windshield, cables,batteriesandaccessories.Themeasurementkitscontainallofthe accessoriesneededtocarryoutanoisesurvey. Specifications Applicable Standards IEC61672-1:2002Class1orClass2GroupX IEC60651:2001Type1IorType2I IEC60804:2000Type1orType2 IEC61252:1993PersonalSoundExposureMeters ANSIS1.4-1983(R2006),ANSIS1.43-1997(R2007) ANSIS1.25:1991 1:1&1:3OctaveBandFilterstoIEC61260&ANSIS1.112004 Measurement Control Measurementcontrolwithuserselectabledurationofmanual, 1min,5min,10min,15min,30mins,1hour,Lden AutomaticSynchronisation&Repeat Integrators Threesimultaneous“virtual”noisemeters Integrator1ispresettoQ3forLeqfunctions Integrators2&3canbeconfiguredwiththefollowing: ExchangeRate:Q3,4or5 Threshold:70dBto120dB(1dBsteps) TimeWeighting:NoneorSlow CriterionLevel:70dBto120dB(1dBsteps) CriterionTime:1to12hoursin1hoursteps Microphone Class1InstrumentsMK:224pre-polarized Class2InstrumentsMK:216pre-polarized Microphone Preamplifier MV:200ERemovablePreamplifier Frequency Weightings RMS&Peak:A,C,&ZMeasuredSimultaneously 1:1OctaveBands:16Hzto16kHz(31.5Hzto16kHzdisplayed, 16Hzstored) 1:3OctaveBands:6.3Hzto20kHz(Bandsfrom12.5Hz displayed,6.3Hz,8Hz&10Hzstored&downloaded)-B Version AdditionalMetrics:LAeqLF(20Hzto200Hz)&LeqLF(20Hzto 200Hz) Time Weightings Fast,Slow&ImpulseMeasuredSimultaneously Size 283mmx65mmx30mm Weight 300gms/10oz CR:172B & CR:171B LXY,LXYMax,LXYMin LXeq,LCPeak,LZPeak,LCeq-LAeq,LXE GraphofShortLAeq,LCPeak MeasurementRunTime Integrators2&3:TWA,Dose%,EstDose% Real-Time1:1OctaveBands(Graphical&Numeric) Real-Time1:3OctaveBands(Graphical&Numeric) LeqLF(20Hzto200Hz) 14StatisticalLn%Values Batteries 4xAAAlkaline,batterylifetypically12hours External Power 5vviaUSBSocketfromPCorPowerSupply 5v-15vviaMultiIOsocket Tripod Mount 1/4”Whitworthsocket Display HighresolutionOLEDdisplaywithambientlightsensor& illuminatedkeypad Connections USBTypeBtoPC,Multi-pinIOforexternalpower&RS232 Memory 4GBasstandardwithupto10,000measurementsstored. Expandableto128GB Case Material:HighImpactABS-PCwithsofttouchback&keypad Environmental Temperature Operating-10°Cto+50°C Storage-20°Cto+60°C Humidity Upto95%RHNonCondensing Time History Data Rates (Global settings) 10ms,62.5ms,125ms,250ms,1/2sec,1sec,2sec VoiceTag Audio Recording 30secondsofaudiorecordingwitheachmeasurement Electromagnetic performance IEC61672-1:2002&IEC61672-2:2003,Exceptwheremodified byEN61000-6-1:2007&EN61000-6-1:2007 Audio Recording Off,Manual,ThresholdTriggered,AdvancedTrigger UseroptionsofStudio(96kHz/32bit)orStandardquality (16kHz/16bit)WAVformat Ln Statistical Values 14independentstatisticalLnvaluescalculatedfrom1/16thLAF 7presettoL1.0,L5.0,L10.0,L50.0,L90.0,L95.0&L99.0 7userdefinedLnvalues NoiseToolsallowsforusercontroloffrequencyweighting usedforLncalculations.dB(A),dB(C)ordB(Z)available CR:172A & CR:171A LXY,LXYMax,LXYMin LXeq,LCPeak,LZPeak,LCeq-LAeq,LXE GraphofShortLAeq,LCPeak MeasurementRunTime Integrators2&3:TWA,Dose%,EstDose% Real-Time1:1OctaveBands(Graphical&Numeric) 14StatisticalLn%Values Stored Functions LXYMax&TimeHistoryofLXYMax LAeq,LCeq,LZeq,LCPeak,LZPeak TimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak Integrators2&3:LAVG,TWA.%Dose TimeHistoryofLAVG 1:1OctaveBands:OverallLeq&LeqTimeHistoryforeachband LnValues:14independentstatisticalvalues AudioRecordingDuringMeasurement MeasurementRunTime Time&DateofMeasurementStart Integrator Quick settings EU,OSHAHC&OSHANC,OSHAHC&ACGIH MSHAHC&MSHAEC,Custom1&Custom2 Total Measurement Range: 20dBto140dBRMSSingleRange NoiseFloor:<18dB(A)Class1,<21dB(A)Class2 Measurement Functions1 Stored Functions LXYMax&TimeHistoryofLXYMax LAeq,LCeq,LZeq,LCPeak,LZPeak TimeHistoryofLAeq,LCeq,LZeq,LCPeak,LZPeak Integrators2&3:LAVG,TWA.%Dose TimeHistoryofLAVG 1:1&1:3OctaveBands:OverallLeq&LeqTimeHistoryfor eachband LnValues:14independentstatisticalvalues AudioRecordingDuringMeasurement MeasurementRunTime Time&DateofMeasurementStart wherex=A,C,Z;y=F,S,I OtherfunctionsmaybecalculatedbytheNoiseToolssoftware anddisplayedondownload. Language options English,French,German,Spanishasstandard Otherlanguageoptionsmaybeavailable Software Support NoiseToolsDownload,Configuration&Analysissoftware suppliedasstandard.CompatiblewithMicrosoftWindowsXP, Vista&7(32bit&64bit) Notes 1.Fordetailsofthedisplayedandstoredparameters,pleaserefertothe optimusgreentechnicalspecificationdatasheet. Allspecifications,featuresandvaluesaretypicalandaresubjecttochange withoutnotice. Instrument Selection Function Class1 Class2 SoundLevel Functions Leq/Peak Functions TWA/Dose Functions Data Logging Audio Recording VoiceTag Recording 1:1Octave BandFilters Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1:3Octave BandFilters Ln/Timer Software Support Measurement Kit Yes Yes Yes CK:172A Yes Yes Yes CK:171A Yes Yes Yes CK:172B Yes Yes Yes CK:171B Instrument CR:172A CR:171A Yes CR:172B CR:171B Yes Yes Standard Accessories Theoptimussoundlevelmetersaresupplied,asstandard,withthefollowing accessories: UserManual CertificateofCalibration USBData/PowerCable Windshield NoiseToolsSoftwareCD AcousticHouse BridlingtonRoad Hunmanby NorthYorkshire YO140PH UnitedKingdom cr17x/07/2010/r3EN T:08452302434(UK) +441723891655 F:+441723891742 E:[email protected] W:www.cirrusresearch.co.uk Measurement Kits Theoptimussoundlevelmetersareavailableasacompletemeasurementkit withthefollowingaccessories: optimusSoundLevelMeter CR:514Class2orCR:515Class1AcousticCalibrator UA:23790mmWindshield CK:280CarryingCase UserManual&CertificatesofCalibration USBData/PowerCable&NoiseToolsSoftwareCD