Transcript
Side B JY997D17101C Side A Side JAPANESE B ENGLISH Applicable standard 2. Installation and Remove FX3U-7DM units made in May, 2005 or later comply with the EC Directive (EMC Directive). Further information can be found in the following manual. However, the FX3UC-32MT-LT does not comply with the EC Directive (EMC Directive). → Refer to the FX 3U Series Hardware Manual (Manual No. JY997D18801) 1. Outline Manual Number JY997D17101 1.1 Incorporated Items Revision C Verify that the following product and items are included in the package: Date September 2007 FX3U-7DM display -module Manual FX3U Unit: mm (inches) MASS (Weight): Display module 20g (0.05lbs) Display module mounting top cover 10g (0.03lbs) Model Item Display device/ backlight Number of letters 16 letters × 4 lines (2 byte letter: 8 letters × 4 lines) 26 R WE 20 21 PO 13(0.52") [4] "+" button Use to move cursor or set the value. [5] "OK" button Use to choose the item, set the value, etc. E x pl a i n s t h e F X 3 U C S e r i e s P L C specifications for I/O, wiring, installation, and maintenance. FX3U-7DM 24V X0 X1 X2 X3 X4 X5 X6 X7 X10 X12 X11 IN X13 X14 X15 X16 X17 X20 X21 17 16 15 14 13 12 2 11 10 16 15 14 13 12 11 10 ER W N PO BA RU 21 20 5V DC, 20 mA is supplied from the internal power supply of the main unit. 17 16 15 14 13 12 11 4. Function List /ES MR -48 For the function list, refer to the PLC main unit manual. → Refer to the FX 3U Series User's Manual - Hardware Edition → Refer to the FX 3UC Series User's Manual - Hardware Edition X22 X23 L N S/S 0V 24V X0 X1 X2 X3 X4 X5 X6 X7 X10 X12 X11 0 1 2 3 4 5 6 7 20 21 22 23 24 IN 10 11 12 13 14 15 16 17 POWE X13 X14 X15 X16 X17 X20 X21 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual. E 4) Place the G side of the display module mounting top cover (fig. F) onto the main unit (fig. D). 5) The display module mounting top cover (fig. F) is installed in the Main module (fig. D) as shown in the right figure. F D 20 7 6 17 5 16 4 15 3 14 2 13 1 12 0 11 IN 10 0 T OU FX3UFX3U-48M FX RUN X22 G 5) P STO /ES MR -48 1 21 22 23 24 27 26 25 R WE PO RU N B 2 3 4 5 6 7 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. 0 1 2 3 4 5 6 7 20 21 22 23 10 11 12 13 14 15 16 17 PO RU For safe use BAT How to obtain manuals For product manuals or documents, consult with the Mitsubishi Electric dealer from who you purchased your product. 3.4 Power Supply Specifications 7 6 5 4 3 2 1 FX3U-48MR/ES Install to control panel → For installation, refer to FX3U-7DM-HLD User's Manual. For the operation of the display module, refer to the PLC main unit manual. 0V FX 27 26 25 24 23 22 21 17 0 P FX3U-7DM-HLD S/S 20 7 16 STO FX3U-7DM N 6 15 Fixes the display module installing top cover on PLC. Install to main unit L 5 14 N RU 1.3 Installation Example → Refer to the FX3U Series User's Manual - Hardware Edition → Refer to the FX3UC Series User's Manual - Hardware Edition 4 13 21 JY997D28701 MODEL CODE: 09R519 3 12 20 FX3UC Series User’s Manual - Hardware Edition 11 17 Explains the FX 3U Series PLC specifications for I/O, wiring, installation, and maintenance. 10 16 JY997D16501 MODEL CODE: 09R516 2 1 15 FX3U Series User’s Manual - Hardware Edition 0 14 JY997D15401 3) 3)’ 13 Description Explains the FX 3U -7DM-HLD display mod ul e ho l de r s pe c i fi c at io ns fo r external dimensions and installation. C D T Use to move cursor or set the value. 10 Use to cancel operation or return to previous screen. [3] "-" button OU [2] "ESC" button [6] Connector for main unit Used to connect display module to main unit. Manual No. The general specifications are equivalent to the PLC main unit. For general specifications, refer to the following manuals. → Refer to the FX 3U Series User's Manual - Hardware Edition → Refer to the FX 3UC Series User's Manual - Hardware Edition 3) When installing Install the display module (fig. C) to E on the main unit (fig. D) as indicated with the arrow 3). When removing Remove the display module (fig. C) from the main unit (fig. D) as indicated with the arrow 3)'. Displays current time and monitored status of device. [7] Top cover fixing hook Japanese/English 4 operation buttons (OK, ESC, +, and -) 3.3 General Specifications Description [1] Display Alphabets, Numbers, Japanese character, Shift JIS Level-1, 2 N 66.3(2.62") 12 Manual name FX3U -7DM-HLD User’s Manual Button 11 Associated Manuals /ES MR -48 10 may Name FX3U 7 6 5 4 3 2 1 Displayed Character letters Language for menu display 3U FX IN Depending on the circumstances, procedures indicated by also cause severe injury. It is important to follow all precautions for personal safety. No. 5 -48M FX3U3U-48M FX 3U Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. 11.5 [5] (0.46") 4 Description STN monochrome liquid crystal display/ Backlight: LED (green) ST Approx. 8.5(0.34") [4] 48(1.89") 3 Ver. 1.00 or later (from first production) RU [7] 3U . Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. 2 FX3UC-32MT-LT PLC* OP 35 (1.38") and [6] [2] [3] [1] This manual classifies the safety precautions into two categories: 1 0 T OU 41.8(1.65") Safety Precaution (Read these precautions before use.) 0 IN Ver. 2.20 or later (from first production) 3.2 Display Specifications 7 6 Applicability FX3U Series PLC * FX 3UC-32MT-LT has this display module provided as standard equipment. 2 Display module mounting top cover 22 Display module 3.1 Applicable PLC The following section describes the installation method for the FX3U/FX3UC -32MTLT Series PLC (FX3U Series PLC is used for the following example). For more details on installation and removal, refer to the PLC main unit manual. → Refer to the FX 3U Series User's Manual - Hardware Edition → Refer to the FX 3UC Series User's Manual - Hardware Edition 1) Power off the PLC. B 2) Pushing the top cover hook (fig. A), remove the top A cover (fig. B), as shown in the right figure. 1.2 External Dimensions and Part Names © 2005 Mitsubishi Electric Corporation • The product is a precision instrument. During transportation, avoid any impacts. Failure to do so may cause failures in the product. After transportation, verify the operations of the product. • Use the product within the generic environment specifications described in PLC main unit manual (Hardware Edition). Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive gas (salt air, Cl 2, H 2S, SO2, or NO2), flammable gas, vibration or impacts, or exposed to high temperature, condensation, or rain and wind. If the product is used in such conditions, electric shock, fire, malfunctions, deterioration or damage may occur. • Do not touch the conductive parts of the product directly. Doing so may cause device failures or malfunctions. • Connect display module securely to their designated connectors. Loose connections may cause malfunctions. This manual Effective September 2007 Specifications are subject to change without notice. INSTALLATION PRECAUTIONS 25 This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions. Store this manual in a safe place so that it can be taken out and read whenever necessary. Always forward it to the end user. Registration: The company and product names described in this manual are registered trademarks or the trademarks of their respective companies. Display module mounting top cover TRANSPORT AND STORAGE PRECAUTIONS 24 USER'S MANUAL The FX3U-7DM display module (hereinafter called display module) is installed to the FX3U / FX3UC-32MT-LT (provided as standard equipment) PLC main unit to display messages (alphabet, numbers, and Japanese characters) or to monitor/change device states. • Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device. • Make sure to cut off all phases of the power supply externally before attempting installation or wiring work. Failure to do so may cause electric shock or damage to the product. 23 FX3U-7DM DISPOSAL PRECAUTIONS INSTALLATION PRECAUTIONS OUT FX3U Y0 Y2 COM1 Y1 Y3 R Y4 Y6 COM2 Y5 Y7 ERRO 0 1 2 3 4 5 6 7 20 21 22 23 24 10 11 12 13 14 15 16 17 Y10 Y12 COM3 Y11 Y13 OUT FX3U Y14 Y16 Y20 Y22 COM4 Y15 Y17 Y21 Y23 Y0 Y2 COM1 Y1 Y3 Y4 Y6 COM2 Y5 Y7 ER 0 1 2 3 4 5 6 7 20 21 22 23 10 11 12 13 14 15 16 17 Y10 Y12 COM3 Y11 Y13 Y14 Y16 Y20 Y22 COM4 Y15 Y17 Y21 Y R 3. Specifications STARTUP AND MAINTENANCE PRECAUTIONS • Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions. * For repair, contact your local Mitsubishi Electric distributor. • Do not drop the product or exert strong impact to it. Doing so may cause damage. • This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. • Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric. • This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system. HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN