Download Oblica Bathysca Focus Hublot

Transcript
bathyscafocus
hublot:
Installation and
User Manual
1. Technical Data
2
2. PRE-Installation
3
3. INSTALLATION
5
4. Operation
13
5. efficiency and emissions test
14
6. installation clearance test
15
Keep for future use
Oblica
200 Argyle St
Fitzroy VIC 3065
03 9416 0400
1. Technical Data
Weight and dimensions:
Firebox diameter
Firebox weight
Flue diameter
Flue weight
Standard bracket weight
External flue kit
700mm
68Kg
219mm
16Kg/meter
20Kg
Triple skin 200/250/300mm
Determined under test conditions:
Nominal thermal output
Efficiency
17.8kW
55,8%
FLUE
ø219 mm
FIREBOX
ø700 mm
500 mm
oblica | bathyscafocus hublot Installation and User Manual
page 2
2. Pre-INSTALLATION
Congratulations on your purchase of the BathyscaFocus Hublot. This appliance should be installed and checked by a
qualified professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or
concerns please contact Oblica on 03 9416 0400.
The installation process is outlined below:
– Determine position of firebox and flue carefully observing the clearances described within this section
– Install the suspension bracket
– Install the external flue
– Install the internal flue and engage the firebox
– Ensure the floor has adequate protection
Caution:
Using components or parts other than those provided by the manufacturer or modifying the specification of components
may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the first instance.
Warning:
• The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the
relevant building code or codes.
• Any modification of the appliance that has not been approved in writing by the testing authority
will be in breach of the approval granted for compliance with AS/NZS 4013.
• Once the flue has been installed and approved by a professional installer, the flue must not be
modified in any way.
oblica | bathyscafocus hublot Installation and User Manual
page 3
2. Pre-INSTALLATION (CONTINUED)
MINIMUM CLEARANCE – INTERNAL
2.1 Clearance from non-combustible surfaces
(eg masonry)
2.3 Clearance from combustible surfaces
(eg timber joist & plasterboard)
300mm minimum clearance is required from fully
non-combustible surfaces.
1000mm minimum clearance is required on all sides
when the BathyscaFocus Hublot can rotate 360˚ .
Non Combustible Non Combustible
Non Combustible
300
Combustible
750
Combus
FIXED
300
2.2 Clearance from glass
FULLY ROTATING
1000
1000
FULLY ROTATING
1000
750
Combustible
Non Combustible
FULLY ROTATING
300
Combust
Combustible
300
FULLY ROTATING
1000
1000
Combustible
Non Combustible
FULLY ROTATING
Non Combustible
300
300
Combustible
Combustible
(frameless or aluminium frame)
Combustible
500
FULLY ROTATING
500
Combustible
750
FIXED
Combustible
FULLY ROTATING
Combustible
Non Combustible
1000
Glass
(frameless or aluminium frame)
Glass
Glass
(frameless
(frameless or aluminium
frame)or aluminium frame)
FIXED
Glass
Glass clearance is
500mm
minimum
required from
normal
(frameless
or aluminium
frame)
(frameless or aluminium
frame)
750mm minimum
clearance
from
the
back
and
1000
FULLY ROTATING
non-combustible glass.
1000mm from the side is required if the rotation of the
500
500
350mm minimum clearance is required from
BathyscaFocus Hublot is locked at 90˚ away from the
toughened glass.
wall. Locking the BathyscaFocus Hublot so that the
opening is fixed is an option available on purchase.
Glass
500
500
FULLY ROTATING
FULLY ROTATING
1000
1000
Glass
(frameless or aluminium fram
IMPORTANT:
Frames must also be considered. Timber window
frames must be treated as combustible surfaces
(see 2.3). Aluminium frames can be treated as
non-combustible surfaces (see 2.2).
oblica | bathyscafocus hublot Installation and User Manual
Clearances may be reduced with the application
of heat shielding to walls in accordance to the
Australian Building Code.
For information on heat shielding please contact our
office on 03 9416 0400 or email [email protected].
page 4
3. InstallATION
3.1 Installing the suspension bracket
• The bracket must be structurally secured within the roof as shown in the diagram below.
• The largest cylinder must project down from the ceiling by at least 150mm (BCA requirement) unless
the ceiling is made from a non-combustible material such as concrete.
•You must leave a 25mm clearance gap between the bracket and the ceiling. This gap will be covered by
the ceiling Flange.
• 12mm ventilation gap between the plasterboard and the ceiling flange
• 25mm minimum clearance from the triple skin flue to any combustible material within the roof space
• 40mm minimum overlap of the stainless steel 8” flue into the connector
Typical Flat ROOF INSTALLATION
CHINAMAN HAT
(Anti-Down-Draft device)
TRIPLE SKIN FLUE
200 X 250 X 300
(8’ x 10’ x 12’)
RUBBER FLASHING
250
Insulative pad
25
CROSS BAR SET IN-BETWEEN RAFTERS
CEILING FLANGE
150
12
( Plaster Ceiling Minimum Gap)
40
SUSPENSION BRACKET
CONNECTOR
LOWER FLUE 219mm dia.
oblica | bathyscafocus hublot Installation and User Manual
page 5
3. InstallATION (CONTINUED)
12
oblica | bathyscafocus hublot Installation and User Manual
150
25
Custom Length & Angle
PITCHED ROOF INSTALLATION (Custom Made Bracket)
page 6
3. InstallATION (CONTINUED)
3.2 Installing the external flue
1.Place the connection piece inside the suspension bracket. This will join the single skin flue below the
bracket and the triple skin flue above the bracket which have different diameters.
2.Ensure the triple skin flue is installed as per Australian standards (see diagrams below).
Pitched roof installation
The top of the flue must be 400mm higher than the highest point of the roof. Alternatively, there must be a
minimum distance of 8 meters from any higher section of roof.
–> 40 cm
–> 40 cm
>
–8m
> 40
– cm
–> 40 cm
>
–8m
> 40
– cm
–> 40 cm
cm
–> 120
Flat roof installation (less than 5˚
pitch)
–> 120 cm
>
–8m
>
– 120 cm
The top of the flue must be 1200mm above the roofline. Alternatively, there must be a minimum distance of
8 meters from any higher section of roof.
–> 120 cm
–> 120 cm
oblica | bathyscafocus hublot Installation and User Manual
>
–8m
>
– 120 cm
page 7
3. InstallATION (CONTINUED)
3.3 Installing the internal flue
Position the single skin flue inside the suspension bracket and tighten the grab screws.
Ensure that the flue is perfectly vertical and the grab screws are tight.
1
2
Grab Screw
3
oblica | bathyscafocus hublot Installation and User Manual
4
page 8
3. InstallATION (CONTINUED)
5
6
7
8
oblica | bathyscafocus hublot Installation and User Manual
page 9
3. InstallATION (CONTINUED)
9
10
11
12
oblica | bathyscafocus hublot Installation and User Manual
page 10
3. InstallATION (CONTINUED)
3.4 Protecting the floor
•Any combustible floor beneath a fireplace must have a floor protector that extends 300mm beyond the
diameter of the firebox in all directions.
•If installed directly on combustible material, the floor protector must be made of a minimum 6mm thick cement
sheet. Non-combustible finishes can be applied to the floor protector (tiles, steel sheet, light concrete, etc).
• If the combustible floor is installed on concrete, you can replace the combustible material with noncombustible material laid directly onto the concrete.
Floor protector laID on timber floor
Combustible
floor (eg. timber)
Combustible
floor (eg. timber)
300mm
Insulative board (6mm)
+ non combustible finish
Insulative board (6mm)
+ non combustible finish
300mm
Combustible
floor (eg. timber)
Combustible
floor (eg. timber)
300mm
Non comb
(eg.tiles)
Non comb
(eg.tiles)
300mm
Joist
Concrete
Joist
Concrete
Floor protector laId on Joist
Combustible
floor (eg. timber)
Combustible
floor (eg. timber)
FIREBOX
FIREBOX
300mm
Insulative board (6mm)
+ non combustible finish
Insulative board (6mm)
+ non combustible finish
300mm
Joist
Joist
oblica | bathyscafocus hublot Installation and User Manual
page 11
300mm
300mm
3. InstallATION (CONTINUED)
Floor protector lAID on CONCRETE
Combustible
300mm
Non combustible finish
(eg.tiles)
floor (eg.300mm
timber)
mbustible
or (eg. timber)
Non combustible finish
(eg.tiles)
Concrete
Concrete
TOP VIEW
FIREBOX
300mm
Floor protector /
non combustible finish
FIREBOX
300mm
Combustible floor (eg. timber)
Floor protector /
non combustible finish
Combustible floor (eg. timber)
oblica | bathyscafocus hublot Installation and User Manual
page 12
4. OPERATION
4.1 What you should burn
• Untreated, air dried hardwood
•Split logs with a humidity content of less than 20%
4.2 Do not burn
• Trash
• Painted plastic
• Coated or preservative treated wood
• Waste or black coal
•Inflammable liquids
• Fire gels
•Moist wood with a residual humidity content of more than 20% (this may cause soothing of the chimney).
IMPORTANT:
•Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee.
• The maximum load capacity for the Bathyscafocus Hublot is 20kg of wood.
• Burning only seasoned hardwood helps to protect the environment and lower emissions.
For details of a wood supplier in your area please call our office on 03 9416 0400 or email [email protected].
Warning:
• Do not use flammable liquids or aerosols to start or rekindle the fire.
• Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating.
• Do not store fuel within prescribed installation clearance distances.
• The use of some types of preservative-treated woods as a fuel can be hazardous.
oblica | bathyscafocus hublot Installation and User Manual
page 13
5. efficiency and emissions test
TEST REPORT No 30A-13-0024-TRP-349704-0
TESTING LABORATORY: VIPAC Engineers and Scientists
MANUFACTURER: Focus
MODEL:
Bathysca Porthole
WORK REQUESTED: Assessment of appliance to AS/NZS 4012:1999
for determination of Power Output and Efficiency
and AS/NZS 4013:1999 for Flue Gas Emission
using hardwood fuel.
issue DATE: 09/07/2014
INVESTIGATING OFFICERs: Christain Schmidt, Rebecca Searcy
RESULTS:
The appliance particulate emission factor established
in testing is 1.2g/kg of dry wood, within the maximum
specification of 4.0g/kg of dry wood.
CONCLUSION:
This appliance does comply with the requirements
of AS/NZS 4013:1999 for the configuration tested.
oblica | bathyscafocus hublot Installation and User Manual
page 14
6. installation clearance test
TEST REPORT No 30A-13-0024-TRP-349705-0
TESTING LABORATORY: VIPAC Engineers and Scientists
MANUFACTURER: Focus
MODEL:
Bathysca Porthole
WORK REQUESTED: Assessment of appliance in one configuration to
AS/NZS 2918:2001 Appendix B, with a full length flue kit.
issue DATE: 09/07/2014
INVESTIGATING OFFICERs: Christain Schmidt, Rebecca Searcy
CONCLUSION:
This appliance does comply with the requirements of
AS/NZS 2918:2001 Appendix B for the configuration tested.
oblica | bathyscafocus hublot Installation and User Manual
page 15