Download Invicta TURN Informaion

Transcript
Skantherm
Turn:
Installation and
User Manual
1. Technical Data
2
2. PRE-Installation
3
3. Installation
5
4. Operation
9
5. TestING
10
Keep for future use
Oblica
200 Argyle St
Fitzroy VIC 3065
03 9416 0400
1. Technical Data
Weight and dimensions:
Dimensions
Firebox weight
Flue kit
W1150 x H852 x D382mm
213kg
Standard 6”
Determined under test conditions:
Nominal thermal output
Efficiency
5kW
78,4%
FLUE
852
Standard 6”
1150
oblica | turn Installation and User Manual
page 2
2. Pre-INSTALLATION
Congratulations on your purchase of the Turn. This appliance should be installed and checked by a qualified
professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or concerns
please contact Oblica on 03 9416 0400.
The installation process is outlined below:
– Determine position of firebox and flue carefully observing the clearances described within this section
– Install the external flue
– Install the internal flue and engage the firebox
– Ensure the floor has adequate protection
Caution:
Using components or parts other than those provided by the manufacturer or modifying the specification of components
may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the first instance.
Warning:
• The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the
relevant building code or codes.
• Any modification of the appliance that has not been approved in writing by the testing authority
will be in breach of the approval granted for compliance with AS/NZS 4013.
• Once the flue has been installed and approved by a professional installer, the flue must not be
modified in any way.
oblica | turn Installation and User Manual
page 3
2. Pre-INSTALLATION (CONTINUED)
MINIMUM CLEARANCE – INTERNAL
2.1 Clearance from non-combustible surfaces
(eg masonry)
2.3 Clearance from combustible surfaces
(eg timber joist & concrete)
100mm minimum clearance is required from fully
non-combustible surfaces.
Clearances may be reduced with the application of
heat shielding to walls in accordance to the
Australian Building Code. Combustible
Non Combustible
280
100
For information on heat shielding please contact our
office on 03 9416 0400 or email [email protected].
Co
m
st
ib
le
420
bu
st
ib
Co
m
bu
le
Co
st
ib
l
Co e
m
bu
0
le
bu
st
ib
le
m
bu
st
ib
0
le
Co
0
14
bu
st Com
ib
bu
le
st
ib
m
Co
14
m
bu
14
st
ib
le
m
Co
0
14
14
0
0
0
IMPORTANT:
Frames must also be considered. Timber window
frames must be treated as combustible surfaces
(see 2.3). Aluminium frames can be treated as
non-combustible surfaces (see 2.2).
oblica | turn Installation and User Manual
Combustible
Combustible
420
14
400
0
400
14
400
400
400
400
420
Configuration 2 – Corner installation
14
Glass
Glass (frameless or aluminium frame)
(frameless or aluminium frame)
Glass
(frameless or aluminium frame)
Glass
(frameless or aluminium frame)
400
400
Glass
(frameless or aluminium frame)
Glass
(frameless or aluminium frame)
Combustible
Combustible
500mm minimum clearanceGlass
is required from normal
(frameless or aluminium
100 frame)
non-combustible glass.
350mm minimum clearance is required from
toughened glass.
Glass
(frameless or aluminium frame)
Combustible
280
Non Combustible
100
Combustible
280
Non Combustible
100
100
2.2 Clearance from glass
420
Combustible
Non Combustible
100
Non Combustible
Configuration 1 – Parallel installation
280
100
Non Combustible
Non Combustible
100
Non Combustible
page 4
3. InstallATION
3.1 Typical flue kit installation
Cowl (Chinaman Hat)
8” Outer Case
10” Outer Case
RUBBER
DEKTITE FLASHING
6” Active Flue
8” Outer Case
10” Outer Case
CEILING RING
8” Outer
decorative
casing
6” Active Flue
Crimped end up
on dec outer case
8” Outer
decorative
casing
FIREBOX
oblica | turn Installation and User Manual
page 5
3. InstallATION (CONTINUED)
3.2 Installing the external flue
1.Place the connection piece inside the suspension bracket. This will join the single skin flue below the
bracket and the triple skin flue above the bracket which have different diameters.
2.Ensure the triple skin flue is installed as per Australian standards (see diagrams below).
Pitched roof installation
The top of the flue must be 400mm higher than the highest point of the roof. Alternatively, there must be a
minimum distance of 8 meters from any higher section of roof.
–> 40 cm
–> 40 cm
>
–8m
> 40
– cm
–> 40 cm
>
–8m
> 40
– cm
–> 40 cm
cm
–> 120
Flat roof installation (less than 5˚
pitch)
–> 120 cm
>
–8m
>
– 120 cm
The top of the flue must be 1200mm above the roofline. Alternatively, there must be a minimum distance of
8 meters from any higher section of roof.
–> 120 cm
–> 120 cm
oblica | turn Installation and User Manual
>
–8m
>
– 120 cm
page 6
3. InstallATION (CONTINUED)
3.3 Protecting the floor
•Any combustible floor beneath a fireplace must have a floor protector that extends 300mm beyond the
diameter of the firebox in all directions.
•If installed directly on combustible material, the floor protector must be made of a minimum 6mm
thick cement sheet. Non-combustible finishes can be applied to the floor protector (tiles, steel sheet,
light concrete, etc).
• If the combustible floor is installed on concrete, you can replace the combustible material with noncombustible material laid directly onto the concrete.
Floor protector laID on timber floor
Insulative board (6mm)
+ non combustible finish
Insulative board (6mm)
+ non combustible finish
Combustible
floor (eg. timber)
Combustible
floor (eg. timber)
Combustible
floor (eg. timber)
Combustible
floor (eg. timber)
Joist
Concrete
Joist
Concrete
Floor protector laId on Joist
1200mm
1200mm
80mm
Combustible
floor (eg. timber)
Combustible
floor (eg. timber)
Insulative board (6mm)
+ non combustible finish
Insulative board (6mm)
+ non combustible finish
1180mm
1180mm
80mm
Joist
Joist
oblica | turn Installation and User Manual
page 7
Floor protector lAID on CONCRETE
Combustible
floor (eg. timber)
Non combustible finish
(eg.tiles)
140mm
Combustible
floor (eg. timber)
Non combustible finish
(eg.tiles)
Concrete
140mm
1200mm
Concrete
80mm
80mm
TOP VIEW
1200mm
)
h
80mm
80mm
1180mm
)
h
3. InstallATION (CONTINUED)
C
1180mm
Floor protector
Combustible floor
(eg: Timber)
Floor protector
Combustible floor
(eg: Timber)
oblica | turn Installation and User Manual
page 8
4. OPERATION
4.1 What you should burn
• Untreated, air dried hardwood
•Split logs with a humidity content of less than 20%
4.2 Do not burn
• Trash
• Painted plastic
• Coated or preservative treated wood
• Waste or black coal
•Inflammable liquids
• Fire gels
• Moist wood with a residual humidity content of more than 20% (this may cause soothing of the chimney).
IMPORTANT:
• Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee.
• The maximum load capacity for the Turn is 10kg of wood.
• Burning only seasoned hardwood helps to protect the environment and lower emissions.
For details of a wood supplier in your area please call our office on 03 9416 0400 or email [email protected].
Warning:
• Do not use flammable liquids or aerosols to start or rekindle the fire.
• Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating.
• Do not store fuel within prescribed installation clearance distances.
• The use of some types of preservative-treated woods as a fuel can be hazardous.
oblica | turn Installation and User Manual
page 9
5. Testing
Test report No 30A-13-0024-TRP-335261-0
TESTING LABORATORY: Vipac Engineers & Scientists
Port Melbourne VIC 3207
MANUFACTURER: Skantherm GMBH
MODEL:
Turn fireplace
WORK REQUESTED: Assessment of appliance to AS/NZS 4012:1999
for determination of Power Output and Efficiency
and AS/NZS 4013:1999 for Flue Gas Emission
using hardwood fuel.
Test Dates:
29/10/2013 to 18/11/2013
INVESTIGATING OFFICERS: Christian Schmidt, Rebecca Searcy
RESULTS:
The appliance particulate emission factor established
in testing is 2.9g/kg of dry wood, within the maximum
specification of 4.0g/kg of dry wood.
CONCLUSION:
This appliance does comply with the requirements
of AS/NZS 4013:1999 for the configuration tested.
oblica | turn Installation and User Manual
page 10