Download ac-w13cg
Transcript
Air Conditioner Service Manual http://splitoff.ru/tehn-doc.html , , , . 2 MODEL: AC-W13CG Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 3 CONTENTS TECHNICAL SPECIFICATION.............................................................................................................. 4 PERFORMANCE CURVE ...................................................................................................................... 5 OUTLINE & DIMENSIONS ................................................................................................................... 6 EXPLODED VIEW & PARTLIST........................................................................................................... 7 CIRCUIT DIAGRAM .............................................................................................................................. 9 PCB FUNCTION MANUAL................................................................................................................. 10 Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 4 TECHNICAL SPECIFICATION Content Function Power supply Capacity (W) (BTU/h) Rated input (W) Rated current (A) Air flow (m3/h) Dehumidifying volume (L/h) EER(W/W) Fan type/piece Diameter-length(mm) Evaporator Row-fin distance(mm) Working area(m2) Indoor side Swing motor Input(W) Fuse (A) Working capacitor (µ F) Noise(dB(A)) Compressor Model L.R.A. (A) Throttling method Starting method Working temp. Condenser Outdoor unit Pipe-diameter Row-fin distance (mm) Working area Type-piece Noise (dB(A)) Diameter Defrosting method Motor fan speed (rpm) Output power (W) Dimension (W x H x D) (mm) Net weight (kg) Refrigerant charge AC-W13CG Cooling 1Ph 220~230V-50Hz 3200 10922 1390 6.5 430 1.6 2.4 Centrifugal fan-1 217mm x 90 Aluminum fin–copper tube 2-14 0.11 SM002 4 Controller 3.15A 3.5 µ F/450V 51 C-RV222H1AA 31 Capillary Capacity starting ≤115oC Aluminum fin-copper tube 9.52 2-1.8 0.16 Axial fan-5 57 325 Auto defrosting 970/900/850 60 570 x 380 x 590 45 R22/670g Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 5 PERFORMANCE CURVE Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 6 OUTLINES AND DIMENSIONS Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 7 EXPLODED VIEW & PART LIST Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 8 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 38 39 40 41 42 Part name Fliter net Front panel Horizontal air guider Cover of switch base plate Swing motor Drain pan Plug Slide block Knob Swing switch Mask Thermostat Insulating gasket D Main switch fan capacitor Compressor capacitor Capacitor clamp Electric box Propeller housing Chassis assembly Compressor Capillary assembly Rear insulation plate Condencer Cabinet Top cover of condensor Axial flow fan Motor support Motor Top connection plate front insulation plate Centrifugual fan insulation plate of housing Top cover of evaporator Evaporator Cross beam connecting lever Air guider Power cord Qty 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 9 CIRCUIT DIAGRAM These circuit diagrams are subject to change without notice. Please refer to the ones stuck on the machines. Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 10 PCB FUNCTION MANUAL A. Running mode 1. Cool 2. Dry 3. Fan 4. Heat 5. Auto 6. Manual operation B. Controlling contents 1. Indoor unit fan motor (high, middle and low speed) 2. Compressor 3. Sweep fan motor 4. Buzzer 5. Reversing valve 6. Electrical heater C. The parameter to be input 1. The set mode 2. The set temperature of the indoor (shorten form is Test) 3. The set speed 4. The mode of timer 5. The ambient temperature of the indoor unit (shorten form is Tin) 6. The temperature of the defrosting sensor (shorten form is Tde) 7. The sweep mode D. The basal control modes Cooling mode 1 2 3 4 5 If Tin ≥ Tset + 1oC cooling mode act, compressor run, unit fan motor and sweep fan motor run in the set speed, reversing valve stop. If Tin ≤ Tset –2oC compressor stop, unit fan motor and sweep fan motor run in the set speed. If Tset –2oC < Tin < Tset +1oC keep running in the old mode. In the cooling mode, the range of Tset is 16oC ~ 30oC and it can be set in CON. Compressor restart in 3 min after the unit stop and won’t stop during the following 6 min because Tin and Tset. Drying mode 1 2 3 4 5 6 If Tin > Tset, drying mode act. If Tin < Tset drying mode stop, compressor stop, unit fan motor run in low speed. If Tin ≤ Tset-2oC, compressor and fan motor stop. Unit fan motor run for 6 min in low speed, compressor stop, fan motor run in low speed. After 4 min, unit fan motor running low speed for 6min. Then run by this cycle. In drying mode, the range of Tset is 18oC ~30oC and it can be set in CON. The protecting functions are same as cooling mode. Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html 11 Fan mode 1 2 3 4 5 6 Unit fan motor can run in high, middle, low and auto speed, compressor stop. If the different in temperature of Tin and Tset is 2~4oC, motor run in middle speed. If the different in temperature of Tin and Tset is less than 2oC, motor run in low speed. If the different in temperature changed, fan speed will change when the new difference is more or less 1oC than the old one. In drying mode, the range of Tset is 18oC ~ 30oC and it can be set in CON. There is no protection mode in fan mode. Heating mode If Tin ≤ Tset-1oC, heating mode act, reversing, compressor run, unit fan motor run in the set speed and the condition of avoiding the cold wind, sweep fan motor run in the set mode. 2 If Tin ≥ Tset+2oC, compressor stop, reserving valve is still electric then unit fan motor run in the low speed. 3 If Tset < Tin < Tset+2oC, keep running in the old mode. 4 4-way valve stop in 4 min after unit stop. 5 When heating time exceed 45 min and Tde ≤ -8oC, defrosting mode act reversing valve and fan motor stop, compressor still run. 6 When defrosting time exceed 8 min and Tde ≥ +10oC, defrosting stop, heating mode act. Reversing valve run, fan motor run in the set speed and condition of avoiding cold wind. 7 Once heating mode act, and fan motor run in high or middle speed, electrical heater work and it won’t work when fan motor run in low speed. 8 In heating mode, the range of Tset is 16oC ~ 30oC or it can be set in CON. 9 The conditions of avoiding cold wind, fan motor run in 30sec after compressor start. 10 The protection of compressor’s delay. Compressor restart in 3min later after it stop and won’t stop in the following by Tin and Tset. 1 AUTO mode 1 If Tin ≥ Tset +1oC, cooling mode act, Tset =26oC unit fan motor run in set speed. If Tin ≤ Tset –2oC, compressor stop and fan motor run in low speed. If Tset +2oC < Tin < Tset +1oC the unit run in old mode. 2 If Tin ≤ Tset, heating mode act Tset =20oC. If Tin ≥ Tset +3oC, compressor and reversal valve stop, unit fan motor run in low speed. If Tset < Tin <Tset +3oC, keep the old mode. 3 Press Λ or Ѵ to change Tset 1 ~ 2oC more or less. Protection function They are same as the protection functions of cooling or heating mode. If Tin change, mode change first. There is no protection of compressor that compressor won’t stop in the following 6 min once it run. Others control 1 2 3 4 5 6 7 8 9 Timer Manual operation Sleep Motor speed Sweep motor Running indicate light Timer indicate light Compressor indicate light Buzzer Model No.: AC-W13CG Version: 1.0 : http://splitoff.ru/tehn-doc.html http://splitoff.ru/tehn-doc.html , , , .