Download MCW - MCR - galletti
Transcript
I MANUALE TECNICO MCW - MCR UNITÀ ACQUA-ACQUA E MOTOEVAPORANTI 5 kW - 39 kW MCW - MCR 1 INDICE 1 LA SERIE ............................................................................................... 2 2 DESCRIZIONE DELL'UNITÀ .................................................................... 3 3 CARATTERISTICHE COSTRUTTIVE ...................................................... 3-4 4 MCW MODELLI E CONFIGURAZIONI ..................................................... 5 5 MCR MODELLI E CONFIGURAZIONI ....................................................... 6 6 MCW C DATI TECNICI NOMINALI .......................................................... 7 7 MCW H DATI TECNICI NOMINALI ......................................................... 8 8 MCR C DATI TECNICI NOMINALI ........................................................... 9 9 MCW C RESE RAFFREDDAMENTO ........................................................ 1 0 1 0 MCW H RESE RAFFREDDAMENTO ....................................................... 1 1 1 1 MCW H RESE RISCALDAMENTO .......................................................... 1 2 1 2 MCR C RESE RAFFREDDAMENTO ......................................................... 1 3 1 3 LIMITI DI FUNZIONAMENTO ................................................................ 1 4 13.1 LIMITI DI FUNZIONAMENTO MCW .......................................................... 14 13.2 LIMITI DI FUNZIONAMENTO MCR ........................................................... 14 1 4 FATTORI DI CALCOLO ........................................................................... 1 5 1 5 PREVALENZA UTILE POMPE ................................................................ 1 5 1 6 PERDITE DI CARICO LATO ACQUA ....................................................... 1 6 1 7 CIRCUITO IDRAULICO LATO UTENTE ................................................... 1 7 1 8 DIMENSIONI DI INGOMBRO MCW ................................................... 18-19 1 9 DIMENSIONI DI INGOMBRO MCR ..................................................... 20-21 2 0 DRY COOLER ........................................................................................ 2 2 20.1 TABELLA ABBINAMENTO DRY COOLER ................................................. 22 2 1 CONDENSATORE REMOTO .................................................................... 2 2 21.1 TABELLA ABBINAMENTO CONDENSATORI REMOTI ............................... 22 21.2 DIMENSIONAMENTO DELLE LINEE FRIGORIFERE .................................... 23 21.3 CARATTERISTICHE TUBO REFRIGERANTE ............................................. 23 21.4 ESEMPI DI COLLEGAMENTO .................................................................. 24 21.4.1Condensatore remoto a monte della motoevaporante ........................... 24 21.4.2Condensatore remoto a valle della motoevaporante .............................. 25 2 2 POSIZIONAMENTO E SPAZI DI INSTALLAZIONE .................................. 2 6 LA SERIE I refrigeratori, le pompe di calore e le unità motoevaporanti della serie MCW ed MCR sono concepiti per impieghi in ambito residenziale e commerciale leggero, con possibili applicazioni anche al settore industriale 24 h/day. I refrigeratori MCW sono sviluppati in esecuzione completamente carenata che, grazie anche all’esclusiva adozione dei compressori di tipo scroll, conferisce all’assieme un’eccezionale silenziosità. L’ingombro contenuto, l’idraulica preassemblata ed il design gradevole, ne consentono l’installazione in ambienti non dedicati senza particolari precauzioni d’uso. La filosofia di progetto ha favorito lo sviluppo di unità d’altezza contenuta con connessioni idrauliche o frigorifere (MCR) dall’alto e piping preassemblato che riducono i tempi ed i costi dell’installazione, oltre che lo spazio tecnico occupato. L’ampia possibilità di configurazioni, sia in termini di numero di taglie presenti nella gamma, sia in termini di accessoriabilità rende la serie MCW il prodotto ideale per la riduzione dei tempi d’installazione in cantiere. L’utilizzo esclusivo di componenti di assoluta qualità nelle componenti frigorifere, idrauliche, elettriche rende le unità MCW dei refrigeratori allo stato dell’arte in termini d’efficienza, affidabilità e potenza sonora emessa. Tutte le unità sono in esecuzione monocircuito. Derivate dalla gamma di refrigeratori condensati ad acqua MCW le motoevaporanti MCR vengono proposte in esecuzione standard e silenziata per funzionamento di solo raffreddamento. Fra le numerose opzioni che completano la macchina sono disponibili condensatori remoti con ventilatori assiali, a flusso d’aria verticale o orizzontale, in versione standard e silenziata e la possibilità di recupero calore (desurriscaldatore 40%). DICHIARAZIONE DI CONFORMITÀ La Società Galletti S.p.A. con sede in Via Romagnoli 12/a Bentivoglio (Bologna) Italia, dichiara, sotto la propria responsabilità, che i refrigeratori d'acqua e pompe di calore delle serie: (vedi tabella sotto) apparecchi per impianti di condizionamento dell'aria destinati ad applicazioni per il condizionamento in ambito civile, sono conformi a quanto prescritto dalle Direttive: 2006/42/CE, 2004/108/CE, 2006/ 95/CE, 97/23/CE (PED). Tali apparecchi, che operano con fluidi del gruppo 2, secondo 97/23/CE, sono il risultato dell'assemblaggio di componenti [compressori, scambiatori di calore a piastre saldobrasate, ricevitori di liquido, tubazioni, valvole di regolazione e di sicurezza] singolarmente dotati, quando previsto, di certificazione ai sensi delle direttive vigenti: la determinazione della categoria d'appartenenza delle macchine è il frutto dell'analisi dei componenti soggetti alla PED e corrisponde alla categoria più alta fra i componenti utilizzati. Per ogni serie di macchine, la conformità dell'assieme è stata valutata da organismi notificati ed in applicazione delle procedure di valutazione (moduli) ai sensi dell'allegato II della direttiva 97/23/CE PED, come riportato nella tabella seguente: Bentivoglio li, 20/06/2013 Serie Range MCC - MCC H MCC - MCC H MCW - MCW / H MCW - MCW / H MPE - MPEH MCE - MCEH MPE - MPEH MCE - MCEH MPE - MPEH MCE - MCEH MPE - MPEH MCE - MCEH MPE - MPEH MPI MPI MPI DC MPI DC Grandezza Size 6 - 7 - 9 - 12 - 15 18 - 22 - 25 - 33 - 37 5 - 7 - 10 - 12 - 15 18 - 20 - 22 - 27 - 31 - 39 4- 5- 7- 8 9 - 10 - 11 - 13 - 15 - 18 19-20-21-23-24-26-27-28-31-32-34-35-39-40 T30 - T34 - T40 - T45 54 - 66 15 27 8 - 10 - 14 - 15 - 18 23 - 27 - 29 MFE MXE - MXE E MXE - MXE E MCP MCP 5 - 6 - 8 - 12 -13 - 16 - 17 - 20 - 23 9 - 11 - 14 - 16 19 - 21 7- 9 10-13-15-18-27-32-40-T18-T22-T24-T30 42 - 52 - 62 - 72 - 82 91/2/4 - 101/2/4 - 121/2/4 141/2/4 - 161/2/4 - 174 - 194 - 214 41-42-51-52-61-62-71-72-81-82-91-92-111-112131-132-141-142-144-161-162-164-181-182 LCE - LCE H LEW CAMPO D'APPLICAZIONE Le unità MCW-MCR sono destinate al raffreddamento-riscaldamento di acqua e soluzioni glicolate fino ad un massimo del 30% in peso, in applicazioni nell'ambito del condizionamento civile, industriale e tecnologico. Nel caso di edifici di grande superficie è possibile realizzare la climatizzazione mano a mano che si procede con la vendita/affitto dei piani/zone mediante l'installazione di una unità MCW-MCR per ogni piano in locale tecnico di ridotte dimensioni e diluendo così l'investimento nel tempo. La possibilità di mantenere all'interno l'evaporatore consente di non glicolare l'acqua dell'impianto ed inoltre consente di mantenere in un locale facilmente accessibile tutti i componenti destinati alla manutenzione ordinaria e non. Organismo Notificato Notified body 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 0425 N° certificato certificate Procedura di valutazione di conformità Conformity Compliance Module Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Modulo D1 Categoria PED PED category 0425 Modulo D1 II CE + PED 0425 Modulo D1 II CE + PED 2422/0 Galletti S.p.A. Luca Galletti I refrigeratori d'acqua e le pompe di calore sono conformi alla direttiva 97/23/CE (PED) attraverso modulo D1, approvato dall'ente terzo notificato ICIM N°0425. RG66001006 - Rev.04 2 È severamente vietata la riproduzione anche parziale di questo manuale I II I II I I II II II I II I II I I II I II Marcatura Marking CE CE + PED CE CE + PED CE CE CE + PED CE + PED CE + PED CE CE + PED CE CE + PED CE CE CE + PED CE CE + PED MCW - MCR 2 DESCRIZIONE UNITÀ 3 A- Quadro elettrico realizzato e cablato in accordo alla direttiva CEE 72/ 23, alla direttiva 89/336 sulla compatibilità elettromagnetica ed alle norme ad essa collegabili Tutte le macchine hanno connessioni idrauliche verso l’alto, contribuendo così ad una notevole limitazione degli spazi tecnici necessari all’installazione ed alla manutenzione. E’ presente a richiesta un dispositivo di controllo del flusso dell’acqua. in aggiunta a tale dispositivo è predisposta una sonda di temperatura acqua in uscita con funzione di termostato antigelo. Sono utilizzati solo scambiatori a piastre saldobrasate realizzate in acciaio inox. Controllo a microprocessore; la versione Base, presente sulle macchine standard, è costituita dal controllo Chiller. Basamento portante in lamiera zincata verniciata. La pannellatura perimetrale realizzata in lamiera zincata verniciata a forno con polveri epossipoliesteri (RAL 7035) contribuisce ad una estetica gradevole adatta ad installazioni anche in ambienti residenziali A richiesta è possibile dotare le unità di elettropompa e serbatoio di accumulo incorporati alla macchina; quest’ultimo è posto sulla mandata del circuito idraulico. Sulle unità MCW - MCR sono utilizzati solo compressori di tipo Scroll. STRUTTURA La serie MCW - MCR è realizzata con basamento portante in lamiera zincata verniciata a polveri epossipoliestere polimerizzate in forno a 180oC e pannellatura perimetrale realizzata in Peraluman (lega alluminio / magnesio 5005) per un’efficace protezione contro gli agenti corrosivi. L’Unità è completamente chiusa, ma accessibile su 3 lati con pannelli facilmente rimovibili per semplificare al massimo tutte le operazioni di manutenzione e/o controllo; tutta la manutenzione ordinaria è realizzabile dal fronte della macchina. Per il sollevamento dell’unità sono previsti dei fori ø 50 mm sul basamento in cui infilare i tubi di sollevamento e da cui avere accesso al fissaggio dei piedini antivibranti, che in ogni caso, visto l’utilizzo esclusivo di compressori Scroll, non sono indispensabili. Tutte le viterie ed i sistemi di fissaggio sono realizzati in materiali INOX non ossidabili, oppure in acciai al carbonio con trattamenti superficiali di passivazione. B- CDE- F- G- A C CARATTERISTICHE COSTRUTTIVE CIRCUITO FRIGORIFERO Il circuito frigorifero è realizzato impiegando esclusivamente componenti di primaria marca e operatori qualificati ai sensi della Direttiva 97/23 per tutte le operazioni di brasatura. Tutte le macchine sono monocircuito. B COMPRESSORI Sulle unità sono utilizzati solo compressori di tipo scroll, con protezione termica sugli avvolgimenti e riscaldatore elettrico del carter (pompa di calore) COMPONENTI FRIGORIFERI - Filtro deidratare a setaccio molecolare. - Spia di flusso con indicatore di umidità. - Valvola termostatica con equalizzazione esterna e funzione MOP integrata. - Valvola di espansione elettrica a controllo elettronico per l’ottimizzazione energetica nelle medie stagioni (accessorio). - Valvola inversione di ciclo (solo pompe di calore). - Valvole unidirezionali (solo pompa di calore). - Ricevitore di liquido (solo pompe di calore). - Pressostati alta e bassa pressione. - Valvoline schrader per controllo e/o manutenzione. D SCAMBIATORI DI CALORE LATO ACQUA Sono utilizzati solo scambiatori a piastre saldobrasate realizzate in acciaio inox austenitico AISI 304 con connessioni in AISI 304 L caratterizzato da un ridotto tenore di carbonio per facilitare le operazioni di brasatura. G F CONDENSATORE REMOTO - OPTIONAL (SOLO PER LE UNITÀ MCR) Realizzato nella geometria 25x21.65 con tubo da 3/8”, è costituito da alette in alluminio spessore 0,10 mm e tubi di rame mandrinati sulle medesime per garantire il completo contatto. Sono disponibili esecuzioni silenziate per tale componente ed anche l’opzione del controllo di condensazione mediante regolazione della velocità dei ventilatori. Il dispositivo di controllo di condensazione (optional) è parte integrante del condensatore remoto e non richiede, ad esclusione delle versioni in pompa di calore, collegamenti elettrici con la motoevaporante. Gli scambiatori a pacco alettato sono realizzati con tecnologie di scambio avanzate, alette louvered e tubi rigati internamente, per la riduzione dei volumi e quindi delle cariche di refrigerante. E SEZIONE AERAULICA - OPTIONAL (CONDENSATORI REMOTI E DRY COOLER) I ventilatori adottati sono di tipo assiale con pale a profilo alare. I ventilatori sono bilanciati staticamente e dinamicamente su due piani, dotati di griglia di protezione conforme alle EN 60335 - DIN31001-1-2 e montati con interposizione di gommini antivibranti per ridurre la propagazione di vibrazioni durante le fasi di modulazione di velocità (optional). Per contattare l'azienda, per qualsiasi informazione o segnalazione: [email protected] Per conoscere il peso di ciascuna unità, fare riferimento alla tabella del paragrafo dati tecnici nominali. I dati tecnici e dimensionali riportati nella presente documentazione possono subire variazioni orientate al miglioramento del prodotto. 3 È severamente vietata la riproduzione anche parziale di questo manuale RG66001006 - Rev.04 MCW - MCR 3 CARATTERISTICHE COSTRUTTIVE QUADRO ELETTRICO Realizzato e cablato in accordo alla direttiva CEE 73/23, alla direttiva 89/336 sulla compatibilità elettromagnetica ed alle norme ad essa collegabili. L’accesso al quadro è possibile previa rimozione del pannello esterno e l’accesso ai componenti è poi condizionato alla disconnessone dell’unità dalla rete elettrica mediante il sezionatore generale con funzioni di bloccoporta. Tutti comandi remoti sono realizzati con segnali a 24 V alimentati da un trasformatore d’isolamento posizionato nel quadro elettrico. Tutte le utenze sono protette contro il sovraccarico e contro il cortocircuito, dotate di protezione termica assolta da catene di termistori annegati negli avvolgimenti di ciascun motore elettrico. Su tutte le macchine è montato di serie il relè sequenza fasi che inibisce il funzionamento del compressore qualora la sequenza delle fasi non sia rispettata. Il grado di protezione della macchina è IP 44 ed il quadro con pannello aperto mantiene un grado di protezione IP20. In morsettiera sono presenti morsetti per la segnalazione remota di: - unità accesa/spenta (lampada a 24 V) - situazione di allarme (lampada a 24 V). MICROPROCESSORE DI CONTROLLO I refrigeratori d'acqua e le pompe di calore MCW - MCR sono completi di controllo a microprocessore: - controllo dei diversi parametri operativi mediante la tastiera predisposta sul quadro elettrico; - inserimento e disinserimento compressori per mantenere il set point impostato della temperatura acqua in ingresso allo scambiatore acqua/ refrigerante; - visualizzazione dei parametri di funzionamento; - gestione e segnalazione di allarmi - alta / bassa pressione - antigelo - flussostato - allarme pompa - gestione numero massimo avviamenti compressore; - conta-ore di funzionamento compressore; - gestione uscita seriale RS232, RS485 disponibile su richiesta. RG66001006 - Rev.04 4 È severamente vietata la riproduzione anche parziale di questo manuale MCW - MCR 4 MODELLI E CONFIGURAZIONI MCW La serie MCW è composta da 11 modelli, realizzati sia nella versione solo raffreddamento sia nella versione in pompa di calore. Le numerose opzioni costruttive sono selezionabili utilizzando il configuratore ripostato di seguito. N.B. La scelta di alcune opzioni può impedire la scelta di altre o rendere obbligatori altri campi. Contattare la Galletti S.p.A per verifica CODICE CONFIGURAZIONI / ALLESTIMENTI MACCHINA 15 campi che personalizzano l’unità alle esigenze del cliente: MCW 005 Campo Carat. Descrizione 1 Refrigerante / Alimentazione elettrica 0 R407C - 230/1/50 1 R407C - 400/3/50 + N 2 R407C- 400/3/50 con trasformatore 230V per ausiliari 2 Microprocessore / valvola espansione 0 base (Chiller) + valvola tradizionale A base (Chiller) + valvola elettronica 3 Controllo di condensazione 0 assente C modulante-pressostatico con variazione della portata acqua 4 Pompa e serbatoio 0 assente 1 solo pompa 2 pompa più serbaotio 5 Comunicazione remota 0 assente 2 RS485 6 Accessori frigoriferi 0 assente M Manometri 7 Opzioni compressore 0 assente 8 Condensatore ad acqua T condensatore maggiorato per abbinamento torre/dry cooler 9 Pannello di comando remoto 0 assente S semplificato * M a microprocessore 10 Imballo 0 standard 1 gabbia di legno 2 cassa di legno 11 Antivibranti 0 assenti G antivibranti di base in gomma 12 Accessori 0 Nessun accessorio 13 Dry cooler / condensatore remoto 0 Assente A Dry Cooler B Dry Cooler con controllo condensazione C Condensatore Remoto D Condensatore Remoto con controllo condensazione 14 Dry cooler / condensatore remoto 0 assente 1 standard flusso aria orizzontale 2 standard flusso aria verticale 3 silenziato flusso aria orizzontale 4 silenziato flusso aria verticale 15 Esecuzione 0 standard S speciale Nome commerciale della serie Refrigeratori d’acqua condensati ad acqua e pompe ei calore acquaacqua reversibili Modello Fornisce indicazioni di massima sulla resa in raffreddamento dei modelli standard 007 010 012 015 018 020 022 027 031 039 Funzionamento C H refrigeratore pompa di calore S L standard silenziata Versione * 5 In scatola Gewiss con indicatore luminoso di ON, allarme debole (es. una pompa rotta), allarme grave (es. macchina ferma) e commutatore ON-OFF. Tutto a 24 Vac sotto trasformatore d’isolamento È severamente vietata la riproduzione anche parziale di questo manuale RG66001006 - Rev.04 MCW - MCR 5 MODELLI E CONFIGURAZIONI MCR La serie MCR è composta da 11 modelli, realizzati nella versione solo raffreddamento. Le numerose opzioni costruttive sono selezionabili utilizzando il configuratore ripostato di seguito. N.B. La scelta di alcune opzioni può impedire la scelta di altre o rendere obbligatori altri campi. Contattare la Galletti S.p.A per verifica Codice Configurazioni / allestimenti macchina 15 campi che personalizzano l’unità alle esigenze del cliente: MCR 005 007 010 012 015 018 020 022 027 031 039 Nome commerciale della serie Refrigeratori d’acqua condensati ad acqua e pompe ei calore acquaacqua reversibili Modello Fornisce indicazioni di massima sulla resa in raffreddamento dei modelli standard C refrigeratore S L standard silenziata Campo Carat. Descrizione 1 Refrigerante / Alimentazione elettrica 0 R407C - 230/1/50 1 R407C - 400/3/50 + N 2 R407C- 400/3/50 con trasformatore 230V per ausiliari 2 Microprocessore / valvola espansione 0 base (Chiller) + valvola tradizionale A base (Chiller) + valvola elettronica 3 Controllo di condensazione 0 assente 4 Pompa e serbatoio 0 assente 1 solo pompa 2 pompa più serbaotio 5 Comunicazione remota 0 assente 2 RS485 6 Accessori frigoriferi 0 assente M Manometri 7 Opzioni compressore 0 Assenti 8 Condensatore ad acqua 0 assente 9 Pannello di comando remoto 0 assente S semplificato * M a microprocessore 10 Imballo 0 standard 1 gabbia di legno 2 cassa di legno 11 Antivibranti 0 assenti G antivibranti di base in gomma 12 Accessori 0 Nessun accessorio 13 Dry cooler / condensatore remoto 0 Assente A Dry Cooler B Dry Cooler con controllo condensazione C Condensatore Remoto D Condensatore Remoto con controllo condensazione 14 Dry cooler / condensatore remoto 0 assente 1 standard flusso aria orizzontale 2 standard flusso aria verticale 3 silenziato flusso aria orizzontale 4 silenziato flusso aria verticale 15 Esecuzione 0 standard S speciale Funzionamento Versione * RG66001006 - Rev.04 In scatola Gewiss con indicatore luminoso di ON, allarme debole (es. una pompa rotta), allarme grave (es. macchina ferma) e commutatore ON-OFF. Tutto a 24 Vac sotto trasformatore d’isolamento 6 È severamente vietata la riproduzione anche parziale di questo manuale MCW - MCR 6 DATI TECNICI NOMINALI MCW-C Refrigeratori d'acqua MCW - CS / CL 005 M 005 007 M 007 010 M 5,55 230-1-50 1,32 6,26 12 47 954 28 390 4 1/1 1 1 2,1 77 0,25 47 1" 830 705 453 103 138 55 47 53 45 5,5 400-3-50 + N 1,3 3,17 4,2 24 946 27 386 4 1/1 1 1 2,1 78 0,25 47 1" 830 705 453 103 138 55 47 53 45 7,04 230-1-50 1,74 8,27 15 61 1211 31 498 6 1/1 1 1 2,1 68 0,25 47 1" 830 705 453 106 141 55 47 53 45 7 400-3-50 + N 1,7 3,47 5,1 32 1203 31 494 6 1/1 1 1 2,1 69 0,25 47 1" 830 705 453 106 141 55 47 53 45 9,9 230-1-50 2,34 11,21 23,1 100 1703 27 695 5 1/1 1 1 2,6 60 0,25 47 1" 830 705 453 108 143 59 51 57 49 MCW - CS / CL 015 018 020 022 027 031 039 Potenza frigorifera resa kW Alimentazione elettrica V - ph - Hz Potenza nominale assorbita kW Corrente nominale assorbita A Corrente massima assorbita A Corrente di spunto A Portata d’acqua evaporatore l/h Perdite di carico lato evaporatore kPa Portata d’acqua condensatore l/h Perdite di carico condensatore kPa Compressori scroll / circuiti frigoriferi Nr. Evaporatore a piastre Nr. Condensatore a piastre Nr. Contenuto d’acqua circuito utilizzatore dm3 Prevalenza utile pompa (opzione) kPa Potenza elettrica pompa (opzione) kW Capacità serbatoio accumulo (opzione dm3 Connessioni idrauliche tipo GAS Dimensioni: altezza mm Dimensioni: lunghezza mm Dimensioni: profondità mm Peso unità standard kg Peso unità con pompa e serbatoio kg MCW-CS: Livello potenza sonora dB(A) MCW-CS: Livello pressione sonora dB(A) MCW-CL: Livello potenza sonora dB(A) MCW-CL: Livello pressione sonora dB(A) 14,9 17,8 20,2 26,9 31,2 38,7 3,4 8,58 13 66 2562 27 1039 4 1/1 1 1 3,1 113 0,33 92 1" 1/2 1270 812 508 121 171 61 53 59 51 3,95 9,39 14 74 3062 30 1235 6 1/1 1 1 3,1 92 0,33 92 1" 1/2 1270 812 508 125 175 61 53 59 51 4,4 11,22 16 101 3458 26 1392 5 1/1 1 1 3,6 135 0,45 92 1" 1/2 1270 812 508 167 217 61 53 60 52 21,9 400-3-50 + N 4,9 12,04 17 98 3766 29 1522 6 1/1 1 1 3,6 125 0,45 92 1" 1/2 1270 812 508 203 253 62 54 60 52 6,3 15,56 20 130 4627 26 1885 5 1/1 1 1 3,9 106 0,45 92 1" 1/2 1270 812 508 210 260 62 54 60 52 7,2 18,12 29 130 5367 29 2181 7 1/1 1 1 4,3 82 0,45 92 1" 1/2 1270 812 508 219 269 65 57 63 55 8,9 21,1 32 135 6656 28 2703 7 1/1 1 1 4,6 129 0,75 92 1" 1/2 1270 812 508 233 283 65 57 63 55 Potenza frigorifera resa kW Alimentazione elettrica V - ph - Hz Potenza nominale assorbita kW Corrente nominale assorbita A Corrente massima assorbita A Corrente di spunto A Portata d’acqua evaporatore l/h Perdite di carico lato evaporatore kPa Portata d’acqua condensatore l/h Perdite di carico condensatore kPa Compressori scroll / circuiti frigoriferi Nr. Evaporatore a piastre Nr. Condensatore a piastre Nr. Contenuto d’acqua circuito utilizzatore dm3 Prevalenza utile pompa (opzione) kPa Potenza elettrica pompa (opzione) kW Capacità serbatoio accumulo (opzione dm3 Connessioni idrauliche tipo GAS Dimensioni: altezza mm Dimensioni: lunghezza mm Dimensioni: profondità mm Peso unità standard kg Peso unità con pompa e serbatoio kg MCW-CS: Livello potenza sonora dB(A) MCW-CS: Livello pressione sonora dB(A) MCW-CL: Livello potenza sonora dB(A) MCW-CL: Livello pressione sonora dB(A) - Potenza raffreddamento: temperatura acqua all'evaporatore 12/ 7°C, temperatura al condensatore 15/30°C. - Potenza sonora rilevata secondo le norme ISO 3741 - ISO 3744 e EN 29614-1 - Pressione sonora riferita alle seguenti condizioni: in campo libero, distanza 1 metro, fattore di direzionalità pari a 2. 7 È severamente vietata la riproduzione anche parziale di questo manuale 010 012 9,9 12,2 400-3-50 + N 400-3-50 + N 2,3 2,75 4,71 6,7 7 10 46 50 1704 2098 27 31 693 849 5 7 1/1 1/1 1 1 1 1 2,6 2,6 60 124 0,25 0,33 47 92 1" 1" 1/2 830 1270 705 812 453 508 108 118 143 168 59 61 51 53 57 59 49 51 RG66001006 - Rev.04 MCW - MCR 7 DATI TECNICI NOMINALI MCW-H Pompe di calore MCW - HS / HL Potenza frigorifera resa Alimentazione elettrica Potenza nominale assorbita (in raffreddamento) Corrente nominale assorbita (in raffreddamento) Portata d’acqua evaporatore Perdite di carico lato evaporatore Portata d’acqua condensatore Perdite di carico lato condensatore Potenza termica resa Potenza nominale assorbita (in riscaldamento) Corrente nominale assorbita (in riscaldamento) Portata d’acqua condensatore Corrente massima assorbita Corrente di spunto Perdite di carico lato condensatore Compressori scroll / circuiti frigoriferi Evaporatore a piastre Condensatore a piastre Contenuto d’acqua circuito utilizzatore Prevalenza utile pompa (opzione) Potenza elettrica pompa (opzione) Capacità serbatoio accumulo (opzione) Connessioni idrauliche GAS Dimensioni: altezza Dimensioni: lunghezza Dimensioni: profondità Peso unità standard Peso unità con pompa e serbatoio MCW-HS: Livello potenza sonora MCW-HS: Livello pressione sonora MCW-HL: Livello potenza sonora MCW-HL: Livello pressione sonora kW V - ph - Hz kW A l/h kPa l/h kPa kW kW A l/h A A kPa Nr. Nr. Nr. dm3 kPa kW dm3 mm mm mm kg kg dB(A) dB(A) dB(A) dB(A) MCW - HS / HL Potenza frigorifera resa Alimentazione elettrica Potenza nominale assorbita (in raffreddamento) Corrente nominale assorbita (in raffreddamento) Portata d’acqua evaporatore Perdite di carico lato evaporatore Portata d’acqua condensatore Perdite di carico lato condensatore Potenza termica resa Potenza nominale assorbita (in riscaldamento) Corrente nominale assorbita (in riscaldamento) Portata d’acqua condensatore Perdite di carico lato condensatore Corrente massima assorbita Corrente di spunto Compressori scroll / circuiti frigoriferi Evaporatore a piastre Condensatore a piastre Contenuto d’acqua circuito utilizzatore Prevalenza utile pompa (opzione) Potenza elettrica pompa (opzione) Capacità serbatoio accumulo (opzione) Connessioni idrauliche GAS Dimensioni: altezza Dimensioni: lunghezza Dimensioni: profondità Peso unità standard Peso unità con pompa e serbatoio MCW-HS: Livello potenza sonora MCW-HS: Livello pressione sonora MCW-HL: Livello potenza sonora MCW-HL: Livello pressione sonora - kW V - ph - Hz kW A l/h kPa l/h kPa kW kW A l/h kPa A A Nr. Nr. Nr. dm3 kPa kW dm3 mm mm mm kg kg dB(A) dB(A) dB(A) dB(A) 005 M 005 007 M 007 010 M 5,3 230-1-50 1,32 6,26 911 25 376 4 6,02 1,67 8,51 1035 12 47 30 1 1 1 2,1 91 0,25 47 1" 830 705 453 106 141 55 47 53 45 5,3 400-3-50 + N 1,3 2,62 911 25 375 4 5,9 1,64 3,28 1015 4,2 24 29 1 1 1 2,1 92 0,25 47 1" 830 705 453 106 141 55 47 53 45 6,8 230-1-50 1,74 8,27 1170 29 485 6 7,75 2,19 11,51 1334 15 61 45 1 1 1 2,1 84 0,25 47 1" 830 705 453 109 144 55 47 53 45 6,8 400-3-50 + N 1,7 3,47 1169 29 482 6 7,6 2,14 4,44 1307 5,1 32 43 1 1 1 2,1 85 0,25 47 1" 830 705 453 109 144 55 47 53 45 9,6 230-1-50 2,34 11,21 1651 25 678 4 10,8 2,96 15,63 1858 23,1 100 32 1 1 1 2,6 78 0,25 47 1" 830 705 453 112 147 59 51 57 49 012 9,6 11,8 400-3-50 + N 400-3-50 + N 2,3 2,75 4,71 5,63 1651 2029 25 29 675 826 4 6 10,6 13,1 2,9 3,47 5,99 7,05 1823 2254 7 10 46 50 31 47 1 1 1 1 1 1 2,6 2,6 79 148 0,25 0,33 47 92 1" 1" 1/2 830 1270 705 812 453 508 112 123 147 173 59 61 51 53 57 59 49 51 015 018 020 022 027 031 039 14,5 17,3 20,1 26,1 30,3 37,5 3,4 7,43 2494 26 1016 4 16 4,28 8,95 2751 13 66 31 1 1 1 3,1 148 0,33 92 1" 1/2 1270 812 508 125 175 61 53 59 51 3,89 7,37 2976 28 1204 6 19,2 4,91 9,88 3303 46 14 74 1 1 1 3,1 140 0,33 92 1" 1/2 1270 812 508 132 182 61 53 59 51 4,4 9,37 3458 26 1392 5 21,6 5,5 11,89 3715 37 16 101 1 1 1 3,6 122 0,45 92 1" 1/2 1270 812 508 175 225 61 53 59 51 21,2 400-3-50 + N 4,9 10,2 3647 27 1483 6 23,59 6,2 12,63 4058 46 17 98 1 1 1 3,6 158 0,45 92 1" 1/2 1270 812 508 209 259 62 54 60 52 6,3 13,15 4489 24 1840 5 29 7,9 16,34 4989 38 20 130 1 1 1 3,9 151 0,45 92 1" 1/2 1270 812 508 221 271 62 54 60 52 7,2 15,23 5212 27 2130 7 33,6 9,1 19,04 5779 50 29 130 1 1 1 4,3 139 0,45 92 1" 1/2 1270 812 508 236 286 65 57 63 55 8,9 17,38 6450 26 2635 7 41,7 11,2 22,34 7173 18 32 135 1 1 1 4,6 149 0,75 92 1" 1/2 1270 812 508 247 297 65 57 63 55 Potenza raffreddamento: temperatura acqua all'evaporatore 12/ 7°C, temperatura al condensatore 15/30°C. Potenza riscaldamento: temperatura acqua all'evaporatore 15°C, temperatura acqua al condensatore 40/45°C. Potenza sonora rilevata secondo le norme ISO 3741 - ISO 3744 e EN 29614-1 Pressione sonora riferita alle seguenti condizioni: in campo libero, distanza 1 metro, fattore di direzionalità pari a 2. RG66001006 - Rev.04 010 8 È severamente vietata la riproduzione anche parziale di questo manuale MCW - MCR 8 DATI TECNICI NOMINALI MCR-C MCR - CS / CL Potenza frigorifera resa kW Alimentazione elettrica V - ph - Hz Potenza nominale assorbita kW Corrente nominale assorbita A Corrente massima assorbita A Corrente di spunto A Portata d’acqua evaporatore l/h Perdite di carico lato evaporatore kPa Compressori scroll / circuiti frigoriferi Nr. Evaporatore a piastre Nr. Contenuto d’acqua circuito utilizzatore dm3 Prevalenza utile pompa (opzione) kPa Potenza elettrica pompa (opzione) kW Capacità serbatoio accumulo (opzione dm3 Dimensioni: altezza mm Dimensioni: lunghezza mm Dimensioni: profondità mm MCR-CS: Livello potenza sonora dB(A) MCR-CS: Livello pressione sonora dB(A) MCR-CL: Livello potenza sonora dB(A) MCR-CL: Livello pressione sonora dB(A) MCR - CS / CL Potenza frigorifera resa kW Alimentazione elettrica V - ph - Hz Potenza nominale assorbita kW Corrente nominale assorbita A Corrente massima assorbita A Corrente di spunto A Portata d’acqua evaporatore l/h Perdite di carico lato evaporatore kPa Compressori scroll / circuiti frigoriferi Nr. Evaporatore a piastre Nr. Contenuto d’acqua circuito utilizzatore dm3 Prevalenza utile pompa (opzione) kPa Potenza elettrica pompa (opzione) kW Capacità serbatoio accumulo (opzione dm3 Dimensioni: altezza mm Dimensioni: lunghezza mm Dimensioni: profondità mm MCR-CS: Livello potenza sonora dB(A) MCR-CS: Livello pressione sonora dB(A) MCR-CL: Livello potenza sonora dB(A) MCR-CL: Livello pressione sonora dB(A) 005 M 005 007 M 007 010 M 010 012 4,8 230-1-50 1,63 7,63 12 47 825 26 1/1 1 2,1 81 0,25 47 830 705 453 55 47 53 45 4,8 400-3-50 + N 1,6 2,96 4,2 24 825 26 1/1 1 2,1 81 0,25 47 830 705 453 55 47 53 45 6,2 230-1-50 2,16 9,99 15 61 1066 30 1/1 1 2,1 72 0,25 47 830 705 453 55 47 53 45 6,2 400-3-50 + N 2,1 3,77 5,1 32 1067 30 1/1 1 2,1 72 0,25 47 830 705 453 55 47 53 45 8,6 230-1-50 2,96 13,84 23,1 100 1478 26 1/1 1 2,6 67 0,25 47 830 705 453 59 51 57 49 015 018 020 022 027 031 039 13 15,6 17,6 23,5 27,3 33,9 4,3 8,39 13 66 2236 26 1/1 1 3,1 125 0,33 92 1270 812 508 61 53 59 51 5 8,85 14 74 2683 29 1/1 1 3,1 107 0,33 92 1270 812 508 61 53 59 51 5,6 10,76 16 101 3028 26 1/1 1 3,6 145 0,45 92 1270 812 508 61 53 59 51 19,2 400-3-50 + N 6,2 11,52 17 98 3302 29 1/1 1 3,6 136 0,45 92 1270 812 508 62 54 60 52 8 15,04 20 130 4042 26 1/1 1 3,9 122 0,45 92 1270 812 508 62 54 60 52 9,1 16,96 29 130 4695 29 1/1 1 4,3 101 0,45 92 1270 812 508 62 54 60 52 11,2 19,97 32 135 5831 28 1/1 1 4,6 136 0,75 92 1270 812 508 65 57 63 55 8,6 10,76 400-3-50 + N 400-3-50 + N 2,9 3,5 5,36 6,3 7 10 46 50 1480 1851 26 30 1/1 1/1 1 1 2,6 2,6 67 133 0,25 0,33 47 92 830 1270 705 812 453 508 59 61 51 53 57 59 49 51 - Potenza raffreddamento in abbinamento con i condensatori remoti previsti dal manuale: temperatura acqua all'evaporatore 12/ 7°C , temperatura aria di condensazione 35°C - Potenza sonora rilevata secondo le norme ISO 3741 - ISO 3744 e EN 29614-1 - Pressione sonora riferita alle seguenti condizioni: in campo libero, distanza 1 metro, fattore di direzionalità pari a 2. 9 È severamente vietata la riproduzione anche parziale di questo manuale RG66001006 - Rev.04 MCW - MCR 9 RESA RAFFREDDAMENTO MCW C Legenda: Twe1 Temperatura ingresso acqua evaporatore (utilizzatore) Twe2 Temperatura uscita acqua evaporatore (utilizzatore) Twc2 Temperatura uscita acqua condensatore (dissipatore) PF Potenza frigorifera PA Potenza elettrica assorbita PD Potenza termica da dissipare MCW C MCW 005 CM MCW 005 C MCW 007 CM MCW 007 C MCW 010 CM MCW 010 C MCW 012 C RG66001006 - Rev.04 Twc2 Twe1 °C 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 °C Twe2 °C 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 PF kW 5,13 5,55 6,04 6,60 7,19 5,10 5,50 5,94 6,37 6,81 6,53 7,08 7,61 8,18 8,77 6,49 7,00 7,53 8,09 8,69 9,23 9,90 10,65 11,43 12,26 9,20 9,93 10,66 11,44 12,21 11,36 12,23 13,10 14,05 15,03 30 PA kW 1,33 1,32 1,31 1,30 1,28 1,31 1,30 1,29 1,28 1,27 1,75 1,74 1,72 1,71 1,69 1,71 1,70 1,69 1,67 1,65 2,36 2,34 2,32 2,30 2,28 2,31 2,30 2,28 2,26 2,24 2,78 2,75 2,73 2,70 2,66 PD kW 6,46 6,87 7,35 7,90 8,47 6,41 6,80 7,23 7,65 8,08 8,28 8,82 9,33 9,89 10,46 8,20 8,70 9,22 9,76 10,34 11,59 12,24 12,97 13,73 14,54 11,51 12,23 12,94 13,70 14,45 14,14 14,98 15,83 16,75 17,69 35 PA kW 1,40 1,40 1,39 1,38 1,38 1,38 1,38 1,38 1,37 1,36 1,88 1,87 1,87 1,86 1,85 1,84 1,84 1,83 1,83 1,82 2,51 2,50 2,50 2,49 2,48 2,46 2,45 2,45 2,45 2,44 2,99 2,99 2,98 2,96 2,95 PF kW 5,09 5,50 5,94 6,44 6,93 4,99 5,38 5,78 6,20 6,64 6,32 6,80 7,31 7,85 8,39 6,27 6,75 7,28 7,82 8,36 8,95 9,60 10,30 11,04 11,81 8,96 9,66 10,36 11,10 11,82 10,98 11,79 12,63 13,53 14,45 PD kW 6,49 6,90 7,33 7,82 8,31 6,37 6,76 7,16 7,57 8,00 8,20 8,67 9,18 9,71 10,24 8,11 8,59 9,11 9,65 10,18 11,46 12,10 12,80 13,53 14,29 11,42 12,11 12,81 13,55 14,26 13,97 14,78 15,61 16,49 17,40 PF kW 4,96 5,35 5,73 6,12 6,53 4,72 5,09 5,48 5,91 6,32 5,93 6,40 6,88 7,38 7,93 5,90 6,39 6,87 7,38 7,93 8,40 9,03 9,71 10,42 11,14 8,47 9,11 9,80 10,50 11,23 10,37 11,15 11,96 12,83 13,75 10 È severamente vietata la riproduzione anche parziale di questo manuale 40 PA kW 1,57 1,56 1,56 1,55 1,54 1,56 1,55 1,55 1,54 1,53 2,10 2,11 2,10 2,09 2,07 2,07 2,06 2,07 2,06 2,05 2,81 2,81 2,80 2,78 2,78 2,77 2,77 2,76 2,75 2,74 3,34 3,33 3,32 3,31 3,29 PD kW 6,53 6,91 7,29 7,67 8,07 6,28 6,64 7,03 7,45 7,85 8,03 8,51 8,98 9,47 10,00 7,97 8,45 8,94 9,44 9,98 11,21 11,84 12,51 13,20 13,92 11,24 11,88 12,56 13,25 13,97 13,71 14,48 15,28 16,14 17,04 PF kW 4,62 4,98 5,33 5,73 6,12 4,42 4,78 5,18 5,57 5,96 5,55 5,97 6,45 6,96 7,46 5,51 5,95 6,44 6,94 7,43 7,83 8,44 9,10 9,76 10,44 7,89 8,53 9,20 9,88 10,58 9,72 10,46 11,25 12,08 12,96 45 PA kW 1,76 1,75 1,75 1,74 1,74 1,75 1,74 1,74 1,73 1,73 2,36 2,35 2,34 2,33 2,31 2,33 2,33 2,32 2,31 2,30 3,16 3,15 3,14 3,13 3,12 3,12 3,12 3,11 3,10 3,09 3,71 3,71 3,71 3,70 3,69 PD kW 6,38 6,73 7,08 7,47 7,86 6,17 6,52 6,92 7,30 7,69 7,91 8,32 8,79 9,29 9,77 7,84 8,28 8,76 9,25 9,73 10,99 11,59 12,24 12,89 13,56 11,01 11,65 12,31 12,98 13,67 13,43 14,17 14,96 15,78 16,65 MCW - MCR 9 RESA RAFFREDDAMENTO MCW C Legenda: Twe1 Temperatura ingresso acqua evaporatore (utilizzatore) Twe2 Temperatura uscita acqua evaporatore (utilizzatore) Twc2 Temperatura uscita acqua condensatore (dissipatore) PF Potenza frigorifera PA Potenza elettrica assorbita PD Potenza termica da dissipare MCW C MCW 015 C MCW 018 C MCW 020 C MCW 022 C MCW 027 C MCW 031 C MCW 039 C Twc2 Twe1 °C 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 °C Twe2 °C 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 PF kW 13,79 14,93 16,09 17,33 18,59 16,48 17,84 19,22 20,64 22,06 18,69 20,15 21,63 23,20 24,81 20,34 21,92 23,61 25,39 27,24 25,01 26,95 28,97 31,10 33,37 29,04 31,27 33,60 36,05 38,65 35,99 38,76 41,66 44,70 47,98 30 PA kW 3,38 3,40 3,42 3,44 3,47 3,94 3,94 3,96 3,95 3,96 4,38 4,40 4,43 4,46 4,49 4,91 4,92 4,90 4,89 4,88 6,31 6,29 6,28 6,26 6,24 7,22 7,20 7,19 7,16 7,13 8,89 8,90 8,91 8,93 8,94 PD kW 17,17 18,33 19,51 20,77 22,06 20,42 21,78 23,18 24,59 26,02 23,07 24,55 26,06 27,66 29,30 25,25 26,84 28,51 30,28 32,12 31,32 33,24 35,25 37,36 39,61 36,26 38,47 40,79 43,21 45,78 44,88 47,66 50,57 53,63 56,92 35 PA kW 3,59 3,62 3,65 3,69 3,73 4,24 4,27 4,29 4,32 4,34 4,68 4,72 4,76 4,82 4,88 5,26 5,28 5,31 5,32 5,34 6,72 6,74 6,76 6,77 6,78 7,80 7,81 7,84 7,85 7,86 9,65 9,71 9,77 9,82 9,88 PF kW 13,41 14,46 15,58 16,73 17,93 15,91 17,15 18,41 19,73 21,06 18,15 19,51 20,92 22,39 23,88 19,63 21,13 22,70 24,38 26,12 24,22 26,04 27,95 29,27 32,07 27,96 30,05 32,24 34,53 36,93 34,59 37,16 39,88 42,75 45,74 11 PD kW 17,00 18,08 19,23 20,42 21,66 20,15 21,42 22,70 24,05 25,40 22,83 24,23 25,68 27,21 28,76 24,89 26,41 28,01 29,70 31,46 30,94 32,78 34,71 36,04 38,85 35,76 37,86 40,08 42,38 44,79 44,24 46,87 49,65 52,57 55,62 PF kW 12,64 13,64 14,71 15,82 16,97 15,00 16,17 17,35 18,59 19,87 17,13 18,42 19,78 21,19 22,64 18,50 19,93 21,43 23,03 24,70 22,83 24,57 26,40 28,33 30,35 26,36 28,33 30,43 32,63 34,94 32,69 35,16 37,75 40,48 43,36 40 PA kW 4,00 4,03 4,06 4,09 4,13 4,73 4,75 4,78 4,80 4,82 5,23 5,27 5,31 5,36 5,41 5,84 5,86 5,89 5,91 5,92 7,48 7,50 7,52 7,53 7,54 8,68 8,71 8,72 8,73 8,74 10,73 10,79 10,85 10,90 10,96 È severamente vietata la riproduzione anche parziale di questo manuale PD kW 16,64 17,67 18,77 19,91 21,10 19,73 20,92 22,13 23,39 24,69 22,36 23,69 25,09 26,55 28,05 24,34 25,79 27,32 28,94 30,62 30,31 32,07 33,92 35,86 37,89 35,04 37,04 39,15 41,36 43,68 43,42 45,95 48,60 51,38 54,32 PF kW 11,83 12,79 13,81 14,85 15,94 14,12 15,17 16,28 17,46 18,68 16,03 17,26 18,56 19,92 21,33 17,31 18,66 20,10 21,62 23,19 21,38 23,02 24,78 26,60 28,51 24,65 26,55 28,53 30,61 32,80 30,71 33,05 35,52 38,10 40,83 45 PA kW 4,45 4,47 4,51 4,54 4,57 5,27 5,30 5,33 5,35 5,37 5,86 5,89 5,93 5,98 6,03 6,48 6,50 6,54 6,55 6,58 8,32 8,35 8,37 8,38 8,40 9,70 9,72 9,73 9,75 9,75 11,96 12,01 12,07 12,13 12,19 PD kW 16,28 17,26 18,32 19,39 20,51 19,39 20,47 21,61 22,81 24,05 21,89 23,15 24,49 25,90 27,36 23,79 25,16 26,64 28,17 29,77 29,70 31,37 33,15 34,98 36,91 34,35 36,27 38,26 40,36 42,55 42,67 45,06 47,59 50,23 53,02 RG66001006 - Rev.04 MCW - MCR 10 RESA RAFFREDDAMENTO MCW H Legenda: Twe1 Temperatura ingresso acqua evaporatore(utilizzatore) Twe2 Temperatura uscita acqua evaporatore(utilizzatore) Twc2 Temperatura uscita acqua condensatore (dissipatore) PF Potenza frigorifera PA Potenza elettrica assorbita PD Potenza termica da dissipare MCW H MCW 005 HM MCW 005 H MCW 007 HM MCW 007 H MCW 010 HM MCW 010 H MCW 012 H RG66001006 - Rev.04 Twc2 Twe1 °C 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 °C Twe2 °C 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 PF kW 4,90 5,29 5,75 6,26 6,77 5,31 4,92 5,69 6,09 6,51 6,23 6,69 7,17 7,69 8,22 6,69 6,22 7,18 7,73 8,25 8,88 9,53 10,19 10,93 11,65 9,52 8,84 10,21 10,92 11,64 11,58 10,80 12,40 13,26 14,12 30 PA kW 1,33 1,33 1,33 1,32 1,32 1,31 1,31 1,31 1,31 1,30 1,80 1,80 1,80 1,79 1,79 1,76 1,75 1,76 1,76 1,75 2,40 2,39 2,39 2,38 2,38 2,34 2,34 2,34 2,33 2,33 2,88 2,88 2,87 2,86 2,85 PD kW 6,23 6,62 7,08 7,58 8,09 6,62 6,23 7,00 7,40 7,81 8,03 8,49 8,97 9,48 10,01 8,45 7,97 8,94 9,49 10,00 11,28 11,92 12,58 13,31 14,03 11,86 11,18 12,55 13,25 13,97 14,46 13,68 15,27 16,12 16,97 35 PA kW 1,48 1,48 1,48 1,48 1,47 1,47 1,47 1,47 1,47 1,46 2,01 2,01 2,01 2,00 2,00 1,97 1,98 1,98 1,97 1,97 2,67 2,67 2,67 2,67 2,66 2,63 2,63 2,63 2,63 2,63 3,20 3,20 3,20 3,20 3,18 PF kW 4,81 5,19 5,58 5,97 6,39 4,67 5,04 5,41 5,80 6,22 5,86 6,30 6,77 7,27 7,77 5,88 6,34 6,82 7,33 7,84 8,39 9,01 9,64 10,33 11,06 8,39 9,03 9,70 10,39 11,08 10,24 10,98 11,77 12,61 13,47 PD kW 6,29 6,67 7,06 7,45 7,86 6,14 6,51 6,88 7,27 7,68 7,87 8,31 8,78 9,27 9,77 7,85 8,32 8,80 9,30 9,81 11,06 11,68 12,31 13,00 13,72 11,02 11,66 12,33 13,02 13,71 13,44 14,18 14,97 15,81 16,65 PF kW 4,60 4,95 5,28 5,64 6,02 4,41 4,75 5,10 5,51 5,89 5,50 5,91 6,36 6,85 7,35 5,53 5,95 6,41 6,91 7,40 7,86 8,43 9,07 9,73 10,40 7,88 8,52 9,14 9,81 10,50 9,64 10,35 11,10 11,92 12,73 12 È severamente vietata la riproduzione anche parziale di questo manuale 40 PA kW 1,66 1,66 1,66 1,66 1,65 1,65 1,65 1,65 1,65 1,64 2,25 2,26 2,25 2,24 2,22 2,21 2,22 2,22 2,22 2,20 3,00 3,00 2,99 2,98 2,98 2,96 2,95 2,96 2,96 2,95 3,56 3,57 3,56 3,56 3,56 PD kW 6,26 6,61 6,94 7,30 7,67 6,06 6,40 6,75 7,16 7,53 7,75 8,17 8,61 9,09 9,57 7,74 8,17 8,63 9,13 9,60 10,86 11,43 12,06 12,71 13,38 10,84 11,47 12,10 12,77 13,45 13,20 13,92 14,66 15,48 16,29 PF kW 4,27 4,58 4,92 5,28 5,66 4,11 4,44 4,80 5,18 5,55 5,12 5,51 5,96 6,42 6,90 5,12 5,54 5,99 6,45 6,92 7,30 7,86 8,46 9,08 9,73 7,34 7,94 8,53 9,19 9,83 9,00 9,67 10,39 11,16 11,99 45 PA kW 1,85 1,85 1,85 1,84 1,84 1,85 1,86 1,86 1,84 1,84 2,50 2,50 2,49 2,47 2,45 2,49 2,49 2,49 2,48 2,48 3,37 3,38 3,36 3,36 3,34 3,32 3,32 3,32 3,31 3,31 3,96 3,98 3,98 3,98 3,97 PD kW 6,12 6,43 6,77 7,12 7,50 5,96 6,30 6,66 7,02 7,39 7,62 8,01 8,45 8,89 9,35 7,61 8,03 8,48 8,93 9,40 10,67 11,24 11,82 12,44 13,07 10,66 11,26 11,85 12,50 13,14 12,96 13,65 14,37 15,14 15,96 MCW - MCR 10 RESA RAFFREDDAMENTO MCW H Legenda: Twe1 Temperatura ingresso acqua evaporatore(utilizzatore) Twe2 Temperatura uscita acqua evaporatore(utilizzatore) Twc2 Temperatura uscita acqua condensatore (dissipatore) PF Potenza frigorifera PA Potenza elettrica assorbita PD Potenza termica da dissipare MCW H MCW 015 H MCW 018 H MCW 020 H MCW 022 H MCW 027 H MCW 031 H MCW 039 H Twc2 Twe1 °C 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 °C Twe2 °C 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 PF kW 14,34 13,34 15,43 16,56 17,71 16,96 15,73 18,21 19,48 20,75 19,84 18,51 21,26 22,73 24,23 20,83 19,35 22,34 23,95 25,64 25,74 23,98 27,60 29,53 31,58 29,62 27,60 31,74 33,96 36,29 36,55 34,05 39,16 41,90 44,81 30 PA kW 3,47 3,43 3,52 3,56 3,61 4,06 4,02 4,09 4,12 4,15 4,53 4,47 4,58 4,64 4,71 5,10 5,06 5,13 5,15 5,18 6,49 6,45 6,52 6,55 6,57 7,55 7,51 7,58 7,61 7,64 9,40 9,32 9,47 9,56 9,64 PD kW 17,81 16,77 18,95 20,12 21,32 21,02 19,75 22,30 23,60 24,90 24,37 22,98 25,84 27,37 28,94 25,93 24,41 27,47 29,10 30,82 32,23 30,43 34,12 36,08 38,15 37,17 35,11 39,32 41,57 43,93 45,95 43,37 48,63 51,46 54,45 35 PA kW 3,81 3,85 3,89 3,94 3,98 4,48 4,51 4,54 4,58 4,60 4,99 5,04 5,09 5,15 5,22 5,60 5,64 5,68 5,71 5,73 7,17 7,20 7,24 7,21 7,29 8,35 8,38 8,42 8,45 8,48 10,34 10,42 10,50 10,59 10,67 PF kW 12,60 13,59 14,63 15,71 16,82 14,89 16,02 17,18 18,39 19,63 17,52 18,81 20,18 21,59 23,04 18,32 19,73 21,16 22,69 24,33 22,67 24,37 26,15 28,02 29,99 26,10 28,03 30,07 32,19 34,42 32,29 34,65 37,15 39,79 42,56 13 PD kW 16,41 17,44 18,52 19,65 20,80 19,37 20,53 21,72 22,97 24,23 22,51 23,85 25,27 26,74 28,26 23,92 25,37 26,84 28,40 30,06 29,84 31,57 33,39 35,23 37,28 34,45 36,41 38,49 40,64 42,90 42,63 45,07 47,65 50,38 53,23 PF kW 11,84 12,79 13,78 14,81 15,87 14,05 15,09 16,16 17,31 18,50 16,48 17,71 19,02 20,37 21,76 17,21 18,54 19,93 21,40 22,93 21,32 22,91 24,63 26,41 28,27 24,54 26,36 28,30 30,31 32,45 30,41 32,68 35,06 37,58 40,24 40 PA kW 4,24 4,28 4,32 4,36 4,40 4,99 5,02 5,05 5,09 5,12 5,57 5,62 5,67 5,73 5,80 6,21 6,25 6,29 6,32 6,36 7,96 8,00 8,04 8,07 8,09 9,29 9,34 9,36 9,40 9,42 11,49 11,57 11,66 11,74 11,81 È severamente vietata la riproduzione anche parziale di questo manuale PD kW 16,08 17,07 18,10 19,17 20,27 19,04 20,11 21,21 22,40 23,62 22,05 23,33 24,69 26,10 27,56 23,42 24,79 26,22 27,72 29,29 29,28 30,91 32,67 34,48 36,36 33,83 35,70 37,66 39,71 41,87 41,90 44,25 46,72 49,32 52,05 PF kW 11,06 11,95 12,90 13,89 14,89 13,18 14,15 15,17 16,27 17,37 15,35 16,53 17,78 19,10 20,42 16,04 17,29 18,59 19,97 21,46 19,86 21,41 23,00 24,67 26,46 22,83 24,57 26,43 28,33 30,34 28,48 30,64 32,90 35,29 37,80 45 PA kW 4,70 4,74 4,78 4,82 4,87 5,55 5,59 5,62 5,65 5,69 6,24 6,28 6,34 6,40 6,47 6,88 6,92 6,97 7,00 7,04 8,86 8,89 8,93 8,97 8,99 10,39 10,42 10,44 10,47 10,49 12,80 12,88 12,96 13,03 13,12 PD kW 15,76 16,69 17,68 18,71 19,76 18,73 19,74 20,79 21,92 23,06 21,59 22,81 24,12 25,50 26,89 22,92 24,21 25,56 26,97 28,50 28,72 30,30 31,93 33,64 35,45 33,22 34,99 36,87 38,80 40,83 41,28 43,52 45,86 48,32 50,92 RG66001006 - Rev.04 MCW - MCR 11 RESA RISCALDAMENTO MCW H Legenda: Twc1 Temperatura ingresso acqua condensatore (utilizzatore) Twc2 Temperatura uscita acqua condensatore (utilizzatore) Twe2 Temperatura uscita acqua evaporatore (dissipatore) PT Potenza termica in riscaldamento PA Potenza elettrica assorbita MCW H MCW 005 HM MCW 005 H MCW 007 HM MCW 007 H MCW 010 HM MCW 010 H MCW 012 H RG66001006 - Rev.04 Twe2 Twc1 Twc2 °C °C 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 8°C PT kW 5,99 5,88 5,70 5,55 5,83 5,70 5,58 5,45 7,74 7,54 7,35 7,14 7,57 7,37 7,20 7,01 10,79 10,51 10,25 10,02 10,54 10,29 10,03 9,77 13,04 12,72 12,41 12,12 9°C PA kW 1,34 1,50 1,67 1,84 1,30 1,46 1,64 1,84 1,78 1,98 2,20 2,41 1,69 1,90 2,13 2,39 2,35 2,64 2,96 3,35 2,29 2,57 2,90 3,25 2,79 3,11 3,46 3,88 PT kW 6,16 6,03 5,86 5,69 6,00 5,86 5,74 5,59 7,96 7,75 7,55 7,33 7,78 7,58 7,40 7,21 11,09 10,81 10,53 10,27 10,84 10,57 10,30 10,04 13,40 13,07 12,74 12,45 10°C PA kW 1,34 1,50 1,67 1,84 1,31 1,47 1,65 1,84 1,78 1,98 2,19 2,40 1,70 1,90 2,14 2,39 2,35 2,63 2,96 3,35 2,29 2,58 2,90 3,26 2,79 3,11 3,47 3,89 PT kW 6,34 6,19 6,02 5,84 6,18 6,05 5,90 5,74 8,19 7,97 7,75 7,54 8,01 7,81 7,60 7,41 11,40 11,12 10,80 10,55 11,16 10,89 10,60 10,31 13,77 13,43 13,10 12,77 11°C PA kW 1,34 1,50 1,67 1,84 1,30 1,46 1,64 1,84 1,77 1,98 2,19 2,39 1,69 1,90 2,14 2,39 2,35 2,63 2,96 3,35 2,29 2,58 2,90 3,24 2,79 3,10 3,47 3,88 14 È severamente vietata la riproduzione anche parziale di questo manuale PT kW 6,52 6,36 6,18 6,01 6,35 6,22 6,07 5,91 8,42 8,21 7,98 7,76 8,24 8,04 7,81 7,61 11,74 11,42 11,11 10,83 11,47 11,18 10,89 10,58 14,17 13,82 13,46 13,11 PA kW 1,34 1,50 1,67 1,83 1,30 1,46 1,63 1,83 1,77 1,98 2,18 2,38 1,69 1,90 2,13 2,38 2,35 2,63 2,96 3,34 2,29 2,58 2,89 3,24 2,79 3,10 3,47 3,88 12°C PT kW 6,71 6,53 6,33 6,16 6,55 6,39 6,22 6,05 8,65 8,44 8,20 7,99 8,47 8,26 8,03 7,81 12,08 11,73 11,40 11,11 11,78 11,49 11,18 10,84 14,56 14,20 13,84 13,48 PA kW 1,33 1,50 1,67 1,83 1,30 1,46 1,64 1,83 1,76 1,97 2,17 2,37 1,69 1,90 2,12 2,37 2,34 2,63 2,95 3,33 2,29 2,57 2,89 3,24 2,78 3,10 3,46 3,89 MCW - MCR 11 RESA RISCALDAMENTO MCW H Legenda: Twc1 Temperatura ingresso acqua condensatore (utilizzatore) Twc2 Temperatura uscita acqua condensatore (utilizzatore) Twe2 Temperatura uscita acqua evaporatore (dissipatore) PT Potenza termica in riscaldamento PA Potenza elettrica assorbita MCW H MCW 015 H MCW 018 H MCW 020 H MCW 022 H MCW 027 H MCW 031 H MCW 039 H Twe2 Twc1 Twc2 °C °C 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 35 30 40 35 45 40 50 45 8°C PT kW 15,91 15,49 15,08 14,67 19,13 18,63 18,18 17,84 21,52 20,97 20,40 19,86 23,58 22,94 22,31 21,65 28,99 28,22 27,43 26,67 33,59 32,70 31,84 31,00 41,38 40,41 39,48 38,64 PA kW 3,45 3,82 4,24 4,69 3,95 4,39 4,89 5,42 4,38 4,88 5,46 6,11 5,02 5,56 6,16 6,83 6,38 7,08 7,88 8,77 7,31 8,13 9,07 10,14 9,01 10,00 11,12 12,40 9°C PT kW 16,42 15,97 15,53 15,11 19,68 19,14 18,68 18,30 22,16 21,58 21,00 20,42 24,27 23,62 22,92 22,25 29,84 29,04 28,21 27,39 34,55 33,64 32,73 31,83 42,59 41,56 40,58 39,65 10°C PA kW 3,47 3,84 4,26 4,71 3,96 4,40 4,90 5,44 4,40 4,90 5,48 6,14 5,04 5,58 6,19 6,85 6,39 7,10 7,89 8,79 7,32 8,14 9,08 10,14 9,05 10,04 11,17 12,43 15 PT kW 16,93 16,46 16,00 15,55 20,24 19,69 19,20 18,80 22,82 22,21 21,60 20,99 25,00 24,30 23,59 22,87 30,71 29,85 29,00 28,12 35,55 34,58 33,60 32,63 43,83 42,76 41,70 40,69 PA kW 3,49 3,86 4,28 4,73 3,98 4,42 4,91 5,45 4,43 4,93 5,50 6,17 5,05 5,59 6,20 6,87 6,40 7,11 7,90 8,80 7,33 8,16 9,10 10,16 9,08 10,07 11,20 12,46 È severamente vietata la riproduzione anche parziale di questo manuale 11°C PT kW 17,44 16,95 16,47 15,99 20,83 20,24 19,72 19,27 23,47 22,84 22,23 21,62 25,73 25,02 24,24 23,49 31,60 30,72 29,79 28,88 36,54 35,54 34,52 33,49 45,09 43,95 42,85 41,78 PA kW 3,51 3,88 4,29 4,76 3,99 4,44 4,92 5,47 4,46 4,96 5,53 6,19 5,07 5,61 6,22 6,89 6,41 7,12 7,92 8,81 7,35 8,18 9,11 10,16 9,12 10,11 11,23 12,49 12°C PT kW 17,97 17,44 16,94 16,46 21,42 20,81 20,26 19,77 24,16 23,51 22,88 22,26 26,49 25,72 24,93 24,12 32,50 31,56 30,62 29,66 37,59 36,55 35,45 34,37 46,39 45,20 44,03 42,89 PA kW 3,53 3,90 4,31 4,77 4,00 4,44 4,94 5,48 4,48 4,99 5,57 6,23 5,08 5,62 6,24 6,90 6,43 7,14 7,93 8,83 7,36 8,19 9,12 10,16 9,15 10,15 11,27 12,51 RG66001006 - Rev.04 MCW - MCR 12 RESA RAFFREDDAMENTO MCR C Legenda: Twe1 Temperatura ingresso acqua evaporatore (utilizzatore) Twe2 Temperatura uscita acqua evaporatore (utilizzatore) Twc2 Temperatura uscita acqua condensatore (dissipatore) PF Potenza frigorifera PA Potenza elettrica assorbita PD Potenza termica da dissipare MCR C MCR 005 CM MCR 005 C MCR 007 CM MCR 007 C MCR 010 CM MCR 010 C MCR 012 C RG66001006 - Rev.04 Twc2 Twe1 °C 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 °C Twe2 °C 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 PF kW 4,82 5,23 5,69 6,23 6,78 5,03 5,43 5,85 6,27 6,72 6,85 7,40 7,52 8,02 8,52 6,79 7,34 7,52 8,02 8,54 9,23 9,92 10,65 11,45 12,26 9,10 9,82 10,57 11,32 12,10 11,76 12,65 12,92 13,74 14,61 25 PA kW 1,28 1,27 1,26 1,24 1,23 1,25 1,24 1,23 1,22 1,21 1,58 1,57 1,75 1,76 1,78 1,52 1,51 1,69 1,71 1,72 2,28 2,26 2,25 2,22 2,20 2,22 2,21 2,19 2,17 2,15 2,59 2,57 2,84 2,88 2,90 PD kW 6,10 6,50 6,95 7,47 8,01 6,28 6,67 7,08 7,49 7,93 8,43 8,97 9,27 9,78 10,30 8,31 8,85 9,21 9,73 10,26 11,51 12,18 12,90 13,67 14,46 11,32 12,03 12,76 13,49 14,25 14,35 15,22 15,76 16,62 17,51 PF kW 4,74 5,09 5,45 5,81 6,14 4,75 5,10 5,46 5,83 6,21 6,20 6,63 7,08 7,57 8,06 6,20 6,64 7,10 7,58 8,07 8,60 9,18 9,78 10,44 11,10 8,54 9,17 9,80 10,43 11,08 10,74 11,48 12,23 13,01 13,83 30 PA kW 1,44 1,46 1,47 1,47 1,48 1,42 1,43 1,44 1,45 1,46 1,91 1,93 1,95 1,96 1,98 1,84 1,87 1,89 1,91 1,93 2,61 2,64 2,66 2,68 2,70 2,55 2,58 2,61 2,63 2,66 3,11 3,14 3,18 3,21 3,24 PD kW 6,18 6,55 6,92 7,28 7,62 6,17 6,53 6,90 7,28 7,67 8,11 8,56 9,03 9,53 10,04 8,04 8,51 8,99 9,49 10,00 11,21 11,82 12,44 13,12 13,80 11,09 11,75 12,41 13,06 13,74 13,85 14,62 15,41 16,22 17,07 PF kW 4,49 4,80 5,10 5,44 5,79 4,46 4,80 5,15 5,52 5,88 5,81 6,20 6,64 7,11 7,59 5,78 6,20 6,64 7,10 7,55 8,03 8,60 9,19 9,79 10,41 8,02 8,60 9,21 9,81 10,44 10,07 10,76 11,48 12,24 13,00 35 PA kW 1,62 1,63 1,64 1,66 1,66 1,59 1,60 1,62 1,63 1,64 2,14 2,16 2,17 2,18 2,19 2,07 2,10 2,12 2,14 2,16 2,93 2,96 2,98 3,01 3,03 2,87 2,90 2,93 2,96 2,98 3,46 3,50 3,54 3,59 3,63 PD kW 6,11 6,43 6,74 7,10 7,45 6,05 6,40 6,77 7,15 7,52 7,95 8,36 8,81 9,29 9,78 7,85 8,30 8,76 9,24 9,71 10,96 11,56 12,17 12,80 13,44 10,89 11,50 12,14 12,77 13,42 13,53 14,26 15,02 15,83 16,63 PF kW 4,16 4,46 4,77 5,11 5,42 4,16 4,49 4,82 5,17 5,50 5,40 5,77 6,19 6,65 7,12 5,36 5,76 6,17 6,59 7,02 7,44 7,99 8,53 9,12 9,70 7,45 8,01 8,58 9,16 9,74 9,37 10,01 10,68 11,40 12,13 16 È severamente vietata la riproduzione anche parziale di questo manuale 40 PA kW 1,80 1,81 1,82 1,83 1,84 1,79 1,81 1,82 1,83 1,84 2,36 2,37 2,38 2,39 2,39 2,32 2,35 2,38 2,40 2,42 3,31 3,34 3,36 3,39 3,42 3,23 3,27 3,30 3,32 3,35 3,86 3,91 3,96 4,01 4,07 PD kW 5,96 6,27 6,59 6,94 7,26 5,95 6,30 6,64 7,00 7,34 7,76 8,14 8,57 9,04 9,51 7,68 8,11 8,55 8,99 9,44 10,75 11,33 11,89 12,51 13,12 10,68 11,28 11,88 12,48 13,09 13,23 13,92 14,64 15,41 16,20 PF kW 3,85 4,14 4,43 4,75 5,06 3,85 4,16 4,47 4,78 5,08 5,00 5,35 5,76 6,19 6,64 4,92 5,30 5,71 6,12 6,52 6,85 7,36 7,88 8,42 8,98 6,85 7,37 7,91 8,46 9,01 8,66 9,25 9,89 10,56 11,26 45 PA kW 1,98 1,99 2,00 2,00 2,01 2,01 2,03 2,04 2,05 2,05 2,58 2,90 2,59 2,59 2,59 2,60 2,63 2,64 2,66 2,67 3,76 3,78 3,82 3,83 3,84 3,64 3,68 3,47 3,72 3,74 4,32 4,36 4,40 4,45 4,49 PD kW 5,83 6,13 6,43 6,75 7,07 5,86 6,19 6,51 6,83 7,13 7,58 8,25 8,35 8,78 9,23 7,52 7,93 8,35 8,78 9,19 10,61 11,14 11,70 12,25 12,82 10,49 11,05 11,38 12,18 12,75 12,98 13,61 14,29 15,01 15,75 MCW - MCR 12 RESA RAFFREDDAMENTO MCR C Legenda: Twe1 Temperatura ingresso acqua evaporatore (utilizzatore) Twe2 Temperatura uscita acqua evaporatore (utilizzatore) Twc2 Temperatura uscita acqua condensatore (dissipatore) PF Potenza frigorifera PA Potenza elettrica assorbita PD Potenza termica da dissipare MCR C MCR 015 C MCR 018 C MCR 020 C MCR 022 C MCR 027 C MCR 031 C MCR 039 C Twc2 Twe1 °C 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 10 12 14 16 18 °C Twe2 °C 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 5 7 9 11 13 PF kW 13,72 14,82 15,97 17,22 18,45 16,87 18,24 19,69 19,98 21,18 18,78 20,20 21,69 23,29 23,83 20,77 22,43 24,13 24,64 26,23 25,10 27,08 29,10 31,22 32,04 29,97 32,24 32,91 35,05 37,24 35,89 38,61 41,57 44,59 45,83 25 PA kW 3,37 3,39 3,41 3,44 3,47 3,75 3,75 3,76 4,18 4,26 4,29 4,31 4,33 4,36 4,82 4,73 4,73 4,72 5,22 5,32 6,20 6,19 6,17 6,16 6,75 6,75 6,73 7,44 7,56 7,68 8,71 8,73 8,74 8,75 9,56 PD kW 17,09 18,21 19,38 20,66 21,92 20,62 21,99 23,45 24,16 25,44 23,07 24,51 26,02 27,65 28,65 25,50 27,16 28,85 29,86 31,55 31,30 33,27 35,27 37,38 38,79 36,72 38,97 40,35 42,61 44,92 44,60 47,34 50,31 53,34 55,39 PF kW 12,88 13,84 14,83 15,83 16,86 15,52 16,60 17,71 18,82 19,96 17,53 18,73 19,98 21,27 22,59 19,09 20,47 21,89 23,27 24,80 23,37 25,01 26,73 28,46 30,30 27,27 29,15 31,10 33,06 35,40 33,62 35,94 38,34 40,89 46,44 30 PA kW 3,80 3,87 3,95 4,03 4,11 4,41 4,49 4,56 4,64 4,73 4,94 5,02 5,13 5,23 5,34 5,52 5,59 5,64 5,79 5,88 7,10 7,20 7,30 7,39 7,50 8,05 8,17 8,29 8,41 8,55 9,91 10,09 10,24 10,42 10,60 PD kW 16,68 17,71 18,78 19,86 20,97 19,93 21,09 22,27 23,46 24,69 22,47 23,75 25,11 26,50 27,93 24,61 26,06 27,53 29,06 30,68 30,47 32,21 34,03 35,85 37,80 35,32 37,32 39,39 41,47 43,95 43,53 46,03 48,58 51,31 57,04 17 PF kW 12,26 13,00 13,94 14,89 15,85 14,60 15,60 16,62 17,70 18,75 16,48 17,60 18,79 20,06 21,27 17,94 19,20 20,52 21,90 23,28 21,94 23,50 25,08 26,72 28,44 25,59 27,30 29,12 31,01 32,98 31,66 33,90 36,14 38,55 41,04 35 PA kW 4,14 4,30 4,39 4,47 4,55 4,91 5,00 5,08 5,17 5,26 5,51 5,60 5,72 5,82 5,95 6,11 6,20 6,30 6,40 6,51 7,90 8,00 8,12 8,22 8,34 8,98 9,10 9,24 9,37 9,50 11,03 11,20 11,38 11,57 11,77 PD kW 16,40 17,30 18,33 19,36 20,40 19,51 20,60 21,70 22,87 24,01 21,99 23,20 24,51 25,88 27,22 24,05 25,40 26,82 28,30 29,79 29,84 31,50 33,20 34,94 36,78 34,57 36,40 38,36 40,38 42,48 42,69 45,10 47,52 50,12 52,81 PF kW 11,28 12,14 13,02 13,91 14,82 13,67 14,60 15,57 16,58 17,57 15,32 16,37 17,52 18,73 19,93 16,70 17,86 19,07 20,34 21,70 20,42 21,87 23,36 24,94 26,52 23,75 25,41 27,03 28,79 30,59 29,64 31,73 33,92 36,13 38,52 È severamente vietata la riproduzione anche parziale di questo manuale 40 PA kW 4,70 4,78 4,87 4,95 5,04 5,48 5,57 5,66 5,76 5,85 6,18 6,28 6,39 6,51 6,65 6,77 6,87 6,98 7,10 7,20 8,79 8,91 9,03 9,15 9,26 10,04 10,16 10,32 10,45 10,58 12,31 12,50 12,68 12,86 13,09 PD kW 15,98 16,92 17,89 18,86 19,86 19,15 20,17 21,23 22,34 23,42 21,50 22,65 23,91 25,24 26,58 23,47 24,73 26,05 27,44 28,90 29,21 30,78 32,39 34,09 35,78 33,79 35,57 37,35 39,24 41,17 41,95 44,23 46,60 48,99 51,61 PF kW 10,47 11,26 12,09 12,93 14,00 12,73 13,63 14,55 15,47 16,37 14,14 15,11 16,19 17,36 18,51 15,38 16,50 17,63 18,76 20,01 18,84 20,17 21,57 23,02 24,50 21,84 23,36 24,92 26,57 28,26 27,64 29,50 31,58 33,69 35,90 45 PA kW 5,21 5,29 5,39 5,48 5,47 6,10 6,19 6,28 6,36 6,44 6,93 7,04 7,16 7,28 7,42 7,50 7,60 7,72 7,83 7,93 9,80 9,92 10,04 10,16 10,28 11,23 11,35 11,48 11,58 11,68 13,76 13,96 14,12 14,31 14,49 PD kW 15,68 16,55 17,48 18,41 19,47 18,83 19,82 20,83 21,83 22,81 21,07 22,15 23,35 24,64 25,93 22,88 24,10 25,35 26,59 27,94 28,64 30,09 31,61 33,18 34,78 33,07 34,71 36,40 38,15 39,94 41,40 43,46 45,70 48,00 50,39 RG66001006 - Rev.04 MCW - MCR 13 LIMITI DI FUNZIONAMENTO 13.1 LIMITI DI FUNZIONAMENTO MCW I limiti indicati nel diagramma si riferiscono ad un uso continuativo della macchina, senza impiego di acqua glicolata nel circuito dissipatore. Per il funzionamento in raffreddamento fare riferimento al paragrafo precedente. Tensione di alimentazione: ± 10% rispetto al valore nominale I limiti di funzionamento riportati nei diagrammi sono validi per salti termici dell’acqua da 3 a 8°C Legenda: Temperatura acqua in uscita dall'evaporatore Twe2 Twc2 Temperatura acqua in uscita dal condenstore Twc2 (°C) 45 40 Twe2 (°C) 13 9 30 Unità standard 10 12 Standard units 20 25 Twe1 (°C) 13.2 LIMITI DI FUNZIONAMENTO MCR Tensione di alimentazione: ± 10% rispetto al valore nominale I limiti di funzionamento riportati nei diagrammi sono validi per salti termici dell’acqua da 3 a 8°C Legenda: Temperatura esterna a bulbo secco Tbs1 Tw2 Temperatura uscita acqua 5 25 40 43 Twc2 (°C) FUNZIONAMENTO IN RAFFREDDAMENTO Per operare con temperature dell'acqua al condensatore inferiori ai 25 °C è indispensabile adottare (optional) il dispositivo per il controllo di condensazione: Il controllo mediante modulazione della portata acqua con una valvola a 2 vie di tipo pressostatico o, per i modelli di taglia superiore, pilotata diretamente dal microprocessore di bordo. Nel caso sia necessario operare con temperature maggiori di 43°C e/o raffreddare fluidi a temperature Twe2 maggiori di 13°C, si deve ricorrere alle versioni ad R134a disponibili su richiesta, che elevano il limite di temperature acqua all'uscita del condensatore a + 60°C in funzionamento continuativo. FUNZIONAMENTO IN RAFFREDDAMENTO Per operare con temperature dell'aria inferiori ai 20 °C è indispensabile adottare (optional) il dispositivo per il controllo di condensazione: Il controllo mediante modulazione della velocità dei ventilatori con un regolatore a taglio di fase permette il funzionamento in fase di raffreddamento con temperature dell'aria esterna Tbs1 fino a -15 °C . FUNZIONAMENTO IN RISCALDAMENTO 45 40 42 30 Tbs1 (°C) 20 Con controllo di condensazione 10 0 Le unità in pompa di calore sono realizzate prevedendo lo scambiatore ad acqua collegato in controcorrente nel funzionamento in raffreddamento. Per esecuzioni che prevedono la produzione di acqua a temperatura Twc2 superiori ai valori indicati sono disponibili (optional) sia l’esclusiva inversione di ciclo anche lato acqua che mantiene sempre il flusso in controcorrente, sia l’esecuzione ad R134a disponibile a richiesta. L’R134a è un fluido altobollente caratterizzato da basse pressioni d’esercizio, che quindi richiede compressori con cilindrata maggiore (+60%) rispetto alle versioni ad R407C a parità di portata in massa elaborata. RG66001006 - Rev.04 -15 3 5 7 9 11 13 15 Tw2 (°C) 18 È severamente vietata la riproduzione anche parziale di questo manuale 17 19 MCW - MCR 14 FATTORI DI CALCOLO Salto termico acqua diverso da 5 Salto termico acqua Fattore correzione potenza resa Fattore correzione potenza assorbita Fattore correzione portata acqua Fattore correzione perdita di carico 3 0,975 1 1,63 2,64 4 0,99 1 1,24 1,53 5 1 1 1 1 6 1,015 1 0,85 0,72 7 1,03 1 0,74 0,54 30% -10°C -18°C 0,989 1,14 1,585 40% -15°C -24°C 0,983 1,199 1,86 30% -10°C -18°C 0,971 1,07 1,532 40% -15°C -24°C 0,96 1,098 1,777 8 1,04 1 0,65 0,42 Funzionamento con miscele acqua-glicole etilenico Percentuale glicole Temperatura minima acqua prodotta Temperatura congelamento miscela (°C) Fattore correzione potenza resa Fattore correzione portata acqua Fattore correzione perdita di carico 0% 5°C 0°C 1 1 1 10% 2°C -4°C 0,998 1,047 1,157 20% -5°C -14°C 0,994 1,094 1,352 Funzionamento con miscele acqua-glicole PROPILENICO Percentuale glicole Temperatura minima acqua prodotta Temperatura congelamento miscela (°C) Fattore correzione potenza resa Fattore correzione portata acqua Fattore correzione perdita di carico 0% 5°C 0°C 1 1 1 10% 2°C -4°C 0,996 1,022 1,111 20% -5°C -14°C 0,985 1,043 1,307 FATTORI DI INCROSTAZIONE Fattori di incrostazione (m2 °C / W) Fattore correzione potenza resa Fattore correzione potenza assorbita 15 4,4 x 10 -5 8,8 x 10 -5 17,6 x 10 -5 0,97 0,94 0,93 0,99 0,99 0,98 0 1 1 PREVALENZA UTILE POMPE Nel diagramma sottoriportato sono indicate le prevalenze utili delle pompe, al netto delle perdite di carico dello scambiatore lato utente, valide sia per unità MCW sia MCR. Pu (kPa) 012 012 015 018 020/022 027 031 039 160 140 120 005 007 010 100 80 60 40 20 1,0 2,0 3,0 4,0 Qw (m3/h) 19 5,0 6,0 È severamente vietata la riproduzione anche parziale di questo manuale 7,0 8,0 RG66001006 - Rev.04 MCW - MCR 16 PERDITE DI CARICO LATO ACQUA Il diagramma riporta le perdite di carico lato acqua pw in funzione della portata acqua Qw, riferite ad una temperatura media dell'acqua di 10°C SCAMBIATORE DI CALORE LATO UTILIZZATORE MCW - MCR Dpw (kPa) 140 005 007 010 012 015 018 020 022 120 100 027 80 60 031 40 039 20 0 0 1000 2000 3000 4000 Qw (l/h) 5000 6000 7000 8000 9000 SCAMBIATORE DI CALORE LATO DISSIPATORE (SOLO MCW) Dpw (kPa) 005 140 010 007 012 015 018 020 - 022 027 031 039 120 100 80 60 40 20 0 0 RG66001006 - Rev.04 1000 2000 3000 Qw (l/h) 4000 5000 20 È severamente vietata la riproduzione anche parziale di questo manuale 6000 7000 MCW - MCR 17 CIRCUITO IDRAULICO LATO UTENTE Nel realizzare il circuito idraulico per l’unità, è buona norma attenersi alle seguenti prescrizioni e comunque attenersi alla normativa nazionale o locale. Raccordare le tubazioni al refrigeratore tramite giunti flessibili al fine di evitare la trasmissione delle vibrazioni e compensare le dilatazioni termiche. Si consiglia d’installare sulle tubazioni i seguenti componenti: - Indicatori di temperatura e pressione per la normale manutenzione e controllo del gruppo. Il controllo della pressione lato acqua consente di valutare la corretta funzionalità del vaso d’espansione e d’evidenziare in anticipo eventuali perdite d’acqua dell’impianto. - Pozzetti sulle tubazioni d’ingresso ed uscita per i rilievi di temperatura, per una visione diretta delle temperature d’esercizio. - Valvole di intercettazione (saracinesche) per isolare l’unità dal circuito idraulico. - Filtro metallico (tubazione in ingresso) a rete con maglia non superiore ad 1 mm, per proteggere gli scambiatori (utilizzo e dissipatore) da scorie o impurità presenti nelle tubazioni. - Valvole di sfiato, da collocare nelle parti più elevate del circuito idraulico, per permettere lo spurgo dell’aria. (Sui tubi interni macchina sono presenti delle valvoline di sfiato per lo spurgo di bordo macchina: tale operazione va eseguita con il gruppo privo di tensione). - Rubinetto di scarico e ove necessario, serbatoio di drenaggio per permettere lo svuotamento dell’impianto per le operazioni di manutenzione o le pause stagionali. (Sul serbatoio d’accumulo optional è previsto un rubinetto di scarico da 1”: tale operazione va eseguita con il gruppo privo di tensione). E’ di fondamentale che l’ingresso dell’acqua avvenga in corrispondenza della connessione contrassegnata con la scritta “Ingresso Acqua” In caso contrario si correrebbe il rischio di gelare l’evaporatore, dal momento che il controllo da parte del termostato antigelo verrebbe vanificato ed inoltre non sarebbe rispettata la circuitazione in controcorrente nel funzionamento in raffreddamento con ulteriori rischi di malfunzionamento Il circuito idraulico deve essere realizzato in maniera tale da garantire la costanza della portata d’acqua nominale (+/- 15%) all’evaporatore in ogni condizione di funzionamento. Sulle unità MCW-MCR è previsto di serie un dispositivo per il controllo della portata dell’acqua (pressostato differenziale) sul circuito idraulico ,nelle immediate vicinanze dell’evaporatore. In caso di manomissione di tale dispositivo, la garanzia viene a decadere immediatamente. E’ vivamente consigliata l’installazione di una valvola di sicurezza sul circuito idraulico. In caso di anomalie gravi nell’impianto (ad es. incendio) essa permetterà di scaricare il sistema evitando possibili scoppi. Collegare sempre lo scarico ad una tubazione di diametro non inferiore a quello dell’apertura della valvola, e convogliarlo in zone nelle quali il getto non possa recare danno alle persone. Lo schema idraulico rappresenta un circuito idraulico tipo a cui è collegata un'unità a MCW-MCR completa di gruppo di pompaggio e serbatoio di accumulo esterni. VI VSM AV F Tw DP FL HV GR VE VA SFA SA VI P VI AV Tw SIA RS RS Legenda: Legenda: p Descrizione Pressostato differenziale lato acqua P Descrizione Pompa di circolazione HV Evaporatore AV Antivibrante FL Flussostato F VSM Filtro metallico Valvola di sicurezza a molla VE Vaso di espansione a membrana VA Sfiato aria manuale GR Gruppo di riempimento SIA Serbatoio inerziale di accumulo SA Separatore aria RS Rubinetto di svuotamento TW Pozzetto rilevazione temperatura acqua VI Valvola di intercettazione 21 È severamente vietata la riproduzione anche parziale di questo manuale RG66001006 - Rev.04 MCW - MCR 18 DIMENSIONI DI INGOMBRO MCW 1 2 3 4 5 6 7 8 9 10 Ingresso acqua condensatore (1 1/4" gas) Uscita acqua condensatore (1 1/4" gas) Ingresso acqua evaporatore (1 1/4" gas) Uscita acqua evaporatore (1 1/4" gas) Ingresso alimentazione elettrica Serbatoio di accumulo Manometri refrigerante (opzionali) Controllo a microprocessore Quadro elettrico pompa di ricicolo Dimensioni in mm RG66001006 - Rev.04 VISTA DALL'ALTO VISTA LATO DESTRO VISTA DALL'ALTO VISTA FRONTALE VISTA POSTERIORE VISTA FRONTALE VISTA LATO SINISTRO MCW 005 - 010 22 È severamente vietata la riproduzione anche parziale di questo manuale MCW - MCR 18 DIMENSIONI DI INGOMBRO MCW 1 2 4 4 5 6 7 8 9 10 Ingresso acqua condensatore (1 1/4 " gas) Uscita acqua condensatore (1 1/4 " gas) Ingresso acqua evaporatore (1 1/4" gas) Uscita acqua evaporatore (1 1/4" gas) Ingresso alimentazione elettrica Serbatoio di accumulo Manometri refrigerante (opzionali) Controllo a microprocessore Quadro elettrico pompa di ricicolo Dimensioni in mm VISTA DALL'ALTO VISTA LATO DESTRO VISTA FRONTALE VISTA DALL'ALTO VISTA POSTERIORE VISTA FRONTALE VISTA LATO SINISTRO MCW 012 - 039 23 È severamente vietata la riproduzione anche parziale di questo manuale RG66001006 - Rev.04 MCW - MCR 19 DIMENSIONI DI INGOMBRO MCR MCR 005 - 010 RG66001006 - Rev.04 24 È severamente vietata la riproduzione anche parziale di questo manuale Dimensioni in mm MCW - MCR 19 DIMENSIONI DI INGOMBRO MCR MCR 012 - 039 25 È severamente vietata la riproduzione anche parziale di questo manuale Dimensioni in mm RG66001006 - Rev.04 MCW - MCR 20 DRY COOLER 21 CONDENSATORE REMOTO In abbinamento ai refrigeratori d’acqua condensati ad acqua ed alle motoevaporanti è possibile abbinare DRY COOLER prodotti da LUVE CONTARDO. Nella tabella a fondo pagina sono riportati gli abbinamenti fra modelli di unità galletti ed unità LUVE già selezionate per un ottimale funzionamento alle condizioni nominali; per condizioni diverse dalle nominali, verificare l’abbinamento con la sede. Le versioni proposte sono: - DRY COOLER in esecuzione standard, mandata aria orizzontale, completo di interruttore ON/OFF e cablaggi. - DRY COOLER in esecuzione standard completo di controllo di velocità, mandata aria orizzontale, interruttore ON/OFF, sonda temperatura e cablaggi. - DRY COOLER in esecuzione standard, mandata aria verticale, completo di kit gambe, interruttore ON/OFF e cablaggi. - DRY COOLER in esecuzione standard completo di controllo di velocità, mandata aria verticale, kit gambe, interruttore ON/OFF, sonda aria e cablaggi. - DRY COOLER in esecuzione silenziata, mandata aria orizzontale,completo, di interruttore ON/OFF e cablaggi. - DRY COOLER in esecuzione silenziata completo di controllo di velocità, mandata aria orizzontale, interruttore ON/OFF, sonda temperatura e cablaggi. - DRY COOLER in esecuzione silenziata, mandata aria verticale, completo di kit gambe, interruttore ON/OFF e cablaggi. - DRY COOLER in esecuzione silenziata completo di controllo di velocità, mandata aria verticale, kit gambe, interruttore ON/OFF, sonda temperatura e cablaggi. In abbinamento ai refrigeratori d’acqua condensati ad acqua ed alle motoevaporanti è possibile abbinare CONDENSATORI REMOTI prodotti da LUVE CONTARDO. Nella tabella a fondo pagina sono riportati gli abbinamenti fra modelli di unità galletti ed unità LUVE già selezionate per un ottimale funzionamento alle condizioni nominali; per condizioni diverse dalle nominali, verificare l’abbinamento con la sede. Le versioni proposte sono: - CONDENSATORE REMOTO in esecuzione standard, mandata aria orizzontale, completo di interruttore ON/OFF e cablaggi. - CONDENSATORE REMOTO in esecuzione standard completo di controllo di velocità, mandata aria orizzontale, interruttore ON/OFF, sonda pressione e cablaggi. - CONDENSATORE REMOTO in esecuzione standard, mandata aria verticale,completo di kit gambe, interruttore ON/OFF e cablaggi. - CONDENSATORE REMOTO in esecuzione standard completo di controllo di velocità, mandata aria verticale, kit gambe, interruttore ON/OFF, sonda pressione e cablaggi. - CONDENSATORE REMOTO in esecuzione silenziata, mandata aria orizzontale, completo di interruttore ON/OFF e cablaggi. - CONDENSATORE REMOTO in esecuzione silenziata completi di controllo di velocità, mandata aria orizzontale, completo di interruttore ON/OFF, sonda pressione e cablaggi. - CONDENSATORE REMOTO in esecuzione silenziata, mandata aria verticale,completi di kit gambe, interruttore ON/OFF e cablaggi. - CONDENSATORE REMOTO in esecuzione silenziata completo di controllo di velocità, mandata aria verticale, kit gambe, interruttore ON/OFF, sonda pressione e cablaggi. 20.1 TABELLA ABBINAMENTO DRY COOLER 21.1 TABELLA ABBINAMENTO CONDENSATORE REMOTO MODELLO MCW CL MCW HL 005 007 010 012 015 018 020 022 027 031 039 RG66001006 - Rev.04 Codice Codice MCR Condensatore remotoCondensatore remoto Alimentazione MODELLO flusso aria flusso aria elettrica CS verticale orizzontale V - ph - Hz 005 SHVN 7/7 H SHVN 7/7 V 230-1-50 hz 007 SHVN 7/7 H SHVN 7/7 V 230-1-50 hz 010 SHVN 13/9 H SHVN 13/9 V 230-1-50 hz 012 SHVN 13/9 H SHVN 13/9 V 230-1-50 hz 015 SHVN 20/4 H SHVN 20/4 V 230-1-50 hz 018 SHVN 20/4 H SHVN 20/4 V 230-1-50 hz 020 SHVN 23/2 H SHVN 23/2 V 230-1-50 hz 022 SHVN 23/2 H SHVN 23/2 V 230-1-50 hz 027 SHVN 38/1 H SHVN 38/1 V 230-1-50 hz 031 SHVN 38/1 H SHVN 38/1 V 230-1-50 hz 039 SHVN 46/5 H SHVN 46/5 V 230-1-50 hz Codice Codice MCR Condensatore remotoCondensatore remoto Alimentazione MODELLO CL flusso aria flusso aria elettrica verticale orizzontale V - ph - Hz 005 SHVS 8/2 H SHVS 8/2 V 230-1-50 hz 007 SHVS 8/2 H SHVS 8/2 V 230-1-50 hz 010 SHVS 18/0 H SHVS 18/0 V 230-1-50 hz 012 SHVS 18/0 H SHVS 18/0 V 230-1-50 hz 015 SHVS 18/0 H SHVS 18/0 V 230-1-50 hz 018 SHVS 18/0 H SHVS 18/0 V 230-1-50 hz 020 SHVS 27/1 H SHVS 27/1 V 230-1-50 hz 022 SHVS 27/1 H SHVS 27/1 V 230-1-50 hz 027 SHVS 36/0 H SHVS 36/0 V 230-1-50 hz 031 SHVS 36/0 H SHVS 36/0 V 230-1-50 hz 039 SHVS 48/1 H SHVS 48/1 V 230-1-50 hz Alimentazione elettrica V - ph - Hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz Alimentazione elettrica V - ph - Hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz 230-1-50 hz / 400-3-50 hz MONOCIRCUITO 005 007 010 012 015 018 020 022 027 031 039 Codice dry-cooler Codice dry-cooler flusso aria flusso aria verticale orizzontale SHLR 15 M H SHLR 15 M V SHLR 15 M H SHLR 15 M V SHLN 24 D H SHLN 24 D V SHLN 24 D H SHLN 24 D V SHLN 24 D H SHLN 24 D V SHLN 29 L H SHLN 29 L V SHLN 30 D H SHLN 30 D V SHLN 30 D H SHLN 30 D V SHLN 50 C H SHLN 50 C V SHLN 50 C H SHLN 50 C V SHLN 58 D H SHLN 58 D V Codice dry-cooler Codice dry-cooler flusso aria flusso aria verticale orizzontale SHLR 15 M H SHLR 15 M V SHLR 15 M H SHLR 15 M V SHLS 19 M H SHLS 19 M V SHLS 19 M H SHLS 19 M V SHLS 38 D H SHLS 38 D V SHLS 38 D H SHLS 38 D V SHLS 38 D H SHLS 38 D V SHLS 38 D H SHLS 38 D V SHLS 38 D H SHLS 38 D V SHLS 59 C H SHLS 59 C V SHLS 59 C H SHLS 59 C V MONOCIRCUITO MONOCIRCUITO MCW CS MCW HS MONOCIRCUITO MODELLO 26 È severamente vietata la riproduzione anche parziale di questo manuale MCW - MCR 21 CONDENSATORE REMOTO 21.2 DIMENSIONAMENTO DELLE LINEE FRIGORIFERE PARAMETRI GENERALI Il circuito frigorifero deve essere dimensionato seguendo 3 indicazioni fondamentali: - 1. 2. 3. Refrigerante Potenza frigorifera T ev. - Dew Point Linea gas 0-10m Linea liquido 0-10m Linea gas 11-20m Linea liquido 11-20m Linea gas 21-30m Linea liquido 21-30m 21 - Mantenere il più possibile contenute le perdite di carico del refrigerante per evitare significativi cali di prestazioni. Assicurarsi di avere la corretta quantità di olio sul ritorno anche nel funzionamento ai carichi parziali quando la velocità del refrigerante è ridotta. La perdita di carico depende dall'entità dell'attrito tra la rugosità interna del tubo e il gas refrigerante e tale rugosità è anche responsabile del trascinamento dell'olio. Il trascinamento dell'olio è più critico sulla linea di aspirazione a causa delle basse tempearture che ne aumentano la viscosità. Evitare la formazione di "vapori di flash" sulla linea del liquido con conseguente malfunzionamento della valvola di laminazione: mantenere una velocità del liquido bassa per evitare picchi di pressione durante la chiusura della valvola di espansione. minima velocità del gas refrigerante per assicurare il trascinamento dell'olio anche in tubazioni verticali, sulla linea del gas 4 m/s; sulla linea del liquido, la miscibilità tra olio e refrigerante è totale (nel campo dei limiti di funzionamento) e non occorre perciò rispettare nessuna velocità minima. R407C R407C R407C R407C R407C R407C R407C R407C R407C R407C R407C kW 4-5 6-7 8-9 10-11,5 11,5-13 14-16 17-18 19-24 25-29 30-34 35-40 °C 0/+10°C 0/+10°C 0/+10°C 0/+10°C 0/+10°C 0/+10°C 0/+10°C 0/+10°C 0/+10°C 0/+10°C 0/+10°C [mm] 12 12 12 16 16 16 16 22 22 22 28 [mm] 10 10 10 12 12 12 12 16 16 16 18 [mm] 12 12 16 16 16 18 18 22 22 28 28 [mm] 10 10 12 12 12 12 12 16 16 18 18 [mm] 12 12 16 16 16 18 18 22 22 28 28 [mm] 10 10 12 12 12 12 12 16 16 18 18 CONDENSATORE REMOTO 21.3 CARATTERISTICHE TUBO REFRIGERANTE Diametro esterno [mm] 10 12 16 18 22 28 35 42 54 Spessore [mm] 1 1 1 1 1,5 1,5 1,5 1,5 2 Raggio di curvatura [mm] 36 36 46 56 67 96 70 84 108 Pressione di progetto [bar] 28 28 28 28 28 28 28 28 28 27 Categoria tubi PED max.carico unitario carico effettivo Coefficiente di sicurezza A3 P3 A3 P3 A3 P3 A3 P3 A3 P3 A3 P3 A3P3 A3P3 A3P3 [N/mm2 ] 227 227 227 227 227 227 227 227 227 [N/mm2 ] 11,2 14 19,6 21 17,3 23,3 29,8 36,4 35 20,3 16,2 11,6 10,8 13,1 9,8 7,6 6,2 6,4 È severamente vietata la riproduzione anche parziale di questo manuale RG66001006 - Rev.04 MCW - MCR 21 CONDENSATORE REMOTO 21.4 ESEMPI DI COLLEGAMENTO 21.4.1 Condensatore remoto a monte della motoevaporante RG66001006 - Rev.04 28 È severamente vietata la riproduzione anche parziale di questo manuale MCW - MCR 21 CONDENSATORE REMOTO 21.4 ESEMPI DI COLLEGAMENTO 21.4.2 Condensatore remoto a valle della motoevaporante 29 È severamente vietata la riproduzione anche parziale di questo manuale RG66001006 - Rev.04 MCW - MCR 22 POSIZIONAMENTO E SPAZI DI INSTALLAZIONE E’ opportuno prestare attenzione ai punti seguenti per determinare il sito migliore ove installare l’unità ed i relativi collegamenti: dimensioni e provenienza delle tubazioni idrauliche; ubicazione dell’alimentazione elettrica; accessibilità per le operazioni di manutenzione o riparazione; solidità del piano di supporto; possibile riverbero delle onde sonore. Tutti i modelli della serie MCW-MCR sono progettati e costruiti per installazioni all'interno. E’ consigliabile interporre tra il telaio di base ed il piano di appoggio un nastro di gomma rigido. Qualora si necessitasse di un isolamento più spinto è opportuno l’impiego di supporti antivibranti a molla. È necessario garantire gli spazi di servizio indicati nelle figure riportate di seguito. RG66001006 - Rev.04 30 È severamente vietata la riproduzione anche parziale di questo manuale NOTE www.galletti.it 40010 Bentivoglio (BO) Via Romagnoli 12/a Tel. 051/8908111 - Fax. 051/8908122 Azienda certificata UNI EN ISO 9001 e OHSAS 18001