Download AXP640 Safety Notes Summary - Artesyn Embedded Technologies

Transcript
AXP640
Safety Notes Summary
P/N: 6806800T70A
August 2015
©
Copyright 2015 Artesyn Embedded Technologies, Inc.
All rights reserved.
Trademarks
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of
Artesyn Embedded Technologies, Inc.© 2015 Artesyn Embedded Technologies, Inc. All other product or service names are the
property of their respective owners.
Intel® is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
Java™ and all other Java-based marks are trademarks or registered trademarks of Oracle America, Inc. in the U.S. and other countries.
Microsoft®, Windows® and Windows Me® are registered trademarks of Microsoft Corporation; and Windows XP™ is a trademark of
Microsoft Corporation.
PICMG®, CompactPCI®, AdvancedTCA™ and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI
Industrial Computer Manufacturers Group.
UNIX® is a registered trademark of The Open Group in the United States and other countries.
Notice
While reasonable efforts have been made to assure the accuracy of this document, Artesyn assumes no liability resulting from any
omissions in this document, or from the use of the information obtained therein. Artesyn reserves the right to revise this document
and to make changes from time to time in the content hereof without obligation of Artesyn to notify any person of such revision or
changes.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to
an Artesyn website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise
altered without the permission of Artesyn.
It is possible that this publication may contain reference to or information about Artesyn products (machines and programs),
programming, or services that are not available in your country. Such references or information must not be construed to mean that
Artesyn intends to announce such Artesyn products, programming, or services in your country.
Limited and Restricted Rights Legend
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply
unless otherwise agreed to in writing by Artesyn.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in
Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and
Documentation clause at DFARS 252.227-7014 (Jun. 1995).
Contact Address
Artesyn Embedded Technologies
Artesyn Embedded Technologies
Marketing Communications
Lilienthalstr. 17-19
2900 S. Diablo Way, Suite 190
85579 Neubiberg/Munich
Tempe, Arizona 85282
Germany
About this Manual
Summary of Changes
This manual has been revised and replaces all prior editions.
Part Number
Publication Date
Description
6806800T70A
August 2015
Initial version
AXP640 Safety Notes Summary (6806800T70A)
3
About this Manual
4
About this Manual
AXP640 Safety Notes Summary (6806800T70A)
Safety Notes
This section provides warnings that precede potentially dangerous procedures throughout
this manual. Instructions contained in the warnings must be followed during all phases of
operation, service, and repair of this equipment. You should also employ all other safety
precautions necessary for the operation of the equipment in your operating environment.
Failure to comply with these precautions or with specific warnings elsewhere in this manual
could result in personal injury or damage to the equipment.
Artesyn intends to provide all necessary information to install and handle the product in this
manual. Because of the complexity of this product and its various uses, we do not guarantee
that the given information is complete. If you need additional information, ask your Artesyn
representative.
The product has been designed to meet the standard industrial safety requirements. It must
only be used in its specific area of office telecommunication industry, industrial control, and
development. It must not be used in safety critical components, life supporting devices or on
aircraft.
Only personnel trained by Artesyn or persons qualified in electronics or electrical engineering
are authorized to install, remove or maintain the product. The information given in this manual
is meant to complete the knowledge of a specialist and must not be used as replacement for
qualified personnel.
Keep away from live circuits inside the equipment. Operating personnel must not remove
equipment covers. Only factory authorized service personnel or other qualified service
personnel may remove equipment covers for internal subassembly or component replacement
or any internal adjustment.
Do not install substitute parts or perform any unauthorized modification of the equipment or
the warranty may be voided. Contact your local Artesyn representative for service and repair
to make sure that all safety features are maintained.
General
Danger of Injuries
At the system's rear there are sharp pins which can cause injuries.
Be careful when handling the system.
AXP640 Safety Notes Summary (6806800T70A)
5
Safety Notes
EMC
The product has been tested and found to comply with the limits for a Class A digital device in
this system, pursuant to part 15 of the FCC Rules, EN 55022 Class A respectively. These limits
are designed to provide reasonable protection against harmful interference when the product
is operated in a commercial, business or industrial environment.
The product generates and uses radio frequency energy and, if not installed properly and used
in accordance with this user's documentation, may cause harmful interference to radio
communications. Operating the product in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his own
expense.
To ensure EMC protection use only shielded cables when connecting peripherals to assure that
appropriate radio frequency emissions compliance is maintained. Installed blades must have
the face plates installed and all vacant slots in the shelf must be covered.
An AXP640 that is shipped as a spare, replacement chassis, or an unconfigured system will not
have filler panels installed. It is the responsibility of the customer to ensure that all open slots
are filled with payload blades, rear transition modules (RTMs), or approved filler panels in order
to be compliant with the safety/EMC regulatory markings.
Grounding
To ensure the system is properly grounded, each of the system's parts must contact the EMI
gasket. The system contains gaskets at the shelf and module level.
The shelf is also fitted with ESD contacts. Please take care for proper ESD protection of the
operator.
This is a Class A product based on the standard of the Voluntary Control Council for
Interference by Information Technology Interference (VCCI). If this equipment is used in a
domestic environment, radio disturbance may arise. When such trouble occurs, the user may
be required to take corrective actions.
The equipment is suitable for installation in a Common Bonding Network (CBN) or Isolated
Bonding Network (IBN).
6
AXP640 Safety Notes Summary (6806800T70A)
Safety Notes
System Installation
System Damage
To avoid system damage verify that the system environment meets the environmental and
power requirements given in this manual before installing the system.
Before you begin to set up and cable your new system, consider these guidelines:

Restricted access area: Install the system only in a restricted access area.

Installation codes: This unit must be installed in accordance with the National Electrical
Code, Articles 110.16, 110.17, and 110.18 and the Canadian Electrical Code, Section 12.a

Overcurrent protection: A readily accessible listed branch circuit overcurrent protective
device must be incorporated into the building wiring. For appropriate AWG rating of the
overcurrent protection device see NEC Table 310.16 and other national regulations.

The protective bonding conductor depends on your power distribution topology. Make
sure that you use an appropriate protective bonding conductor regarding the rating of the
branch circuit protection.

Install the system safely. Make sure that cables and cords are out of the way.

Make sure that the set-up is comfortable for users.
System Damage
WARNING: The intra-building port(s) of the equipment or subassembly is suitable for
connection to intra-building or unexposed wiring or cabling only. The intra-building port(s) of
the equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the OSP or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require isolation from the
exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to
connect these interfaces metallically to OSP wiring.
System Damage
Environmental contamination can impair system operation.
Locate the system in a stable area free of excess movement and jarring and free of dust, smoke,
and electrostatic discharge (ESD). Make sure that the temperature does not exceed the
operating temperature given in the environmental requirements in this manual and allow
room for proper air flow for cooling.
AXP640 Safety Notes Summary (6806800T70A)
7
Safety Notes
Personal Injury or System Damage
The system is supplied by a TNV2 voltage. This voltage is considered hazardous.
Make sure that the power supply meets the local safety standards.
System Overheating
Inproper cooling leads to blade damage.
To ensure proper cooling always operate the system in a horizontal position. Furthermore,
keep clear at least 6 cm adjacent to the cooling vents on the chassis front and back side.
Personal or System Damage
Unstable system installation in a rack can cause the rack to topple over.
Therefore, if your system is the only one in the rack, make sure to mount the system in the
lowest part of the rack. If other systems are installed in one rack, start with the heaviest
component at the bottom.
If the rack is equipped with stabilizing devices, make sure that they are installed and extended
so that the rack is secure. Then proceed to mount or service the system.
Personal Injury or System Damage
When pulling the system out of the rack, it can fall down and cause injuries.
Pull out the system cautiously.
Personal Injury or System Damage
The system is heavy and if you carry it on your own you can hurt your back.
To prevent injury, keep your back straight and have two people lift the system or use additional
lifting equipment.
System Damage
During the course of handling, shipping, and assembly, pins, shrouds and mounting screws,
fans and other items can become loose or damaged.
Do not operate a damaged shelf, this can cause damage to devices that interface with it.
8
AXP640 Safety Notes Summary (6806800T70A)
Safety Notes
Electrical Hazard
The caution label on the system's rear near the grounding studs shows that you have to create
an earth connection because there may be a high leakage current which is considered as
hazardous.
High leakage current can cause injuries. Therefore, it is essential that you create an earth
connection before connecting the PEM to a telecommuncation network.
System Damage
Wrong jumper settings can make the shelf in-operable. Therefore, never change the settings
of the jumpers.
Blade and RTM Installation
Damage of Circuits
Electrostatic discharge and incorrect RTM or blade installation and removal can damage
circuits or shorten their life.
Before touching the RTM, blade or electronic components, make sure that you are working in
an ESD-safe environment.
Installation Sequence of RTMs and AdvancedTCA Blades
If you are going to install an RTM and an AdvancedTCA blade you have to regard the following
sequence:
First install the RTM, then install the matching AdvancedTCA blade. Otherwise the blades and
RTMs will be damaged.
Blade or System Damage
Installing a blade in the wrong slot causes blade or system damage.
Only install blades in the designated slots.
AXP640 Safety Notes Summary (6806800T70A)
9
Safety Notes
Damage of RTM and Front Blade
Removing the RTM from the system while the playload of the front blade is powered up may
damage the front blade and RTM.
Whenever removing the RTM from the system, you have to power down the playload of the
front blade first.
RTM Malfunctioning
Incorrect RTM installation and removal can result in RTM malfunctioning.
When plugging the RTM in or removing it, do not press on the face plate but use the handles.
RTM Damage
Installing the RTM with other blades than the ones designed for it may damage the RTM and
the front blade.
Only install the RTM with the correct front blade.
Data Loss
Removing the RTM with the system power on and the blue LED on the front blade still flashing
causes data loss.
Before removing the RTM from a powered system, power down the slot by opening the lower
handle of the front blade and wait until the blue LED is permanently ON.
Blade Malfunctioning
Incorrect blade installation and removal can result in blade malfunctioning.
Make sure that the blade is connected to the system backplane through all assembled
connectors and that power is available on all zone 1 power pins.
Operation
System Overheating
Cooling vents
Inproper cooling can lead to blade and system damage.
10
AXP640 Safety Notes Summary (6806800T70A)
Safety Notes
To ensure proper cooling and undisturbed airflow through the system always operate the
system in a horizontal position and keep clear at least 60 mm at the back of the system. Do not
obstruct the ventilation openings at the top and back of the system. Keep the fresh air intake
at the bottom front side of the chassis completely clear, and ensure that fresh air supply is not
mixed with hot exhaust from other devices.
To ensure proper air flow within the system make sure that all slots are populated with either
filler blades, blades or dummy blades.
Product Damage
High humidity and condensation on blade surfaces causes short circuits.
Do not operate the system outside the specified environmental limits. Make sure the system is
completely dry and there is no moisture on any surface before applying power. Do not start the
system below 0ºC.
Injury
Caution: this unit has four -48V to -60V DC feeds. All must be disconnected to de-energize the
system. To reduce the risk of injury, disconnect the feeds when removing power from the
system.
System Damage
Air Filter
Air contamination can pollute the air filter and obstruct the air intake of the system which may
cause system overheating and component damage.
To guarantee proper airflow through the system, the air filter has to be replaced at least every
six months. Artesyn Embedded Technologies recommends to replace the air filter every 90
days. Filter replacement frequency depends on the environment the system is subjected to.
Because central offices vary in physical location and cleanliness, check your air filters every
week after you first install your system. In a dusty environment, a filter may need cleaning
more often than a filter in a cleaner environment. Check the filters frequently until you have a
good idea of how often it needs cleaning. Based on your findings, establish a regular cleaning
schedule and keep a log to record the date of each filter cleaning or replacement.
AXP640 Safety Notes Summary (6806800T70A)
11
Safety Notes
This equipment is designed to permit the connection of the earthed conductor of the DC
supply circuit to the earthing conductor at the equipment. If this connection is made, all of the
following conditions must be met:

This equipment shall be connected directly to the DC supply system earthing electrode
conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC
supply system earthing electrode conductor is connected.

This equipment shall be located in the same immediate area (such as, adjacent cabinets)
as any other equipment that has a connection between the earthed conductor of the same
DC supply circuit and the earthing conductor, and also the point of earthing of the DC
system. The DC system shall not be earthed elsewhere.

The DC supply source shall be located within the same premises as this equipment.

Switching or disconnecting devices shall not be in the earthed circuit conductor between
the DC source and the point of connection of the earthing electrode conductor.
French translation: Cet appareil est conçu pour permettre le raccordement du conducteur relié
à la terre du circuit d'alimentation c.c. au conducteur de terre de l'appareil. Pour ce
raccordement, toutes les conditions suivantes doivent être respectées:

Ce matériel doit être raccordé directement au conducteur de la prise de terre du circuit
d'alimentation c.c. ou à une tresse de mise à la masse reliée à une barre omnibus de terre
laquelle est raccordée à l'électrode de terre du circuit d'alimentation c.c.

Les appareils dont les conducteurs de terre respectifs sont raccordés au conducteur de
terre du même circuit d'alimentation c.c. doivent être installés à proximité les uns des
autres (p.ex., dans des armoires adjacentes) et à proximité de la prise de terre du circuit
d'alimentation c.c. Le circuit d'alimentation c.c. ne doit comporter aucune autre prise de
terre.

La source d'alimentation du circuit c.c. doit être située dans la même pièce que le matériel.
- Il ne doit y avoir aucun dispositif de commutation ou de sectionnement entre le point de
raccordement au conducteur de la source d'alimentation c.c. et le point de raccordement
à la prise de terre.
System Overheating
If you reduce the fan speed, the system temperature will rise.
Constantly control the system temperature once you have reduced the fan speed.
While operating the system ensure that the environmental and power requirements are met.
12
AXP640 Safety Notes Summary (6806800T70A)
Safety Notes
Injuries or Short Circuits
Blade or Power Supply
In case the ORing diodes of the blade fail, the blade may trigger a short circuit between input
line A and input line B so that line A remains powered even if it is disconnected from the power
supply circuit (and vice versa).
To avoid damage or injuries, always check that there is no more voltage on the line that has
been disconnected before continuing your work.
Expansion
System Overload
To avoid an overload of the system check the total power consumption of all components
installed (see the technical specification of the respective components). Ensure that any
individual output current of any source stays within its acceptable limits (see the technical
specification of the respective source).
Loss of Safety Compliance
Using of Additional Plug-in Blades
By using additional plug-in blades it may be possible that the system may be no more
compliant to safety and EMC regulations.
The system integrator has to ensure that the compliancy is guaranteed.
Exchanging PEMs
Personal Injury through Electric Shock and Burning
Touching the PEM power input terminals with metallic objects on your hands, wrists, or
hanging from your neck may lead to serious injuries like burns or amputations. Do not wear any
metallic attire or commodity on your hands, wrists, or hanging from your neck when working
at the power input terminals or power input cables. Be extremely careful when you use
electrically conductive tools near the PEMs.
Short Circuits or Personal Injury
Ensure that the power feeds you plan to remove or attach are powered off and cannot be
switched on while you are working.
AXP640 Safety Notes Summary (6806800T70A)
13
Safety Notes
Short Circuit and Electric Shock
To avoid short circuits and electric shock, the power lugs must not be energized before
removing the screws. It is essential to ensure that the power lugs are not energized before
loosening the screws. Be careful with the used tools in order to prevent a short circuit.
PEM Damage
Applying reversal power causes damage to the electrolytic capacitors of the filter. Therefore,
only switch on the breakers if no red light is visible.
Exchanging Fans
Personal Injury
Rotating Fans
Inserting tools or fingers into operational fans may cause injuries.
Fans become exposed when the fan tray is pulled. Keep clear of the fans as long as they are
rotating.
When the fan is removed, extreme care should be taken while handling the fan itself. The
centrifugal forces will make the unit difficult to handle.
Cabling
Personal Injury
The cabling should follow existing cable paths using existing or similar cable fastenings.
Never change the system's cabling as delivered by Artesyn. Check proper function of the
system after cabling extensions. To avoid injuries always ensure that cables are securely
installed so that nobody can trip over them.
Personal Injury through Electric Shock
Touching contacts and cables during system operation can cause injuries through electric
shock.
To avoid electric shock make sure that contacts and cables of the system cannot be touched
while the system is operating. If in doubt concerning cabling, ask your local Artesyn
representative.
14
AXP640 Safety Notes Summary (6806800T70A)
Safety Notes
Cable Damage
Folding the fiber cable damages the cable and inhibits the data transmission. Therefore, make
sure you do not fold the cable.
RJ-45 Connector
System Damage
RJ-45 connectors on blades are either twisted-pair Ethernet (TPE) or E1/T1/J1 network
interfaces. Connecting an E1/T1/J1 line to an Ethernet connector may damage your system.

Make sure that TPE connectors near your working area are clearly marked as network
connectors.

Verify that the length of an electric cable connected to a TPE bushing does not exceed 100
m.

Make sure the TPE bushing of the system is connected only to safety extra low voltage
circuits (SELV circuits).

If in doubt, ask your system administrator.
Laser
Personal Injury
If a label with the words CLASS 1 LASER PRODUCT is affixed to the back of your system, the unit
is equipped with a laser device. These devices contain a laser diode that produces invisible laser
radiation harmful to the eyes.
Performing adjustments or procedures other than those specified in this manual may result in
hazardous radiation exposure. Do not look into the optical lens at any time.
Battery
Blade Damage
Wrong battery installation may result in hazardous explosion and blade damage.
AXP640 Safety Notes Summary (6806800T70A)
15
Safety Notes
Always use the same type of battery as is installed and make sure the battery is installed as
described in the user manual of the blade.
Always dispose of old batteries according to your country's legislation.
Environment
Environmental
Always dispose of used blades, system components and RTMs according to your country’s
legislation and manufacturer’s instructions.
16
AXP640 Safety Notes Summary (6806800T70A)
Sicherheitshinweise
Dieses Kapitel enthält Hinweise, die potentiell gefährlichen Prozeduren innerhalb dieses
Handbuchs vorrangestellt sind. Beachten Sie unbedingt in allen Phasen des Betriebs, der
Wartung und der Reparatur des Systems die Anweisungen, die diesen Hinweisen enthalten
sind. Sie sollten außerdem alle anderen Vorsichtsmaßnahmen treffen, die für den Betrieb des
Systems innerhalb Ihrer Betriebsumgebung notwendig sind. Wenn Sie diese
Vorsichtsmaßnahmen oder Sicherheitshinweise, die an anderer Stelle diese Handbuchs
enthalten sind, nicht beachten, kann das Verletzungen oder Schäden am System zur Folge
haben.
Artesyn Embedded Technologies ist darauf bedacht, alle notwendigen Informationen zum
Einbau und zum Umgang mit dem System in diesem Handbuch bereit zu stellen. Da es sich
jedoch bei dem System um ein komplexes Produkt mit vielfältigen Einsatzmöglichkeiten
handelt, können wir die Vollständigkeit der im Handbuch enthaltenen Informationen nicht
garantieren. Falls Sie weitere Informationen benötigen sollten, wenden Sie sich bitte an die für
Sie zuständige Geschäftsstelle von Artesyn.
Das System erfüllt die für die Industrie geforderten Sicherheitsvorschriften und darf
ausschließlich für Anwendungen in der Telekommunikationsindustrie, im Zusammenhang mit
Industriesteuerungen und in der Entwicklung verwendet werden. Es darf nicht in
sicherheitskritischen Anwendungen, lebenserhaltenden Geräten oder in Flugzeugen
verwendet werden.
Einbau, Wartung und Betrieb dürfen nur von durch Artesyn Embedded Technologies
ausgebildetem oder im Bereich Elektronik oder Elektrotechnik qualifiziertem Personal
durchgeführt werden. Die in diesem Handbuch enthaltenen Informationen dienen
ausschließlich dazu, das Wissen von Fachpersonal zu ergänzen, können dieses jedoch nicht
ersetzen.
Halten Sie sich von stromführenden Leitungen innerhalb des Systems fern. Entfernen Sie auf
keinen Fall die Systemabdeckung. Nur werksseitig zugelassenes Wartungspersonal oder
anderweitig qualifiziertes Wartungspersonal darf die Systemabdeckung entfernen, um
Systemkomponenten zu ersetzen oder andere Anpassungen vorzunehmen.
Installieren Sie keine Ersatzteile oder führen Sie keine unerlaubten Veränderungen am System
durch, sonst verfällt die Garantie. Wenden Sie sich für Wartung oder Reparatur bitte an die für
Sie zuständige Geschäftsstelle von Artesyn. So stellen Sie sicher, dass alle
sicherheitsrelevanten Aspekte beachtet werden.
AXP640 Safety Notes Summary (6806800T70A)
17
Sicherheitshinweise
Allgemein
Verletzungsgefahr
An der Rückseite des Systems befinden sich spitze Stifte, an denen Sie sich verletzen können.
Seien Sie vorsichtig im Umgang mit dem System.
EMV
Das Produkt wurde getestet und erfüllt die für digitale Geräte der Klasse A gültigen Grenzwerte
gemäß den FCC-Richtlinien Abschnitt 15 bzw. EN 55022 Klasse A. Diese Grenzwerte sollen
einen angemessenen Schutz vor Störstrahlung beim Betrieb des Produkts in Geschäfts-,
Gewerbe- sowie Industriebereichen gewährleisten.
Das Produkt arbeitet im Hochfrequenzbereich und erzeugt Störstrahlung. Bei
unsachgemäßem Einbau und anderem als in diesem Handbuch beschriebenen Betrieb können
Störungen im Hochfrequenzbereich auftreten.
Benutzen Sie zum Anschließen von Peripheriegeräten ausschließlich abgeschirmte Kabel. So
stellen Sie sicher, dass ausreichend Schutz vor Störstrahlung vorhanden ist. Die Blades müssen
mit der Frontblende installiert und alle freien Steckplätze müssen mit Blindblenden abgedeckt
sein.
Ein AXP640, das als Ersatzteil, Austauschchassis oder unkonfiguriertes System ausgeliefert
wird, enthält keine Platzhalter-Boards. Es liegt in der Kundenverantwortung sicherzustellen,
dass alle leeren Steckplätze mit Boards, RTMs oder zugelassenen Platzhalter-Boards belegt
sind, um die Sicherheits- und EMC-Vorschriften zu erfüllen.
Erdung
Um eine korrekte Erdung des Systems zu gewährleisten, befinden sich sowohl am System als
auch an den einzelnen Modulen Dichtungen. Stellen Sie sicher, dass alle Systemteile die EMI
Dichtung berühren.
Am System befinden sich auch ESD Kontakte. Stellen Sie sicher, dass jede Person, die mit dem
System arbeitet, mit ESD-Schutz, zum Beispiel ESD Bändern, ausgerüstet ist.
18
AXP640 Safety Notes Summary (6806800T70A)
Sicherheitshinweise
Das Produkt ist eine Einrichtung der Klasse A gemäß dem Standard des Voluntary Control
Council for Interference von Information Technology Interference (VCCI). Wird das Produkt in
Wohngegenden betrieben, können Störungen im Hochfrequenzbereich auftreten. In einem
solchen Fall ist der Benutzer verpflichtet, entsprechende Gegenmaßnahmen zu ergreifen.
Das Produkt ist für den Einsatz in Netzwerken mit gemeinsamem Potentialausgleich oder mit
isoliertem Potentialausgleich geeignet.
Systeminstallation
Beschädigung des Systems
Bevor Sie das System installieren, überprüfen Sie, ob die im Handbuch beschriebenen
Anforderungen erfüllt werden.
Beachten Sie folgende allgemeinen Sicherheitshinweise vor der Installation und Verkabelung
des Systems:

Bereich mit eingeschränktem Zugang - Installieren Sie das System nur in Bereichen mit
eingeschränktem Zugang.

Installationsrichtlinien: Dieses System muss gemäß folgender Richtlinien installiert
werden: National Electrical Code, Artikel 110.16, 110.17 und 110.18 und Canadian
Electrical Code, Abschnitt 12.a

Überstrom Schutzeinrichtung - Eine leicht zugängliche Trennvorrichtung muss in der
Gebäudeverkabelung eingebaut sein. Einen angemessenen AWG (American Wire Gauge amerikanische Norm für Drahtquerschnitte) Wert der Überstrom Schutzeinrichtung
können Sie der NEC (National Electrical Code) Tabelle 310.16 oder anderen nationalen
Regelwerken entnehmen.

Der Erdungsleiter ist abhängig von der Spannungsverteilungstopologie innerhalb Ihrer
Anlage. Stellen Sie sicher, dass Sie einen angemessenen Erdungsleiter gemäß der
Auslegung des Zugangsleitungsschutzes verwenden.

Bauen Sie das System sicher ein. Stellen Sie sicher, dass Kabel und Leitungen nicht im Weg
sind.

Stellen Sie sicher, dass der Systemaufbau anwenderfreundlich ist.
AXP640 Safety Notes Summary (6806800T70A)
19
Sicherheitshinweise
Beschädigung des Systems
Die Gebäude-internen Schnittstellen ("intra-building ports" per GR-1089-CORE) der Geräte
oder Baugruppen sind nur für gebäudeinterne Verkabelung vorgesehen. Die Schnittstellen
sind als Typ 2 oder Typ 4 definiert (wie in GR-1089-Core beschrieben) und erfordern eine
Isolation zu Leitungen außerhalb des Gebäudes.
Die Gebäude-internen Schnittstellen dürfen keine elektrisch leitende Verbindung zu Leitungen
außerhalb des Gebäudes haben. Ein "Primary Protector" (wie in GR-1089-CORE beschrieben)
ist keine ausreichende Absicherung, um die Gebäude-internen Schnittstellen mit Leitungen
außerhalb des Gebäudes zu verbinden.
Beschädigung des Systems
Verschmutzungen können das System beschädigen.
Betreiben Sie das System an einem erschütterungsfreien Ort, an dem weder Staub, Rauch noch
elektrostatische Entladungen auftreten. Stellen Sie außerdem sicher, dass die klimatischen
Bedingungen, die in diesem Handbuch spezifiziert sind, eingehalten werden und genug Raum
für die Luftzirkulation vorhanden ist.
Verletzungsgefahr und Beschädigung des Systems
Das System ist an eine TNV-2 Spannungsquelle angeschlossen. Diese Spannung kann
gefährlich sein.
Stellen Sie sicher, dass die externe Spannungsversorgung den entsprechenden
Sicherheitsstandards entspricht.
System Überhitzung
Unzureichende Kühlung kann zu einer Beschädigung der Boards führen.
Um eine ausreichende Kühlung sicherzustellen betreiben Sie das System nur aufrecht. Sorgen
Sie außerdem dafür, dass ein aureichender Mindestabstand (mindestens 6 cm) vor den
Lüftungsschlitzen an der Vorder- und Rückseite des Systems freigehalten wird.
20
AXP640 Safety Notes Summary (6806800T70A)
Sicherheitshinweise
Verletzungsgefahr und Beschädigung des Systems
Wenn die Gewichte im Schaltschrank ungleich verteilt sind, kann der Schaltschrank umkippen.
Bauen Sie das System deshalb ganz unten im Schrank ein, wenn es das einzige System im
Schrank ist. Wenn mehrere Systeme in einen Schrank eingebaut werden sollen, plazieren Sie
das schwerste System ganz unten und die leichteren weiter oben. Falls der Schaltschrank mit
Kippsicherungen ausgestattet ist, stellen Sie sicher, dass diese auch installiert und ausgefahren
sind, um einen sicheren Stand des Schranks zu gewährleisten. Beginnen Sie erst danach mit
dem Einbau oder der Wartung des Systems.
Verletzungsgefahr oder Beschädigung des Systems
Das System kann beim Herausziehen herunterfallen und Verletzungen verursachen.
Ziehen Sie das System vorsichtig heraus, damit es nicht herunterfällt.
Verletzungsgefahr oder Beschädigung des Systems
Das System ist schwer, und wenn Sie es alleine tragen, kann dies zu Rückenschäden führen.
Heben Sie deshalb das System nur zu zweit und halten Sie beim Heben Ihren Rücken gerade
oder benutzen Sie zusätzliche Hilfsmittel.
Beschädigung des Systems
Während des Transportes und Zusammenbaus des Systems können sich Teile, wie zum
Beispiel Schrauben, Blenden, Stecker oder Lüfter lösen oder beschädigt werden.
Nehmen Sie das System nicht in Betrieb, wenn Teile beschädigt sind. Dies könnte zu
Beschädigungen an anderen Teilen führen.
Hoher Ableitstrom
Dieser Aufkleber befindet sich in der Nähe der Schuzleiter auf der Rückseite des Systems und
warnt, dass Sie vor der Inbetriebnahme eine Erdung durchführen müssen, da hier ein hoher
Ableitstrom vorhanden sein kann.
AXP640 Safety Notes Summary (6806800T70A)
21
Sicherheitshinweise
Hoher Ableitstrom kann zu Verletzungen führen.
Stellen Sie deshalb vor Anschluss des Systems an ein Telekommunikationsnetz unbedingt eine
Erdungsverbindung her.
Beschädigung des Systems
Falsche Jumper-Einstellungen können dazu führen, dass das System nicht mehr funktioniert.
Ändern Sie deshalb nie die Einstellungen der Jumper.
Board und RTM Installation
Beschädigung des Boards
Berühren Sie das Board oder elektrische Komponenten in einem nicht ESD-geschützten
Bereich, kann dies zu einer Beschädigung des Boards führen.
Bevor Sie Boards oder elektronische Komponenten berühren, vergewissern Sie sich, dass Sie in
einem ESD-geschützten Bereich arbeiten.
Reihenfolge bei der Installation von RTMs und AdvancedTCA Boards
Die folgende Reihenfolge muß bei der Installation von RTMs und AdvancedTCA Boards
eingehalten werden:
Installieren Sie zuerst das RTM und erst danach das passende AdvancedTCA Board. Ansonsten
können RTM oder Board beschädigt werden.
Beschädigung des Boards oder Systems
Wird ein Board in den falschen Steckplatz im System gesteckt, können sowohl das Board als
auch das System beschädigt werden. Installieren Sie Boards deshalb ausschließlich in dafür
vorgesehene Steckplätze.
Beschädigung des RTMs oder Boards
Wird das RTM ausgebaut, während die Payload des dazugehörigen AdvancedTCA Boards noch
nicht heruntergefahren ist, kann dies zu Beschädigungen am Board oder RTM führen.
Fahren Sie deshalb die Payload des AdvancedTCA Blades immer herunter, bevor Sie das
dazugehörige RTM aus dem System entfernen.
22
AXP640 Safety Notes Summary (6806800T70A)
Sicherheitshinweise
Beschädigung des RTMs
Fehlerhafte Installation kann zu einer Beschädigung des RTMs führen. Verwenden Sie die
Handles, um das RTM zu installieren/deinstallieren. Auf diese Weise vermeiden Sie, dass die
Frontblende oder die Platine deformiert oder zerstört werden.
Beschädigung des RTMs oder Boards
Das System wird beschädigt, wenn die RTMs nicht zu den von vorne in dem System
installierten Boards passen.
Stellen Sie deshalb sicher, dass Boards und RTMs, die von vorne bzw. von hinten in den gleichen
Steckplatz des Systems eingebaut werden, stets zueinander passen.
Datenverlust
Das Entfernen eines RTMs während des Systembetriebs und blinkender blauer LED des Front
Boards führt zu Datenverlust.
Vor dem Entfernen des RTMs im laufenden Systembetrieb, schalten Sie das entsprechende
Board ab, indem Sie die Griffe des Boards öffnen. Warten Sie, bis die blaue LED dauerhaft
leuchtet.
Fehlfunktion
Unsachgemäßer Ein- und Ausbau von Boards kann zu einer Fehlfunktion des Boards führen.
Vergewissern Sie sich, dass das Board über alle Stecker an die AdvancedTCA-Backplane
angeschlossen und die Stromversorgung gewährleistet ist.
Betrieb
Überhitzung des Systems
Lüftungsschlitze
Unzureichende Lüftung kann Schäden an Boards und am System verursachen.
AXP640 Safety Notes Summary (6806800T70A)
23
Sicherheitshinweise
Um eine ausreichende Lüftung zu gewährleisten, stellen Sie sicher, dass das System während
des Betriebs stets waagerecht steht und dass ein Freiraum von mindestens 60 mm an der
Rückseite des Systems vorhanden ist. Halten Sie die Lüftungsschlitze an der Oberseite und der
Rückseite des Systems frei. Halten Sie die Frischluftzufuhröffnung an der unteren Vorderseite
des Systems völlig frei und stellen Sie sicher, dass sich die Frischluft nicht mit der Abluft von
anderen Systemen mischt.
Um eine ungestörte Luftzirkulation zu gewährleisten, stellen Sie sicher, dass alle Steckplätze
mit Boards oder Platzhaltern belegt sind.
Beschädigung des Systems
Durch hohe Luftfeuchtigkeit können Kurzschlüsse entstehen.
Betreiben Sie das System nur innerhalb der angegebenen Grenzwerte für die relative
Luftfeuchtigkeit und Temperatur. Stellen Sie vor dem Einschalten des Stroms sicher, dass sich
auf dem System und auf den Boards kein Kondensat befindet und starten Sie das System nicht
unter 0ºC.
Stromschlaggefahr
Das System besitzt vier -48V bis -60V DC Anschlüsse. Alle Anschlüsse müssen vom System
entfernt werden, um das System spannungsfrei zu schalten.
Um eine Verletzungsgefahr zu minimieren, entfernen Sie die Anschlüsse, wenn Sie das System
ausschalten.
Beschädigung des Systems
Luftfilter
Verunreinigungen in der Luft können den Luftfilter verschmutzen und so die Luftzufuhr des
Systems beeinträchtigen. Das kann zur Überhitzung des Systems und zu Schäden an
Systemteilen führen.
Um einen reibungslosen Luftstrom durch das System zu gewährleisten, sollten Sie den
Luftfilter spätestens alle sechs Monate austauschen. Artesyn empfiehlt, die Lüfter alle 90 Tage
auszutauschen. Wie häufig Sie die Filter austauschen müssen, hängt von der Umgebung ab, in
der das System betrieben wird. Da die Verhältnisse in Vermittlungsstellen sehr unterschiedlich
sein können, sollten Sie die Luftfilter nach der Erstinstallation des Systems jede Woche
kontrollieren. In einer staubigen Umgebung muss ein Filter gegebenenfalls öfter gereinigt
24
AXP640 Safety Notes Summary (6806800T70A)
Sicherheitshinweise
werden als in einer sauberen Umgebung. Prüfen Sie den Filter regelmäßig bis Sie eine
Vorstellung davon haben, wie oft der Filter gereinigt werden muss. Erstellen Sie aufgrund Ihrer
Beobachtungen einen Reinigungsplan und protokollieren Sie jede Reinigung oder jeden
Austausch des Filters.
Überhitzung des Systems
Wenn Sie die Geschwindigkeit der Lüfter reduzieren, steigt die Systemtemperatur an.
Kontrollieren Sie deshalb ständig die Temperatur im System, wenn Sie die Geschwindigkeit der
Lüfter reduziert haben. Stellen Sie während des Betriebs sicher, dass die Bedingungen, die im
Handbuch beschrieben sind, eingehalten werden.
Verletzungen oder Kurzschlüsse
Blade oder Stromversorgung
Falls die ORing Dioden des Blades durchbrennen, kann das Blade einen Kurzschluss zwischen
den Eingangsleitungen A und B verursachen. In diesem Fall ist Leitung A immer noch unter
Spannung, auch wenn sie vom Versorgungskreislauf getrennt ist (und umgekehrt).
Prüfen Sie deshalb immer, ob die Leitung spannungsfrei ist, bevor Sie Ihre Arbeit fortsetzen,
um Schäden oder Verletzungen zu vermeiden.
Ausbau/Erweiterung
Systemüberlastung
Verhindern Sie eine Systemüberlastung, indem Sie die gesamte aufgenomme Leistung aller
eingebauten Komponenten, also z.B. der installierten Blades und Laufwerke (siehe die
technischen Daten der entsprechenden Komponente) überprüfen. Stellen Sie sicher, dass der
Ausgangsstrom jedes Verbrauchers innerhalb der zulässigen Grenzwerte liegt.
Verlust der Sicherheitszulassung
Verwendung zusätzlicher Module
Wenn Sie zusätzliche Module und Boards verwenden, ist es möglich, dass das System nicht
mehr den gültigen Sicherheits- und EMV Normen entspricht. Der Systemintegrator muss die
Einhaltung der gültigen Normen sicherstellen.
AXP640 Safety Notes Summary (6806800T70A)
25
Sicherheitshinweise
Austausch von PEMs
Verletzungsgefahr durch Stromschlag und Verbrennungen
Berühren metallische Gegenstände an Händen, Handgelenken oder am Hals die Input
Terminals der PEMs, kann dies zu extremen Verletzungen, wie zum Beispiel Verbrennungen
oder Amputationen führen. Tragen Sie bei der Arbeit mit dem System keine metallischen
Gegenstände an Ihren Händen oder Armen und lassen sie keine metallischen Gegenstände um
Ihren Hals hängen. Seien Sie extrem vorsichtig mit elektrisch leitenden Gegenständen in der
Nähe der PEMs.
Kurzschluß und Gefahr durch Stromschlag
Um einen elektrischen Schlag zu vermeiden, überzeugen Sie sich, dass vor dem Austausch des
PEMs die Stromzufuhr unterbrochen ist und während des Austausches unterbrochen bleibt.
Kurzschluß und Gefahr durch Stromschlag
Um Kurzschlüsse und elektrischen Schlag zu vermeiden, überzeugen Sie sich, dass vor dem
Lösen der Schrauben die Stromzufuhr unterbrochen ist und während des Austausches
unterbrochen bleibt. Vermeiden Sie Kurzschlüsse, indem Sie sehr vorsichtig mit dem
Werkzeug umgehen.
Beschädigung der Spannungsversorgungseinheit
Wir die Spannungsversorgungseinheit verkehrt angeschlossen, werden die
Elektrolytkondensatoren der Filter beschädigt. Schalten Sie die Unterbrecher deshalb nur,
wenn das rote Licht nicht sichtbar ist.
Lüfteraustausch
Verletzungsgefahr
Rotierende Lüfterschaufeln
Sie können verletzt werden, wenn Sie Werkzeuge oder Finger in laufende Lüfter einführen.
Wenn Sie die Lüfterschublade aus dem Chassis ziehen, wird die Abdeckung der Lüfterschaufeln
freigelegt. Berühren Sie die Lüfterschaufeln nicht.
Seien Sie vorsichtig nach dem Herausziehen des Lüfters, da die Zentrifugalkräfte noch wirken
und somit die Handhabung erschweren können.
26
AXP640 Safety Notes Summary (6806800T70A)
Sicherheitshinweise
Verkabelung/Kabelführung
Verletzungsgefahr
Verändern Sie nie die von Artesyn ausgelieferte Verkabelung des Systems.
Stellen Sie sicher, dass die Verkabelung schon existierenden Kabelführungen folgt und
bestehende oder ähnliche Befestigungen verwendet. Überprüfen Sie nach der Erweiterung der
Verkabelung, ob das System ordnungsgemäß arbeitet.
Reduzieren Sie die Verletzungsgefahr, indem Sie Kabel so verlegen, dass niemand darüber
stolpern kann.
Verletzungsgefahr durch Stromschlag
Durch das Berühren von Kontakten und Kabeln während des Betriebs können Sie einen
elektrischen Schlag bekommen.
Schließen Sie in jedem Fall aus, dass Personen durch einen elektrischen Schlag verletzt werden
können, indem Sie sicherstellen, dass Kontakte und Kabel des Systems während des Betriebs
nicht berührt werden können.
Falls Sie Fragen bezüglich der Verkabelung haben, wenden Sie sich an die für Sie zuständige
Geschäftsstelle von Artesyn.
Beschädigung der Kabel
Werden Kabel geknickt, kann das Kabel beschädigt werden und der Datentransfer nicht mehr
stattfinden. Stellen Sie sicher, dass Kabel nicht geknickt werden.
RJ-45 Stecker
Beschädigung des Systems
Bei den RJ-45 Steckern, die sich auf den Boards befinden, handelt es sich entweder um TwistedPair-Ethernet (TPE) oder um E1/T1/J1-Stecker. Beachten Sie, dass ein versehentliches
Anschließen einer E1/T1/J1 Leitung an einen TPE-Stecker Ihr System zerstören kann.

Kennzeichnen Sie deshalb TPE-Anschlüsse in der Nähe Ihres Arbeitsplatzes deutlich als
Netzwerkanschlüsse.

Stellen Sie sicher, dass die Länge eines mit Ihrem Systems verbundenen TPE-Kabels 100 m
nicht überschreitet.
AXP640 Safety Notes Summary (6806800T70A)
27
Sicherheitshinweise

Das System darf über die TPE Stecker nur mit einem Sicherheits-KleinspannungsStromkreis (SELV) verbunden werden.

Bei Fragen wenden Sie sich an Ihren Systemverwalter.
Laser
Verletzungsgefahr
Wenn sich an der Rückseite Ihres Systems ein Aufkleber mit der Aufschrift CLASS 1 LASER
PRODUCT befindet, beeinhaltet das System ein Bauteil mit einem Laser. Solche Bauteile
enthalten Laserdioden, die unsichtbare und für die Augen schädliche Laserstrahlen abgeben.
Falls Sie sich nicht an die Anweisung in diesem Handbuch halten, kann dies zu gefählichen
Strahlungsbelastungen führen. Schauen Sie niemals direkt in den Laserstrahl.
Batterieaustausch
Beschädigung der Boards
Ein unsachgemäßer Austausch von Batterien kann zu gefährlichen Explosionen und
Beschädigung der Boards führen.
Verwenden Sie deshalb nur den Batterietyp, der auch bereits eingesetzt wurde und befolgen
Sie die entsprechende Anleitung im Installationshandbuch des jeweiligen Boards.
Entsorgen sie alte Batterien entsprechend der in Ihrem Land gültigen Richtlinien.
Umweltschutz
Umweltschutz
Entsorgen Sie alte Blades, RTMs und Systeme gemäß der in Ihrem Land gültigen Gesetzgebung
und den Empfehlungen des Herstellers.
28
AXP640 Safety Notes Summary (6806800T70A)
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc.
All other product or service names are the property of their respective owners.
©
2015 Artesyn Embedded Technologies, Inc.