Download LONG RANGE CCD BAR CODE SCANNER USER'S MANUAL

Transcript
LONG RANGE CCD
BAR CODE SCANNER
USER’S
MANUAL
Contents
1. Introduction ...........................................................................................- 3 1.1 Installation .......................................................................................... - 3 • Unpacking .............................................................................................. - 3 • Connecting the scanner........................................................................ - 3 1.2 Default Setting .................................................................................... - 5 2. Setting Procedure .................................................................................- 6 2.1 Common setting ................................................................................. - 6 2.2 Parameter setting ............................................................................... - 7 2.3 Interface Selection ............................................................................. - 9 • Keyboard wedge.................................................................................. - 10 • RS232.................................................................................................... - 12 2.4 System setting.................................................................................. - 14 • Scan ...................................................................................................... - 14 • Indication.............................................................................................. - 16 3. Code Option.........................................................................................- 18 • Code 39................................................................................................. - 18 • Code 93................................................................................................. - 20 • Interleaved 2 of 5 ................................................................................. - 22 • Industrial 2 of 5 .................................................................................... - 24 • Standard 2 of 5..................................................................................... - 25 • Code 128............................................................................................... - 27 • CODABAR ............................................................................................ - 29 • EAN 8 .................................................................................................... - 31 • EAN13 ................................................................................................... - 33 • UPCA .................................................................................................... - 35 • UPCE..................................................................................................... - 37 • MSI ........................................................................................................ - 39 • PLESSEY .............................................................................................. - 41 • China post ............................................................................................ - 43 • Italian Pharmacode ( CODE 32 ) ......................................................... - 44 • Matrix 2 of 5.......................................................................................... - 45 • Telepen ................................................................................................. - 47 • CODE11 ................................................................................................ - 49 4. String setting / Transmission .............................................................- 51 • Prefix/Suffix.......................................................................................... - 51 • Preamble / Postamble ......................................................................... - 52 • Insert Group Character ....................................................................... - 53 • Others ................................................................................................... - 54 5. Scanner configuration / Reset to default settings............................- 56 Parameter list ..........................................................................................- 57 -
-2-
1. Introduction
Thank you very much for purchasing TSC bar code scanner.
This decoder is a Long Range (Gun Type) CCD Bar Code Scanner. It
works with variety of bar code types, reading devices and computer
interface. This manual provides an easy way to setting the decoder by
scanning bar codes listed on the menu.
Specifications, accessories, parts and programs are subject to change
without notice.
1.1 Installation
• Unpacking
Unpacking the box, the following items are included in the carton.
* One scanner unit
* One quick start guide
If any parts are missing, please contact the Customer Service
Department of your purchased reseller or distributor.
• Connecting the scanner
* USB interface
1. Turn off the power of terminal/computer.
2. Connect the USB cable to the scanner and the terminal/computer.
3. Turn the terminal/computer power on.
4. The scanner will beep a tone after connected.
5. Scan any bar code to ensure the scanner was completed setting.
* Keyboard wedge interface (Option)
1. Turn off the power of terminal/computer.
2. Connect the appropriate interface cable to the scanner, the
-3-
terminal/computer and keyboard.
3. Turn the terminal/computer power on.
4. The scanner will beep a tone after connected.
5. Set the scanner to keyboard wedge setting. (Please refer to section
2.1)
6. Scan any bar code to ensure the scanner completed setting.
* RS-232 interface (Option)
1. Turn off the power of terminal/computer.
2. Connect the RS-232 cable to the scanner and the terminal/computer.
3. Turn the terminal/computer power on.
4. The scanner will beep a tone after connected.
5. Set the scanner to RS-232 setting. (Please refer to section 2.1)
6. Scan any bar code to ensure for completed setting.
-4-
1.2 Default Setting
Code Type
Enable
Code 39
Code 93
Interleaved 2 of 5
Industrial 2 of 5
Standard 2 of 5
Code 128
Codabar
EAN 8
EAN 13
UPC A
UPC E
MSI
Plessey
China Post
Italian Pharmacode
(Code 32)
Matrix 2 of 5
Telepen
Code 11
X
Proprietary
ID
1
2
3
4
5
6
7
8
9
A
B
C
D
E
X
X
X
X
X
X
X
-5-
AIM Code ID
]A
]G
]I
]S
]R
]C
]F
]E
]E
]E
]E
]M
]P
]X
F
]G
G
H
I
]S
]B
]H
2. Setting Procedure
2.1 Common setting
Please follow below steps to set your scanner.
1. Scan the bar code from “Enter setting mode” side to start the setting
procedure.
2. Select the bar code from “Function” side to enter the option mode.
3. Scan the bar code from “Option” side to set the option function.
4. Scan the bar code from “Exit setting mode” side when finished the
setting.
Enter setting mode
1
*% $$PRO*
Function
Interface selection
2
Option
Remark
Default
Auto detection
3
Keyboard wedge
*% S1A*
RS232
USB
Exit setting mode
4
*$$% *
-6-
2.2 Parameter setting
Please follow below steps to set parameter setting.
1. Scan the bar code from “Enter setting mode” side to start the setting
procedure.
2. Select and scan the bar code from “Function” side to enter the option
mode.
3. Scan the bar code from the parameter list that listed on back page of
the manual to set the parameter.
4. Scan the bar code from “Exit setting mode” when finished the setting.
Enter setting mode
1
*% $$PRO*
Function
Stand-by duration
Option
1~99 sec
Remark
6 (Default)
*% SAB*
Double read timeout
2
1~99 (10 ms)
50 (Default)
0~9 times
0 (Default)
0~64
4 (Default)
0~64
63 (Default)
*% SAC*
Double confirm
*% SAD*
Global Min. code length
*% SAE*
Global Max. code length
*% SAF*
Exit setting mode
4
*$$% *
-7-
Parameter list (Listed on back page of the manual)
Parameter
Bar code
0
*/0*
1
*/1*
2
*/2*
3
*/3*
4
*/4*
5
*/5*
6
*/6*
7
*/7*
8
*/8*
9
*/9*
A
*/A*
B
*/B*
C
*/C*
D
*/D*
E
*/E*
F
*/F*
-8-
3
2.3 Interface Selection
Enter setting mode
*% $$PRO*
Function
Interface selection
Option
Auto detection
Keyboard wedge
*% S1A*
RS232
USB
Exit setting mode
*$$% *
-9-
Remark
Default
• Keyboard wedge
Enter setting mode
*% $$PRO*
Function
Keyboard type
Option
IBM AT, PS/2
Remark
Default
*% S2A*
Reserved
Keyboard layout
US international
Spanish
French
German
Italian
*% S2B*
Danish
Portuguese
Swedish
Switzerland
UK
- 10 -
Default
Latin American
Japanese
Hungarian
Reserved
Reserved
Keyboard speed
0~8
(0: High speed; 8: Low speed)
3
(Default)
*% S2C*
Caps lock
Caps lock “OFF”
Default
*% S2D*
Caps lock “ON”
Power-on simulation
Disable
Default
*% S2E*
Enable
Inter-character delay
0~99 (ms)
2
(Default)
0~99 (ms)
10
(Default)
*% S2F*
Block transmission delay
*% S2G*
Exit setting mode
*$$% *
- 11 -
• RS232
Enter setting mode
*% $$PRO*
Function
Flow control
(Handshaking)
Option
None
Remark
Default
RTS/CTS
*% S3A*
Xon/Xoff
ACK/NAK
Baud rate
1200 bps
2400 bps
4800 bps
*% S3B*
9600 bps
19200 bps
38400 bps
- 12 -
Default
57600 bps
115200 bps
Parity
None
Default
Odd
*% S3C*
Even
Data bit
8 bits
Default
*% S3D*
7 bits
Stop bit
1 bit
*% S3E*
2 bits
Exit setting mode
*$$% *
- 13 -
Default
2.4 System setting
• Scan
Enter setting mode
*% $$PRO*
Function
Scanning mode
Option
Remark
Good-read off
Momentary
*% SAA*
Default
Alternate
Continue
Timeout off
Stand-by duration
1~99 second(s)
6 (Default)
1~99 (10 ms)
50 (Default)
0~9 times
0 (Default)
0~64
4 (Default)
*% SAB*
Double read timeout
*% SAC*
Double confirm
*% SAD*
Global Min. code length
*% SAE*
- 14 -
Global Max. code length
0~64
63 (Default)
*% SAF*
Inverted image scan
Disable
Default
*% SAG*
Enable
Position indication
Disable
30 seconds
60 seconds
90 seconds
*% SAH*
120 seconds
150 seconds
180 seconds
Enable
Exit setting mode
*$$% *
- 15 -
Default
• Indication
Enter setting mode
*% $$PRO*
Function
Power on alert
Option
Remark
Disable
*% SBA*
Enable
Default
LED indication
Disable
*% SBB*
Enable
Default
Beeper indication
Disable
*% SBC*
Enable
Default
Beep loudness
0~7
7 (Default)
0~99(100 Hz)
26 (Default)
0~99(ms)
10 (Default)
*% SBD*
Beep tone frequency
*% SBE*
Beep tone duration
*% SBF*
- 16 -
Exit setting mode
*$$% *
- 17 -
3. Code Option
• Code 39
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% B1A*
Enable
Check-sum verification
Disable
Default
Default
*% B1B*
Enable
Check-sum transmission
Disable
Default
*% B1C*
Enable
Code ID setting
Hex 00-FF ASCII
1 (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
*% B1D*
Max. code length
*% B1E*
Min. code length
*% B1F*
Truncate leading
*% B1G*
- 18 -
Truncate ending
0-15
0 (Default)
*% B1H*
Start/End transmission
Disable
Default
*% B1J*
Enable
Insert group number
00-44
00 (Default)
*% B1M*
Format
( Standard Full ASCII )
Disable
*% B1R*
Enable
Exit setting mode
*$$% *
- 19 -
Default
• Code 93
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% B2A*
Enable
Check-sum verification
Disable
*% B2B*
Enable
Check-sum transmission
Disable
Default
Default
*% B2C*
Enable
Code ID setting
Hex 00-FF ASCII
2 (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
0-15
0 (Default)
00-44
00 (Default)
*% B2D*
Max. code length
*% B2E*
Min. code length
*% B2F*
Truncate leading
*% B2G*
Truncate ending
*% B2H*
Insert group number
*% B2M*
- 20 -
Exit setting mode
*$$% *
- 21 -
• Interleaved 2 of 5
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% B3A*
Enable
Check-sum verification
Disable
Default
Default
*% B3B*
Enable
Check-sum transmission
Disable
Default
*% B3C*
Enable
Code ID setting
Hex 00-FF ASCII
3 (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
0-15
0 (Default)
*% B3D*
Max. code length
*% B3E*
Min. code length
*% B3F*
Truncate leading
*% B3G*
Truncate ending
*% B3H*
- 22 -
Insert group number
00-44
*% B3M*
Exit setting mode
*$$% *
- 23 -
00 (Default)
• Industrial 2 of 5
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% B4A*
Enable
Code ID setting
Hex 00-FF ASCII
4 (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
0-15
0 (Default)
00-44
00 (Default)
*% B4D*
Max. code length
*% B4E*
Min. code length
*% B4F*
Truncate leading
*% B4G*
Truncate ending
*% B4H*
Insert group number
*% B4M*
Exit setting mode
*$$% *
- 24 -
• Standard 2 of 5
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% B5A*
Enable
Check-sum verification
Disable
Default
*% B5B*
Enable
Check-sum transmission
Disable
Default
*% B5C*
Enable
Code ID setting
Hex 00-FF ASCII
5 (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
0-15
0 (Default)
*% B5D*
Max. code length
*% B5E*
Min. code length
*% B5F*
Truncate leading
*% B5G*
Truncate ending
*% B5H*
- 25 -
Insert group number
00-44
*% B5M*
Exit setting mode
*$$% *
- 26 -
00 (Default)
• Code 128
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% B6A*
Enable
Default
Check-sum verification
Disable
*% B6B*
Enable
Check-sum transmission
Disable
Default
Default
*% B6C*
Enable
Code ID setting
Hex 00-FF ASCII
6 (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
*% B6D*
Max. code length
*% B6E*
Min. code length
*% B6F*
Truncate leading
*% B6G*
- 27 -
Truncate ending
0-15
0 (Default)
*% B6H*
Format
Standard
Default
*% B6R*
UCC/EAN-128
Append
Disable
Default
*% B6I*
Enable
UCC/EAN-128 ID setting
Hex 00-FF ASCII
6 (Default)
Hex 00-FF ASCII
1DH (Default)
00-44
00 (Default)
*% B6Y*
Field separator code
*% B6Z*
Insert group number
*% B6M*
Exit setting mode
*$$% *
- 28 -
• CODABAR
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% B7A*
Enable
Check-sum verification
Disable
Default
Default
*% B7B*
Enable
Check-sum transmission
Disable
Default
*% B7C*
Enable
Code ID setting
Hex 00-FF ASCII
7 (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
*% B7D*
Max. code length
*% B7E*
Min. code length
*% B7F*
Truncate leading
*% B7G*
- 29 -
Truncate ending
0-15
0 (Default)
*% B7H*
Start/End type
ABCD/ABCD
Default
abcd/abcd
*% B7S*
ABCD/TN*E
abcd/tn*e
Insert group number
00-44
00 (Default)
*% B7M*
Start/End transmission
Disable
*% B7J*
Enable
Exit setting mode
*$$% *
- 30 -
Default
• EAN 8
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% B8A*
Enable
Default
Check-sum transmission
Disable
*% B8C*
Enable
Default
Code ID setting
Hex 00-FF ASCII
8 (Default)
0-15
0 (Default)
0-15
0 (Default)
*% B8D*
Truncate leading
*% B8G*
Truncate ending
*% B8H*
Truncate leading zero
Disable
*% B8K*
Enable
- 31 -
Default
Supplement digits
None
Default
2 digits
*% B8O*
5 digits
Auto detection
Insert group number
00-44
*% B8M*
Exit setting mode
*$$% *
- 32 -
00 (Default)
• EAN13
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% B9A*
Enable
Default
Check-sum transmission
Disable
*% B9C*
Enable
Default
Code ID setting
Hex 00-FF ASCII
9 (Default)
0-15
0 (Default)
0-15
0 (Default)
*% B9D*
Truncate leading
*% B9G*
Truncate ending
*% B9H*
Truncate leading zero
Disable
*% B9K*
Enable
- 33 -
Default
Supplement digits
None
Default
2 digits
*% B9O*
5 digits
Auto detection
ISBN/ISSN
Disable
Default
*% B9T*
Enable
Insert group number
00-44
*% B9M*
Exit setting mode
*$$% *
- 34 -
00 (Default)
• UPCA
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% BAA*
Enable
Default
Check-sum transmission
Disable
*% BAC*
Enable
Default
Code ID setting
Hex 00-FF ASCII
A (Default)
0-15
0 (Default)
0-15
0 (Default)
*% BAD*
Truncate leading
*% BAG*
Truncate ending
*% BAH*
Truncation/ Expansion
None
*% BAL*
Not Send Zero
Expand to EAN13
- 35 -
Default
Supplement digits
None
Default
2 digits
*% BAO*
5 digits
UCC/EAN 128
Auto detection
Insert group number
00-44
*% BAM*
Exit setting mode
*$$% *
- 36 -
00 (Default)
• UPCE
Enter setting mode
*% $$PRO*
Function
Option
Remark
Read
Disable
*% BBA*
Enable
Default
Check-sum transmission
Disable
*% BBC*
Enable
Default
Code ID setting
Hex 00-FF ASCII
B (Default)
0-15
0 (Default)
0-15
0 (Default)
*% BBD*
Truncate leading
*% BBG*
Truncate ending
*% BBH*
Supplement digits
None
2 digits
*% BBO*
5 digits
UCC/EAN 128
Auto detection
- 37 -
Default
Insert group number
00-44
00 (Default)
*% BBM*
Expansion
Disable
Default
*% BBN*
Enable
UPCE-1
Disable
*% BBU*
Enable
Exit setting mode
*$$% *
- 38 -
Default
• MSI
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% BCA*
Enable
Check-sum verification
Disable
Mod 10
Default
*% BCB*
Mod 10/10
Mod 11/10
Check-sum transmission
Disable
Default
*% BCC*
Enable
Code ID setting
Hex 00-FF ASCII
C (Default)
0-64
0 (Default)
0-64
0 (Default)
*% BCD*
Max. code length
*% BCE*
Min. code length
*% BCF*
- 39 -
Truncate leading
0-15
0 (Default)
0-15
0 (Default)
00-44
00 (Default)
*% BCG*
Truncate ending
*% BCH*
Insert group number
*% BCM*
Exit setting mode
*$$% *
- 40 -
• PLESSEY
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% BDA*
Enable
Check-sum verification
Disable
*% BDB*
Enable
Check-sum transmission
Disable
Default
Default
*% BDC*
Enable
Code ID setting
Hex 00-FF ASCII
D (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
*% BDD*
Max. code length
*% BDE*
Min. code length
*% BDF*
Truncate leading
*% BDG*
- 41 -
Truncate ending
0-15
0 (Default)
00-44
00 (Default)
*% BDH*
Insert group number
*% BDM*
Exit setting mode
*$$% *
- 42 -
• China post
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% BEA*
Enable
Code ID setting
Hex 00-FF ASCII
E (Default)
0-64
11 (Default)
0-64
0 (Default)
0-15
0 (Default)
0-15
0 (Default)
00-44
00 (Default)
*% BED*
Max. code length
*% BEE*
Min. code length
*% BEF*
Truncate leading
*% BEG*
Truncate ending
*% BEH*
Insert group number
*% BEM*
- 43 -
• Italian Pharmacode ( CODE 32 )
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% BFA*
Enable
Code ID setting
Hex 00-FF ASCII
F (Default)
0-15
0 (Default)
0-15
0 (Default)
*% BFD*
Truncate leading
*% BFG*
Truncate ending
*% BFH*
Leading "A"
Disable
Default
*% BFP*
Enable
Insert group number
00-44
*% BFM*
Exit setting mode
*$$% *
- 44 -
00 (Default)
• Matrix 2 of 5
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% BGA*
Enable
Check-sum verification
Disable
Default
*% BGB*
Enable
Check-sum transmission
Disable
Default
*% BGC*
Enable
Code ID setting
Hex 00-FF ASCII
G (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
*% BGD*
Max. code length
*% BGE*
Min. code length
*% BGF*
Truncate leading
*% BGG*
- 45 -
Truncate ending
0-15
0 (Default)
00-44
00 (Default)
*% BGH*
Insert group number
*% BGM*
Exit setting mode
*$$% *
- 46 -
• Telepen
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% BHA*
Enable
Check-sum verification
Disable
Default
*% BHB*
Enable
Check-sum transmission
Disable
Default
*% BHC*
Enable
Code ID setting
Hex 00-FF ASCII
H (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
0-15
0 (Default)
*% BHD*
Max. code length
*% BHE*
Min. code length
*% BHF*
Truncate leading
*% BHG*
Truncate ending
*% BHH*
- 47 -
Insert group Number
00-44
00 (Default)
*% BHM*
Format
Numeric only
*% BHR*
Full ASCII only
Exit setting mode
*$$% *
- 48 -
Default
• CODE11
Enter setting mode
*% $$PRO*
Function
Option
Read
Disable
Remark
Default
*% BIA*
Enable
Check-sum verification
Disable
*% BIB*
One digit
Default
Two digit
Check-sum transmission
Disable
Default
*% BIC*
Enable
Code ID setting
Hex 00-FF ASCII
I (Default)
0-64
0 (Default)
0-64
0 (Default)
0-15
0 (Default)
*% BID*
Max. code length
*% BIE*
Min. code length
*% BIF*
Truncate leading
*% BIG*
- 49 -
Truncate ending
0-15
0 (Default)
00-44
00 (Default)
*% BIH*
Insert group number
*% BIM*
Exit setting mode
*$$% *
- 50 -
4. String setting / Transmission
• Prefix/Suffix
Enter setting mode
*% $$PRO*
Function
Prefix characters setting
Option
Remark
Hex 00-FF ASCII
1-22 characters
None (Default)
Hex 00-FF ASCII
1-22 characters
0D0AH (Default)
*% SZA*
Suffix characters setting
*% SZB*
Exit setting mode
*$$% *
- 51 -
• Preamble / Postamble
Enter setting mode
*% $$PRO*
Function
Preamble characters
setting
Option
Remark
Hex 00-FF ASCII
1-22 characters
None (Default)
*% SYA*
Preamble transmission
Disable
Default
*% SYB*
Enable
Postamble characters
setting
Hex 00-FF ASCII
1-22 characters
None (Default)
*% SYC*
Postamble transmission
Disable
*% SYD*
Enable
Exit setting mode
*$$% *
- 52 -
Default
• Insert Group Character
Enter setting mode
*% $$PRO*
Function
Insert G1 characters setting
*% SXA*
Insert G2 characters setting
*% SXB*
Insert G3 characters setting
Option
Remark
Hex 00-FF ASCII
1-22 characters
None (Default)
Hex 00-FF ASCII
1-22 characters
None (Default)
Hex 00-FF ASCII
1-22 characters
None (Default)
Hex 00-FF ASCII
1-22 characters
None (Default)
00-63
00: no insertion
(Default)
00-63
00: no insertion
(Default)
00-63
00: no insertion
(Default)
00-63
00: no insertion
(Default)
*% SXC*
Insert G4 characters setting
*% SXD*
Insert data group 1 position
*% SXE*
Insert data group 2 position
*% SXF*
Insert data group 3 position
*% SXG*
Insert data group 4 position
*% SXH*
Exit setting mode
*$$% *
- 53 -
• Others
Enter setting mode
*% $$PRO*
Function
Code ID position
Option
Before code data
Remark
Default
*% SWA*
After code data
Code ID transmission
Disable
*% SWB*
Default
Proprietary ID
AIM ID
Code length transmission
Disable
Default
*% SWC*
Enable
Code name transmission
Disable
Default
*% SWD*
Enable
Case conversion
Disable
*% SWE*
Upper case
Lower case
For barcode data only
- 54 -
Default
Exit setting mode
*$$% *
- 55 -
5. Scanner configuration / Reset to default settings
Enter setting mode
*% $$PRO*
Function
Barcode standard
parameter list
*% LP1*
Unique parameter list
*% LP2*
System parameter list
*% LP3*
String setting list
*% LP4*
Firmware version
*% LFV*
Description
After scan this barcode, the host
terminal/computer will display barcode
standard parameter list of the scanner.
After scan this barcode, the host
terminal/computer will display unique
parameter list of the scanner.
After scan this barcode, the host
terminal/computer will display system
parameter list of the scanner.
After scan this barcode, the host
terminal/computer will display string setting
list of the scanner.
After scan this barcode, the host
terminal/computer will display firmware
version of the scanner.
Reset to default settings
*% RES*
Initialize the scanner and restore the
settings to factory default.
Exit setting mode
*$$% *
- 56 -
Parameter list
Parameter
Bar code
0
*/0*
1
*/1*
2
*/2*
3
*/3*
4
*/4*
5
*/5*
6
*/6*
7
*/7*
8
*/8*
9
*/9*
A
*/A*
B
*/B*
C
*/C*
D
*/D*
E
*/E*
F
*/F*
- 57 -
P/N: 39-0000073-20LF