Download OPERATING INSTRUCTIONS
Transcript
GAS CONTINUOUS FLOW WATER HEATERS OPERATING INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6 2 OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS 1. Do not hang washing or other materials adjacent to the unit. 'RQRWVWRUHÀDPPDEOH materials within 2 metres of the unit. 'RQRWWRXFKWKHÀXHRXWOHWRIWKHXQLW during or immediately after operation. 4. If any gas smell comes from the unit, GRQRWXVHQDNHGÀDPHVWRWHVWIRUJDVOHDNV Turn off the gas supply and power and FRQWDFW\RXUSOXPEHURU5HHFH&XVWRPHU Care on 1800 080 055. CLOSE No Fire Prohibited 5. If a power failure occurs the remote controls will not function and the Thermann unit will not supply hot water until power is restored. OPERATING INSTRUCTIONS 3 IMPORTANT SAFETY INSTRUCTIONS MEASURES TO BE TAKEN DURING ELECTRICAL STORMS 3RZHUVXUJHVFDXVHGE\OLJKWQLQJFDQGDPDJHWKHHOHFWURQLFSDUWV7KHUHIRUHWXUQRII the main power during electrical storms DO NOT INSTALL INDOORS Danger 0D\FDXVHR[\JHQGH¿FLHQF\DFFLGHQWRULQFRPSOHWH FRPEXVWLRQ This unit is designed for outdoor installation. Never install LQGRRUV,WZLOOEHH[WUHPHO\GDQJHURXVEHFDXVHLWZLOOFDXVH R[\JHQGH¿FLHQF\DQGLQFRPSOHWHFRPEXVWLRQ ,IWKHXQLWKDVEHHQLQVWDOOHGLQGRRUVWXUQRIIWKHJDVVXSSO\DQG FRQWDFW\RXUSOXPEHULPPHGLDWHO\ SECURE SERVICE SPACE Make sure there is enough space around the unit for checking, service and maintenance. Check 4 OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS DO NOT DISASSEMBLE, REPAIR OR MODIFY Warning 'RQRWGLVDVVHPEOHRUPRGLI\WKHXQLWV$VWKLV PD\FDXVH¿UHHOHFWULFVKRFNDQGRWKHUDFFLGHQWV $OZD\VXVHDOLFHQVHGSOXPEHUIRULQVWDOODWLRQ relocation or connection to solar units. FLAMMABLE ITEMS Warning 0D\FDXVH¿UHRUH[SORVLRQ 'RQRWSODFHDQ\ÀDPPDEOHLWHPVQHDUWKHXQLW or use them around the unit. FREEZE PREVENTION This unit comes equipped with internal electric heaters that prevent the water inside the unit from freezing. 7RHQDEOHWKLVIUHH]HSUHYHQWLRQV\VWHPWRRSHUDWHWKHUHPXVWEHDQHOHFWULFDO power supply connected to the unit. The freeze prevention devices will not operate if the electrical power source is not connected. The electric defrost heaters are installed inside the water heater only. $OO([WHUQDO+RWDQG&ROGZDWHUVXSSO\SLSHVDQG¿WWLQJVFRQQHFWHGWR WKHZDWHUKHDWHUVKRXOGEHSURSHUO\LQVXODWHG WATER INLET PRESSURE Maximum working water pressure is 1200kPa CAUTION TO PREVENT SCALDING &KHFNWKHZDWHUWHPSHUDWXUHE\KDQG ¿UVWEHIRUHXVLQJVKRZHU Caution OPERATING INSTRUCTIONS 5 IMPORTANT SAFETY INSTRUCTIONS MEASURES TO BE TAKEN IN CASE OF EMERGENCY The procedure to follow in an emergency such as HDUWKTXDNHÀRRGRU¿UHLV Close Close 1. Close all hot water taps in the house. 2. Close the gas valve and the main water valve. 3. Turn off the main power.** ,QFDVHRIJDVOHDNDJH¿UVWFORVHWKHJDVYDOYHWKHQZDLWIRUWKH leaked gas to disperse then turn off the main power supply** This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. ELECTRICAL CONNECTION DANGER OF WET HANDS Do not touch power plug with wet hands. It can cause electric shock. Caution Warning INSERT POWER PLUG FULLY INTO POWERPOINT Check that the power plug is clean and undamaged, then fully insert into the power point. Check DO NOT PULL POWER CORD 'RQRWUHPRYHWKHSRZHUSOXJE\SXOOLQJWKHFRUG DVLWPD\JHQHUDWHKHDWE\ZLUHEUHDNDJHDQGFDXVH ¿UH+ROGWKHSOXJZKHQUHPRYLQJWKHSRZHUFRUG 3URKLELWHG DO NOT USE POWER CORD BUNDLED 1HYHUXVHSRZHUFRUGLQDEXQGOHGFRQGLWLRQ ,WPD\FDXVHKHDWJHQHUDWLRQDQG¿UH 3URKLELWHG DO NOT REPLACE POWER CORD ,IWKHSRZHUVXSSO\FRUGLVGDPDJHGLWVKRXOGEHUHSODFHGE\DFRUGDYDLODEOH IURP5((&(DJHQWV7KHSRZHUFRUGPXVWEHUHSODFHGE\DQDXWKRULVHGSHUVRQWR prevent accidents. 6 OPERATING INSTRUCTIONS REMOTE CONTROL 8SWRWKUHHUHPRWHFRQWUROVDUHDEOHWREHLQVWDOOHGZLWK\RXU7KHUPDQQXQLWIRU complete control of your hot water. 3OHDVHQRWHXQLWVZLWKRXWUHPRWHFRQWUROZLOOEHVHWDWHLWKHU&RU& WKHH[FHSWLRQLVLIWKHXQLWLVLQVWDOOHGDVDVRODUERRVWHU<RXUSOXPEHUZLOOKDYHVHW WKHXQLWWR& YST-2807 8QLYHUVDO&RQWUROOHU 7KLVUHPRWHFRQWUROOHULVLQWHQGHGWREHXVHGLQWKHNLWFKHQODXQGU\URRPEDWKURRP and ensuite. High Temp. Indicator Indicates the setting temperature is higher than 50゜ C. Digital Monitor Indicates the selected water temperature. Error messages flash in the event of failure. UP/DOWN Button Increase or decrease the desired water temperature. In Use Indicator Indicates that a hot water tap is open. ON Indicator Indicates power is on to the system. PRIORITY Indicator Indicates this controller has priority control over by controller. ON/OFF Button Power switch to operate this remote controller. PRIORITY Button PRIORITY Button to set the water temperature on this remote controller. 7KHXQLWZLOOGHOLYHUWKHVHOHFWHGWHPSHUDWXUHDVIROORZV Kitchen Controller: DQG& Bathroom Controller: & 2QO\IRU&PRGHO OPERATING INSTRUCTIONS 7 REMOTE CONTROL Operation of Controller 3OHDVHUHDGWKHVHLQVWUXFWLRQVFDUHIXOO\EHIRUHXVLQJWKLVDSSOLDQFH 7XUQRQWKH212))EXWWRQ 7KHWHPSHUDWXUHGLVSOD\ZLOOUHDG& 3. The priority indicator will illuminate. 6HOHFWKRWZDWHUWHPSHUDWXUHE\SXVKLQJ or EXWWRQRQWKHFRQWUROOHU 5. Turn on the hot water tap or shower. The ``In Use´´ indicator will illuminate after a short delay. This indicator will remain illuminated until the hot water tap or shower is turned off. 7KHKRWZDWHUWHPSHUDWXUHFDQEHDOWHUHGDWDQ\WLPHGXULQJWKHRSHUDWLRQE\ or EXWWRQ located on the controller. pushing Controller Energy-saving Mode If no data is adjusted within a period of approximately 5 minutes the display EHFRPHVGLP7KLVLVHQHUJ\VDYLQJPRGHDQGQRWDIDLOXUH 8 OPERATING INSTRUCTIONS REMOTE CONTROL Priority Control (Change) 7KHWHPSHUDWXUHFDQRQO\EHFRQWUROOHGE\WKHUHPRWHFRQWUROOHUZKLFKKDVWKHSULRULW\ indication. :KHQWKHSULRULW\EXWWRQLVWXUQHG21WKDWFRQWUROOHUWDNHVSULRULW\FRQWURORYHUWKH WHPSHUDWXUHVHWWLQJV'XULQJKRWZDWHUVXSSO\RWKHUUHPRWHFRQWUROOHUVFDQQRWEH WXUQHGRII Whilst hot water outlets are open, transfer of ``priority´´ to other remote controllers is QRWSRVVLEOH7KLVLVVDIHW\IHDWXUH Warning Do not turn off the remote controller or change the water temperature while someone is bathing or washing. That may result in scalds or burns. HINTS FOR USING REMOTE CONTROLS FOR SAFETY AND ENERGY SAVINGS 6 HWWKHFRQWUROOHUWRDPD[LPXPRI&IRUQRUPDOEDWKURRPXVHDQGWR prevent small children from scalding. ) RUNLWFKHQDQGODXQGU\XVHVHWWKH0$,1&21752/WR&RUWKHGHVLUHG temperature. ) RUVKRZHULQJXVHVHWWLQJVEHWZHHQ&&DQGQRFROGZDWHUZLOO EHQHHGHGWREHPL[HGDQGLIRWKHUKRWRUFROGZDWHUWDSVDUHXVHGWKH WHPSHUDWXUHZLOOEHPDLQWDLQHG : KHQEDWKURRPUHPRWHFRQWUROOHULVWXUQHG21WKHWHPSHUDWXUHFDQEH DGMXVWHGEHWZHHQ&& 8372&7+(7(03(5$785(:,//,1&5($6(%<&:,7+($&+ 35(662)7+(83'2:1%8772167+(7(03(5$785(&$1%( $'-867('&217,18286/<%<.((3,1*7+(%8772135(66(' %(7:((1&$1'&7+(7(03(5$785(,6&21752//(' %<&,1&5(0(1763/($6(127($%29(&6&$/',1*&$12&&85 WITHIN SECONDS. OPERATING INSTRUCTIONS 9 FAULT MONITOR When installed with remote controllers the THERMANN HOT WATER UNIT HAS A SELF DIAGNOSING FUNCTION FOR FAULTS. When the unit does not operate correctly an error code is displayed on the remote FRQWURO7(03(5$785(',63/$<,1',&$725 7KHFDXVHRIWKHIDXOWFDQEHGHWHUPLQHGDIWHUFKHFNLQJWKHIDXOWQXPEHUVGLVSOD\RQ the remote control display. DISPLAY PROBLEM REMEDY 111 *$6%851(5)$,/672,*1,7( &+(&.*$66833/< 121 /2662)&20%867,21 &+(&.*$66833/<$1' PRESSURE 141 5(6,'8$/)/$0(6$)(7< '(9,&( CALL REECE CUSTOMER CARE 1800 080 055 311, 321, 341 7+(50,6725:,5(%5($.$*( CALL REECE CUSTOMER CARE 1800 080 055 510, 511 *$69$/9()$,/85( CALL REECE CUSTOMER CARE 1800 080 055 611 &20%867,21)$1)$,/85( CALL REECE CUSTOMER CARE 1800 080 055 651 :$7(5)/2:&21752/9$/9( FAILURE CALL REECE CUSTOMER CARE 1800 080 055 700, 731 3&%)$,/85( CALL REECE CUSTOMER CARE 1800 080 055 721 FALSE FLAME DETECTION CALL REECE CUSTOMER CARE 1800 080 055 735 CASCADE COMMUNICATION FAILURE CALL REECE CUSTOMER CARE 1800 080 055 740, 750, 760 COMMUNICATION FAILURE %(7:((15(027(&21752/6 $1'3&% TURN OFF POWER AND TURN ON AGAIN MAINTENANCE 7KHVHXQLWVFDQEHFOHDQHGXVLQJZDUPVRDS\ZDWHUDQGDVRIWFORWK8QLWVKRXOGEH kept free of insect infestations. 127('RQRWVSUD\FKHPLFDOLQVHFWLFLGHVGLUHFWO\LQWRRURQWRWKHXQLW 0DLQWDLQDOOSODQWJURZWKWRHQVXUHLWGRHVQRWHIIHFWWKHRSHUDWLRQRIWKHXQLWE\ EORFNLQJRULQWHUIHULQJZLWKDLULQWDNHRUÀXHWHUPLQDO It is recommended the unit is checked for safe operation with an annual service. 6HUYLFLQJVKRXOGRQO\EHFDUULHGRXWE\DXWKRUL]HGSHUVRQQHOVXFKDVDOLFHQVHG tradesman. For servicing and spare parts information contact Reece Customer Care on 1800 080 055. 10 OPERATING INSTRUCTIONS WARRANTY Warranty Conditions 7KLVZDUUDQW\ZLOODSSO\RQO\XQGHUDOORIWKHIROORZLQJFRQGLWLRQV 7KHLWHPKDVEHHQLQVWDOOHGE\DOLFHQVHGSOXPEHU Failure is due to a fault in the manufacture of the product 3URRIRISXUFKDVHLQFOXGLQJWKHGDWHRISXUFKDVHLVSURYLGHG The installation of the product is in accordance with the instructions provided 7KLVZDUUDQW\GRHVQRWFRYHUSURGXFWVSXUFKDVHGDVDQH[GLVSOD\ZLWKRXWEHLQJ IXOO\FKHFNHGDQGWHVWHGIRUVDOHE\WKHPDQXIDFWXUHU This warranty does not include faults caused by: 8QVXLWDEOHRULPSURSHUXVH Incorrect installation or installation not in accordance with the instructions provided ,QVWDOODWLRQRUSDUWLQVWDOODWLRQE\WKHSXUFKDVHURUDQ\SHUVRQRWKHUWKDQD /,&(16('3/80%(5RUWUDGHVSHUVRQOLFHQVHGWRLQVWDOOWKLVSURGXFW Normal wear and tear Inadequate or complete lack of maintenance &KHPLFDOHOHFWURFKHPLFDORUHOHFWULFDOLQÀXHQFHV +DUVKGHWHUJHQWVRUDEUDVLYHFOHDQHUVXVHGRQSURGXFW¿QLVKHV EXCLUSIONS 7RWKHIXOOHVWH[WHQWSHUPLWWHGE\ODZ5HHFHH[FOXGHVDOOOLDELOLW\IRUGDPDJHRULQMXU\ to any person, damage to any property, and any indirect consequential or other loss or damage. CLAIM PROCEDURE )RUDOOZDUUDQW\TXHULHVFXVWRPHUVDUHWRFRQWDFWWKHEUDQFKZKHUHWKHSURGXFWZDV SXUFKDVHG7KHVHGHWDLOVFDQEHIRXQGRQ\RXUSXUFKDVHLQYRLFH 2XUJRRGVFRPHZLWKJXDUDQWHHVWKDWFDQQRWEHH[FOXGHGXQGHUWKH$XVWUDOLDQ &RQVXPHU/DZ<RXDUHHQWLWOHGWRDUHSODFHPHQWRUUHIXQGIRUDPDMRUIDLOXUHDQG IRUFRPSHQVDWLRQIRUDQ\RWKHUUHDVRQDEO\IRUHVHHDEOHORVVRUGDPDJH<RXDUHDOVR HQWLWOHGWRKDYHWKHJRRGVUHSDLUHGRUUHSODFHGLIWKHJRRGVIDLOWREHRIDFFHSWDEOH quality and the failure does not amount to a major failure. OPERATING INSTRUCTIONS 11 WARRANTY $OO7KHUPDQQZDWHUKHDWHUVPXVWEHLQVWDOOHGLQDFFRUGDQFHZLWKPDQXIDFWXUHU¶V LQVWDOODWLRQLQVWUXFWLRQVDQGLQDFFRUGDQFHZLWKORFDOUHJXODWLRQVEXLOGLQJFRGHV and AS/NZS3000, AS/NZS3500 and AS/NZS5601. Where a component may have failed under warranty and is replaced, the component UHSODFHGZLOORQO\EHFRYHUHGE\WKHZDUUDQW\IRUWKHEDODQFHRIWKHDSSOLDQFH warranty period. :DWHU4XDOLW\PXVWEHZLWKLQOLPLWVVSHFL¿HGLQWDEOHEHORZ pH 6.5 to 8.5 Sodium Up to 150 mg/litre or ppm 7'67RWDO'LVVROYHG6ROLGV Up to 600 mg/litre or ppm Chlorides Up to 300 mg/litre or ppm Iron Up to 1 mg/litre or ppm Magnesium Up to 10 mg/litre or ppm $ONDOLQLW\DV&D&2 Up to 200 mg/litre or ppm 'LVVROYHGIUHH&2 Up to 25 mg/litre or ppm Total Hardness CaCO3 Up to 200 mg/litre or ppm Warranty Terms 7KHUPDQQ*DV&RQWLQXRXV)ORZ+RW:DWHU8QLWVDUHFRYHUHGE\5HHFHIRUDQ\FRVW RIODERXUDQGSDUWVLQWKHHYHQWRIDFRPSRQHQWIDLOXUHGXHWRDQ\GHIHFWVWKDWPD\ arise either from workmanship and/or faulty material. The Warranty commences on the date of Installation: Domestic Heat Exchanger 10 years parts $OOFRPSRQHQWV \HDUVSDUWVODERXU Commercial $OOFRPSRQHQWV 12 \HDUSDUWVODERXU OPERATING INSTRUCTIONS www.thermann.com.au Works for you.™ 0