Download Warning Introduction Specifications Installation
Transcript
Communication Message type Communication Ports on IFD9503 PDO, SDO, SYNC (synchronous object), Emergency (emergency object), NMT Series transmission speed 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps (bits per second) Equipment type 0 (Non-Profile) Company ID 477 (Delta Electronics, Inc.) PORT 1 Sketch Voltage 11 ~ 25VDC Current 28mA (typical), 125mA impulse current (24VDC) Environment Storage: -25°C ~ 70°C (temperature), 5 ~ 95% (humidity) N.C. 2 PORT 2 Sketch 1 6 2 7 3 8 4 9 5 EFT (IEC 61131-2, IEC 61000-4-4): Analog & Communication I/O: 1KV ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge CE, UL Installation & Wiring Install IFD9503 in an enclosure with sufficient space around it to allow heat dissipation (see the figure). DO NOT place the I/O signal wires and power supply wire in the same wiring circuit. <1.5mm Introduction Shielded cable CAN_H Signal+ 5 V+ 24VDC 1 2 3 4 5 Functions & Services Supported 1 345 789 Setup range: 01 ~ 7F (00 and 80 ~ FF are forbidden) H 16 6 0 Example: If you need to set the node address of IFD9503 to 26 (H1A), simply switch the corresponding rotary switch ×161 to “1” and the corresponding rotary switch ×160 to “A”. Description 01 ~ 7F Valid CANopen node address 00, 80 ~ FF Invalid CANopen node address Note: The changed value on the switch is only valid when IFD9503 is re-powered. When IFD9503 is operating, changing the set value of the communication address will be invalid. The DIP switch is to be used on the equipment connected to IFD9503, the selection of communication ports and setting up the communication speed of IFD9503 and the master station in CANopen. PIN2 PIN3 PIN1 PIN2 PIN3 ON OFF OFF AC motor drive ON OFF ON Human machine interface ON OFF PLC OFF ON ON Custom equipment f Process Data Object (PDO) f Network Management (NMT) ON ON OFF Temperature controller OFF OFF OFF Many MODBUS devices OFF OFF ON Servo drive ON ON ON For internal system use Example: 5 2 3 6 7 4 9 8 10 Unit: mm 1 2 3 4 5 6 7 8 k l Communication port Address setup rotary switch Function setup DIP switch Instructions on the DIP switch Electrical isolation PIN4 PIN5 PIN4 PIN5 Communication Mode OFF OFF RS-485 ON OFF Incorrect setting ON ON RS-232 OFF ON Incorrect setting 500VDC Communication Mode DIN rail Note: The changed setting of the communication mode is only valid when IFD9503 is re-powered. When IFD9503 is operating, changing the setting of the communication mode will be invalid. DIN rail clip f Setting up Baud Rate Type Removable connector (5.08mm) Transmission cable 2 communication cables, 2 power cables and 1 shielded cable N.C. N.C. f CAN2.0A 協定 f CANopen DS301 V4.02 5 GND N.C. f 處理資料 物件 (PDO) 6 N.C. N.C. f 網路管理 物件 (NMT) N.C. N.C. 8 N.C. DATA+ 9 N.C. N.C. f 服務資料 物件 (SDO) 產品外觀及各部介紹 1 Indication No power How to deal with it Check the power of IFD9503 and make sure the connection is normal. PIN6 PIN7 PIN8 9 8 10 Green light single flash Stop --- Green light blinking Pre-operation --- Green light ON Operating --- Red light ON Incorrect node address Set the node address of IFD9503 to be in the range 1 ~ 127. 尺寸單位: mm 通訊口 位址設定 開 關 功能設定 開 關 (DIP) 功能設定 開 關說明 SCAN 指示 燈 RUN 指 示燈 ERROR 指 示燈 CANopen 通訊連接 器 DIN 軌槽 DIN 軌固定 扣 功能規格 LED Status Indication How to deal with it 傳輸方式 CAN OFF No error IFD9503 operation is normal. 電氣隔離 500VDC Red light single flash Bus error and exceeds alarm leval Check if the network connection and the operation environment are normal. 接頭 可插拔式 連 接器 (5.08mm) 傳輸電纜 2 條通訊線 、2 條電源 線和 1 條遮 蔽線 Indication How to deal with it Red light double flash Error control event occurs. Check if the communication between IFD9503 and the master station is normal. Red light ON BUS OFF 1. Check if the BUS connection is normal. 2. Re-power IFD9503. SCAN LED LED Status Indication How to deal with it OFF No power Check the power of IFD9503 and make sure the connection is normal. Green light flash The correct information of the equipment connected has not been detected. Re-connect IFD9503 to the equipment. Green light ON The communication with the equipment connected is normal. Red light flash 1. CRC check fails 2. Part of the MODBUS devices connected to IFD9503 is off-line (when IFD9503 in one-to-many mode) 1. Check if the communication cable between IFD9503 and the equipment is correct. 2. Check if there is electromagnetic interference nearby. Red light ON 1. Connection fails, or no connection 2. Part of the MODBUS devices connected to IFD9503 is off-line (when IFD9503 in one-to-many mode) 1. Check if the communication format of the equipment is correct. 2. Check if IFD9503 and the equipment are correctly connected. 3. Restart the connection and make sure the communication cable meets the specification. 通訊 資訊類型 PDO、SDO、SYNC( 同步物件 )、Emergency(緊急物 件)、NMT 串列傳輸 速 率 支援 10k、20k、50k、125k、250k、500k、800k、1M bps(位元∕ 秒 ) 設備類型 0 (Non-Profile) 廠商 ID 477(台達 電子) 電氣規格 電壓規格 11 ~ 25VDC 電流規格 28mA( 典 型值),125mA 衝擊電 流 (24VDC) 環境規格 IEC 61131-2,UL508 標準 標準 操作∕儲 存 環境 儲存:-25°C ~ 70°C(溫 度),5 ~ 95%(濕度) 操作:0°C ~ 55°C(溫 度),5 ~ 95%(濕度 ),污 染等級 2 國際標準 規 範 IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27 (TEST Ea) 耐振動∕ 衝 擊 RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 1000MHz, 10V/m EFT (IEC 61131-2, IEC 61000-4-4): Analog & Communication I/O: 1KV 雜訊免疫 力 ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge CE 認證、UL 認證 認證項目 盤內安裝及配線 IFD9503 在安裝時 , 請裝配於 封 閉式之控 制 箱內,其 周 圍應保持 一定之空 間 (如右圖 所 示), 以確 保 IFD9503 散熱功能 正 常。 在配線 時 請勿將輸 入 點信號線 與 輸出點或 電 源等動力 線 配置於同 一線槽內 。 28-12AWG 輸出/入 配 線端請使用 28-12AWG(1.5mm) 單蕊祼線 或 多蕊線, 端 子規格 如左所示 。 IFD9503 端子螺絲 扭 力為 4.75 kg-cm(4.12 in-lbs)。 只能使用 60°C/75°C 的銅導線 。 <1.5mm 各部元件介紹 CANopen 通訊連接器 Baud Rate PIN6 PIN7 PIN8 Baud Rate OFF OFF OFF 10kbps OFF OFF ON 250kbps ON OFF OFF 20kbps ON OFF ON 500kbps 接腳 與 CANopen 傳送線連 接。可使用 IFD9503 隨機附帶的 連 接器或者 市 售的連接 器 進行配線 。 信號 敍述 OFF ON OFF 50kbps OFF ON ON 800kbps 1 V- 0VDC ON ON OFF 125kbps ON ON ON 1Mbps 2 CAN_L Signal- 3 SHIELD 遮蔽線 4 CAN_H Signal+ 5 V+ 24VDC Note: The changed setting of the baud rate of CANopen is only valid when IFD9503 is re-powered. When IFD9503 is operating, changing the baud rate will be invalid 1 2 3 4 5 6 7 8 k l CANopen 連接器 f Selecting IFD9503 Communication Mode ERROR indicator CANopen Connector CAN Note: The changed setting of the DIP switch is only valid when IFD9503 is re-powered. When IFD9503 is operating, changing the setting of the DIP switch will be invalid. RUN indicator Specifications Transmission method If the equipment connected to IFD9503 is a Delta servo drive, you only need to switch PIN3 of the DIP switch to “ON”, PIN1 and PIN2 to “OFF” and re-power IFD9503. SCAN indicator CANopen connector 支援的功能與服務 4 4 Equipment PIN1 OFF 1 N.C. 6 7 f Selecting the Equipment Connected to IFD9503 f CANopen DS301 V4.02 f Service Data Object (SDO) DATA- 789 345 H 16 6 f CAN2.0A protocol Product Profile & Outline TXD 3 LED Status Equipment N.C. 3 2 Function Switch Thank you for choosing Delta IFD9503 CANopen slave station communication module. IFD9503 can be applied to the connection between CANopen network and Delta’s programmable logic controller, AC motor drive, servo drive, temperature controller and human machine interface. In addition, the customized and one-to-many functions of IFD9503 allow the customized devices with MODBUS protocol to be connected to the CANopen network. The one-to-many function allows max. 15 MODBUS protocol compliant devices to be connected to the CANopen network. RS-485 N.C. RXD 謝謝您使 用 台達 IFD9503 模組,IFD9503 定義爲 CANopen 從站通訊 模組,用於 將台達可 程 式控制器、台達變頻 器、台達 伺 服驅動器 、 台達溫控 器 以及台達 人 機介面接入 CANopen 網路;此 外 ,IFD9503 還提供自 定 義功能和 一對多功 能 ,自定義 功 能用於將 符 合 MODBUS 協定 的自 定義設備 接 入 CANopen 網路, 一 對多功能 用 於將最多 15 個符合 MODBUS 協 定的設備 接 入 CANopen 網路。 RUN LED Address Switch The two rotary address setup switches set up the node addresses on the CANopen network in hexadecimal form. BCD DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all the wiring again before switching on the power and DO NOT touch any terminal when the power is switched on. Make sure the ground terminal is correctly grounded in order to prevent electromagnetic interference. Signal- SHIELD 4 Address Setting RS-232 2 A Please read this instruction sheet carefully before use and follow the sheet to operate IFD9503 in order to prevent damages on the device or injuries to staff. CAN_L 3 BCD IFD9503 is used for controlling the operating machine and equipment. In order not to damage it, only qualified professional staff familiar with the structure and operation of IFD9503 can install, operate, wire and repair it. 2 A IFD9503 is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may occur. 產品簡介 ERROR LED 0 12 EF ENGLISH 0VDC 交流輸入電源不可連接於輸入∕输出信號端,否則可能造成嚴重損壞,請在上電之前再次確認電源配綫。請勿 務必 正確的接地, 可提 高産 品抗幹擾能力 。 在上 電時觸摸任何 端子 。本 體上的接地端 子 1 012 EF Warning This instruction only provides introductory information on electrical specifications, functions, wiring, trouble-shooting and peripherals for IFD9503. Details of CANopen protocol are not included in this sheet. For more information on CANopen protocol, please refer to relevant reference or literatures. Description V- N.C. 5 OFF To connector with CANopen, use the connector enclosed with IFD9503 or any connectors you can buy in the store for wiring. Signal N.C. 6 LED Indicators & Troubleshooting LED Status CANopen Connector 1 5 請務 必仔細閱讀本使用手 册,幷依照 本手册 指示進 行操作,以免造成産 品受損,或 導致人 員受傷 。 Note: PORT 2 supports RS-232 and RS-485 communication mode only. Components PIN DATA+ 7 DB9 male Use 28-12AWG (1.5mm) single or multiple core wire on I/O wiring terminals. See the figure for its specification. The terminal screws shall be tightened to 4.75 kg-cm (4.12 in-lbs). Use 60°C /75°C copper wires only. 28-12AWG DATA- 4 Terminal No. RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 1,000MHz, 10V/m Certificates 本産品 用來控制運轉中的機械及設備。爲了避免損 壞本産品,只有合格幷 且熟悉本産 品的結構 及操作的專 業人 員才 可以安裝、操 作、 配綫 及維護本産品 。 GND 3 f PORT 2 International Standards: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27 (TEST Ea) Interference immunity 本機爲開 放型 (OPEN TYPE) 機殼,因 此 使用者使 用 本機時, 必 須將的安 裝 於具防塵 、 防潮及免 於 電 擊 ∕衝 擊意外 的外殼配線 箱內。另必須具備保 護措施(如:特殊的工 具或鑰匙才 可打開)防 止非維護人員操作或意外 衝擊本 體, 造成危 險及損壞。 Note: PORT 1 supports RS-485 communication mode only. Operation: 0°C ~ 55°C (temperature), 5 ~ 95% (humidity); pollution degree 2 Shock/vibration immunity Description 1 PORT1 IEC 61131-2, UL508 Storage/operation 本使用說明書僅提供電氣規格、功能規格、安裝配綫、故障排除及周邊裝置部份說明,該手册僅作爲 IFD9503 操作 指南和入門 參考,CANopen 協定的詳細內容這 裏不作 介紹。若想 要瞭解 更多關 於 CANopen 協 定的內 容, 請參閱 相關專業 文章或 書籍 資 料。 Terminal No. 6 5 4 3 2 1 繁體中文 PORT1 f PORT 1 Electrical Specifications Standards 注意事項 PORT2 The communication ports on IFD9503 are used for the connection with other equipments (Delta PLC, AC motor drive, temperature controller, servo drive, HMI and custom equipments). 1 2 3 4 5 LED 燈狀態 位址設定開關 1 H 16 345 345 012 EF F0 1 2 說明 01 ~ 7F 有效的 CANopen 通訊地 址 00, 80 ~ FF 無效的 CANopen 通訊地 址 BUS OFF( 總線脫離 ) 1. 檢查匯流 排 連接是否 正 常 2. IFD9503 重新上電 注意:位址設定開關的設定值變化後,只有等 IFD9503 重新上電啓動後才會生效,當 IFD9503 運行時,變更地址設定值 是無效的。 SCAN LED 燈顯示說明 LED 燈狀態 顯示說明 無電源 檢查 IFD9503 電源並 確認連接 正 常 綠燈閃爍 未檢測到 正 確的下位 設 備資訊 重新連接 IFD9503 與下 位設備 綠燈亮 與下位設 備 通訊正常 紅燈閃爍 功能設定開關(DIP) 紅燈亮 CRC 校 驗錯 誤 IFD9503 連接的 MODBUS 設備部分 斷 線(IFD9503 為 一對多模 式 時) 2. 1. 檢查 IFD9503 與下位設 備之間的 通 訊綫是否 符 合 規格 厂商 ID 477(台达 电子) PORT 1 示 意图 电压规格 11 ~ 25VDC 电流规格 28mA( 典 型值),125mA 冲击电 流 (24VDC) IEC 61131-2,UL508 标准 操作∕储 存环境 2. 檢查 IFD9503 和下位設 備之間連 接 是否正確 3. 重新連線 並 確認通訊 線 符合規格 。 下位設備 接腳 1 接腳 2 ON 接腳 3 OFF 變頻器 OFF ON OFF 可程式控 制 器 OFF ON ON 自定義設 備 ON ON OFF 溫控器 OFF OFF OFF OFF ON 多個 MODBUS 設備 OFF OFF ON 伺服驅動 器 ON ON ON 系統內部 使 用 OFF ON ON RS-485 ON OFF 錯誤設置 RS-232 OFF ON 錯誤設置 通訊速率 接腳 6 接腳 7 接腳 8 OFF OFF 10kbps OFF OFF ON 250kbps ON OFF OFF 20kbps ON OFF ON 500kbps OFF ON OFF 50kbps OFF ON ON 800kbps DB9 male 输出∕入 配线端请 使 用 28-12AWG(1.5mm)单蕊祼线 或 多蕊线,端 子规格 如左所示 。 ON ON OFF 125kbps ON ON ON 1Mbps 与 CANopen 传送线连 接。可使用 IFD9503 随机附带的 连 接器或者 市 售的连接 器 进行配线 。 IFD9503 通訊埠 ڦຍְี! IFD9503 的通訊 埠用於 與下位設 備(台達可程 式控制器、台達變頻 器 、台達溫 控器、台 達 伺服驅動 器 、台達人 機 介面、自 定 義設備) 的 連接。 PORT2 N.C. 2 GND 3 DATA- 4 DATA+ 5 N.C. 6 N.C. 本产 品用 来控 制运转中的机 械及 设备。为 了避免损 坏本 产品,只有 合格幷且熟悉本 产品的结构及操作的专业 人 员才 可以安 装、操 作、配线及 维护 本产 品。 请务 必仔 细阅读 本使 用手 册,幷依照本 手册指示进 行操 作,以 免造 成产 品受损,或导 致人 员受 伤。 交流 输入 电源 不可连接于输 入∕ 输出 信号端,否则 可能造成 严重损 坏,请在上 电之前再次 确认电源配线。请 勿 务必 正 确的 接地,可提 高产 品 抗干 扰能 力。 在上 电时触 摸任 何端子。本体上的 接地端 子 f 通訊埠 PORT 2 PORT 2 示 意圖 端子 No. 1 6 2 7 3 8 4 9 5 DB9 male RS-232 RS-485 1 N.C. N.C. 2 RXD N.C. 3 TXD DATA- 4 N.C. N.C. 5 GND N.C. 6 N.C. N.C. 7 N.C. N.C. 8 N.C. DATA+ 9 N.C. N.C. 谢谢您使 用 台达 IFD9503 模块,IFD9503 定义为 CANopen 从站通讯 模块,用于 将台达可 编 程控器、台 达变频器 、 台达伺服 驱 动器、台 达 温控器以 及 台达人机 界 面接入 CANopen 网络; 此外,IFD9503 还提供 自定义功 能 和一对 多功能,自 定义功能 用 于将符合 MODBUS 协 议的自定 义 设备接入 CANopen 网 络,一对多 功能用于 将 最多 15 个 符合 MODBUS 协议的 设备接入 CANopen 网 络。 ͚۞Αਕڇચ f CAN2.0A 协议 f CANopen DS301 V4.02 f 处理数据 对象 (PDO) f 网络管理 对象 (NMT) f 服务数据 对象 (SDO) யݡγ៍̈́Чొ̬ LED 燈指示說明及故障排除 1 5 RUN LED 燈顯示說明 LED 燈狀態 顯示說明 無電源 檢查 IFD9503 電源並 確認連接 正 常 綠燈單閃 停止 無需處理 綠燈閃爍 預運行 無需處理 綠燈亮 運行 無需處理 節點地址 設 置錯誤 3 4 8 10 Αਕఢॾ! 設置 IFD9503 的節點地 址在 1 ~ 127 之間 顯示說明 9 尺寸单位: mm ERROR LED 燈顯示說明 LED 燈狀態 2 6 7 處理方法 燈滅 處理方法 屏蔽线 CAN_H Signal+ 5 V+ 24VDC 3 4 5 地址设定 说明 6 789 1 H16 01 ~ 7F 有效的 CANopen 通讯地 址 00, 80 ~ FF 无效的 CANopen 通讯地 址 6 789 CANopen ాତጡ 传输方式 CAN 电气隔离 500VDC 燈滅 無錯誤 IFD9503 運行正常 接头 可插拔式 连 接器 (5.08mm) 紅燈單閃 匯流排錯 誤 超出警戒 水 準 檢查網路 連 接及運行 環 境正常 传输电缆 2 条通讯线 、2 条电源 线和 1 条屏 蔽线 1 2 3 4 5 6 7 8 k l 通讯口 f IFD9503 ాତన౯۞Ᏼፄ! 接脚 1 接脚 2 ON OFF OFF 变频器 ON OFF ON 人机介面 OFF ON OFF 可编程控 制 器 OFF ON 接脚 3 ON 自定义设 备 ON ON OFF 温控器 OFF OFF OFF 多个 MODBUS 设备 OFF OFF ON 伺服驱动 器 ON ON ON 系统内部 使 用 下位设备 注意:IFD9503 的功能设定开关设定值变化后,只有等 IFD9503 重新上电启动后才会生效,当 IFD9503 运行时,改变 IFD9503 的功能设定开关设定值是无效的。 f IFD9503 ఼ੈሀё۞Ᏼፄ! RUN 指 示灯 ERROR 指 示灯 CANopen 通讯连接 器 DIN 轨槽 DIN 轨固定 扣 接脚 4 接脚 5 通讯模式 接脚 4 接脚 5 通讯模式 OFF OFF RS-485 ON OFF 错误设置 ON ON RS-232 OFF ON 错误设置 注意:通讯模式的设定值变化后,只有等 IFD9503 重新上电启动后才会生效,当 IFD9503 运行时,变更通讯模式的设定 值是无效的。 f ఼ੈిத۞న!ؠ 接脚 6 接脚 7 接脚 8 显示说明 处理方法 检查 IFD9503 电源并 确认连接 正 常 绿灯闪烁 预运行 无需处理 绿灯亮 运行 无需处理 红灯亮 节点地址 设 置错误 设置 IFD9503 的节点地 址在 1 ~ 127 之间 显示说明 通讯速率 接脚 6 接脚 7 接脚 8 通讯速率 OFF OFF OFF 10kbps OFF OFF ON 250kbps ON OFF OFF 20kbps ON OFF ON 500kbps OFF ON OFF 50kbps OFF ON ON 800kbps ON ON OFF 125kbps ON ON ON 1Mbps 处理方法 灯灭 无错误 IFD9503 运行正常 红灯单闪 总线错误 超 出警戒水 平 检查网络 连 接及运行 环 境正常 显示说明 发生错误 控 制事件 处理方法 检查 IFD9503 与主站之 间的通讯 线 连接是否 正 常 BUS OFF(总线脱离) 注意:CANopen 通讯速率的设定值变化后,只有等 IFD9503 重新上电启动后才会生效,当 IFD9503 运行时,变更通迅 速率的设定值是无效的。 1. 检查总线 连 接是否正 常 2. IFD9503 重新上电 SCAN LED ፶ពϯᄲ!ځ LED 灯状态 显示说明 处理方法 灯灭 无电源 检查 IFD9503 电源并 确认连接 正 常 绿灯闪烁 未检测到 正 确的下位 设 备信息 重新连接 IFD9503 与下 位设备 绿灯亮 与下位设 备 通讯正常 红灯闪烁 红灯亮 功能设定 开 关 (DIP) SCAN 指示 灯 N.C. 1. CRC 校 验错 误 2. IFD9503 连接的 MODBUS 设备部分 掉 线 (IFD9503 为一对多 模 式时) 1. 通讯连接 失 败或无法 连 接。 地址设定 开 关 功能设定 开 关说明 N.C. 无需处理 红灯亮 功能设定 开 关用于设置 IFD9503 所连接的下 位 设备类型 、 通讯口的 选 择以及 IFD9503 与 CANopen 主站通讯 速 率的设定 。 下位设备 9 N.C. 0 注意:地址设定开关的设定值变化后,只有等 IFD9503 重新上电启动后才会生效,当 IFD9503 运行时,变更地址设定值 是无效的。 接脚 3 DATA+ 无电源 红灯双闪 H16 范例:用户 需要将 IFD9503 的节点 地址设置为 26 (H1A),只需要将×161 对应的旋 转开关旋 转 到”1”位置,将×16 0 对应的旋 转 开关旋转 到”A”位置即 可 。 接脚 2 N.C. N.C. 停止 LED 灯状态 !гӬనؠฟᙯ! 两个旋转 式 地址设定 开 关以 16 进 制形式设定 CANopen 网络上的 节 点地址。 设定范围 :01 ~ 7F(00 和 80 ~ FF 不可用 )。 接脚 1 N.C. 8 绿灯单闪 LED 灯状态 1 2 范例:IFD9503 连接的 下位设备 为 伺服驱动 器 ,只需 将功 能设定开 关 的接脚 3 拨 至 ON 位置 ,接脚 1 与 接脚 2 的 位置拨至 OFF 位置,重 新上电即 可 。 注意:該通訊埠僅支援 RS-232 通訊方式和 RS-485 通訊模式,不支援其他通訊模式。 IFD9503 有三個 LED 指 示燈,RUN LED、ERROR LED 和 SCAN LED,用來顯示 IFD9503 的通訊連接 狀 態。 SHIELD 4 7 灯灭 Αਕనؠฟᙯ(DIP) யݡᖎ̬ 注意:該通訊埠只支援 RS-485 通訊模式,不支援其他通訊模式 3 N.C. N.C. ERROR LED ፶ពϯᄲ!ځ BCD PORT1 說明 1 Signal- N.C. GND 6 LED ፶ϯᄲ߇̈́ځᅪଵੵ! A 6 5 4 3 2 1 端子 No. 0VDC CAN_L BCD 本机为开 放型 (OPEN TYPE) 机壳,因此 使用者使 用 本机时,必 须将的安 装 于具防尘、防潮及免 于 电 击 ∕冲 击意 外的外 壳配 线箱内。另必 须具 备保 护 措施(如:特殊 的工 具 或钥 匙才可 打开)防止 非维 护人 员 操作或意外 冲击本 体,造成 危 险及 损坏。 V- 2 A 本使 用说明书仅提供 电气规 格、功能规 格、安装配 线、故障排 除及 周边装 置部份说明,该手册仅作为 IFD9503 操作指 南和 入门 参考,CANopen 协议的 详细 内容这 里不作介绍。若 想要 了解更多关于 CANopen 协 议的内容 , 请参阅 相关专业 文章或 书籍 资 料。 f 通訊埠 PORT 1 PORT 1 示 意圖 简体中文 PORT1 叙述 1 N.C. 5 IFD9503 有三个 LED 指 示灯,RUN LED、ERROR LED 和 SCAN LED,用来显示 IFD9503 的通讯连接 状 态。 LED 灯状态 信号 4 RUN LED ፶ពϯᄲ!ځ 只能使用 60°C/75°C 的铜导线 。 接脚 N.C. 注意:该通讯口仅支持 RS-232 通讯方式和 RS-485 通讯模式,不支持其它通讯模式。 ЧొІ̬! 注意:CANopen 通訊速率的設定值變化後,只有等 IFD9503 重新上電啓動後才會生效,當 IFD9503 運行時,變更通迅 速率的設定值是無效的。 紅燈亮 N.C. IFD9503 端子螺丝 扭 力为 4.75 kg-cm(4.12 in-lbs)。 通訊速率 OFF RS-485 DATA- 1 6 2 7 3 8 4 9 5 CANopen ఼ੈాତጡ! 接腳 6 接腳 7 接腳 8 RS-232 端子 No. TXD <1.5mm f 通訊速率的設定 N.C. 3 通訊模式 注意:通訊模式的設定值變化後,只有等 IFD9503 重新上電啓動後才會生效,當 IFD9503 運行時,變更通訊模式的設定 值是無效的。 N.C. 6 N.C. 345 OFF 接腳 5 DATA+ 5 RXD 28-12AWG 接腳 4 通訊模式 DATA- 4 2 012 EF 接腳 5 3 1 在配线 时 请勿将输 入 点信号线 与 输出点或 电 源等动力 线 置于同一 线糟内。 f IFD9503 通訊模式的選擇 接腳 4 PORT 2 示 意图 IFD9503 在安装时 , 请装配于 封 闭式之控 制 箱内,其 周 围应保持 一定之空 间 (如右图 所 示), 以确 保 IFD9503 散热功能 正 常。 注意:IFD9503 的功能設定開關設定值變化後,只有等 IFD9503 重新上電啓動後才會生效,當 IFD9503 運行時,改變 IFD9503 的功能設定開關設定值是無效的。 GND EFT (IEC 61131-2, IEC 61000-4-4): Analog & Communication I/O: 1KV ሹ̰щ྅̈́੨ቢ! 範例:I IFD9503 連接的 下位設備 爲 伺服驅動 器 ,只需將 功 能設定開 關 的接腳 3 撥 至 ON 位 置 ,接腳 1 與 接腳 2 的位置撥至 OFF 位置, 重新上電 即 可。 N.C. 2 RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 1000MHz, 10V/m CE 认证、UL 认证 认证项目 人機介面 说明 1 f!఼ੈ˾ PORT 2 ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge 下位設備 PORT1 注意:该通讯口只支持 RS-485 通讯模式,不支持其它通讯模式 操作:0°C ~ 55°C(温 度),5 ~ 95%(湿度 ),污 染等级 2 国际标准 规 范 IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27 (TEST Ea) 耐振动∕冲 击 噪声免疫 力 接腳 3 PORT1 储存:-25°C ~ 70°C(温 度),5 ~ 95%(湿度) 1. 檢查下位 設 備通訊格 式 是否正確 IFD9503 連接的 MODBUS 設備全部 斷 線(IFD9503 為 一對多模 式 時) 端子 No. 6 5 4 3 2 1 ᒖဩఢॾ 标准 PORT2 f ఼ੈ˾ PORT 1 345 OFF 0 (Non-Profile) F0 1 2 ON 设备类型 IFD9503 的通讯口用 于 与下位设 备(台达可 编 程控器、台 达变频器 、台达温控 器、台达 伺 服驱动器 、 台达人机 介 面、自定 义 设备)的 连 接。 E 接腳 2 支持 10k、20k、50k、125k、250k、500k、800k、1M bps(位∕秒 ) 2. 檢查附近 是 否有電磁 干 擾 f IFD9503 連接設備的選擇 接腳 1 PDO、SDO、SYNC( 同步对象 )、Emergency(紧急对 象)、NMT 串行传输 速 率 無需處理 1. 2. 1. 通訊連接 失 敗或無法 連 接 功能設定 開 關用於設置 IFD9503 所連接的下 位 設備類型、通訊口的 選 擇 以及 IFD9503 與 CANopen 主站通訊 速率的設 定 。 信息类型 ঈఢॾ! 處理方法 燈滅 IFD9503 ఼ੈ˾! ఼ੈ 處理方法 檢查 IFD9503 與主站之 間的通訊 線 連接是否 正 常 發生錯誤 控 制事件 紅燈亮 BCD BCD 範例:用戶需要將 IFD9503 的節點 地址設置爲 26 (H1A), 只需要將×161 對應的旋 轉開關旋 轉 到”1”位置,將×16 0 對應的旋 轉 開關旋轉 到”A”位置即 可 。 地址設定 顯示說明 紅燈雙閃 0 789 A 6 A 6 設定範圍 :01 ~ 7F(00 和 80 ~ FF 不可用 )。 789 E H 16 兩個旋轉 式 位址設定 開 關以 16 位元形式設定 CANopen 網路上的節 點 地址。 2. IFD9503 连接的 MODBUS 设备全部 掉 线(IFD9503 为 一对多模 式 时) 无需处理 1. 检查 IFD9503 与下位设 备之间的 通 讯线是否 符 合规格 2. 检查附近 是 否有电磁 干 扰 1. 检查下位 设 备通讯格 式 是否正确 2. 检查 IFD9503 和下位 设备之间 连 接是否正 确 3. 重新连线 幷 确认通讯 线 符合规格