Download Lightolier Skyway SKS2GPK2FT User's Manual
Transcript
Skyway SKS2GPK2FT 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp Twin Tube T5 Page 1 of 2 Features • • • • • • • • • • • • • • • • • Aesthetically pleasing triple lens design. Curved high light transmission frost white acrylic side lenses. Clear acrylic conical prismatic center lens. Internal reflector coated with 95% reflective white paint. 89.9% efficient (2 Lamp 25 watt TT5) 76.5% efficient (2 Lamp 40 watt TT5) 5" deep body. Black housing exterior for cooler ballast operating temperature. Eyeleted heat removal vents in fixture ends. Hemmed over side rails for maximum safety. Fixture ends turned-in for safe handling. Built-in earthquake clips (patent no. 5,072,344). Door jamb finished black on four sides for positive light stop. True mitered corner aluminum lens frame. Spring loaded rooster head latches. 18 gauge steel hinges. Construction to meet NYC Code Requirements or Chicago Plenum is available. Mounting Methods Dimensions 24" (610mm) 5" (127mm) 2" max. 24" G 2" max. 15/16" or 9/16" Exposed T-grid ceiling. 24" T 15/16" or 9/16" Air supply slots (SKA Only) Exposed Slot T-grid ceiling Skyway Fixture Support (by others) 23-7/8" (606mm) Drywall Kit (See Options) Drywall (by others) 2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s earthquake clip installed (lay-in grid) 15-11/16" (398mm) Drywall Kit, Catalog Number: FK92X2. 5" (127mm) Job Information Type: Job Name: Cat. No.: Lamp(s): Volts/Ballast: 01/09 For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 a Philips Group Section 5/Folio MA12-10 Lightolier is a Philips group brand Skyway SKS2GPK2FT 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp Twin Tube T5 Page 2 of 2 Model No. SKS2GPK2FTUNVIB (25 watt lamp) Model No. SKS2GPK2FTUNVIB (40 watt lamp) LER = FP - 64.0 IW - 59.4 BF - 0.92 Comparative yearly lighting energy cost per 1000 lumens = $3.75 LER = FP - 64.3 IW - 69.1 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $3.73 Report Number: G2008207 Catalog Number: SKS2GPK2FTUNVIB Lamps: (2) PL-L40/835/XEW/4P/RS/IS 25W Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly. Ballast: ICN-2TTP40-SC Report is based on 2300 Lumens per lamp. Efficiency: 89.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600 COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200 RC 80 50 30 RW 70 50 30 50 30 10 50 30 01 99 95 91 89 87 84 86 84 02 91 84 78 79 75 71 76 73 03 83 75 68 71 65 61 68 64 04 77 67 59 63 57 53 61 56 05 71 60 52 57 51 46 55 50 06 66 54 47 52 45 41 50 45 07 61 49 42 47 41 36 46 40 08 57 45 38 43 37 33 42 37 09 53 42 35 40 34 30 39 33 10 50 38 32 37 31 27 36 31 CANDELA DISTRIBUTION 0.0 45.0 90.0 0 1721 1721 1721 FLUX 5 1704 1705 1709 162 15 1613 1631 1658 462 25 1449 1520 1614 704 35 1229 1390 1548 863 45 921 1012 1025 773 55 595 653 623 569 65 337 367 348 364 75 171 176 161 188 85 32 45 25 46 90 0 0 0 Report Number: G2008206 Catalog Number: SKS2GPK2FTUNVIB Lamps: (2) PL-L40/835/RS/IS Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly. Ballast: ICN-2TTP40-SC Report is based on 3300 Lumens per lamp. Efficiency: 76.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600 COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200 RC 80 50 30 RW 70 50 30 50 30 10 50 30 01 84 81 78 76 74 72 73 71 02 77 71 66 67 63 60 65 62 03 71 63 57 60 55 51 58 54 04 65 56 50 54 48 44 52 47 05 60 51 44 48 43 39 47 42 06 56 46 39 44 38 34 43 38 07 52 42 35 40 35 31 39 34 08 48 38 32 37 31 27 36 31 09 45 35 29 34 29 25 33 28 10 42 33 27 31 26 23 31 26 ZONAL LUMEN SUMMARY ZONE 00-030 00-040 00-060 00-090 90-180 00-180 10 82 69 60 52 46 40 36 32 29 27 LUMENS % LAMP 1328 28.9 2191 47.6 3537 76.9 4134 89.9 0000 0.0 4134 89.9 CANDELA DISTRIBUTION % FIXT 32.1 53.0 85.5 100.0 000.0 100.0 LUMINANCE DATA IN CANDELA/SQ. METER AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4326. 4753. 4814. 55 3445. 3781. 3607. 65 2648. 2884. 2735. 75 2194. 2258. 2066. 85 1219. 1715. 953. 0.0 45.0 90.0 0 2055 2055 2055 FLUX 5 2040 2040 2043 194 15 1937 1957 1986 554 25 1747 1826 1932 846 35 1482 1672 1859 1041 45 1131 1248 1276 956 55 736 808 772 703 65 420 459 435 454 75 218 222 207 240 85 48 66 40 65 90 0 0 0 ZONAL LUMEN SUMMARY ZONE 00-030 00-040 00-060 00-090 90-180 00-180 10 69 59 51 44 38 34 30 27 25 22 LUMENS % LAMP 1593 24.1 2635 39.9 4294 65.1 5052 76.5 0000 0.0 5052 76.5 % FIXT 31.5 52.2 85.0 100.0 000.0 100.0 LUMINANCE DATA IN CANDELA/SQ. METER AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 5312. 5861. 5993. 55 4261. 4678. 4470. 65 3300. 3607. 3418. 75 2797. 2849. 2656. 85 1829. 2515. 1524. Ordering Information Explanation of Catalog Number. Example: SKS2GPK2FTUNVIB 2 Skyway Recessed Fluorescent Body Style: S = Static A = Air Fixture Width SK Standard Skyway SY For NYC Code – I.B.E.W. Manufactured NK For NYC Code – Local 3 Manufactured Ceiling Type: G = Standard Grid T = Slot Grid P K 2 FT Side Lens: P= Frost White Acrylic Lens Center Lens: K= Pattern 19 .156 Virgin Acyrlic Lens Lamp Quantity 2=2 Lamp Lamp: (By Others) FT = Twin Tube T5 Voltage: 120, 277 or UNV=120-277 Ballast Type: < 20THD < 10THD 2 Lamp Elec. TT5 SB* IB** (25 or 40 Watt) 2 Lamp Elec. TT5 – PR† (40 Watt) 2 Lamp Elec. TT5 BE* – (50 Watt) 2 Lamp Elec. TT5 – BF* (55 Watt) LOL Dimming TT5 PB – *Instant Start Standard. Other dimming options. Consult factory. NOTE: For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A. Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30. Specifications Performance: In an installation of 2 lamp 25W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .95. To reduce glare the average brightness at 65° shall not exceed 2648 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.9%. Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated. Lightolier is a Philips group brand Options: Add appropriate suffix to catalog no., ie: (A) Specifications (continuned) Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org Job Information Type: For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 a Philips Group Section 5/Folio MA12-10