Download Lightolier MBS2GHP1FT User's Manual
Transcript
Mini-Beam HP 2' x 2' Recessed Fluorescent Page 1 of 2 MBS2GHP224 or 1FT Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt, 1 Lamp TT5 Features • Direct/indirect lamp shield appearance with soft contoured interior. • Four inch wide with white acrylic lens. • 85.3% efficient (2 lamp 24W). • 83.3% efficient (1 lamp 40W). • 1.4 spacing mounting ratio (2 lamp 24W). • 1.5 spacing mounting ratio (1 lamp 40W). • Only 5-1/2" deep. • Same fixture fits both G and T ceiling types. • Fits flush to face of slot grid (T) ceiling types. • Lamp shield hinges from either side. • Hinged external ballast housing compartment. • Can be continuous row mounted. • Wiring access plate standard. • 4 hold-down clips standard. • Housing is 20 gauge steel, meets NYC Code requirements. • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices. Mounting Methods Dimensions Hinged external ballast housing compartment Exposed T-bar by others 1-1/2" max. 1-7/8" max. Acoustical material by others exposed t-grid ceiling 4" (102mm) 24" (610mm) Acoustical material by others 15/16" 24" 5-1/2" (139mm) Exposed T-bar by others 9/16" 24" 3-1/2" (89mm) 2" x 2-1/2" access plate with (2) 7/8" dia. K.O.s exposed slot t-grid ceiling Features Hinged external ballast housing compartment Ballast hold-down clips hinged external ballast housing compartment 24" (610mm) Job Information Type: Job Name: Cat. No.: Lamp(s): Volts/Ballast: 2/06 Lightolier a Genlyte company www.lightolier.com Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M20-28 Mini-Beam HP 2' x 2' Recessed Fluorescent Page 2 of 2 MBS2GHP224 or 1FT Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt, 1 Lamp TT5 Model No. MBS2GHP224UNVPG Model No. MBS2GHP1FT120SB LER = FP -64.4 IW - 52.8 BF - 1.00 Comparative yearly lighting energy cost per 1000 lumens = $3.73 LER = FP - 68.5 IW - 39.7 BF - 1.0 Comparative yearly lighting energy cost per 1000 lumens = $3.64 Report Number: G2005301 Catalog Number: MBS2GHP224UNVPG Lamps: FP24/835 HO Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic lens Ballast: Triad B224PUNV-D Report is based on 2000 Lumens per lamp. Efficiency: 85.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920 COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200 RC 80 50 30 RW 70 50 30 50 30 10 50 30 01 92 88 84 82 80 77 79 77 02 84 76 70 72 67 63 69 65 03 76 67 59 63 57 52 60 55 04 69 59 51 55 49 44 53 48 05 64 52 44 49 43 38 48 42 06 59 47 39 45 38 33 43 37 07 54 42 35 40 34 29 39 33 08 50 39 31 37 30 26 36 30 09 47 35 28 34 28 23 33 27 10 44 34 26 31 25 21 30 25 CANDELA DISTRIBUTION0 0.0 45.0 90.0 0 1021 1021 1021 FLUX 5 1015 1030 1045 99 15 979 1035 1099 296 25 911 1030 1062 465 35 814 939 949 571 45 687 800 873 613 55 532 637 713 566 65 348 449 520 439 75 169 285 355 286 85 31 79 94 79 90 0 0 0 COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200 RC 80 50 30 RW 70 50 30 50 30 10 50 30 01 90 86 82 80 78 75 77 75 02 82 74 68 70 65 61 67 63 03 74 65 58 61 55 51 59 54 04 68 57 50 54 48 43 52 47 05 62 51 43 48 42 37 46 41 06 57 46 38 43 37 32 42 36 07 53 41 34 39 33 28 38 32 08 49 38 30 36 30 25 35 29 09 46 34 27 33 27 22 32 26 10 43 32 25 30 24 20 30 24 10 74 61 51 43 37 33 29 26 23 21 LUMINANCE DATA IN CANDELA/SQ. METER AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2866. 3337. 3641. 55 2736. 3276. 3666. 65 2429. 3134. 3629. 75 1926. 3248. 4046. 85 1049. 2673. 3131. Report Number: G2005303 Catalog Number: MBS2GHP1FT120SB Lamps: 40W TT5 Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic lens Ballast: RCN-1TTP40-SC Report is based on 3150 Lumens per lamp. Efficiency: 83.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.5 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800 ZONAL LUMEN SUMMARY ZONE 00-030 00-040 00-060 00-090 90-180 00-180 LUMENS % LAMP 860 21.5 1431 35.8 2610 65.2 3413 85.3 0000 0.0 3413 85.3 0.0 45.0 90.0 0 778 778 778 FLUX 5 774 780 788 75 15 745 793 828 223 25 689 777 811 352 35 610 720 754 440 45 513 632 684 476 55 399 501 543 437 65 270 350 395 339 75 136 219 268 220 85 28 64 80 64 90 2 2 2 10 73 60 50 42 36 32 28 25 22 20 LUMINANCE DATA IN CANDELA/SQ. METER % FIXT 25.2 41.9 76.5 100.0 000.0 100.0 CANDELA DISTRIBUTION0 AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2162. 2664. 2883. 55 2073. 2603. 2822. 65 1904. 2468. 2786. 75 1566. 2522. 3086. 85 958. 2189. 2736. ZONAL LUMEN SUMMARY ZONE 00-030 00-040 00-060 00-090 90-180 00-180 LUMENS % LAMP 650 20.6 1090 34.6 2002 63.6 2625 83.3 0000 00.0 2625 83.3 % FIXT 24.8 41.5 76.3 100.0 000.0 100.0 Ordering Information Explanation of Catalog Number. Example: MBS2GHP224UNVPG Mini-Beam Direct/Indirect Recessed S 2 G HP Body Style: S = Static Fixture Width Ceiling Type: Fits both Standard Grid and Slot Grid High Performance Prismatic Lens MB Standard Mini-Beam M3 For NYC Code –Local 3 Manufactured Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF. Electrical/Wiring Options: Consult factory. Lamp Type: Lamp (By others) Quantity: 1 = 1 Lamp FT = Twin Tube T5 2 = 2 Lamp 14 = T5 14 Watt 24 = T5HO 24 Watt (Nominal 24") Options: Add appropriate suffix to catalog no, ie: (GLR) Voltage: 120, 277 or UNV=120-277 Ballast Type: < 20THD 1 Lamp Elec. TT5 SB * (40 Watt) 1 Lamp Elec. TT5 (40 Watt) Program Start 1 Lamp Elec. TT5 BE * (50 Watt) Program Start – 1 Lamp Elec. TT5 (55 Watt) Program Start Linear T5 Elec. Program Start – *Instant Start Standard < 10THD IB *† PR *† BP *† BF *† PG ** NOTE: For 1 lamp TT5 UNV voltage you must use PR, BP or BF Ballast Code. DA = DALI digital addressable dimming Specifications Performance: In an installation of 2 lamp 24W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3629 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.8%. Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–white virgin acrylic lens. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. Job Information Type: Lightolier a Genlyte company www.lightolier.com Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M20-28