INSTRUCTION SHEET
IS:SL110A
04-05/Rev-03
INSTRUCTION FOR INSTALLATION KUBIK LIGHT
LINEAR FLUORESCENT LUMINAIRE
A. POWER SUPPLY:
1. Follow the instructions sheet on the appropriate power
supply. (See series ISSL003)
BLANK EXTENSION
B. COVER: (if required)
1. Carefully pull the lamp holder housing out from the
channel. (Fig.1)
2. Insert the end of a small slot screwdriver into the slot.
(Fig.2)
3. Lift the cover gently all along the channel. (Fig.2)
4. Ajust ball plunger pressure as needed. (Fig.4)
To reinstall the cover
1. Align one end of the cover with the block in the channel.
(Fig.3)
2. Press the cover along the length of channel. (Fig.3)
C. DIRECTION:
1. Follow the instructions Sheet No. ISSL003H.
CHANNEL
D. LAMP:
(does not apply to the extended blank model no. SL003F)
2" and 2-3/4" model
1. Carefully pull the lamp holder housing out of the channel.
(Fig.1)
2. Align the pins of the lamp with the lamp holder(s), and
push in until they click. (Fig.5)
13-7/8" model
1. Align the pins of the lamp with the lamp holder, and push
in until they click. (Fig.6)
2. Gently push the stem outward and align the of the lamp
with the lamp holder, and push together until they
click. (Fig.6)
FIG.1
LAMP
HOLDER
COVER
CHANNEL
FIG.2
SLOT
SCREWDRIVER
BALL
LOCK
Linear fluorescent lamp T5 miniature, BI-PIN base
BLOCK
COVER
CHANNEL
FIG.3
FIG.4
LAMP
HOLDER
LAMP
HOLDER
LAMP
PINS
STEM
FIG.5
LAMP HOLDER
PINS
LAMP
FIG.6