Download Goodman Mfg GSX User's Manual

Transcript
TECHNICAL MANU
AL
MANUAL
GSX/VSX 13 SEER Condensing Units
with R-410A
• Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians
only. Goodman does not assume any responsibility for property damage or
personal injury due to improper service procedures or services performed by an
unqualified person.
Copyright © 2007 - 2010 Goodman Manufacturing Company, L.P.
RT6113005r9
August 2010
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
G
S
X
13
024
PRODUCT
FAMILY:
S: Split System
SEER:
SEER Rating
1
A
ELECTRICAL:
1: 208-230v
1ph/60Hz
3: 208-230v
3ph/60Hz
4: 460v
3ph/60Hz
BRAND:
®
G: Goodman Brand
A
MINOR REVISION:
A: Initial Release
MAJOR REVISION:
A: Initial Release
(Standard Feature Set Model)
®
S: Goodman Deluxe
V: Value
PRODUCT TYPE:
C: Condenser R-22
X: Condenser R-410A
H: Heat Pump R-22
Z: Heat Pump R-410A
WARNING
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
Goodman will not be responsible
for any injury or property damage
arising from improper service or
service procedures. If you install or perform service on
this unit, you assume responsibility for any personal
injury or property damage which may result. Many jurisdictions require a license to install or service heating and
air conditioning equipment.
WARNING
2
NOMINAL
CAPACITY
018: 1.5 Tons
024: 2 Tons
030: 2.5 tons
036: 3 Tons
042: 3.5 Tons
048: 4 Tons
060: 5 tons
Installation and repair of this unit
should be performed ONLY by individuals meeting the requirements (at a minimum) of an "entry level technician", as
specified by the Air Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this
unit without such background may result in product
damage, personal injury or death.
WARNING
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
GSX130181A*
GSX130241A*
GSX130301A*
GSX130361A*
GSX130421A*
GSX130481A*
GSX130601A*
GSX130363A*
GSX130483A*
GSX130484A*
GSX130603A*
GSX130604A*
GSX130181B*
GSX130241B*
GSX130301B*
GSX130361B*
GSX130421B*
GSX130481B*
GSX130601B*
VSX130181A*
VSX130241A*
VSX130301A*
VSX130361A*
VSX130421A*
VSX130481A*
VSX130181B*
VSX130601B*
GSX130181C*
* Indicates minor revision & is not used for order entry or inventory management
WARNING
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
that is not design certified by Goodman for use with this unit. Serious
property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the
use of such non-approved devices.
WARNING
To prevent the risk of property
damage, personal injury, or death,
do not store combustible materials or use gasoline or other flammable liquids or vapors
in the vicinity of this appliance.
WARNING
3
PRODUCT DESIGN
GSX/VSX13 models are available in 1 1/2 through 5 ton sizes
and use R-410A refrigerant. They are designed for 208/230
volt single phase applications.
Select GSX13 models are available in 208/230 and 460 volt
3-phase applications. These models use R-410A refrigerant.
The condenser air is pulled through the condenser coil by a
direct drive propeller fan. This condenser air is then discharged out of the top of the cabinet.
These units are designed for free air discharge, so no additional resistance like duct work shall be attached.
The suction and liquid line connections on present models
are of the sweat type for field piping with refrigerant type copper. Front seating valves are factory installed to accept the
field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. GSX/
VSX units are charged for the matching evaporator coil and a
15 foot refrigerant line set.
Systems should be properly sized by heat gain and loss
calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is
the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space.
GSX/VSX models use the Copeland Scroll "Ultratech" Series compressors which are specifically designed for R-410A
refrigerant. There are a number of design characteristics which
are different from the traditional reciprocating and/or scroll
compressors.
WARNING
To avoid possible injury, explosion or death, practice
safe handling of refrigerants.
Special consideration must be given to location of the condensing unit(s) in regard to structures, obstructions, other
units, and any/all other factors that may interfere with air
circulation. Where possible, the top of the unit should be
completely unobstructed; however, if vertical conditions require placement beneath an obstruction there should be a
minimum of 60 inches between the top of the unit and
the obstruction(s). The specified dimensions meet requirements for air circulation only. Consult all appropriate regulatory codes prior to determining final clearances.
Another important consideration in selecting a location for
the unit(s) is the angle to obstructions. Either side adjacent
the valves can be placed toward the structure provided the
side away from the structure maintains minimum service clearance. Corner installations are strongly discouraged.
DO NOT locate the unit:
–
–
Directly under a vent termination for a gas appliance.
Within 3 feet of a clothes dryer vent.
–
Where the refreezing of defrost water would create a
hazard.
–
Where water may rise into the unit.
"Ultratech" Series scroll compressors will not have a discharge thermostat, some of the early model scroll compressors required discharge thermostats.
Due to their design Scroll compressors are inherently more
tolerant of small quantities of liquid refrigerant.
NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued
floodback or flooded start conditions may wash oil from the
bearing surfaces causing premature bearing failure.
NOT
RECOMMENDED
B
Operating pressures and amp draws may differ from standard reciprocating and/or scroll compressors. This information may be found in the "Cooling Performance Data" section.
IMPORTANT NOTE: Because of the potential damage to
compressors, do not allow suction pressure at service valve
to drop below 20 PSIG when pumping unit system down for
repair. Outdoor section, depending on line set length and
amount of charge in system, may not be able to hold the
entire system charge.
4
B
A
"Ultratech" Series scroll compressors use "POE" or
polyolester oil which is NOT compatible with mineral oil based
lubricants like 3GS. "POE" oil must be used if additional oil
is required.
B
AA
C
A
OK!
B
AA
OK!
C
AA
AA
AA
OK!
OK!
OK!
OK!
AA
C
AA
C
Minimum Airflow Clearance
Model Type
A
B
C
Residential
10"
10"
18"
12"
12"
18"
Light Commercial
AA
20"
24"
DIMENSIONS
PRODUCT DESIGN
D
W
H
Model
GSX130181A*
Dimensions - W x D x H
26" x 26" x 32¼"
GSX130241A*
26" x 26" x 32¼"
GSX130301A*
26" x 26" x 32¼"
GSX130361A*
29" x 29" x 32¼
GSX130421A*
29" x 29" x 34¼"
GSX130481A*
29" x 29" x 38¼"
GSX130601A*
35½" x 35½" x 38¼"
GSX130181B*
26" x 26" x 27½"
GSX130241B*
26" x 26" x 27½"
GSX130301B*
GSX130361B*
GSX130363A*
GSX130421B*
26" x 26" x 27½"
VSX130181A*
26" x 26" x 27½"
VSX130241A*
26" x 26" x 27½"
VSX130301A*
26" x 26" x 27½"
VSX130361A*
29" x 29" x 28¾"
VSX130421A*
29" x 29" x 36¼"
VSX130481A*
29" x 29" x 36¼"
VSX130181B*
26" x 26" x 27½"
VSX130601B*
29" x 29" x 40"
29" x 29" x 28¾"
29" x 29" x 36¼"
GSX130481B*
GSX130483A*
GSX130484A*
29" x 29" x 36¼"
GSX130601B*
GSX130603A*
GSX130604A*
29" x 29" x 40"
GSX130181C*
26" x 26" x 27½"
5
CONDENSING UNIT SPECIFICATIONS
GSX130[18-60]1A*
GSX130181A*
GSX130241A*
GSX130301A*
GSX130361A*
18,000
24,000
30,000
36,000
R.L. Amps
9.00
13.4
12.8
16.6
L.R. Amps
48.0
58.3
64.0
79.0
Open
610 PSIG
610 PSIG
610 PSIG
610 PSIG
Close
420 PSIG
420 PSIG
420 PSIG
420 PSIG
Cooling Capacity, BTUH
Compressor
High Pressure Switch
Condenser Fan Motor
Horsepower
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
1/6
1/6
1/6
1/6
1.10
1.10
1.10
1.10
3/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
3/4"
120.0
116.0
129.0
131.0
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
12.3
17.9
17.1
21.9
20
30
30
35
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
178
178
180
197
GSX130421A*
GSX130481A*
GSX130601A*
42,000
48,000
60,000
17.9
112.0
19.8
109.0
26.4
134.0
Open
610 PSIG
610 PSIG
610 PSIG
Close
420 PSIG
420 PSIG
420 PSIG
Refrigerant Charge
Power Supply
(1)
Minimum Circuit Ampacity
Maximum Overcurrent Device
(2)
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
Cooling Capacity, BTUH
Compressor
R.L. Amps
L.R. Amps
High Pressure Switch
Condenser Fan Motor
Horsepower
1/6
1/4
1/4
1.10
1.50
1.50
Liquid Line, Inches O.D.*
3/8"
3/8"
3/8"
Suction Line, Inches O.D.*
7/8"
7/8"
7/8"
151.0
166.0
184.0
208/230-60-1
208/230-60-1
208/230-60-1
23.5
26.3
34.5
40
45
60
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
219
225
240
F.L. Amps
Refrigerant Charge
Power Supply
(1)
Minimum Circuit Ampacity
Maximum Overcurrent Device
Electrical Conduit Size
(2)
Power Supply (Inches)
Approximate Shipping Weight
(1)
(2)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
6
CONDENSING UNIT SPECIFICATIONS
GSX130181B*
GSX130241B*
GSX130301B*
18,000
24,000
30,000
R.L. Amps
9.00
13.5
12.8
L.R. Amps
48.0
58.3
64.0
Cooling Capacity, BTUH
GSX130[18-60]1B*
Compressor
High Pressure Switch
Open
N/A
N/A
N/A
Close
N/A
N/A
N/A
1/6
1/6
1/6
1.10
1.10
1.10
3/8"
3/8"
3/8"
Condenser Fan Motor
Horsepower
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
3/4"
3/4"
3/4"
Refrigerant Charge
72.0
79.0
81.0
208/230-60-1
208/230-60-1
208/230-60-1
12.4
18.0
17.1
20
30
30
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
149
151
152
GSX130361B*
GSX130421B*
GSX130481B*
GSX130601B*
36,000
42,000
48,000
60,000
R.L. Amps
16.7
L.R. Amps
79.0
17.9
112.0
19.9
109.0
25.0
134.0
Power Supply
(1)
Minimum Circuit Ampacity
Maximum Overcurrent Device
(2)
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
Cooling Capacity, BTUH
Compressor
High Pressure Switch
Open
N/A
N/A
N/A
N/A
Close
N/A
N/A
N/A
N/A
Condenser Fan Motor
Horsepower
1/6
1/4
1/4
1/4
1.10
1.50
1.50
1.50
Liquid Line, Inches O.D.*
3/8"
3/8"
3/8"
3/8"
Suction Line, Inches O.D.*
3/4"
7/8"
7/8"
7/8"
Refrigerant Charge
92.0
124.0
128.0
125.0
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
22.0
23.9
26.4
32.8
35
40
45
50
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
159
194
195
200
F.L. Amps
Power Supply
(1)
Minimum Circuit Ampacity
Maximum Overcurrent Device
(2)
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
(1)
(2)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
7
CONDENSING UNIT SPECIFICATIONS
GSX130181C*
GSX130181C*
Cooling Capacity, BTUH
18,000
SEER/EER
13 / 11
Compressor
R.L. Amps
6.70
L.R. Amps
40.0
High Pressure Switch
Open
N/A
Close
N/A
Condenser Fan Motor
Horsepower
1/6
F.L. Amps
1.10
Liquid Line, Inches O.D.*
3/8"
Suction Line, Inches O.D.*
3/4"
Refrigerant Charge
71.0
Power Supply
208/230-60-1
(1)
9.5
Minimum Circuit Ampacity
(2)
Maximum Overcurrent Device
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
(1)
(2)
15
1/2 or 3/4
135
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
8
CONDENSING UNIT SPECIFICATIONS
GSX130[36-60][3,4]* *
GSX130363A* GSX130483A* GSX130484A* GSX130603A* GSX130604A*
Cooling Capacity, BTUH
36,000
48,000
48,000
60,000
60,000
74
76
76
77
77
R.L. Amps
10.40
13.1
6.1
15.9
7.1
L.R. Amps
73.0
83.1
41.0
110.0
52.0
Scroll
Scroll
Scroll
Scroll
Scroll
1/6
1/4
1/4
1/4
1/4
1.10
1.50
0.80
1.50
0.80
Liquid Line, Inches O.D.*
3/8"
3/8"
3/8"
3/8"
3/8"
Suction Line, Inches O.D.*
7/8"
1 1/8"
1 1/8"
1 1/8"
1 1/8"
3/8"
3/8"
3/8"
3/8"
3/8"
Decibels
Compressor
Type
Condenser Fan Motor
Horsepower
F.L. Amps
Refrigerant System
Liquid Valve Connection, Inches O.D.*
Suction Valve Connection, Inches O.D.*
3
3/4"
3
7/8"
4
7/8"
4
7/8"
4
7/8" 4
Refrigerant Charge
92.0
128.0
128.0
125.0
125.0
Piston Size
0.068
0.080
0.080
0.086
0.086
460-60-3
208/230-60-3
460-60-3
Power Supply
208/230-60-3 208/230-60-3
(1)
Minimum Circuit Ampacity
(2)
Maximum Overcurrent Device
Min / Max Volts
14.1
17.9
8.4
21.4
9.7
20
30
15
35
15
197 / 253
197 / 253
414 / 506
197 / 253
414 / 506
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
196
190
189
197
196
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
(1)
(2)
(3)
(4)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
Installer must supply a 3/4" to 7/8" adapter for suction line connections.
Installer must supply a 7/8" to 1 1/8" adapter for suction line connections.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
9
CONDENSING UNIT SPECIFICATIONS
VSX130181A*
VSX130241A*
VSX130301A*
Cooling Capacity, BTUH
18,000
24,000
30,000
SEER/EER
13 / 11
13 / 11
13 / 11
R.L. Amps
9.00
13.5
12.8
L.R. Amps
48.0
58.3
64.0
VSX130[18-60]1A*
Compressor
High Pressure Switch
Open
N/A
N/A
N/A
Close
N/A
N/A
N/A
Condenser Fan Motor
Horsepower
1/6
1/6
1/6
1.10
1.10
1.10
Liquid Line, Inches O.D.*
3/8"
3/8"
3/8"
Suction Line, Inches O.D.*
3/4"
3/4"
3/4"
Refrigerant Charge
72.0
79.0
81.0
208/230-60-1
208/230-60-1
208/230-60-1
12.3
18.0
17.1
20
30
30
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
149
151
152
F.L. Amps
Power Supply
Minimum Circuit Ampacity
(1)
Maximum Overcurrent Device
(2)
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
VSX130361A*
VSX130421A*
VSX130481A*
Cooling Capacity, BTUH
36,000
42,000
48,000
SEER/EER
13 / 11
13 / 11
13 / 11
R.L. Amps
16.7
L.R. Amps
79.0
17.9
112.0
19.9
109.0
Compressor
High Pressure Switch
Open
N/A
N/A
N/A
Close
N/A
N/A
N/A
Condenser Fan Motor
Horsepower
1/6
1/4
1/4
1.10
1.50
1.50
Liquid Line, Inches O.D.*
3/8"
3/8"
3/8"
Suction Line, Inches O.D.*
3/4"
7/8"
7/8"
Refrigerant Charge
95.0
124.0
128.0
208/230-60-1
208/230-60-1
208/230-60-1
21.9
23.9
26.3
35
40
45
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
197
194
195
F.L. Amps
Power Supply
Minimum Circuit Ampacity
(1)
Maximum Overcurrent Device
(2)
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
(1)
(2)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
10
CONDENSING UNIT SPECIFICATIONS
VSX130181B*
VSX130601B*
Cooling Capacity, BTUH
18,000
60,000
SEER/EER
13 / 11
13 / 11
VSX130[18 & 60]1B*
Compressor
R.L. Amps
6.70
25.0
L.R. Amps
40.0
134.0
High Pressure Switch
Open
N/A
N/A
Close
N/A
N/A
Condenser Fan Motor
Horsepower
1/6
1/4
1.10
1.50
3/8"
3/8"
Suction Line, Inches O.D.*
3/4"
1 1/8"
Refrigerant Charge
71.0
208/230-60-1
125.0
208/230-60-1
9.5
26.3
15
45
1/2 or 3/4
1/2 or 3/4
135
200
F.L. Amps
Liquid Line, Inches O.D.*
Power Supply
Minimum Circuit Ampacity
(1)
Maximum Overcurrent Device
(2)
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping Weight
(1)
(2)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
11
12
75
70
IDB*
17.7
0.58
16
1.28
4.7
227
111
16.4
0.55
16
1.25
4.6
220
107
18.5
0.73
18
1.30
4.8
232
113
17.9
0.70
19
1.29
4.7
230
112
16.5
0.68
20
1.26
4.6
223
108
MBh
17.1
S/T
0.69
Delta T 18
KW
1.25
AMPS 4.6
HI PR 211
LO PR 104
MBh
15.8
S/T
0.66
Delta T 18
KW
1.22
AMPS 4.5
HI PR 205
LO PR 101
MBh
17.9
S/T
0.82
Delta T 20
KW
1.27
AMPS 4.7
HI PR 216
LO PR 106
MBh
17.4
S/T
0.78
Delta T 21
KW
1.26
AMPS 4.6
HI PR 213
LO PR 105
MBh
16.1
S/T
0.75
Delta T 21
KW
1.23
AMPS 4.5
HI PR 207
LO PR 102
600
525
675
600
525
67
17.9
0.51
16
1.30
4.8
235
118
19.4
0.53
16
1.33
4.9
242
122
20.0
0.56
15
1.34
4.9
245
123
17.9
0.38
12
1.29
4.7
233
117
19.4
0.40
12
1.32
4.9
240
121
20.0
0.42
11
1.33
4.9
242
122
* Entering Indoor Dry Bulb Temperature
675
63
18.3
0.60
15
1.29
4.7
230
112
59
MBh
17.6
S/T
0.72
Delta T 17
KW
1.26
AMPS 4.6
HI PR 213
LO PR 105
Airflow
65
19.2
0.33
11
1.34
4.9
245
126
20.8
0.34
11
1.37
5.1
253
130
21.5
0.36
10
1.38
5.1
255
131
-
-
-
71
59
15.7
0.78
22
1.32
4.9
232
108
17.0
0.81
21
1.36
5.0
239
111
17.5
0.85
20
1.37
5.1
242
112
15.4
0.69
19
1.31
4.8
230
106
16.7
0.71
18
1.35
5.0
237
110
17.2
0.75
18
1.36
5.0
239
111
63
67
17.5
0.53
16
1.39
5.2
264
125
19.0
0.55
16
1.43
5.3
272
129
19.5
0.58
15
1.44
5.3
275
130
17.5
0.40
12
1.38
5.1
261
124
19.0
0.41
12
1.42
5.3
269
127
19.6
0.43
12
1.43
5.3
272
129
18.8
0.34
11
1.44
5.3
275
133
20.3
0.35
11
1.47
5.5
284
137
21.0
0.37
11
1.48
5.5
287
139
-
-
-
71
59
15.3
0.80
22
1.41
5.3
264
112
16.6
0.83
21
1.44
5.4
272
115
17.1
0.87
20
1.45
5.5
275
116
15.1
0.71
19
1.39
5.2
261
111
16.3
0.73
18
1.43
5.4
270
114
16.8
0.77
18
1.44
5.4
272
115
15.8
0.72
20
1.43
5.4
284
119
17.1
0.74
19
1.47
5.6
293
123
17.6
0.78
19
1.48
5.6
296
124
15.6
0.59
16
1.42
5.4
281
118
16.9
0.61
16
1.46
5.5
290
121
17.4
0.64
15
1.47
5.6
293
123
17.1
0.54
16
1.48
5.6
300
130
18.5
0.56
16
1.52
5.8
309
134
19.1
0.59
15
1.53
5.8
313
135
17.1
0.41
12
1.47
5.6
297
129
18.5
0.42
12
1.50
5.7
306
132
19.1
0.44
12
1.52
5.8
309
134
18.3
0.35
11
1.53
5.8
313
138
19.9
0.36
11
1.56
6.0
323
143
20.5
0.38
11
1.58
6.0
326
144
-
-
-
15.0
0.83
22
1.48
5.7
301
117
16.2
0.86
21
1.51
5.8
310
121
16.7
0.90
20
1.52
5.9
313
122
14.7
0.73
19
1.46
5.6
298
116
15.9
0.76
18
1.50
5.8
307
120
16.4
0.79
18
1.51
5.8
310
121
15.4
0.74
20
1.51
5.8
324
125
16.7
0.77
20
1.54
6.0
334
129
17.2
0.81
19
1.56
6.0
337
130
15.2
0.61
16
1.49
5.7
320
124
16.5
0.63
16
1.53
5.9
330
127
17.0
0.66
15
1.54
6.0
334
129
16.7
0.56
16
1.55
6.0
342
136
18.1
0.58
16
1.59
6.2
352
141
18.6
0.61
15
1.61
6.2
356
142
16.7
0.42
12
1.54
5.9
338
135
18.1
0.44
12
1.58
6.1
349
139
18.6
0.46
12
1.59
6.2
352
141
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
NOTE: Shaded area is ACCA (TVA) conditions
16.2
0.70
20
1.35
5.0
250
114
17.5
0.73
19
1.38
5.1
258
118
18.0
0.76
19
1.40
5.2
260
119
16.0
0.57
16
1.34
4.9
247
113
17.3
0.60
16
1.37
5.1
255
117
17.9
0.63
15
1.38
5.1
258
118
75
MODEL: GSX130181A* / CA*F1824*6** / ZP16K5E-PFV
17.9
0.36
11
1.61
6.2
357
145
19.4
0.37
11
1.65
6.4
368
150
20.0
0.39
11
1.66
6.5
371
151
-
-
-
71
EXPANDED PERFORMANCE DATA
59
14.2
0.86
21
1.54
6.0
338
123
15.4
0.89
21
1.57
6.2
349
127
15.9
0.93
20
1.59
6.3
352
128
14.0
0.76
18
1.52
6.0
335
122
15.1
0.78
18
1.56
6.1
345
126
15.6
0.82
17
1.57
6.2
349
127
63
14.6
0.77
20
1.57
6.2
364
131
15.8
0.80
19
1.61
6.3
375
135
16.3
0.84
19
1.62
6.4
379
136
14.5
0.63
16
1.56
6.1
361
130
15.7
0.65
16
1.60
6.3
372
134
16.2
0.69
15
1.61
6.3
375
135
67
15.8
0.58
16
1.62
6.4
385
143
17.2
0.60
16
1.66
6.6
396
147
17.7
0.63
15
1.67
6.6
400
149
15.9
0.44
12
1.61
6.3
381
141
17.2
0.45
12
1.65
6.5
392
146
17.7
0.48
11
1.66
6.6
396
147
105
17.0
0.37
11
1.67
6.6
401
152
18.4
0.39
11
1.71
6.8
414
157
19.0
0.41
11
1.73
6.9
418
158
-
-
-
71
59
13.2
0.87
20
1.59
6.4
374
127
14.3
0.90
20
1.63
6.6
386
131
14.7
0.94
19
1.64
6.6
389
133
12.9
0.76
17
1.57
6.3
370
126
14.0
0.79
17
1.61
6.5
382
130
14.4
0.83
16
1.63
6.6
385
131
63
13.5
0.78
18
1.62
6.5
402
135
14.7
0.80
18
1.66
6.7
415
140
15.1
0.84
17
1.68
6.8
419
141
13.4
0.64
15
1.61
6.5
398
134
14.5
0.66
15
1.65
6.7
411
138
15.0
0.69
14
1.66
6.7
415
140
67
14.7
0.59
15
1.67
6.8
425
148
15.9
0.61
15
1.72
7.0
438
152
16.4
0.64
14
1.73
7.0
442
154
14.7
0.44
11
1.66
6.7
421
146
15.9
0.46
11
1.70
6.9
434
151
16.4
0.48
11
1.72
7.0
438
152
115
15.7
0.38
10
1.73
7.0
443
157
17.1
0.39
10
1.77
7.2
457
162
17.6
0.41
10
1.79
7.3
461
164
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130181A*
85
80
IDB*
600
18.4
0.87
24
1.31
4.8
234
114
19.8
0.82
22
1.36
5.0
250
126
21.2
0.67
19
1.40
5.2
261
134
71
21.3
0.51
15
1.39
5.2
258
132
20.7
0.49
16
1.38
5.1
255
131
19.1
0.47
16
1.35
5.0
248
127
19.0
0.61
20
1.36
5.0
250
128
18.0
0.90
25
1.28
4.7
218
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
18.9
0.91
23
1.32
4.9
237
115
67
19.9
0.69
19
1.35
5.0
247
124
19.4
0.66
19
1.34
4.9
245
123
17.9
0.63
20
1.31
4.8
238
119
MBh
16.6 17.0 17.8
S/T
0.87 0.84 0.76
Delta T 25
25
24
525
KW
1.25 1.28 1.32
AMPS 4.6
4.7
4.9
HI PR 211
227
240
LO PR 104
110
121
* Entering Indoor Dry Bulb Temperature
18.6
0.94
24
1.29
4.8
220
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
63
18.7
0.84
21
1.31
4.8
234
114
18.1
0.81
22
1.30
4.8
232
113
16.7
0.78
23
1.27
4.7
225
109
20.5
0.64
20
1.39
5.2
258
132
59
18.3
0.90
22
1.28
4.7
218
107
17.7
0.86
23
1.27
4.7
216
106
16.4
0.83
24
1.24
4.5
209
103
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
19.3
0.78
23
1.35
5.0
247
124
675
525
600
675
Airflow
65
16.3
0.90
26
1.35
5.0
237
110
17.6
0.93
25
1.38
5.1
244
113
18.1
0.98
24
1.39
5.1
247
114
59
17.8
0.93
23
1.38
5.1
244
113
17.3
0.89
24
1.37
5.1
242
112
16.0
0.86
24
1.34
4.9
235
109
16.6
0.87
25
1.37
5.1
255
117
NOTE:
18.0
0.90
25
1.41
5.2
263
120
18.5
0.94
24
1.42
5.3
265
122
63
18.2
0.88
22
1.41
5.2
263
120
17.7
0.83
23
1.40
5.2
260
119
16.3
0.80
23
1.36
5.0
252
116
18.8
0.81
23
1.45
5.4
278
131
19.4
0.85
22
1.46
5.4
280
133
67
19.5
0.71
19
1.45
5.4
278
131
18.9
0.68
20
1.44
5.3
275
130
17.4
0.65
20
1.41
5.2
267
126
20.1
0.66
20
1.50
5.6
290
140
20.7
0.69
19
1.51
5.7
292
141
71
20.8
0.53
15
1.50
5.6
290
140
20.2
0.51
16
1.49
5.5
287
139
18.6
0.49
16
1.45
5.4
278
134
17.2
0.96
25
1.46
5.5
278
118
17.7
1.00
24
1.47
5.6
281
119
59
17.4
0.96
23
1.46
5.5
278
118
16.9
0.91
24
1.45
5.5
275
116
15.6
0.88
24
1.42
5.3
267
113
17.4 18.5 15.9
0.78 0.64 0.92
24
21
26
1.42 1.46 1.43
5.2
5.4
5.4
269
281
269
127
136
114
Shaded area is AHRI
75
MODEL: GSX130181AA / CA*F1824*6** / ZP16K5E-PFV
18.4
0.83
23
1.54
5.9
316
137
18.9
0.87
22
1.55
5.9
319
138
19.6
0.68
20
1.59
6.1
329
145
20.2
0.71
19
1.60
6.1
333
147
16.2 16.9 18.1
0.89 0.80 0.65
25
24
21
1.46 1.50 1.55
5.5
5.7
5.9
290
306
319
121
132
141
Rating Conditions
17.5
0.92
25
1.49
5.7
299
125
18.1
0.97
24
1.51
5.7
302
126
15.5
0.95
26
1.50
5.8
307
120
16.8
0.99
25
1.54
5.9
316
123
17.3
1.00
24
1.55
6.0
320
125
15.8
0.92
25
1.53
5.9
330
127
17.1
0.95
25
1.57
6.1
341
131
17.6
1.00
24
1.58
6.1
344
133
16.5
0.83
24
1.58
6.1
349
139
17.9
0.86
24
1.62
6.3
360
143
18.4
0.90
23
1.63
6.3
363
145
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
17.8 19.0 20.3 17.0
17.4
18.5
0.90 0.73 0.55 1.00
0.93
0.75
22
19
15
23
22
19
1.49 1.54 1.59 1.54
1.57
1.62
5.7
5.9
6.1
5.9
6.1
6.3
299
316
329
316
341
360
125
137
145
123
131
143
17.3 18.5 19.7 16.5
16.8
18.0
0.86 0.70 0.52 0.94
0.88
0.72
20
23
20
16
24
23
1.61
1.48 1.53 1.58 1.52
1.56
5.6
5.8
6.0
5.9
6.0
6.2
296
313
326
313
337
356
124
135
144
122
130
142
15.9 17.0 18.2 15.2
15.6
16.6
0.83 0.67 0.50 0.91
0.85
0.69
23
20
16
24
23
20
1.45 1.49 1.54 1.49
1.52
1.57
5.5
5.7
5.9
5.7
5.9
6.0
287
303
316
304
327
345
120
131
140
119
126
138
17.6
0.67
21
1.63
6.3
364
148
19.1
0.70
20
1.67
6.5
375
153
19.7
0.73
20
1.69
6.6
379
154
71
19.8
0.56
15
1.67
6.5
375
153
19.2
0.54
16
1.66
6.5
371
151
17.8
0.52
16
1.62
6.3
360
147
EXPANDED PERFORMANCE DATA
14.7
0.99
25
1.56
6.1
345
126
15.9
1.00
24
1.60
6.3
356
129
16.4
1.00
22
1.61
6.4
360
131
59
16.1
1.00
22
1.60
6.3
356
129
15.7
0.98
23
1.59
6.3
352
128
14.5
0.94
24
1.55
6.1
342
124
15.0
0.95
25
1.59
6.3
372
134
16.2
0.99
25
1.63
6.5
383
138
16.7
1.00
23
1.65
6.5
387
139
63
16.5
0.96
22
1.63
6.5
383
138
16.0
0.92
22
1.62
6.4
379
136
14.8
0.88
23
1.58
6.2
368
132
15.7
0.86
24
1.65
6.5
392
146
17.0
0.89
23
1.69
6.7
405
150
17.5
0.94
22
1.70
6.7
409
152
67
17.6
0.78
19
1.69
6.7
405
150
17.1
0.75
20
1.67
6.6
401
149
15.8
0.72
20
1.63
6.4
388
144
105
16.8
0.70
20
1.70
6.7
409
155
18.2
0.72
20
1.74
6.9
422
160
18.7
0.76
19
1.76
7.0
426
162
71
18.8
0.58
15
1.74
6.9
422
160
18.3
0.56
16
1.73
6.9
418
158
16.9
0.54
16
1.69
6.7
405
154
13.6
1.00
24
1.61
6.5
382
130
14.8
1.00
23
1.65
6.7
393
134
15.2
1.00
21
1.67
6.8
397
135
59
14.9
1.00
20
1.65
6.7
393
134
14.5
0.99
22
1.64
6.6
389
133
13.4
0.95
22
1.60
6.4
378
129
13.9
0.96
23
1.65
6.7
411
138
15.0
1.00
23
1.69
6.9
423
142
15.5
1.00
21
1.70
6.9
427
144
63
15.3
0.97
20
1.69
6.9
423
142
14.8
0.92
21
1.68
6.8
419
141
13.7
0.89
21
1.64
6.6
406
137
14.5
0.87
22
1.70
6.9
434
151
15.8
0.90
22
1.75
7.1
447
155
16.2
0.94
21
1.76
7.2
451
157
67
16.3
0.79
18
1.75
7.1
447
155
15.8
0.75
18
1.73
7.0
443
154
14.6
0.73
19
1.69
6.8
429
149
115
15.5
0.70
19
1.76
7.2
452
161
16.8
0.73
19
1.80
7.4
466
166
17.3
0.77
18
1.82
7.4
471
167
71
17.4
0.59
14
1.80
7.4
466
166
16.9
0.56
15
1.79
7.3
462
164
15.6
0.54
15
1.74
7.1
448
159
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130181A*
13
14
75
70
IDB*
22.7
0.58
15
1.64
5.8
242
106
20.9
0.56
15
1.61
5.6
235
103
23.6
0.75
18
1.67
5.9
247
108
22.9
0.71
18
1.66
5.9
244
107
21.1
0.69
19
1.62
5.7
237
104
MBh
21.9
S/T
0.70
Delta T 17
KW
1.61
AMPS 5.7
HI PR 225
LO PR 100
MBh
20.2
S/T
0.67
Delta T 18
KW
1.58
AMPS 5.5
HI PR 218
LO PR 97
MBh
22.9
S/T
0.83
Delta T 19
KW
1.64
AMPS 5.8
HI PR 229
LO PR 102
MBh
22.3
S/T
0.79
Delta T 20
KW
1.62
AMPS 5.7
HI PR 227
LO PR 101
MBh
20.5
S/T
0.77
Delta T 20
KW
1.59
AMPS 5.6
HI PR 220
LO PR 98
810
709
911
810
709
67
22.9
0.52
15
1.67
5.9
250
114
24.8
0.54
15
1.71
6.1
258
117
25.5
0.56
15
1.72
6.1
261
118
22.9
0.39
12
1.65
5.8
248
112
24.8
0.40
11
1.69
6.0
256
116
25.6
0.42
11
1.70
6.0
258
117
* Entering Indoor Dry Bulb Temperature
911
63
23.4
0.61
14
1.66
5.9
244
107
59
MBh
22.5
S/T
0.73
Delta T 17
KW
1.62
AMPS 5.7
HI PR 227
LO PR 101
Airflow
65
24.6
0.33
11
1.72
6.1
261
121
26.6
0.35
10
1.76
6.3
269
125
27.4
0.36
10
1.77
6.3
272
126
-
-
-
71
59
20.1
0.79
21
1.70
6.0
247
103
21.7
0.82
20
1.74
6.2
255
107
22.4
0.86
20
1.75
6.2
257
108
19.7
0.70
18
1.69
6.0
245
102
21.4
0.72
18
1.73
6.1
252
106
22.0
0.76
17
1.74
6.2
255
107
63
67
22.4
0.54
16
1.79
6.4
281
120
24.2
0.56
15
1.83
6.5
290
124
24.9
0.58
15
1.84
6.6
293
125
22.4
0.40
12
1.77
6.3
278
119
24.3
0.42
12
1.81
6.5
287
123
25.0
0.44
11
1.83
6.5
290
124
24.0
0.35
11
1.84
6.6
293
128
26.0
0.36
11
1.88
6.8
302
132
26.8
0.38
10
1.90
6.9
305
133
-
-
-
71
59
19.6
0.81
21
1.80
6.5
281
107
21.2
0.84
20
1.84
6.7
290
111
21.9
0.89
20
1.86
6.8
293
112
19.3
0.72
18
1.79
6.5
278
106
20.9
0.74
18
1.83
6.7
287
110
21.5
0.78
17
1.84
6.7
290
111
20.2
0.73
19
1.84
6.7
303
114
21.8
0.76
19
1.88
6.9
312
118
22.5
0.79
18
1.89
6.9
315
119
20.0
0.60
15
1.82
6.6
300
113
21.6
0.62
15
1.87
6.8
309
117
22.3
0.65
15
1.88
6.9
312
118
21.8
0.55
16
1.89
6.9
320
125
23.6
0.57
15
1.94
7.1
329
129
24.4
0.60
15
1.95
7.2
333
130
21.9
0.41
12
1.88
6.9
316
124
23.7
0.43
12
1.92
7.0
326
127
24.4
0.45
11
1.94
7.1
329
129
23.4
0.35
11
1.95
7.2
333
133
25.4
0.37
11
2.00
7.4
344
137
26.1
0.39
10
2.01
7.5
347
138
-
-
-
19.1
0.84
21
1.89
7.0
320
113
20.7
0.87
20
1.93
7.2
330
116
21.3
0.91
20
1.95
7.3
333
118
18.8
0.74
18
1.87
6.9
317
112
20.4
0.77
18
1.92
7.1
327
115
21.0
0.80
17
1.93
7.2
330
116
23.1
0.59
15
2.03
7.6
375
135
21.3
0.57
16
1.99
7.4
364
131
19.7
0.75
19
1.93
7.2
345
120
23.8
0.62
15
2.05
7.7
379
136
22.0
0.82
18
1.99
7.4
359
125
21.3
0.78
19
1.97
7.4
355
124
21.3
0.43
12
1.97
7.3
360
130
23.1
0.44
12
2.02
7.5
371
134
23.8
0.47
11
2.03
7.6
375
135
19.5
0.62
16
1.91
7.1
341
119
21.1
0.64
15
1.96
7.3
352
123
21.7
0.67
15
1.97
7.4
355
124
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
NOTE: Shaded area is ACCA (TVA) conditions
20.7
0.71
19
1.74
6.2
266
110
22.4
0.74
19
1.78
6.3
274
113
23.0
0.77
18
1.79
6.4
277
115
20.4
0.58
15
1.72
6.1
263
109
22.2
0.61
15
1.76
6.3
272
112
22.8
0.63
15
1.78
6.3
274
113
75
MODEL: GSX130241A* / CA*F1824*6** / ZP20K5-PFV
22.9
0.37
11
2.05
7.7
380
140
24.8
0.38
11
2.10
7.9
391
144
25.5
0.40
10
2.11
8.0
395
145
-
-
-
71
EXPANDED PERFORMANCE DATA
59
18.2
0.87
21
1.96
7.4
360
118
19.7
0.90
20
2.01
7.6
371
122
20.3
0.95
19
2.03
7.7
375
123
17.8
0.77
18
1.95
7.4
357
117
19.3
0.80
17
1.99
7.6
368
121
19.9
0.83
17
2.01
7.6
371
122
63
18.7
0.78
19
2.00
7.6
388
126
20.2
0.81
19
2.05
7.8
400
130
20.9
0.85
18
2.07
7.9
404
131
18.5
0.64
15
1.99
7.5
384
125
20.0
0.66
15
2.04
7.8
396
128
20.6
0.70
15
2.05
7.8
400
130
67
20.2
0.59
15
2.07
7.9
409
137
21.9
0.61
15
2.12
8.1
422
142
22.6
0.64
15
2.13
8.2
426
143
20.3
0.44
12
2.05
7.8
405
136
22.0
0.46
11
2.10
8.0
418
140
22.6
0.48
11
2.12
8.1
422
142
105
21.7
0.38
11
2.13
8.2
427
146
23.5
0.39
11
2.18
8.4
440
151
24.2
0.41
10
2.20
8.5
445
152
-
-
-
71
59
16.8
0.88
19
2.03
7.9
398
122
18.2
0.91
19
2.08
8.1
410
126
18.8
0.96
18
2.09
8.2
415
127
16.5
0.77
17
2.01
7.8
394
121
17.9
0.80
16
2.06
8.0
406
125
18.4
0.84
16
2.08
8.1
410
126
63
17.3
0.79
18
2.07
8.1
428
130
18.8
0.82
17
2.12
8.3
442
134
19.3
0.86
17
2.14
8.4
446
136
17.1
0.65
14
2.05
8.0
424
129
18.6
0.67
14
2.10
8.2
437
133
19.1
0.70
14
2.12
8.3
442
134
67
18.7
0.60
14
2.13
8.3
452
142
20.3
0.62
14
2.19
8.6
466
146
20.9
0.65
14
2.20
8.7
471
148
18.8
0.45
11
2.12
8.3
448
141
20.3
0.46
11
2.17
8.5
462
145
21.0
0.49
10
2.19
8.6
466
146
115
20.1
0.38
10
2.20
8.7
472
151
21.8
0.40
10
2.26
8.9
486
156
22.4
0.42
9
2.27
9.0
491
158
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130241A*
85
80
IDB*
24.2
0.92
23
1.69
6.0
252
111
23.5
0.88
24
1.68
6.0
249
109
21.7
0.85
24
1.64
5.8
242
106
MBh
23.7
S/T
0.96
Delta T 23
KW
1.66
AMPS 5.9
HI PR 234
LO PR 104
MBh
23.0
S/T
0.91
Delta T 24
KW
1.65
AMPS 5.8
HI PR 232
LO PR 103
MBh
21.3
S/T
0.88
Delta T 24
KW
1.61
AMPS 5.7
HI PR 225
LO PR 100
810
709
22.7
0.77
23
1.69
6.0
255
116
24.6
0.80
22
1.73
6.2
263
120
25.3
0.83
21
1.74
6.2
266
121
67
25.5
0.70
18
1.73
6.2
263
120
24.7
0.67
19
1.72
6.1
261
118
22.8
0.64
19
1.68
5.9
253
115
* Entering Indoor Dry Bulb Temperature
911
709
810
911
63
23.8
0.86
21
1.68
6.0
249
109
23.1
0.82
21
1.67
5.9
247
108
21.4
0.79
22
1.63
5.8
240
105
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
59
23.3
0.91
22
1.65
5.8
232
103
22.6
0.87
22
1.64
5.8
229
102
20.9
0.84
23
1.60
5.6
223
99
Airflow
65
24.2
0.62
20
1.74
6.2
266
123
26.2
0.65
19
1.78
6.4
275
127
27.0
0.68
18
1.80
6.4
277
129
71
27.2
0.52
14
1.78
6.4
275
127
26.4
0.50
15
1.77
6.3
272
126
24.4
0.48
15
1.73
6.2
264
122
20.8
0.91
25
1.73
6.1
252
105
22.5
0.95
24
1.77
6.3
260
109
23.2
0.99
23
1.78
6.4
263
110
59
22.8
0.95
22
1.77
6.3
260
109
22.1
0.90
23
1.75
6.2
257
108
20.4
0.87
23
1.71
6.1
250
104
22.2
0.80
23
1.81
6.5
287
122
24.0
0.82
22
1.86
6.7
296
126
24.8
0.86
22
1.87
6.7
298
128
67
24.9
0.72
18
1.86
6.7
296
126
24.2
0.69
19
1.84
6.6
293
125
22.3
0.67
19
1.80
6.4
284
121
23.7
0.65
20
1.87
6.7
299
130
25.6
0.67
19
1.91
6.9
308
134
26.4
0.70
19
1.93
7.0
311
136
71
26.6
0.54
15
1.91
6.9
308
134
25.8
0.52
15
1.90
6.9
305
133
23.8
0.50
15
1.86
6.7
296
129
20.3
0.94
25
1.83
6.7
287
110
22.0
0.97
24
1.87
6.8
296
113
22.6
1.00
23
1.89
6.9
299
114
59
22.2
1.00
22
1.87
6.8
296
113
21.6
0.93
23
1.86
6.8
293
112
19.9
0.89
23
1.81
6.6
284
109
20.7
0.90
24
1.87
6.8
309
117
22.4
0.94
24
1.91
7.0
318
120
23.1
0.98
23
1.92
7.1
321
121
21.7
0.82
23
1.92
7.0
326
127
23.5
0.85
23
1.97
7.2
336
131
24.2
0.89
22
1.98
7.3
339
133
23.1
0.66
20
1.98
7.3
340
136
25.0
0.69
19
2.03
7.5
351
140
25.8
0.72
19
2.05
7.6
354
141
19.8
0.97
25
1.92
7.1
327
115
21.4
1.00
24
1.96
7.3
337
119
22.1
1.00
22
1.98
7.4
340
120
20.2
0.93
24
1.96
7.3
352
122
21.9
0.97
24
2.00
7.5
363
126
22.5
1.00
23
2.02
7.6
366
128
21.1
0.84
23
2.02
7.5
371
134
22.9
0.87
23
2.07
7.8
383
138
23.6
0.92
22
2.08
7.8
387
139
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
22.7 24.3 26.0 21.7
22.2
23.7
0.91 0.74 0.55 1.00
0.94
0.77
21
18
15
22
21
18
1.91 1.97 2.03 1.96
2.00
2.07
7.0
7.2
7.5
7.3
7.5
7.8
318
336
351
337
363
383
120
131
140
119
126
138
22.1 23.6 25.2 21.1
21.5
23.0
0.87 0.71 0.53 0.96
0.90
0.73
19
22
19
15
23
22
2.05
1.89 1.95 2.01 1.95
1.99
6.9
7.2
7.5
7.3
7.4
7.7
315
333
347
334
359
379
119
130
138
118
125
137
20.4 21.8 23.3 19.4
19.9
21.2
0.84 0.68 0.51 0.92
0.86
0.70
22
19
15
23
22
19
1.85 1.91 1.97 1.90
1.94
2.00
6.8
7.0
7.2
7.1
7.2
7.5
306
323
337
324
348
368
115
126
134
114
121
132
NOTE: Shaded area is AHRI Rating Conditions
21.2
0.88
24
1.76
6.3
271
112
22.9
0.91
24
1.80
6.5
280
116
23.6
0.96
23
1.82
6.5
283
117
63
23.3
0.89
21
1.80
6.5
280
116
22.6
0.85
22
1.79
6.4
277
115
20.9
0.82
22
1.75
6.2
269
111
75
MODEL: GSX130241AA / CA*F1824*6** / ZP20K5-PFV
22.5
0.68
20
2.08
7.8
387
142
24.4
0.71
20
2.13
8.0
399
147
25.1
0.74
19
2.15
8.1
403
148
71
25.3
0.57
15
2.13
8.0
399
147
24.6
0.55
15
2.11
8.0
395
145
22.7
0.53
15
2.06
7.7
383
141
EXPANDED PERFORMANCE DATA
18.8
1.00
24
1.99
7.6
368
121
20.4
1.00
23
2.04
7.8
379
124
21.0
1.00
21
2.06
7.9
383
126
59
20.6
1.00
21
2.04
7.8
379
124
20.0
0.99
23
2.03
7.7
375
123
18.5
0.96
23
1.98
7.5
364
119
19.2
0.97
24
2.03
7.8
396
128
20.8
1.00
24
2.08
8.0
408
132
21.4
1.00
22
2.10
8.1
412
134
63
21.1
1.00
21
2.08
8.0
408
132
20.5
0.93
22
2.07
7.9
404
131
18.9
0.90
22
2.02
7.7
392
127
20.1
0.87
23
2.10
8.0
418
140
21.7
0.91
22
2.15
8.3
431
144
22.4
0.95
21
2.17
8.3
435
146
67
22.5
0.79
18
2.15
8.3
431
144
21.9
0.76
19
2.13
8.2
426
143
20.2
0.73
19
2.08
7.9
414
139
105
21.4
0.71
20
2.16
8.3
436
149
23.2
0.74
19
2.22
8.6
449
154
23.9
0.77
19
2.24
8.7
454
155
71
24.1
0.59
14
2.22
8.6
449
154
23.4
0.57
15
2.20
8.5
445
152
21.6
0.55
15
2.15
8.3
431
148
17.4
1.00
23
2.06
8.0
406
125
18.9
1.00
21
2.11
8.3
419
129
19.4
1.00
20
2.13
8.3
423
130
59
19.1
1.00
19
2.11
8.3
419
129
18.5
1.00
21
2.09
8.2
415
127
17.1
0.97
21
2.04
8.0
402
124
17.7
0.98
22
2.10
8.2
437
133
19.2
1.00
22
2.15
8.5
451
137
19.8
1.00
20
2.17
8.5
455
138
63
19.5
1.00
20
2.15
8.5
451
137
18.9
0.94
20
2.14
8.4
446
136
17.5
0.91
21
2.09
8.2
433
131
18.6
0.88
21
2.17
8.5
462
145
20.1
0.91
21
2.22
8.8
476
149
20.7
0.96
20
2.24
8.8
481
151
67
20.8
0.80
17
2.22
8.8
476
149
20.2
0.76
18
2.20
8.7
471
148
18.7
0.74
18
2.15
8.4
457
144
115
19.8
0.71
18
2.24
8.8
481
154
21.5
0.74
18
2.29
9.1
496
159
22.1
0.78
17
2.31
9.2
501
161
71
22.3
0.60
13
2.29
9.1
496
159
21.6
0.57
14
2.27
9.0
491
158
20.0
0.55
14
2.22
8.7
477
153
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130241A*
15
16
75
70
IDB*
28.0
0.59
15
2.01
7.1
255
112
25.8
0.57
15
1.97
6.9
248
109
29.1
0.76
17
2.04
7.2
261
115
28.3
0.72
18
2.03
7.1
258
114
26.1
0.69
18
1.98
7.0
250
110
MBh
27.0
S/T
0.71
Delta T 17
KW
1.97
AMPS 6.9
HI PR 237
LO PR 106
MBh
24.9
S/T
0.68
Delta T 17
KW
1.93
AMPS 6.7
HI PR 230
LO PR 103
MBh
28.3
S/T
0.84
Delta T 19
KW
2.00
AMPS 7.0
HI PR 242
LO PR 108
MBh
27.5
S/T
0.81
Delta T 19
KW
1.99
AMPS 7.0
HI PR 240
LO PR 107
MBh
25.4
S/T
0.78
Delta T 20
KW
1.94
AMPS 6.8
HI PR 233
LO PR 104
1050
919
1181
1050
919
67
28.3
0.53
15
2.04
7.2
264
120
30.6
0.55
15
2.09
7.4
272
124
31.5
0.57
14
2.10
7.5
275
125
28.3
0.40
11
2.02
7.1
262
119
30.7
0.41
11
2.07
7.3
270
123
31.6
0.43
11
2.08
7.4
272
124
* Entering Indoor Dry Bulb Temperature
1181
63
28.8
0.62
14
2.03
7.1
258
114
59
MBh
27.8
S/T
0.74
Delta T 16
KW
1.99
AMPS 7.0
HI PR 240
LO PR 107
Airflow
65
30.3
0.34
10
2.10
7.5
276
128
32.9
0.35
10
2.15
7.7
284
132
33.9
0.37
10
2.16
7.7
287
133
-
-
-
71
59
24.8
0.81
20
2.08
7.3
261
109
26.8
0.84
20
2.13
7.6
269
113
27.6
0.88
19
2.14
7.6
272
114
24.4
0.71
17
2.06
7.3
258
108
26.4
0.73
17
2.11
7.5
266
112
27.2
0.77
16
2.13
7.6
269
113
63
67
27.6
0.55
15
2.19
7.8
297
127
29.9
0.57
15
2.24
8.0
306
131
30.8
0.59
14
2.25
8.1
309
132
27.7
0.41
11
2.17
7.7
294
126
30.0
0.43
11
2.22
7.9
303
130
30.9
0.45
11
2.24
8.0
306
131
29.6
0.35
10
2.25
8.1
309
135
32.1
0.36
10
2.31
8.3
319
140
33.1
0.38
10
2.32
8.4
322
141
-
-
-
71
59
24.2
0.83
20
2.20
8.0
297
114
26.2
0.86
20
2.25
8.2
306
117
27.0
0.90
19
2.27
8.3
309
118
23.8
0.73
17
2.19
7.9
294
113
25.8
0.75
17
2.24
8.1
303
116
26.5
0.79
16
2.25
8.2
306
117
24.9
0.74
18
2.25
8.2
319
121
27.0
0.77
18
2.30
8.4
329
125
27.8
0.80
17
2.32
8.5
333
126
24.6
0.61
15
2.23
8.1
316
120
26.7
0.63
15
2.28
8.3
326
123
27.5
0.66
14
2.30
8.4
329
125
26.9
0.56
15
2.32
8.5
337
132
29.2
0.58
15
2.37
8.7
348
136
30.1
0.61
14
2.39
8.8
351
138
27.0
0.42
11
2.30
8.4
334
131
29.3
0.44
11
2.35
8.6
344
135
30.1
0.46
11
2.37
8.7
348
136
28.9
0.36
10
2.39
8.8
352
141
31.3
0.37
10
2.45
9.0
363
145
32.3
0.39
10
2.47
9.1
366
146
-
-
-
23.6
0.85
20
2.31
8.5
338
119
25.6
0.88
20
2.37
8.8
348
123
26.3
0.93
19
2.38
8.9
352
124
23.2
0.75
17
2.29
8.5
335
118
25.1
0.78
17
2.35
8.7
345
122
25.9
0.82
16
2.37
8.8
348
123
24.3
0.76
19
2.36
8.8
364
127
26.3
0.79
18
2.41
9.0
375
131
27.1
0.83
17
2.43
9.1
379
132
24.0
0.63
15
2.34
8.7
360
126
26.1
0.65
15
2.40
8.9
371
130
26.8
0.68
14
2.41
9.0
375
131
26.3
0.58
15
2.43
9.1
384
139
28.5
0.60
15
2.49
9.3
396
143
29.3
0.63
14
2.51
9.4
400
144
26.3
0.43
11
2.41
9.0
380
137
28.5
0.45
11
2.47
9.2
392
142
29.4
0.47
11
2.49
9.3
396
143
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
NOTE: Shaded area is ACCA (TVA) conditions
25.5
0.72
18
2.12
7.5
281
116
27.6
0.75
18
2.17
7.7
290
120
28.5
0.78
17
2.19
7.8
292
121
25.2
0.59
15
2.11
7.5
278
115
27.4
0.61
15
2.16
7.7
287
119
28.2
0.64
14
2.17
7.7
289
120
75
MODEL: GSX130301A* / CA*F3030*6** / ZP24K5E-PFV
28.2
0.37
10
2.51
9.4
401
148
30.6
0.38
10
2.57
9.7
413
152
31.5
0.40
10
2.59
9.8
417
154
-
-
-
71
EXPANDED PERFORMANCE DATA
59
22.4
0.88
20
2.40
9.1
380
125
24.3
0.92
20
2.46
9.4
392
129
25.0
0.96
19
2.48
9.5
396
130
22.0
0.78
17
2.38
9.0
376
124
23.9
0.81
17
2.44
9.3
388
128
24.6
0.85
16
2.46
9.4
392
129
63
23.1
0.79
18
2.45
9.3
409
133
25.0
0.82
18
2.51
9.6
422
137
25.8
0.86
17
2.53
9.7
426
139
22.8
0.65
15
2.43
9.2
405
132
24.7
0.67
15
2.49
9.5
418
136
25.5
0.71
14
2.51
9.6
422
137
67
25.0
0.60
15
2.53
9.6
432
145
27.1
0.62
15
2.59
9.9
446
150
27.9
0.65
14
2.61
10.0
450
151
25.0
0.45
11
2.51
9.6
428
144
27.1
0.47
11
2.57
9.8
441
148
27.9
0.49
11
2.59
9.9
445
150
105
26.8
0.39
10
2.61
10.0
451
155
29.0
0.40
10
2.67
10.3
465
160
29.9
0.42
10
2.70
10.4
469
161
-
-
-
71
59
20.8
0.89
19
2.48
9.6
420
130
22.5
0.93
18
2.54
9.9
433
134
23.2
0.97
17
2.56
10.0
437
135
20.4
0.78
16
2.46
9.6
416
128
22.1
0.81
16
2.52
9.8
429
132
22.8
0.85
15
2.54
9.9
433
133
63
21.4
0.80
17
2.53
9.9
452
138
23.2
0.83
17
2.60
10.2
466
142
23.9
0.87
16
2.62
10.3
471
143
21.2
0.66
14
2.51
9.8
448
136
22.9
0.68
14
2.57
10.1
461
141
23.6
0.71
13
2.60
10.2
466
142
67
23.1
0.60
14
2.61
10.2
477
150
25.1
0.63
14
2.68
10.5
492
155
25.8
0.66
13
2.70
10.6
497
157
23.2
0.45
11
2.59
10.1
473
149
25.1
0.47
10
2.66
10.4
487
154
25.9
0.49
10
2.68
10.5
492
155
115
24.8
0.39
10
2.70
10.6
498
160
26.9
0.40
9
2.76
10.9
513
165
27.7
0.42
9
2.79
11.0
519
167
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130301A*
85
80
IDB*
28.6
0.83
21
2.04
7.2
261
115
26.4
0.80
21
1.99
7.0
253
111
29.9
0.94
22
2.07
7.3
266
117
29.0
0.89
23
2.06
7.3
263
116
26.8
0.86
23
2.01
7.1
255
112
MBh
28.0
S/T
0.88
Delta T 22
KW
2.00
AMPS 7.0
HI PR 242
LO PR 108
MBh
25.8
S/T
0.85
Delta T 22
KW
1.96
AMPS 6.9
HI PR 235
LO PR 105
MBh
29.3
S/T
0.97
Delta T 22
KW
2.03
AMPS 7.2
HI PR 247
LO PR 110
MBh
28.5
S/T
0.93
Delta T 23
KW
2.02
AMPS 7.1
HI PR 245
LO PR 109
MBh
26.3
S/T
0.89
Delta T 23
KW
1.97
AMPS 6.9
HI PR 237
LO PR 106
1050
919
1181
1050
919
28.0
0.78
22
2.07
7.3
270
123
30.4
0.81
21
2.12
7.5
278
127
31.3
0.85
21
2.13
7.6
281
128
28.2
0.65
18
2.05
7.2
267
122
30.5
0.67
18
2.10
7.5
275
125
67
31.4
0.71
17
2.12
7.5
278
127
* Entering Indoor Dry Bulb Temperature
1181
63
29.4
0.87
20
2.06
7.3
263
116
59
MBh
28.8
S/T
0.93
Delta T 21
KW
2.02
AMPS 7.1
HI PR 245
LO PR 109
Airflow
65
29.9
0.63
19
2.13
7.6
281
131
32.4
0.65
19
2.18
7.8
290
135
33.4
0.69
18
2.20
7.9
293
136
30.1
0.49
15
2.11
7.5
278
129
32.6
0.50
14
2.16
7.7
287
133
71
33.6
0.53
14
2.18
7.8
290
135
25.7
0.93
24
2.11
7.5
266
112
27.8
0.96
23
2.16
7.7
274
115
28.6
1.00
22
2.18
7.8
277
116
25.2
0.88
22
2.10
7.4
264
111
27.3
0.92
22
2.15
7.6
272
114
59
28.1
0.96
21
2.16
7.7
274
115
27.4
0.81
22
2.22
7.9
303
130
29.7
0.84
22
2.27
8.1
312
134
30.6
0.88
21
2.29
8.2
315
135
27.5
0.67
19
2.20
7.8
300
128
29.8
0.70
18
2.25
8.1
309
132
67
30.7
0.73
18
2.27
8.1
312
134
29.2
0.65
19
2.29
8.2
316
138
31.7
0.68
19
2.34
8.5
325
142
32.6
0.71
18
2.36
8.5
329
144
29.4
0.50
15
2.27
8.1
312
137
31.9
0.52
15
2.32
8.4
322
141
71
32.8
0.55
14
2.34
8.5
325
142
25.0
0.95
24
2.24
8.1
303
116
27.1
0.98
23
2.29
8.4
312
120
27.9
1.00
22
2.31
8.4
315
121
24.6
0.91
22
2.22
8.1
300
115
26.7
0.94
22
2.27
8.3
309
118
59
27.5
1.00
21
2.29
8.4
312
120
25.5
0.92
23
2.28
8.3
326
123
27.7
0.95
23
2.34
8.6
336
127
28.5
1.00
22
2.36
8.7
339
129
25.1
0.85
21
2.26
8.3
323
122
27.2
0.88
21
2.32
8.5
333
126
26.7
0.83
22
2.35
8.6
344
135
29.0
0.86
22
2.41
8.9
355
139
29.8
0.90
21
2.43
8.9
358
140
26.9
0.69
19
2.33
8.5
341
133
29.1
0.72
18
2.39
8.8
351
138
28.5
0.67
19
2.43
8.9
359
144
30.9
0.70
19
2.48
9.2
370
148
31.8
0.73
18
2.50
9.3
374
149
28.7
0.52
15
2.41
8.9
355
142
31.1
0.54
15
2.47
9.1
366
147
24.4
0.98
24
2.35
8.7
345
122
26.5
1.00
23
2.40
9.0
356
126
27.3
1.00
21
2.42
9.0
359
127
24.0
0.93
22
2.33
8.6
341
121
26.0
0.97
22
2.38
8.9
352
124
24.9
0.95
24
2.40
8.9
371
130
27.0
0.98
23
2.45
9.2
383
134
27.8
1.00
22
2.47
9.3
386
135
24.5
0.88
22
2.38
8.8
367
128
26.6
0.91
21
2.43
9.1
379
132
26.1
0.85
22
2.47
9.2
392
142
28.3
0.89
22
2.53
9.5
404
146
29.1
0.93
21
2.55
9.6
408
147
28.4
0.74
18
2.51
9.4
400
145
26.2
0.71
19
2.45
9.1
388
140
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
28.1
30.0 32.1 26.8 27.4
29.3
0.92
0.75 0.56 1.00 0.95
0.78
20
18
14
21
20
18
2.34
2.41 2.48 2.40 2.45
2.53
8.6
8.9
9.2
9.0
9.2
9.5
336
355
370
356
383
404
127
139
148
126
134
146
NOTE: Shaded area is AHRI Rating Conditions
26.1
0.89
23
2.15
7.7
286
119
28.3
0.93
23
2.21
7.9
295
122
29.2
0.97
22
2.22
8.0
298
124
25.8
0.83
21
2.14
7.6
284
118
27.9
0.86
21
2.19
7.8
292
121
63
28.7
0.90
20
2.21
7.9
295
122
75
MODEL: GSX130301AA / CA*F3030*6** / ZP24K5E-PFV
27.8
0.69
19
2.55
9.6
409
151
30.1
0.72
19
2.61
9.9
421
155
31.1
0.75
18
2.63
9.9
426
157
28.0
0.53
15
2.53
9.5
405
149
30.4
0.55
15
2.59
9.8
417
154
71
31.3
0.58
14
2.61
9.9
421
155
EXPANDED PERFORMANCE DATA
23.2
1.00
23
2.44
9.3
388
128
25.1
1.00
22
2.50
9.5
400
132
25.9
1.00
20
2.52
9.6
404
133
22.8
0.97
22
2.42
9.2
384
126
24.7
1.00
22
2.48
9.5
396
130
59
25.5
1.00
20
2.50
9.5
400
132
23.7
0.98
23
2.49
9.5
417
136
25.6
1.00
22
2.55
9.8
430
140
26.4
1.00
21
2.57
9.9
435
142
23.3
0.91
21
2.47
9.4
413
135
25.3
0.94
21
2.53
9.7
426
139
63
26.0
1.00
20
2.55
9.8
430
140
24.8
0.89
22
2.57
9.8
441
148
26.8
0.92
22
2.63
10.1
455
153
27.7
0.96
21
2.65
10.2
459
154
24.9
0.74
18
2.55
9.7
437
147
27.0
0.77
18
2.61
10.0
450
151
67
27.8
0.81
17
2.63
10.1
455
153
105
26.4
0.72
19
2.65
10.2
460
158
28.6
0.75
19
2.72
10.5
474
163
29.5
0.78
18
2.74
10.6
479
165
26.6
0.55
15
2.63
10.1
455
156
28.8
0.57
14
2.70
10.4
469
161
71
29.7
0.60
14
2.72
10.5
474
163
21.5
1.00
22
2.52
9.8
429
132
23.3
1.00
20
2.58
10.1
442
136
24.0
1.00
19
2.60
10.2
446
138
21.1
0.98
21
2.50
9.7
424
131
22.9
1.00
20
2.56
10.0
438
135
59
23.6
1.00
18
2.58
10.1
442
136
21.9
0.99
22
2.57
10.1
461
141
23.7
1.00
21
2.64
10.4
476
145
24.5
1.00
19
2.66
10.5
480
146
21.6
0.92
20
2.55
10.0
457
139
23.4
0.95
19
2.62
10.3
471
143
63
24.1
1.00
19
2.64
10.4
476
145
23.0
0.89
21
2.66
10.4
487
153
24.9
0.93
20
2.72
10.7
502
158
25.6
0.97
19
2.74
10.8
507
160
23.1
0.75
17
2.63
10.3
482
152
25.0
0.77
17
2.70
10.6
497
157
67
25.7
0.81
16
2.72
10.7
502
158
115
24.5
0.72
18
2.74
10.8
508
163
26.5
0.75
17
2.81
11.1
524
168
27.3
0.79
17
2.83
11.2
529
170
24.7
0.56
14
2.72
10.7
503
162
26.7
0.58
14
2.79
11.0
519
167
71
27.5
0.61
13
2.81
11.1
524
168
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130301A*
17
18
75
70
IDB*
34.5
0.58
15
2.48
9.0
249
111
31.9
0.56
15
2.43
8.7
242
108
35.9
0.74
18
2.52
9.1
254
114
34.9
0.70
19
2.50
9.0
252
112
32.2
0.68
19
2.45
8.8
244
109
MBh
33.3
S/T
0.69
Delta T 18
KW
2.43
AMPS 8.7
HI PR 231
LO PR 105
MBh
30.7
S/T
0.67
Delta T 18
KW
2.38
AMPS 8.5
HI PR 224
LO PR 101
MBh
34.9
S/T
0.82
Delta T 20
KW
2.47
AMPS 8.9
HI PR 236
LO PR 107
MBh
33.9
S/T
0.78
Delta T 20
KW
2.45
AMPS 8.8
HI PR 234
LO PR 106
MBh
31.3
S/T
0.76
Delta T 21
KW
2.40
AMPS 8.6
HI PR 227
LO PR 103
1200
1050
1350
1200
1050
67
34.8
0.51
16
2.52
9.1
258
119
37.7
0.53
15
2.58
9.3
266
123
38.9
0.56
15
2.60
9.4
268
124
34.9
0.38
12
2.50
9.0
255
118
37.8
0.40
12
2.56
9.3
263
122
38.9
0.42
11
2.58
9.3
266
123
* Entering Indoor Dry Bulb Temperature
1350
63
35.5
0.60
15
2.50
9.0
252
112
59
MBh
34.3
S/T
0.72
Delta T 17
KW
2.45
AMPS 8.8
HI PR 234
LO PR 106
Airflow
65
37.4
0.33
11
2.60
9.4
269
127
40.5
0.34
11
2.66
9.7
277
131
41.7
0.36
10
2.68
9.8
280
132
-
-
-
71
59
30.5
0.78
21
2.57
9.3
254
108
33.1
0.81
21
2.63
9.6
262
112
34.1
0.85
20
2.66
9.6
265
113
30.0
0.69
18
2.55
9.2
252
107
32.5
0.71
18
2.61
9.5
260
111
33.5
0.75
17
2.63
9.6
262
112
63
67
34.0
0.53
16
2.71
9.8
289
126
36.9
0.55
16
2.77
10.1
298
130
38.0
0.58
15
2.79
10.2
301
131
34.1
0.40
12
2.69
9.7
286
125
36.9
0.41
12
2.75
10.0
295
128
38.0
0.43
11
2.77
10.1
298
130
36.5
0.34
11
2.79
10.2
302
134
39.6
0.35
11
2.86
10.5
311
138
40.7
0.37
10
2.88
10.6
314
139
-
-
-
71
59
29.8
0.80
21
2.73
10.1
289
113
32.3
0.83
21
2.79
10.4
298
116
33.3
0.87
20
2.82
10.5
301
117
29.3
0.71
18
2.71
10.0
286
111
31.7
0.73
18
2.77
10.3
295
115
32.7
0.77
17
2.79
10.4
298
116
30.7
0.72
19
2.79
10.4
311
120
33.2
0.75
19
2.85
10.7
321
123
34.2
0.78
18
2.88
10.8
324
125
30.4
0.59
16
2.76
10.3
308
119
32.9
0.61
15
2.83
10.6
318
122
33.9
0.64
15
2.85
10.7
321
123
33.2
0.54
16
2.87
10.7
329
131
36.0
0.56
16
2.94
11.0
339
135
37.1
0.59
15
2.97
11.1
342
136
33.3
0.41
12
2.85
10.6
326
129
36.1
0.42
12
2.92
10.9
336
133
37.1
0.44
11
2.94
11.0
339
135
35.6
0.35
11
2.96
11.1
343
139
38.6
0.36
11
3.04
11.5
354
144
39.8
0.38
10
3.06
11.6
357
145
-
-
-
29.1
0.83
21
2.87
10.8
330
118
31.5
0.86
21
2.94
11.1
340
122
32.4
0.90
20
2.96
11.3
343
123
28.6
0.73
18
2.84
10.7
326
117
31.0
0.76
18
2.91
11.0
336
121
31.9
0.79
17
2.94
11.1
340
122
29.9
0.74
19
2.93
11.1
355
126
32.4
0.77
19
3.00
11.4
366
130
33.4
0.81
18
3.02
11.5
369
131
29.6
0.61
16
2.90
11.0
351
125
32.1
0.63
16
2.97
11.3
362
128
33.1
0.66
15
3.00
11.4
366
130
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
NOTE: Shaded area is ACCA (TVA) conditions
31.4
0.70
19
2.63
9.5
274
115
34.1
0.73
19
2.69
9.8
282
119
35.1
0.76
18
2.71
9.9
285
120
31.1
0.58
16
2.61
9.4
271
114
33.7
0.60
15
2.67
9.7
279
118
34.7
0.63
15
2.69
9.8
282
119
75
MODEL: GSX130361A* / CA*F4860*6** / ZP31K5E-PFV
32.4
0.56
16
3.02
11.5
375
137
35.1
0.58
16
3.09
11.8
386
142
36.2
0.61
15
3.12
11.9
390
143
32.5
0.42
12
2.99
11.4
371
136
35.2
0.44
12
3.07
11.7
382
140
36.2
0.46
11
3.09
11.8
386
142
67
34.8
0.36
11
3.12
11.9
391
146
37.7
0.37
11
3.20
12.3
403
151
38.8
0.39
10
3.22
12.4
407
152
-
-
-
71
EXPANDED PERFORMANCE DATA
59
27.6
0.86
21
2.98
11.5
371
124
29.9
0.89
20
3.06
11.9
382
128
30.8
0.94
20
3.08
12.0
386
129
27.2
0.76
18
2.96
11.4
367
123
29.4
0.79
18
3.03
11.8
378
126
30.3
0.82
17
3.06
11.9
382
128
63
28.4
0.77
19
3.05
11.8
399
132
30.8
0.80
19
3.12
12.2
411
136
31.7
0.84
18
3.15
12.3
415
137
28.2
0.63
16
3.02
11.7
395
130
30.5
0.66
15
3.10
12.1
407
135
31.4
0.69
15
3.12
12.2
411
136
67
30.8
0.58
16
3.14
12.2
421
144
33.3
0.60
15
3.22
12.6
434
148
34.4
0.63
15
3.25
12.7
439
150
30.8
0.44
12
3.12
12.1
417
142
33.4
0.45
12
3.20
12.5
430
147
34.4
0.48
11
3.22
12.6
434
148
105
33.0
0.37
11
3.25
12.7
439
153
35.8
0.39
11
3.33
13.1
453
158
36.9
0.41
10
3.36
13.2
458
160
-
-
-
71
59
25.6
0.87
19
3.08
12.2
410
128
27.7
0.90
19
3.16
12.6
422
132
28.6
0.94
18
3.19
12.7
427
133
25.2
0.76
17
3.06
12.1
406
127
27.3
0.79
17
3.13
12.5
418
131
28.1
0.83
16
3.16
12.6
422
132
63
26.3
0.78
18
3.15
12.6
441
136
28.5
0.81
18
3.23
12.9
454
141
29.4
0.84
17
3.26
13.0
459
142
26.1
0.64
15
3.12
12.4
436
135
28.3
0.66
14
3.20
12.8
450
139
29.1
0.69
14
3.23
12.9
454
141
67
28.5
0.59
15
3.25
13.0
466
149
30.9
0.61
14
3.33
13.4
480
153
31.8
0.64
14
3.36
13.5
485
155
28.6
0.44
11
3.22
12.9
461
147
31.0
0.46
11
3.31
13.2
475
152
31.9
0.48
10
3.33
13.4
480
153
115
30.6
0.38
10
3.36
13.5
486
159
33.2
0.39
10
3.44
13.9
501
163
34.2
0.41
10
3.47
14.0
506
165
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130361A*
85
80
IDB*
34.5
0.86
23
2.47
8.9
236
107
31.8
0.83
23
2.42
8.7
229
104
36.1
0.95
23
2.51
9.1
241
109
35.1
0.90
24
2.49
9.0
238
108
32.4
0.87
25
2.43
8.7
231
105
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1200
1050
1350
1200
1050
33.0
0.84
24
2.48
9.0
249
111
35.7
0.87
24
2.54
9.2
257
115
36.8
0.91
23
2.56
9.3
259
116
32.5
0.78
22
2.46
8.9
246
110
35.2
0.81
22
2.52
9.1
254
114
63
36.3
0.85
21
2.54
9.2
257
115
34.6
0.76
23
2.56
9.3
263
121
37.4
0.79
23
2.62
9.5
271
125
38.6
0.82
22
2.64
9.6
274
126
34.7
0.63
19
2.54
9.2
260
120
37.6
0.66
19
2.60
9.4
268
124
67
38.8
0.69
18
2.62
9.5
271
125
* Entering Indoor Dry Bulb Temperature
1350
59
35.5
0.90
22
2.49
9.0
238
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
36.9
0.61
20
2.64
9.6
274
129
39.9
0.64
19
2.70
9.9
283
133
41.1
0.67
19
2.72
10.0
285
135
37.1
0.47
15
2.62
9.5
271
128
40.2
0.49
15
2.68
9.8
280
132
71
41.4
0.51
15
2.70
9.9
283
133
31.6
0.90
25
2.61
9.5
260
110
34.3
0.93
25
2.68
9.7
268
114
35.3
0.98
24
2.70
9.8
270
115
31.1
0.86
23
2.59
9.4
257
109
33.7
0.89
23
2.66
9.6
265
113
59
34.7
0.93
22
2.68
9.7
268
114
33.8
0.78
23
2.75
10.0
295
128
36.6
0.81
23
2.82
10.3
304
132
37.7
0.85
22
2.84
10.4
307
134
33.9
0.66
19
2.73
9.9
292
127
36.8
0.68
19
2.79
10.2
301
131
67
37.9
0.71
18
2.82
10.3
304
132
36.0
0.64
20
2.84
10.4
308
137
39.0
0.66
20
2.91
10.7
317
141
40.2
0.69
19
2.93
10.8
320
142
36.3
0.49
16
2.81
10.3
305
135
39.3
0.51
15
2.88
10.6
314
140
71
40.5
0.53
15
2.91
10.7
317
141
30.9
0.92
25
2.77
10.3
295
115
33.4
0.96
25
2.84
10.6
304
118
34.4
1.00
23
2.86
10.7
307
120
30.3
0.88
23
2.75
10.2
292
114
32.9
0.91
23
2.82
10.5
301
117
59
33.8
0.96
22
2.84
10.6
304
118
31.5
0.89
25
2.83
10.6
318
122
34.1
0.92
24
2.90
10.9
328
126
35.1
0.97
23
2.92
11.0
331
127
31.0
0.83
22
2.81
10.5
315
121
33.6
0.86
22
2.88
10.8
324
125
32.9
0.80
23
2.92
10.9
335
133
35.7
0.83
23
2.99
11.2
346
137
36.8
0.87
22
3.02
11.4
349
139
33.1
0.67
20
2.90
10.8
332
132
35.9
0.70
19
2.97
11.1
342
136
35.1
0.65
20
3.01
11.3
350
142
38.1
0.68
20
3.09
11.7
361
146
39.2
0.71
19
3.11
11.8
364
148
35.4
0.50
16
2.99
11.2
346
141
38.4
0.52
15
3.06
11.6
357
145
30.1
0.95
25
2.91
11.0
336
121
32.6
0.99
25
2.98
11.4
347
124
33.6
1.00
23
3.01
11.5
350
126
29.6
0.91
24
2.89
10.9
333
119
32.1
0.94
23
2.96
11.3
343
123
30.7
0.92
25
2.97
11.3
362
128
33.3
0.95
24
3.05
11.6
373
132
34.2
1.00
23
3.07
11.8
377
134
30.2
0.85
23
2.95
11.2
358
127
32.8
0.88
22
3.02
11.5
369
131
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
34.6
37.0 39.5 33.0
33.7
0.90
0.73 0.55 1.00
0.93
21
18
15
22
21
2.90
2.99 3.09 2.98
3.05
10.9
11.2 11.7 11.4
11.6
328
346
361
347
373
126
137
146
124
132
NOTE: Shaded area is AHRI Rating Conditions
32.2
0.87
25
2.67
9.7
279
118
34.9
0.90
24
2.73
10.0
288
121
36.0
0.95
23
2.75
10.1
291
122
31.7
0.81
22
2.65
9.6
277
116
34.4
0.84
22
2.71
9.9
285
120
63
35.4
0.88
21
2.73
10.0
288
121
75
MODEL: GSX130361AA / CA*F4860*6** / ZP31K5E-PFV
32.1
0.83
23
3.07
11.7
382
140
34.8
0.86
23
3.15
12.0
394
144
35.9
0.90
22
3.17
12.2
398
146
35.0
0.72
19
3.12
11.9
390
143
32.3
0.69
20
3.04
11.6
378
139
67
36.1
0.75
19
3.15
12.0
394
144
34.3
0.67
20
3.17
12.2
399
149
37.2
0.70
20
3.25
12.5
411
154
38.3
0.73
19
3.27
12.6
415
155
34.5
0.52
16
3.14
12.0
395
148
37.4
0.54
15
3.22
12.4
407
152
71
38.5
0.56
15
3.25
12.5
411
154
EXPANDED PERFORMANCE DATA
28.6
0.99
25
3.03
11.8
378
126
31.0
1.00
24
3.11
12.1
390
130
31.9
1.00
22
3.13
12.2
394
132
28.1
0.94
23
3.01
11.7
375
125
30.5
0.98
23
3.08
12.0
386
129
59
31.4
1.00
21
3.11
12.1
390
130
29.2
0.95
24
3.10
12.1
407
134
31.6
0.99
24
3.17
12.4
420
139
32.5
1.00
22
3.20
12.5
424
140
28.7
0.89
22
3.07
11.9
403
133
31.1
0.92
22
3.15
12.3
415
137
63
32.1
0.96
21
3.17
12.4
420
139
30.5
0.86
23
3.20
12.5
430
147
33.1
0.89
23
3.28
12.8
443
151
34.1
0.94
22
3.30
13.0
448
153
30.7
0.72
19
3.17
12.4
426
145
33.3
0.75
19
3.25
12.7
439
150
67
34.2
0.78
18
3.28
12.8
443
151
105
32.6
0.70
20
3.30
13.0
448
156
35.3
0.73
20
3.38
13.3
462
161
36.4
0.76
19
3.41
13.5
467
163
32.8
0.54
15
3.27
12.8
444
155
35.5
0.56
15
3.36
13.2
458
160
71
36.6
0.59
15
3.38
13.3
462
161
26.5
1.00
23
3.13
12.5
418
131
28.7
1.00
22
3.21
12.8
431
135
29.6
1.00
20
3.24
13.0
435
136
26.0
0.95
22
3.11
12.4
414
129
28.2
0.99
21
3.19
12.7
427
133
59
29.1
1.00
20
3.21
12.8
431
135
27.0
0.96
23
3.20
12.8
450
139
29.3
1.00
22
3.28
13.2
464
143
30.1
1.00
21
3.31
13.3
468
145
26.6
0.89
21
3.18
12.7
445
138
28.8
0.93
20
3.26
13.1
459
142
63
29.7
0.97
20
3.28
13.2
464
143
28.3
0.87
22
3.30
13.2
475
152
30.6
0.90
21
3.39
13.6
490
157
31.6
0.94
20
3.42
13.8
495
158
28.4
0.73
18
3.28
13.1
470
150
30.8
0.75
18
3.36
13.5
485
155
67
31.7
0.79
17
3.39
13.6
490
157
115
30.2
0.71
19
3.41
13.8
495
162
32.7
0.73
18
3.50
14.2
511
167
33.7
0.77
18
3.53
14.3
516
168
30.4
0.54
14
3.39
13.6
490
160
32.9
0.56
14
3.47
14.0
506
165
71
33.9
0.59
14
3.50
14.2
511
167
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130361A*
19
20
75
70
IDB*
38.1
0.70
17
2.81
10.0
233
106
35.1
0.67
18
2.75
9.7
226
103
39.9
0.83
19
2.85
10.2
238
108
38.7
0.79
20
2.83
10.1
236
107
35.7
0.77
21
2.77
9.8
228
104
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1400
1225
1575
1400
1225
63
36.8
0.69
19
2.82
10.1
246
111
39.8
0.71
19
2.89
10.4
253
114
41.0
0.75
18
2.91
10.5
256
115
36.4
0.56
15
2.80
10.0
243
109
39.4
0.58
15
2.87
10.3
251
113
40.6
0.61
15
2.89
10.4
253
114
67
39.8
0.52
16
2.91
10.4
260
121
43.1
0.54
15
2.97
10.7
268
124
44.4
0.56
15
3.00
10.8
270
126
39.9
0.39
12
2.88
10.3
257
120
43.2
0.40
11
2.95
10.6
265
123
44.5
0.42
11
2.97
10.7
268
124
* Entering Indoor Dry Bulb Temperature
1575
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
59
39.2
0.73
17
2.83
10.1
236
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
42.7
0.33
11
2.99
10.8
271
129
46.3
0.35
11
3.06
11.2
279
133
47.7
0.36
10
3.09
11.3
282
134
-
-
-
71
59
34.9
0.79
21
2.97
10.7
256
110
37.8
0.82
20
3.04
11.0
264
113
38.9
0.86
20
3.06
11.1
267
114
34.3
0.70
18
2.94
10.6
254
109
37.2
0.72
18
3.01
10.9
262
112
38.3
0.76
17
3.03
11.0
264
113
63
67
38.9
0.54
16
3.12
11.3
291
128
42.1
0.56
15
3.19
11.7
300
131
43.4
0.58
15
3.21
11.8
303
133
39.0
0.40
12
3.09
11.2
288
126
42.2
0.42
12
3.17
11.5
297
130
43.5
0.44
11
3.19
11.7
300
131
41.7
0.35
11
3.21
11.8
304
136
45.2
0.36
11
3.29
12.1
313
140
46.6
0.38
10
3.31
12.2
316
141
-
-
-
71
59
34.1
0.81
21
3.14
11.6
292
114
36.9
0.84
20
3.22
12.0
301
118
38.0
0.89
20
3.24
12.1
304
119
33.5
0.72
18
3.12
11.5
289
113
36.3
0.74
18
3.19
11.9
298
116
37.4
0.78
17
3.21
12.0
301
118
35.1
0.73
19
3.20
11.9
314
121
38.0
0.76
19
3.28
12.3
323
125
39.1
0.79
18
3.31
12.4
327
126
34.7
0.60
16
3.18
11.8
311
120
37.6
0.62
15
3.26
12.2
320
124
38.7
0.65
15
3.28
12.3
323
125
38.0
0.55
16
3.30
12.4
331
133
41.1
0.57
15
3.38
12.7
342
137
42.4
0.60
15
3.41
12.8
345
138
38.0
0.41
12
3.28
12.2
328
131
41.2
0.43
12
3.36
12.6
338
135
42.4
0.45
11
3.38
12.7
342
137
40.7
0.35
11
3.41
12.8
346
141
44.1
0.37
11
3.49
13.2
356
146
45.5
0.39
10
3.52
13.3
360
147
-
-
-
33.2
0.84
21
3.29
12.5
332
120
36.0
0.87
21
3.37
12.9
342
124
37.1
0.91
20
3.40
13.0
346
125
32.7
0.74
18
3.27
12.4
329
119
35.4
0.77
18
3.35
12.7
339
122
36.5
0.80
17
3.37
12.8
342
124
37.1
0.43
12
3.44
13.1
374
138
41.3
0.62
15
3.58
13.8
393
145
40.1
0.59
16
3.55
13.6
389
144
37.0
0.57
16
3.47
13.2
377
139
38.2
0.82
18
3.47
13.3
372
133
37.1
0.78
19
3.44
13.2
368
131
34.2
0.75
19
3.36
12.8
357
128
40.2
0.44
12
3.52
13.5
385
142
41.4
0.47
11
3.55
13.6
389
144
33.9
0.62
16
3.34
12.7
354
126
36.7
0.64
15
3.42
13.1
365
130
37.8
0.67
15
3.44
13.2
368
131
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
NOTE: Shaded area is ACCA (TVA) conditions
35.9
0.71
19
3.03
10.9
276
117
38.9
0.74
19
3.10
11.3
284
120
40.1
0.77
18
3.12
11.4
287
122
35.6
0.58
16
3.00
10.8
273
116
38.5
0.61
15
3.07
11.2
282
119
39.7
0.63
15
3.10
11.3
284
120
75
MODEL: GSX130421A* / CA*F4860*6** / ZP34K5-PFV
39.7
0.37
11
3.58
13.8
394
148
43.1
0.38
11
3.66
14.2
406
153
44.4
0.40
10
3.69
14.3
410
154
-
-
-
71
EXPANDED PERFORMANCE DATA
59
31.6
0.87
21
3.43
13.3
374
126
34.2
0.90
20
3.51
13.7
385
130
35.2
0.95
20
3.54
13.8
389
131
31.0
0.77
18
3.40
13.2
370
124
33.6
0.80
18
3.48
13.6
381
128
34.6
0.83
17
3.51
13.7
385
130
63
32.5
0.78
19
3.50
13.7
402
134
35.2
0.81
19
3.58
14.1
415
138
36.3
0.85
18
3.61
14.2
419
139
32.2
0.64
15
3.47
13.5
398
132
34.9
0.66
15
3.55
13.9
410
136
35.9
0.70
15
3.58
14.1
414
138
67
35.2
0.59
16
3.61
14.1
425
146
38.1
0.61
15
3.70
14.6
438
150
39.3
0.64
15
3.73
14.7
442
152
35.2
0.44
12
3.58
14.0
420
144
38.2
0.46
12
3.67
14.4
433
149
39.3
0.48
11
3.69
14.6
438
150
105
37.8
0.38
11
3.72
14.7
443
155
40.9
0.39
11
3.81
15.1
457
160
42.1
0.41
10
3.84
15.3
461
162
-
-
-
71
59
29.2
0.88
19
3.54
14.1
413
130
31.7
0.91
19
3.62
14.6
426
134
32.6
0.96
18
3.65
14.7
430
135
28.8
0.77
17
3.51
14.0
409
129
31.2
0.80
16
3.60
14.4
421
133
32.1
0.84
16
3.62
14.6
425
134
63
30.1
0.79
18
3.61
14.5
444
138
32.6
0.82
17
3.70
14.9
458
143
33.6
0.86
17
3.73
15.1
463
144
29.8
0.65
14
3.58
14.4
440
137
32.3
0.67
14
3.67
14.8
453
141
33.3
0.70
14
3.70
14.9
458
143
67
32.6
0.60
15
3.73
15.0
469
151
35.3
0.62
14
3.82
15.5
484
156
36.4
0.65
14
3.85
15.6
488
157
32.7
0.45
11
3.70
14.9
464
149
35.4
0.46
11
3.79
15.3
479
154
36.4
0.49
10
3.82
15.5
484
156
115
35.0
0.38
10
3.85
15.6
489
161
37.9
0.40
10
3.94
16.1
504
166
39.0
0.42
9
3.98
16.2
509
167
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130421A*
85
80
IDB*
39.4
0.87
23
2.85
10.2
238
108
36.4
0.84
23
2.79
9.9
231
105
41.3
0.96
23
2.90
10.4
243
110
40.1
0.91
24
2.87
10.3
240
109
37.0
0.88
24
2.81
10.0
233
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1400
1225
1575
1400
1225
37.7
0.85
24
2.87
10.3
251
113
40.9
0.88
24
2.93
10.6
259
116
42.1
0.92
23
2.95
10.7
261
117
37.1
0.79
22
2.84
10.2
248
112
40.2
0.82
22
2.91
10.5
256
115
63
41.5
0.86
21
2.93
10.6
259
116
39.5
0.77
23
2.95
10.6
265
123
42.8
0.80
22
3.02
10.9
273
127
44.1
0.83
21
3.04
11.0
276
128
39.7
0.64
19
2.93
10.5
262
122
43.0
0.67
19
3.00
10.8
270
126
67
44.3
0.70
18
3.02
10.9
273
127
* Entering Indoor Dry Bulb Temperature
1575
59
40.6
0.91
22
2.87
10.3
240
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
42.1
0.62
20
3.04
11.0
276
131
45.6
0.65
19
3.11
11.4
285
135
47.0
0.68
19
3.13
11.5
288
137
42.4
0.48
15
3.02
10.9
274
130
46.0
0.50
15
3.09
11.3
282
134
71
47.3
0.52
14
3.11
11.4
285
135
36.1
0.91
25
3.01
10.9
262
112
39.1
0.95
24
3.08
11.2
270
116
40.3
0.99
23
3.11
11.3
272
117
35.5
0.87
23
2.99
10.8
259
111
38.5
0.90
23
3.06
11.1
267
114
59
39.6
0.95
22
3.08
11.2
270
116
38.6
0.80
23
3.16
11.5
297
130
41.8
0.82
23
3.24
11.9
306
134
43.0
0.86
22
3.27
12.0
309
135
38.8
0.67
19
3.14
11.4
294
129
42.0
0.69
19
3.22
11.8
303
133
67
43.3
0.72
18
3.24
11.9
306
134
41.2
0.65
20
3.26
12.0
310
139
44.6
0.67
20
3.34
12.3
320
143
45.9
0.70
19
3.37
12.5
323
144
41.4
0.50
15
3.24
11.9
307
137
44.9
0.52
15
3.31
12.2
316
141
71
46.2
0.54
15
3.34
12.3
320
143
35.3
0.94
25
3.19
11.9
297
116
38.2
0.97
24
3.27
12.2
307
120
39.4
1.00
23
3.29
12.3
310
121
34.7
0.89
23
3.16
11.8
295
115
37.6
0.93
23
3.24
12.1
304
119
59
38.7
1.00
23
3.27
12.2
307
120
36.0
0.90
24
3.25
12.2
320
124
39.0
0.94
24
3.33
12.5
330
128
40.1
0.98
23
3.36
12.7
333
129
35.4
0.84
22
3.23
12.1
317
123
38.4
0.87
22
3.31
12.4
327
126
37.7
0.82
23
3.35
12.6
338
135
40.8
0.85
23
3.44
13.0
349
139
42.0
0.89
22
3.46
13.1
352
141
37.8
0.68
19
3.33
12.5
335
134
41.0
0.71
19
3.41
12.8
345
138
40.2
0.66
20
3.46
13.1
353
144
43.5
0.69
20
3.54
13.5
363
148
44.8
0.72
19
3.57
13.6
367
150
40.5
0.51
15
3.43
13.0
349
143
43.8
0.53
15
3.52
13.3
360
147
34.4
0.97
25
3.35
12.7
339
122
37.3
1.00
24
3.43
13.1
349
126
38.4
1.00
22
3.45
13.2
353
127
33.8
0.92
23
3.32
12.6
335
121
36.6
0.96
23
3.40
13.0
346
125
35.1
0.93
25
3.42
13.0
365
130
38.0
0.97
24
3.50
13.4
376
134
39.1
1.00
23
3.53
13.6
380
135
34.6
0.86
22
3.39
12.9
361
129
37.4
0.90
22
3.47
13.3
372
133
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
39.5
42.2 45.1 37.7
38.6
0.91
0.74 0.55 1.00
0.94
21
18
15
22
21
3.33
3.44 3.54 3.43
3.50
12.5
13.0 13.5 13.1
13.4
330
349
363
349
376
128
139
148
126
134
NOTE: Shaded area is AHRI Rating Conditions
36.8
0.88
24
3.07
11.2
281
119
39.9
0.91
24
3.14
11.5
290
123
41.1
0.96
23
3.17
11.6
293
124
36.3
0.82
22
3.05
11.0
279
118
39.3
0.85
22
3.12
11.4
287
122
63
40.5
0.89
21
3.14
11.5
290
123
75
MODEL: GSX130421AA / CA*F4860*6** / ZP34K5-PFV
36.7
0.84
23
3.52
13.5
385
142
39.8
0.87
23
3.61
13.9
397
146
41.0
0.92
22
3.64
14.0
401
148
40.0
0.73
19
3.58
13.8
393
145
36.9
0.70
20
3.49
13.4
381
141
67
41.2
0.77
18
3.61
13.9
397
146
39.2
0.68
20
3.63
14.0
402
151
42.5
0.71
20
3.72
14.5
414
156
43.7
0.74
19
3.75
14.6
418
158
39.5
0.53
16
3.61
13.9
398
150
42.8
0.55
15
3.69
14.3
410
154
71
44.0
0.57
15
3.72
14.5
414
156
EXPANDED PERFORMANCE DATA
32.7
1.00
25
3.48
13.6
381
128
35.4
1.00
23
3.56
14.0
393
132
36.5
1.00
21
3.59
14.1
397
133
32.1
0.96
23
3.45
13.4
377
127
34.8
0.99
23
3.54
13.8
389
131
59
35.9
1.00
21
3.56
14.0
393
132
33.3
0.97
24
3.55
13.9
410
136
36.1
1.00
24
3.64
14.3
423
141
37.2
1.00
22
3.67
14.5
427
142
32.8
0.90
22
3.53
13.8
406
135
35.6
0.93
22
3.61
14.2
419
139
63
36.6
1.00
21
3.64
14.3
423
141
34.9
0.87
23
3.66
14.4
433
149
37.8
0.91
22
3.76
14.8
447
153
38.9
0.95
22
3.79
15.0
451
155
35.1
0.73
19
3.64
14.3
429
147
38.0
0.76
19
3.73
14.7
442
152
67
39.1
0.79
18
3.76
14.8
447
153
105
37.2
0.71
20
3.78
15.0
452
159
40.3
0.74
19
3.88
15.4
466
163
41.5
0.77
19
3.91
15.6
470
165
37.5
0.55
15
3.75
14.8
447
157
40.6
0.57
15
3.85
15.3
461
162
71
41.8
0.59
15
3.88
15.4
466
163
30.3
1.00
23
3.59
14.4
421
133
32.8
1.00
22
3.68
14.8
434
137
33.8
1.00
20
3.71
15.0
439
138
29.8
0.97
22
3.57
14.3
417
131
32.2
1.00
21
3.65
14.7
430
135
59
33.2
1.00
19
3.68
14.8
434
137
30.9
0.98
23
3.67
14.8
453
141
33.4
1.00
22
3.76
15.2
467
145
34.4
1.00
20
3.79
15.4
472
147
30.4
0.91
21
3.64
14.6
449
140
32.9
0.94
20
3.73
15.1
463
144
63
33.9
1.00
20
3.76
15.2
467
145
32.3
0.88
21
3.79
15.3
479
154
35.0
0.91
21
3.88
15.8
493
159
36.1
0.96
20
3.91
15.9
498
160
32.5
0.74
18
3.76
15.2
474
152
35.2
0.76
18
3.85
15.6
488
157
67
36.3
0.80
17
3.88
15.8
493
159
115
34.5
0.71
19
3.91
15.9
499
164
37.4
0.74
18
4.01
16.4
515
169
38.5
0.78
17
4.04
16.5
520
171
34.7
0.55
14
3.88
15.8
494
162
37.6
0.57
14
3.98
16.2
510
167
71
38.8
0.60
14
4.01
16.4
515
169
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130421A*
21
22
75
70
IDB*
43.8
0.72
18
3.13
11.5
233
109
40.4
0.69
18
3.05
11.2
226
106
45.8
0.86
20
3.18
11.7
238
111
44.5
0.82
21
3.16
11.6
236
110
41.1
0.79
21
3.08
11.3
228
107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1600
1400
1800
1600
1400
63
42.3
0.70
20
3.15
11.5
246
114
45.8
0.73
19
3.22
11.9
253
117
47.2
0.77
18
3.25
12.0
256
118
41.9
0.58
16
3.12
11.4
243
112
45.4
0.60
16
3.20
11.8
251
116
46.7
0.63
15
3.22
11.9
253
117
67
45.8
0.53
16
3.25
11.9
260
124
49.6
0.55
16
3.33
12.3
268
128
51.1
0.58
15
3.36
12.4
270
129
45.9
0.40
12
3.22
11.8
257
123
49.7
0.42
12
3.30
12.1
265
127
51.2
0.44
11
3.33
12.3
268
128
* Entering Indoor Dry Bulb Temperature
1800
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
59
45.1
0.75
17
3.16
11.6
236
110
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
49.1
0.34
11
3.35
12.4
271
132
53.2
0.36
11
3.44
12.7
279
136
54.8
0.37
10
3.47
12.9
282
138
-
-
-
71
59
40.1
0.82
22
3.32
12.2
256
113
43.5
0.85
21
3.40
12.5
264
116
44.8
0.89
20
3.43
12.7
267
118
39.5
0.72
19
3.29
12.1
254
112
42.7
0.74
18
3.38
12.4
262
115
44.0
0.78
18
3.40
12.5
264
116
63
67
44.7
0.55
16
3.50
12.9
291
131
48.4
0.57
16
3.59
13.3
300
135
49.9
0.60
15
3.62
13.4
303
136
44.8
0.42
12
3.47
12.8
288
130
48.5
0.43
12
3.56
13.2
297
134
50.0
0.45
12
3.59
13.3
300
135
48.0
0.36
11
3.62
13.4
304
140
52.0
0.37
11
3.71
13.8
313
144
53.6
0.39
11
3.75
13.9
316
145
-
-
-
71
59
39.2
0.84
22
3.53
13.3
292
117
42.4
0.87
21
3.62
13.7
301
121
43.7
0.91
20
3.65
13.8
304
122
38.5
0.74
19
3.50
13.1
289
116
41.7
0.76
18
3.59
13.5
298
120
43.0
0.80
18
3.62
13.7
301
121
40.3
0.75
20
3.61
13.6
314
125
43.7
0.78
19
3.71
14.0
323
129
45.0
0.81
19
3.74
14.1
327
130
39.9
0.61
16
3.58
13.5
311
124
43.2
0.64
16
3.67
13.9
320
127
44.5
0.67
15
3.70
14.0
323
129
43.7
0.57
16
3.73
14.1
331
136
47.3
0.59
16
3.83
14.5
342
140
48.7
0.62
15
3.86
14.6
345
142
43.7
0.43
12
3.70
13.9
328
135
47.4
0.44
12
3.80
14.3
338
139
48.8
0.46
12
3.83
14.5
342
140
46.8
0.36
11
3.86
14.6
346
145
50.8
0.38
11
3.96
15.0
356
150
52.3
0.40
11
3.99
15.2
360
151
-
-
-
38.2
0.86
22
3.72
14.2
332
123
41.4
0.90
21
3.82
14.6
342
127
42.6
0.94
20
3.85
14.8
346
128
37.6
0.76
19
3.69
14.1
329
122
40.7
0.79
18
3.79
14.5
339
126
41.9
0.83
18
3.82
14.6
342
127
39.3
0.77
20
3.80
14.6
357
131
42.6
0.80
20
3.90
15.0
368
135
43.9
0.84
19
3.94
15.1
372
136
38.9
0.63
16
3.77
14.4
354
130
42.2
0.66
16
3.87
14.8
365
134
43.5
0.69
15
3.90
15.0
368
135
42.6
0.58
16
3.93
15.1
377
143
46.1
0.61
16
4.04
15.5
389
148
47.5
0.64
15
4.07
15.6
393
149
42.7
0.44
12
3.90
14.9
374
142
46.2
0.46
12
4.00
15.4
385
146
47.6
0.48
12
4.03
15.5
389
147
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
NOTE: Shaded area is ACCA (TVA) conditions
41.3
0.73
20
3.39
12.5
276
120
44.8
0.76
19
3.48
12.9
284
124
46.1
0.79
19
3.51
13.0
287
125
40.9
0.60
16
3.37
12.4
273
119
44.3
0.62
16
3.45
12.7
282
123
45.6
0.65
15
3.48
12.9
284
124
75
MODEL: GSX13048-1A* / CA*F4860*6** / ZP39K5E-PFV
45.7
0.38
11
4.07
15.6
394
152
49.5
0.39
11
4.17
16.1
406
157
51.0
0.41
11
4.21
16.3
410
159
-
-
-
71
EXPANDED PERFORMANCE DATA
59
36.3
0.90
21
3.88
15.1
374
129
39.3
0.93
21
3.98
15.6
385
133
40.5
0.97
20
4.02
15.7
389
134
35.7
0.79
18
3.85
15.0
370
128
38.7
0.82
18
3.95
15.4
381
132
39.8
0.86
17
3.98
15.6
385
133
63
37.4
0.80
20
3.97
15.5
402
137
40.5
0.83
19
4.07
16.0
415
142
41.7
0.87
19
4.11
16.1
419
143
37.0
0.66
16
3.93
15.4
398
136
40.1
0.68
16
4.04
15.8
410
140
41.3
0.72
15
4.07
16.0
414
142
67
40.5
0.61
16
4.10
16.1
425
150
43.8
0.63
16
4.21
16.5
438
155
45.1
0.66
15
4.25
16.7
442
156
40.5
0.46
12
4.07
15.9
420
148
43.9
0.47
12
4.17
16.4
433
153
45.2
0.50
11
4.21
16.5
438
155
105
43.4
0.39
11
4.24
16.7
443
160
47.0
0.40
11
4.36
17.2
457
165
48.5
0.42
11
4.39
17.3
461
166
-
-
-
71
59
33.6
0.90
20
4.02
16.1
413
134
36.4
0.94
20
4.12
16.5
426
138
37.5
0.98
19
4.16
16.7
430
139
33.1
0.80
17
3.98
15.9
409
132
35.8
0.82
17
4.09
16.4
421
136
36.9
0.86
16
4.12
16.5
425
138
63
34.6
0.81
18
4.11
16.5
444
142
37.5
0.84
18
4.22
17.0
458
146
38.6
0.88
17
4.26
17.1
463
148
34.3
0.66
15
4.07
16.3
440
141
37.1
0.69
15
4.18
16.8
453
145
38.2
0.72
14
4.22
17.0
458
146
67
37.5
0.61
15
4.25
17.0
469
155
40.6
0.63
15
4.36
17.5
484
160
41.8
0.67
14
4.40
17.7
488
161
37.5
0.46
11
4.21
16.9
464
154
40.7
0.48
11
4.32
17.4
479
158
41.9
0.50
11
4.36
17.5
484
160
115
40.2
0.39
10
4.40
17.7
489
165
43.6
0.41
10
4.51
18.2
504
170
44.9
0.43
10
4.55
18.4
509
172
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130481A*
85
80
IDB*
41.8
0.86
24
3.10
11.4
231
108
47.5
0.98
24
3.23
11.9
243
113
46.1
0.94
25
3.21
11.8
240
112
42.5
0.91
25
3.13
11.5
233
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1400
1800
1600
1400
43.4
0.87
25
3.20
11.7
251
116
47.0
0.91
24
3.28
12.1
259
120
48.4
0.95
23
3.30
12.2
261
121
42.7
0.81
23
3.17
11.6
248
115
63
47.7
0.88
21
3.28
12.1
259
120
46.3
0.84
22
3.25
12.0
256
118
45.4
0.79
24
3.30
12.1
265
127
49.2
0.82
23
3.38
12.5
273
130
50.7
0.86
22
3.41
12.6
276
132
45.6
0.66
20
3.27
12.0
262
125
67
50.9
0.72
19
3.38
12.5
273
130
49.5
0.68
19
3.36
12.4
270
129
* Entering Indoor Dry Bulb Temperature
1600
1800
59
46.7
0.94
22
3.21
11.8
240
112
45.3
0.90
23
3.18
11.7
238
111
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
48.5
0.64
20
3.41
12.6
276
135
52.5
0.66
20
3.50
13.0
285
139
54.1
0.70
19
3.53
13.1
288
140
48.8
0.49
16
3.38
12.5
274
133
71
54.4
0.54
15
3.50
13.0
285
139
52.9
0.51
16
3.47
12.9
282
138
41.5
0.94
26
3.38
12.4
262
115
45.0
0.97
25
3.46
12.8
270
119
46.4
1.00
24
3.49
12.9
272
120
40.8
0.90
24
3.35
12.3
259
114
59
45.6
1.00
23
3.46
12.8
270
119
44.2
0.93
24
3.43
12.7
267
118
44.4
0.82
24
3.56
13.2
297
134
48.1
0.85
23
3.65
13.5
306
138
49.5
0.89
22
3.69
13.7
309
139
44.6
0.68
20
3.53
13.0
294
132
67
49.7
0.74
19
3.65
13.5
306
138
48.3
0.71
20
3.62
13.4
303
136
47.3
0.66
21
3.68
13.7
310
142
51.3
0.69
20
3.78
14.1
320
147
52.8
0.72
19
3.81
14.2
323
148
47.7
0.51
16
3.65
13.5
307
141
71
53.2
0.56
15
3.78
14.1
320
147
51.6
0.53
16
3.75
13.9
316
145
40.6
0.96
26
3.59
13.5
297
120
43.9
1.00
25
3.69
13.9
307
123
45.3
1.00
23
3.72
14.0
310
125
39.9
0.92
24
3.56
13.4
295
118
59
44.5
1.00
23
3.69
13.9
307
123
43.2
0.95
24
3.66
13.8
304
122
41.3
0.93
25
3.67
13.9
320
127
44.8
0.96
25
3.77
14.3
330
131
46.1
1.00
24
3.80
14.4
333
133
40.7
0.86
23
3.64
13.7
317
126
43.3
0.84
24
3.79
14.3
338
139
46.9
0.87
23
3.89
14.8
349
143
48.3
0.91
22
3.93
14.9
352
145
43.5
0.70
20
3.76
14.2
335
138
46.2
0.68
21
3.92
14.9
353
148
50.1
0.71
20
4.03
15.3
363
153
51.6
0.74
19
4.06
15.5
367
154
46.5
0.52
16
3.89
14.7
349
147
39.6
0.99
26
3.78
14.5
339
126
42.9
1.00
25
3.88
14.9
349
130
44.2
1.00
23
3.92
15.0
353
131
38.9
0.95
24
3.75
14.3
335
124
40.3
0.96
25
3.87
14.8
365
134
43.7
0.99
25
3.97
15.3
376
138
45.0
1.00
23
4.01
15.4
380
139
39.7
0.89
23
3.84
14.7
361
132
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
45.5
48.6 51.9 43.4
44.3
0.94
0.76 0.57 1.00
0.97
22
19
15
22
22
3.77
3.89 4.03 3.88
3.97
14.3
14.8 15.3 14.9
15.3
330
349
363
349
376
131
143
153
130
138
44.1
47.2 50.4 42.1
43.1
0.89
0.73 0.54 0.98
0.92
23
20
16
24
23
3.74
3.86 3.99 3.85
3.94
14.1
14.6 15.2 14.8
15.1
327
345
360
346
372
130
142
151
128
136
NOTE: Shaded area is AHRI Rating Conditions
42.4
0.91
25
3.45
12.7
281
122
45.9
0.94
25
3.54
13.1
290
126
47.3
0.98
24
3.57
13.2
293
128
41.7
0.84
23
3.42
12.6
279
121
63
46.6
0.91
22
3.54
13.1
290
126
45.2
0.87
23
3.51
13.0
287
125
75
MODEL: GSX13048-1AA / CA*F4860*6** / ZP39K5E-PFV
42.2
0.86
24
4.00
15.3
385
146
45.8
0.90
24
4.10
15.8
397
150
47.1
0.94
23
4.14
15.9
401
152
46.0
0.75
20
4.07
15.7
393
149
42.5
0.72
20
3.97
15.2
381
145
67
47.4
0.79
19
4.10
15.8
397
150
45.1
0.70
21
4.14
15.9
402
155
48.8
0.73
20
4.25
16.4
414
160
50.3
0.76
20
4.28
16.6
418
162
45.4
0.54
16
4.10
15.8
398
154
71
50.6
0.59
15
4.25
16.4
414
160
49.2
0.56
16
4.21
16.3
410
159
EXPANDED PERFORMANCE DATA
37.6
1.00
25
3.95
15.4
381
132
40.7
1.00
23
4.05
15.9
393
136
42.0
1.00
21
4.09
16.0
397
137
36.9
0.98
24
3.91
15.3
377
130
59
41.2
1.00
21
4.05
15.9
393
136
40.0
1.00
23
4.02
15.7
389
134
38.3
0.99
25
4.04
15.8
410
140
41.5
1.00
24
4.14
16.3
423
144
42.8
1.00
22
4.18
16.4
427
146
37.8
0.92
23
4.00
15.7
406
139
63
42.1
1.00
22
4.14
16.3
423
144
40.9
0.96
22
4.11
16.1
419
143
40.1
0.90
24
4.17
16.4
433
153
43.5
0.93
23
4.28
16.8
447
158
44.8
0.98
22
4.32
17.0
451
159
40.3
0.75
20
4.14
16.2
429
151
67
45.0
0.82
19
4.28
16.8
447
158
43.7
0.78
20
4.25
16.7
442
156
105
42.8
0.73
20
4.32
17.0
452
163
46.4
0.76
20
4.43
17.5
466
168
47.8
0.79
19
4.47
17.7
470
170
43.1
0.56
16
4.28
16.8
447
161
71
48.1
0.61
15
4.43
17.5
466
168
46.7
0.58
16
4.39
17.3
461
166
34.8
1.00
23
4.09
16.4
421
136
37.7
1.00
22
4.20
16.9
434
140
38.9
1.00
20
4.23
17.0
439
142
34.2
0.99
22
4.05
16.2
417
135
59
38.2
1.00
20
4.20
16.9
434
140
37.1
1.00
21
4.16
16.7
430
139
35.5
1.00
23
4.18
16.8
453
145
38.5
1.00
22
4.29
17.3
467
149
39.6
1.00
20
4.33
17.4
472
151
35.0
0.93
21
4.15
16.6
449
144
63
39.0
1.00
20
4.29
17.3
467
149
37.9
0.96
21
4.26
17.1
463
148
37.2
0.91
22
4.32
17.4
479
158
40.3
0.94
22
4.44
17.9
493
163
41.5
0.98
21
4.48
18.0
498
165
37.4
0.76
19
4.29
17.2
474
157
67
41.7
0.82
18
4.44
17.9
493
163
40.5
0.78
18
4.40
17.7
488
162
115
39.7
0.73
19
4.47
18.0
499
169
43.0
0.76
19
4.59
18.6
515
174
44.3
0.80
18
4.63
18.8
520
175
39.9
0.57
15
4.43
17.9
494
167
71
44.6
0.62
14
4.59
18.6
515
174
43.3
0.59
15
4.55
18.4
510
172
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130481A*
23
24
75
70
IDB*
54.2
0.67
20
3.95
14.7
231
101
50.1
0.65
20
3.85
14.3
224
98
56.8
0.80
22
4.01
15.0
235
103
55.1
0.76
23
3.98
14.8
233
102
50.9
0.73
23
3.88
14.4
226
99
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1700
1488
1913
1700
1488
63
52.4
0.66
21
3.96
14.8
243
105
56.8
0.68
21
4.06
15.2
251
108
58.5
0.71
20
4.09
15.3
253
110
51.9
0.54
17
3.93
14.6
241
104
56.2
0.56
17
4.03
15.0
248
107
57.9
0.59
16
4.06
15.2
251
108
67
56.7
0.50
17
4.09
15.3
257
115
61.5
0.52
17
4.19
15.7
265
118
63.3
0.54
16
4.22
15.9
268
120
56.8
0.37
13
4.05
15.1
254
114
61.6
0.39
13
4.15
15.6
262
117
63.4
0.41
12
4.19
15.7
265
118
* Entering Indoor Dry Bulb Temperature
1913
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
59
55.9
0.70
19
3.98
14.8
233
102
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
60.9
0.32
12
4.22
15.9
268
122
66.0
0.33
12
4.32
16.3
276
126
67.9
0.35
11
4.36
16.5
279
127
-
-
-
71
59
49.7
0.76
23
4.18
15.6
254
105
53.9
0.79
23
4.28
16.1
262
108
55.5
0.83
22
4.31
16.2
264
109
48.9
0.67
20
4.14
15.5
251
103
53.0
0.69
20
4.25
15.9
259
107
54.6
0.73
19
4.28
16.1
262
108
63
67
55.4
0.52
18
4.40
16.6
288
121
60.0
0.53
17
4.51
17.0
297
125
61.8
0.56
17
4.55
17.2
300
126
55.5
0.39
13
4.36
16.4
285
120
60.1
0.40
13
4.47
16.9
294
124
62.0
0.42
13
4.51
17.0
297
125
59.5
0.33
12
4.54
17.2
301
129
64.4
0.34
12
4.66
17.7
310
133
66.4
0.36
12
4.69
17.9
313
135
-
-
-
71
59
48.5
0.78
23
4.44
17.0
289
109
52.6
0.81
23
4.55
17.5
298
112
54.2
0.85
22
4.58
17.7
301
113
47.7
0.69
20
4.40
16.9
286
108
51.7
0.71
20
4.51
17.3
295
111
53.3
0.75
19
4.55
17.5
297
112
50.0
0.70
22
4.53
17.4
311
116
54.1
0.72
21
4.65
18.0
320
119
55.8
0.76
20
4.68
18.1
323
120
49.5
0.57
18
4.49
17.3
307
114
53.6
0.60
17
4.61
17.8
317
118
55.2
0.62
17
4.65
18.0
320
119
54.1
0.53
18
4.68
18.0
328
126
58.6
0.55
17
4.80
18.6
338
130
60.4
0.57
17
4.84
18.8
342
131
54.2
0.40
13
4.64
17.9
325
125
58.7
0.41
13
4.76
18.4
335
129
60.5
0.43
13
4.79
18.6
338
130
58.1
0.34
12
4.83
18.8
342
134
62.9
0.35
12
4.95
19.3
353
139
64.8
0.37
12
4.99
19.5
356
140
-
-
-
47.3
0.81
24
4.67
18.2
329
114
51.3
0.84
23
4.78
18.8
339
118
52.8
0.88
22
4.82
18.9
342
119
46.6
0.71
20
4.63
18.1
325
113
50.4
0.74
20
4.74
18.6
335
116
52.0
0.77
19
4.78
18.8
339
118
48.8
0.72
22
4.77
18.7
354
121
52.8
0.75
21
4.89
19.2
365
125
54.4
0.78
21
4.93
19.4
368
126
48.3
0.59
18
4.73
18.5
350
120
52.3
0.61
17
4.85
19.1
361
124
53.9
0.64
17
4.89
19.2
365
125
52.8
0.55
18
4.92
19.3
374
133
57.2
0.57
17
5.05
19.9
385
137
58.9
0.59
17
5.09
20.1
389
138
52.9
0.41
13
4.88
19.2
370
131
57.3
0.43
13
5.01
19.7
381
135
59.0
0.45
13
5.05
19.9
385
137
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
NOTE: Shaded area is ACCA (TVA) conditions
51.2
0.68
22
4.27
16.0
273
111
55.5
0.71
21
4.37
16.5
282
115
57.1
0.74
20
4.41
16.6
284
116
50.7
0.56
18
4.23
15.9
270
110
54.9
0.58
17
4.34
16.3
279
113
56.5
0.61
17
4.37
16.5
281
115
75
MODEL: GSX130601A* / CA*F4860*6**/ ZP51K5E-PFV
56.6
0.35
12
5.08
20.1
390
141
61.4
0.36
12
5.22
20.7
402
146
63.2
0.38
12
5.26
20.9
406
147
-
-
-
71
EXPANDED PERFORMANCE DATA
59
45.0
0.84
23
4.86
19.4
370
120
48.7
0.87
23
4.98
20.0
381
123
50.2
0.91
22
5.03
20.2
385
125
44.2
0.74
20
4.82
19.3
366
118
47.9
0.76
20
4.94
19.8
377
122
49.4
0.80
19
4.98
20.0
381
123
63
46.3
0.75
21
4.97
19.9
398
127
50.2
0.78
21
5.09
20.5
410
131
51.7
0.81
20
5.14
20.7
414
132
45.8
0.61
17
4.93
19.7
394
126
49.7
0.64
17
5.05
20.3
406
130
51.2
0.67
16
5.09
20.5
410
131
67
50.1
0.57
18
5.13
20.6
420
139
54.3
0.59
17
5.26
21.2
433
143
55.9
0.62
17
5.31
21.4
438
145
50.2
0.43
13
5.09
20.4
416
137
54.4
0.44
13
5.22
21.0
429
142
56.1
0.46
12
5.26
21.2
433
143
105
53.8
0.36
12
5.30
21.4
438
148
58.3
0.38
12
5.44
22.1
452
152
60.0
0.40
11
5.48
22.3
456
154
-
-
-
71
59
41.7
0.84
22
5.03
20.6
409
124
45.1
0.88
21
5.16
21.3
421
128
46.5
0.92
21
5.20
21.5
425
129
41.0
0.74
19
4.99
20.4
404
122
44.4
0.77
18
5.11
21.0
417
126
45.7
0.81
18
5.16
21.2
421
127
63
42.9
0.75
20
5.14
21.2
440
132
46.5
0.78
20
5.27
21.8
453
136
47.9
0.82
19
5.32
22.0
458
137
42.5
0.62
16
5.10
21.0
435
130
46.0
0.64
16
5.23
21.6
449
134
47.4
0.67
15
5.27
21.8
453
136
67
46.4
0.57
16
5.31
21.9
464
144
50.3
0.59
16
5.45
22.6
479
148
51.8
0.62
15
5.49
22.8
483
150
46.5
0.43
12
5.26
21.7
460
142
50.4
0.45
12
5.40
22.3
474
147
51.9
0.47
12
5.45
22.5
479
148
115
49.8
0.37
11
5.49
22.8
484
153
54.0
0.38
11
5.63
23.4
499
158
55.6
0.40
11
5.68
23.7
504
159
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130601A*
85
80
IDB*
56.1
0.84
25
4.01
15.0
236
103
51.8
0.81
26
3.91
14.5
228
100
58.8
0.92
26
4.07
15.2
240
105
57.1
0.88
27
4.04
15.1
238
104
52.7
0.85
28
3.94
14.7
231
101
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1700
1488
53.7
0.82
27
4.03
15.0
248
107
58.2
0.85
27
4.13
15.5
256
111
60.0
0.89
26
4.16
15.6
259
112
57.4
0.78
24
4.09
15.3
253
110
52.9
0.76
25
4.00
14.9
246
106
63
59.1
0.82
23
4.13
15.5
256
111
56.3
0.74
26
4.15
15.6
262
117
61.0
0.76
25
4.25
16.0
270
121
62.8
0.80
24
4.29
16.2
273
122
61.3
0.64
21
4.22
15.9
268
120
56.6
0.62
22
4.12
15.4
260
116
67
63.1
0.67
20
4.25
16.0
270
121
* Entering Indoor Dry Bulb Temperature
1913
1488
1700
1913
59
57.8
0.88
24
4.04
15.1
238
104
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
60.0
0.60
22
4.28
16.2
273
125
65.0
0.62
22
4.39
16.6
282
129
67.0
0.65
21
4.43
16.8
285
130
65.5
0.48
17
4.36
16.5
279
127
60.5
0.46
17
4.25
16.0
271
124
71
67.5
0.50
16
4.39
16.6
282
129
51.5
0.88
28
4.24
15.9
259
107
55.8
0.91
27
4.35
16.4
267
110
57.5
0.95
26
4.38
16.5
270
111
54.8
0.87
26
4.31
16.2
264
109
50.6
0.84
26
4.21
15.8
256
106
59
56.5
0.91
25
4.35
16.4
267
110
55.0
0.76
26
4.47
16.9
294
124
59.6
0.79
25
4.58
17.4
303
128
61.3
0.83
24
4.62
17.5
306
129
59.9
0.66
21
4.55
17.2
300
126
55.2
0.64
22
4.44
16.7
291
123
67
61.6
0.69
21
4.58
17.4
303
128
58.6
0.62
22
4.62
17.5
307
132
63.5
0.64
22
4.73
18.0
316
136
65.4
0.67
21
4.77
18.2
320
137
64.0
0.49
17
4.70
17.9
313
135
59.1
0.48
17
4.58
17.4
304
131
71
65.9
0.52
16
4.73
18.0
316
136
50.3
0.90
28
4.51
17.3
294
111
54.5
0.93
27
4.62
17.9
304
114
56.1
0.98
26
4.66
18.0
307
115
53.5
0.89
26
4.58
17.7
301
113
49.4
0.86
26
4.47
17.2
292
110
59
55.1
0.93
25
4.62
17.9
304
114
51.2
0.87
27
4.61
17.8
317
118
55.5
0.90
27
4.72
18.3
327
122
57.2
0.94
26
4.76
18.5
330
123
54.7
0.83
25
4.68
18.1
323
120
50.5
0.80
25
4.57
17.6
314
117
53.7
0.78
26
4.75
18.4
335
129
58.1
0.81
25
4.88
18.9
345
133
59.9
0.85
24
4.92
19.1
348
134
58.4
0.68
21
4.84
18.8
342
131
53.9
0.65
22
4.72
18.2
331
127
57.2
0.63
22
4.91
19.1
349
137
62.0
0.66
22
5.04
19.7
360
141
63.9
0.69
21
5.08
19.9
363
143
62.5
0.51
17
5.00
19.5
356
140
57.6
0.49
17
4.87
18.9
346
136
NOTE: Shaded area is AHRI Rating Conditions
52.5
0.85
27
4.33
16.3
279
113
56.9
0.88
27
4.44
16.8
287
117
58.6
0.92
26
4.48
16.9
290
118
56.0
0.81
25
4.41
16.6
284
116
51.7
0.78
25
4.30
16.2
276
112
63
57.7
0.85
24
4.44
16.8
287
117
75
49.0
0.93
28
4.74
18.6
335
116
53.1
0.96
28
4.86
19.1
346
120
54.7
1.00
26
4.90
19.3
349
121
52.2
0.92
26
4.82
18.9
342
119
48.2
0.88
26
4.70
18.4
332
115
50.0
0.89
28
4.85
19.1
361
124
54.2
0.93
27
4.97
19.6
372
128
55.8
0.97
26
5.01
19.8
376
129
53.4
0.86
25
4.93
19.4
368
126
49.2
0.83
25
4.81
18.9
357
123
52.3
0.81
26
5.00
19.7
381
135
56.7
0.84
26
5.13
20.3
393
139
58.4
0.88
25
5.18
20.5
397
141
57.0
0.70
22
5.09
20.1
389
138
52.6
0.67
22
4.96
19.5
377
134
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
56.3 60.2 64.3 53.8
55.0
58.7
0.87 0.71 0.53 0.96
0.90
0.73
24
21
16
25
24
21
4.72 4.88 5.04 4.86
4.97
5.13
18.3 18.9 19.7 19.1
19.6
20.3
327
345
360
346
372
393
122
133
141
120
128
139
55.8
0.65
23
5.17
20.5
397
144
60.5
0.68
22
5.30
21.1
410
148
62.3
0.71
21
5.35
21.3
414
150
60.9
0.52
17
5.26
20.9
406
147
56.2
0.50
18
5.13
20.3
394
143
71
62.8
0.55
17
5.30
21.1
410
148
EXPANDED PERFORMANCE DATA
MODEL: GSX130601AA / CA*F4860*6**/ ZP51K5E-PFV
46.6
0.96
28
4.94
19.8
377
122
50.5
1.00
27
5.07
20.4
389
126
52.0
1.00
25
5.11
20.6
393
127
49.6
0.95
26
5.03
20.2
385
125
45.8
0.92
26
4.90
19.6
374
121
59
51.1
1.00
25
5.07
20.4
389
126
47.5
0.93
27
5.05
20.3
406
130
51.4
0.96
27
5.18
20.9
419
134
53.0
1.00
25
5.22
21.1
423
135
50.7
0.89
24
5.14
20.7
414
132
46.8
0.86
25
5.01
20.1
402
129
63
52.2
0.94
23
5.18
20.9
419
134
49.7
0.84
26
5.22
21.0
429
142
53.9
0.87
25
5.35
21.6
442
146
55.5
0.91
24
5.40
21.9
446
148
54.2
0.73
21
5.31
21.4
438
145
50.0
0.70
22
5.17
20.8
424
140
67
55.8
0.76
20
5.35
21.6
442
146
105
53.1
0.68
22
5.39
21.9
447
151
57.5
0.70
22
5.53
22.5
461
156
59.2
0.74
21
5.58
22.7
466
157
57.9
0.54
17
5.48
22.3
456
154
53.4
0.52
17
5.35
21.6
443
149
71
59.6
0.57
16
5.53
22.5
461
156
43.1
0.97
26
5.11
21.0
417
126
46.7
1.00
25
5.24
21.7
430
130
48.2
1.00
23
5.29
21.9
434
131
45.9
0.96
24
5.20
21.5
426
129
42.4
0.93
24
5.07
20.8
413
125
59
47.3
1.00
23
5.24
21.7
430
130
44.0
0.94
25
5.23
21.6
449
134
47.7
0.97
25
5.36
22.2
462
138
49.1
1.00
24
5.41
22.4
467
140
46.9
0.90
23
5.32
22.0
458
137
43.3
0.87
23
5.18
21.4
444
133
63
48.4
0.94
22
5.36
22.2
462
138
46.1
0.84
24
5.40
22.3
474
147
49.9
0.88
24
5.54
23.0
488
151
51.4
0.92
23
5.59
23.2
493
153
50.2
0.73
20
5.49
22.8
484
150
46.3
0.71
20
5.35
22.1
469
145
67
51.7
0.77
19
5.54
23.0
488
151
115
49.1
0.69
21
5.58
23.2
494
156
53.2
0.71
20
5.73
23.9
509
161
54.8
0.75
20
5.78
24.1
514
163
53.6
0.55
16
5.68
23.7
504
159
49.5
0.53
16
5.53
23.0
489
155
71
55.2
0.57
15
5.73
23.9
509
161
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130601A*
25
26
75
70
IDB*
63
16.4
0.56
16
1.30
4.7
218
109
17.7
0.58
16
1.33
4.8
225
113
18.3
0.61
15
1.34
4.8
227
114
16.5
0.68
20
1.31
4.7
220
111
17.9
0.70
19
1.34
4.8
227
114
59
15.8
0.67
18
1.27
4.6
203
103
17.1
0.69
18
1.30
4.7
209
106
17.6
0.73
17
1.31
4.7
211
107
MBh
16.1
S/T
0.76
Delta T 21
KW
1.28
AMPS 4.6
HI PR 205
LO PR 104
MBh
17.4
S/T
0.79
Delta T 21
KW
1.31
AMPS 4.7
HI PR 211
LO PR 107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
19.4
0.53
16
1.38
5.0
240
124
17.9
0.51
16
1.35
4.9
233
121
67
17.9
0.39
12
1.34
4.8
230
119
19.4
0.40
12
1.37
5.0
238
123
20.0
0.42
11
1.38
5.0
240
124
20.8
0.34
11
1.42
5.2
250
132
19.2
0.33
11
1.39
5.0
243
128
71
-
17.0
0.81
21
1.40
5.1
237
113
15.7
0.79
22
1.37
5.0
230
110
59
15.4
0.69
19
1.36
4.9
228
109
16.7
0.72
18
1.39
5.1
235
112
17.2
0.75
18
1.40
5.1
237
113
17.5
0.73
20
1.43
5.2
255
120
16.2
0.70
20
1.40
5.1
247
117
63
16.0
0.58
16
1.39
5.0
245
116
17.3
0.60
16
1.42
5.2
252
119
17.9
0.63
15
1.43
5.2
255
120
75
19.0
0.55
16
1.48
5.4
269
131
17.5
0.53
16
1.44
5.2
261
127
67
17.5
0.40
12
1.43
5.2
259
126
19.0
0.41
12
1.46
5.3
267
130
19.6
0.43
12
1.48
5.4
269
131
20.3
0.35
11
1.52
5.6
281
140
18.8
0.34
11
1.49
5.4
272
136
71
-
16.6
0.84
21
1.49
5.5
270
118
15.3
0.81
22
1.45
5.4
261
114
59
15.1
0.71
19
1.44
5.3
259
113
16.3
0.74
18
1.48
5.5
267
116
16.8
0.77
18
1.49
5.5
270
118
18.5
0.57
16
1.56
5.8
306
137
17.1
0.55
16
1.53
5.7
297
132
19.9
0.36
11
1.61
6.1
319
145
18.3
0.35
11
1.57
5.9
310
141
17.6 19.1 20.5
0.78 0.59 0.38
19
15
11
1.53 1.57 1.62
5.7
5.9
6.1
293
309
323
126
138
147
(TVA) conditions
17.1
0.75
20
1.52
5.7
290
125
15.8
0.72
20
1.48
5.5
281
121
16.7
0.90
21
1.57
6.0
310
125
16.2
0.86
21
1.56
5.9
307
124
15.0
0.83
22
1.52
5.7
298
120
18.1
0.58
16
1.64
6.2
349
143
16.7
0.77
20
1.59
6.0
330
131
17.2
0.81
19
1.60
6.1
334
133
18.6
0.61
16
1.65
6.3
352
145
16.7
0.56
16
1.60
6.1
338
139
15.4
0.74
20
1.55
5.9
320
127
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
15.6 17.1
14.7
15.2
16.7
0.59 0.41
0.73
0.61
0.42
16
12
19
16
12
1.47 1.51
1.51
1.54
1.59
5.5
5.6
5.7
5.8
6.0
279
294
295
317
335
120
131
119
126
138
16.9 18.5
15.9
16.5
18.1
0.61 0.43
0.76
0.63
0.44
16
12
19
16
12
1.51 1.55
1.55
1.58
1.63
5.6
5.8
5.9
6.0
6.2
287
303
304
327
345
124
135
122
130
142
17.4 19.1
16.4
17.0
18.6
0.64 0.45
0.80
0.66
0.46
15
12
18
15
12
1.52 1.56
1.56
1.59
1.64
5.7
5.8
5.9
6.0
6.2
290
306
307
330
349
125
137
123
131
143
20.0
0.39
11
1.70
6.5
368
154
19.4
0.38
11
1.69
6.5
364
153
17.9
0.36
11
1.65
6.3
353
148
71
-
EXPANDED PERFORMANCE DATA
MBh
17.9 18.5 20.0 21.5 17.5 18.0 19.5 21.0 17.1
S/T
0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88
Delta T 20
19
15
10
20
19
15
11
20
675
KW
1.32 1.35 1.39 1.43 1.42 1.44 1.49 1.53 1.50
AMPS 4.8
4.9
5.0
5.2
5.1
5.3
5.4
5.6
5.6
HI PR 213
230
242
253
239
258
272
284
272
LO PR 108
115
126
134
114
122
133
141
119
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction service valves.
600
525
675
600
525
Airflow
65
MODEL: GSX130181B* / CA*F1824*6B*
15.8
0.80
19
1.65
6.4
372
138
14.6
0.77
20
1.62
6.3
361
134
63
14.5
0.63
16
1.60
6.2
357
132
15.7
0.66
16
1.64
6.4
368
136
16.2
0.69
15
1.65
6.4
372
138
17.2
0.61
16
1.71
6.6
392
150
15.8
0.58
16
1.67
6.5
381
146
67
15.9
0.44
12
1.65
6.4
377
144
17.2
0.46
12
1.69
6.6
389
149
17.7
0.48
12
1.71
6.6
392
150
18.4
0.39
11
1.76
6.9
409
160
17.0
0.38
11
1.72
6.7
397
155
71
-
14.3
0.90
20
1.67
6.6
382
134
13.2
0.87
20
1.63
6.5
370
130
59
12.9
0.77
17
1.62
6.4
366
129
14.0
0.79
17
1.66
6.6
378
133
14.4
0.83
16
1.67
6.6
382
134
14.7
0.81
18
1.71
6.8
411
142
13.5
0.78
18
1.67
6.6
398
138
63
13.4
0.64
15
1.65
6.6
394
137
14.5
0.66
15
1.70
6.7
407
141
15.0
0.70
14
1.71
6.8
411
142
16.4
0.64
14
1.78
7.1
438
157
15.9
0.61
15
1.76
7.0
434
156
14.7
0.59
15
1.72
6.8
421
151
67
14.7
0.44
11
1.71
6.8
416
149
15.9
0.46
11
1.75
7.0
429
154
16.4
0.48
11
1.76
7.0
434
155
115
15.9 16.3 17.7 19.0 14.7 15.1
0.94 0.84 0.64 0.41 0.95 0.85
20
19
15
11
19
17
1.63 1.67 1.72 1.77 1.69 1.72
6.3
6.5
6.7
6.9
6.7
6.9
349
375
396
413
385
415
131
139
152
162
135
144
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
15.4
0.90
21
1.62
6.3
345
129
14.2
0.86
21
1.58
6.1
335
126
59
14.0
0.76
19
1.57
6.0
332
124
15.1
0.79
18
1.61
6.2
342
128
15.6
0.83
18
1.62
6.3
345
129
105
17.6
0.41
10
1.83
7.4
457
167
17.1
0.39
10
1.82
7.3
452
166
15.7
0.38
10
1.77
7.1
439
161
71
-
COOLING OPERATION
COOLING PERFORMANCE DATA GSX130181B*/VSX130181A*
85
80
IDB*
18.1
0.81
22
1.35
4.9
230
115
18.7
0.85
22
1.36
4.9
232
116
17.0
0.84
25
1.33
4.8
225
113
18.4
0.87
25
1.36
4.9
232
116
MBh
17.7
S/T
0.86
Delta T 23
KW
1.32
AMPS 4.8
HI PR 213
LO PR 108
MBh
18.3
S/T
0.90
Delta T 22
KW
1.33
AMPS 4.8
HI PR 215
LO PR 109
MBh
16.6
S/T
0.87
Delta T 25
KW
1.30
AMPS 4.7
HI PR 209
LO PR 106
MBh
18.0
S/T
0.90
Delta T 25
KW
1.33
AMPS 4.8
HI PR 215
LO PR 109
600
675
525
19.3
0.79
23
1.40
5.1
245
127
17.8
0.76
24
1.37
5.0
238
123
19.9
0.69
19
1.40
5.1
245
127
19.4
0.66
20
1.39
5.0
242
126
67
17.9
0.63
20
1.36
4.9
235
122
20.5
0.64
20
1.44
5.3
255
135
19.0
0.62
20
1.41
5.1
248
131
21.3
0.52
15
1.44
5.3
255
135
20.7
0.49
16
1.43
5.2
253
134
71
19.1
0.47
16
1.40
5.1
245
130
17.6
0.94
25
1.43
5.2
242
115
16.3
0.90
26
1.39
5.1
235
112
17.8
0.94
23
1.43
5.2
242
115
17.3
0.89
24
1.42
5.1
239
114
59
16.0
0.86
24
1.38
5.0
232
111
18.0
0.90
25
1.45
5.3
260
123
16.6
0.87
25
1.42
5.2
252
119
18.2
0.88
22
1.45
5.3
260
123
17.7
0.84
23
1.44
5.3
258
122
63
16.3
0.81
23
1.41
5.1
250
118
75
18.8
0.82
24
1.50
5.5
275
134
17.4
0.79
24
1.46
5.3
267
130
19.5
0.72
19
1.50
5.5
275
134
18.9
0.68
20
1.49
5.4
272
133
67
17.4
0.66
20
1.45
5.3
264
129
20.1
0.66
20
1.54
5.7
287
143
18.5
0.64
21
1.51
5.5
278
138
20.8
0.53
15
1.54
5.7
287
143
20.2
0.51
16
1.53
5.6
284
141
71
18.6
0.49
16
1.50
5.5
275
137
17.2
0.96
25
1.51
5.6
275
120
15.9
0.93
26
1.47
5.5
267
116
17.4
0.96
23
1.51
5.6
275
120
16.9
0.92
24
1.50
5.6
272
119
59
15.6
0.88
24
1.46
5.4
264
115
18.4
0.84
24
1.59
6.0
313
139
16.9
0.81
24
1.55
5.8
303
135
19.0
0.73
19
1.59
6.0
313
139
18.5
0.70
20
1.58
5.9
309
138
19.6
0.68
20
1.64
6.2
326
148
18.1
0.65
21
1.60
6.0
316
144
20.3
0.55
15
1.64
6.2
326
148
19.7
0.52
16
1.62
6.1
323
147
18.1 18.9 20.2
0.97 0.88 0.71
24
23
20
1.55 1.60 1.65
5.8
6.0
6.2
299
316
329
129
141
150
Rating Conditions
17.5
0.93
25
1.54
5.8
296
128
16.2
0.89
25
1.50
5.6
287
124
17.8
0.90
22
1.54
5.8
296
128
17.3
0.86
23
1.53
5.7
293
126
17.3
1.00
24
1.60
6.1
316
127
16.8
0.99
25
1.58
6.0
313
126
15.5
0.96
26
1.55
5.8
304
122
17.0
1.00
23
1.58
6.0
313
126
16.5
0.95
24
1.57
6.0
310
125
17.6
1.00
24
1.63
6.2
340
135
17.1
0.96
25
1.62
6.2
337
134
15.8
0.92
26
1.58
6.0
327
130
17.4
0.93
22
1.62
6.2
337
134
16.8
0.89
23
1.60
6.1
334
133
18.4
0.91
23
1.68
6.4
359
148
17.9
0.86
24
1.67
6.4
356
146
16.5
0.83
24
1.63
6.2
345
142
18.0
0.72
20
1.65
6.3
352
145
18.5
0.76
19
1.67
6.4
356
146
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
15.9 17.0 18.2 15.2
15.6
16.6
0.83 0.67 0.50 0.91
0.86
0.70
23
20
16
24
23
20
1.49 1.54 1.59 1.53
1.57
1.61
5.6
5.7
6.0
5.8
5.9
6.1
284
300
313
301
324
342
123
134
143
121
129
141
19.7
0.73
20
1.73
6.7
375
157
19.1
0.70
21
1.72
6.6
371
156
17.6
0.68
21
1.68
6.4
360
151
19.8
0.57
15
1.72
6.6
371
156
19.2
0.54
16
1.71
6.5
368
154
71
17.8
0.52
16
1.66
6.4
357
150
EXPANDED PERFORMANCE DATA
MBh
18.6 18.9 19.8 21.2 18.1 18.5 19.4 20.7 17.7
S/T
0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00
Delta T 24
24
22
19
24
24
23
20
24
675
KW
1.34 1.37 1.41 1.45 1.44 1.47 1.51 1.56 1.52
AMPS 4.9
5.0
5.1
5.3
5.2
5.4
5.5
5.7
5.7
HI PR 218
234
247
258
244
263
278
289
278
LO PR 110
117
128
136
117
124
135
144
121
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction service valves.
600
525
63
16.7
0.78
23
1.32
4.8
223
112
59
MBh
16.4
S/T
0.83
Delta T 24
KW
1.29
AMPS 4.6
HI PR 207
LO PR 105
Airflow
65
MODEL: GSX130181B* / CA*F1824*6B*
16.2
0.99
25
1.68
6.5
379
140
15.0
0.96
25
1.64
6.4
368
136
16.5
0.97
22
1.68
6.5
379
140
16.0
0.92
23
1.67
6.5
375
139
63
14.8
0.89
23
1.63
6.3
364
135
17.0
0.90
23
1.73
6.8
400
153
15.7
0.86
24
1.69
6.6
388
149
17.6
0.79
19
1.73
6.8
400
153
17.1
0.75
20
1.72
6.7
396
152
67
15.8
0.72
20
1.68
6.5
385
147
18.2
0.73
20
1.79
7.0
418
163
16.8
0.70
21
1.75
6.8
405
158
18.8
0.59
15
1.79
7.0
418
163
18.3
0.56
16
1.77
6.9
413
162
71
16.9
0.54
16
1.73
6.8
401
157
14.8
1.00
23
1.70
6.8
389
137
13.6
1.00
24
1.66
6.6
378
132
14.9
1.00
20
1.70
6.8
389
137
14.5
0.99
22
1.69
6.7
385
135
59
13.4
0.95
22
1.65
6.5
374
131
15.0
1.00
23
1.74
6.9
419
145
13.9
0.97
23
1.69
6.7
406
141
15.3
1.00
21
1.74
6.9
419
145
14.8
0.93
21
1.72
6.9
415
144
63
13.7
0.90
21
1.68
6.7
402
140
16.2
0.95
21
1.81
7.2
447
160
15.8
0.90
22
1.79
7.2
442
159
14.5
0.87
22
1.75
7.0
429
154
16.3
0.79
18
1.79
7.2
442
159
15.8
0.76
18
1.78
7.1
438
157
67
14.6
0.73
19
1.73
6.9
425
152
115
16.4 16.7 17.5 18.7 15.2 15.5
1.00 1.00 0.94 0.76 1.00 1.00
22
23
22
19
21
21
1.66 1.69 1.75 1.80 1.71 1.75
6.4
6.6
6.8
7.1
6.8
7.0
356
383
404
422
393
423
133
142
155
165
138
147
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
15.9
1.00
24
1.65
6.4
352
132
14.7
0.99
26
1.61
6.2
342
128
16.1
1.00
22
1.65
6.4
352
132
15.7
0.98
24
1.63
6.3
349
131
59
14.5
0.95
24
1.59
6.2
338
127
105
17.3
0.77
18
1.86
7.5
466
171
16.8
0.73
19
1.85
7.4
461
169
15.5
0.71
19
1.80
7.2
448
164
17.4
0.59
14
1.85
7.4
461
169
16.9
0.56
15
1.83
7.4
457
167
71
15.6
0.54
15
1.79
7.2
443
162
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130181B*/VSX130181A*
27
28
75
70
IDB*
59
17.8
0.75
18
1.26
10.8
209
106
17.3
0.71
19
1.25
10.8
207
105
16.0
0.69
19
1.22
10.7
201
102
18.1
0.85
21
1.26
10.8
211
108
17.6
0.81
22
1.26
10.8
209
106
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
18.1
0.72
20
1.28
10.9
225
113
18.7
0.76
19
1.29
10.9
227
114
63
18.5
0.62
16
1.28
10.9
225
113
17.9
0.59
16
1.27
10.9
223
112
16.6
0.57
17
1.24
10.7
216
109
19.6
0.55
16
1.32
11.0
238
124
20.2
0.57
16
1.33
11.1
240
125
67
20.3
0.43
12
1.32
11.0
238
124
19.7
0.41
12
1.31
11.0
235
122
18.1
0.40
13
1.28
10.9
228
119
21.1
0.35
11
1.35
11.2
248
132
21.7
0.37
11
1.36
11.2
250
133
71
-
17.2
0.84
22
1.34
11.1
235
112
17.7
0.88
21
1.35
11.2
237
114
59
17.4
0.77
18
1.34
11.1
235
112
16.9
0.74
19
1.33
11.1
232
111
15.6
0.71
19
1.30
11.0
225
108
17.7
0.75
20
1.37
11.2
253
120
18.2
0.79
20
1.38
11.3
255
121
63
18.1
0.65
16
1.37
11.2
253
120
17.5
0.62
17
1.36
11.2
250
118
16.2
0.59
17
1.33
11.1
243
115
75
19.2
0.57
17
1.41
11.4
267
131
19.7
0.60
16
1.42
11.4
269
132
67
19.8
0.45
12
1.41
11.4
267
131
19.2
0.43
13
1.40
11.3
264
129
17.7
0.41
13
1.37
11.2
256
125
20.6
0.37
12
1.45
11.6
278
139
21.2
0.38
11
1.46
11.6
281
141
71
-
16.8
0.86
22
1.42
11.5
267
117
17.3
0.90
21
1.43
11.6
270
118
59
17.0
0.79
18
1.42
11.5
267
117
16.5
0.76
19
1.41
11.5
264
116
15.2
0.73
19
1.38
11.3
256
112
18.7
0.58
17
1.49
11.8
303
136
19.3
0.61
16
1.50
11.8
306
137
20.1
0.37
12
1.54
12.0
316
145
20.7
0.39
11
1.55
12.0
320
146
16.0 17.3 18.5
0.74 0.56 0.36
21
17
12
1.42 1.46 1.50
11.5 11.7 11.8
279
294
307
121
132
140
(TVA) conditions
17.3
0.77
20
1.45
11.6
287
124
17.8
0.81
20
1.46
11.7
290
126
15.1
0.86
23
1.45
11.7
295
119
16.4
0.89
22
1.49
11.8
304
123
16.9
0.93
21
1.50
11.9
307
124
18.3
0.60
17
1.57
12.1
346
143
16.8
0.58
17
1.53
12.0
335
138
17.4
0.83
20
1.53
12.0
331
132
16.9
0.79
21
1.52
12.0
327
131
15.6
0.77
21
1.48
11.8
317
127
18.8
0.63
16
1.58
12.2
349
144
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
17.6 19.3
16.6
17.2
18.8
0.66 0.46
0.82
0.68
0.47
16
12
19
16
12
1.45 1.49
1.49
1.52
1.56
11.6 11.8
11.8
12.0
12.1
287
303
304
327
346
124
136
123
131
143
17.1 18.7
16.1
16.7
18.3
0.63 0.44
0.78
0.65
0.45
17
13
19
17
13
1.44 1.48
1.48
1.51
1.55
11.6 11.7
11.8
11.9
12.1
284
300
301
324
342
123
134
122
129
141
15.8 17.3
14.9
15.4
16.9
0.61 0.42
0.75
0.63
0.44
17
13
20
17
13
1.41 1.45
1.44
1.47
1.52
11.5 11.6
11.7
11.8
11.9
276
291
292
314
332
119
130
118
125
137
18.1
0.37
12
1.58
12.2
350
147
19.6
0.39
12
1.61
12.4
360
152
20.2
0.41
11
1.63
12.4
364
153
71
-
EXPANDED PERFORMANCE DATA
MBh
16.3 16.7 18.1 19.4 15.9 16.3 17.7 19.0 15.5
S/T
0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83
DT
22
20
17
12
22
21
17
12
23
525
KW
1.23 1.25 1.29 1.32 1.31 1.34 1.38 1.42 1.39
AMPS 10.7 10.8 10.9 11.1 11.0 11.1 11.3 11.4 11.4
HI PR 203
218
231
241
228
245
259
270
259
LO PR 103
110
120
128
109
116
127
135
113
* Entering Indoor Dry Bulb Tem perature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction service valves.
600
675
525
600
675
Airflow
65
MODEL: VSX130181B* / CA*F1824*6
16.0
0.82
20
1.58
12.3
368
137
16.5
0.86
19
1.59
12.4
372
138
63
16.3
0.71
16
1.58
12.3
368
137
15.9
0.68
16
1.57
12.3
364
136
14.6
0.65
17
1.53
12.1
354
131
17.3
0.62
17
1.63
12.5
389
149
17.9
0.65
16
1.64
12.6
393
151
67
17.9
0.49
12
1.63
12.5
389
149
17.4
0.47
12
1.61
12.4
385
148
16.0
0.45
13
1.58
12.3
373
144
18.6
0.40
11
1.68
12.7
406
159
19.2
0.42
11
1.69
12.8
410
161
71
-
14.4
0.93
21
1.60
12.5
378
133
14.8
0.97
20
1.61
12.6
382
134
59
14.6
0.86
17
1.60
12.5
378
133
14.2
0.82
18
1.58
12.5
374
132
13.1
0.79
18
1.55
12.3
363
128
14.8
0.83
19
1.63
12.6
407
142
15.3
0.87
18
1.64
12.7
411
143
63
15.1
0.72
15
1.63
12.6
407
142
14.7
0.68
15
1.62
12.6
403
140
13.6
0.66
16
1.58
12.4
391
136
14.8
0.61
16
1.64
12.7
417
150
16.1
0.63
15
1.68
12.9
430
155
16.5
0.66
15
1.69
12.9
434
156
67
16.6
0.50
11
1.68
12.8
430
155
16.1
0.47
12
1.67
12.8
425
153
14.9
0.46
12
1.63
12.6
412
148
115
14.4 14.8 16.0 17.2 13.3 13.7
0.89 0.79 0.60 0.39 0.90 0.80
22
21
17
12
21
19
1.51 1.54 1.59 1.64 1.56 1.59
12.0 12.2 12.3 12.6 12.3 12.5
332
357
377
393
367
395
125
133
145
154
129
137
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
15.6
0.92
22
1.55
12.2
342
129
16.0
0.97
21
1.56
12.2
346
130
59
15.8
0.85
18
1.55
12.2
342
129
15.3
0.81
19
1.53
12.1
339
127
14.1
0.78
19
1.50
12.0
329
124
105
15.9
0.39
11
1.69
12.9
435
160
17.2
0.40
11
1.73
13.1
448
165
17.8
0.42
10
1.75
13.1
453
166
71
-
COOLING O PERATION
COOLING PERFORMANCE DATA
GSX130181C*/VSX130181B*
85
80
IDB*
18.8
0.98
25
1.28
10.9
216
110
18.2
0.93
26
1.27
10.9
213
109
16.8
0.90
26
1.25
10.8
207
105
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
59
18.5
0.93
23
1.27
10.9
213
109
17.9
0.89
24
1.26
10.8
211
108
16.5
0.86
25
1.24
10.7
205
104
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
MBh
S/T
DT
KW
AMPS
HI PR
LO PR
63
19.1
0.94
25
1.31
11.0
232
117
18.6
0.90
26
1.30
11.0
230
116
17.2
0.87
26
1.27
10.9
223
112
18.9
0.87
22
1.30
11.0
230
116
18.3
0.83
23
1.29
10.9
227
114
16.9
0.80
24
1.26
10.8
221
111
67
20.1
0.85
23
1.35
11.2
245
127
19.5
0.81
24
1.34
11.1
243
126
18.0
0.78
25
1.31
11.0
235
122
20.2
0.71
20
1.34
11.1
243
126
19.6
0.68
20
1.33
11.1
240
125
18.1
0.65
21
1.30
11.0
233
121
71
21.4
0.69
20
1.39
11.3
256
136
20.8
0.66
21
1.38
11.3
253
134
19.2
0.63
21
1.34
11.2
245
130
21.5
0.53
16
1.38
11.3
253
134
20.9
0.51
16
1.37
11.2
251
133
19.3
0.49
17
1.33
11.1
243
129
59
18.3
1.00
25
1.37
11.3
242
116
17.8
0.96
26
1.36
11.2
240
115
16.4
0.93
27
1.33
11.1
232
111
18.0
0.96
24
1.36
11.2
240
115
17.5
0.92
25
1.35
11.2
237
114
16.2
0.89
25
1.32
11.0
230
110
63
18.7
0.98
25
1.40
11.4
260
123
18.2
0.93
26
1.39
11.3
258
122
16.8
0.90
26
1.36
11.2
250
118
18.4
0.90
23
1.39
11.3
258
122
17.9
0.86
24
1.38
11.3
255
121
16.5
0.83
24
1.35
11.2
248
117
75
67
19.6
0.88
23
1.44
11.5
275
135
19.0
0.84
24
1.43
11.5
272
133
17.6
0.81
25
1.40
11.3
264
129
19.7
0.74
20
1.43
11.5
272
133
19.1
0.70
21
1.42
11.4
270
132
17.6
0.68
21
1.39
11.3
261
128
71
20.9
0.71
20
1.49
11.7
287
143
20.3
0.68
21
1.47
11.7
284
142
18.7
0.66
22
1.44
11.5
275
138
21.0
0.55
16
1.47
11.7
284
142
20.4
0.52
16
1.46
11.6
281
141
18.9
0.51
17
1.43
11.5
273
136
59
17.9
1.00
24
1.45
11.6
275
120
17.4
0.99
26
1.44
11.6
272
119
16.0
0.95
27
1.41
11.5
264
116
17.6
1.00
24
1.44
11.6
272
119
17.1
0.94
25
1.43
11.6
270
118
15.8
0.91
25
1.40
11.4
262
115
18.3
1.00
25
1.48
11.8
296
128
17.7
0.95
26
1.47
11.7
293
127
16.4
0.92
26
1.44
11.6
284
123
18.0
0.93
23
1.47
11.7
293
127
17.5
0.88
24
1.46
11.7
290
126
16.1
0.85
24
1.43
11.5
282
122
19.1
0.90
24
1.53
11.9
313
140
18.6
0.86
24
1.52
11.9
310
139
17.1
0.83
25
1.48
11.7
300
134
19.2
0.76
20
1.52
11.9
310
139
18.7
0.72
21
1.50
11.8
307
137
17.2
0.69
21
1.47
11.7
297
133
20.4
0.73
20
1.57
12.1
326
149
19.8
0.70
21
1.56
12.1
323
148
18.3
0.67
22
1.53
11.9
313
143
20.5
0.56
16
1.56
12.1
323
148
19.9
0.54
16
1.55
12.0
320
146
18.4
0.52
17
1.51
11.9
310
142
17.5
1.00
24
1.52
12.0
313
127
17.0
1.00
26
1.51
11.9
310
125
15.7
0.98
27
1.48
11.8
301
122
17.2
1.00
23
1.51
11.9
310
125
16.7
0.97
25
1.50
11.9
307
124
15.4
0.94
25
1.47
11.8
298
120
17.8
1.00
24
1.55
12.1
337
135
17.3
0.99
26
1.54
12.1
334
133
16.0
0.95
27
1.51
11.9
324
129
17.5
0.96
23
1.54
12.1
334
133
17.0
0.91
24
1.53
12.0
331
132
15.7
0.88
24
1.50
11.9
321
128
18.7
0.93
24
1.60
12.3
356
147
18.1
0.89
25
1.59
12.3
353
145
16.7
0.86
25
1.55
12.1
342
141
18.2
0.74
21
1.58
12.2
349
144
16.8
0.72
21
1.54
12.0
339
140
18.7
0.78
20
1.59
12.3
353
145
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
19.9
0.76
21
1.65
12.5
371
156
19.3
0.72
21
1.64
12.5
368
155
17.8
0.70
22
1.60
12.3
357
150
20.0
0.58
16
1.64
12.5
368
155
19.5
0.56
17
1.63
12.4
364
153
18.0
0.54
17
1.59
12.2
353
149
71
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction service valves.
525
600
675
525
600
675
Airflow
65
MODEL: VSX130181B* / CA*F1824*6
59
63
16.9
1.00
23
1.62
12.5
379
141
16.4
1.00
25
1.60
12.4
376
140
15.2
0.99
26
1.57
12.3
364
135
16.7
1.00
23
1.60
12.4
376
140
16.2
0.95
24
1.59
12.4
372
138
14.9
0.91
24
1.55
12.2
361
134
67
17.7
0.97
23
1.67
12.7
401
154
17.2
0.92
24
1.65
12.6
397
152
15.9
0.89
25
1.61
12.4
385
148
17.8
0.81
20
1.65
12.6
397
152
17.3
0.77
20
1.64
12.6
393
151
16.0
0.74
21
1.60
12.4
381
146
71
18.9
0.79
20
1.72
12.9
418
164
18.4
0.75
21
1.71
12.8
414
162
16.9
0.72
21
1.66
12.7
401
158
19.0
0.60
16
1.71
12.8
414
162
18.5
0.58
16
1.69
12.8
410
161
17.1
0.56
17
1.65
12.6
397
156
59
15.4
1.00
21
1.63
12.7
390
137
14.9
1.00
23
1.62
12.6
386
136
13.8
1.00
24
1.58
12.4
374
132
15.1
1.00
21
1.62
12.6
386
136
14.7
1.00
22
1.61
12.6
382
134
13.5
0.98
23
1.57
12.4
370
130
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
16.6
1.00
23
1.58
12.3
353
133
16.1
1.00
25
1.57
12.3
349
131
14.9
1.00
26
1.53
12.1
339
127
16.3
1.00
22
1.57
12.3
349
131
15.8
1.00
24
1.56
12.2
346
130
14.6
0.97
25
1.52
12.1
335
126
105
63
15.7
1.00
21
1.67
12.8
419
146
15.2
1.00
23
1.66
12.8
415
144
14.0
0.99
24
1.62
12.6
403
140
15.4
1.00
21
1.66
12.8
415
144
15.0
0.96
22
1.64
12.7
411
143
13.8
0.92
22
1.60
12.5
399
139
67
16.4
0.98
22
1.72
13.0
443
159
15.9
0.93
23
1.71
13.0
438
158
14.7
0.90
23
1.67
12.8
425
153
16.5
0.82
18
1.71
13.0
438
158
16.0
0.78
19
1.69
12.9
434
156
14.8
0.75
19
1.65
12.7
421
151
115
17.5
0.79
19
1.78
13.3
462
170
17.0
0.75
20
1.76
13.2
457
168
15.7
0.73
20
1.72
13.0
443
163
17.6
0.61
15
1.76
13.2
457
168
17.1
0.58
15
1.75
13.1
453
166
15.8
0.56
16
1.71
13.0
439
161
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130181C*/VSX130181B*
29
30
75
70
IDB*
23.7
0.58
16
1.73
6.0
232
110
24.4
0.61
15
1.74
6.0
234
111
22.1
0.69
20
1.71
5.9
227
108
23.9
0.71
20
1.74
6.0
234
111
24.6
0.75
19
1.75
6.1
236
112
MBh
22.8
S/T
0.70
Delta T 18
KW
1.71
AMPS 5.8
HI PR 215
LO PR 103
MBh
23.5
S/T
0.73
Delta T 18
KW
1.71
AMPS 5.9
HI PR 217
LO PR 104
MBh
21.4
S/T
0.77
Delta T 22
KW
1.69
AMPS 5.7
HI PR 211
LO PR 101
MBh
23.2
S/T
0.79
Delta T 21
KW
1.71
AMPS 5.9
HI PR 218
LO PR 104
MBh
23.9
S/T
0.83
Delta T 20
KW
1.72
AMPS 5.9
HI PR 220
LO PR 105
800
900
700
800
900
26.7
0.56
15
1.79
6.3
250
122
25.9
0.54
16
1.78
6.2
247
121
23.9
0.52
16
1.75
6.1
240
118
26.7
0.42
12
1.78
6.2
247
121
25.9
0.40
12
1.77
6.2
245
120
67
23.9
0.39
12
1.74
6.0
237
116
28.6
0.36
11
1.83
6.5
260
130
27.8
0.35
11
1.82
6.5
258
129
25.6
0.33
11
1.79
6.3
250
125
-
-
71
-
23.4
0.86
21
1.82
6.4
247
111
22.7
0.82
21
1.81
6.4
244
110
20.9
0.79
22
1.78
6.2
237
107
23.0
0.76
18
1.81
6.4
244
110
22.3
0.72
19
1.80
6.3
242
109
59
20.6
0.70
19
1.77
6.1
234
106
24.1
0.77
19
1.85
6.6
265
119
23.4
0.74
20
1.84
6.5
263
117
21.6
0.71
20
1.80
6.3
255
114
23.8
0.63
15
1.84
6.5
263
117
23.1
0.61
16
1.82
6.5
260
116
63
21.3
0.58
16
1.79
6.3
252
113
75
26.0
0.58
16
1.89
6.8
280
129
25.3
0.56
16
1.88
6.7
277
128
23.3
0.54
16
1.84
6.6
269
124
26.1
0.44
12
1.88
6.7
277
128
25.3
0.42
12
1.87
6.7
275
127
67
23.4
0.40
12
1.83
6.5
266
123
27.9
0.38
11
1.93
7.1
292
138
27.1
0.36
11
1.92
7.0
289
136
25.0
0.35
11
1.89
6.8
281
132
-
-
71
-
22.8
0.89
21
1.90
7.0
280
116
22.1
0.84
21
1.89
6.9
278
115
20.4
0.81
22
1.86
6.7
269
111
22.4
0.78
18
1.89
6.9
278
115
21.8
0.74
19
1.88
6.9
275
114
59
20.1
0.72
19
1.84
6.7
267
110
23.5
0.79
19
1.93
7.2
302
123
22.8
0.76
20
1.92
7.1
299
122
21.0
0.73
20
1.88
6.9
290
118
23.2
0.65
15
1.92
7.1
299
122
22.6
0.62
16
1.91
7.0
296
121
25.4
0.60
16
1.98
7.4
319
135
24.7
0.57
16
1.97
7.3
315
133
22.8
0.55
16
1.93
7.1
306
129
25.5
0.45
12
1.97
7.3
315
133
24.7
0.43
12
1.95
7.3
312
132
27.3
0.39
11
2.03
7.7
332
143
26.5
0.37
11
2.01
7.6
329
142
24.4
0.35
11
1.98
7.4
319
138
-
-
22.2
0.91
21
1.97
7.5
319
122
21.6
0.87
22
1.96
7.4
316
120
19.9
0.84
22
1.93
7.2
307
117
21.9
0.80
18
1.96
7.4
316
120
21.2
0.77
19
1.95
7.3
313
119
22.2
0.57
17
2.00
7.6
348
136
24.1
0.59
16
2.04
7.8
359
140
24.8
0.62
16
2.06
7.9
363
141
22.2
0.78
20
1.99
7.6
340
128
22.9
0.82
19
2.01
7.6
344
129
24.8
0.47
12
2.04
7.8
359
140
24.1
0.44
12
2.03
7.8
356
138
20.5
0.75
20
1.96
7.4
330
124
22.7
0.67
16
1.99
7.6
340
128
22.0
0.64
16
1.98
7.5
337
127
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
20.8 22.8
19.6
20.3
22.3
0.60 0.41
0.74
0.62
0.43
16
12
19
16
13
1.87 1.92
1.91
1.94
1.99
6.8
7.1
7.1
7.3
7.5
287
303
304
327
345
117
128
116
123
134
26.6
0.40
11
2.11
8.2
378
150
25.8
0.38
11
2.09
8.1
375
149
23.8
0.37
11
2.05
7.9
363
145
-
-
71
-
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction service valves.
700
63
21.8
0.56
16
1.70
5.8
225
107
59
MBh
21.1
S/T
0.67
Delta T 19
KW
1.68
AMPS 5.7
HI PR 209
LO PR 100
Airflow
65
MODEL: GSX130241B* / CA*F1824*6B*
21.8
0.85
19
2.07
8.1
387
136
21.1
0.81
20
2.06
8.1
383
134
19.5
0.78
20
2.02
7.8
371
130
21.5
0.70
15
2.06
8.1
383
134
20.9
0.66
16
2.04
8.0
379
133
63
19.3
0.64
16
2.01
7.8
368
129
23.6
0.64
15
2.12
8.4
408
148
22.9
0.61
16
2.11
8.3
404
147
21.1
0.59
16
2.07
8.1
392
142
23.6
0.48
12
2.11
8.3
404
147
22.9
0.46
12
2.09
8.3
400
145
67
21.1
0.44
12
2.05
8.0
388
141
25.3
0.41
11
2.18
8.7
426
158
24.5
0.39
11
2.16
8.6
422
156
22.7
0.38
11
2.12
8.4
409
151
-
-
71
-
19.6
0.96
19
2.09
8.4
397
132
19.0
0.91
20
2.08
8.3
393
131
17.5
0.88
20
2.04
8.1
381
127
19.3
0.84
17
2.08
8.3
393
131
18.7
0.80
17
2.06
8.3
389
129
59
17.3
0.77
18
2.02
8.0
377
125
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
21.1
0.95
20
2.04
7.9
359
127
20.5
0.90
21
2.02
7.9
356
126
18.9
0.87
22
1.99
7.7
345
122
20.8
0.83
18
2.02
7.9
356
126
20.2
0.80
18
2.01
7.8
352
125
59
18.6
0.77
19
1.97
7.6
342
121
105
20.2
0.86
18
2.13
8.6
427
140
19.6
0.82
18
2.11
8.5
423
139
18.1
0.79
19
2.07
8.3
410
135
20.0
0.70
14
2.11
8.5
423
139
19.4
0.67
15
2.10
8.5
419
137
63
17.9
0.65
15
2.06
8.2
406
133
21.8
0.65
14
2.18
8.9
451
153
21.2
0.62
15
2.17
8.8
447
152
19.6
0.60
15
2.12
8.6
433
147
21.9
0.49
11
2.16
8.8
446
152
21.2
0.46
11
2.15
8.7
442
150
67
19.6
0.45
12
2.11
8.5
429
146
115
23.4
0.42
10
2.24
9.3
470
163
22.7
0.40
10
2.22
9.2
466
161
21.0
0.38
11
2.18
8.9
452
157
-
-
71
-
COOLING OPERATION
COOLING PERFORMANCE DATA GSX130241B*/VSX130241A*
85
80
IDB*
63
22.3
0.79
23
1.72
5.9
229
109
24.1
0.82
23
1.75
6.1
236
112
24.9
0.86
22
1.76
6.1
239
113
22.6
0.85
25
1.73
6.0
232
110
24.5
0.88
25
1.76
6.1
239
113
59
21.8
0.84
24
1.70
5.8
213
102
23.6
0.87
24
1.72
5.9
220
105
24.3
0.91
23
1.73
6.0
222
107
MBh
22.2
S/T
0.88
Delta T 26
KW
1.70
AMPS 5.8
HI PR 215
LO PR 103
MBh
24.0
S/T
0.91
Delta T 25
KW
1.73
AMPS 6.0
HI PR 222
LO PR 107
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
25.7
0.80
23
1.80
6.3
252
124
23.7
0.77
24
1.77
6.2
245
120
67
23.8
0.64
20
1.76
6.1
242
119
25.8
0.67
20
1.79
6.3
250
123
26.6
0.70
19
1.80
6.3
252
124
27.4
0.65
20
1.84
6.6
263
132
25.3
0.62
21
1.81
6.4
255
128
71
25.5
0.48
16
1.80
6.3
253
127
27.6
0.50
16
1.83
6.5
260
130
28.4
0.52
15
1.84
6.6
263
132
23.5
0.95
26
1.83
6.5
249
113
21.7
0.91
26
1.80
6.3
242
109
59
21.3
0.87
24
1.79
6.3
239
108
23.1
0.90
24
1.82
6.4
247
111
23.8
0.95
23
1.83
6.5
249
113
23.9
0.91
25
1.86
6.6
268
120
22.1
0.88
26
1.82
6.5
260
116
63
21.8
0.82
23
1.81
6.4
257
115
23.6
0.85
23
1.85
6.6
265
119
24.3
0.89
22
1.86
6.6
268
120
75
25.1
0.82
24
1.90
6.9
283
131
23.1
0.80
24
1.87
6.7
274
127
67
23.3
0.67
20
1.86
6.6
272
126
25.2
0.69
20
1.89
6.8
280
129
26.0
0.72
19
1.90
6.9
283
131
26.8
0.67
21
1.95
7.1
295
139
24.7
0.65
21
1.91
6.9
286
135
71
24.9
0.50
16
1.90
6.9
283
134
26.9
0.52
16
1.93
7.1
292
138
27.7
0.54
15
1.95
7.1
295
139
22.9
0.97
26
1.91
7.0
283
117
21.2
0.94
26
1.88
6.9
275
113
59
20.8
0.89
24
1.87
6.8
272
112
22.5
0.93
24
1.90
7.0
280
116
23.2
1.00
24
1.91
7.0
283
117
24.5
0.85
24
1.99
7.5
322
136
22.6
0.82
24
1.95
7.3
312
132
26.1
0.69
21
2.04
7.7
336
145
24.1
0.66
21
2.00
7.5
326
140
24.1 25.2 26.9
0.98 0.89 0.72
24
23
20
1.96 2.00 2.05
7.3
7.5
7.8
308
325
339
126
137
146
Rating Conditions
23.4
0.94
25
1.94
7.2
305
124
21.6
0.90
26
1.91
7.0
296
121
23.0
1.00
24
2.00
7.6
326
124
22.4
1.00
26
1.99
7.5
323
123
20.6
0.97
26
1.95
7.3
313
119
23.5
1.00
24
2.03
7.8
351
132
22.8
0.97
25
2.02
7.7
347
131
21.0
0.93
26
1.98
7.5
337
127
24.6
0.92
23
2.08
8.0
370
144
23.9
0.87
24
2.07
8.0
367
143
22.0
0.84
24
2.03
7.8
356
138
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
21.3 22.7 24.3 20.3
20.7
22.2
0.84 0.68 0.51 0.92
0.86
0.70
23
20
16
25
24
20
1.90 1.94 1.99 1.94
1.97
2.02
7.0
7.2
7.5
7.3
7.4
7.7
293
309
322
310
333
352
120
130
139
118
126
137
23.0 24.6 26.3 22.0
22.5
24.0
0.87 0.71 0.53 0.96
0.90
0.73
20
23
20
16
24
23
2.06
1.93 1.98 2.03 1.97
2.01
7.2
7.4
7.7
7.5
7.6
7.9
302
319
332
319
344
363
123
135
143
122
129
141
23.7 25.3 27.1 22.6
23.1
24.7
0.91 0.74 0.55 1.00
0.94
0.77
22
19
15
23
22
19
1.94 1.99 2.04 1.99
2.02
2.07
7.2
7.5
7.7
7.5
7.7
8.0
305
322
336
323
347
367
124
136
145
123
131
143
26.2
0.74
20
2.14
8.4
386
154
25.5
0.71
21
2.12
8.3
382
152
23.5
0.68
21
2.08
8.0
371
147
71
23.7
0.53
16
2.07
8.0
367
146
25.7
0.55
16
2.11
8.2
379
150
26.4
0.57
15
2.12
8.3
382
152
EXPANDED PERFORMANCE DATA
MBh
24.8 25.2 26.4 28.2 24.2 24.7 25.8 27.6 23.6
S/T
0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00
Delta T 24
24
23
20
25
24
23
20
24
900
KW
1.74 1.77 1.81 1.85 1.84 1.87 1.91 1.96 1.92
AMPS 6.1
6.2
6.4
6.6
6.5
6.7
6.9
7.2
7.1
HI PR 224
241
255
266
251
271
286
298
286
LO PR 108
114
125
133
114
121
132
141
118
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction service valves.
800
700
900
800
700
Airflow
65
MODEL: GSX130241B* / CA*F1824*6B*
21.7
1.00
25
2.08
8.2
390
137
20.0
0.97
25
2.04
8.0
379
133
63
19.7
0.90
23
2.03
7.9
375
132
21.3
0.93
23
2.07
8.1
387
136
22.0
1.00
22
2.08
8.2
390
137
22.7
0.91
24
2.14
8.5
412
150
20.9
0.87
24
2.09
8.3
400
145
67
21.0
0.73
20
2.08
8.2
396
144
22.8
0.76
20
2.12
8.4
408
148
23.5
0.79
19
2.14
8.5
412
150
24.2
0.74
20
2.19
8.8
430
159
22.3
0.71
21
2.15
8.6
417
155
71
22.5
0.55
16
2.13
8.5
413
153
24.4
0.57
16
2.18
8.7
426
158
25.1
0.59
15
2.19
8.8
430
159
19.7
1.00
23
2.10
8.5
401
133
18.2
1.00
24
2.06
8.3
389
129
59
17.9
0.97
23
2.05
8.2
385
128
19.3
1.00
22
2.09
8.4
397
132
19.9
1.00
20
2.10
8.5
401
133
20.1
1.00
23
2.14
8.7
431
142
18.5
0.98
24
2.10
8.5
419
137
63
18.2
0.91
22
2.08
8.4
414
136
19.8
0.94
21
2.13
8.6
427
140
20.4
1.00
21
2.14
8.7
431
142
21.6
0.96
21
2.21
9.1
460
156
21.0
0.91
22
2.19
9.0
456
155
19.4
0.88
22
2.15
8.7
442
150
67
19.5
0.74
19
2.14
8.7
438
149
21.1
0.76
19
2.18
8.9
451
153
21.8
0.80
18
2.19
9.0
456
155
115
21.9 22.3 23.4 24.9 20.3 20.7
1.00 1.00 0.95 0.77 1.00 1.00
22
23
23
20
21
21
2.06 2.10 2.15 2.21 2.12 2.15
8.1
8.3
8.6
8.9
8.6
8.8
366
394
416
434
405
436
143
130
138
151
161
135
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
21.2
1.00
24
2.05
8.0
363
129
19.6
1.00
26
2.01
7.8
352
125
59
19.3
0.96
24
2.00
7.7
348
124
20.9
0.99
24
2.04
7.9
359
127
21.5
1.00
22
2.05
8.0
363
129
105
23.1
0.78
18
2.27
9.4
480
166
22.4
0.74
19
2.25
9.3
475
165
20.7
0.71
19
2.21
9.1
461
160
71
20.8
0.55
15
2.19
9.0
456
158
22.6
0.57
15
2.24
9.3
470
163
23.3
0.60
14
2.25
9.3
475
165
COOLING OPERATION
COOLING PERFORMANCE DATA GSX130241B*/VSX130241A*
31
32
75
70
IDB*
28.8
0.63
15
2.04
7.2
256
113
26.1
0.70
19
1.99
7.1
248
110
28.3
0.73
19
2.04
7.2
256
113
MBh
27.8
S/T
0.75
Delta T 17
KW
2.00
AMPS 7.1
HI PR 237
LO PR 106
MBh
25.4
S/T
0.79
Delta T 21
KW
1.95
AMPS 6.9
HI PR 230
LO PR 103
MBh
27.5
S/T
0.82
Delta T 21
KW
2.00
AMPS 7.1
HI PR 238
LO PR 106
1125
875
30.6
0.55
16
2.10
7.5
270
124
28.3
0.53
16
2.05
7.3
262
120
31.6
0.44
11
2.10
7.5
270
124
67
28.3
0.40
12
2.03
7.2
259
119
30.7
0.42
12
2.08
7.4
267
122
32.9
0.36
11
2.16
7.8
282
132
30.3
0.34
11
2.11
7.6
273
128
-
71
-
26.8
0.85
21
2.14
7.7
267
112
24.8
0.82
21
2.09
7.4
259
109
27.2
0.78
17
2.14
7.7
266
112
59
24.4
0.72
18
2.08
7.4
256
108
26.4
0.74
18
2.13
7.6
264
111
27.6
0.76
19
2.19
7.8
287
120
25.5
0.73
20
2.14
7.6
278
116
28.2
0.65
15
2.19
7.8
287
120
63
25.2
0.60
16
2.12
7.6
275
115
27.4
0.62
16
2.17
7.8
284
118
75
29.9
0.57
16
2.25
8.1
303
131
27.6
0.55
16
2.20
7.9
294
127
30.9
0.45
11
2.25
8.1
303
131
67
27.7
0.42
12
2.18
7.8
291
125
30.0
0.43
12
2.24
8.0
300
129
32.1
0.37
11
2.32
8.4
316
139
29.6
0.36
11
2.27
8.2
306
135
-
71
-
26.2
0.87
21
2.27
8.3
303
117
24.2
0.84
21
2.22
8.1
294
113
26.5
0.80
17
2.27
8.3
303
117
59
23.8
0.74
18
2.20
8.0
291
112
25.8
0.76
18
2.25
8.2
300
116
29.2
0.59
16
2.39
8.8
344
136
26.9
0.57
16
2.33
8.6
334
132
30.1
0.46
11
2.39
8.8
344
136
31.3
0.38
11
2.47
9.1
359
145
28.9
0.36
11
2.41
8.9
349
140
-
27.8 30.1 32.3
0.81 0.62 0.40
18
15
10
2.34 2.41 2.49
8.6
8.9
9.2
329
348
363
126
137
146
(TVA) conditions
27.0
0.78
19
2.32
8.5
326
124
24.9
0.75
20
2.26
8.3
316
121
27.5
0.67
15
2.32
8.5
326
124
26.3
0.94
20
2.40
9.0
349
124
25.6
0.90
21
2.39
8.9
345
123
23.6
0.86
21
2.33
8.6
335
119
25.9
0.83
17
2.39
8.9
345
123
28.5
0.61
16
2.51
9.4
392
143
29.3
0.64
15
2.53
9.5
396
144
27.1
0.84
19
2.46
9.2
375
132
26.3
0.58
16
2.45
9.2
381
138
29.4
0.48
11
2.51
9.4
392
143
24.3
0.77
20
2.38
8.9
360
127
26.3
0.80
19
2.44
9.1
372
131
26.8
0.69
15
2.44
9.1
371
131
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
24.6 27.0
23.2
24.0
26.3
0.61 0.43
0.76
0.63
0.44
16
12
19
16
12
2.25 2.32
2.31
2.36
2.43
8.2
8.5
8.6
8.8
9.1
313
331
332
357
377
119
130
118
125
137
26.7 29.3
25.1
26.1
28.5
0.64 0.44
0.79
0.66
0.46
16
12
18
16
12
2.30 2.37
2.37
2.42
2.49
8.4
8.7
8.8
9.0
9.3
323
341
342
368
388
123
134
122
129
141
31.5
0.41
11
2.61
9.9
413
153
30.6
0.39
11
2.59
9.8
409
152
28.2
0.38
11
2.53
9.5
397
147
-
71
-
EXPANDED PERFORMANCE DATA
MBh
28.3 29.1 31.5 33.9 27.6 28.5 30.8 33.1 27.0
S/T
0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91
Delta T 20
18
15
10
20
18
15
10
20
1125
KW
2.01 2.05 2.11 2.18 2.16 2.20 2.27 2.34 2.29
AMPS 7.1
7.3
7.6
7.8
7.7
7.9
8.2
8.5
8.4
HI PR 240
258
273
284
269
290
306
319
306
LO PR 107
114
125
133
114
121
132
140
118
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction service valves.
1000
1000
875
63
25.8
0.58
16
1.98
7.0
245
109
28.0
0.60
15
2.02
7.2
253
112
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
59
24.9
0.69
18
1.94
6.8
228
102
27.0
0.72
18
1.98
7.0
235
105
Airflow
65
MODEL: GSX130301B* / CA*F3030*6B*
25.0
0.83
19
2.53
9.7
418
137
23.1
0.80
19
2.47
9.4
405
133
25.5
0.72
15
2.53
9.7
418
137
63
22.8
0.66
16
2.45
9.3
401
131
24.7
0.68
16
2.51
9.6
414
135
27.1
0.63
16
2.62
10.0
441
149
25.0
0.61
16
2.55
9.7
428
145
27.9
0.50
11
2.62
10.0
441
149
67
25.0
0.46
12
2.53
9.7
424
143
27.1
0.47
12
2.59
9.9
437
148
29.0
0.40
11
2.70
10.4
460
159
26.8
0.39
11
2.63
10.1
447
154
-
71
-
22.5
0.94
19
2.57
10.0
429
133
20.8
0.90
20
2.50
9.7
416
129
22.8
0.86
16
2.56
10.0
429
133
59
20.4
0.80
17
2.48
9.7
412
128
22.1
0.82
17
2.54
9.9
425
132
23.2
0.84
18
2.62
10.3
462
142
21.4
0.81
18
2.56
10.0
448
137
23.6
0.72
14
2.62
10.3
462
142
63
21.2
0.66
15
2.54
9.9
443
136
22.9
0.69
15
2.60
10.2
457
140
25.8
0.67
14
2.73
10.7
493
156
25.1
0.63
15
2.70
10.6
488
155
23.1
0.61
15
2.64
10.3
473
150
25.9
0.50
11
2.70
10.6
488
155
67
23.2
0.46
11
2.62
10.2
468
148
25.1
0.48
11
2.68
10.5
483
153
115
25.0 25.8 27.9 29.9 23.2 23.9
0.97 0.87 0.66 0.42 0.98 0.88
20
18
15
10
19
17
2.50 2.56 2.64 2.72 2.59 2.64
9.6
9.8
10.1 10.5 10.1 10.4
392
422
446
465
433
466
130
138
151
161
134
143
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
24.3
0.93
21
2.48
9.5
388
129
22.4
0.90
21
2.42
9.2
377
125
24.6
0.86
17
2.48
9.5
388
129
59
22.0
0.79
18
2.40
9.1
373
124
23.9
0.82
18
2.46
9.4
384
127
105
27.7
0.43
10
2.82
11.1
514
166
26.9
0.41
10
2.79
11.0
509
165
24.8
0.39
10
2.72
10.7
493
160
-
71
-
CO OLING OPERATION
COOLING PERFORMANCE DATA GSX130301B*/VSX130301A*
85
80
IDB*
28.6
0.84
22
2.05
7.3
258
114
29.4
0.88
21
2.07
7.4
261
116
28.0
0.90
23
2.01
7.1
240
107
28.8
0.94
22
2.03
7.2
242
109
26.3
0.91
25
1.98
7.0
235
105
28.5
0.94
25
2.03
7.2
242
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
26.8
0.87
25
2.02
7.2
253
112
29.0
0.91
24
2.07
7.4
261
116
63
26.4
0.81
22
2.01
7.1
250
111
59
MBh
25.8
S/T
0.86
Delta T 23
KW
1.97
AMPS 7.0
HI PR 233
LO PR 104
28.0
0.79
23
2.08
7.4
267
122
30.4
0.82
23
2.13
7.6
275
126
30.5
0.68
19
2.12
7.6
273
125
31.4
0.72
18
2.13
7.6
275
126
67
28.2
0.66
20
2.07
7.3
264
121
29.9
0.64
20
2.15
7.7
279
130
32.4
0.66
20
2.20
7.9
287
134
32.6
0.51
15
2.18
7.8
284
133
33.6
0.54
15
2.20
7.9
287
134
71
30.1
0.49
16
2.13
7.6
276
129
25.7
0.94
25
2.13
7.6
264
111
27.8
0.97
25
2.18
7.8
272
115
27.3
0.93
23
2.16
7.7
269
114
28.1
1.00
23
2.18
7.8
272
115
59
25.2
0.90
24
2.11
7.5
261
110
26.1
0.91
25
2.17
7.8
284
118
28.3
0.94
24
2.22
8.0
293
122
27.9
0.87
22
2.20
7.9
290
121
28.7
0.91
21
2.22
8.0
293
122
63
25.8
0.84
23
2.15
7.7
281
117
75
27.4
0.82
24
2.24
8.0
300
129
29.7
0.85
23
2.29
8.2
309
133
29.8
0.71
19
2.27
8.2
306
132
30.7
0.74
19
2.29
8.2
309
133
67
27.5
0.68
20
2.22
7.9
297
128
29.2
0.66
20
2.31
8.3
313
138
31.7
0.69
20
2.36
8.6
322
142
31.9
0.53
16
2.34
8.5
319
140
32.8
0.56
15
2.36
8.6
322
142
71
29.4
0.51
16
2.29
8.2
310
136
25.0
0.96
25
2.25
8.2
300
116
27.1
1.00
25
2.31
8.5
309
119
26.7
0.95
23
2.29
8.4
306
118
27.5
1.00
22
2.31
8.5
309
119
59
24.6
0.92
24
2.24
8.2
297
114
26.7
0.84
24
2.37
8.7
341
134
29.0
0.87
23
2.43
9.0
351
138
29.1
0.73
19
2.41
8.9
348
137
30.0
0.76
19
2.43
9.0
351
138
28.5
0.68
20
2.45
9.0
356
143
30.9
0.71
20
2.51
9.3
367
147
31.1
0.54
16
2.49
9.2
363
146
32.1
0.57
15
2.51
9.3
367
147
28.5 29.8 31.8
1.00 0.91 0.74
23
22
19
2.37 2.45 2.53
8.8
9.0
9.4
336
355
370
128
140
149
Rating Conditions
25.5
0.93
25
2.30
8.4
323
123
27.7
0.96
24
2.36
8.7
333
127
27.2
0.89
22
2.34
8.6
330
126
28.1
0.94
21
2.36
8.7
333
127
27.3
1.00
22
2.44
9.1
356
126
24.4
0.99
25
2.37
8.8
342
121
26.5
1.00
24
2.42
9.1
352
125
26.0
0.98
23
2.40
9.0
349
124
26.8
1.00
22
2.42
9.1
352
125
27.8
1.00
23
2.49
9.4
383
135
24.9
0.96
25
2.42
9.0
368
129
27.0
0.99
25
2.48
9.3
379
133
26.6
0.92
23
2.46
9.2
375
132
27.4
0.97
22
2.48
9.3
379
133
29.1
0.94
22
2.57
9.7
404
147
26.1
0.86
24
2.49
9.3
388
141
28.3
0.90
23
2.55
9.6
400
145
28.4
0.75
20
2.53
9.5
396
144
29.3
0.79
19
2.55
9.6
400
145
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
25.1 26.9 28.7 24.0
24.5
26.2
0.86 0.70 0.52 0.95
0.89
0.72
23
20
16
24
23
20
2.28 2.35 2.43 2.35
2.40
2.47
8.4
8.6
9.0
8.7
8.9
9.2
320
338
352
338
364
384
122
133
142
120
128
140
31.1
0.76
19
2.66
10.0
422
156
27.8
0.70
21
2.57
9.7
405
150
30.1
0.73
20
2.64
10.0
417
155
30.4
0.56
16
2.61
9.9
413
153
31.3
0.59
15
2.64
10.0
417
155
71
28.0
0.54
16
2.55
9.6
401
149
EXPANDED PERFORMANCE DATA
MBh
29.3 29.9 31.3 33.4 28.6 29.2 30.6 32.6 27.9
S/T
0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00
Delta T 24
23
22
19
23
23
22
19
23
1125
KW
2.04 2.08 2.15 2.21 2.19 2.24 2.31 2.38 2.33
AMPS 7.3
7.4
7.7
8.0
7.9
8.1
8.3
8.6
8.5
HI PR 245
263
278
290
275
296
312
326
312
LO PR 110
117
127
136
116
123
135
143
120
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction service valves.
1000
875
1125
1000
875
Airflow
65
MODEL: GSX130301B* / CA*F3030*6B*
23.7
0.99
25
2.51
9.6
414
135
25.6
1.00
24
2.58
9.9
426
140
25.3
0.96
22
2.56
9.8
422
138
26.0
1.00
21
2.58
9.9
426
140
63
23.3
0.92
23
2.49
9.5
410
134
24.8
0.90
23
2.59
9.9
437
148
26.8
0.93
23
2.66
10.2
450
152
27.0
0.78
19
2.64
10.1
446
151
27.8
0.82
19
2.66
10.2
450
152
67
24.9
0.75
20
2.57
9.8
432
146
26.4
0.73
20
2.68
10.3
456
157
28.6
0.76
20
2.74
10.6
470
162
28.8
0.58
15
2.72
10.5
465
161
29.7
0.61
15
2.74
10.6
470
162
71
26.6
0.56
16
2.66
10.2
451
156
21.5
1.00
23
2.54
9.9
425
132
23.3
1.00
21
2.61
10.2
438
136
22.9
1.00
21
2.59
10.1
433
134
23.6
1.00
19
2.61
10.2
438
136
59
21.1
0.99
22
2.52
9.8
420
130
21.9
1.00
23
2.60
10.2
457
140
23.7
1.00
22
2.66
10.5
471
144
23.4
0.96
21
2.64
10.4
466
143
24.1
1.00
20
2.66
10.5
471
144
63
21.6
0.93
21
2.58
10.1
452
139
25.6
0.98
21
2.77
10.9
503
159
23.0
0.91
22
2.68
10.5
483
153
24.9
0.94
21
2.75
10.8
498
158
25.0
0.78
18
2.73
10.7
493
156
25.7
0.82
17
2.75
10.8
498
158
67
23.1
0.76
18
2.66
10.4
478
151
115
25.9 26.4 27.7 29.5 24.0 24.5
1.00 1.00 0.98 0.79 1.00 1.00
21
22
22
19
20
20
2.54 2.60 2.68 2.77 2.63 2.69
9.7
10.0 10.3 10.7 10.3 10.6
400
431
455
474
442
476
133
141
154
164
137
146
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
23.2
1.00
24
2.46
9.4
384
127
25.1
1.00
23
2.52
9.6
396
131
24.7
1.00
23
2.50
9.6
392
130
25.5
1.00
21
2.52
9.6
396
131
59
22.8
0.98
24
2.44
9.3
381
126
105
27.3
0.80
18
2.86
11.3
524
170
24.5
0.73
19
2.77
10.9
503
163
26.5
0.76
19
2.84
11.2
519
168
26.7
0.59
14
2.82
11.1
514
166
27.5
0.62
14
2.84
11.2
519
168
71
24.7
0.57
15
2.75
10.8
498
161
COOLING OPERATION
COOLING PERFORMANCE DATA GSX130301B*/VSX130301A*
33
34
75
70
IDB*
34.2
0.82
22
2.47
9.1
223
103
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1200
35.3
0.73
20
2.52
9.3
240
110
32.5
0.71
20
2.46
9.0
233
107
38.2
0.56
16
2.60
9.6
254
120
35.2
0.54
17
2.54
9.3
246
117
38.2
0.42
12
2.58
9.5
251
119
39.4
0.44
12
2.60
9.6
254
120
41.0
0.36
11
2.68
10.0
265
128
37.8
0.34
11
2.62
9.7
257
124
-
71
-
33.5
0.85
22
2.65
9.8
251
109
30.9
0.82
22
2.59
9.5
243
106
32.9
0.75
19
2.63
9.7
248
108
33.9
0.78
18
2.65
9.8
250
109
59
30.4
0.72
19
2.57
9.4
241
105
34.4
0.76
20
2.71
10.0
270
116
31.8
0.73
20
2.65
9.8
262
113
34.1
0.62
16
2.69
10.0
267
115
35.1
0.65
16
2.71
10.0
270
116
63
31.5
0.60
17
2.63
9.7
259
112
37.3
0.58
16
2.79
10.4
285
127
34.4
0.55
17
2.73
10.1
276
123
37.4
0.43
12
2.77
10.3
282
126
38.5
0.45
12
2.79
10.4
285
127
67
34.5
0.42
13
2.71
10.0
273
122
40.0
0.37
11
2.88
10.8
297
135
36.9
0.36
12
2.81
10.5
288
131
-
71
-
32.7
0.87
22
2.82
10.7
285
114
30.1
0.84
22
2.75
10.4
276
110
32.1
0.77
19
2.79
10.6
282
112
33.1
0.80
18
2.82
10.7
285
114
59
29.6
0.74
19
2.73
10.3
274
109
33.6
0.78
20
2.88
10.9
307
121
31.0
0.75
20
2.81
10.6
297
117
33.3
0.64
16
2.85
10.8
304
120
34.3
0.67
16
2.88
10.9
307
121
36.4
0.59
16
2.97
11.3
324
132
33.6
0.57
17
2.89
11.0
314
128
36.5
0.44
12
2.94
11.2
321
131
37.6
0.47
12
2.97
11.3
324
132
36.1
0.37
12
2.99
11.4
328
136
29.4
0.87
22
2.89
11.1
315
116
31.3
0.79
19
2.93
11.3
321
118
32.3
0.83
18
2.96
11.4
324
119
32.8
0.94
21
2.98
11.5
328
121
31.6
0.79
22
2.41
8.8
217
100
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
34.9
0.60
16
2.50
9.2
238
109
36.0
0.63
15
2.52
9.3
240
110
67
35.3
0.40
12
2.52
9.2
244
115
MBh
35.3 36.3 39.3 42.2 34.5 35.5 38.4 41.2 33.6 34.6 37.5 40.2
S/T
0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.91 0.82 0.62 0.40
Delta T
21
19
16
11
21
19
16
11
21
19
16
11
1350
KW
2.49 2.54 2.62 2.70 2.68 2.73 2.82 2.91 2.84 2.90 2.99 3.09
AMPS
9.1
9.4
9.7
10.0
9.9
10.1 10.5 10.9 10.8 11.0 11.4 11.8
HI PR
226
243
256
267
253
272
288
300
288
310
327
341
LO PR
104
111
121
129
110
117
128
137
115
122
133
142
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction service valves.
33.7
0.72
19
2.45
9.0
221
102
34.7
0.76
18
2.47
9.1
223
103
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
63
32.2
0.58
16
2.44
8.9
231
106
30.3
0.78
21
2.95
11.4
339
123
32.8
0.80
20
3.02
11.7
349
127
33.8
0.84
19
3.05
11.8
353
128
32.5
0.66
16
3.00
11.6
346
126
33.4
0.69
16
3.02
11.7
349
127
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
30.7 33.7
28.9
30.0
0.62 0.43
0.76
0.64
17
13
19
17
2.78 2.87
2.86
2.92
10.5 10.9
11.0
11.3
294
311
312
335
116
127
115
122
31.9
0.90
22
2.96
11.4
325
119
59
31.1
0.70
19
2.40
8.7
214
99
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
75
36.6
0.64
16
3.14
12.2
372
140
35.5
0.61
17
3.12
12.1
369
139
32.8
0.59
17
3.04
11.7
358
134
35.6
0.46
12
3.09
12.0
365
137
36.6
0.48
12
3.12
12.1
369
139
67
32.8
0.44
13
3.02
11.6
354
133
39.3
0.41
11
3.25
12.7
388
149
38.1
0.39
11
3.22
12.5
385
148
35.2
0.38
12
3.14
12.2
373
143
-
71
-
EXPANDED PERFORMANCE DATA
39.1
0.38
11
3.06
11.7
338
141
1050
1350
1200
1050
Airflow
65
MODEL: GSX130361B* / CA*F3036*6C*
31.2
0.83
20
3.15
12.5
393
133
28.8
0.81
20
3.07
12.1
381
129
30.8
0.69
16
3.12
12.3
389
132
31.8
0.72
16
3.15
12.5
393
133
63
28.5
0.66
16
3.04
12.0
377
128
33.7
0.63
16
3.25
12.9
415
145
31.1
0.61
17
3.17
12.5
402
141
33.8
0.48
12
3.22
12.8
411
144
34.8
0.50
12
3.25
12.9
415
145
67
31.2
0.46
13
3.14
12.4
398
139
36.2
0.41
11
3.35
13.4
433
155
33.4
0.39
11
3.27
13.0
420
150
-
71
-
28.0
0.94
20
3.18
12.9
403
129
25.9
0.91
21
3.11
12.5
391
125
27.6
0.83
17
3.16
12.8
399
128
28.4
0.87
17
3.18
12.9
403
129
59
25.4
0.80
18
3.08
12.4
387
124
28.9
0.84
19
3.25
13.2
434
138
26.6
0.81
19
3.17
12.8
421
133
28.6
0.69
15
3.23
13.1
430
136
29.4
0.73
15
3.25
13.2
434
138
63
26.4
0.67
15
3.15
12.7
417
132
32.2
0.67
15
3.39
13.8
463
152
31.2
0.64
15
3.36
13.7
458
150
28.8
0.61
16
3.28
13.3
445
146
31.3
0.48
11
3.33
13.5
454
149
32.2
0.50
11
3.36
13.7
458
150
67
28.9
0.46
12
3.25
13.1
440
144
115
31.2 32.1 34.7 37.3 28.9 29.7
0.98 0.88 0.66 0.43 0.99 0.88
21
19
16
11
19
18
3.10 3.17 3.27 3.38 3.21 3.28
12.3 12.6 13.0 13.5 13.0 13.3
369
397
419
437
407
438
126
134
147
156
131
139
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
30.3
0.93
22
3.08
12.2
365
125
27.9
0.90
22
3.00
11.8
354
121
29.8
0.82
19
3.05
12.0
361
124
30.7
0.86
18
3.08
12.1
365
125
59
27.5
0.79
19
2.98
11.7
351
120
105
34.5
0.43
10
3.50
14.3
483
162
33.5
0.41
11
3.47
14.2
478
160
31.0
0.40
11
3.38
13.8
464
155
-
71
-
COOLING OPERATION
COOLING PERFORMANCE DATA GSX130361B*/VSX130361A*
85
80
IDB*
34.9
0.90
24
2.49
9.1
226
105
35.9
0.94
23
2.51
9.2
228
106
32.7
0.91
26
2.45
9.0
221
102
35.5
0.94
26
2.51
9.2
228
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1200
1350
1050
34.6
0.98
26
2.70
10.0
256
112
32.0
0.94
26
2.63
9.7
248
108
35.1
1.00
24
2.70
10.0
256
112
34.0
0.93
24
2.68
9.9
253
110
59
31.4
0.90
25
2.61
9.6
245
107
35.3
0.94
26
2.75
10.2
275
119
32.6
0.91
26
2.69
10.0
267
115
35.8
0.92
22
2.75
10.2
275
119
34.8
0.87
23
2.73
10.1
272
117
63
32.1
0.84
24
2.67
9.9
264
114
37.0
0.85
24
2.84
10.6
290
130
34.1
0.82
25
2.77
10.3
282
126
38.3
0.75
19
2.84
10.6
290
130
37.2
0.71
20
2.82
10.5
288
128
67
34.3
0.69
21
2.75
10.2
279
124
39.5
0.69
21
2.93
11.0
303
138
36.4
0.67
21
2.86
10.7
294
134
40.9
0.56
16
2.93
11.0
303
138
39.7
0.53
16
2.91
10.9
300
137
71
36.7
0.51
16
2.84
10.6
291
132
33.8
1.00
26
2.86
10.9
291
116
31.2
0.97
26
2.79
10.6
282
112
34.2
1.00
23
2.86
10.9
291
116
33.2
0.96
24
2.84
10.8
288
115
59
30.7
0.92
25
2.77
10.5
279
111
34.5
0.97
26
2.92
11.1
313
123
31.8
0.93
26
2.85
10.8
303
120
35.0
0.94
22
2.92
11.1
313
123
34.0
0.90
23
2.90
11.0
310
122
36.1
0.87
24
3.01
11.5
330
135
33.3
0.84
25
2.94
11.2
320
131
37.4
0.76
19
3.01
11.5
330
135
36.3
0.73
20
2.99
11.4
327
133
35.6
0.68
21
3.04
11.6
334
139
40.0
0.57
16
3.11
11.9
345
143
38.8
0.55
16
3.09
11.8
341
142
30.5
1.00
27
2.93
11.3
321
118
33.4
1.00
23
3.01
11.6
331
122
32.4
0.99
25
2.98
11.5
328
121
34.0
1.00
23
3.03
11.7
334
123
40.4
0.67
21
2.72
10.1
270
131
37.3
0.64
21
2.66
9.9
262
127
41.9
0.54
15
2.72
10.1
270
131
40.7
0.51
16
2.70
10.0
267
129
71
37.5
0.49
16
2.64
9.8
259
125
MBh
36.5 37.2 39.0 41.6 35.7 36.4 38.1 40.6 34.8 35.5 37.2 39.7
S/T
0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.91 0.74
Delta T
25
24
23
20
24
24
23
20
24
24
23
20
1350
KW
2.53 2.58 2.66 2.74 2.72 2.77 2.86 2.95 2.88 2.95 3.04 3.14
AMPS
9.3
9.5
9.9
10.2 10.1 10.3 10.7 11.1 11.0 11.2 11.6 12.1
HI PR
230
248
261
273
258
278
293
306
294
316
334
348
107
113
124
132
113
120
131
139
117
125
136
145
LO PR
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction service valves.
1200
37.9
0.82
24
2.64
9.8
259
123
34.9
0.79
24
2.58
9.5
251
119
39.2
0.72
19
2.64
9.8
259
123
38.1
0.69
20
2.62
9.7
256
121
67
35.1
0.66
20
2.56
9.4
249
118
34.6
1.00
24
3.10
12.0
360
131
33.6
1.00
26
3.07
11.9
356
130
31.0
0.96
26
3.00
11.6
346
126
34.1
0.97
23
3.07
11.9
356
130
33.1
0.93
23
3.05
11.8
353
128
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
31.3 33.5 35.8 29.9
30.6
0.86 0.70 0.53 0.95
0.89
24
21
16
25
24
2.83 2.92 3.01 2.91
2.97
10.7 11.1 11.5 11.2
11.5
300
317
331
318
342
118
129
138
117
124
33.0
1.00
25
3.01
11.6
331
122
36.2
0.91
25
2.56
9.5
245
112
33.4
0.88
26
2.50
9.2
238
109
36.7
0.88
22
2.56
9.5
245
112
35.6
0.84
23
2.54
9.4
243
111
63
32.9
0.81
23
2.48
9.1
235
108
75
36.3
0.94
23
3.20
12.4
380
143
35.2
0.90
24
3.17
12.3
376
141
32.5
0.87
25
3.09
12.0
365
137
35.4
0.75
20
3.14
12.2
373
140
36.5
0.79
20
3.17
12.3
376
141
67
32.7
0.73
21
3.07
11.9
361
136
38.7
0.77
20
3.30
12.9
396
152
37.6
0.73
21
3.27
12.8
392
151
34.7
0.70
21
3.19
12.4
381
146
39.0
0.59
16
3.27
12.8
392
151
37.8
0.56
16
3.25
12.7
389
149
71
34.9
0.54
17
3.17
12.3
377
145
EXPANDED PERFORMANCE DATA
38.5
0.71
21
3.11
11.9
345
143
1050
59
32.2
0.87
24
2.43
8.9
219
101
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
MODEL: GSX130361B* / CA*F3036*6C*
31.9
1.00
24
3.20
12.7
401
136
29.5
1.00
26
3.12
12.3
389
132
32.4
1.00
22
3.20
12.7
401
136
31.5
0.96
23
3.17
12.6
397
134
63
29.1
0.93
24
3.09
12.2
385
130
33.5
0.93
24
3.30
13.1
423
148
30.9
0.90
24
3.22
12.8
411
144
34.6
0.82
19
3.30
13.1
423
148
33.6
0.78
20
3.27
13.0
419
147
67
31.0
0.75
20
3.19
12.6
406
142
35.7
0.76
21
3.41
13.6
441
158
33.0
0.73
21
3.33
13.2
428
153
37.0
0.61
15
3.41
13.6
441
158
36.0
0.58
16
3.38
13.5
437
156
71
33.2
0.56
16
3.30
13.1
424
152
29.0
1.00
22
3.24
13.1
412
132
26.8
1.00
23
3.16
12.8
399
128
29.4
1.00
20
3.24
13.1
412
132
28.5
1.00
22
3.21
13.0
407
131
59
26.3
1.00
23
3.13
12.6
395
127
29.6
1.00
23
3.31
13.5
443
140
27.3
1.00
24
3.23
13.1
430
136
30.0
1.00
20
3.31
13.5
443
140
29.2
0.97
22
3.28
13.3
438
139
63
26.9
0.93
22
3.20
13.0
425
135
31.9
0.99
21
3.44
14.0
472
155
31.0
0.94
22
3.42
13.9
468
153
28.6
0.91
23
3.33
13.5
454
149
32.1
0.83
18
3.42
13.9
468
153
31.2
0.79
19
3.39
13.8
463
152
67
28.8
0.76
19
3.30
13.4
449
147
115
32.3 32.9 34.5 36.8 29.9 30.5
1.00 1.00 0.98 0.80 1.00 1.00
22
22
23
20
20
21
3.16 3.22 3.33 3.44 3.26 3.33
12.5 12.8 13.2 13.8 13.3 13.6
376
405
427
446
416
447
129
137
150
159
133
142
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
31.3
1.00
24
3.13
12.4
372
128
28.9
1.00
25
3.05
12.0
361
124
31.7
1.00
22
3.13
12.4
372
128
30.8
1.00
24
3.11
12.3
369
126
59
28.4
0.99
25
3.03
11.9
358
123
105
34.1
0.80
19
3.56
14.6
493
165
33.1
0.76
19
3.53
14.5
488
163
30.5
0.74
20
3.44
14.0
473
158
34.3
0.62
14
3.53
14.5
488
163
33.3
0.59
15
3.50
14.3
483
162
71
30.7
0.57
15
3.41
13.9
468
157
COOLING OPERATION
COOLING PERFORMANCE DATA GSX130361B*/VSX130361A*
35
36
75
70
IDB*
39.0
0.71
18
2.84
10.9
216
104
40.2
0.75
18
2.87
11.0
218
105
36.6
0.78
21
2.80
10.8
212
102
39.7
0.81
21
2.87
11.0
218
105
40.9
0.85
20
2.89
11.1
220
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1400
1575
1225
1400
1575
42.1
0.76
19
2.94
11.4
237
113
40.8
0.72
19
2.92
11.3
235
112
37.7
0.70
20
2.86
11.0
228
108
41.6
0.62
15
2.92
11.3
235
112
40.4
0.59
16
2.90
11.2
232
111
63
37.3
0.57
16
2.84
10.9
225
107
45.5
0.57
15
3.03
11.8
250
123
44.2
0.55
16
3.01
11.7
248
122
40.8
0.53
16
2.94
11.3
240
118
45.6
0.43
11
3.01
11.7
248
122
44.3
0.41
12
2.98
11.6
245
121
67
40.9
0.40
12
2.92
11.2
238
117
48.9
0.37
11
3.12
12.2
261
131
47.4
0.35
11
3.10
12.1
259
130
43.8
0.34
11
3.03
11.8
251
126
-
-
71
-
39.9
0.88
20
3.09
12.0
247
112
38.7
0.84
21
3.07
11.9
245
111
35.8
0.81
22
3.00
11.6
237
108
39.2
0.77
18
3.07
11.9
245
111
38.1
0.74
18
3.05
11.8
242
110
59
35.2
0.71
19
2.98
11.5
235
106
41.1
0.79
19
3.15
12.3
266
119
39.9
0.75
20
3.13
12.2
263
118
36.8
0.72
20
3.06
11.9
256
114
40.7
0.65
15
3.13
12.2
263
118
39.5
0.62
16
3.11
12.1
261
117
63
36.4
0.59
16
3.04
11.8
253
113
75
44.5
0.60
15
3.25
12.7
281
130
43.2
0.57
16
3.22
12.6
278
129
39.9
0.55
16
3.15
12.2
270
125
44.6
0.45
12
3.22
12.6
278
129
43.3
0.43
12
3.20
12.5
275
127
67
39.9
0.41
12
3.13
12.1
267
124
47.7
0.38
11
3.35
13.2
293
139
46.3
0.37
11
3.32
13.0
290
137
42.8
0.35
11
3.24
12.7
281
133
-
-
71
-
39.0
0.90
21
3.27
13.0
281
116
37.8
0.86
21
3.25
12.9
278
115
34.9
0.83
22
3.17
12.6
270
112
38.3
0.79
18
3.25
12.9
278
115
37.2
0.76
18
3.22
12.8
276
114
59
34.3
0.73
19
3.15
12.5
267
111
40.1
0.81
19
3.34
13.3
303
124
38.9
0.77
20
3.31
13.2
300
123
35.9
0.74
20
3.24
12.9
291
119
39.7
0.66
15
3.31
13.2
300
123
38.5
0.63
16
3.29
13.1
297
121
43.4
0.61
15
3.44
13.8
320
135
42.2
0.58
16
3.41
13.6
316
134
38.9
0.56
16
3.33
13.3
307
130
43.5
0.46
12
3.41
13.6
316
134
42.2
0.44
12
3.39
13.5
313
132
46.6
0.39
11
3.55
14.3
333
144
45.2
0.37
11
3.52
14.1
330
143
41.8
0.36
11
3.44
13.8
320
138
-
-
38.0
0.93
21
3.43
13.9
320
122
36.9
0.89
22
3.41
13.8
317
121
34.1
0.86
22
3.33
13.4
308
117
37.4
0.82
18
3.41
13.8
317
121
36.3
0.78
19
3.38
13.7
314
120
41.1
0.60
16
3.58
14.6
360
141
42.4
0.63
16
3.61
14.7
364
142
39.1
0.83
19
3.50
14.2
345
130
38.0
0.58
17
3.50
14.2
350
136
42.4
0.47
12
3.58
14.6
360
141
41.2
0.45
12
3.55
14.4
357
139
35.1
0.77
20
3.39
13.7
331
125
38.0
0.79
20
3.48
14.1
341
129
38.7
0.68
15
3.48
14.1
341
129
37.6
0.65
16
3.45
14.0
338
127
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
35.6 39.0
33.5
34.7
38.0
0.61 0.42
0.75
0.63
0.44
16
12
19
16
12
3.21 3.31
3.30
3.37
3.47
12.7 13.2
13.3
13.6
14.0
288
304
304
328
346
118
129
116
124
135
45.5
0.41
11
3.72
15.2
380
151
44.1
0.39
11
3.70
15.1
376
150
40.7
0.37
11
3.61
14.7
365
145
-
-
71
-
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction service valves.
1225
59
36.0
0.69
19
2.78
10.7
209
101
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
MODEL: GSX130421B* / CA*F3642*6C*
37.2
0.86
19
3.64
15.1
388
136
36.1
0.82
20
3.61
15.0
384
135
33.3
0.79
20
3.53
14.6
372
131
36.8
0.71
15
3.61
15.0
384
135
35.7
0.68
16
3.58
14.9
380
134
63
33.0
0.65
16
3.50
14.5
369
130
40.2
0.65
15
3.76
15.6
409
149
39.1
0.62
16
3.73
15.5
405
147
36.1
0.60
16
3.64
15.1
393
143
40.3
0.49
12
3.73
15.5
405
147
39.1
0.47
12
3.70
15.3
401
146
67
36.1
0.45
12
3.61
14.9
389
141
43.2
0.42
11
3.87
16.2
427
158
41.9
0.40
11
3.84
16.1
423
157
38.7
0.39
11
3.75
15.6
410
152
-
-
71
-
33.4
0.97
19
3.68
15.6
398
133
32.5
0.93
20
3.66
15.5
394
131
30.0
0.90
20
3.57
15.1
382
127
32.9
0.86
16
3.66
15.5
394
131
31.9
0.82
17
3.63
15.4
390
130
59
29.5
0.79
17
3.54
14.9
378
126
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
36.1
0.97
20
3.57
14.8
360
128
35.1
0.92
21
3.54
14.6
357
127
32.4
0.89
22
3.46
14.2
346
123
35.5
0.85
18
3.54
14.6
357
127
34.5
0.81
18
3.51
14.5
353
126
59
31.8
0.78
19
3.43
14.1
343
122
105
34.4
0.87
18
3.76
16.0
428
141
33.4
0.83
18
3.73
15.9
424
140
30.9
0.80
19
3.64
15.4
411
135
34.1
0.72
14
3.73
15.9
424
140
33.1
0.68
15
3.70
15.7
420
138
63
30.5
0.66
15
3.61
15.3
407
134
37.3
0.66
14
3.88
16.5
452
154
36.2
0.63
15
3.85
16.4
448
152
33.4
0.61
15
3.76
15.9
434
148
37.3
0.50
11
3.85
16.4
448
152
36.3
0.47
11
3.82
16.2
443
151
67
33.5
0.46
11
3.73
15.8
430
146
115
40.0
0.42
10
4.00
17.2
472
164
38.8
0.40
10
3.97
17.0
467
162
35.8
0.39
10
3.88
16.5
453
157
-
-
71
-
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130421B*/VSX130421A*
85
80
IDB*
41.6
0.93
23
2.91
11.2
223
107
37.9
0.90
26
2.84
10.9
216
104
41.1
0.93
25
2.91
11.2
223
107
42.3
0.98
24
2.93
11.3
225
108
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1575
1225
1400
1575
43.1
0.94
24
2.99
11.6
242
115
41.9
0.90
25
2.96
11.5
240
114
38.6
0.87
25
2.90
11.2
232
110
42.5
0.87
22
2.96
11.5
240
114
63
38.1
0.80
23
2.88
11.1
230
109
41.3
0.83
23
2.94
11.4
237
113
* Entering Indoor Dry Bulb Temperature
1400
1225
59
37.3
0.86
24
2.82
10.8
214
103
40.4
0.89
24
2.89
11.1
220
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
45.2
0.85
22
3.07
12.0
255
126
43.9
0.81
23
3.05
11.9
253
124
40.5
0.78
24
2.98
11.6
245
121
45.4
0.71
19
3.05
11.9
253
124
67
40.7
0.65
20
2.96
11.4
243
119
44.1
0.68
20
3.03
11.8
250
123
48.2
0.69
19
3.17
12.4
266
134
46.8
0.66
20
3.14
12.3
264
132
43.2
0.63
21
3.07
12.0
256
128
48.5
0.53
15
3.14
12.3
264
132
71
43.5
0.49
16
3.05
11.9
253
127
47.1
0.51
16
3.12
12.2
261
131
MODEL: G/VSX130421B* / CA*F3642*6C*
41.3
1.00
24
3.14
12.2
252
114
40.1
0.96
25
3.11
12.1
250
113
37.0
0.93
26
3.04
11.8
242
110
40.6
0.96
23
3.11
12.1
250
113
59
36.4
0.89
24
3.02
11.7
240
109
39.4
0.92
24
3.09
12.0
247
112
44.1
0.88
23
3.30
12.9
287
133
42.8
0.84
24
3.27
12.8
284
131
39.5
0.81
24
3.20
12.5
275
127
44.3
0.74
19
3.27
12.8
284
131
67
39.7
0.68
20
3.17
12.4
273
126
43.1
0.70
20
3.25
12.7
281
130
47.1
0.71
20
3.40
13.4
299
141
45.7
0.68
20
3.37
13.3
296
140
42.2
0.66
21
3.29
12.9
287
136
47.4
0.55
15
3.37
13.3
296
140
71
42.5
0.51
16
3.27
12.8
284
134
46.0
0.52
16
3.35
13.2
293
139
40.3
1.00
24
3.32
13.3
287
119
39.2
0.99
25
3.30
13.1
284
118
36.2
0.95
26
3.22
12.8
276
114
39.6
1.00
23
3.30
13.1
284
118
59
35.5
0.91
24
3.20
12.7
273
113
38.5
0.94
24
3.27
13.0
281
116
41.1
1.00
24
3.39
13.6
309
126
39.9
0.95
25
3.36
13.5
306
125
36.9
0.92
25
3.29
13.1
297
121
43.1
0.90
23
3.49
14.0
326
138
41.8
0.86
24
3.47
13.9
323
137
38.6
0.83
24
3.39
13.5
313
132
45.9
0.73
20
3.60
14.5
340
147
44.6
0.70
20
3.58
14.4
337
145
41.2
0.67
21
3.49
14.0
327
141
39.4
1.00
23
3.49
14.2
327
125
38.2
1.00
25
3.46
14.0
324
123
35.3
0.98
26
3.38
13.6
314
120
40.1
1.00
23
3.56
14.5
352
133
39.0
0.98
25
3.53
14.4
348
131
36.0
0.95
26
3.45
14.0
338
127
42.0
0.93
23
3.67
15.0
371
145
40.8
0.89
24
3.64
14.8
368
143
37.7
0.86
24
3.55
14.4
357
139
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
36.3 38.8 41.5 34.7
35.4
37.8
0.85 0.69 0.52 0.94
0.88
0.72
23
20
16
24
23
20
3.26 3.36 3.46 3.35
3.42
3.53
13.0 13.4 13.9 13.5
13.8
14.3
294
310
323
311
334
353
120
131
140
119
126
138
39.3 42.0 44.9 37.6
38.4
41.0
0.88 0.72 0.54 0.97
0.91
0.74
20
23
20
16
24
23
3.61
3.34 3.44 3.55 3.43
3.50
13.3 13.8 14.3 13.9
14.2
14.7
303
320
333
320
345
364
124
135
144
122
130
142
40.5 43.3 46.3 38.7
39.5
42.2
0.93 0.75 0.56 1.00
0.96
0.78
22
19
15
23
22
19
3.36 3.47 3.58 3.46
3.53
3.64
13.5 13.9 14.4 14.0
14.4
14.8
306
323
337
324
348
368
125
137
145
123
131
143
NOTE: Shaded area is AHRI Rating Conditions
42.1
0.98
24
3.20
12.5
271
122
40.9
0.93
25
3.18
12.4
269
120
37.7
0.90
25
3.11
12.1
261
117
41.5
0.90
22
3.18
12.4
269
120
63
37.2
0.83
23
3.08
12.0
258
116
40.3
0.86
23
3.15
12.3
266
119
75
44.8
0.76
20
3.78
15.5
387
154
43.5
0.72
21
3.75
15.4
383
153
40.2
0.70
21
3.66
15.0
372
148
45.1
0.58
15
3.75
15.4
383
153
71
40.5
0.54
16
3.64
14.8
368
147
43.8
0.56
16
3.72
15.2
380
151
EXPANDED PERFORMANCE DATA
38.1
1.00
22
3.70
15.4
396
139
37.0
1.00
24
3.67
15.3
392
138
34.2
0.99
25
3.58
14.9
380
134
37.6
1.00
22
3.67
15.3
392
138
63
33.6
0.91
23
3.56
14.7
376
132
36.5
0.95
23
3.64
15.1
388
136
39.9
0.97
23
3.82
15.9
418
152
38.8
0.92
23
3.79
15.8
414
150
35.8
0.89
24
3.70
15.3
401
146
40.1
0.81
19
3.79
15.8
414
150
67
36.0
0.74
20
3.67
15.2
397
144
39.0
0.77
20
3.76
15.6
410
149
42.6
0.78
20
3.94
16.5
436
162
41.3
0.75
20
3.91
16.4
431
160
38.2
0.72
21
3.81
15.9
418
155
42.9
0.60
15
3.91
16.4
431
160
71
38.4
0.56
16
3.78
15.8
414
154
41.6
0.58
16
3.88
16.2
427
158
34.6
1.00
20
3.74
15.9
406
135
33.6
1.00
22
3.71
15.8
402
134
31.0
1.00
23
3.63
15.4
390
130
34.0
1.00
20
3.71
15.8
402
134
59
30.5
0.98
22
3.60
15.2
386
129
33.0
1.00
22
3.68
15.6
398
133
AMPS=outdoor unit amps (comp.+fan)
37.4
1.00
22
3.62
15.0
368
131
36.3
1.00
24
3.60
14.9
364
129
33.5
1.00
25
3.51
14.5
353
126
36.7
1.00
21
3.60
14.9
364
129
59
32.9
0.97
24
3.48
14.4
350
124
35.7
1.00
23
3.57
14.8
360
128
105
35.3
1.00
21
3.82
16.3
437
144
34.3
1.00
23
3.79
16.2
433
142
31.6
0.99
24
3.70
15.7
420
138
34.8
1.00
20
3.79
16.2
433
142
63
31.2
0.92
22
3.67
15.6
416
137
33.8
0.96
21
3.76
16.0
428
141
37.0
0.98
21
3.94
16.9
462
157
35.9
0.93
22
3.91
16.7
457
155
33.1
0.90
22
3.82
16.2
443
151
37.2
0.82
18
3.91
16.7
457
155
67
33.3
0.75
19
3.79
16.1
439
149
36.1
0.78
18
3.88
16.5
452
154
115
39.4
0.79
18
4.07
17.5
481
167
38.3
0.75
19
4.04
17.3
477
166
35.4
0.73
19
3.94
16.8
462
161
39.7
0.61
14
4.04
17.3
477
166
71
35.6
0.56
15
3.91
16.7
458
159
38.6
0.58
15
4.01
17.2
472
164
COOLING OPERATION
COOLING PERFORMANCE DATA GSX130421B*/VSX130421A*
37
38
75
70
IDB*
59
40.4
0.71
19
3.17
11.6
215
104
43.8
0.73
18
3.24
12.0
221
108
45.1
0.77
18
3.26
12.1
223
109
41.1
0.81
22
3.19
11.7
217
105
44.5
0.84
21
3.26
12.1
223
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
45.8
0.75
20
3.33
12.4
240
116
42.3
0.72
20
3.25
12.0
233
112
45.4
0.61
16
3.30
12.3
238
114
46.7
0.64
15
3.33
12.4
240
116
63
41.9
0.59
16
3.23
11.9
231
111
49.6
0.57
16
3.42
12.8
254
126
45.8
0.55
16
3.35
12.4
246
122
49.7
0.43
12
3.40
12.7
251
125
51.2
0.45
12
3.42
12.8
254
126
67
45.9
0.41
12
3.32
12.3
244
121
53.2
0.36
11
3.53
13.2
265
134
49.1
0.35
11
3.45
12.9
257
130
-
71
-
43.5
0.87
22
3.50
13.1
251
115
40.1
0.83
22
3.42
12.7
243
111
42.7
0.76
19
3.47
12.9
248
114
44.0
0.80
18
3.50
13.0
251
115
59
39.5
0.73
19
3.39
12.6
241
110
44.8
0.77
20
3.57
13.4
270
122
41.3
0.75
20
3.49
13.0
262
118
44.3
0.64
16
3.54
13.2
267
121
45.6
0.67
16
3.57
13.4
270
122
63
40.9
0.61
16
3.46
12.9
259
117
75
48.4
0.59
16
3.68
13.8
285
133
44.7
0.56
17
3.59
13.4
276
129
48.5
0.44
12
3.65
13.7
282
132
50.0
0.46
12
3.67
13.8
285
133
67
44.8
0.42
12
3.56
13.3
274
128
52.0
0.38
11
3.79
14.3
297
142
48.0
0.36
11
3.70
13.9
288
138
-
71
-
42.4
0.89
22
3.70
14.2
285
119
39.2
0.86
22
3.62
13.8
277
116
41.7
0.78
19
3.67
14.1
282
118
43.0
0.82
18
3.70
14.2
285
119
59
38.5
0.75
19
3.59
13.7
274
115
47.3
0.60
16
3.90
15.0
324
139
43.7
0.58
17
3.80
14.6
314
134
47.4
0.45
12
3.87
14.9
321
137
48.8
0.47
12
3.90
15.0
324
139
50.8
0.39
11
4.02
15.6
338
148
46.8
0.37
11
3.92
15.1
328
143
-
45.0 48.7 52.3
0.83 0.63 0.41
19
16
11
3.81 3.93 4.05
14.7 15.1 15.7
310
327
341
128
140
149
(TVA) conditions
43.7
0.79
20
3.78
14.5
307
127
40.3
0.77
20
3.69
14.1
298
123
43.2
0.65
16
3.75
14.4
304
126
44.5
0.68
16
3.78
14.5
307
127
42.6
0.96
21
3.92
15.3
328
127
41.4
0.92
22
3.89
15.2
325
125
38.2
0.88
22
3.79
14.7
315
122
40.7
0.81
19
3.86
15.0
321
124
41.9
0.85
18
3.89
15.2
325
125
46.1
0.62
16
4.09
16.1
369
146
47.5
0.65
16
4.12
16.2
373
147
43.9
0.86
19
4.00
15.7
353
135
42.6
0.60
17
3.99
15.6
358
141
46.2
0.47
12
4.06
15.9
365
144
47.6
0.49
12
4.09
16.0
369
146
39.3
0.79
20
3.87
15.1
339
129
42.6
0.82
20
3.97
15.5
349
133
42.2
0.67
16
3.94
15.4
346
132
43.5
0.71
16
3.97
15.5
349
133
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
39.9 43.7
37.6
38.9
42.7
0.63 0.44
0.78
0.65
0.45
16
13
19
17
13
3.66 3.77
3.77
3.84
3.96
14.0 14.5
14.6
15.0
15.5
295
311
312
336
354
122
133
120
128
140
51.0
0.42
11
4.26
16.8
389
157
49.5
0.40
11
4.22
16.7
385
155
45.7
0.38
12
4.12
16.2
373
150
-
71
-
EXPANDED PERFORMANCE DATA
MBh
45.8 47.2 51.1 54.8 44.8 46.1 49.9 53.6 43.7
S/T
0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.93
Delta T 21
19
15
11
21
19
16
11
21
1800
KW
3.29 3.35 3.45 3.55 3.52 3.59 3.70 3.82 3.73
AMPS 12.2 12.5 12.9 13.4 13.2 13.5 13.9 14.5 14.3
HI PR 226
243
256
267
253
272
288
300
288
LO PR 110
117
127
136
116
123
135
143
120
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction service valves.
1600
1400
1800
1600
1400
Airflow
65
MODEL: GSX130481B* / CA*F4860*6B*
40.5
0.85
20
4.13
16.5
393
140
37.4
0.82
20
4.03
16.1
381
136
40.1
0.70
16
4.09
16.4
389
138
41.3
0.73
15
4.13
16.5
393
140
63
37.0
0.67
16
4.00
15.9
377
134
43.8
0.64
16
4.26
17.1
415
153
40.5
0.62
16
4.15
16.6
403
148
43.9
0.48
12
4.22
16.9
411
151
45.2
0.51
12
4.26
17.1
415
152
67
40.5
0.47
12
4.12
16.5
399
146
47.0
0.41
11
4.39
17.7
433
162
43.4
0.40
11
4.29
17.2
420
158
-
71
-
36.4
0.96
20
4.18
17.1
404
136
33.6
0.92
20
4.08
16.6
391
132
35.8
0.84
17
4.14
16.9
400
134
36.9
0.88
17
4.18
17.1
404
136
59
33.1
0.81
18
4.04
16.5
388
130
37.5
0.86
18
4.26
17.5
434
145
34.6
0.83
19
4.16
17.0
421
140
37.1
0.70
15
4.23
17.4
430
143
38.2
0.74
14
4.26
17.5
434
144
63
34.3
0.68
15
4.13
16.9
417
139
41.8
0.68
15
4.44
18.3
463
159
40.6
0.65
15
4.40
18.1
459
158
37.5
0.63
15
4.29
17.6
445
153
40.7
0.49
11
4.36
17.9
454
156
41.9
0.51
11
4.40
18.1
459
158
67
37.5
0.47
12
4.26
17.4
440
151
115
40.5 41.7 45.1 48.5 37.5 38.6
1.00 0.89 0.67 0.43 1.00 0.90
21
19
16
11
19
18
4.07 4.16 4.29 4.43 4.21 4.30
16.3 16.7 17.2 17.9 17.3 17.7
369
397
419
437
408
439
133
141
154
164
137
146
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
39.3
0.95
21
4.04
16.1
365
131
36.3
0.92
22
3.95
15.7
354
127
38.7
0.84
19
4.01
16.0
362
130
39.8
0.88
18
4.04
16.1
365
131
59
35.7
0.81
19
3.91
15.5
351
126
105
44.9
0.44
10
4.58
19.0
483
170
43.6
0.42
10
4.54
18.8
478
168
40.2
0.40
11
4.43
18.3
464
163
-
71
-
CO OLING O PERATION
COOLING PERFORMANCE DATA GSX130481B*/VSX130481A*
85
80
IDB*
59
41.8
0.88
24
3.21
11.9
219
106
45.3
0.92
24
3.29
12.2
226
110
46.7
0.96
23
3.31
12.3
228
111
42.5
0.93
26
3.24
12.0
221
108
46.1
0.96
25
3.31
12.3
228
111
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
43.4
0.89
25
3.30
12.2
238
114
47.0
0.93
25
3.38
12.6
245
118
63
42.7
0.83
23
3.28
12.1
236
113
46.3
0.86
23
3.35
12.5
243
117
47.7
0.90
22
3.38
12.6
245
118
45.4
0.81
24
3.40
12.6
251
125
49.2
0.84
24
3.48
13.0
259
129
67
45.6
0.67
20
3.37
12.5
249
124
49.5
0.70
20
3.45
12.9
256
127
50.9
0.73
19
3.48
13.0
259
129
48.5
0.65
21
3.50
13.1
262
133
52.5
0.68
20
3.58
13.5
270
137
71
48.8
0.50
16
3.47
13.0
259
132
52.9
0.52
16
3.56
13.4
267
136
54.4
0.55
15
3.58
13.5
270
137
41.5
0.96
26
3.47
12.9
248
114
45.0
1.00
26
3.55
13.3
256
117
59
40.8
0.92
25
3.44
12.8
246
112
44.2
0.95
24
3.52
13.2
253
116
45.6
1.00
23
3.55
13.3
256
117
42.4
0.93
26
3.54
13.2
267
121
45.9
0.96
25
3.62
13.6
275
125
63
41.7
0.86
24
3.51
13.1
264
120
45.2
0.89
23
3.59
13.5
272
123
46.6
0.93
22
3.62
13.6
275
125
75
44.4
0.84
24
3.65
13.7
282
132
48.1
0.87
24
3.73
14.1
291
136
67
44.6
0.70
20
3.62
13.6
279
131
48.3
0.72
20
3.70
13.9
288
135
49.7
0.76
19
3.73
14.1
291
136
47.3
0.68
21
3.76
14.2
294
140
51.3
0.70
21
3.85
14.6
303
145
71
47.7
0.52
16
3.73
14.1
291
139
51.6
0.54
16
3.82
14.5
300
143
53.2
0.57
15
3.85
14.6
303
145
40.6
0.98
26
3.67
14.0
282
118
43.9
1.00
25
3.76
14.4
291
122
59
39.9
0.94
25
3.65
13.9
279
117
43.2
0.97
24
3.73
14.3
288
120
44.5
1.00
23
3.76
14.4
291
122
43.3
0.86
24
3.86
14.9
321
137
46.9
0.89
24
3.96
15.3
331
141
46.2
0.70
21
3.99
15.4
334
146
50.1
0.72
21
4.08
15.9
345
151
46.1 48.3 51.6
1.00 0.93 0.76
24
23
20
3.87 3.99 4.11
14.9 15.4 16.0
316
334
348
131
143
152
Rating Conditions
41.3
0.95
26
3.75
14.4
304
126
44.8
0.98
25
3.84
14.8
313
129
44.2
1.00
23
3.98
15.6
335
129
39.6
1.00
26
3.85
15.0
321
124
42.9
1.00
25
3.95
15.4
331
128
45.0
1.00
23
4.06
16.0
360
137
40.3
0.98
26
3.94
15.4
346
132
43.7
1.00
25
4.03
15.8
356
136
47.1
0.96
23
4.19
16.5
380
150
42.2
0.88
25
4.06
15.9
365
144
45.8
0.92
24
4.16
16.4
376
148
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
40.7 43.5 46.5 38.9
39.7
42.5
0.88 0.72 0.54 0.97
0.91
0.74
24
20
16
25
24
21
3.72 3.83 3.95 3.82
3.90
4.03
14.3 14.7 15.3 14.9
15.2
15.8
301
317
331
318
342
362
124
136
145
123
131
143
44.1 47.2 50.4 42.1
43.1
46.0
0.91 0.74 0.56 1.00
0.94
0.77
20
23
20
16
24
23
4.12
3.81 3.93 4.05 3.92
4.00
14.7 15.2 15.7 15.3
15.7
16.2
310
327
341
328
353
373
128
140
149
127
135
147
44.3
47.4
45.5 48.6 51.9 43.4
0.96 0.78 0.58 1.00
1.00
0.80
22
19
15
22
23
19
3.84 3.96 4.08 3.95
4.03
4.16
14.8 15.3 15.9 15.4
15.8
16.4
313
331
345
331
356
376
129
141
151
128
136
148
50.3
0.78
20
4.32
17.1
397
160
45.1
0.72
21
4.19
16.5
381
153
48.8
0.74
21
4.29
17.0
393
158
71
45.4
0.55
16
4.15
16.3
377
152
49.2
0.57
16
4.26
16.8
389
157
50.6
0.60
16
4.29
17.0
393
158
EXPANDED PERFORMANCE DATA
MBh
47.5 48.4 50.7 54.1 46.4 47.3 49.5 52.8 45.3
S/T
1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00
Delta T 24
24
23
20
24
24
23
20
23
1800
KW
3.34 3.40 3.50 3.61 3.58 3.65 3.76 3.88 3.79
AMPS 12.4 12.7 13.1 13.6 13.4 13.7 14.2 14.7 14.6
HI PR 230
248
262
273
258
278
294
306
294
LO PR 112
119
130
138
118
126
137
146
123
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI
High and low pressures are measured at the liquid and suction service valves.
1600
1400
1800
1600
1400
Airflow
65
MODEL: GSX130481B* / CA*F4860*6B*
38.3
1.00
25
4.09
16.4
389
138
41.5
1.00
24
4.19
16.8
401
143
63
37.8
0.94
23
4.06
16.2
385
137
40.9
0.98
23
4.16
16.7
397
141
42.1
1.00
22
4.19
16.8
401
143
40.1
0.92
24
4.22
16.9
411
151
43.5
0.95
24
4.33
17.4
423
156
67
40.3
0.77
20
4.19
16.8
407
149
43.7
0.80
20
4.29
17.3
419
154
45.0
0.83
19
4.33
17.4
423
156
42.8
0.74
21
4.36
17.6
428
161
46.4
0.77
21
4.47
18.1
442
166
71
43.1
0.57
16
4.32
17.4
424
159
46.7
0.60
16
4.43
17.9
437
164
48.1
0.62
15
4.47
18.1
442
166
34.8
1.00
23
4.14
16.9
399
134
37.7
1.00
22
4.24
17.4
412
139
59
34.2
1.01
23
4.11
16.8
395
133
37.1
1.00
21
4.21
17.3
408
137
38.2
1.00
20
4.24
17.4
412
139
35.5
1.00
23
4.23
17.4
430
143
38.5
1.00
22
4.33
17.9
443
147
63
35.0
0.95
22
4.20
17.2
426
142
37.9
0.99
21
4.30
17.7
439
146
39.0
1.00
20
4.33
17.9
443
147
41.5
1.00
21
4.51
18.6
473
163
37.2
0.93
23
4.36
17.9
454
156
40.3
0.96
22
4.47
18.5
468
161
67
37.4
0.77
19
4.33
17.8
449
155
40.5
0.80
19
4.44
18.3
463
159
41.7
0.84
18
4.47
18.5
468
161
115
42.0 42.8 44.8 47.8 38.9 39.6
1.00 1.00 1.00 0.81 1.00 1.00
21
22
23
20
20
20
4.14 4.23 4.36 4.50 4.28 4.37
16.6 17.0 17.6 18.2 17.6 18.0
376
405
428
446
416
448
135
144
157
167
140
149
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
37.6
1.00
25
4.01
16.0
361
130
40.7
1.00
23
4.11
16.4
373
134
59
36.9
1.01
24
3.98
15.8
358
129
40.0
1.00
23
4.07
16.3
369
133
41.2
1.00
21
4.11
16.4
373
134
105
44.3
0.82
18
4.65
19.3
493
173
39.7
0.75
20
4.50
18.6
473
166
43.0
0.78
19
4.62
19.2
488
171
71
39.9
0.58
15
4.47
18.5
469
165
43.3
0.60
15
4.58
19.0
483
170
44.6
0.63
14
4.62
19.2
488
171
COOLING O PERATION
COOLING PERFORMANCE DATA GSX130481B*/VSX130481A*
39
40
75
70
IDB*
59
50.1
0.67
21
3.87
14.4
229
101
54.2
0.69
20
3.96
14.8
236
105
55.9
0.73
19
3.99
15.0
238
106
50.9
0.76
24
3.90
14.6
231
103
55.1
0.79
23
3.99
15.0
238
106
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
56.8
0.71
21
4.07
15.3
256
112
52.4
0.68
22
3.98
14.9
249
109
63
51.9
0.56
18
3.95
14.8
246
108
56.2
0.58
17
4.04
15.2
254
111
57.9
0.61
16
4.07
15.3
256
112
61.5
0.53
17
4.20
15.8
271
123
56.7
0.51
18
4.10
15.4
263
119
67
56.8
0.39
13
4.07
15.3
260
118
61.6
0.40
13
4.17
15.7
268
122
63.4
0.42
12
4.20
15.8
271
123
66.0
0.34
12
4.33
16.4
282
131
60.9
0.33
12
4.23
16.0
274
127
71
-
53.9
0.82
23
4.29
16.2
267
112
49.7
0.79
24
4.19
15.8
259
108
59
48.9
0.69
21
4.16
15.6
257
107
53.0
0.72
20
4.26
16.1
265
111
54.6
0.75
19
4.29
16.2
267
112
55.5
0.73
21
4.38
16.6
288
119
51.2
0.70
22
4.28
16.1
279
115
63
50.7
0.58
18
4.24
16.0
276
114
54.9
0.60
17
4.35
16.4
285
118
56.5
0.63
16
4.38
16.6
288
119
75
60.0
0.55
17
4.52
17.2
304
130
55.4
0.53
18
4.41
16.7
295
126
67
55.5
0.40
14
4.38
16.5
292
125
60.1
0.42
13
4.48
17.0
301
128
62.0
0.44
12
4.52
17.2
304
130
64.4
0.36
12
4.66
17.8
317
138
59.5
0.34
13
4.55
17.3
307
134
71
-
52.6
0.84
23
4.56
17.6
304
116
48.5
0.81
24
4.45
17.1
295
113
59
47.7
0.71
21
4.41
17.0
292
111
51.7
0.74
20
4.52
17.5
301
115
53.3
0.77
19
4.56
17.6
304
116
58.6
0.57
17
4.80
18.7
346
135
54.1
0.55
18
4.68
18.1
335
131
62.9
0.36
12
4.96
19.4
360
144
58.1
0.35
13
4.84
18.8
350
139
55.8 60.4 64.8
0.79 0.59 0.38
20
16
11
4.69 4.84 5.00
18.2 18.8 19.6
331
349
364
125
136
145
(TVA) conditions
54.1
0.75
21
4.65
18.1
327
123
50.0
0.72
22
4.54
17.6
317
120
52.8
0.91
22
4.83
19.0
350
123
51.3
0.86
23
4.79
18.9
346
122
47.3
0.83
24
4.67
18.3
336
118
57.2
0.59
18
5.05
20.0
394
142
52.8
0.77
21
4.89
19.3
373
130
54.4
0.81
20
4.93
19.5
376
131
58.9
0.61
17
5.09
20.2
398
143
52.8
0.56
18
4.93
19.4
382
137
48.8
0.75
22
4.77
18.8
362
126
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
49.5 54.2
46.6
48.3
52.9
0.59 0.41
0.73
0.61
0.42
18
14
21
18
14
4.50 4.65
4.63
4.73
4.89
17.4 18.0
18.2
18.6
19.2
314
332
333
358
378
119
129
117
125
136
53.6 58.7
50.4
52.3
57.3
0.62 0.43
0.76
0.64
0.44
17
13
20
17
13
4.62 4.76
4.75
4.85
5.01
17.9 18.5
18.7
19.1
19.8
324
342
343
369
390
122
133
121
128
140
55.2 60.5
52.0
53.9
59.0
0.65 0.45
0.80
0.67
0.46
16
12
19
16
13
4.65 4.80
4.79
4.89
5.05
18.1 18.7
18.9
19.3
20.0
327
346
346
373
394
123
135
122
130
142
63.2
0.39
11
5.26
20.9
415
152
61.4
0.38
12
5.22
20.8
411
151
56.6
0.36
13
5.09
20.2
398
146
71
-
EXPANDED PERFORMANCE DATA
MBh
56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2
S/T
0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88
Delta T 22
20
16
11
22
20
16
11
22
2000
KW
4.02 4.11 4.23 4.37 4.33 4.42 4.56 4.70 4.59
AMPS 15.1 15.5 16.0 16.6 16.4 16.8 17.3 18.0 17.8
HI PR 241
259
274
285
270
291
307
320
307
LO PR 107
114
124
132
113
120
131
139
117
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA
High and low pressures are measured at the liquid and suction service valves.
1750
1500
2000
1750
1500
Airflow
65
MODEL: GSX130601B* / CA*F4961*6A*
50.2
0.80
21
5.10
20.6
419
136
46.3
0.77
22
4.97
20.0
407
132
63
45.8
0.64
18
4.93
19.8
403
130
49.7
0.66
17
5.05
20.4
415
135
51.2
0.69
16
5.10
20.6
419
136
54.3
0.61
17
5.26
21.3
443
148
50.1
0.59
18
5.13
20.7
430
144
67
50.2
0.44
14
5.09
20.5
425
142
54.4
0.46
13
5.22
21.1
438
147
56.1
0.48
12
5.26
21.3
443
148
58.3
0.39
12
5.44
22.1
462
158
53.8
0.38
12
5.30
21.5
448
153
71
-
45.1
0.91
21
5.16
21.3
431
132
41.7
0.87
22
5.03
20.7
418
128
59
41.0
0.77
19
4.99
20.5
413
127
44.4
0.80
19
5.12
21.1
426
131
45.7
0.83
18
5.16
21.3
430
132
46.5
0.81
20
5.27
21.8
463
141
42.9
0.78
21
5.14
21.2
449
136
63
42.5
0.64
17
5.10
21.0
445
135
46.0
0.66
16
5.23
21.6
459
139
47.4
0.70
15
5.27
21.8
463
141
51.8
0.64
15
5.49
22.8
494
155
50.3
0.61
16
5.44
22.6
489
153
46.4
0.59
17
5.31
21.9
475
149
67
46.5
0.44
13
5.26
21.7
470
147
50.4
0.46
12
5.40
22.4
484
152
51.9
0.48
12
5.44
22.6
489
153
115
50.2 51.7 55.9 60.0 46.5 47.9
0.94 0.84 0.64 0.41 0.95 0.85
22
20
16
11
20
19
5.03 5.14 5.31 5.48 5.20 5.32
20.3 20.8 21.5 22.3 21.5 22.0
394
424
447
466
435
468
129
137
150
160
133
142
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
48.7
0.90
23
4.99
20.1
390
128
45.0
0.87
24
4.86
19.5
378
124
59
44.2
0.76
21
4.82
19.3
374
123
47.9
0.79
20
4.95
19.9
386
126
49.4
0.83
19
4.99
20.1
390
128
105
55.6
0.41
11
5.67
23.7
515
165
54.0
0.39
11
5.63
23.5
510
163
49.8
0.38
12
5.48
22.8
495
159
71
-
CO OLING O PERATION
COOLING PERFORMANCE DATA GSX130601B*/VSX130601B*
85
80
IDB*
56.1
0.86
25
4.02
15.1
241
107
57.8
0.91
24
4.05
15.2
243
108
52.7
0.87
28
3.96
14.8
236
105
57.1
0.91
27
4.05
15.2
243
108
58.8
0.95
26
4.09
15.4
246
109
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
1750
2000
63
60.0
0.92
25
4.17
15.8
264
116
58.2
0.87
27
4.14
15.6
262
115
53.7
0.84
28
4.04
15.2
254
111
57.4
0.81
24
4.11
15.5
259
114
59.1
0.85
23
4.14
15.6
262
115
52.9
0.78
25
4.01
15.1
251
110
67
62.8
0.83
24
4.30
16.3
279
126
61.0
0.79
25
4.27
16.1
276
125
56.3
0.76
26
4.17
15.7
268
121
61.3
0.66
21
4.23
16.0
274
124
63.1
0.69
20
4.27
16.1
276
125
56.6
0.64
22
4.13
15.6
265
120
71
67.0
0.67
21
4.44
16.9
291
135
65.0
0.64
22
4.40
16.7
288
133
60.0
0.62
23
4.30
16.3
280
129
65.5
0.49
17
4.37
16.6
285
132
67.5
0.52
16
4.40
16.7
288
133
60.5
0.48
18
4.26
16.1
277
128
59
57.5
0.99
26
4.39
16.7
276
115
55.8
0.94
28
4.36
16.5
273
114
51.5
0.91
29
4.26
16.0
265
110
54.8
0.90
26
4.33
16.4
270
113
56.5
0.94
24
4.36
16.5
273
114
50.6
0.86
27
4.22
15.9
262
109
63
58.6
0.95
26
4.49
17.1
297
122
56.9
0.91
27
4.45
16.9
294
121
52.5
0.87
28
4.35
16.4
285
118
56.0
0.84
25
4.42
16.8
291
120
57.7
0.88
23
4.45
16.9
294
121
51.7
0.81
26
4.31
16.3
282
116
75
67
61.3
0.86
24
4.63
17.6
313
134
59.6
0.82
26
4.59
17.5
310
132
55.0
0.79
27
4.48
17.0
301
128
59.9
0.68
22
4.56
17.3
307
131
61.6
0.72
20
4.59
17.5
310
132
55.2
0.66
22
4.45
16.8
298
127
71
65.4
0.70
21
4.78
18.3
327
142
63.5
0.66
22
4.74
18.1
323
141
58.6
0.64
23
4.62
17.6
314
137
64.0
0.51
17
4.70
18.0
320
140
65.9
0.54
16
4.74
18.1
323
141
59.1
0.49
18
4.59
17.5
311
135
59
56.1
1.00
26
4.67
18.1
313
120
54.5
0.96
28
4.63
18.0
310
118
50.3
0.93
29
4.52
17.5
301
115
53.5
0.92
26
4.59
17.8
307
117
55.1
0.96
24
4.63
18.0
310
118
49.4
0.89
27
4.48
17.3
298
114
57.2
0.97
26
4.77
18.6
337
127
55.5
0.93
27
4.73
18.4
334
126
51.2
0.90
28
4.61
17.9
324
122
54.7
0.86
25
4.69
18.2
331
125
56.3
0.90
23
4.73
18.4
334
126
50.5
0.83
26
4.58
17.7
321
121
59.9
0.88
24
4.92
19.2
356
139
58.1
0.84
26
4.88
19.0
353
137
53.7
0.81
27
4.76
18.5
342
133
58.4
0.70
22
4.84
18.8
349
136
60.2
0.74
20
4.88
19.0
353
137
53.9
0.68
22
4.72
18.3
339
132
63.9
0.71
21
5.08
19.9
371
148
62.0
0.68
22
5.04
19.8
368
146
57.2
0.66
23
4.92
19.2
357
142
62.5
0.52
17
5.00
19.6
364
145
64.3
0.55
16
5.04
19.8
368
146
57.6
0.51
18
4.88
19.0
353
141
54.7
1.00
25
4.91
19.4
357
126
53.1
0.99
28
4.87
19.2
353
124
49.0
0.96
29
4.75
18.7
343
121
52.2
0.95
26
4.83
19.0
350
123
53.8
1.00
25
4.87
19.2
353
124
48.2
0.91
27
4.71
18.5
339
119
55.8
1.00
26
5.01
19.9
384
134
54.2
0.96
27
4.97
19.7
380
132
50.0
0.93
28
4.85
19.1
369
128
53.4
0.89
25
4.93
19.5
377
131
55.0
0.93
24
4.97
19.7
380
132
49.2
0.86
26
4.81
19.0
365
127
58.4
0.91
24
5.18
20.6
406
146
56.7
0.87
26
5.13
20.4
402
144
52.3
0.83
27
5.01
19.8
390
140
57.0
0.72
22
5.09
20.2
398
143
58.7
0.76
20
5.13
20.4
402
144
52.6
0.70
23
4.97
19.6
386
139
Outdoor Ambient Temperature
85
95
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
67
62.3
0.74
21
5.35
21.3
423
155
60.5
0.70
22
5.30
21.1
419
154
55.8
0.68
23
5.17
20.5
406
149
60.9
0.54
17
5.26
20.9
415
152
62.8
0.57
16
5.30
21.1
419
154
56.2
0.52
18
5.13
20.4
402
148
71
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is AHRI Rating Conditions
High and low pressures are measured at the liquid and suction service valves.
1500
2000
1750
1500
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
59
51.8
0.83
26
3.93
14.7
234
104
MBh
S/T
Delta T
KW
AMPS
HI PR
LO PR
Airflow
65
MODEL: GSX130601B* / CA*F4961*6A*
59
63
53.0
1.00
24
5.22
21.2
432
140
51.4
1.00
27
5.18
21.0
428
139
47.5
0.96
28
5.05
20.4
415
134
50.7
0.92
25
5.14
20.8
424
137
52.2
0.97
23
5.18
21.0
428
139
46.8
0.89
26
5.01
20.2
411
133
67
55.5
0.94
24
5.39
21.9
456
153
53.9
0.90
25
5.35
21.7
452
151
49.7
0.87
26
5.22
21.1
438
147
54.2
0.75
21
5.31
21.5
447
150
55.8
0.79
20
5.35
21.7
452
151
50.0
0.72
22
5.17
20.9
434
145
71
59.2
0.76
21
5.57
22.7
476
163
57.5
0.73
22
5.53
22.5
471
161
53.1
0.70
23
5.39
21.9
457
156
57.9
0.56
17
5.48
22.3
467
160
59.6
0.59
16
5.53
22.5
471
161
53.4
0.54
18
5.34
21.7
453
155
59
48.2
1.00
22
5.29
21.9
444
136
46.7
1.00
25
5.24
21.7
439
135
43.1
1.00
26
5.11
21.1
426
131
45.9
0.99
24
5.20
21.5
435
133
47.3
1.00
22
5.24
21.7
439
135
42.4
0.96
25
5.07
20.9
422
129
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
52.0
1.00
24
5.11
20.7
402
132
50.5
1.00
27
5.07
20.5
398
130
46.6
1.00
28
4.94
19.9
386
126
49.6
0.98
26
5.03
20.3
394
129
51.1
1.00
23
5.07
20.5
398
130
45.8
0.95
27
4.90
19.7
382
125
105
63
49.1
1.00
23
5.40
22.5
477
145
47.7
1.00
25
5.36
22.3
473
143
44.0
0.97
26
5.23
21.6
459
139
46.9
0.93
23
5.32
22.0
468
142
48.4
1.00
22
5.36
22.3
473
143
43.3
0.90
24
5.18
21.4
454
138
67
51.4
0.95
22
5.58
23.2
504
158
49.9
0.91
24
5.54
23.0
499
157
46.1
0.87
25
5.40
22.4
484
152
50.2
0.76
20
5.49
22.8
494
155
51.7
0.79
19
5.54
23.0
499
157
46.3
0.73
21
5.35
22.2
479
150
115
54.8
0.77
19
5.77
24.1
526
168
53.2
0.74
21
5.72
23.9
521
167
49.1
0.71
21
5.58
23.2
505
162
53.6
0.57
16
5.67
23.7
515
165
55.2
0.59
15
5.72
23.9
521
167
49.5
0.55
17
5.53
23.0
500
160
71
COOLING O PERATION
COOLING PERFORMANCE DATA GSX130601B*/VSX130601B*
41
42
75
70
IDB*
234
107
31.6
0.79
22
HI PR
LO PR
MBh
S/T
Delta T
63
22
S/T
Delta T
21
S/T
Delta T
6.4
236
108
A MPS
HI PR
LO PR
2.52
0.77
0.86
MBh
KW
36.3
107
35.3
LO PR
6.5
115
254
6.5
2.57
19
114
252
6.3
234
HI PR
2.55
20
111
A MPS
2.50
0.73
0.82
MBh
KW
35.3
104
34.2
LO PR
6.3
244
6.2
227
HI PR
2.49
20
0.71
32.5
114
252
6.5
2.55
15
0.63
36.0
113
249
6.4
2.53
16
0.60
34.9
109
242
6.3
2.47
16
0.58
32.2
A MPS
2.44
6.3
KW
2.50
18
Delta T
KW
0.76
S/T
A MPS
106
34.7
231
HI PR
MBh
6.3
LO PR
2.48
19
Delta T
KW
0.72
S/T
A MPS
103
33.7
224
HI PR
MBh
6.1
LO PR
2.42
KW
19
Delta T
A MPS
0.70
S/T
59
31.1
MBh
67
280
134
126
7.0
2.72
11
0.37
42.2
133
277
6.9
2.70
11
0.36
41.0
129
269
6.7
2.64
11
0.34
37.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
268
6.7
2.64
16
0.58
39.3
124
266
6.7
2.62
16
0.56
38.2
121
258
6.5
2.56
17
0.54
35.2
124
266
6.7
2.62
12
0.44
39.4
123
263
6.6
2.60
12
0.42
38.2
120
255
6.5
2.54
12
0.40
35.3
59
114
265
6.9
2.70
21
0.89
34.5
113
262
6.8
2.68
22
0.85
33.5
110
254
6.6
2.62
22
0.82
30.9
113
262
6.8
2.68
18
0.78
33.9
112
260
6.8
2.66
19
0.75
32.9
109
252
6.6
2.60
19
0.72
30.4
63
67
133
301
7.3
2.84
16
0.60
38.4
131
298
7.2
2.82
16
0.58
37.3
128
289
7.0
2.75
17
0.55
34.4
131
298
7.2
2.81
12
0.45
38.5
130
295
7.1
2.79
12
0.43
37.4
126
286
7.0
2.73
13
0.42
34.5
141
314
7.5
2.92
11
0.39
41.2
140
311
7.5
2.90
11
0.37
40.0
136
302
7.3
2.83
12
0.36
36.9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
119
301
7.5
2.86
21
0.91
33.6
118
298
7.4
2.84
22
0.87
32.7
114
289
7.2
2.77
22
0.84
30.1
118
298
7.4
2.84
18
0.80
33.1
116
295
7.3
2.81
19
0.77
32.1
113
286
7.1
2.75
19
0.74
29.6
126
324
7.6
2.92
19
0.82
34.6
125
321
7.6
2.90
20
0.78
33.6
121
311
7.4
2.83
20
0.75
31.0
125
321
7.6
2.90
16
0.67
34.3
124
318
7.5
2.87
16
0.64
33.3
120
308
7.3
2.81
17
0.62
30.7
63
138
342
7.9
3.01
16
0.62
37.5
137
339
7.8
2.98
16
0.59
36.4
133
329
7.6
2.91
17
0.57
33.6
137
339
7.8
2.98
12
0.47
37.6
135
336
7.7
2.96
12
0.44
36.5
131
326
7.5
2.89
13
0.43
33.7
67
147
357
8.2
3.10
11
0.40
40.2
146
354
8.1
3.08
11
0.38
39.1
141
343
7.9
3.01
12
0.37
36.1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
125
343
8.0
3.00
21
0.94
32.8
124
340
7.9
2.98
22
0.90
31.9
120
330
7.7
2.91
22
0.87
29.4
124
340
7.9
2.98
18
0.83
32.3
122
336
7.8
2.95
19
0.79
31.3
119
326
7.6
2.88
19
0.76
28.9
59
133
369
8.1
3.06
19
0.84
33.8
131
366
8.1
3.04
20
0.80
32.8
128
355
7.9
2.97
21
0.78
30.3
131
366
8.1
3.04
16
0.69
33.4
130
362
8.0
3.02
16
0.66
32.5
126
351
7.8
2.94
17
0.64
30.0
63
67
145
390
8.4
3.16
16
0.64
36.6
144
386
8.3
3.13
17
0.61
35.5
139
375
8.1
3.06
17
0.59
32.8
144
386
8.3
3.13
12
0.48
36.6
142
382
8.3
3.11
12
0.46
35.6
138
371
8.0
3.04
13
0.44
32.8
Ente r ing Indoor We t Bulb Te m pe rature
95
Outdoor Am bie nt Te m pe rature
85
NOTE: Shaded area is A CCA (TV A ) conditions
122
285
7.0
2.75
19
0.80
35.5
120
282
7.0
2.73
20
0.76
34.4
117
274
6.8
2.67
20
0.73
31.8
120
282
7.0
2.73
16
0.65
35.1
119
279
6.9
2.71
16
0.62
34.1
116
271
6.7
2.65
17
0.60
31.5
75
EXPANDED PERFORM ANCE DATA
High and low pressures are measured at the liquid and suction service valves.
* Entering Indoor Dry Bulb Temperature
1350
1200
1050
1350
1200
1050
Airflow
65
MODEL: GSX130363 A* / CA*F3636*6C*
154
407
8.7
3.26
11
0.41
39.3
153
403
8.6
3.23
11
0.39
38.1
148
391
8.4
3.16
12
0.38
35.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
63
139
415
8.7
3.19
19
0.88
32.1
138
411
8.6
3.16
20
0.83
31.2
134
399
8.3
3.09
20
0.81
28.8
138
411
8.6
3.16
16
0.72
31.8
136
407
8.5
3.14
16
0.69
30.8
132
395
8.3
3.06
16
0.66
28.5
67
152
439
8.9
3.29
16
0.66
34.7
150
434
8.9
3.26
16
0.63
33.7
146
421
8.6
3.18
17
0.61
31.1
150
434
8.9
3.26
12
0.50
34.8
149
430
8.8
3.24
12
0.48
33.8
144
417
8.5
3.16
13
0.46
31.2
162
458
9.3
3.39
11
0.43
37.3
160
453
9.2
3.37
11
0.41
36.2
155
439
8.9
3.29
11
0.39
33.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
135
427
8.9
3.23
19
0.99
28.9
134
422
8.9
3.20
20
0.94
28.0
130
410
8.6
3.12
21
0.91
25.9
134
422
8.9
3.20
17
0.87
28.4
133
418
8.8
3.17
17
0.83
27.6
129
406
8.5
3.10
18
0.80
25.4
63
144
459
9.2
3.29
18
0.88
29.7
143
454
9.1
3.27
19
0.84
28.9
138
441
8.8
3.19
19
0.81
26.6
143
454
9.1
3.27
15
0.73
29.4
141
450
9.0
3.24
15
0.69
28.6
137
436
8.7
3.16
15
0.67
26.4
AMPS=outdoor unit amps (comp.+fan)
KW =Total system power
131
386
8.5
3.12
21
0.98
31.2
130
382
8.4
3.10
22
0.93
30.3
126
371
8.2
3.02
22
0.90
27.9
130
382
8.4
3.10
18
0.86
30.7
128
378
8.3
3.07
19
0.82
29.8
124
367
8.1
3.00
19
0.79
27.5
105
115
157
485
9.5
3.40
15
0.67
32.2
156
480
9.4
3.37
15
0.64
31.2
151
466
9.1
3.29
16
0.61
28.8
156
480
9.4
3.37
11
0.50
32.2
154
475
9.3
3.34
11
0.48
31.3
149
461
9.0
3.26
12
0.46
28.9
67
167
506
9.8
3.51
10
0.43
34.5
166
501
9.7
3.48
11
0.41
33.5
161
486
9.5
3.40
11
0.40
31.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130363A*
85
80
IDB*
35.6
0.84
105
34.9
0.90
24
LO PR
MBh
S/T
Delta T
6.4
0.94
23
S/T
Delta T
32.7
0.91
26
LO PR
MBh
S/T
Delta T
0.91
0.94
26
MBh
S/T
Delta T
25
Delta T
6.5
241
110
AMPS
HI PR
LO PR
2.55
0.99
S/T
KW
36.5
MBh
117
259
6.7
2.61
24
0.95
37.2
116
257
238
109
HI PR
2.59
6.6
25
113
2.54
6.4
LO PR
KW
AMPS
36.2
106
35.5
LO PR
6.4
249
6.3
231
HI PR
2.53
26
0.88
33.4
116
257
6.6
2.59
22
115
AMPS
2.48
109
HI PR
KW
6.4
238
AMPS
2.54
0.88
35.9
MBh
KW
36.7
108
LO PR
254
236
HI PR
2.57
6.5
2.52
6.4
KW
AMPS
23
112
246
6.2
229
HI PR
2.51
AMPS
2.46
KW
24
23
0.81
0.87
S/T
Delta T
63
32.9
59
32.2
MBh
67
128
274
6.9
2.68
23
0.86
39.0
127
271
2.66
6.8
24
0.82
37.9
123
263
6.6
2.60
24
0.79
34.9
127
271
6.8
2.66
19
0.72
39.2
126
268
2.64
6.7
20
0.69
38.1
122
260
6.6
2.58
20
0.66
35.1
71
137
285
7.1
2.76
20
0.70
41.6
135
283
2.74
7.0
21
0.67
40.4
131
274
6.9
2.68
21
0.64
37.3
135
283
7.0
2.74
15
0.54
41.9
134
280
2.72
7.0
16
0.51
40.7
130
271
6.8
2.66
16
0.49
37.5
59
117
270
7.0
2.74
24
1.00
35.7
116
268
2.72
6.9
26
0.98
34.6
112
260
6.8
2.66
26
0.94
32.0
116
268
6.9
2.72
24
1.00
35.1
114
265
2.70
6.9
24
0.93
34.0
111
257
6.7
2.64
25
0.90
31.4
63
67
135
307
7.4
2.88
23
0.89
38.1
134
304
2.86
7.3
24
0.85
37.0
130
295
7.1
2.79
25
0.82
34.1
134
304
7.3
2.86
19
0.75
38.3
133
301
2.84
7.3
20
0.71
37.2
129
292
7.1
2.77
21
0.69
34.3
71
144
320
7.7
2.97
20
0.72
40.6
143
317
2.95
7.6
21
0.69
39.5
139
308
7.4
2.88
21
0.67
36.4
143
317
7.6
2.95
16
0.56
40.9
141
314
2.93
7.5
16
0.53
39.7
137
305
7.3
2.86
16
0.51
36.7
59
121
307
7.6
2.90
24
1.00
34.8
120
304
2.88
7.5
26
1.00
33.8
116
295
7.3
2.81
26
0.97
31.2
120
304
7.5
2.88
23
1.00
34.2
119
301
2.86
7.5
24
0.96
33.2
115
292
7.3
2.79
25
0.92
30.7
Outdoor Ambient Temperature
129
331
7.8
2.96
24
1.00
35.5
128
328
2.94
7.7
26
0.97
34.5
124
318
7.5
2.87
26
0.93
31.8
128
328
7.7
2.94
22
0.94
35.0
126
324
2.92
7.6
23
0.90
34.0
123
315
7.4
2.85
24
0.86
31.3
63
141
349
8.0
3.06
23
0.91
37.2
139
346
3.03
8.0
24
0.87
36.1
135
335
7.7
2.96
25
0.84
33.3
139
346
8.0
3.03
19
0.76
37.4
138
342
3.01
7.9
20
0.73
36.3
134
332
7.7
2.94
21
0.70
33.5
67
150
364
8.3
3.15
20
0.74
39.7
148
361
3.13
8.2
21
0.71
38.5
144
350
8.0
3.05
21
0.68
35.6
148
361
8.2
3.13
16
0.57
40.0
147
357
3.10
8.2
16
0.55
38.8
143
346
8.0
3.03
16
0.53
35.8
71
127
350
8.1
3.05
23
1.00
34.0
126
347
3.02
8.0
25
1.00
33.0
122
336
7.8
2.95
27
1.00
30.5
126
347
8.0
3.02
23
1.00
33.4
125
343
3.00
8.0
25
0.99
32.4
121
333
7.7
2.93
25
0.95
29.9
59
135
377
8.3
3.11
24
1.00
34.6
134
373
3.09
8.2
26
1.00
33.6
130
362
8.0
3.01
26
0.96
31.0
134
373
8.2
3.09
23
0.97
34.1
133
369
3.06
8.1
23
0.93
33.1
129
358
7.9
2.99
24
0.89
30.6
63
Entering Indoor Wet Bulb Temperature
85
NOTE: Shaded area is ARI Rating Conditions
124
291
7.2
2.80
24
0.99
36.4
123
288
2.77
7.1
26
0.94
35.3
119
279
6.9
2.71
26
0.91
32.6
123
288
7.1
2.77
22
0.92
35.8
122
285
2.75
7.0
23
0.87
34.8
118
277
6.9
2.69
24
0.84
32.1
75
95
71
148
398
8.6
3.21
23
0.94
36.3
146
394
3.19
8.5
24
0.90
35.2
142
382
8.3
3.11
25
0.87
32.5
146
394
8.5
3.19
20
0.79
158
415
8.9
3.31
20
0.77
38.7
156
411
3.29
8.8
21
0.73
37.6
151
399
8.6
3.21
21
0.70
34.7
156
411
8.8
3.29
16
0.59
39.0
154
36.5
407
145
3.26
8.7
16
0.56
37.8
150
395
8.5
3.18
17
0.54
34.9
390
8.4
20
3.16
0.75
35.4
141
378
8.2
3.08
21
0.73
32.7
67
EXPANDED PERFORMANCE DATA
High and low press ures are measured at the liquid and suction service valves.
* Entering Indoor Dry Bulb Temperature
1350
1200
1050
1350
1200
1050
Airflow
65
MODEL: GSX130363 A* / CA*F3636*6C*
59
63
142
424
8.8
3.24
22
1.00
32.9
141
420
3.21
8.7
24
1.00
31.9
136
407
8.5
3.14
26
1.00
29.5
141
420
8.7
3.21
22
1.00
32.4
139
415
3.19
8.7
23
0.96
31.5
135
403
8.4
3.11
24
0.93
29.1
67
155
448
9.1
3.34
23
0.98
34.5
153
443
3.32
9.0
24
0.93
33.5
149
430
8.8
3.23
24
0.90
30.9
153
443
9.0
3.32
19
0.82
34.6
152
439
3.29
8.9
20
0.78
33.6
147
426
8.7
3.21
20
0.75
31.0
71
165
467
9.4
3.45
20
0.80
36.8
163
462
3.42
9.4
21
0.76
35.7
159
448
9.1
3.34
21
0.73
33.0
163
462
9.4
3.42
15
0.61
37.0
162
458
3.39
9.3
16
0.58
36.0
157
444
9.0
3.31
16
0.56
33.2
59
138
435
9.1
3.28
20
1.00
29.9
137
431
3.25
9.0
22
1.00
29.0
133
418
8.8
3.17
23
1.00
26.8
137
431
9.0
3.25
20
1.00
29.4
135
427
3.23
8.9
22
1.00
28.5
131
414
8.7
3.15
23
1.00
26.3
63
147
468
9.3
3.35
21
1.00
30.5
145
464
3.32
9.2
23
1.00
29.6
141
450
9.0
3.24
24
1.00
27.3
145
464
9.2
3.32
20
1.00
30.0
144
459
3.29
9.2
22
0.97
29.2
140
445
8.9
3.21
22
0.93
26.9
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
133
394
8.6
3.17
22
1.00
32.3
132
390
3.15
8.5
24
1.00
31.3
128
378
8.3
3.07
25
1.00
28.9
132
390
8.5
3.15
22
1.00
31.7
131
386
3.12
8.5
24
1.00
30.8
127
375
8.2
3.05
25
0.99
28.4
105
115
160
495
9.6
3.46
21
0.99
31.9
159
490
3.43
9.5
22
0.94
31.0
154
475
9.3
3.34
23
0.91
28.6
159
490
9.5
3.43
18
0.83
32.1
157
485
3.40
9.5
19
0.79
31.2
152
470
9.2
3.32
19
0.76
28.8
67
COOLING OPERATION
71
171
516
10.0
3.57
19
0.80
34.1
169
511
3.54
9.9
19
0.76
33.1
164
495
9.6
3.45
20
0.74
30.5
169
511
9.9
3.54
14
0.62
34.3
167
506
3.51
9.8
15
0.59
33.3
162
490
9.5
3.42
15
0.57
30.7
COOLING PERFORMANCE DATA
GSX130363A*
43
44
75
70
IDB*
22
63
0.84
21
S/T
Delta T
0.88
21
S/T
Delta T
7.2
230
110
AMPS
HI PR
LO PR
3.27
0.78
45.8
MBh
KW
47.2
109
LO PR
7.2
117
248
7.3
3.33
19
116
245
7.1
228
HI PR
3.30
20
112
AMPS
3.24
0.75
44.5
MBh
KW
45.8
105
LO PR
7.1
238
6.9
221
HI PR
3.23
20
0.72
42.3
116
245
7.2
3.30
15
0.64
46.7
114
243
7.2
3.28
16
0.61
45.4
111
235
7.0
3.21
16
0.59
41.9
AMPS
3.17
Delta T
KW
41.1
109
LO PR
0.81
228
HI PR
S/T
7.1
MBh
3.24
18
Delta T
KW
0.77
S/T
AMPS
108
45.1
225
HI PR
MBh
7.0
LO PR
3.22
18
Delta T
KW
0.73
S/T
AMPS
104
43.8
219
HI PR
MBh
6.9
LO PR
3.15
KW
19
Delta T
AMPS
0.71
S/T
59
40.4
MBh
67
127
261
7.5
3.42
15
0.59
51.1
126
259
7.5
3.40
16
0.57
49.6
122
251
7.3
3.32
16
0.55
45.8
126
259
7.5
3.40
12
0.45
51.2
125
256
7.4
3.37
12
0.43
49.7
121
249
7.2
3.30
12
0.41
45.9
136
273
7.8
3.52
11
0.38
54.8
134
270
7.7
3.50
11
0.36
53.2
130
262
7.5
3.42
11
0.35
49.1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
116
258
7.7
3.49
21
0.91
44.8
115
256
7.6
3.47
22
0.87
43.5
111
248
7.4
3.39
22
0.83
40.1
115
256
7.6
3.47
18
0.80
44.0
114
253
7.5
3.44
19
0.76
42.7
110
245
7.4
3.37
19
0.73
39.5
63
67
135
293
8.1
3.67
16
0.61
49.9
133
290
8.0
3.64
16
0.59
48.4
129
282
7.8
3.56
17
0.56
44.7
133
290
8.0
3.64
12
0.46
50.0
132
287
7.9
3.61
12
0.44
48.5
128
279
7.7
3.53
12
0.42
44.8
143
306
8.3
3.78
11
0.40
53.6
142
303
8.3
3.75
11
0.38
52.0
138
294
8.1
3.66
11
0.36
48.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
120
294
8.2
3.69
21
0.93
43.7
119
291
8.2
3.67
22
0.89
42.4
116
282
8.0
3.58
22
0.86
39.2
119
291
8.2
3.67
18
0.82
43.0
118
288
8.1
3.64
19
0.78
41.7
115
279
7.9
3.56
19
0.75
38.5
128
316
8.4
3.77
19
0.83
45.0
127
313
8.4
3.74
20
0.79
43.7
123
303
8.2
3.65
20
0.77
40.3
127
313
8.4
3.74
16
0.68
44.5
126
310
8.3
3.71
16
0.65
43.2
122
300
8.1
3.63
16
0.63
39.9
63
140
334
8.7
3.88
16
0.63
48.7
139
330
8.6
3.85
16
0.60
47.3
134
320
8.4
3.76
17
0.58
43.7
139
330
8.6
3.85
12
0.47
48.8
137
327
8.5
3.82
12
0.45
47.4
133
317
8.3
3.73
13
0.44
43.7
67
149
348
9.0
4.00
11
0.41
52.3
148
345
8.9
3.97
11
0.39
50.8
143
334
8.7
3.88
11
0.37
46.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
127
334
8.8
3.87
21
0.96
42.6
125
331
8.7
3.84
22
0.92
41.4
122
321
8.5
3.75
22
0.88
38.2
125
331
8.7
3.84
18
0.85
41.9
124
328
8.6
3.81
19
0.81
40.7
120
318
8.4
3.72
19
0.78
37.6
59
135
360
8.9
3.95
19
0.86
43.9
133
356
8.9
3.92
20
0.82
42.6
129
346
8.7
3.83
20
0.79
39.3
133
356
8.9
3.92
16
0.71
43.5
132
353
8.8
3.89
16
0.67
42.2
128
342
8.6
3.80
17
0.65
38.9
63
67
147
380
9.2
4.07
16
0.65
47.5
146
376
9.1
4.04
16
0.62
46.1
141
365
8.9
3.94
17
0.60
42.6
146
376
9.1
4.04
12
0.49
47.6
144
372
9.1
4.01
12
0.47
46.2
140
361
8.8
3.91
13
0.45
42.7
Ente r ing Indoor We t Bulb Te m pe rature
95
Outdoor Am bie nt Te m pe rature
85
NOTE: Shaded area is ACCA (TV A ) conditions
123
278
7.8
3.56
19
0.81
46.1
122
275
7.8
3.53
20
0.77
44.8
118
267
7.6
3.46
20
0.75
41.3
122
275
7.8
3.53
16
0.67
45.6
121
272
7.7
3.51
16
0.64
44.3
117
264
7.5
3.43
16
0.61
40.9
75
EXPANDED PERFORMANCE DATA
High and low pressures are measured at the liquid and suction service valves.
* Entering Indoor Dry Bulb Temperature
1800
1600
1400
1800
1600
1400
Airflow
65
MODEL: GSX130483A* / CA*F4860*6B*
157
396
9.5
4.19
11
0.42
51.0
155
392
9.5
4.16
11
0.40
49.5
150
381
9.2
4.06
12
0.38
45.7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
63
141
405
9.5
4.10
19
0.89
41.7
140
401
9.4
4.07
20
0.85
40.5
136
389
9.2
3.98
20
0.82
37.4
140
401
9.4
4.07
15
0.73
41.3
138
397
9.3
4.04
16
0.70
40.1
134
385
9.1
3.95
16
0.67
37.0
67
154
427
9.8
4.23
16
0.67
45.1
153
423
9.7
4.20
16
0.64
43.8
148
411
9.4
4.10
16
0.62
40.5
152
423
9.7
4.20
12
0.51
45.2
151
419
9.6
4.16
12
0.48
43.9
146
406
9.4
4.07
12
0.47
40.5
164
446
10.1
4.36
11
0.43
48.5
162
441
10.0
4.33
11
0.41
47.0
158
428
9.8
4.23
11
0.40
43.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
137
416
9.8
4.15
19
1.00
37.5
136
412
9.7
4.12
20
0.96
36.4
132
399
9.4
4.02
20
0.92
33.6
136
411
9.7
4.12
17
0.88
36.9
134
407
9.6
4.09
17
0.84
35.8
130
395
9.4
3.99
18
0.81
33.1
63
146
447
10.0
4.24
18
0.90
38.6
145
443
9.9
4.20
18
0.86
37.5
140
430
9.6
4.11
19
0.83
34.6
144
443
9.9
4.20
14
0.74
38.2
143
438
9.8
4.17
15
0.70
37.1
139
425
9.6
4.07
15
0.68
34.3
AMPS=outdoor unit amps (comp.+fan)
KW =Total system power
133
376
9.3
4.02
21
1.00
40.5
131
372
9.2
3.99
21
0.95
39.3
127
361
9.0
3.90
22
0.92
36.3
131
372
9.2
3.99
18
0.88
39.8
130
369
9.1
3.96
19
0.84
38.7
126
358
8.9
3.87
19
0.81
35.7
105
115
159
472
10.3
4.37
15
0.68
41.8
158
468
10.2
4.33
15
0.65
40.6
153
454
9.9
4.23
15
0.63
37.5
158
468
10.2
4.33
11
0.51
41.9
156
463
10.1
4.30
11
0.49
40.7
151
449
9.9
4.20
12
0.47
37.5
67
170
493
10.7
4.51
10
0.44
44.9
168
488
10.6
4.47
10
0.42
43.6
163
473
10.3
4.36
11
0.40
40.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130483A*
85
80
IDB*
1.00
24
S/T
Delta T
7.3
235
112
AMPS
HI PR
LO PR
3.31
47.5
MBh
KW
232
111
HI PR
LO PR
119
253
7.4
3.38
24
0.97
48.4
118
250
25
3.35
7.4
25
Delta T
0.93
47.0
243
114
7.2
25
3.28
0.89
43.4
118
7.4
250
3.35
22
117
3.29
7.2
0.96
S/T
KW
AMPS
46.1
MBh
26
3.22
Delta T
KW
7.0
0.93
S/T
225
108
42.5
MBh
HI PR
LO PR
111
LO PR
AMPS
7.2
232
23
AMPS
HI PR
0.96
S/T
Delta T
3.29
0.90
46.7
MBh
KW
47.7
110
LO PR
248
230
3.33
7.3
23
HI PR
24
Delta T
0.86
46.3
3.27
7.2
0.92
S/T
KW
AMPS
45.3
MBh
113
240
223
106
HI PR
3.26
7.1
3.20
7.0
LO PR
KW
AMPS
24
23
0.83
0.88
S/T
Delta T
63
42.7
59
41.8
MBh
67
130
267
7.6
3.47
23
0.88
50.7
129
264
3.45
7.6
24
0.84
49.2
256
125
7.4
24
3.37
0.81
45.4
129
7.6
264
3.45
19
0.73
50.9
127
261
3.42
7.5
20
0.70
49.5
124
254
3.35
7.3
20
0.67
45.6
71
138
278
7.9
3.58
20
0.71
54.1
137
275
3.55
7.8
20
0.68
52.5
267
133
7.6
21
3.47
0.65
48.5
137
7.8
275
3.55
15
0.55
54.4
136
273
3.52
7.8
16
0.52
52.9
132
265
3.45
7.6
16
0.50
48.8
59
118
263
7.8
3.54
24
1.00
46.4
117
261
3.52
7.7
26
1.00
45.0
253
114
7.5
26
3.44
0.96
41.5
117
7.7
261
3.52
23
1.00
45.6
116
258
3.49
7.7
24
0.95
44.2
112
250
3.42
7.5
25
0.92
40.8
63
126
283
8.0
3.61
24
1.00
47.3
125
281
3.59
7.9
25
0.96
45.9
272
121
7.7
26
3.51
0.93
42.4
125
7.9
281
3.59
22
0.93
46.6
123
278
3.56
7.8
23
0.89
45.2
120
269
3.48
7.6
24
0.86
41.7
75
67
137
299
8.2
3.72
23
0.91
49.5
136
296
3.69
8.1
24
0.87
48.1
287
132
7.9
24
3.61
0.84
44.4
136
8.1
296
3.69
19
0.76
49.7
135
293
3.67
8.1
20
0.72
48.3
131
285
3.58
7.9
20
0.70
44.6
71
146
312
8.5
3.83
20
0.74
52.8
145
309
3.80
8.4
21
0.70
51.3
300
140
8.2
21
3.72
0.68
47.3
145
8.4
309
3.80
15
0.57
53.2
143
306
3.78
8.3
16
0.54
51.6
139
297
3.69
8.1
16
0.52
47.7
59
123
300
8.4
3.75
23
1.00
45.3
122
297
3.72
8.3
25
1.00
43.9
288
118
8.1
26
3.64
0.98
40.6
122
8.3
297
3.72
23
1.00
44.5
120
294
3.69
8.2
24
0.97
43.2
117
285
3.61
8.0
25
0.94
39.9
131
322
8.6
3.82
24
1.00
46.1
129
319
3.80
8.5
25
0.98
44.8
310
126
8.3
26
3.71
0.95
41.3
129
8.5
319
3.80
22
0.96
45.5
128
316
3.77
8.4
23
0.91
44.1
124
306
3.68
8.2
24
0.88
40.7
143
340
8.8
3.94
23
0.93
48.3
141
337
3.91
8.8
24
0.89
46.9
327
137
8.5
24
3.82
0.86
43.3
141
8.8
337
3.91
19
0.78
48.6
140
334
3.88
8.7
20
0.74
47.2
136
324
3.79
8.5
20
0.72
43.5
152
355
9.1
4.06
20
0.76
51.6
151
351
4.03
9.0
21
0.72
50.1
341
146
8.8
21
3.94
0.70
46.2
151
9.0
351
4.03
15
0.58
51.9
149
348
4.00
9.0
16
0.56
50.4
145
338
3.91
8.7
16
0.54
46.5
129
341
8.9
3.93
23
1.00
44.2
128
338
3.90
8.8
25
1.00
42.9
328
124
8.6
26
3.81
1.00
39.6
128
8.8
338
3.90
22
1.00
43.4
127
334
3.87
8.8
24
1.00
42.1
123
324
3.78
8.5
25
0.97
38.9
137
367
9.1
4.01
23
1.00
45.0
136
363
3.98
9.0
25
1.00
43.7
353
132
8.8
26
3.89
0.98
40.3
136
9.0
363
3.98
23
1.00
44.3
135
360
3.95
8.9
23
0.94
43.1
131
349
3.86
8.7
24
0.91
39.7
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
85
Outdoor Ambient Temperature
95
150
388
9.4
4.13
23
0.96
47.1
148
384
4.10
9.3
24
0.92
45.8
372
144
9.1
25
4.01
0.88
42.2
148
9.3
384
4.10
19
0.80
47.4
380
147
9.2
20
4.07
0.77
46.0
143
369
3.97
9.0
21
0.74
42.5
67
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction service valves.
1800
1600
1400
1800
1600
1400
Airflow
65
MODEL: GSX130483A* / CA*F4860*6B*
71
160
404
9.7
4.26
20
0.78
50.3
158
400
4.23
9.6
21
0.74
48.8
388
153
9.4
21
4.13
0.72
45.1
158
9.6
400
4.23
16
0.60
50.6
157
396
4.20
9.5
16
0.57
49.2
152
384
4.10
9.3
16
0.55
45.4
59
63
144
413
9.6
4.17
22
1.00
42.8
143
409
4.14
9.6
24
1.00
41.5
397
138
9.3
25
4.04
1.00
38.3
143
9.6
409
4.14
22
1.00
42.1
141
405
4.10
9.5
23
0.98
40.9
137
393
4.01
9.2
23
0.94
37.8
67
157
436
9.9
4.30
23
1.00
44.8
156
432
4.26
9.8
24
0.95
43.5
419
151
9.6
24
4.16
0.92
40.1
156
9.8
432
4.26
19
0.83
45.0
154
428
4.23
9.8
20
0.80
43.7
149
415
4.13
9.5
20
0.77
40.3
71
167
455
10.3
4.43
20
0.81
47.8
166
450
4.40
10.2
21
0.77
46.4
437
161
9.9
21
4.29
0.74
42.8
166
10.2
450
4.40
15
0.62
48.1
164
446
4.36
10.1
16
0.60
46.7
159
433
4.26
9.8
16
0.57
43.1
59
140
424
9.9
4.22
20
1.00
38.9
139
420
4.18
9.8
22
1.00
37.7
407
134
9.6
23
4.09
1.00
34.8
139
9.8
420
4.18
20
1.00
38.2
137
416
4.15
9.8
21
1.00
37.1
133
403
4.05
9.5
23
1.01
34.2
63
149
456
10.2
4.30
20
1.00
39.6
147
452
4.27
10.1
22
1.00
38.5
438
143
9.8
23
4.17
1.00
35.5
147
10.1
452
4.27
20
1.00
39.0
146
447
4.24
10.0
21
0.99
37.9
142
434
4.14
9.7
22
0.95
35.0
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
135
384
9.4
4.08
21
1.00
42.0
134
380
4.05
9.3
23
1.00
40.7
369
130
9.1
25
3.96
1.00
37.6
134
9.3
380
4.05
21
1.00
41.2
133
376
4.02
9.3
23
1.00
40.0
129
365
3.93
9.0
24
1.01
36.9
105
115
163
482
10.5
4.44
21
1.00
41.5
161
477
4.40
10.4
22
0.96
40.3
463
156
10.1
23
4.30
0.93
37.2
161
10.4
477
4.40
18
0.84
41.7
159
472
4.37
10.3
19
0.80
40.5
155
458
4.26
10.0
19
0.77
37.4
67
COOLING OPERATION
71
173
503
10.8
4.58
18
0.82
44.3
171
498
4.54
10.7
19
0.78
43.0
483
166
10.5
20
4.43
0.75
39.7
171
10.7
498
4.54
14
0.63
44.6
170
493
4.51
10.7
15
0.60
43.3
165
478
4.40
10.4
15
0.58
39.9
COOLING PERFORMANCE DATA
GSX130483A*
45
46
75
70
IDB*
228
109
41.1
0.81
22
HI PR
LO PR
MBh
S/T
Delta T
63
21
S/T
Delta T
21
S/T
Delta T
3.9
230
110
AMPS
HI PR
LO PR
3.26
0.78
0.88
MBh
KW
47.2
109
45.8
LO PR
3.9
117
248
4.0
3.33
19
116
245
3.9
228
HI PR
3.30
20
112
AMPS
3.24
0.75
0.84
MBh
KW
45.8
105
44.5
LO PR
3.8
238
3.8
221
HI PR
3.23
20
0.72
42.3
116
245
3.9
3.30
15
0.64
46.7
114
243
3.9
3.28
16
0.61
45.4
111
235
3.8
3.21
16
0.59
41.9
AMPS
3.17
3.9
KW
3.24
18
Delta T
KW
0.77
S/T
AMPS
108
45.1
225
HI PR
MBh
3.8
LO PR
3.22
18
Delta T
KW
0.73
S/T
AMPS
104
43.8
219
HI PR
MBh
3.7
LO PR
3.15
KW
19
Delta T
AMPS
0.71
S/T
59
40.4
MBh
67
273
136
127
4.2
3.52
11
0.38
54.8
134
270
4.2
3.50
11
0.36
53.2
130
262
4.1
3.42
11
0.35
49.1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
261
4.1
3.42
15
0.59
51.1
126
259
4.0
3.40
16
0.57
49.6
122
251
3.9
3.32
16
0.55
45.8
126
259
4.0
3.40
12
0.45
51.2
125
256
4.0
3.37
12
0.43
49.7
121
249
3.9
3.30
12
0.41
45.9
59
116
258
4.2
3.49
21
0.91
44.8
115
256
4.1
3.47
22
0.87
43.5
111
248
4.0
3.39
22
0.83
40.1
115
256
4.1
3.47
18
0.80
44.0
114
253
4.1
3.44
19
0.76
42.7
110
245
4.0
3.36
19
0.73
39.5
63
67
135
293
4.4
3.66
16
0.61
49.9
133
290
4.3
3.64
16
0.59
48.4
129
282
4.2
3.56
17
0.56
44.7
133
290
4.3
3.64
12
0.46
50.0
132
287
4.3
3.61
12
0.44
48.5
128
279
4.2
3.53
12
0.42
44.8
143
306
4.5
3.77
11
0.40
53.6
142
303
4.5
3.75
11
0.38
52.0
138
294
4.4
3.66
11
0.36
48.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
120
294
4.5
3.69
21
0.93
43.7
119
291
4.4
3.67
22
0.89
42.4
116
282
4.3
3.58
22
0.86
39.2
119
291
4.4
3.66
18
0.82
43.0
118
288
4.4
3.64
19
0.78
41.7
115
279
4.3
3.56
19
0.75
38.5
128
316
4.6
3.77
19
0.83
45.0
127
313
4.5
3.74
20
0.79
43.7
123
303
4.4
3.65
20
0.77
40.3
127
313
4.5
3.74
16
0.68
44.5
126
310
4.5
3.71
16
0.65
43.2
122
300
4.4
3.63
16
0.63
39.9
63
140
334
4.7
3.88
16
0.63
48.7
139
330
4.7
3.85
16
0.60
47.3
134
320
4.6
3.76
17
0.58
43.7
139
330
4.7
3.85
12
0.47
48.8
137
327
4.6
3.82
12
0.45
47.4
133
317
4.5
3.73
13
0.44
43.7
67
149
348
4.9
4.00
11
0.41
52.3
148
345
4.8
3.97
11
0.39
50.8
143
334
4.7
3.88
11
0.37
46.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
127
334
4.8
3.87
21
0.96
42.6
125
331
4.7
3.84
22
0.92
41.4
122
321
4.6
3.75
22
0.88
38.2
125
331
4.7
3.84
18
0.85
41.9
124
328
4.7
3.81
19
0.81
40.7
120
318
4.6
3.72
19
0.78
37.6
59
135
360
4.9
3.95
19
0.86
43.9
133
356
4.8
3.92
20
0.82
42.6
129
346
4.7
3.83
20
0.79
39.3
133
356
4.8
3.92
16
0.71
43.5
132
353
4.8
3.89
16
0.67
42.2
128
342
4.7
3.80
17
0.65
38.9
63
67
147
380
5.0
4.07
16
0.65
47.5
146
376
5.0
4.04
16
0.62
46.1
141
365
4.8
3.94
17
0.60
42.6
146
376
5.0
4.04
12
0.49
47.6
144
372
4.9
4.01
12
0.47
46.2
140
361
4.8
3.91
13
0.45
42.7
Ente ring Indoor We t Bulb Te m pe rature
95
Outdoor Am bie nt Te m pe rature
85
NOTE: Shaded area is A CCA (TV A) conditions
123
278
4.2
3.56
19
0.81
46.1
122
275
4.2
3.53
20
0.77
44.8
118
267
4.1
3.46
20
0.75
41.3
122
275
4.2
3.53
16
0.67
45.6
121
272
4.2
3.51
16
0.64
44.3
117
264
4.1
3.43
16
0.61
40.9
75
EXPANDED PERFORMANCE DATA
High and low pressures are measured at the liquid and suction service valves.
* Entering Indoor Dry Bulb Temperature
1800
1600
1400
1800
1600
1400
Airflow
65
MODEL: GSX130484 A* / CA*F4860*6B*
157
396
5.2
4.19
11
0.42
51.0
155
392
5.1
4.16
11
0.40
49.5
150
381
5.0
4.06
12
0.38
45.7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
63
141
405
5.1
4.10
19
0.89
41.7
140
401
5.1
4.07
20
0.85
40.5
136
389
5.0
3.98
20
0.82
37.4
140
401
5.1
4.07
15
0.73
41.3
138
397
5.1
4.04
16
0.70
40.1
134
385
4.9
3.95
16
0.67
37.0
67
154
427
5.3
4.23
16
0.67
45.1
153
423
5.3
4.20
16
0.64
43.8
148
411
5.1
4.10
16
0.62
40.5
152
423
5.3
4.20
12
0.51
45.2
151
419
5.2
4.16
12
0.48
43.9
146
406
5.1
4.07
12
0.47
40.5
164
446
5.5
4.36
11
0.43
48.5
162
441
5.4
4.33
11
0.41
47.0
158
428
5.3
4.23
11
0.40
43.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
137
416
5.3
4.15
19
1.00
37.5
136
412
5.3
4.12
20
0.96
36.4
132
399
5.1
4.02
20
0.92
33.6
136
411
5.3
4.12
17
0.88
36.9
134
407
5.2
4.09
17
0.84
35.8
130
395
5.1
3.99
18
0.81
33.1
63
146
447
5.4
4.24
18
0.90
38.6
145
443
5.4
4.20
18
0.86
37.5
140
430
5.2
4.11
19
0.83
34.6
144
443
5.4
4.20
14
0.74
38.2
143
438
5.3
4.17
15
0.70
37.1
139
425
5.2
4.07
15
0.68
34.3
AMPS=outdoor unit amps (comp.+fan)
KW =Total system power
133
376
5.0
4.02
21
1.00
40.5
131
372
5.0
3.99
21
0.95
39.3
127
361
4.9
3.90
22
0.92
36.3
131
372
5.0
3.99
18
0.88
39.8
130
369
4.9
3.96
19
0.84
38.7
126
358
4.8
3.87
19
0.81
35.7
105
115
159
472
5.6
4.37
15
0.68
41.8
158
468
5.5
4.33
15
0.65
40.6
153
454
5.4
4.23
15
0.63
37.5
158
468
5.5
4.33
11
0.51
41.9
156
463
5.5
4.30
11
0.49
40.7
151
449
5.4
4.20
12
0.47
37.5
67
170
493
5.8
4.51
10
0.44
44.9
168
488
5.7
4.47
10
0.42
43.6
163
473
5.6
4.36
11
0.40
40.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130484A*
85
80
IDB*
46.3
0.86
45.3
0.92
24
MBh
S/T
Delta T
240
24
3.9
235
112
AMPS
HI PR
LO PR
3.31
0.97
1.00
S/T
Delta T
KW
48.4
47.5
MBh
119
253
4.0
3.38
24
118
232
111
HI PR
LO PR
250
25
3.35
4.0
25
Delta T
0.93
47.0
243
114
3.9
25
3.28
0.89
43.4
118
4.0
250
3.35
22
117
3.29
3.9
0.96
S/T
KW
AMPS
46.1
MBh
26
3.22
Delta T
KW
3.8
0.93
S/T
225
108
42.5
MBh
HI PR
LO PR
111
LO PR
AMPS
3.9
232
23
AMPS
HI PR
0.96
S/T
Delta T
3.29
0.90
46.7
MBh
KW
47.7
110
LO PR
248
230
HI PR
3.33
4.0
3.26
3.9
KW
AMPS
23
113
223
106
HI PR
3.25
3.9
3.19
3.8
LO PR
KW
AMPS
24
23
0.83
0.88
S/T
Delta T
63
42.7
59
41.8
MBh
67
130
267
4.1
3.47
23
0.88
50.7
129
264
3.45
4.1
24
0.84
49.2
256
125
4.0
24
3.37
0.81
45.4
129
4.1
264
3.45
19
0.73
50.9
127
261
3.42
4.1
20
0.70
49.5
124
254
3.35
4.0
20
0.67
45.6
71
138
278
4.3
3.57
20
0.71
54.1
137
275
3.55
4.2
20
0.68
52.5
267
133
4.1
21
3.47
0.65
48.5
137
4.2
275
3.55
15
0.55
54.4
136
273
3.52
4.2
16
0.52
52.9
132
265
3.44
4.1
16
0.50
48.8
59
118
263
4.2
3.54
24
1.00
46.4
117
261
3.52
4.2
26
1.00
45.0
253
114
4.1
26
3.44
0.96
41.5
117
4.2
261
3.52
23
1.00
45.6
116
258
3.49
4.2
24
0.95
44.2
112
250
3.41
4.1
25
0.92
40.8
63
126
283
4.3
3.61
24
1.00
47.3
125
281
3.59
4.3
25
0.96
45.9
272
121
4.2
26
3.51
0.93
42.4
125
4.3
281
3.59
22
0.93
46.6
123
278
3.56
4.2
23
0.89
45.2
120
269
3.48
4.1
24
0.86
41.7
75
67
137
299
4.4
3.72
23
0.91
49.5
136
296
3.69
4.4
24
0.87
48.1
287
132
4.3
24
3.61
0.84
44.4
136
4.4
296
3.69
19
0.76
49.7
135
293
3.67
4.4
20
0.72
48.3
131
285
3.58
4.3
20
0.70
44.6
71
146
312
4.6
3.83
20
0.74
52.8
145
309
3.80
4.6
21
0.70
51.3
300
140
4.4
21
3.72
0.68
47.3
145
4.6
309
3.80
15
0.57
53.2
143
306
3.78
4.5
16
0.54
51.6
139
297
3.69
4.4
16
0.52
47.7
59
123
300
4.6
3.75
23
1.00
45.3
122
297
3.72
4.5
25
1.00
43.9
288
118
4.4
26
3.64
0.98
40.6
122
4.5
297
3.72
23
1.00
44.5
120
294
3.69
4.5
24
0.97
43.2
117
285
3.61
4.4
25
0.94
39.9
131
322
4.7
3.82
24
1.00
46.1
129
319
3.80
4.6
25
0.98
44.8
310
126
4.5
26
3.71
0.95
41.3
129
4.6
319
3.80
22
0.96
45.5
128
316
3.77
4.6
23
0.91
44.1
124
306
3.68
4.5
24
0.88
40.7
355
152
143
5.0
4.06
20
0.76
51.6
151
351
4.03
4.9
21
0.72
50.1
341
146
4.8
21
3.94
0.70
46.2
151
4.9
351
4.03
15
0.58
51.9
149
348
4.00
4.9
16
0.56
50.4
145
338
3.91
4.8
16
0.54
46.5
340
4.8
3.94
23
0.93
48.3
141
337
3.91
4.8
24
0.89
46.9
327
137
4.6
24
3.82
0.86
43.3
141
4.8
337
3.91
19
0.78
48.6
140
334
3.88
4.7
20
0.74
47.2
136
324
3.79
4.6
20
0.72
43.5
129
341
4.8
3.93
23
1.00
44.2
128
338
3.90
4.8
25
1.00
42.9
328
124
4.7
26
3.81
1.00
39.6
128
4.8
338
3.90
22
1.00
43.4
127
334
3.87
4.8
24
1.00
42.1
123
324
3.78
4.6
25
0.97
38.9
137
367
4.9
4.01
23
1.00
45.0
136
363
3.98
4.9
25
1.00
43.7
353
132
4.8
26
3.89
0.98
40.3
136
4.9
363
3.98
23
1.00
44.3
135
360
3.95
4.9
23
0.94
43.1
131
349
3.86
4.7
24
0.91
39.7
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
85
Outdoor Ambient Temperature
95
150
388
5.1
4.13
23
0.96
47.1
148
384
4.10
5.1
24
0.92
45.8
372
144
4.9
25
4.00
0.88
42.2
148
5.1
384
4.10
19
0.80
47.4
380
147
5.0
20
4.07
0.77
46.0
143
369
3.97
4.9
21
0.74
42.5
67
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction service valves.
1800
1600
1400
1800
1600
1400
Airflow
65
MODEL: GSX130484 A* / CA*F4860*6B*
71
160
404
5.3
4.26
20
0.78
50.3
158
400
4.23
5.2
21
0.74
48.8
388
153
5.1
21
4.13
0.72
45.1
158
5.2
400
4.23
16
0.60
50.6
157
396
4.20
5.2
16
0.57
49.2
152
384
4.10
5.1
16
0.55
45.4
59
63
144
413
5.2
4.17
22
1.00
42.8
143
409
4.14
5.2
24
1.00
41.5
397
138
5.1
25
4.04
1.00
38.3
143
5.2
409
4.14
22
1.00
42.1
141
405
4.10
5.1
23
0.98
40.9
137
393
4.01
5.0
23
0.94
37.8
67
157
436
5.4
4.30
23
1.00
44.8
156
432
4.26
5.3
24
0.95
43.5
419
151
5.2
24
4.16
0.92
40.1
156
5.3
432
4.26
19
0.83
45.0
154
428
4.23
5.3
20
0.80
43.7
149
415
4.13
5.2
20
0.77
40.3
71
167
455
5.6
4.43
20
0.81
47.8
166
450
4.40
5.5
21
0.77
46.4
437
161
5.4
21
4.29
0.74
42.8
166
5.5
450
4.40
15
0.62
48.1
164
446
4.36
5.5
16
0.60
46.7
159
433
4.26
5.3
16
0.57
43.1
59
140
424
5.4
4.22
20
1.00
38.9
139
420
4.18
5.4
22
1.00
37.7
407
134
5.2
23
4.09
1.00
34.8
139
5.4
420
4.18
20
1.00
38.2
137
416
4.15
5.3
21
1.00
37.1
133
403
4.05
5.2
23
1.01
34.2
63
149
456
5.5
4.30
20
1.00
39.6
147
452
4.27
5.5
22
1.00
38.5
438
143
5.3
23
4.17
1.00
35.5
147
5.5
452
4.27
20
1.00
39.0
146
447
4.24
5.4
21
0.99
37.9
142
434
4.14
5.3
22
0.95
35.0
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
135
384
5.1
4.08
21
1.00
42.0
134
380
4.05
5.1
23
1.00
40.7
369
130
4.9
25
3.96
1.00
37.6
134
5.1
380
4.05
21
1.00
41.2
133
376
4.02
5.0
23
1.00
40.0
129
365
3.93
4.9
24
1.01
36.9
105
115
163
482
5.7
4.44
21
1.00
41.5
161
477
4.40
5.6
22
0.96
40.3
463
156
5.5
23
4.30
0.93
37.2
161
5.6
477
4.40
18
0.84
41.7
159
472
4.37
5.6
19
0.80
40.5
155
458
4.27
5.5
19
0.77
37.4
67
COOLING OPERATION
71
173
503
5.9
4.58
18
0.82
44.3
171
498
4.54
5.8
19
0.78
43.0
483
166
5.7
20
4.43
0.75
39.7
171
5.8
498
4.54
14
0.63
44.6
170
493
4.51
5.8
15
0.60
43.3
165
478
4.40
5.6
15
0.58
39.9
COOLING PERFORMANCE DATA
GSX130484A*
47
48
75
70
IDB*
107
50.9
0.76
24
LO PR
MBh
S/T
Delta T
63
0.79
23
S/T
Delta T
0.83
22
S/T
Delta T
9.5
242
108
AMPS
HI PR
LO PR
4.17
0.74
56.8
MBh
KW
58.5
107
LO PR
9.6
115
260
9.7
4.25
20
114
257
9.4
239
HI PR
4.22
21
111
AMPS
4.15
0.71
55.1
MBh
KW
56.8
104
LO PR
9.4
250
9.2
232
HI PR
4.13
22
0.68
52.4
114
257
9.6
4.22
16
0.61
57.9
113
255
9.5
4.19
17
0.58
56.2
109
247
9.3
4.10
18
0.56
51.9
AMPS
4.06
239
HI PR
KW
9.4
AMPS
19
Delta T
4.14
0.73
S/T
KW
106
55.9
MBh
237
HI PR
LO PR
9.3
AMPS
20
Delta T
4.12
0.69
S/T
KW
103
54.2
MBh
230
HI PR
LO PR
9.1
AMPS
21
4.03
Delta T
KW
0.67
S/T
59
50.1
MBh
67
126
274
10.0
4.37
16
0.56
63.3
124
272
9.9
4.34
17
0.53
61.5
121
264
9.7
4.25
18
0.51
56.7
124
272
9.9
4.34
12
0.42
63.4
123
269
9.8
4.31
13
0.40
61.6
120
261
9.6
4.22
13
0.39
56.8
134
286
10.4
4.50
11
0.36
67.9
133
283
10.3
4.46
12
0.34
66.0
129
275
10.0
4.37
12
0.33
60.9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
114
271
10.2
4.46
22
0.86
55.5
113
268
10.1
4.43
23
0.82
53.9
110
260
9.9
4.33
24
0.79
49.7
113
268
10.1
4.43
19
0.75
54.6
112
266
10.0
4.39
20
0.72
53.0
109
258
9.8
4.30
21
0.69
48.9
63
67
133
308
10.8
4.67
16
0.58
61.8
131
305
10.7
4.64
17
0.55
60.0
128
296
10.4
4.54
18
0.53
55.4
131
305
10.7
4.64
12
0.44
62.0
130
302
10.6
4.61
13
0.42
60.1
126
293
10.3
4.50
14
0.40
55.5
141
321
11.2
4.81
11
0.37
66.4
140
318
11.1
4.77
12
0.36
64.4
136
309
10.8
4.67
13
0.34
59.5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
119
308
11.1
4.71
22
0.88
54.2
118
305
11.0
4.67
23
0.84
52.6
114
296
10.7
4.57
24
0.81
48.5
118
305
11.0
4.67
19
0.77
53.3
116
302
10.9
4.64
20
0.74
51.7
113
293
10.6
4.54
21
0.71
47.7
126
332
11.3
4.80
20
0.79
55.8
125
328
11.2
4.76
21
0.75
54.1
121
319
10.9
4.66
22
0.72
50.0
125
328
11.2
4.76
16
0.65
55.2
124
325
11.1
4.73
17
0.62
53.6
120
315
10.8
4.62
18
0.59
49.5
63
138
350
11.7
4.94
16
0.59
60.4
137
347
11.6
4.90
17
0.57
58.6
133
336
11.3
4.79
18
0.55
54.1
137
347
11.6
4.90
12
0.45
60.5
135
343
11.5
4.87
13
0.43
58.7
131
333
11.2
4.76
14
0.41
54.2
67
147
365
12.1
5.09
11
0.38
64.8
146
362
12.0
5.05
12
0.36
62.9
141
351
11.7
4.94
13
0.35
58.1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
125
351
11.8
4.93
22
0.91
52.8
124
348
11.7
4.89
23
0.86
51.3
120
337
11.4
4.78
24
0.83
47.3
124
348
11.7
4.89
19
0.80
52.0
122
344
11.6
4.86
20
0.76
50.4
119
334
11.3
4.75
21
0.73
46.6
59
133
378
12.1
5.03
20
0.81
54.4
131
374
12.0
4.99
21
0.77
52.8
128
363
11.7
4.88
22
0.75
48.8
131
374
12.0
4.99
16
0.67
53.9
130
370
11.9
4.95
17
0.64
52.3
126
359
11.6
4.84
18
0.61
48.3
63
67
145
399
12.5
5.18
17
0.61
58.9
144
395
12.4
5.14
18
0.59
57.2
139
383
12.0
5.02
18
0.56
52.8
144
395
12.4
5.14
13
0.46
59.0
142
391
12.3
5.10
13
0.44
57.3
138
379
11.9
4.98
14
0.42
52.9
Ente ring Indoor We t Bulb Te m pe rature
95
Outdoor Am bie nt Te m pe rature
85
NOTE: Shaded area is ACCA (TVA ) conditions
122
292
10.5
4.54
20
0.77
57.1
120
289
10.4
4.51
21
0.73
55.5
117
280
10.1
4.41
22
0.70
51.2
120
289
10.4
4.51
16
0.63
56.5
119
286
10.3
4.48
17
0.60
54.9
116
277
10.0
4.38
18
0.58
50.7
75
EXPANDED PERFORMANCE DATA
High and low pressures are measured at the liquid and suction service valves.
* Entering Indoor Dry Bulb Temperature
2000
1750
1500
2000
1750
1500
Airflow
65
MODEL: GSX130603 A* / CA*F4961*6A*
154
416
12.9
5.33
11
0.39
63.2
153
412
12.8
5.29
12
0.38
61.4
148
400
12.5
5.17
13
0.36
56.6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
63
139
425
12.9
5.22
20
0.84
51.7
138
421
12.7
5.18
21
0.80
50.2
134
408
12.4
5.06
22
0.77
46.3
138
421
12.7
5.18
16
0.69
51.2
136
417
12.6
5.14
17
0.66
49.7
132
404
12.3
5.02
18
0.64
45.8
67
152
449
13.3
5.38
16
0.64
55.9
150
444
13.2
5.33
17
0.61
54.3
146
431
12.8
5.21
18
0.59
50.1
150
444
13.2
5.33
12
0.48
56.1
149
440
13.0
5.29
13
0.46
54.4
144
427
12.7
5.17
14
0.44
50.2
162
468
13.8
5.54
11
0.41
60.0
160
463
13.6
5.50
12
0.39
58.3
155
450
13.3
5.37
12
0.38
53.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
135
436
13.3
5.28
20
0.95
46.5
134
432
13.2
5.24
21
0.91
45.1
130
419
12.8
5.12
22
0.87
41.7
134
432
13.2
5.24
18
0.83
45.7
133
428
13.0
5.20
19
0.80
44.4
129
415
12.7
5.08
19
0.77
41.0
63
144
470
13.6
5.39
19
0.85
47.9
143
465
13.5
5.34
20
0.81
46.5
138
451
13.1
5.22
21
0.78
42.9
143
465
13.5
5.34
15
0.70
47.4
141
460
13.4
5.30
16
0.66
46.0
137
446
13.0
5.18
17
0.64
42.5
AMPS=outdoor unit amps (comp.+fan)
KW =Total system power
131
395
12.6
5.12
22
0.94
50.2
130
391
12.4
5.08
23
0.90
48.7
126
379
12.1
4.96
24
0.87
45.0
130
391
12.4
5.08
19
0.83
49.4
128
387
12.3
5.04
20
0.79
47.9
124
375
12.0
4.93
21
0.76
44.2
105
115
157
496
14.0
5.55
15
0.64
51.8
156
491
13.9
5.51
16
0.61
50.3
151
476
13.5
5.38
17
0.59
46.4
156
491
13.9
5.51
12
0.48
51.9
154
486
13.8
5.46
12
0.46
50.4
149
471
13.4
5.34
13
0.44
46.5
67
167
517
14.6
5.72
11
0.41
55.6
166
512
14.4
5.68
11
0.39
54.0
161
497
14.0
5.54
12
0.38
49.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130603A*
85
80
IDB*
252
234
105
56.1
0.86
25
HI PR
LO PR
MBh
S/T
Delta T
0.95
26
S/T
Delta T
9.6
246
110
AMPS
HI PR
LO PR
4.23
58.8
MBh
KW
263
109
117
265
9.9
4.31
25
0.92
60.0
116
244
HI PR
LO PR
27
4.28
9.8
27
Delta T
0.87
58.2
255
113
9.5
28
4.19
0.84
53.7
116
9.8
263
4.28
23
115
4.20
9.6
0.91
S/T
KW
AMPS
57.1
MBh
28
4.12
Delta T
KW
9.3
0.87
S/T
237
106
52.7
MBh
HI PR
LO PR
109
LO PR
AMPS
9.6
244
24
AMPS
HI PR
0.91
S/T
Delta T
4.20
0.85
57.8
MBh
KW
59.1
108
LO PR
260
242
HI PR
4.25
9.7
4.17
9.5
KW
AMPS
24
0.81
57.4
112
4.16
9.4
4.09
9.2
KW
AMPS
26
25
0.78
0.83
S/T
Delta T
63
52.9
59
51.8
MBh
67
128
280
10.2
4.43
24
0.83
62.8
127
277
4.40
10.1
25
0.79
61.0
269
123
9.8
26
4.31
0.76
56.3
127
10.1
277
4.40
20
0.69
63.1
126
275
4.37
10.0
21
0.66
61.3
122
266
4.28
9.7
22
0.64
56.6
71
137
292
10.5
4.56
21
0.67
67.0
135
289
4.53
10.5
22
0.64
65.0
281
131
10.2
23
4.43
0.62
60.0
135
10.5
289
4.53
16
0.52
67.5
134
286
4.50
10.4
17
0.49
65.5
130
278
4.40
10.1
18
0.48
60.5
59
117
277
10.4
4.52
26
0.99
57.5
116
274
4.49
10.3
28
0.94
55.8
266
112
10.0
29
4.39
0.91
51.5
116
10.3
274
4.49
24
0.94
56.5
114
271
4.46
10.2
26
0.90
54.8
111
263
4.36
10.0
27
0.86
50.6
63
124
298
10.6
4.61
26
0.95
58.6
123
295
4.58
10.6
27
0.91
56.9
286
119
10.3
28
4.48
0.87
52.5
123
10.6
295
4.58
23
0.88
57.7
122
292
4.54
10.5
25
0.84
56.0
118
283
4.44
10.2
26
0.81
51.7
75
67
135
314
11.0
4.74
24
0.86
61.3
134
311
4.71
10.9
26
0.82
59.6
302
130
10.6
27
4.60
0.79
55.0
134
10.9
311
4.71
20
0.72
61.6
133
308
4.67
10.8
22
0.68
59.9
129
299
4.57
10.5
22
0.66
55.2
71
144
328
11.4
4.88
21
0.70
65.4
143
324
4.85
11.3
22
0.66
63.5
315
139
11.0
23
4.74
0.64
58.6
143
11.3
324
4.85
16
0.54
65.9
141
321
4.81
11.2
17
0.51
64.0
137
312
4.70
10.9
18
0.49
59.1
59
121
314
11.3
4.78
26
1.00
56.1
120
311
4.74
11.2
28
0.96
54.5
302
116
10.9
29
4.64
0.93
50.3
120
11.2
311
4.74
24
0.96
55.1
119
308
4.71
11.1
26
0.92
53.5
115
299
4.60
10.8
27
0.89
49.4
129
338
11.5
4.87
26
0.97
57.2
128
335
4.84
11.4
27
0.93
55.5
325
124
11.1
28
4.73
0.90
51.2
128
11.4
335
4.84
23
0.90
56.3
126
332
4.80
11.3
25
0.86
54.7
123
322
4.69
11.0
26
0.83
50.5
141
357
11.9
5.01
24
0.88
59.9
139
354
4.98
11.8
26
0.84
58.1
343
135
11.5
27
4.87
0.81
53.7
139
11.8
354
4.98
20
0.74
60.2
138
350
4.94
11.7
22
0.70
58.4
134
340
4.83
11.4
22
0.68
53.9
150
373
12.4
5.17
21
0.71
63.9
148
369
5.13
12.2
22
0.68
62.0
358
144
11.9
23
5.01
0.66
57.2
148
12.2
369
5.13
16
0.55
64.3
147
365
5.09
12.1
17
0.52
62.5
143
354
4.97
11.8
18
0.51
57.6
127
358
12.0
5.00
25
1.00
54.7
126
355
4.97
11.9
28
0.99
53.1
344
122
11.6
29
4.85
0.96
49.0
126
11.9
355
4.97
25
1.00
53.8
125
351
4.93
11.8
26
0.95
52.2
121
341
4.82
11.5
27
0.91
48.2
135
385
12.3
5.10
26
1.00
55.8
134
382
5.06
12.2
27
0.96
54.2
370
130
11.9
28
4.95
0.93
50.0
134
12.2
382
5.06
24
0.93
55.0
133
378
5.03
12.1
25
0.89
53.4
129
367
4.91
11.8
26
0.86
49.2
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
85
Outdoor Ambient Temperature
95
148
407
12.7
5.25
24
0.91
58.4
146
403
5.22
12.6
26
0.87
56.7
391
142
12.3
27
5.10
0.83
52.3
146
12.6
403
5.22
20
0.76
58.7
399
145
12.5
22
5.18
0.72
57.0
141
387
5.06
12.2
23
0.70
52.6
67
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction service valves.
2000
1750
1500
2000
1750
1500
Airflow
65
MODEL: GSX130603 A* / CA*F4961*6A*
71
158
425
13.2
5.42
21
0.74
62.3
156
420
5.37
13.1
22
0.70
60.5
408
151
12.7
23
5.25
0.68
55.8
156
13.1
420
5.37
16
0.57
62.8
154
416
5.33
13.0
17
0.54
60.9
150
404
5.21
12.6
18
0.52
56.2
59
63
142
434
13.1
5.30
24
1.00
53.0
141
429
5.26
13.0
27
1.00
51.4
416
136
12.6
28
5.14
0.96
47.5
141
13.0
429
5.26
23
0.97
52.2
139
425
5.22
12.9
25
0.92
50.7
135
412
5.10
12.5
26
0.89
46.8
67
155
458
13.5
5.46
24
0.94
55.5
153
453
5.42
13.4
25
0.90
53.9
440
149
13.0
26
5.29
0.87
49.7
153
13.4
453
5.42
20
0.79
55.8
152
449
5.38
13.3
21
0.75
54.2
147
435
5.25
12.9
22
0.72
50.0
71
165
478
14.0
5.63
21
0.76
59.2
163
473
5.58
13.9
22
0.73
57.5
459
159
13.5
23
5.45
0.70
53.1
163
13.9
473
5.58
16
0.59
59.6
162
468
5.54
13.8
17
0.56
57.9
157
454
5.41
13.4
18
0.54
53.4
59
138
445
13.5
5.36
22
1.00
48.2
137
441
5.32
13.4
25
1.00
46.7
428
133
13.0
26
5.20
1.00
43.1
137
13.4
441
5.32
22
1.00
47.3
135
436
5.28
13.3
24
0.99
45.9
131
423
5.16
12.9
25
0.96
42.4
63
147
479
13.9
5.47
23
1.00
49.1
145
474
5.43
13.7
25
1.00
47.7
460
141
13.4
26
5.30
0.97
44.0
145
13.7
474
5.43
22
1.00
48.4
144
470
5.39
13.6
23
0.93
46.9
140
456
5.26
13.2
24
0.90
43.3
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
133
403
12.8
5.19
24
1.00
52.0
132
399
5.15
12.7
27
1.00
50.5
387
128
12.3
28
5.04
1.00
46.6
132
12.7
399
5.15
23
1.00
51.1
131
395
5.12
12.6
26
0.98
49.6
127
383
5.00
12.2
27
0.95
45.8
105
115
160
506
14.3
5.64
22
0.95
51.4
159
501
5.59
14.2
24
0.91
49.9
486
154
13.8
25
5.46
0.87
46.1
159
14.2
501
5.59
19
0.79
51.7
157
496
5.55
14.1
20
0.76
50.2
152
481
5.42
13.7
21
0.73
46.3
67
COOLING OPERATION
71
171
528
14.8
5.81
19
0.77
54.8
169
522
5.77
14.7
21
0.74
53.2
507
164
14.3
21
5.63
0.71
49.1
169
14.7
522
5.77
15
0.59
55.2
167
517
5.72
14.6
16
0.57
53.6
162
502
5.59
14.2
17
0.55
49.5
COOLING PERFORMANCE DATA
GSX130603A*
49
50
75
70
IDB*
21
20
Delta T
19
Delta T
50.9
0.76
24
LO PR
MBh
S/T
Delta T
63
23
S/T
Delta T
22
S/T
Delta T
5.3
260
107
A MPS
HI PR
LO PR
4.17
0.74
0.83
MBh
KW
58.5
106
56.8
LO PR
5.4
114
280
5.4
4.25
20
113
277
5.3
258
HI PR
4.21
21
110
A MPS
4.14
0.71
0.79
MBh
KW
56.8
103
55.1
LO PR
5.3
269
5.2
250
HI PR
4.12
22
0.68
52.4
113
277
5.4
4.21
16
0.61
57.9
112
275
5.3
4.18
17
0.58
56.2
109
266
5.2
4.09
18
0.56
51.9
A MPS
4.05
106
HI PR
KW
5.3
258
A MPS
4.13
0.73
S/T
KW
105
55.9
MBh
HI PR
LO PR
5.2
255
A MPS
4.10
0.69
S/T
KW
102
54.2
MBh
HI PR
LO PR
5.1
247
A MPS
4.02
Delta T
KW
0.67
S/T
59
50.1
MBh
67
309
133
125
5.8
4.50
11
0.36
67.9
132
305
5.7
4.46
12
0.34
66.0
128
296
5.6
4.36
12
0.33
60.9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
296
5.6
4.37
16
0.56
63.3
124
293
5.5
4.34
17
0.53
61.5
120
284
5.4
4.24
18
0.51
56.7
124
293
5.5
4.34
12
0.42
63.4
122
290
5.5
4.30
13
0.40
61.6
119
281
5.4
4.21
13
0.39
56.8
59
114
292
5.7
4.46
22
0.86
55.5
112
289
5.6
4.42
23
0.82
53.9
109
281
5.5
4.33
24
0.79
49.7
112
289
5.6
4.42
19
0.75
54.6
111
286
5.6
4.39
20
0.72
53.0
108
278
5.5
4.29
21
0.69
48.9
63
67
132
332
6.0
4.68
16
0.58
61.8
131
329
5.9
4.65
17
0.55
60.0
127
319
5.8
4.54
18
0.53
55.4
131
329
5.9
4.64
12
0.44
62.0
129
325
5.9
4.61
13
0.42
60.1
125
316
5.7
4.51
14
0.40
55.5
140
346
6.2
4.82
11
0.37
66.4
139
343
6.1
4.79
12
0.36
64.4
135
332
6.0
4.68
13
0.34
59.5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
118
332
6.1
4.72
22
0.88
54.2
117
329
6.1
4.68
23
0.84
52.6
113
319
5.9
4.57
24
0.81
48.5
117
329
6.1
4.68
19
0.77
53.3
116
326
6.0
4.64
20
0.74
51.7
112
316
5.9
4.54
21
0.71
47.7
126
357
6.2
4.81
20
0.79
55.8
124
354
6.2
4.78
21
0.75
54.1
121
343
6.0
4.67
22
0.72
50.0
124
354
6.2
4.77
16
0.65
55.2
123
350
6.1
4.74
17
0.62
53.6
119
340
6.0
4.63
18
0.59
49.5
63
137
378
6.4
4.96
16
0.59
60.4
136
374
6.4
4.92
17
0.57
58.6
132
363
6.2
4.81
18
0.55
54.1
136
374
6.4
4.92
12
0.45
60.5
134
370
6.3
4.88
13
0.43
58.7
130
359
6.2
4.77
14
0.41
54.2
67
146
394
6.6
5.11
11
0.38
64.8
145
390
6.6
5.07
12
0.36
62.9
140
378
6.4
4.95
13
0.35
58.1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
124
378
6.5
4.94
22
0.91
52.8
123
375
6.4
4.91
23
0.86
51.3
119
363
6.3
4.79
24
0.83
47.3
123
375
6.4
4.91
19
0.80
52.0
122
371
6.4
4.87
20
0.76
50.4
118
360
6.2
4.76
21
0.73
46.6
59
132
407
6.6
5.05
20
0.81
54.4
131
403
6.6
5.01
21
0.77
52.8
127
391
6.4
4.89
22
0.75
48.8
131
403
6.6
5.01
16
0.67
53.9
129
399
6.5
4.97
17
0.64
52.3
125
387
6.3
4.85
18
0.61
48.3
63
67
144
430
6.8
5.20
17
0.61
58.9
143
426
6.7
5.16
18
0.59
57.2
138
413
6.6
5.04
18
0.56
52.8
143
426
6.7
5.16
13
0.46
59.0
141
421
6.7
5.12
13
0.44
57.3
137
409
6.5
5.00
14
0.42
52.9
Ente ring Indoor We t Bulb Te m pe rature
95
Outdoor Am bie nt Te m pe rature
85
NOTE: Shaded area is A CCA (TVA ) conditions
121
314
5.8
4.55
20
0.77
57.1
120
311
5.8
4.51
21
0.73
55.5
116
302
5.6
4.41
22
0.70
51.2
120
311
5.8
4.51
16
0.63
56.5
118
308
5.7
4.48
17
0.60
54.9
115
299
5.6
4.38
18
0.58
50.7
75
EXPANDED PERFORM ANCE DATA
High and low pressures are measured at the liquid and suction service valves.
* Entering Indoor Dry Bulb Temperature
2000
1750
1500
2000
1750
1500
Airflow
65
MODEL: GSX130604 A* / CA*F4961*6A*
153
448
7.0
5.36
11
0.39
63.2
152
444
7.0
5.32
12
0.38
61.4
147
431
6.8
5.19
13
0.36
56.6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
63
138
458
7.0
5.24
20
0.84
51.7
137
454
6.9
5.20
21
0.80
50.2
133
440
6.8
5.08
22
0.77
46.3
137
453
6.9
5.20
16
0.69
51.2
135
449
6.9
5.16
17
0.66
49.7
131
435
6.7
5.04
18
0.64
45.8
67
151
484
7.2
5.41
16
0.64
55.9
149
479
7.1
5.36
17
0.61
54.3
145
465
7.0
5.24
18
0.59
50.1
149
479
7.1
5.36
12
0.48
56.1
148
474
7.1
5.32
13
0.46
54.4
143
460
6.9
5.20
14
0.44
50.2
161
505
7.4
5.58
11
0.41
60.0
159
500
7.4
5.53
12
0.39
58.3
154
485
7.2
5.40
12
0.38
53.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
59
134
470
7.2
5.31
20
0.95
46.5
133
466
7.1
5.26
21
0.91
45.1
129
452
7.0
5.14
22
0.87
41.7
133
466
7.1
5.26
18
0.83
45.7
132
461
7.1
5.22
19
0.80
44.4
128
447
6.9
5.10
19
0.77
41.0
63
143
506
7.3
5.42
19
0.85
47.9
142
501
7.3
5.37
20
0.81
46.5
137
486
7.1
5.25
21
0.78
42.9
142
501
7.3
5.37
15
0.70
47.4
140
496
7.2
5.33
16
0.66
46.0
136
481
7.0
5.21
17
0.64
42.5
AMPS=outdoor unit amps (comp.+fan)
KW =Total system power
130
426
6.8
5.14
22
0.94
50.2
129
421
6.8
5.10
23
0.90
48.7
125
409
6.6
4.98
24
0.87
45.0
129
421
6.8
5.10
19
0.83
49.4
127
417
6.7
5.06
20
0.79
47.9
124
405
6.6
4.94
21
0.76
44.2
105
115
156
534
7.6
5.58
15
0.64
51.8
155
529
7.5
5.54
16
0.61
50.3
150
513
7.3
5.41
17
0.59
46.4
155
529
7.5
5.54
12
0.48
51.9
153
524
7.4
5.50
12
0.46
50.4
148
508
7.3
5.37
13
0.44
46.5
67
166
557
7.8
5.76
11
0.41
55.6
165
552
7.8
5.72
11
0.39
54.0
160
535
7.6
5.58
12
0.38
49.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
71
COOLING OPERATION
COOLING PERFORMANCE DATA
GSX130604A*
85
80
IDB*
272
253
104
56.1
0.86
25
HI PR
LO PR
MBh
S/T
Delta T
0.95
26
S/T
Delta T
5.4
266
110
AMPS
HI PR
LO PR
4.23
58.8
MBh
KW
109
117
286
5.5
4.31
25
0.92
60.0
116
283
263
HI PR
LO PR
27
4.28
5.5
27
Delta T
0.87
58.2
274
112
5.3
28
4.18
0.84
53.7
116
5.5
283
4.28
23
114
4.20
5.4
0.91
S/T
KW
AMPS
57.1
MBh
28
4.10
Delta T
KW
5.2
0.87
S/T
255
105
52.7
MBh
HI PR
LO PR
109
LO PR
AMPS
5.4
263
24
AMPS
HI PR
0.91
S/T
Delta T
4.20
0.85
57.8
MBh
KW
59.1
107
LO PR
280
260
HI PR
4.25
5.4
4.17
5.3
KW
AMPS
24
0.81
57.4
111
4.15
5.3
4.07
5.2
KW
AMPS
26
25
0.78
0.83
S/T
Delta T
63
52.9
59
51.8
MBh
67
127
302
5.7
4.43
24
0.83
62.8
126
299
4.40
5.6
25
0.79
61.0
290
122
5.5
26
4.30
0.76
56.3
126
5.6
299
4.40
20
0.69
63.1
125
296
4.37
5.6
21
0.66
61.3
121
287
4.27
5.4
22
0.64
56.6
71
136
315
5.8
4.56
21
0.67
67.0
134
312
4.53
5.8
22
0.64
65.0
302
130
5.7
23
4.43
0.62
60.0
134
5.8
312
4.53
16
0.52
67.5
133
309
4.50
5.8
17
0.49
65.5
129
299
4.40
5.6
18
0.48
60.5
59
116
298
5.8
4.52
26
0.99
57.5
115
295
4.49
5.7
28
0.94
55.8
286
111
5.6
29
4.39
0.91
51.5
115
5.7
295
4.49
24
0.94
56.5
114
292
4.46
5.7
26
0.90
54.8
110
283
4.36
5.5
27
0.86
50.6
63
123
321
5.9
4.61
26
0.95
58.6
122
318
4.58
5.8
27
0.91
56.9
308
118
5.7
28
4.48
0.87
52.5
122
5.8
318
4.58
23
0.88
57.7
121
314
4.55
5.8
25
0.84
56.0
117
305
4.44
5.7
26
0.81
51.7
75
67
135
339
6.1
4.75
24
0.86
61.3
133
335
4.72
6.0
26
0.82
59.6
325
129
5.9
27
4.61
0.79
55.0
133
6.0
335
4.72
20
0.72
61.6
132
332
4.68
6.0
22
0.68
59.9
128
322
4.57
5.8
22
0.66
55.2
71
143
353
6.3
4.90
21
0.70
65.4
142
350
4.86
6.2
22
0.66
63.5
339
138
6.1
23
4.75
0.64
58.6
142
6.2
350
4.86
16
0.54
65.9
140
346
4.82
6.2
17
0.51
64.0
136
336
4.71
6.0
18
0.49
59.1
59
120
339
6.2
4.79
26
1.00
56.1
119
336
4.75
6.2
28
0.96
54.5
325
116
6.0
29
4.64
0.93
50.3
119
6.2
336
4.75
24
0.96
55.1
118
332
4.72
6.1
26
0.92
53.5
114
322
4.61
6.0
27
0.89
49.4
128
365
6.3
4.89
26
0.97
57.2
127
361
4.85
6.3
27
0.93
55.5
350
123
6.1
28
4.74
0.90
51.2
127
6.3
361
4.85
23
0.90
56.3
126
358
4.81
6.2
25
0.86
54.7
122
347
4.70
6.1
26
0.83
50.5
402
149
140
6.7
5.19
21
0.71
63.9
147
398
5.15
6.7
22
0.68
62.0
386
143
6.5
23
5.03
0.66
57.2
147
6.7
398
5.15
16
0.55
64.3
146
394
5.11
6.6
17
0.52
62.5
142
382
4.99
6.5
18
0.51
57.6
385
6.5
5.03
24
0.88
59.9
138
381
4.99
6.5
26
0.84
58.1
370
134
6.3
27
4.88
0.81
53.7
138
6.5
381
4.99
20
0.74
60.2
137
378
4.96
6.4
22
0.70
58.4
133
366
4.84
6.3
22
0.68
53.9
126
386
6.6
5.02
25
1.00
54.7
125
382
4.98
6.5
28
0.99
53.1
371
121
6.4
29
4.87
0.96
49.0
125
6.5
382
4.98
25
1.00
53.8
124
378
4.94
6.5
26
0.95
52.2
120
367
4.83
6.3
27
0.91
48.2
135
415
6.7
5.12
26
1.00
55.8
133
411
5.08
6.7
27
0.96
54.2
399
129
6.5
28
4.97
0.93
50.0
133
6.7
411
5.08
24
0.93
55.0
132
407
5.05
6.6
25
0.89
53.4
128
395
4.93
6.4
26
0.86
49.2
Entering Indoor Wet Bulb Temperature
63
67
71
59
63
85
Outdoor Ambient Temperature
95
147
439
6.9
5.28
24
0.91
58.4
145
434
5.24
6.9
26
0.87
56.7
421
141
6.7
27
5.12
0.83
52.3
145
6.9
434
5.24
20
0.76
58.7
430
144
6.8
22
5.20
0.72
57.0
140
417
5.08
6.6
23
0.70
52.6
67
EXPANDED PERFORMANCE DATA
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction service valves.
2000
1750
1500
2000
1750
1500
Airflow
65
MODEL: GSX130604 A* / CA*F4961*6A*
71
156
458
7.1
5.45
21
0.74
62.3
155
453
5.40
7.1
22
0.70
60.5
439
150
6.9
23
5.28
0.68
55.8
155
7.1
453
5.40
16
0.57
62.8
153
448
5.36
7.0
17
0.54
60.9
149
435
5.24
6.9
18
0.52
56.2
59
63
141
467
7.1
5.33
24
1.00
53.0
140
463
5.29
7.0
27
1.00
51.4
449
135
6.9
28
5.16
0.96
47.5
140
7.0
463
5.29
23
0.97
52.2
138
458
5.24
7.0
25
0.92
50.7
134
444
5.12
6.8
26
0.89
46.8
67
154
493
7.3
5.49
24
0.94
55.5
152
489
5.45
7.2
25
0.90
53.9
474
148
7.1
26
5.32
0.87
49.7
152
7.2
489
5.45
20
0.79
55.8
151
484
5.41
7.2
21
0.75
54.2
146
469
5.28
7.0
22
0.72
50.0
71
164
515
7.6
5.67
21
0.76
59.2
162
510
5.62
7.5
22
0.73
57.5
494
157
7.3
23
5.49
0.70
53.1
162
7.5
510
5.62
16
0.59
59.6
161
505
5.58
7.4
17
0.56
57.9
156
489
5.44
7.2
18
0.54
53.4
59
137
480
7.3
5.39
22
1.00
48.2
136
475
5.35
7.3
25
1.00
46.7
461
132
7.1
26
5.22
1.00
43.1
136
7.3
475
5.35
22
1.00
47.3
134
470
5.31
7.2
24
0.99
45.9
130
456
5.18
7.0
25
0.96
42.4
63
146
516
7.5
5.50
23
1.00
49.1
144
511
5.46
7.4
25
1.00
47.7
496
140
7.2
26
5.33
0.97
44.0
144
7.4
511
5.46
22
1.00
48.4
143
506
5.42
7.3
23
0.93
46.9
139
491
5.29
7.2
24
0.90
43.3
AMPS=outdoor unit amps (comp.+fan)
KW=Total system power
133
434
6.9
5.22
24
1.00
52.0
131
430
5.18
6.9
27
1.00
50.5
417
127
6.7
28
5.06
1.00
46.6
131
6.9
430
5.18
23
1.00
51.1
130
426
5.14
6.8
26
0.98
49.6
126
413
5.02
6.7
27
0.95
45.8
105
115
159
545
7.7
5.67
22
0.95
51.4
158
540
5.63
7.6
24
0.91
49.9
524
153
7.4
25
5.50
0.87
46.1
158
7.6
540
5.63
19
0.79
51.7
156
534
5.59
7.6
20
0.76
50.2
151
518
5.45
7.4
21
0.73
46.3
67
COOLING OPERATION
71
170
569
8.0
5.86
19
0.77
54.8
168
563
5.81
7.9
21
0.74
53.2
546
163
7.7
21
5.67
0.71
49.1
168
7.9
563
5.81
15
0.59
55.2
166
557
5.76
7.8
16
0.57
53.6
161
541
5.62
7.6
17
0.55
49.5
COOLING PERFORMANCE DATA
GSX130604A*
51
PERFORMANCE DATA
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and
high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 2 degrees of the subcooling value shown in the installation
instructions.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 10 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 5 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
NOTE: Pressures are measures at the liquid and suction service valve ports.
52
L2
L1
1
SR
IO
CM
AUX
MAIN
ALTERNATE DOUBLE
POLE CONTACTOR
T2
T1
YL
2
5
BK
BL
BK
BR
PU
BK
YL
RD
CONTROL BOX
C
R
AUX
MAIN
COMP
S
HPS
BL/PK BL/PK
BL
T1
L1
C
L2
T2
BK
BK
BK
RCCF
YL
YL
BL
HERM
YL
F
SA
(IF USED)
NOTE 2
RD
BR
C
RD
RD
RD
YL
EQUIPMENT GROUND
USE COPPER
CONDUCTORS ONLY
RD
PU
RD
RD
SC
C
Y
NOTE 1
L1
C
T1
C
CM
IO
IO
MA
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
Y
IN
X
AU
SR
2
SC
C
(IF USED)
SA
RCCF
C
F
H
1
T2
C
0140R00116
USE N.E.C. CLASS 2 WIRE
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
HPS
C
X
S
AU
COMP
MA
IN
R
5
OUTDOOR POWER SUPPLY
SEE RATING PLATE
COMPONENT CODE
C --------------- CONTACTOR
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
IO -------------- INTERNAL OVERLOAD
LVJB ---------- LOW VOLTAGE JUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
HPS ----------- HIGH PRESSURE SWITCH
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
BL/PK ----------- BLUE/PINK STRIPE
BL
BL/PK
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
LVJB
L2
WIRING DIAGRAMS
GSX130[18-60]1A*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
53
L2
L1
1
IO
CM
AUX
MAIN
ALTERNATE DOUBLE
POLE CONTACTOR
T2
T1
YL
2
SR
BL
BK
BR
PU
BK
YL
RD
C
R
AUX
MAIN
COMP
S
YL
BL
L1
C
L2
YL
BL
HERM
YL
YL
F
YL
RCCF
SA
(IF USED)
NOTE 2
RD
BR
C
RD
RD
RD
EQUIPMENT GROUND
USE COPPER
CONDUCTORS ONLY
RD
PU
RD
T2
T1
RD
BK
BK BK
SC
Y
C
NOTE 1
L1
C
T1
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
COMPONENT CODE
C --------------- CONTACTOR
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
IO -------------- INTERNAL OVERLOAD
LVJB ---------- LOW VOLTAGE
JUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
S R ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
YL
BL
LVJB
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
54
5
BK
CONTROL BOX
C
Y
SR
2
C
F
SC
C
(IF USED)
SA
RCCF
H
1
T2
C
L2
0140R00015P
USE N.E.C. CLASS 2 WIRE
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
C
R
X S
AU
COMP
M
AI
N
X
AU
M
A
CM IN
IO
IO
5
OUTDOOR POWER SUPPLY
SEE RATING PLATE
WIRING DIAGRAMS
GSX130[18-60]1B*/GSX130181C*
VSX130[18-60]1A*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
WIRING DIAGRAMS
VSX130181B*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
OT--------------OUTDOOR THERMOSTAT
0140R00165-A
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
55
56
IO
CM
AUX
MAIN
BK
BR
PU
YL
YL
T1
BK
BL
CONTROLBOX
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
COMP
T2
L2
L1
T3
RD
L3
T3
T2
T1
C
YL
RD
BK
BK
PU
RD
RD
BR
EQUIPMENTGROUND
USECOPPER
CONDUCTORSONLY
FC
C
LVJB
NOTE1
L1
C
T1
CONTROLSSHOWNWITHTHERMOSTATIN'OFF'POSITION.
COMPONENTCODE
C---------------CONTACTOR
CM------------OUTDOORFANMOTOR
COMP--------COMPRESSOR
FC-------------FANCAPACITOR
IO--------------INTERNALOVERLOAD
LVJB ----------LOWVOLTAGE JUNCTIONBOX
FIELDWIRING
HIGHVOLTAGE
LOWVOLTAGE
WIRINGCODE
FACTORYWIRING
HIGHVOLTAGE
LOWVOLTAGE
OPTIONALHIGHVOLTAGE
COLORCODE
BK---------------BLACK
BL---------------BLUE
BR---------------BROWN
OR---------------ORANGE
PU---------------PURPLE
RD---------------RED
WH--------------WHITE
YL---------------YELLOW
Y
YL
BL
LVJB
C
IO
Y
T1
CM
IO
M
X
C
C
FC
L2
T3
C
0140R00160REV.B
USE N.E.C.CLASS2WIRE
NOTES:
1)TOINDOORUNITLOWVOLTAGE
TERMINALBLOCK &INDOOR
THERMOSTAT.
C
AI
N
AU
T3
COMP
T2
T2
OUTDOORPOWERSUPPLY
SEERATINGPLATE
L3
WIRING DIAGRAMS
GSX130[36-60][3,4]A*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.