Download Furuno SEARCHLIGHT CH-250 User's Manual
Transcript
Installation Manual SEARCHLIGHT SONAR CH-250 SAFETY INSTRUCTIONS....................... i 3. ADJUSTMENTS ............................... 31 3.1 General Checks..................................... 31 SYSTEM CONFIGURATION ................. iii 3.2 TX Frequency Checking........................ 32 EQUIPMENT LISTS .............................. iv 3.3 Heading Adjustment/Soundome Setting ......................................................... 34 1. Mounting ........................................... 1 1.1 Monitor Unit/Control Unit .........................1 1.2 Transceiver Unit .......................................6 1.3 Hull Unit ...................................................9 1.4 Interface Unit..........................................21 3.4 Adjustment of Motion Sensor ................ 37 3.5 System Back Up.................................... 38 3.6 Setting of Interface Unit......................... 40 Input/Output Description.................... 41 1.5 Motion Sensor MS-100 (option) .............22 2. Wiring .............................................. 23 PACKING LISTS ................................ A-1 2.1 Wiring among Units................................23 OUTLINE DRAWINGS ....................... D-1 2.2 Transceiver Unit .....................................26 2.3 Hull Unit .................................................29 INTERCONNECTION DIAGRAMS..... S-1 2.4 Interface Unit..........................................30 www.furuno.co.jp The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 All rights reserved. Printed in Japan A : MAR . 2000 K4 : SEP . 10, 2007 Pub. No. IME-13160-K4 (YOSH ) CH-250 *00080895011* *00080895011* * 0 0 0 8 0 8 9 5 0 1 1 * SAFETY INSTRUCTIONS WARNING WARNING Installe the specified transducer tank in accordance with the installation instructions. If a different tank is to be installed the shipyard is solely responsible for its installation, and it should be installed so the tank doesn't strike an object. ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Turn off the power at the switchboard before beginning the installation. The tank or hull may be damaged if the tank strikes an object. Fire or electrical shock can result if the power is left on. If a steel tank is installed on a wooden or FRP vessel, take appropriate measures to prevent electrolytic corrosion. Do not install the equipment where it may get wet from rain or water splash. Electrolytic corrosion can damage the hull. Water in the equipment can result in fire, electrical shock or equipment damage. Be sure that the power supply is compatible with the voltage rating of the equipment. Be sure no water leaks in at the transducer installation site. Connection of an incorrect power supply can cause fire or equipment damage. The voltage rating of the equipment appears on the label above the power connector. Water leakage can sink the vessel. Also confirm that the transducer will not loosen by ship's vibration. The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation. i CAUTION CAUTION Ground the equipment to prevent electrical shock and mutual interference. WORKING WITH THE SONAROIL Precautions Keep oil away from eyes. Wear protective gloves when working with the oil. The oil can cause inflammation of the eyes. Observe the following compass safe distances to prevent deviation of a magnetic compass: Standard Monitor unit/ Control unit 0.80 m Transceiver unit 0.50 m Interface unit 0.95 m Do not touch the oil. Wear protective gloves when working with the oil. The oil can cause inflammation of the skin. Steering 0.55 m Do not ingest the oil. Diarrhea or vomiting can result. 0.35 m Keep the oil out of reach of children. 0.65 m Emergency If the oil enters eyes, flush with clean water about 15 min. Consult a physician. Install the monitor unit MU-100C out of direct sunlight. If the oil contacts skin, wash within soap and water. It is difficult to see the display in direct sunlight. If the oil is ingested, see a physician immediately. Turn the main power off before this check, otherwise the raise/lower motor action may cause injurely Disposal of oil and its container Dispose of oil and its container in accordance with local regulations. For further details, contact place of purchase. Storage Seal container to keep out foreign material. Store in dark place. ii SYSTEM CONFIGURATION INTERFACE UNIT IF-8000 Note 2 MONITOR UNIT MU-100C Navigator Control Unit Display Unit Note 1 VGA Ext. Monitor Remote Controller Note 2 TRANSCEIVER UNIT CH-253 CONTROL UNIT CH-252 MOTION SENSOR 12-32 VDC HULL UNIT SPEAKER DATA/VIDEO OUT 12-32 VDC Speaker HULL UNIT CH-254/255 Motion Sensor 12/24-32 VDC Note 1: MU-100C is the standard supply display unit. An external monitor may be connected via the interface unit (option). The drawing above shows the system configuration with the MU-100C. Note 2: For blackbox type, MU-100C is not supplied. Connect external monitor (user supply) and control unit to the interface unit. iii EQUIPMENT LISTS Standard Supply Name Control Unit/ Monitor Unit Control Unit Interface Unit Transceiver Unit Hull Unit Spare Parts Type CH-252/ MU-100C CH-252 IF-8000 CH-253 CH-254 Code no. Remarks 1 Not supplied with blackbox type 1 1 1 Not supplied with unibody type For blackbox type See the following table for Hull Unit 250 stroke Standard Supply. For unibody type, SP06-01102*, SP06-01103* For blackbox type, SP06-01102*, SP06-01111*, SP06-01103* For unibody type CP06-01251* and two cables (page viii) For unibody type, FP02-05101*, FP06-01102* For blackbox type Hard cover For blackbox type 400 stroke 1 CH-255 SP06-01100 000-068-488 SP06-01110 000-068-489 SP06-01101* 006-556-200 1 Installation Materials Accessories Qty 1 FP02-05100 000-012-474 FP06-01120* 006-556-260 06-021-2121 100-320-101 1 1 *: See the lists at the back of this manual. iv Hull Unit (1) Code no. Type 000-068-515 000-068-516 000-068-517 000-068-518 000-068-519 000-068-559 000-068-560 000-068-561 000-068-562 000-068-563 000-068-520 000-068-521 000-068-522 000-068-523 000-068-524 000-068-525 000-068-526 000-068-527 000-068-528 000-068-529 000-068-564 000-068-565 000-068-566 000-068-567 000-068-568 000-068-530 000-068-531 000-068-532 000-068-533 000-068-534 000-068-535 000-068-536 000-068-537 000-068-538 000-068-539 000-068-540 000-068-543 000-068-544 000-068-547 000-068-548 000-068-569 000-068-570 000-068-571 000-068-572 000-068-573 000-068-549 000-068-550 000-068-551 000-068-552 000-068-553 000-068-554 000-068-555 000-068-556 000-068-557 000-068-558 000-068-574 000-068-575 000-068-576 000-068-577 000-068-578 CH-254-1-60-22-35 CH-254-1-88-22-35 CH-254-1-150-22-35 CH-254-1-180-22-35 CH-254-1-240-22-35 CH-254-1-60-22-52 CH-254-1-88-22-52 CH-254-1-150-22-52 CH-254S-1-180-22-52 CH-254S-1-240-22-52 CH-254-1-60-38-52 CH-254-1-88-38-52 CH-254-1-150-38-52 CH-254S-1-180-38-52 CH-254S-1-240-38-52 CH-254-2-60-22-35 CH-254-2-88-22-35 CH-254-2-150-22-35 CH-254S-2-180-22-35 CH-254S-2-240-22-35 CH-254-2-60-22-52 CH-254-2-88-22-52 CH-254-2-150-22-52 CH-254S2-180-22-52 CH-254S-2-240-22-52 CH-254-2-60-38-52 CH-254-2-88-38-52 CH-254-2-150-38-52 CH-254S-2-180-38-52 CH-254S-2-240-38-52 CH-255-1-60-22-35 CH-255-1-88-22-35 CH-255-1-150-22-35 CH-255S-1-180-22-35 CH-255S-1-240-22-35 CH-255-1-60-38-52 CH-255-1-88-38-52 CH-255-1-150-38-52 CH-255S-1-180-38-52 CH-255S-1-240-38-52 CH-255-1-60-22-52 CH-255-1-88-22-52 CH-255-1-150-22-52 CH-255S-1-180-22-52 CH-255S-1-240-22-52 CH-255-2-60-22-35 CH-255-2-88-22-35 CH-255-2-150-22-35 CH-255S-2-180-22-35 CH-255S-2-240-22-35 CH-255-2-60-38-52 CH-255-2-88-38-52 CH-255-2-150-38-52 CH-255S-2-180-38-52 CH-255S-2-240-38-52 CH-255-2-60-22-52 CH-255-2-88-22-52 CH-255-2-150-22-52 CH-255S-2-180-22-52 CH-255S-2-240-22-52 Spec. Stroke 400 mm Power 12 V 24 V-32 V 250 mm 12 V 24 V-32 V v Frequency 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz 60 kHz 88 kHz 150 kHz 180 kHz 240 kHz Shaft 2.2 m Cable 3.5 m 2.2 m 5.2 m 3.8 m 5.2 m 2.2 m 3.5 m 2.2 m 5.2 m 3.8 m 5.2 m 2.2 m 3.5 m 3.8 m 5.2 m 2.2 m 5.2 m 2.2 m 3.5 m 3.8 m 5.2 m 2.2 m 5.2 m Hull Unit Standard Supply Name Raise/lower Drive Unit Soundome Type CH-2541 CH-2551 CH-2542 Code no. - Flange Assembly Kit for field CH-2543 CH-2544 006-557-810 006-557-820 1 set 1 set Shaft SHJ-0006-1 06-007-1572-0 4 lit. 661-000-061 600-715-720 000-824-033 1 Sonar Oil vi Qty 1 set 1 set 1 Remarks See the following Soudome table. Flange, grease cotton Shaft, retraction tank, seal, adhesives, tank guide, material box 2.2 m, for 3.5/5.2 m cable 3.8 m, for 5.2m cable Shaft parts Name Pipe cap Jubilee Clip Hex. bolt U-nut Flat washer Type SHN-0011-0 1X28-41 M10X35 SUS304 M10 SUS304 M10 SUS304 Code no. 661-400-110 000-801-857 000-862-175 000-863-930 000-864-131 Qty 1 1 2 2 4 Remarks Type M20X80 SUS304 M20 SUS304 M20 SUS304 M20 SUS304 Code no. 000-801-893 000-863-116 000-864-136 000-864-270 Qty 8 16 16 8 Remarks Code no. 000-801-328 000-854-104 000-856-520 Qty 1 1 1 Remarks Anti-corrosion Sealant, 200g adhesive Code no. 006-557-200 Qty 1 Remarks Tank parts Name Hex. bolt Hex. nut Flat washer Spring washer Adhesives Name Kinolastar Three Bond Cemedine High Super Type 855 1104 6G Tank guide Name Tank guide Type CH-2544 Assembly kit for field (Material Box) Name Socket set screw Shim (0.5) Shim (1.0) Shim (2.0) Type TWB-40 06-021-4035 06-021-4036 06-021-4037 Code no. 000-804-423 100-295-420 100-295-430 100-295-440 vii Qty 1 2 2 4 Remarks 4 mm 0.5 mm 1.0 mm 2.0 mm Cables for Installation materials Type CP06-01200 CP06-01201 CP06-01202 CP06-01203 CP06-01204 CP06-01205 Code no. 000-068-496 000-068-497 000-068-498 000-068-499 000-068-500 000-068-502 Specification (Cable between unit) Monitor unit (or IF) Transceiver unit and Hull unit and Transceiver unit 06S4078*5m* 06S4080*15m* 06S4080*30m* 06S4080*50m* 06S4078*10m* 06S4080*15m* 06S4080*30m* 06S4080*50m* Crimp-on lug CP06-01251* CP06-01251* CP06-01251* CP06-01251* CP06-01251* CP06-01251* Control unit cable Type Code no. Qty Remarks CP02-06600* 000-012-486 1 MJ-A10SPF0002-0015, for unibody type CP02-06610* 000-012-480 1 MJ-A10SPF0002-015, 1.5 m CP02-06620* 000-012-481 For blackbox type MJ-A10SPF0002-050, 5 m *: See lists at the back of this manual. Options Name Remote Controller Interface Unit Motion Sensor Speaker Signal Cable Cable assy. Control Unit Separate Kit Flush mount kit Control unit flush mount kit Rectifier Tank Type CH-256-E IF-8000 MS-100 SC-05WR S06-9-5 MJ-A6SSPF0012-050 MJ-A6SSPF0012-100 MJ-A6SSPF0011-050 MJ-A6SSPF0011-100 OP06-15-1.5 NEW OP06-15-5 NEW OP02-83-1.5 OP02-83-5 OP06-16 OP06-17 OP06-18 Code no. 000-068-492 000-068-495 000-136-156 006-556-270 000-134-424 000-133-817 000-132-244 000-132-336 006-559-140 006-559-150 001-413-600 001-413-610 006-556-300 006-556-310 006-556-320 1 1 1 1 1 RU-1746B-2 06-007-1570-1 SHJ-0001-1 06-007-1571-1 06-021-4024-0 06-007-1573-0 OP10-5 000-030-439 600-715-701 661-000-011 600-715-711 100-295-470 600-715-730 000-069-763 1 1 1 1 1 1 1 viii Qty 1 set 1 set 1 set 1 1 1 1 Remarks Extension cable for speaker 6pin-6pin, 5m 6pin-6pin, 10m 6pin-4pin, 5m 6pin-4pin, 10m For desktop, with 1.5 m For desktop, with 5 m For flush mount, with 1.5 m cable For flush mount, with 5m cable For unibody type For separate type display unit Steel, 1m Steel, 1.8m Steel, 3.5m FRP, 1m FRP, 1.8m Aluminum, 1m 1. Mounting NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 1.1 Monitor Unit/Control Unit This searchlight sonar has two types of shipment, standard type which is shipped with monitor unit and blackbox type which is shipped without monitor unit, but has interface unit. For blackbox type, see page 4. The control unit can be installed together with the monitor unit, or independently of the monitor unit. On installing separately, the optional monitor kit is required. These units can be installed on a tabletop or flush mounted in a console or panel. 1.1.1 • • General mounting considerations Keep the monitor unit out of direct sunlight. Select a location where the unit(s) can easily be operated while observing the fishing ground or area surrounding the vessel. • For maintenance and checking purposes, leave sufficient space at the sides and rear of the unit and leave slack in cable. (Refer to the outline drawing at the back of this manual.) • A magnetic compass will be affected if place too close to the monitor unit. Observe the following compass safe distance to prevent deviation to a magnetic compass: Standard compass: 0.80 m, Steering compass: 0.55 m. 1.1.2 Mounting method of monitor unit (Standard type) 1. Fasten the mounting base to the mounting location with four tapping screws. FRONT Mounting base 1 2. For unibody mounting; a) Fasten the bracket at the rear of monitor and control units with four binding screws (M4x10). 1 Bracket (rear view) 1 2 2 3 3 4 4 Bracket, rear view 3. For separate/blackbox mounting; a) Dismount the coupling plate to separate monitor unit and control unit. b) Attach the bracket at rear of the monitor unit with four binding screws (M4x10). Bracket (rear view) 1 1 3 2 2 4 3 4 Bracket, rear view 4. Coat threads of upset screws (M6x16, 2 pcs.) used to fasten bracket to mounting base. 5. Fasten the bracket to the mounting base with two upset screws. (Use the upper holes to tilt the monitor unit 20°; lower holes to tilt it 9°.) MOUNTING BASE HANGER Upset Screw Fastening hanger to mounting base 2 Flush mounting Flush mounting for unibody (Type: OP06-16, Code no.: 006-556-300) Name Type Code No. Qty Fixing metal 06-021-1311-2 100-279-612-10 1 Self-tapping screw 5x20 000-162-609-10 6 Hex. bolt M4x12 000-162-939-10 4 Remarks 1. Make holes at the place to mount (W287 x H297). 2. Fasten monitor and control units with the fixing metal (supplied as option) and four hex. bolts (supplied as option). 3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with six tapping screws (supplied as option). Hex. Bolts Fixing metal Flush mounting for monitor unit (Type: OP06-17, Code no. 006-556-310) Name Type Code No. Qty Fixing metal 06-021-1321-2 100-279-622-10 1 Self-tapping screw 5x20 000-162-609-10 4 Hex. bolt M4x12 000-162-939-10 4 Remarks 1. Make holes at the place to mount (W287 x H207). 2. Fasten the fixing metal (supplied as option) to the monitor unit with four hex. bolts (M4x12, supplied as option). 3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping screws (5x20, supplied as option). 3 Hex. Bolts Fixing Metal Flush mounting for control unit Type: OP02-83-1.5, Code no.: 001-413-600 (1.5 m cable) OP03-83-5, Code no.: 001-413-610 (5m cable) Name Type Code No. Qty Remarks Fixing metal 06-021-2101-2 100-279-732-10 1 Self-tapping screw 5x20 000-162-609-10 4 Hex. bolt M4x12 000-162-939-10 2 Cable assembly MJ-A10SPF0002-0 15 000-142-878 1 1.5 m MJ-A10SPF0002-0 50 000-131-411 1 5m Select one. 1. Make holes at the place to mount (W287 x H87). 2. Fasten the fixing metal to the control unit with two hex. bolts (supplied as option). 3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping screws (supplied as option). Hex. Bolts Fixing metal 1.1.3 Blackbox type The blackbox type is required to connect a standard VGA monitor via the interface unit IF-8000. Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male, three rows of 15 pins) locally. The monitor used should satisfy the specifications shown below. • • • VGA type ANALOG RGB 0.7 Vpp, positive polarity TLL level H, V, Negative polarity 4 1.1.4 Control unit On blackbox type, fix the control unit to the mounting plate (supplied as accessories). See the parts list of FP06-01120 and outline drawings at the back of this manual. 1. Fix the mounting plate to the place selected with two tapping screws (5x20, supplied). 2. Fix the bracket to the control unit with two hex. screws (M4x12, supplied). 3. Insert the screw driver from the top of the mounting plate holes and then tighten two hex. screws (M4x12) loosely. 4. Attach the control unit to the mounting plate, and fasten two hex. screws tightly. 5. Attach two cosmetic caps to holes at the top of the mounting plate. Mounting plate Cable entrance hole Cable Fasten the screws to fix the bracket. Tapping screws (5x20) Insert to the hex. screws tightened at step 3. Bracket Bracket Cable can be passed this direction. 6. Attach hard cover to protect the control unit. How to remove the hard cover Place your thumbs at the locations shown with circles in the illustration at right, and then lift the cover while pressing it with your thumbs. On mounting the control unit separate from the monitor unit, the optional control unit separate kit is required. Mount the control unit same as the above procedure. See the outline drawing at the back of this manual to mount. Type: OP06-15-1.5 NEW Code no.: 006-559-140: with 1.5 m cable Type: OP06-15-5 NEW Code no.: 006-559-150: with 5 m cable Name Cable Type Code no. Qty MJ-A10SPF0002-015 000-142-878 MJ-A10SPF0002-050 000-131-411 Bracket 06-021-2112 100-281-880-10 1 Mounting Plate 06-021-2111-1 100-279-741-10 1 Tapping Screw 5x20 000-162-608-10 2 Cosmetic Cap DP-687 000-165-997-10 2 Hex. Screw M4x12 000-162-939-10 4 Bind Screw M4x10 000-807-331 4 5 1 Remarks For 1.5 m cable For 5 m cable For monitor 1.2 Transceiver Unit 1.2.1 General mounting considerations • • • The mounting location should be well ventilated and dry. The unit can be mounted on bulkhead or the deck. Secure the maintenance space shown in drawing below for ease of maintenance and service. • The maximum cable length between the transceiver unit and the raise/lower drive unit cable is 50 m. • The maximum cable length between the transceiver unit and the monitor (interface) unit is 10 m. 1.2.3 Mounting method Fasten the transceiver unit with four tapping screws (5X20, local supplied). For bulkhead mounting, tighten upper tapping screws so there is 5 mm clearance between bottom of screw head and bulkhead, and screw slots of the unit. Then fasten lower screws. 1.3 Hull Unit 1.3.1 General mounting considerations • • Noise and air bubbles will affect performance. Do not turn on the equipment with the transducer exposed to air. Exposing the transducer to air may damage it. 1.3.2 Installation position considerations Discussion and agreement are required with the dockyard and ship owner in deciding the location for the hull unit. When deciding the location, take into account the following points: • Select an area where propeller noise, cruising noise, bubbles and interference from turbulence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s length from the bow or near the keel is the best. On-the-keel installation is advantageous for minimizing oil consumption in comparison with of-the-keel. If the hull unit cannot be installed on the keel, the center of the retraction tank should be within 1 meter of the keel to prevent a rolling effect. 6 1/3 1/2 Within 1 meter Installation location for hull unit • Select a place where interference from the transducers of other sounding equipment is minimal. The hull unit should be at least 2.5 meters away from the transducers of other sounding equipment. • An obstacle in the fore direction not only causes a shadow zone but also aerated water, resulting in poor sonar performance. Be sure to locate the transducer well away from any obstacle in the fore direction. Mounting method A typical mounting method is shown in the outline drawing at the back of this manual. Consult ship’s owner, dockyard and user to determine appropriate mounting method. Pay attention to safety (strength, watertightness) first, followed by ease of maintenance and inspection. 1.3.3 Transducer tank Tank length Shorten the transducer tank so the transducer is Wealding bead lowered into water as deep as possible. Pay particular attention to the tank length Lt. Determine the length of the main shaft. • • Length of main shaft = Lt + 200 mm (for 400 stroke) Length of main shaft = Lt + 50 mm (for 250 stroke) Note : When the retraction tank is constructed locally, finish it so that welding beads do not protrude on the inner surface of the tank. The tank guide will hit the bead, burning out the raise/lower motor. Also, do not position the welding bead in the ship’s fore-aft line. 7 Wealding bead For small FRP ship For small FRP ship retraction tank should be 2 degrees against ship’s draft. Therefore, this creates high water pressure in the tank because of the resistance at the rear of the tank well. To solve this problem, attach a fin to the hull at the location shown in figure below. Retraction dome Bottom of ship Fin This fin makes a smooth stream in the retraction dome. Attach the fin (height:1-1.5 cm, FRP). Mounting of transducer tank Install the transducer tank referring to the hull unit outline drawings at the back of this manual. Note 1: When making a retraction tank locally, the inside diameter of the retraction tank should not be more than φ190±0.5 as shown on outdrawing at the back of this manual. If larger, the hull unit may be danger. Note 2: Locate the retraction tank so that the center of any two bolt holes is facing the ship’s bow. a=b a b 8 Bow 1.3.4 Assembling and mounting of hull unit The hull unit is shipped as the parts shown in the hull unit kit on Equipment Lists (page iv and after). Assemble the hull unit as shown in the procedure below. Necessary tools Name Specification Remarks Wrench For M10 (Hex. size 17 mm) Wrench For M20 (Hex. size 20 mm) Pipe Wrench 55 mm For fixing gland Ball Wrench Hex size 4 mm For fixing the dome Recommended: double offset wrench 1. Calculate necessary length of main shaft from the length of retraction tank Lt and cut off the spare portion. When 1 m or 1.8 m long tank is used, main shaft (1.17 m or 1.97 m) can be used without cutting off any portion. Supplied length: 2.2 m or 3.8 m Lt + 200 mm for 400 mm stroke Lt + 50 mm for 250 mm stroke Chamfer the edge to protect O-ring from damage. Take care not to damage. 2. Remove hex bolt, nut, spring washers, flat washers and trunnion pins from the main body flange. And then, mount the raise/lower drive unit on the shaft sleeve by using the hardware removed. 9 ING RN WA WA RN ING Raise/lower section Flat Nut washer Hex. bolt (M10X30) Shaft sleeve Spring washer Flat washer Trunnion pin Shaft sleeve and raise/lower drive unit assembly 3. Pass the transducer cable through the main shaft. 10 4. Fully screw main shaft into the soundome neck, and then unscrew by four turns. Coat threads with adhesive (HIGH SUPER). Main Shaft Grasp the soundome neck with a wrench, and tighten the shaft with a pipe wrench. Coat threads with adhesive (HIGH SUPER). Applying Adhesive (HIGH SUPER) to main shaft 5. Screw in main shaft completely. 6. As shown in the drawing below, confirm that the narrowest gap between the tank guide, and retraction tank in the range (20 to 170 mm) is within 0.5 mm. Slide range (Stroke) 250 or 400 Retraction tank 20 mm (400 stroke) 170 mm (250 stroke) Tank guide less than 0.5mm Tank and tank guide, sectional view 11 7. If the gap at a side is more than 0.5 mm, install a shim to make the gap within 0.5 mm. a) Unscrew four M10x50 bolts. b) Unscrew four countersunk screws, then attach the shim with the countersunk screws as shown below. Nut Flat washer Countersunk screw (M4x16) Hex. bolt (M10x70) Guide plate Shim (1.0) Flat washer Shim (1.5) Spring washer Hex. bolt (M10X50) Installing shims 12 The table below shows tank length and necessary shim thickness. In addition, the shim thickness shown is for one side. For example, when cutting the 1800 mm tank to 800 mm, the 1800 8 1600 7 1400 6 1200 5 1000 4 800 3 600 400 2 200 1 0 0 194 189 190 191 192 193 Tank inside dia. Φ B (mm) Shim thickness (mm) Length A (mm) tank shortened tank inside diameter is 191.25 mm, shim thickness is 2.5 mm as shown the table in below. For 1 m tank For 1.8 m tank Shim thickness The table below shows number of shims required and shim thickness. Shim thickness 0 t2.0 t1.0 t0.5 Inside dia of tank 188.1 0.5 1 188.7 1 1.5 1 1 1 189.9 189.3 2 1 2.5 1 190.5 1 191.1 13 3 1 1 191.7 3.5 1 1 1 192.3 4 2 4.5 2 192.9 1 193.5 5 2 1 194.1 5.5 2 1 1 194.7 6 2 2 195.3 6.5 2 2 1 195.9 8. Apply THREE BOND 1104 to the inside of tank guide. And then, fasten tank guide at the neck* of the main shaft securely with M10X80 bolts. Hex. Bolt (M10X80) : coated with THREE BOND 1104 Flat washer Spring Washer Nut * Bow Mark Bow Face the tank guide toward ship's bow. Tank guide attachment 9. Pass the main shaft through shaft sleeve. 10. Pass the main shaft through the shaft retainer at the raise/lower drive unit. Pipe cap U-nut Shaft retainer Spring washer Hex. bolt M10X35 Bow mark Main body flange 14 11. Face the bow mark on the soundome with the bow mark on the shaft sleeve, and then fix the main shaft with and shaft retainer. 12. Fix the jubilee clip to the main shaft. Hex. bolt Shaft retainer 15 mm 1-2 mm Jubilee Clip Main shaft Note: Attach the shaft retainer so it is 15 mm from the top of the shaft. The soundome is then placed 10 mm above the bottom of tank when retracted. 13. Insert grease cotton (supplied with shaft sleeve), and fix them with the cotton retainer as follows. a) Wind grease cotton onto main shaft. b) Mark on the cotton as below. c) Remove the cotton from the shaft, and then cut it at the position of the mark. Discard the ends. d) Wind cottons as shown below. e) Push cottons into the main body flange. f) Tighten the grease cotton retainer. Wind grease cotton onto main shaft and cut it as shown below. Space joints of grease cotton 120 apart and push them into body flange. Spring washer Cotton retainer Installing grease cotton on the main shaft 14. Fasten the pipe cap (supplied) to main shaft. 15. Unscrew 10 pcs of M5X35 socket head cap screws with soundome fixing tool to separate soundome. 15 Rotate 4 or 5 turns by hand to make sure that turning mechanisms are functioning properly. Socket head cap screw 10pcs, M5x30 Spring washer O-ring Remove. Apply KINORUSTER. Soundome Protection sponge Detaching the soundome 16. Throw away protection sponge placed in soundome. 17. Stand the soundome upright on top of the soundome packing. Fill the soundome with oil (supplied) so the level is 5 cm on the top of the soudome. Keep the soundome packing for future use. Ball wrench Sonar oil 5 cm Stand the soundome upright on top the soundome packing. Filling the soundome with sonar oil 16 CAUTION Keep oil away from eyes. Where protective goggles when working with the oil. The oil cause inflammation of the eyes. Do not touch the oil. The oil can cause inflammation of the skin. Wear protective gloves when working with the oil. Do not ingest the oil. Diarrhea or vomiting can result. Keep the oil out of reach of children. EMERGENCY If the oil enters the eyes, flush with clean water about 15 minutes. Consult a physician. If oil contacts skin, wash with soap and water. If the oil is ingested, see a physician immediately. DISPOSAL OF OIL AND ITS CONTAINER Dispose of oil and its container in accordance with local regulations. For further information,contact place of purchase. STORAGE Seal container to keep out foreign material. Store in dark place. 18. Rotate the transducer manually as shown angle in below, and then refit soudome. Transducer Soundome . Note 1: Do not lay the oil-filled soundome for five minutes. Oil may leak. 17 When the soundome is painted to keep marine life off the transducer, observe the following precautions: • Use only anti-fouling paint type MARINE STAR 20 (Manufacture: Chugoku Marine Paint Co., Ltd., Japan). • Paint only the plastic portion of the dome. Painting the metal parts causes corrosion. Paint area 19. Clean surface of gasket, tank flange and shaft sleeve, and then apply THREE BOND 1104 to flange gasket. 20. Apply a slight coat of KINORUSTER to bolts, nuts and washers. 21. Set the hull unit into the retraction tank, taking care not to damage soundome. U-nut Shaft retainer Spring washer Hex. bolt M10X35 Nut Spring washer Flat washer Bow mark Shaft sleeve Flange gasket Retraction tank flange Flat washer Hex. bolt M20X80 18 22. Fix the shaft sleeve and retraction tank with hex bolts, flat washers and spring washers. Hex bolt Shaft retainer 15 mm 1-2 mm Jubilee clip Main shaft Bow 10 mm 19 Checking manual raise/lower of soundome with hand crank Perform this check after all wiring has been completed. CAUTION Turn the main power off before this check, otherwise the raise/lower motor action may cause injurely. 1. Turn off the breaker on the hull unit. 2. Detach the gear cover. 3. Set wrench (opposite side19 mm) to the screw shaft gear. 4. The transducer should rise/lower smoothly with even force in upper to lower limits. If not, the centers of the shaft sleeve and the retraction tank are not aligned. Adjust the hull mounting position if necessary. Check the following points. • • • Painting inside tank not smooth Inner diameter of tank not uniform Welding bead 20 1.4 Interface Unit For the blackbox type, the interface unit is shipped as standard. 1.4.1 • • • • General mounting considerations The mounting location should be well ventilated and dry, avoiding splay or rain. The unit can be mounted on a bulkhead or the deck. Secure the maintenance space shown in drawing below for ease of maintenance and service. The maximum cable length between the interface unit and the transceiver unit is 10 m. External monitor Transceiver 06S4078 unit A 06S4078 Interface unit B External monitor Transceiver 06S4078 Interface unit unit A+B<=15m External monitor 06S4078 A 1.4.2 Monitor unit MU-100C Interface unit A+C<=15m C Mounting method Fasten the interface unit with four tapping screws (5X20, local supplied). For bulkhead mounting, tighten upper tapping screws so there is 5 mm clearance between bottom of screw head and bulkhead, and screw slots of the unit. Then fasten lower screws. 21 1.5 Motion Sensor MS-100 (option) The MS-100 measures ship’s pitching and rolling angles with sensor using the principles of the gyroscope. The MS-100 is free from error caused by ship’s vertical and horizontal motion. Therefore, it can be installed at any convenient location. However, ship’s semi-permanent inclination due to loading imbalance cannot be detected. Compensate for this as described in Chapter 3. 1.5.1 • • • Mounting considerations Vibration in the mounting area should be minimal. Locate the unit away from areas subject to water splash. The ambient temperature should not exceed 50 °C 1.5.2 Mounting procedure Orient the FORE mark on the unit toward the ship’s bow and mount the unit level to within 5° in all direction. For the offset, see Chapter 3. FORE θ ≤ 5° AFT 22 2. Wiring 2.1 • • • Wiring among Units The figure on the next page shows wiring among units. The signal cables are fitted with connectors. Connect the cables to the display, transceiver and hull units referring to the interconnection diagram and the drawing on page S-1. The power cable should be arranged locally. Use power cable type DPYCYS-2.5 (Japan Industrial Standard cable) or equivalent cables. Attach climp on lugs as shown below. 40 5 Vinyl sheath Braided shield Armor FV2-4(blue) 50 Conductor Insulator Inclusion Tape Braided shield Sheath Armor Vinyl sheath S = 2.5 mm 2 =15.2 mm • • The raise/lower drive motor and breaker are different depending on ship’s mains. Install the main switch for the sonar where it can be easily accessed. Turn off this switch when the sonar is not being used, to reduce power consumption and to prevent the transducer from slipping by vibration. • If D-sub connector is too large to pass through the hole on the monitor, transducer and/or interface unit, remove the connector cover. 23 Navigation Equipment Note1 (5m) 06S4078 (5/10m) *a Interface Unit *b HULL UNT SPEAKER Speaker (w/cable) Remote Controler MONITOR Note 2 12-32VDC DATA/VIDEO OUT MOTION SENSOR 06S4037 (10m) 250V-DPYCYS-2.5 12-32VDC Ext. KP Motion Sensor 06S4080(15/30/50m) 06S4081 (3.5/5.2m) 12/24-32VDC 250V-DPYCYS-2.5 Note1: Cable between the monitor unit and control unit 06S4079 (0.15m standard, for uni body type) 06S4085 (1.5m option, for separate type) 64S4063 (5m option, for separate type) Note2: A VGA monitor (local supply) can be added by the connecting the optional interface unit. Note3: < 15m *: a+b = Wiring, with monitor 24 Interface unit Note 1 Navigation Eauipment 15m *a *b 06S4078 (5/10m) 06S4078 (5/10m) External monitor Note 2 Interface unit External monitor 64S4063(5m) CONT REM Control unit, back view (5m) HULL UNT SPEAKER Speaker (w/cable) Remote Controler 12-32VDC DATA/VIDEO OUT Transceiver unit MOTION SENSOR 06S4037 (10m) Ext. KP Motion senser DPYCYS-2.5 12-32VDC 06S4080(15/30/50m) 06S4081 (3.5/5.2m) 12/24-32VDC DPYCYS-2.5 Note1: Two interface units are connectable. Note2: For blackbox type, the display monitor (local supply) is reqired. Note3: *a+b < =15m Wiring, no monitor 25 Hull unit 2.2 Transceiver Unit Connect the cables as figure in below. Remove the cover of the power terminal board. 06P0240 J3 NH6P CR12 J6 J1 + - J2 06P0241 *Note SPEAKER External speaker SC-05WR TRX DATA/VIDEO OUT Earth Monitor unit MOTION SENSOR Motion sensor MS-100 MU-100C or 06S4080 Interface unit Hull unit External KP IF-8000 CH-254/CH-255 *Note: Fix the braided shield with the clamp. Transceiver unit, internal view 26 To ship's earth 06P0242 TB1 *Note 12-32VDC DPYCYS-2.5 Ship's mains 12/24/32 DCV 2.2.1 Synchronizing Transmission with Echo Sounder or Other Sonar To synchronize transmission of the CH-250 with an echo sounder or other type of sonar, connect it as shown below. NH6P (local supply) Transceiver unit Vinyl wire (local supply) AWG22-26 J3 06P0240 Sonar, E/S 3 to 15V possitive KP OUT +5V to 15V GND KPI 3 EXT_SW 5 GND 6 TRX clamp Connection of transceiver unit to other sonar Menu setting 1. Press the [MENU] key to display the user menu. 2. Operate the cursor pad to select COM1 at the top of menu display. MENU TX POWER PULSELENGTH TX RATE INT REJECT AGC AUDIO LEVEL COM1 COM2 HORZ VERT ES PRESET SYS MAX LONG 10 OFF OFF 0 REPLACE ONE OF ANY COLORS AMONG COLOR BAR WITH WHITE.(OFF) : SELECT : CHANGE MENU: END User menu (COMN) 3. Press the [] to select TX RATE. 4. Press the [] to display the setting window. 27 5 TX RATE EXT. MIN MAX (EXT., 1-10) TX rate setting window 5. Press the ["] to select EXTERNAL. 6. Press the [MENU] key to close the user menu. Note: Outputting KP of CH-250 to other sonar, echo sounder Transceiver unit 06P0240 J3 KPO 12V positive 2 (E/S transmits, SONAR) GND 6 CH-250 accepts positive KP with amplitude of 0V to 12V. Outputting KP of CH-250 to other sonar, echo sounder g) 28 2.3 Hull Unit Pass the cables to 06P0426 Board through the cable protectors. Fasten glands securely by hands. J2 06P0246 J3 Cable from transducer 06S4081 J1 *Note J1 J2 Cable from transceiver unit 06S4080 *Note TB2 + Power cable 250V-DPYCYS-2.5 - *Note Power Switch Should always be in up (ON). 06P0243 Earth Connect to ship's earth. *Note: Fix the braided shield with cable clamp. 29 2.4 Interface Unit DATA/VIDEO IN DATA/VIDEO OUT RGB OUT Transceiver unit cable 06S4078 Monitor unit cable 06S4078 CONT NMEA VGA NAV monitor Control unit cable 06S4079 Earth Connect to ship's earth. The blackbox type is required to connect a standard VGA monitor via the interface unit IF-8000. Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male, three rows of 15 pins) locally. The monitor used should satisfy the specifications shown below. • • • VGA type ANALOG RGB 0.7 Vpp, positive polarity TLL level H, V, Negative polarity Note: Cut and remove the rubber covers as below to attach connectors to the interface unit.. Remove the fixing metals. Cut and remove the covers. Note: Connect control unit or navigator equipment to either interface unit or monitor unit (supplied by FURUNO). 30 3. ADJUSTMENTS 3.1 General Checks Table 3-1 General checks Check point, Rating Check Item On-keel Installation Retraction tank level Off-keel Installation Within 1 m Clearance between transducer and bottom of retraction tank when transducer is completely retracted by hand crank 1 cm Transducer travel (lowered by hand clank) 400 stroke: Minimum 30 cm Note: When checking, a clearance of approximately 1 meter is required under the bottom of the transducer. Transducer heading 250 stroke: Minimum 22 cm Bow mark on the shaft sleeve should face ship's bow. 31 Table 3-1 general checks (con’t) Check Item Check point, Rating • • Wiring check Rejecting source of noise and interference All lead wires are tightly fixed with contact pins or crimp-on lugs. All screws are firmly fastened. Cables are firmly secured. Cables shields are properly grounded. Noise generating machinery (motor, radiotelephone, TV set, etc.) are not placed nearby. • Magnetic devices are not placed in the vicinity of display unit. Each unit is grounded with a copper strap. Ship’s mains voltage • • Watertightness • Earth 3.2 • • • • All cables are correctly connected. Ship’s mains voltage is stable 12, 24 or 32 VDC. Water should not leak from the main body flange or along the main shaft. TX Frequency Checking Check the TX frequency after the installation. 1. Press the [MENU] key to open the user menu. 2. Press the cursor pad to select SYS at the top of the menu display. MENU COM1 COM2 HORZ VERT GO TO SYS MENU : SELECT YES : CHANGE ES NO MENU: END User menu (SYS) 3. Press the [] to select GO TO SYS MENU. 4. Press the [] to select YES to display the system menu. 32 SHORT-CUT SYS ** SYSTEM MENU ** SYSTEM SETTING: RANGE-SONAR MODE RANGE-VERTICAL MODE RANGE-E/S MODE RANGE-TRACK MODE COLOR PALETTE LANGUAGE SYSTEM BACKUP LOAD BACKUP DATA HEADING OFFSET, DRAFT OFFSET ADJ MOTION SENSOR TX FREQ ADJUST TEST TEST PATTERN DEMO MODE DEFAULT : MENU DISPLAY MENU: END : SELECT System menu 5. Press the [] to select TEST. 6. Press the [] to show the test display. MAIN PROGRAM NO. 0650110-**.** PANEL PROGRAM NO. 0650104-0** ROM : OK RAM : OK VRAM : OK NMEA : OK PANEL CPU : OK TX FREQUENCY : 180 kHz ROLL : 10 PITCH : 10 PULSES NG 359 0 TRAIN TEST COUNT= : 0 REMOTE CONTROL PANEL 1 (LED) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 EXIT 0 0 0 0 0 0 0 ** Program Version No. Test display 7. Check the frequency at the TX FREQUENCY line on the test display. 8. Press the [MENU] key several times to close the menu. 33 3.3 Heading Alignment/Soundome Setting Heading alignment The heading line can be compensated through the system menu ( –30° to +30°). 1. Locate a target (buoy, etc.) in the bow direction and display it on the screen at close range, read deviation. The heading alignment is correct when the target is displayed at 12 o’clock on the screen. Heading 12 o'clock position Buoy When on-screen target is skewed right, transducer heading is skewed left. Checking heading alignment 2. Press the [MENU] key to display the user menu. 3. Press the cursor pad to select SYS at the top of menu display. MENU COM1 COM2 HORZ VERT GO TO SYS MENU : SELECT YES : CHANGE ES NO MENU: END User menu (SYS) 4. Press the [] to select GO TO SYS. 5. Press the [] to select YES to display the system menu. 34 SHORT-CUT SYS ** SYSTEM MENU ** SYSTEM SETTING: RANGE-SONAR MODE RANGE-VERTICAL MODE RANGE-E/S MODE RANGE-TRACK MODE COLOR PALETTE LANGUAGE SYSTEM BACKUP LOAD BACKUP DATA HEADING OFFSET, DRAFT OFFSET ADJ MOTION SENSOR TX FREQ ADJUST TEST TEST PATTERN DEMO MODE DEFAULT : SELECT : MENU DISPLAY MENU: END System menu 6. Press the [] to select HEADING OFFSET, DRAFT OFFSET, and then press the [] to display the heading offset display. ** HEADING OFFSET/DRAFT OFFSET ** HEADING : 0 ˚ (-180˚ - +180˚) DRAFT : 0.0 ˚ (0.0 - 60.0m) : CHANGE : SELECT MENU: END Head offset display 7. Press the [] [] to align heading (1 step) so that the target on heading direction appears at the twelve o’clock position. 8. Press the [] to choose draft. 9. Press the [] [] to set ship’s draft. 10. Press the [MENU] key several times to close the menu. 11. Confirm that the target on heading direction appears at the twelve o’clock position. Soundome setting Confirmation Set the serial number for the soundome connected, under nine-999 or over 1000. 1. Open the SYSTEM MENU following step 1 to 4 in the above. 2. Select SYSTEM SETTING, and then press the [] to open the SYSTEM SETTING 1 menu. 35 ** SYSTEM SETTING 1 ** MENU 1 2 : SHIP'S L/L SHIP'S LOP : OFF ON POSITION TRACK CURRENT DATA : OFF HEADING INDICATION : TRUE FLOW FROM AZ CURSOR L/L FLOW TO NORTH MARK : OFF ON CSE DATA NAV DATA : NAV : GPS GYRO LoranC LoranA DR DECCA OTHERS TVG CORRECTION : OFF 1/2 1/1 UNIT : m ft fa TEMP : TARGET L/L : OFF CUSTOM KEY EMPHASIS MODE ETA MARK : PRESET KEY SHORT-CUT KEY : OFF NORMAL RED 10sec 30sec 1min : OFF : SELECT C : CHANGE HIRO P/B F ON 3min 6min MENU: END System setting 1 menu 3. Press the cursor pad to select 2 and press the [] to show SYSTEM SETTING 2 menu. ** SYSTEM SETTING 2 ** MENU : 1 2 STABILIZER AUTO RETRACTION : OFF : OFF ON (OFF, 5-15 kt) SPEED ALARM/MESSAGE : OFF SWEEP INDICATOR : DOT ON LINE SOUNDOME SER. NO. : ~999 1000~ DEFAULT SETTING : NO YES MAXIMUM ALLOWABLE SPEED IS 15 KNOTS WHILE SOUNDOME IS BEING RETRACTED. IF VESSEL HAS REPAID ACCELERATION CAPABILITIES, AUTO RETRACTION SETTINGS OF 10-12 KNOTS ARE MANDATORY TO AVOID CATASTROPHIC DAMAGE TO SOUNDOME ASSY. ANY PHISICAL DAMAGE TO THE SOUDOME ASSY. IS CONSIDERED ABUSE AND IS NOT A WARRANTY ISSUE. : SELECT : CHANGE MENU: END System setting 2 menu 4. Confirm the soundome serial number at SOUNDOME SER. NO. If change, press [] to select SOUNDOME SER. NO. and then press the [] to select ~999 or 1000~ appropriately. 5. Press the [MENU] key several times to close the menu. 36 3.4 Adjustment of Motion Sensor When the ship has a semi-permanent inclination, offset it as follows. 1. Press the [MENU] key to display the user menu. 2. Press the cursor pad to select SYS at the top of the menu display. MENU COM1 COM2 HORZ VERT GO TO SYS MENU : SELECT YES ES SHORT-CUT SYS NO MENU: END : CHANGE Display to select the system menu 3. Press the [] to select GO TO SYS. 4. Press the [] to select YES. ** SYSTEM MENU ** SYSTEM SETTING: RANGE-SONAR MODE RANGE-VERTICAL MODE RANGE-E/S MODE RANGE-TRACK MODE COLOR PALETTE LANGUAGE SYSTEM BACKUP LOAD BACKUP DATA HEADING OFFSET, DRAFT OFFSET ADJ MOTION SENSOR TX FREQ ADJUST TEST TEST PATTERN DEMO MODE DEFAULT : MENU DISPLAY MENU: END : SELECT System menu 5. Press the [] to select ADJ MOTION SENSOR, and then press the [] to display ADJ MOTION SENSOR menu. ** ADJ MOTION SENSOR ** ROLL ANGLE: 0˚ ADJ: +5 ˚ (-10˚ - +10˚) PITCH ANGLE: 0˚ ADJ: +5 ˚ (-10˚ - +10˚) : SELECT : CHANGE MENU: END Adj motion sensor menu 37 6. Press [] [] to select ROLL ANGLE or PITCH ANGLE. 7. Press [] [] to adjust (-10° to +10°). By using a clinometer or other means, measure ship’s semi-permanent inclination angle. Take the polarity of the angle as follows. For example, if the stern is 3° down, set -3°. + – 0 + 0 – + - ROLL ANGLE Starboard up Starboard down PITCH ANGLE Stern up Stern down 8. Press the [MENU] key several times to close the menu. 3.5 System Back Up After setting the equipment follow the procedure below to back up system settings. Backup data can be loaded in the event of equipment trouble, to restore previous system settings. 1. Press the [MENU] key to display the user menu. 2. Press the cursor pad to select SYS at the top of the menu. MENU COM1 COM2 HORZ VERT GO TO SYS MENU : SELECT YES : CHANGE ES SHORT-CUT NO MENU: END Display to select the system menu 3. Press [] to select GO TO SYS MENU. 4. Press [] to select YES. The system menu appears. 38 SYS ** SYSTEM MENU ** SYSTEM SETTING: RANGE-SONAR MODE RANGE-VERTICAL MODE RANGE-E/S MODE RANGE-TRACK MODE COLOR PALETTE LANGUAGE SYSTEM BACKUP LOAD BACKUP DATA HEADING OFFSET, DRAFT OFFSET ADJ MOTION SENSOR TX FREQ ADJUST TEST TEST PATTERN DEMO MODE DEFAULT : MENU DISPLAY MENU: END : SELECT System menu 5. Press [] to select SYSTEM BACKUP. 6. Press [] to display the system backup menu. ** SYSTEM BACK UP** ARE YOU SURE? : NO YES NOTE: OVERWITES PREVIOUS BACKUP DATA : CHANGE MENU: END System backup menu 7. Press [] to select YES. 8. Press the [MENU] key. The backup data is loaded, and then return to the system menu. 9. Press the [MENU] key to return to the normal display. 39 3.6 Setting of Interface Unit Set DIP switch S1 in the interface unit as follows. • The monitor unit MU-100C or the interface unit is connected to DATA/VIDEO OUT port of the interface unit : all OFF. • Nothing is connected to DATA/VIDEO OUT port of the interface unit : all ON. J6* J7* BUFFER J2 THROUGH J1 S1 ON J3 *: J6 and J7 set to "THROUGH" side. Interface unit, DIP switch S1 location External Monitor Processor Unit Interface Unit Monitor Unit S1:All OFF External Monitor Processor Unit Interface Unit S1:All ON Processor Unit External Monitor External Monitor Interface Unit Interface Unit S1:All OFF S1:All ON 40 Input/Output Description The CH-250 can receive/transmit the following sentences in NMEA 0183 format. Input • • • • • • • • • • • • • • • GLL: GPS position VTG: Ground speed/true course DBT: Depth (Ignore talker, NMEA Ver1.5) DBS: Depth (Ignore talker) DPT: Depth (Ignore talker, NMEA Ver2.0) GGA: GPS position/Speed/Course (Ignore talker) VDR: Current direction/current speed (Ignore talker) RMA: Loran C position/LOP/Speed/Course RMC: GPS position/Speed/Course VHW: Water speed/Heading HDG: Heading MTW: Temperature HDM: Heading HDA: Temperature (Ignore talker) HDT: Heading Output • TLL: When entering event mark. Priority (Input) Own ship’s position Course Heading Speed Depth Temperature Current GGA>RMC>RMA>GLL RMC>RMA>VTG HDG>VHW>HDM RMC>RMA>VTG>VHW DPT>DBT>DBS MTW>MDA VDR 41 LOP can be displayed only when RMA is inputted. This page is intentionally left blank. 0#/' #%%'5514+'5 #%%'5514+'5 52#4'2#465 70+6 +056#..#6+10/#6'4+#.5 176.+0' 0#/' #%%'5514+'5 70+6 176.+0' +056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5 /,#52( %2 /,#52( %2 /:575 &2㩂㩥 41*5 :575 (2 %* #5: #5: 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 36; 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 #5: &'5%4+26+10%1&'ͳ 㪉㪅䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍဳᑼ㪆䍘䍎䍢䍼䉕䈚䉁䈜䇯 㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅 㪈㪅㩿㪁㪀ශ䈱䍗㪄䍪䍼䍷⚵ຠ䈲᭽䈮䉋䉍ቯ䈘䉏䉁䈜䇯 㩿㪁㪀㩷㪤㪘㪩㪢㪜㪛㩷㪚㪘㪙㪣㪜㪪㩷㪘㪩㪜㩷㪪㪜㪣㪜㪚㪫㪘㪙㪣㪜㪅 %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ/, Ꮏ᧚ᢱ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ/, Ꮏ᧚ᢱ &+52.#;%18'4 㩔㨺㩎㩨㩀㩔㩨㨺 *':$1.6 5.166'&9#5*'4*'#& ⷺ㩇㩢㩦㩢㩈㩛㩇$ 10641.70+6/1706+0)$#5' ᠲขઃบ %15/'6+%2.7) 㩘㨺㩣㩖㩩㩡㩂㩨 %10641.70+6$4#%-'6 㩉㨽㩅㩖㩨㩡㩃㨹㩎 5'.(6#22+0)5%4'9 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷 ઃዻຠ %10641.70+6 ᠲㇱ ࡙࠾࠶࠻ %*%* ' 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 A-1 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 36; 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 /,#52( %2 :575 /:%9/$%4㩕㩡 /:575 (2 (2 (2 ()/$8#2$( 52 %*/7% &'5%4+26+10%1&'ͳ #5: ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ᵈ⸥䋩㩷䍘䍎䍢䍼ᧃየ䈮㪲㪁㪁㪴䈱ઃ䈇䈢䍳䍤䍍䍢䈲ઍ䈱ဳᑼ㪆䍘䍎䍢䍼䉕␜䈚䈩䈇䉁䈜䇯 㪛㪦㪬㪙㪣㪜㩷㪘㪪㪫㪜㪩㪠㪪㪢㩷㪛㪜㪥㪦㪫㪜㪪㩷㪚㪦㪤㪤㪦㪥㪣㪰㩷㪬㪪㪜㪛㩷㪜㪨㪬㪠㪧㪤㪜㪥㪫㪅 %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ/, Ꮏ᧚ᢱ 5'.(6#22+0)5%4'9 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷 9#5*'4$+0&+0)*'#&5%4'9 㧗㩔㩨㨼㩧㩎㩨㩈㩛㩇( *':$1.6 㨻㩖㩩㩈㨹㩎7+㩈㩛㩇$ $4#%-'6 㩔㩧㩀㩨㨺 /1706+0)$#5' 㩎㩢㩌㩃㩊㩨㨼 ઃዻຠ *117 㩖㨺㩎㩨㩂㩚㩕㩧 ઃዻຠ (75' 㩕㨷㨺㩇㩨 ੍ຠ %10641.&+52.#;70+6 ᠲ㧛␜ㇱ ࡙࠾࠶࠻ %*%* 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 A-2 ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 %4+/210.7) ⌕┵ሶ #5: 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 %1&'01 (8㨻㨿 ⇟ภ 01 %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ ⇛ޓޓ࿑ 176.+0' %*5ޔ%* ᢙ㊂ 36; #5: ㆬᛯޓ61$'5'.'%6'& ㆬᛯޓ61$'5'.'%6'& ㆬᛯޓ61$'5'.'%6'& ㆬᛯޓ61$'5'.'%6'& ㆬᛯޓ61$'5'.'%6'& ↪ㅜ㧛⠨ 4'/#4-5 #5: A-4 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 %1&'01 5/ %1&'01 5/ %1&'01 5/ %1&'01 5/ %1&'01 5/ ဳฬ㧛ⷙᩰ &'5%4+26+105 %1&'01 6;2' 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 ฬޓޓ⒓ 0#/' +056#..#6+10/#6'4+#.5 ฬޓޓ⒓ 0#/' ဳฬ㧛ⷙᩰ &'5%4+26+105 +056#..#6+10/#6'4+#.5 ⇟ภ 01 ⇛ޓޓ࿑ 176.+0' #5: Ꮏ᧚ᢱ %2 6;2' Ꮏ᧚ᢱ %1&'01 A-3 A-5 Y. Hatai D-2 Y. Hatai D-2A Y. Hatai D-5 D-8 D-8 Takahashi T. Takahashi T. D-13 Y. Hatai CH-254/S 400mmストローク 400mm TRAVEL CH-255/S 250mmストローク 250mm TRAVEL 旋回俯仰部 SOUNDOME CH-2542/S 5B1 DOM 06P0244 VHR-3N 1 2 3 J1 XHP-12 TIP1 1 TIP3 2 TIP2 3 TIP4 4 TRP1 5 TRP3 6 TRP2 7 TRP4 8 TR0 9 +12V 10 GND 11 GND 12 J2 TD1 TD2 TD GND B 送受信装置 TRANSCEIVER UNIT CH-253 CH-2541/S CH-2551/S 4B2 PRA 06P0246 VHR-3N J2 CN5 1 TD1 2 TD2 3 TD GND VHR-4N 1 2 3 4 CN3 J3 SIGP+ SIGPNC XHP-3 1 2 3 XH-20 HULL UNIT TRX *3 06S4080,φ13.7 15/30/50m 4B1 DRV 06P0243 SOUNDOME *3 06S4081 3.5/5.2m XHP-12 J2 CN4 1 TIP1 2 TIP3 3 TIP2 4 TIP4 5 TRP1 6 TRP3 7 TRP2 8 TRP4 9 TR0 10 +12V 11 GND 12 GND CN1 J1 XH-20 PWRON-H 1 PWRON-C 2 RLCONT-H 3 RLCONT-C 4 TRM1-H 5 TRM1-C 6 TRM2-H 7 TRM2-C 8 TIM1-H 9 TIM1-C 10 TIM2-H 11 TIM2-C 12 HULLV-H 13 UPLMT-H 14 DNLMT-H 15 TR0-H 16 F0-H 17 TB2 1 (+)12/24-32VDC F1-H 18 2 (-) F2-H 19 COM_C 20 *2 DPYCY-2.5 XH-6 J3 CN7 EXTERNAL 1 +12V KP/SIG 2 KPO 3 KPI 4 SIG 5 EXT-SW 6 GND CN1 J1 R 1 G 2 B 3 HS-N 4 VS-N 5 YC-N 6 TRXTD-A 7 CONTD-A 8 TD-A 9 RD-A 10 PSW-H 11 12VA 12 0V 13 R-GND 14 G-GND 15 B-GND 16 HS-N-GND 17 VS-N-GND 18 YC-N-GND 19 TRXTD-B 20 CONTD-B 21 TD-B 22 RD-B 23 PSW-C 24 12VA 25 DATA/VIDEO IN XM2A-2501 *3 06S4078,φ12 5/10m *2 DPYCY-2.5 TB1 3B3 PWR 06P0242 1 (+)12-32VDC 2 (-) *2 DPYCY-1.5 1 2 5 6 (+)(-) 整流器 RECTIFIER RU-1746B-2 注記 *1)オプション支給。 *2)現地手配。 *3)コネクタは工場で取付済み。 NOTE *1. OPTION *2. LOCAL SUPPLY *3. CONNECTOR PLUG IS FITTED AT FACTORY. J2 CN2 1 R 2 G 3 B 4 HS-N 5 VS-N 6 YC-N 7 TRXTD-A 8 CONTD-A 9 TD-A 10 RD-A 11 PSW-H 12 12VA 13 12VA-GND 14 R-GND 15 G-GND 16 B-GND 17 HS-N-GND 18 VS-N-GND 19 YC-N-GND 20 TRXTD-B 21 CONTD-B 22 TD-B 23 RD-B 24 PSW-C 25 12VA CN1 J3 TRXTD-A 1 TRXTD-B 2 CONTD-A 3 CONTD-B 4 PSW-H 5 PSW-C 6 +12V 7 GND 8 SCAN-REV 9 F.GND 10 CONT DISP MJ-A10 MJ-A10 SPFD SPFD *3 MJ-A10SPF0002,φ9 06S4079 0.15m 06S4085 1.5m 64S4063 5m 2B1 PNL 06P0239 1 2 3 4 5 6 7 8 9 10 J1 TRXTD-A TRXTD-B CONTD-A CONTD-B PSW-H PSW-C +12V GND SCAN-REV F.GND CN3 J1 TD-A TD-B RD-A RD-B NC F.GND リモートコントローラ REMOTE CONTROLLER *1 CH-256 NMEA *3 MJ-A6SPFD 1 2 3 4 5 6 MJ-A6SPF0011-050C/100C MJ-A6SPF0012-050C/100C 5/10m,φ6.0 航法装置 NAV. EQUIPMENT IEC61162-1(NMEA) *2 IV-2sq. SPEAKER 100/110/115/ 200/220/230VAC 1φ, 50/60 Hz 1B1 DISP 06P0238 3B2 TRX 06P0241 XHP-3 J6 CN6 1 SIGP+ 2 SIGP3 NC 12/24-32 VDC 操作部 CONTROL UNIT CH-252 VHR-4N J1 CN5 1 TR1 2 TR2 3 TD GND 4 NC C D J1 CN4 1 PWRON-H 2 PWRON-C 3 RLCONT-H 4 RLCONT-C 5 TRM1-H 6 TRM1-C 7 TRM2-H 8 TRM2-C 9 TIM1-H 10 TIM1-C 11 TIM2-H 12 TIM2-C 13 HULLV-H 14 UPLMT-H 15 DNLMT-H 16 TR0-H 17 F0-H 18 F1-H 19 F2-H 20 COM_C DATA/VIDEO OUT XM2A-2501 S-1 6 表示部ユニット DISPLAY UNIT MU-100C 3B1 CPU 06P0240 CN2 J1 TR1 TR2 TD GND NC 5 J2 REMS0-N REMS1-N REMR0-N REMR1-N REMR2-N +12V GND A 上下動部 RAISE/LOWER DRIVE UNIT 4 1 2 3 4 5 6 7 上下装置 HULL UNIT 3 R/C 2 5m 1 CN2 スピーカ SPEAKER SC-05WR 5m *1 MOTION SENSOR CN-3 J1 SRC-5P *3 12VB 1 ROLL 2 PITCH 3 GND 4 GND 5 S06-9-5 *1 延長ケーブル 5m EXTENSION CABLE *1 06S4037 φ9,10m 動揺検出器 *1 MOTION SENSOR MS-100 または OR 傾斜角検出器 CLINOMETER *1 BS-704 *2 IV-2sq. *2 IV-8sq. DRAWN CHECKED E.MIYOSHI TAKAHASHI.T APPROVED Y. Hatai Mar.6,'06 SCALE DWG. No. TITLE 名称 相互結線図 MASS NAME kg C1316-C01- D CH-250/S カラーLCDサーチライトソナー REF. No. COLOR SEARCHLIGHT SONAR INTERCONNECTION DIAGRAM FURUNO ELECTRIC CO., LTD. 5B1 DOM 06P0244 VHR-3N 1 2 3 J1 XHP-12 TIP1 1 TIP3 2 TIP2 3 TIP4 4 TRP1 5 TRP3 6 TRP2 7 TRP4 8 TR0 9 +12V 10 GND 11 GND 12 J2 TD1 TD2 TD GND B SOUNDOME *3 06S4081 3.5/5.2m 3B1 CPU 06P0240 CN2 J1 TR1 TR2 TD GND NC VHR-4N 1 2 3 4 CN3 J3 SIGP+ SIGPNC XHP-3 1 2 3 XH-20 HULL UNIT TRX *3 06S4080,φ13.7 15/30/50m 4B1 DRV 06P0243 XHP-12 J2 CN4 1 TIP1 2 TIP3 3 TIP2 4 TIP4 5 TRP1 6 TRP3 7 TRP2 8 TRP4 9 TR0 10 +12V 11 GND 12 GND CN1 J1 XH-20 PWRON-H 1 PWRON-C 2 RLCONT-H 3 RLCONT-C 4 TRM1-H 5 TRM1-C 6 TRM2-H 7 TRM2-C 8 TIM1-H 9 TIM1-C 10 TIM2-H 11 TIM2-C 12 HULLV-H 13 UPLMT-H 14 DNLMT-H 15 TR0-H 16 F0-H 17 TB2 1 (+)12/24-32VDC F1-H 18 2 (-) F2-H 19 COM_C 20 *2 DPYCY-2.5 J1 CN4 1 PWRON-H 2 PWRON-C 3 RLCONT-H 4 RLCONT-C 5 TRM1-H 6 TRM1-C 7 TRM2-H 8 TRM2-C 9 TIM1-H 10 TIM1-C 11 TIM2-H 12 TIM2-C 13 HULLV-H 14 UPLMT-H 15 DNLMT-H 16 TR0-H 17 F0-H 18 F1-H 19 F2-H 20 COM_C XH-6 J3 CN7 EXTERNAL 1 +12V KP/SIG 2 KPO 3 KPI 4 SIG 5 EXT-SW 6 GND CN1 J1 R 1 G 2 B 3 HS-N 4 VS-N 5 YC-N 6 TRXTD-A 7 CONTD-A 8 TD-A 9 RD-A 10 PSW-H 11 12VA 12 0V 13 R-GND 14 G-GND 15 B-GND 16 HS-N-GND 17 VS-N-GND 18 YC-N-GND 19 TRXTD-B 20 CONTD-B 21 TD-B 22 RD-B 23 PSW-C 24 12VA 25 DATA/VIDEO IN XM2A-2501 DATA/VIDEO OUT XM2A-2501 インターフェイス ユニット DATA/VIDEO OUT I/F UNIT XM2A-2501 IF-8000 *1 XM2A-2501 DATA/VIDEO IN J1 J2 C VHR-4N J1 CN5 1 TR1 2 TR2 3 TD GND 4 NC J4 XHP-3 J6 CN6 1 SIGP+ 2 SIGP3 NC J2 XM2A-2501 *2 IV-2SQ. スピーカ SPEAKER SC-05WR 5m *1 100/110/115/ 200/220/230VAC 1φ, 50/60 Hz D TB1 3B3 PWR 06P0242 1 (+)12-32VDC 2 (-) *2 DPYCY-1.5 1 2 5 6 (+)(-) MOTION SENSOR CN-3 J1 SRC-5P *3 12VB 1 ROLL 2 PITCH 3 GND 4 GND 5 S06-9-5 *1 延長ケーブル 5m EXTENSION CABLE 整流器 RECTIFIER RU-1746B-2 注記 *2 *1)オプション支給。 IV-8sq. *2)現地手配。 *3)コネクタは工場で取付済み。 *4)送受信装置から表示部までのケーブル長の合計は15m以下であること。 *5)操作部と航法装置は表示部かインターフェイスユニットのどちらか一方のみに接続可能。 NOTE *1. OPTION *2. LOCAL SUPPLY *3. CONNECTOR PLUG IS FITTED AT FACTORY. *4. CABLE LENGTH BETWEEN TRANSCEIVER AND DISPLAY UNIT SHOULD BE 15 m OR LESS. *5. CONNECT CONTROL UNIT AND NAV EQUIPMENT TO EITHER DISPLAY UNIT OR INTERFACE UNIT. MJ-A6SPF0011-050C/100C MJ-A6SPF0012-050C/100C 5/10m,φ6.0 J1 TRXTD-A TRXTD-B CONTD-A CONTD-B PSW-H PSW-C +12V GND SCAN-REV F.GND リモートコントローラ REMOTE CONTROLLER *1 CH-256 MJ-A6SPF0011-050C/100C MJ-A6SPF0012-050C/100C 5/10m,φ6.0 航法装置 *5 NAV. EQUIPMENT IEC61162-1(NMEA) 航法装置 *5 NAV. EQUIPMENT IEC61162-1(NMEA) *4 *3 *1 06S4078 5m,φ12 インターフェイス ユニット I/F UNIT XM2A-2501 IF-8000 *1 DATA/VIDEO IN J1 RGB OUT Dsub-15P J3 CONT MJ-A10SPFD 動揺検出器 *1 MOTION SENSOR MS-100 または OR 傾斜角検出器 CLINOMETER *1 BS-704 1 2 3 4 5 6 7 8 9 10 NMEA *3 MJ-A6SPFD J4 *1 06S4037 φ9,10m 2B1 PNL 06P0239 *2 NMEA MJ-A6SPFD J5 DISP CONT MJ-A10 MJ-A10 SPFD *3 SPFD MJ-A10SPF0002,φ9 06S4079 0.15m 06S4085 1.5m 64S4063 5m 外部モニター IV-2sq. EXT. VGA MONITOR *5 操作部 リモートコントローラ CONTROL UNIT REMOTE CONTROLLER CH-252 CH-256 CONT MJ-A10SPFD CN2 *2 DPYCY-2.5 CN1 J3 J2 CN2 1 R TRXTD-A 1 2 G TRXTD-B 2 3 B CONTD-A 3 4 HS-N CONTD-B 4 5 VS-N PSW-H 5 6 YC-N PSW-C 6 7 TRXTD-A +12V 7 8 CONTD-A GND 8 9 TD-A SCAN-REV 9 10 RD-A F.GND 10 11 PSW-H 12 12VA 13 12VA-GND 14 R-GND 15 G-GND 16 B-GND 17 HS-N-GND 18 VS-N-GND 19 YC-N-GND CN3 J1 20 TRXTD-B TD-A 1 21 CONTD-B TD-B 2 22 TD-B RD-A 3 23 RD-B RD-B 4 24 PSW-C NC 5 25 12VA F.GND 6 J3 SPEAKER 12/24-32 VDC 1B1 DISP 06P0238 RGB OUT Dsub-15P 3B2 TRX 06P0241 操作部 CONTROL UNIT CH-252 *5 J2 REMS0-N REMS1-N REMR0-N REMR1-N REMR2-N +12V GND 旋回俯仰部 SOUNDOME CH-2542/S 表示部 DISPLAY UNIT MU-100C 1 2 3 4 5 6 7 VHR-3N J2 CN5 1 TD1 2 TD2 3 TD GND TRANSCEIVER UNIT R/C 4B2 PRA 06P0246 S-2 6 5m CH-254/S 400mmストローク 400mm TRAVEL CH-255/S 250mmストローク 250mm TRAVEL 送受信装置 CH-253 CH-2541/S CH-2551/S 5 *3 *4 06S4078,φ12 5/10m A 上下動部 RAISE/LOWER DRIVE UNIT 4 SELECT 上下装置 HULL UNIT 3 選択 2 *3 *4 06S4078,φ12 5/10m 1 NMEA MJ-A6SPFD J5 外部モニターNo.2 EXT. VGA MONITOR No.2 操作部 *5 リモートコントローラ REMOTE CONTROLLER CONTROL UNIT CH-256 CH-252 MJ-A6SPF0011-050C/100C MJ-A6SPF0012-050C/100C 5/10m,φ6.0 航法装置 *5 NAV. EQUIPMENT IEC61162-1(NMEA) *2 IV-2sq. *2 IV-2sq. DRAWN CHECKED E.MIYOSHI TAKAHASHI.T APPROVED Y. Hatai Mar.6,'06 SCALE DWG No. TITLE 名称 相互結線図 MASS NAME kg C1316-C02- D CH-250/S カラーLCDサーチライトソナー(I/Fユニット使用) REF. No. COLOR SEARCHLIGHT SONAR (W/ I/F UNIT) INTERCONNECTION DIAGRAM FURUNO ELECTRIC CO., LTD.