Download Furuno SEARCHLIGHT CH-250 User's Manual

Transcript
Installation Manual
SEARCHLIGHT SONAR CH-250
SAFETY INSTRUCTIONS....................... i
3. ADJUSTMENTS ............................... 31
3.1 General Checks..................................... 31
SYSTEM CONFIGURATION ................. iii
3.2 TX Frequency Checking........................ 32
EQUIPMENT LISTS .............................. iv
3.3 Heading Adjustment/Soundome Setting
......................................................... 34
1. Mounting ........................................... 1
1.1 Monitor Unit/Control Unit .........................1
1.2 Transceiver Unit .......................................6
1.3 Hull Unit ...................................................9
1.4 Interface Unit..........................................21
3.4 Adjustment of Motion Sensor ................ 37
3.5 System Back Up.................................... 38
3.6 Setting of Interface Unit......................... 40
Input/Output Description.................... 41
1.5 Motion Sensor MS-100 (option) .............22
2. Wiring .............................................. 23
PACKING LISTS ................................ A-1
2.1 Wiring among Units................................23
OUTLINE DRAWINGS ....................... D-1
2.2 Transceiver Unit .....................................26
2.3 Hull Unit .................................................29
INTERCONNECTION DIAGRAMS..... S-1
2.4 Interface Unit..........................................30
www.furuno.co.jp
The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
Telephone : +81-(0)798-65-2111
Fax
: +81-(0)798-65-4200
All rights reserved.
Printed in Japan
A : MAR . 2000
K4 : SEP . 10, 2007
Pub. No. IME-13160-K4
(YOSH )
CH-250
*00080895011*
*00080895011*
* 0 0 0 8 0 8 9 5 0 1 1 *
SAFETY INSTRUCTIONS
WARNING
WARNING
Installe the specified transducer tank
in accordance with the installation
instructions. If a different tank is to be
installed the shipyard is solely responsible for its installation, and it should
be installed so the tank doesn't strike
an object.
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
Only qualified personnel
should work inside the
equipment.
Turn off the power at the switchboard
before beginning the installation.
The tank or hull may be damaged if the
tank strikes an object.
Fire or electrical shock can result if the
power is left on.
If a steel tank is installed on a wooden
or FRP vessel, take appropriate
measures to prevent electrolytic
corrosion.
Do not install the equipment where it
may get wet from rain or water splash.
Electrolytic corrosion can damage the hull.
Water in the equipment can result in fire,
electrical shock or equipment damage.
Be sure that the power supply is
compatible with the voltage rating of
the equipment.
Be sure no water leaks in at the transducer installation site.
Connection of an incorrect power supply
can cause fire or equipment damage.
The voltage rating of the equipment appears
on the label above the power connector.
Water leakage can sink the vessel.
Also confirm that the transducer will not
loosen by ship's vibration.
The installer of the equipment is solely
responsible for the proper installation of the
equipment. FURUNO will assume no
responsibility for any damage
associated with improper installation.
i
CAUTION
CAUTION
Ground the equipment to
prevent electrical shock and
mutual interference.
WORKING WITH THE SONAROIL
Precautions
Keep oil away from eyes. Wear protective
gloves when working with the oil. The oil
can cause inflammation of the eyes.
Observe the following compass safe
distances to prevent deviation of a
magnetic compass:
Standard
Monitor unit/
Control unit
0.80 m
Transceiver
unit
0.50 m
Interface
unit
0.95 m
Do not touch the oil. Wear protective
gloves when working with the oil. The oil
can cause inflammation of the skin.
Steering
0.55 m
Do not ingest the oil. Diarrhea or vomiting
can result.
0.35 m
Keep the oil out of reach of children.
0.65 m
Emergency
If the oil enters eyes, flush with clean
water about 15 min. Consult a physician.
Install the monitor unit MU-100C out of
direct sunlight.
If the oil contacts skin, wash within soap
and water.
It is difficult to see the display in direct
sunlight.
If the oil is ingested, see a physician
immediately.
Turn the main power off before this check,
otherwise the raise/lower motor action
may cause injurely
Disposal of oil and its container
Dispose of oil and its container in
accordance with local regulations.
For further details, contact place of
purchase.
Storage
Seal container to keep out foreign
material. Store in dark place.
ii
SYSTEM CONFIGURATION
INTERFACE UNIT IF-8000
Note 2
MONITOR UNIT MU-100C
Navigator
Control Unit
Display
Unit
Note 1
VGA Ext.
Monitor
Remote
Controller
Note 2
TRANSCEIVER UNIT
CH-253
CONTROL UNIT CH-252
MOTION SENSOR
12-32 VDC
HULL UNIT
SPEAKER
DATA/VIDEO OUT
12-32 VDC
Speaker
HULL UNIT
CH-254/255
Motion Sensor
12/24-32 VDC
Note 1: MU-100C is the standard supply
display unit. An external monitor
may be connected via the
interface unit (option). The drawing
above shows the system configuration
with the MU-100C.
Note 2: For blackbox type, MU-100C is
not supplied. Connect external
monitor (user supply) and control
unit to the interface unit.
iii
EQUIPMENT LISTS
Standard Supply
Name
Control Unit/
Monitor Unit
Control Unit
Interface Unit
Transceiver Unit
Hull Unit
Spare Parts
Type
CH-252/
MU-100C
CH-252
IF-8000
CH-253
CH-254
Code no.
Remarks
1
Not supplied with blackbox type
1
1
1
Not supplied with unibody type
For blackbox type
See the following
table for Hull Unit
250 stroke
Standard Supply.
For unibody type, SP06-01102*,
SP06-01103*
For blackbox type, SP06-01102*,
SP06-01111*, SP06-01103*
For unibody type
CP06-01251* and two cables (page
viii)
For unibody type, FP02-05101*,
FP06-01102*
For blackbox type
Hard cover
For blackbox type
400 stroke
1
CH-255
SP06-01100
000-068-488
SP06-01110
000-068-489
SP06-01101*
006-556-200
1
Installation
Materials
Accessories
Qty
1
FP02-05100
000-012-474
FP06-01120*
006-556-260
06-021-2121
100-320-101
1
1
*: See the lists at the back of this manual.
iv
Hull Unit (1)
Code no.
Type
000-068-515
000-068-516
000-068-517
000-068-518
000-068-519
000-068-559
000-068-560
000-068-561
000-068-562
000-068-563
000-068-520
000-068-521
000-068-522
000-068-523
000-068-524
000-068-525
000-068-526
000-068-527
000-068-528
000-068-529
000-068-564
000-068-565
000-068-566
000-068-567
000-068-568
000-068-530
000-068-531
000-068-532
000-068-533
000-068-534
000-068-535
000-068-536
000-068-537
000-068-538
000-068-539
000-068-540
000-068-543
000-068-544
000-068-547
000-068-548
000-068-569
000-068-570
000-068-571
000-068-572
000-068-573
000-068-549
000-068-550
000-068-551
000-068-552
000-068-553
000-068-554
000-068-555
000-068-556
000-068-557
000-068-558
000-068-574
000-068-575
000-068-576
000-068-577
000-068-578
CH-254-1-60-22-35
CH-254-1-88-22-35
CH-254-1-150-22-35
CH-254-1-180-22-35
CH-254-1-240-22-35
CH-254-1-60-22-52
CH-254-1-88-22-52
CH-254-1-150-22-52
CH-254S-1-180-22-52
CH-254S-1-240-22-52
CH-254-1-60-38-52
CH-254-1-88-38-52
CH-254-1-150-38-52
CH-254S-1-180-38-52
CH-254S-1-240-38-52
CH-254-2-60-22-35
CH-254-2-88-22-35
CH-254-2-150-22-35
CH-254S-2-180-22-35
CH-254S-2-240-22-35
CH-254-2-60-22-52
CH-254-2-88-22-52
CH-254-2-150-22-52
CH-254S2-180-22-52
CH-254S-2-240-22-52
CH-254-2-60-38-52
CH-254-2-88-38-52
CH-254-2-150-38-52
CH-254S-2-180-38-52
CH-254S-2-240-38-52
CH-255-1-60-22-35
CH-255-1-88-22-35
CH-255-1-150-22-35
CH-255S-1-180-22-35
CH-255S-1-240-22-35
CH-255-1-60-38-52
CH-255-1-88-38-52
CH-255-1-150-38-52
CH-255S-1-180-38-52
CH-255S-1-240-38-52
CH-255-1-60-22-52
CH-255-1-88-22-52
CH-255-1-150-22-52
CH-255S-1-180-22-52
CH-255S-1-240-22-52
CH-255-2-60-22-35
CH-255-2-88-22-35
CH-255-2-150-22-35
CH-255S-2-180-22-35
CH-255S-2-240-22-35
CH-255-2-60-38-52
CH-255-2-88-38-52
CH-255-2-150-38-52
CH-255S-2-180-38-52
CH-255S-2-240-38-52
CH-255-2-60-22-52
CH-255-2-88-22-52
CH-255-2-150-22-52
CH-255S-2-180-22-52
CH-255S-2-240-22-52
Spec.
Stroke
400 mm
Power
12 V
24 V-32 V
250 mm
12 V
24 V-32 V
v
Frequency
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
60 kHz
88 kHz
150 kHz
180 kHz
240 kHz
Shaft
2.2 m
Cable
3.5 m
2.2 m
5.2 m
3.8 m
5.2 m
2.2 m
3.5 m
2.2 m
5.2 m
3.8 m
5.2 m
2.2 m
3.5 m
3.8 m
5.2 m
2.2 m
5.2 m
2.2 m
3.5 m
3.8 m
5.2 m
2.2 m
5.2 m
Hull Unit Standard Supply
Name
Raise/lower
Drive Unit
Soundome
Type
CH-2541
CH-2551
CH-2542
Code no.
-
Flange
Assembly Kit for
field
CH-2543
CH-2544
006-557-810
006-557-820
1 set
1 set
Shaft
SHJ-0006-1
06-007-1572-0
4 lit.
661-000-061
600-715-720
000-824-033
1
Sonar Oil
vi
Qty
1 set
1 set
1
Remarks
See the following Soudome
table.
Flange, grease cotton
Shaft, retraction tank, seal,
adhesives, tank guide,
material box
2.2 m, for 3.5/5.2 m cable
3.8 m, for 5.2m cable
Shaft parts
Name
Pipe cap
Jubilee Clip
Hex. bolt
U-nut
Flat washer
Type
SHN-0011-0
1X28-41
M10X35 SUS304
M10 SUS304
M10 SUS304
Code no.
661-400-110
000-801-857
000-862-175
000-863-930
000-864-131
Qty
1
1
2
2
4
Remarks
Type
M20X80 SUS304
M20 SUS304
M20 SUS304
M20 SUS304
Code no.
000-801-893
000-863-116
000-864-136
000-864-270
Qty
8
16
16
8
Remarks
Code no.
000-801-328
000-854-104
000-856-520
Qty
1
1
1
Remarks
Anti-corrosion
Sealant, 200g
adhesive
Code no.
006-557-200
Qty
1
Remarks
Tank parts
Name
Hex. bolt
Hex. nut
Flat washer
Spring washer
Adhesives
Name
Kinolastar
Three Bond
Cemedine High Super
Type
855
1104
6G
Tank guide
Name
Tank guide
Type
CH-2544
Assembly kit for field (Material Box)
Name
Socket set screw
Shim (0.5)
Shim (1.0)
Shim (2.0)
Type
TWB-40
06-021-4035
06-021-4036
06-021-4037
Code no.
000-804-423
100-295-420
100-295-430
100-295-440
vii
Qty
1
2
2
4
Remarks
4 mm
0.5 mm
1.0 mm
2.0 mm
Cables for Installation materials
Type
CP06-01200
CP06-01201
CP06-01202
CP06-01203
CP06-01204
CP06-01205
Code no.
000-068-496
000-068-497
000-068-498
000-068-499
000-068-500
000-068-502
Specification (Cable between unit)
Monitor unit (or IF)
Transceiver unit and Hull unit
and Transceiver unit
06S4078*5m*
06S4080*15m*
06S4080*30m*
06S4080*50m*
06S4078*10m*
06S4080*15m*
06S4080*30m*
06S4080*50m*
Crimp-on lug
CP06-01251*
CP06-01251*
CP06-01251*
CP06-01251*
CP06-01251*
CP06-01251*
Control unit cable
Type
Code no.
Qty
Remarks
CP02-06600*
000-012-486
1
MJ-A10SPF0002-0015, for unibody type
CP02-06610*
000-012-480
1
MJ-A10SPF0002-015, 1.5 m
CP02-06620*
000-012-481
For blackbox type
MJ-A10SPF0002-050, 5 m
*: See lists at the back of this manual.
Options
Name
Remote Controller
Interface Unit
Motion Sensor
Speaker
Signal Cable
Cable assy.
Control Unit
Separate Kit
Flush mount kit
Control unit flush
mount kit
Rectifier
Tank
Type
CH-256-E
IF-8000
MS-100
SC-05WR
S06-9-5
MJ-A6SSPF0012-050
MJ-A6SSPF0012-100
MJ-A6SSPF0011-050
MJ-A6SSPF0011-100
OP06-15-1.5 NEW
OP06-15-5 NEW
OP02-83-1.5
OP02-83-5
OP06-16
OP06-17
OP06-18
Code no.
000-068-492
000-068-495
000-136-156
006-556-270
000-134-424
000-133-817
000-132-244
000-132-336
006-559-140
006-559-150
001-413-600
001-413-610
006-556-300
006-556-310
006-556-320
1
1
1
1
1
RU-1746B-2
06-007-1570-1
SHJ-0001-1
06-007-1571-1
06-021-4024-0
06-007-1573-0
OP10-5
000-030-439
600-715-701
661-000-011
600-715-711
100-295-470
600-715-730
000-069-763
1
1
1
1
1
1
1
viii
Qty
1 set
1 set
1 set
1
1
1
1
Remarks
Extension cable for speaker
6pin-6pin, 5m
6pin-6pin, 10m
6pin-4pin, 5m
6pin-4pin, 10m
For desktop, with 1.5 m
For desktop, with 5 m
For flush mount, with 1.5 m cable
For flush mount, with 5m cable
For unibody type
For separate type display unit
Steel, 1m
Steel, 1.8m
Steel, 3.5m
FRP, 1m
FRP, 1.8m
Aluminum, 1m
1. Mounting
NOTICE
Do not apply paint, anti-corrosive sealant
or contact spray to coating or plastic
parts of the equipment.
Those items contain organic solvents that
can damage coating and plastic parts,
especially plastic connectors.
1.1 Monitor Unit/Control Unit
This searchlight sonar has two types of shipment, standard type which is shipped with monitor
unit and blackbox type which is shipped without monitor unit, but has interface unit. For
blackbox type, see page 4.
The control unit can be installed together with the monitor unit, or independently of the monitor
unit. On installing separately, the optional monitor kit is required. These units can be installed on
a tabletop or flush mounted in a console or panel.
1.1.1
•
•
General mounting considerations
Keep the monitor unit out of direct sunlight.
Select a location where the unit(s) can easily be operated while observing the fishing ground
or area surrounding the vessel.
•
For maintenance and checking purposes, leave sufficient space at the sides and rear of the
unit and leave slack in cable. (Refer to the outline drawing at the back of this manual.)
•
A magnetic compass will be affected if place too close to the monitor unit. Observe the
following compass safe distance to prevent deviation to a magnetic compass: Standard
compass: 0.80 m, Steering compass: 0.55 m.
1.1.2
Mounting method of monitor unit (Standard type)
1. Fasten the mounting base to the mounting location with four tapping screws.
FRONT
Mounting base
1
2. For unibody mounting;
a) Fasten the bracket at the rear of monitor and control units with four binding screws (M4x10).
1
Bracket (rear view)
1
2
2
3
3
4
4
Bracket, rear view
3. For separate/blackbox mounting;
a)
Dismount the coupling plate to separate monitor unit and control unit.
b)
Attach the bracket at rear of the monitor unit with four binding screws (M4x10).
Bracket (rear view)
1
1
3
2
2
4
3
4
Bracket, rear view
4. Coat threads of upset screws (M6x16, 2 pcs.) used to fasten bracket to mounting base.
5. Fasten the bracket to the mounting base with two upset screws. (Use the upper holes to tilt
the monitor unit 20°; lower holes to tilt it 9°.)
MOUNTING
BASE
HANGER
Upset Screw
Fastening hanger to mounting base
2
Flush mounting
Flush mounting for unibody (Type: OP06-16, Code no.: 006-556-300)
Name
Type
Code No.
Qty
Fixing metal
06-021-1311-2
100-279-612-10
1
Self-tapping screw
5x20
000-162-609-10
6
Hex. bolt
M4x12
000-162-939-10
4
Remarks
1. Make holes at the place to mount (W287 x H297).
2. Fasten monitor and control units with the fixing metal (supplied as option) and four hex.
bolts (supplied as option).
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with six tapping screws
(supplied as option).
Hex. Bolts
Fixing metal
Flush mounting for monitor unit (Type: OP06-17, Code no. 006-556-310)
Name
Type
Code No.
Qty
Fixing metal
06-021-1321-2
100-279-622-10
1
Self-tapping screw
5x20
000-162-609-10
4
Hex. bolt
M4x12
000-162-939-10
4
Remarks
1. Make holes at the place to mount (W287 x H207).
2. Fasten the fixing metal (supplied as option) to the monitor unit with four hex. bolts (M4x12,
supplied as option).
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping
screws (5x20, supplied as option).
3
Hex. Bolts
Fixing Metal
Flush mounting for control unit Type:
OP02-83-1.5, Code no.: 001-413-600 (1.5 m cable)
OP03-83-5, Code no.: 001-413-610 (5m cable)
Name
Type
Code No.
Qty
Remarks
Fixing metal
06-021-2101-2
100-279-732-10
1
Self-tapping screw
5x20
000-162-609-10
4
Hex. bolt
M4x12
000-162-939-10
2
Cable assembly
MJ-A10SPF0002-0
15
000-142-878
1
1.5 m
MJ-A10SPF0002-0
50
000-131-411
1
5m
Select one.
1. Make holes at the place to mount (W287 x H87).
2. Fasten the fixing metal to the control unit with two hex. bolts (supplied as option).
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping
screws (supplied as option).
Hex. Bolts
Fixing metal
1.1.3
Blackbox type
The blackbox type is required to connect a standard VGA monitor via the interface unit IF-8000.
Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male,
three rows of 15 pins) locally. The monitor used should satisfy the specifications shown below.
•
•
•
VGA type
ANALOG RGB 0.7 Vpp, positive polarity
TLL level H, V, Negative polarity
4
1.1.4
Control unit
On blackbox type, fix the control unit to the mounting plate (supplied as accessories).
See the parts list of FP06-01120 and outline drawings at the back of this manual.
1. Fix the mounting plate to the place selected with two tapping screws (5x20, supplied).
2. Fix the bracket to the control unit with two hex. screws (M4x12, supplied).
3. Insert the screw driver from the top of the mounting plate holes and then tighten two hex.
screws (M4x12) loosely.
4. Attach the control unit to the mounting plate, and fasten two hex. screws tightly.
5. Attach two cosmetic caps to holes at the top of the mounting plate.
Mounting plate
Cable entrance hole
Cable
Fasten the screws to fix
the bracket.
Tapping screws (5x20)
Insert to the hex.
screws tightened
at step 3.
Bracket
Bracket
Cable can be passed this direction.
6. Attach hard cover to protect the control unit.
How to remove the hard cover
Place your thumbs at the locations shown with
circles in the illustration at right, and then lift the
cover while pressing it with your thumbs.
On mounting the control unit separate from the monitor unit, the optional control unit separate kit
is required. Mount the control unit same as the above procedure. See the outline drawing at the
back of this manual to mount.
Type: OP06-15-1.5 NEW
Code no.: 006-559-140: with 1.5 m cable
Type: OP06-15-5 NEW
Code no.: 006-559-150: with 5 m cable
Name
Cable
Type
Code no.
Qty
MJ-A10SPF0002-015
000-142-878
MJ-A10SPF0002-050
000-131-411
Bracket
06-021-2112
100-281-880-10
1
Mounting Plate
06-021-2111-1
100-279-741-10
1
Tapping Screw
5x20
000-162-608-10
2
Cosmetic Cap
DP-687
000-165-997-10
2
Hex. Screw
M4x12
000-162-939-10
4
Bind Screw
M4x10
000-807-331
4
5
1
Remarks
For 1.5 m cable
For 5 m cable
For monitor
1.2
Transceiver Unit
1.2.1
General mounting considerations
•
•
•
The mounting location should be well ventilated and dry.
The unit can be mounted on bulkhead or the deck.
Secure the maintenance space shown in drawing below for ease of maintenance and
service.
•
The maximum cable length between the transceiver unit and the raise/lower drive unit cable
is 50 m.
•
The maximum cable length between the transceiver unit and the monitor (interface) unit is
10 m.
1.2.3
Mounting method
Fasten the transceiver unit with four tapping screws (5X20, local supplied).
For bulkhead mounting, tighten upper tapping screws so there is 5 mm clearance between
bottom of screw head and bulkhead, and screw slots of the unit. Then fasten lower screws.
1.3
Hull Unit
1.3.1
General mounting considerations
•
•
Noise and air bubbles will affect performance.
Do not turn on the equipment with the transducer exposed to air. Exposing the transducer to
air may damage it.
1.3.2
Installation position considerations
Discussion and agreement are required with the dockyard and ship owner in deciding the
location for the hull unit. When deciding the location, take into account the following points:
•
Select an area where propeller noise, cruising noise, bubbles and interference from
turbulence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s length from the bow or
near the keel is the best. On-the-keel installation is advantageous for minimizing oil
consumption in comparison with of-the-keel. If the hull unit cannot be installed on the keel,
the center of the retraction tank should be within 1 meter of the keel to prevent a rolling
effect.
6
1/3
1/2
Within 1 meter
Installation location for hull unit
•
Select a place where interference from the transducers of other sounding equipment is
minimal. The hull unit should be at least 2.5 meters away from the transducers of other
sounding equipment.
•
An obstacle in the fore direction not only causes a shadow zone but also aerated water,
resulting in poor sonar performance. Be sure to locate the transducer well away from any
obstacle in the fore direction.
Mounting method
A typical mounting method is shown in the outline drawing at the back of this manual. Consult
ship’s owner, dockyard and user to determine appropriate mounting method. Pay attention to
safety (strength, watertightness) first, followed by ease of maintenance and inspection.
1.3.3
Transducer tank
Tank length
Shorten the transducer tank so the transducer is
Wealding bead
lowered into water as deep as possible. Pay particular
attention to the tank length Lt. Determine the length of
the main shaft.
•
•
Length of main shaft = Lt + 200 mm (for 400 stroke)
Length of main shaft = Lt + 50 mm (for 250 stroke)
Note : When the retraction tank is constructed locally,
finish it so that welding beads do not protrude on
the inner surface of the tank. The tank guide will hit
the bead, burning out the raise/lower motor. Also,
do not position the welding bead in the ship’s
fore-aft line.
7
Wealding bead
For small FRP ship
For small FRP ship retraction tank should be 2 degrees against ship’s draft. Therefore, this
creates high water pressure in the tank because of the resistance at the rear of the tank well. To
solve this problem, attach a fin to the hull at the location shown in figure below.
Retraction dome
Bottom of ship
Fin
This fin makes a smooth stream in the retraction dome. Attach the fin (height:1-1.5 cm, FRP).
Mounting of transducer tank
Install the transducer tank referring to the hull unit outline drawings at the back of this manual.
Note 1: When making a retraction tank locally, the inside diameter of the retraction tank should
not be more than φ190±0.5 as shown on outdrawing at the back of this manual. If larger,
the hull unit may be danger.
Note 2: Locate the retraction tank so that the center of any two bolt holes is facing the ship’s
bow.
a=b
a
b
8
Bow
1.3.4
Assembling and mounting of hull unit
The hull unit is shipped as the parts shown in the hull unit kit on Equipment Lists (page iv and
after). Assemble the hull unit as shown in the procedure below.
Necessary tools
Name
Specification
Remarks
Wrench
For M10 (Hex. size 17 mm)
Wrench
For M20 (Hex. size 20 mm)
Pipe Wrench
55 mm
For fixing gland
Ball Wrench
Hex size 4 mm
For fixing the dome
Recommended: double offset
wrench
1. Calculate necessary length of main shaft from the length of retraction tank Lt and cut off the
spare portion. When 1 m or 1.8 m long tank is used, main shaft (1.17 m or 1.97 m) can be
used without cutting off any portion.
Supplied length: 2.2 m or 3.8 m
Lt + 200 mm for 400 mm stroke
Lt + 50 mm for 250 mm stroke
Chamfer the edge to
protect O-ring from
damage.
Take care
not to damage.
2. Remove hex bolt, nut, spring washers, flat washers and trunnion pins from the main body
flange. And then, mount the raise/lower drive unit on the shaft sleeve by using the hardware
removed.
9
ING
RN
WA
WA
RN
ING
Raise/lower
section
Flat
Nut
washer
Hex. bolt
(M10X30)
Shaft sleeve
Spring washer
Flat washer
Trunnion pin
Shaft sleeve and raise/lower drive unit assembly
3. Pass the transducer cable through the main shaft.
10
4. Fully screw main shaft into the soundome neck, and then unscrew by four turns. Coat
threads with adhesive (HIGH SUPER).
Main Shaft
Grasp the soundome neck with a wrench,
and tighten the shaft with a pipe wrench.
Coat threads with adhesive
(HIGH SUPER).
Applying Adhesive (HIGH SUPER) to main shaft
5. Screw in main shaft completely.
6. As shown in the drawing below, confirm that the narrowest gap between the tank guide, and
retraction tank in the range (20 to 170 mm) is within 0.5 mm.
Slide range
(Stroke) 250 or 400
Retraction tank
20 mm (400 stroke) 170 mm (250 stroke)
Tank guide
less than 0.5mm
Tank and tank guide, sectional view
11
7. If the gap at a side is more than 0.5 mm, install a shim to make the gap within 0.5 mm.
a) Unscrew four M10x50 bolts.
b) Unscrew four countersunk screws, then attach the shim with the countersunk screws as
shown below.
Nut
Flat washer
Countersunk screw
(M4x16)
Hex. bolt
(M10x70)
Guide plate
Shim (1.0)
Flat washer
Shim (1.5)
Spring washer
Hex. bolt
(M10X50)
Installing shims
12
The table below shows tank length and necessary shim thickness. In addition, the shim
thickness shown is for one side. For example, when cutting the 1800 mm tank to 800 mm, the
1800
8
1600
7
1400
6
1200
5
1000
4
800
3
600
400
2
200
1
0
0
194
189
190
191
192
193
Tank inside dia. Φ B (mm)
Shim thickness (mm)
Length A (mm) tank shortened
tank inside diameter is 191.25 mm, shim thickness is 2.5 mm as shown the table in below.
For 1 m tank
For 1.8 m tank
Shim thickness
The table below shows number of shims required and shim thickness.
Shim thickness
0
t2.0
t1.0
t0.5
Inside dia of tank 188.1
0.5
1
188.7
1
1.5
1
1
1
189.9
189.3
2
1
2.5
1
190.5
1
191.1
13
3
1
1
191.7
3.5
1
1
1
192.3
4
2
4.5
2
192.9
1
193.5
5
2
1
194.1
5.5
2
1
1
194.7
6
2
2
195.3
6.5
2
2
1
195.9
8. Apply THREE BOND 1104 to the inside of tank guide. And then, fasten tank guide at the
neck* of the main shaft securely with M10X80 bolts.
Hex. Bolt
(M10X80)
: coated with THREE BOND 1104
Flat washer
Spring Washer
Nut
*
Bow Mark
Bow
Face the tank guide
toward ship's bow.
Tank guide attachment
9. Pass the main shaft through shaft sleeve.
10. Pass the main shaft through the shaft retainer at the raise/lower drive unit.
Pipe cap
U-nut
Shaft retainer
Spring washer
Hex. bolt M10X35
Bow mark
Main body flange
14
11. Face the bow mark on the soundome with the bow mark on the shaft sleeve, and then fix
the main shaft with and shaft retainer.
12. Fix the jubilee clip to the main shaft.
Hex. bolt
Shaft retainer
15 mm
1-2 mm
Jubilee Clip
Main shaft
Note: Attach the shaft retainer so it is 15 mm from the top of the shaft. The soundome is then
placed 10 mm above the bottom of tank when retracted.
13. Insert grease cotton (supplied with shaft sleeve), and fix them with the cotton retainer as
follows.
a) Wind grease cotton onto main shaft.
b) Mark on the cotton as below.
c) Remove the cotton from the shaft, and then cut it at the position of the mark. Discard the ends.
d) Wind cottons as shown below.
e) Push cottons into the main body flange.
f)
Tighten the grease cotton retainer.
Wind grease cotton
onto main shaft and
cut it as shown below.
Space joints of grease cotton
120 apart and push them into
body flange.
Spring washer
Cotton retainer
Installing grease cotton on the main shaft
14. Fasten the pipe cap (supplied) to main shaft.
15. Unscrew 10 pcs of M5X35 socket head cap screws with soundome fixing tool to separate
soundome.
15
Rotate 4 or 5
turns by hand
to make sure
that turning
mechanisms
are functioning
properly.
Socket head cap screw
10pcs, M5x30
Spring washer
O-ring
Remove.
Apply KINORUSTER.
Soundome
Protection sponge
Detaching the soundome
16. Throw away protection sponge placed in soundome.
17. Stand the soundome upright on top of the soundome packing. Fill the soundome with oil
(supplied) so the level is 5 cm on the top of the soudome. Keep the soundome packing for
future use.
Ball wrench
Sonar oil
5 cm
Stand the soundome upright
on top the soundome packing.
Filling the soundome with sonar oil
16
CAUTION
Keep oil away from eyes. Where protective
goggles when working with the oil. The oil
cause inflammation of the eyes.
Do not touch the oil. The oil can cause
inflammation of the skin. Wear protective
gloves when working with the oil.
Do not ingest the oil. Diarrhea or vomiting
can result.
Keep the oil out of reach of children.
EMERGENCY
If the oil enters the eyes, flush with clean
water about 15 minutes. Consult a
physician. If oil contacts skin, wash with
soap and water. If the oil is ingested, see a
physician immediately.
DISPOSAL OF OIL AND ITS CONTAINER
Dispose of oil and its container in
accordance with local regulations.
For further information,contact place of
purchase.
STORAGE
Seal container to keep out foreign material.
Store in dark place.
18. Rotate the transducer manually as shown angle in below, and then refit soudome.
Transducer
Soundome
.
Note 1: Do not lay the oil-filled soundome for five minutes. Oil may leak.
17
When the soundome is painted to keep marine life off the transducer, observe the following
precautions:
•
Use only anti-fouling paint type MARINE STAR 20 (Manufacture: Chugoku Marine Paint Co.,
Ltd., Japan).
•
Paint only the plastic portion of the dome. Painting the metal parts causes corrosion.
Paint area
19. Clean surface of gasket, tank flange and shaft sleeve, and then apply THREE BOND 1104
to flange gasket.
20. Apply a slight coat of KINORUSTER to bolts, nuts and washers.
21. Set the hull unit into the retraction tank, taking care not to damage soundome.
U-nut
Shaft retainer
Spring washer
Hex. bolt M10X35
Nut
Spring washer
Flat washer
Bow mark
Shaft sleeve
Flange gasket
Retraction tank
flange
Flat washer
Hex. bolt M20X80
18
22. Fix the shaft sleeve and retraction tank with hex bolts, flat washers and spring washers.
Hex bolt
Shaft retainer
15 mm
1-2 mm
Jubilee clip
Main shaft
Bow
10 mm
19
Checking manual raise/lower of soundome with hand crank
Perform this check after all wiring has been completed.
CAUTION
Turn the main power off before this check,
otherwise the raise/lower motor action may
cause injurely.
1. Turn off the breaker on the hull unit.
2. Detach the gear cover.
3. Set wrench (opposite side19 mm) to the screw shaft gear.
4. The transducer should rise/lower smoothly with even force in upper to lower limits. If not,
the centers of the shaft sleeve and the retraction tank are not aligned. Adjust the hull
mounting position if necessary. Check the following points.
•
•
•
Painting inside tank not smooth
Inner diameter of tank not uniform
Welding bead
20
1.4
Interface Unit
For the blackbox type, the interface unit is shipped as standard.
1.4.1
•
•
•
•
General mounting considerations
The mounting location should be well ventilated and dry, avoiding splay or rain.
The unit can be mounted on a bulkhead or the deck.
Secure the maintenance space shown in drawing below for ease of maintenance and
service.
The maximum cable length between the interface unit and the transceiver unit is 10 m.
External
monitor
Transceiver 06S4078
unit
A
06S4078
Interface
unit
B
External
monitor
Transceiver 06S4078 Interface
unit
unit
A+B<=15m
External
monitor
06S4078
A
1.4.2
Monitor unit
MU-100C
Interface
unit
A+C<=15m
C
Mounting method
Fasten the interface unit with four tapping screws (5X20, local supplied).
For bulkhead mounting, tighten upper tapping screws so there is 5 mm clearance between
bottom of screw head and bulkhead, and screw slots of the unit. Then fasten lower screws.
21
1.5
Motion Sensor MS-100 (option)
The MS-100 measures ship’s pitching and rolling angles with sensor using the principles of the
gyroscope. The MS-100 is free from error caused by ship’s vertical and horizontal motion.
Therefore, it can be installed at any convenient location. However, ship’s semi-permanent
inclination due to loading imbalance cannot be detected. Compensate for this as described in
Chapter 3.
1.5.1
•
•
•
Mounting considerations
Vibration in the mounting area should be minimal.
Locate the unit away from areas subject to water splash.
The ambient temperature should not exceed 50 °C
1.5.2
Mounting procedure
Orient the FORE mark on the unit toward the ship’s bow and mount the unit level to within 5° in
all direction. For the offset, see Chapter 3.
FORE
θ ≤ 5°
AFT
22
2. Wiring
2.1
•
•
•
Wiring among Units
The figure on the next page shows wiring among units.
The signal cables are fitted with connectors. Connect the cables to the display, transceiver
and hull units referring to the interconnection diagram and the drawing on page S-1.
The power cable should be arranged locally. Use power cable type DPYCYS-2.5 (Japan
Industrial Standard cable) or equivalent cables. Attach climp on lugs as shown below.
40
5
Vinyl sheath
Braided shield
Armor
FV2-4(blue)
50
Conductor
Insulator
Inclusion
Tape
Braided shield
Sheath
Armor
Vinyl sheath
S = 2.5 mm 2
=15.2 mm
•
•
The raise/lower drive motor and breaker are different depending on ship’s mains.
Install the main switch for the sonar where it can be easily accessed. Turn off this switch
when the sonar is not being used, to reduce power consumption and to prevent the
transducer from slipping by vibration.
•
If D-sub connector is too large to pass through the hole on the monitor, transducer and/or
interface unit, remove the connector cover.
23
Navigation Equipment
Note1
(5m)
06S4078
(5/10m)
*a
Interface
Unit
*b
HULL UNT
SPEAKER
Speaker
(w/cable)
Remote
Controler
MONITOR
Note 2
12-32VDC
DATA/VIDEO OUT
MOTION SENSOR
06S4037
(10m)
250V-DPYCYS-2.5
12-32VDC
Ext. KP
Motion Sensor
06S4080(15/30/50m)
06S4081
(3.5/5.2m)
12/24-32VDC
250V-DPYCYS-2.5
Note1:
Cable between the monitor unit and control unit
06S4079 (0.15m standard, for uni body type)
06S4085 (1.5m option, for separate type)
64S4063 (5m option, for separate type)
Note2:
A VGA monitor (local supply) can be added by
the connecting the optional interface unit.
Note3:
< 15m
*: a+b =
Wiring, with monitor
24
Interface unit
Note 1
Navigation Eauipment
15m
*a
*b
06S4078
(5/10m)
06S4078
(5/10m)
External monitor
Note 2
Interface unit
External monitor
64S4063(5m)
CONT
REM
Control unit, back view (5m)
HULL UNT
SPEAKER
Speaker
(w/cable)
Remote
Controler
12-32VDC
DATA/VIDEO OUT
Transceiver unit
MOTION SENSOR
06S4037
(10m)
Ext. KP
Motion senser
DPYCYS-2.5
12-32VDC
06S4080(15/30/50m)
06S4081
(3.5/5.2m)
12/24-32VDC
DPYCYS-2.5
Note1: Two interface units are connectable.
Note2: For blackbox type, the display monitor (local
supply) is reqired.
Note3: *a+b <
=15m
Wiring, no monitor
25
Hull unit
2.2
Transceiver Unit
Connect the cables as figure in below. Remove the cover of the power terminal board.
06P0240
J3
NH6P
CR12
J6
J1
+ -
J2
06P0241
*Note
SPEAKER
External speaker
SC-05WR
TRX
DATA/VIDEO OUT
Earth
Monitor unit MOTION SENSOR
Motion
sensor
MS-100
MU-100C
or
06S4080
Interface
unit
Hull
unit
External KP
IF-8000
CH-254/CH-255
*Note: Fix the braided shield with the clamp.
Transceiver unit, internal view
26
To ship's
earth
06P0242
TB1
*Note
12-32VDC
DPYCYS-2.5
Ship's mains
12/24/32 DCV
2.2.1 Synchronizing Transmission with Echo Sounder or Other
Sonar
To synchronize transmission of the CH-250 with an echo sounder or other type of sonar,
connect it as shown below.
NH6P (local supply)
Transceiver unit
Vinyl wire (local supply)
AWG22-26
J3
06P0240
Sonar, E/S
3 to 15V
possitive
KP OUT
+5V to 15V
GND
KPI 3
EXT_SW 5
GND 6
TRX clamp
Connection of transceiver unit to other sonar
Menu setting
1. Press the [MENU] key to display the user menu.
2. Operate the cursor pad to select COM1 at the top of menu display.
MENU
TX POWER
PULSELENGTH
TX RATE
INT REJECT
AGC
AUDIO LEVEL
COM1
COM2 HORZ VERT
ES
PRESET
SYS
MAX
LONG
10
OFF
OFF
0
REPLACE ONE OF ANY COLORS AMONG COLOR BAR WITH WHITE.(OFF)
: SELECT
: CHANGE
MENU: END
User menu (COMN)
3. Press the [] to select TX RATE.
4. Press the [] to display the setting window.
27
5
TX RATE
EXT. MIN
MAX
(EXT., 1-10)
TX rate setting window
5. Press the ["] to select EXTERNAL.
6. Press the [MENU] key to close the user menu.
Note: Outputting KP of CH-250 to other sonar, echo sounder
Transceiver unit
06P0240
J3
KPO
12V
positive
2
(E/S transmits, SONAR)
GND 6
CH-250 accepts positive KP with
amplitude of 0V to 12V.
Outputting KP of CH-250 to other sonar, echo sounder
g)
28
2.3
Hull Unit
Pass the cables to 06P0426 Board through the cable protectors.
Fasten glands securely
by hands.
J2
06P0246
J3
Cable from transducer
06S4081
J1
*Note
J1
J2
Cable from transceiver unit
06S4080
*Note
TB2
+
Power cable
250V-DPYCYS-2.5
-
*Note
Power Switch
Should always be in up (ON).
06P0243
Earth
Connect to ship's earth.
*Note: Fix the braided shield with cable clamp.
29
2.4
Interface Unit
DATA/VIDEO IN DATA/VIDEO OUT RGB OUT
Transceiver unit cable
06S4078
Monitor unit
cable
06S4078
CONT
NMEA
VGA
NAV
monitor Control
unit
cable
06S4079
Earth
Connect to ship's earth.
The blackbox type is required to connect a standard VGA monitor via the interface unit IF-8000.
Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male,
three rows of 15 pins) locally. The monitor used should satisfy the specifications shown below.
•
•
•
VGA type
ANALOG RGB 0.7 Vpp, positive polarity
TLL level H, V, Negative polarity
Note: Cut and remove the rubber covers as below to attach connectors to the interface unit..
Remove the
fixing metals.
Cut and remove
the covers.
Note: Connect control unit or navigator equipment to either interface unit or monitor unit
(supplied by FURUNO).
30
3. ADJUSTMENTS
3.1
General Checks
Table 3-1 General checks
Check point, Rating
Check Item
On-keel Installation
Retraction tank level
Off-keel Installation
Within 1 m
Clearance between transducer and
bottom of retraction tank when
transducer is completely retracted
by hand crank
1 cm
Transducer travel
(lowered by hand clank)
400 stroke:
Minimum 30 cm
Note: When checking, a clearance
of approximately 1 meter is required
under the bottom of the transducer.
Transducer heading
250 stroke:
Minimum 22 cm
Bow mark on the shaft sleeve should face
ship's bow.
31
Table 3-1 general checks (con’t)
Check Item
Check point, Rating
•
•
Wiring check
Rejecting source of noise and
interference
All lead wires are tightly fixed with contact
pins or crimp-on lugs.
All screws are firmly fastened.
Cables are firmly secured.
Cables shields are properly grounded.
Noise generating machinery (motor,
radiotelephone, TV set, etc.) are not placed
nearby.
•
Magnetic devices are not placed in the
vicinity of display unit.
Each unit is grounded with a copper strap.
Ship’s mains voltage
•
•
Watertightness
•
Earth
3.2
•
•
•
•
All cables are correctly connected.
Ship’s mains voltage is stable 12, 24 or 32
VDC.
Water should not leak from the main body
flange or along the main shaft.
TX Frequency Checking
Check the TX frequency after the installation.
1. Press the [MENU] key to open the user menu.
2. Press the cursor pad to select SYS at the top of the menu display.
MENU
COM1
COM2 HORZ VERT
GO TO SYS MENU
: SELECT
YES
: CHANGE
ES
NO
MENU: END
User menu (SYS)
3. Press the [] to select GO TO SYS MENU.
4. Press the [] to select YES to display the system menu.
32
SHORT-CUT
SYS
** SYSTEM MENU **
SYSTEM SETTING:
RANGE-SONAR MODE
RANGE-VERTICAL MODE
RANGE-E/S MODE
RANGE-TRACK MODE
COLOR PALETTE
LANGUAGE
SYSTEM BACKUP
LOAD BACKUP DATA
HEADING OFFSET, DRAFT OFFSET
ADJ MOTION SENSOR
TX FREQ ADJUST
TEST
TEST PATTERN
DEMO MODE
DEFAULT
: MENU DISPLAY MENU: END
: SELECT
System menu
5. Press the [] to select TEST.
6. Press the [] to show the test display.
MAIN PROGRAM NO. 0650110-**.**
PANEL PROGRAM NO. 0650104-0**
ROM
: OK
RAM
: OK
VRAM
: OK
NMEA
: OK
PANEL CPU
: OK
TX FREQUENCY
: 180 kHz
ROLL
: 10
PITCH
: 10
PULSES
NG
359
0
TRAIN
TEST COUNT= : 0
REMOTE CONTROL
PANEL
1
(LED)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 0 0
0
0
0 0 0
0
0
EXIT
0
0
0
0
0
0
0
** Program Version No.
Test display
7. Check the frequency at the TX FREQUENCY line on the test display.
8. Press the [MENU] key several times to close the menu.
33
3.3
Heading Alignment/Soundome Setting
Heading alignment
The heading line can be compensated through the system menu ( –30° to +30°).
1. Locate a target (buoy, etc.) in the bow direction and display it on the screen at close range,
read deviation. The heading alignment is correct when the target is displayed at 12 o’clock
on the screen.
Heading
12 o'clock position
Buoy
When on-screen target is skewed right,
transducer heading is skewed left.
Checking heading alignment
2. Press the [MENU] key to display the user menu.
3. Press the cursor pad to select SYS at the top of menu display.
MENU
COM1
COM2 HORZ VERT
GO TO SYS MENU
: SELECT
YES
: CHANGE
ES
NO
MENU: END
User menu (SYS)
4. Press the [] to select GO TO SYS.
5. Press the [] to select YES to display the system menu.
34
SHORT-CUT
SYS
** SYSTEM MENU **
SYSTEM SETTING:
RANGE-SONAR MODE
RANGE-VERTICAL MODE
RANGE-E/S MODE
RANGE-TRACK MODE
COLOR PALETTE
LANGUAGE
SYSTEM BACKUP
LOAD BACKUP DATA
HEADING OFFSET, DRAFT OFFSET
ADJ MOTION SENSOR
TX FREQ ADJUST
TEST
TEST PATTERN
DEMO MODE
DEFAULT
: SELECT
: MENU DISPLAY MENU: END
System menu
6. Press the [] to select HEADING OFFSET, DRAFT OFFSET, and then press the [] to
display the heading offset display.
** HEADING OFFSET/DRAFT OFFSET **
HEADING
:
0 ˚
(-180˚ - +180˚)
DRAFT
:
0.0 ˚
(0.0 - 60.0m)
: CHANGE
: SELECT
MENU: END
Head offset display
7. Press the [] [] to align heading (1 step) so that the target on heading direction appears
at the twelve o’clock position.
8. Press the [] to choose draft.
9. Press the [] [] to set ship’s draft.
10. Press the [MENU] key several times to close the menu.
11. Confirm that the target on heading direction appears at the twelve o’clock position.
Soundome setting Confirmation
Set the serial number for the soundome connected, under nine-999 or over 1000.
1.
Open the SYSTEM MENU following step 1 to 4 in the above.
2.
Select SYSTEM SETTING, and then press the [] to open the SYSTEM SETTING 1 menu.
35
** SYSTEM SETTING 1 **
MENU
1
2
: SHIP'S L/L SHIP'S LOP
: OFF
ON
POSITION
TRACK
CURRENT DATA
: OFF
HEADING INDICATION : TRUE
FLOW FROM
AZ
CURSOR L/L
FLOW TO
NORTH MARK
: OFF
ON
CSE DATA
NAV DATA
: NAV
: GPS
GYRO
LoranC LoranA DR DECCA OTHERS
TVG CORRECTION
: OFF
1/2
1/1
UNIT
: m
ft
fa
TEMP
:
TARGET L/L
: OFF
CUSTOM KEY
EMPHASIS MODE
ETA MARK
: PRESET KEY SHORT-CUT KEY
: OFF
NORMAL
RED
10sec 30sec 1min
: OFF
: SELECT
C
: CHANGE
HIRO P/B
F
ON
3min
6min
MENU: END
System setting 1 menu
3.
Press the cursor pad to select 2 and press the [] to show SYSTEM SETTING 2 menu.
** SYSTEM SETTING 2 **
MENU
: 1
2
STABILIZER
AUTO RETRACTION
: OFF
: OFF
ON
(OFF, 5-15 kt)
SPEED ALARM/MESSAGE : OFF
SWEEP INDICATOR
: DOT
ON
LINE
SOUNDOME SER. NO.
: ~999
1000~
DEFAULT SETTING
: NO
YES
MAXIMUM ALLOWABLE SPEED IS 15 KNOTS WHILE SOUNDOME IS BEING
RETRACTED. IF VESSEL HAS REPAID ACCELERATION CAPABILITIES,
AUTO RETRACTION SETTINGS OF 10-12 KNOTS ARE MANDATORY TO
AVOID CATASTROPHIC DAMAGE TO SOUNDOME ASSY. ANY PHISICAL
DAMAGE TO THE SOUDOME ASSY. IS CONSIDERED ABUSE AND
IS NOT A WARRANTY ISSUE.
: SELECT
: CHANGE
MENU: END
System setting 2 menu
4.
Confirm the soundome serial number at SOUNDOME SER. NO. If change, press [] to
select SOUNDOME SER. NO. and then press the [] to select ~999 or 1000~
appropriately.
5.
Press the [MENU] key several times to close the menu.
36
3.4
Adjustment of Motion Sensor
When the ship has a semi-permanent inclination, offset it as follows.
1. Press the [MENU] key to display the user menu.
2. Press the cursor pad to select SYS at the top of the menu display.
MENU
COM1
COM2 HORZ VERT
GO TO SYS MENU
: SELECT
YES
ES
SHORT-CUT
SYS
NO
MENU: END
: CHANGE
Display to select the system menu
3. Press the [] to select GO TO SYS.
4. Press the [] to select YES.
** SYSTEM MENU **
SYSTEM SETTING:
RANGE-SONAR MODE
RANGE-VERTICAL MODE
RANGE-E/S MODE
RANGE-TRACK MODE
COLOR PALETTE
LANGUAGE
SYSTEM BACKUP
LOAD BACKUP DATA
HEADING OFFSET, DRAFT OFFSET
ADJ MOTION SENSOR
TX FREQ ADJUST
TEST
TEST PATTERN
DEMO MODE
DEFAULT
: MENU DISPLAY MENU: END
: SELECT
System menu
5. Press the [] to select ADJ MOTION SENSOR, and then press the [] to display ADJ
MOTION SENSOR menu.
** ADJ MOTION SENSOR **
ROLL ANGLE:
0˚
ADJ: +5 ˚
(-10˚ - +10˚)
PITCH ANGLE: 0˚
ADJ: +5 ˚
(-10˚ - +10˚)
: SELECT
: CHANGE
MENU: END
Adj motion sensor menu
37
6. Press [] [] to select ROLL ANGLE or PITCH ANGLE.
7. Press [] [] to adjust (-10° to +10°).
By using a clinometer or other means, measure ship’s semi-permanent inclination angle. Take
the polarity of the angle as follows. For example, if the stern is 3° down, set -3°.
+
–
0
+
0
–
+
-
ROLL ANGLE
Starboard up
Starboard down
PITCH ANGLE
Stern up
Stern down
8. Press the [MENU] key several times to close the menu.
3.5 System Back Up
After setting the equipment follow the procedure below to back up system settings. Backup data
can be loaded in the event of equipment trouble, to restore previous system settings.
1. Press the [MENU] key to display the user menu.
2. Press the cursor pad to select SYS at the top of the menu.
MENU
COM1
COM2 HORZ VERT
GO TO SYS MENU
: SELECT
YES
: CHANGE
ES
SHORT-CUT
NO
MENU: END
Display to select the system menu
3. Press [] to select GO TO SYS MENU.
4. Press [] to select YES.
The system menu appears.
38
SYS
** SYSTEM MENU **
SYSTEM SETTING:
RANGE-SONAR MODE
RANGE-VERTICAL MODE
RANGE-E/S MODE
RANGE-TRACK MODE
COLOR PALETTE
LANGUAGE
SYSTEM BACKUP
LOAD BACKUP DATA
HEADING OFFSET, DRAFT OFFSET
ADJ MOTION SENSOR
TX FREQ ADJUST
TEST
TEST PATTERN
DEMO MODE
DEFAULT
: MENU DISPLAY MENU: END
: SELECT
System menu
5. Press [] to select SYSTEM BACKUP.
6. Press [] to display the system backup menu.
** SYSTEM BACK UP**
ARE YOU SURE?
:
NO
YES
NOTE: OVERWITES PREVIOUS BACKUP DATA
: CHANGE
MENU: END
System backup menu
7. Press [] to select YES.
8. Press the [MENU] key.
The backup data is loaded, and then return to the system menu.
9. Press the [MENU] key to return to the normal display.
39
3.6
Setting of Interface Unit
Set DIP switch S1 in the interface unit as follows.
•
The monitor unit MU-100C or the interface unit is connected to DATA/VIDEO OUT port of
the interface unit : all OFF.
•
Nothing is connected to DATA/VIDEO OUT port of the interface unit : all ON.
J6* J7*
BUFFER
J2
THROUGH
J1
S1
ON
J3
*: J6 and J7 set to "THROUGH" side.
Interface unit, DIP switch S1 location
External
Monitor
Processor
Unit
Interface
Unit
Monitor
Unit
S1:All OFF
External
Monitor
Processor
Unit
Interface
Unit
S1:All ON
Processor
Unit
External
Monitor
External
Monitor
Interface
Unit
Interface
Unit
S1:All OFF
S1:All ON
40
Input/Output Description
The CH-250 can receive/transmit the following sentences in NMEA 0183 format.
Input
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GLL:
GPS position
VTG:
Ground speed/true course
DBT:
Depth (Ignore talker, NMEA Ver1.5)
DBS:
Depth (Ignore talker)
DPT:
Depth (Ignore talker, NMEA Ver2.0)
GGA:
GPS position/Speed/Course (Ignore talker)
VDR:
Current direction/current speed (Ignore talker)
RMA:
Loran C position/LOP/Speed/Course
RMC:
GPS position/Speed/Course
VHW:
Water speed/Heading
HDG:
Heading
MTW:
Temperature
HDM:
Heading
HDA:
Temperature (Ignore talker)
HDT:
Heading
Output
•
TLL:
When entering event mark.
Priority (Input)
Own ship’s position
Course
Heading
Speed
Depth
Temperature
Current
GGA>RMC>RMA>GLL
RMC>RMA>VTG
HDG>VHW>HDM
RMC>RMA>VTG>VHW
DPT>DBT>DBS
MTW>MDA
VDR
41
LOP can be displayed only when RMA is inputted.
This page is intentionally left blank.
0#/'
#%%'5514+'5
#%%'5514+'5
52#4'2#465
70+6
+056#..#6+10/#6'4+#.5
176.+0'
0#/'
#%%'5514+'5
70+6
176.+0'
+056#..#6+10/#6'4+#.5
+056#..#6+10/#6'4+#.5
/,#52(
%2
/,#52(
%2
/:575
&2㩂㩥
41*5
:575
(2
%*
#5:
#5:
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
36;
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
#5: &'5%4+26+10%1&'ͳ
㪉㪅䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫ဳᑼ㪆䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
㪈㪅㩿㪁㪀ශ䈱䍗㪄䍪䍼䍷⚵ຠ䈲઀᭽䈮䉋䉍᳿ቯ䈘䉏䉁䈜䇯
㩿㪁㪀㩷㪤㪘㪩㪢㪜㪛㩷㪚㪘㪙㪣㪜㪪㩷㪘㪩㪜㩷㪪㪜㪣㪜㪚㪫㪘㪙㪣㪜㪅
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ/,
Ꮏ੐᧚ᢱ
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ/,
Ꮏ੐᧚ᢱ
&+52.#;%18'4
㩔㨺㩎㩨㩀㩔㩨㨺
*':$1.6
5.166'&9#5*'4*'#&
౐ⷺ㩇㩢㩦㩢㩈㩛㩇$
10641.70+6/1706+0)$#5'
ᠲ૞ขઃบ
%15/'6+%2.7)
㩘㨺㩣㩖㩩㩡㩂㩨
%10641.70+6$4#%-'6
㩉㨽㩅㩖㩨㩡㩃㨹㩎
5'.(6#22+0)5%4'9
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨‫ޓ‬㩆㨷
ઃዻຠ
%10641.70+6
ᠲ૞ㇱ
࡙࠾࠶࠻
%*%*
'
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
A-1
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
36;
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
/,#52(
%2
:575
/:%9/$%4㩕㩡
/:575
(2
(2
(2
()/$8#2$(
52
%*/7%
&'5%4+26+10%1&'ͳ
#5: ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
ᵈ⸥䋩㩷䍘䍎䍢䍼ᧃየ䈮㪲㪁㪁㪴䈱ઃ䈇䈢䍳䍤䍍䍢䈲ઍ⴫䈱ဳᑼ㪆䍘䍎䍢䍼䉕⴫␜䈚䈩䈇䉁䈜䇯
㪛㪦㪬㪙㪣㪜㩷㪘㪪㪫㪜㪩㪠㪪㪢㩷㪛㪜㪥㪦㪫㪜㪪㩷㪚㪦㪤㪤㪦㪥㪣㪰㩷㪬㪪㪜㪛㩷㪜㪨㪬㪠㪧㪤㪜㪥㪫㪅
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ/,
Ꮏ੐᧚ᢱ
5'.(6#22+0)5%4'9
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨‫ޓ‬㩆㨷
9#5*'4$+0&+0)*'#&5%4'9
㧗㩔㩨㨼㩧㩎㩨㩈㩛㩇(
*':$1.6
㨻㩖㩩㩈㨹㩎7+㩈㩛㩇$
$4#%-'6
㩔㩧㩀㩨㨺
/1706+0)$#5'
㩎㩢㩌㩃㩊㩨㨼
ઃዻຠ
*11&#55;
㩖㨺㩎㩨㩂㩚㩕㩧
ઃዻຠ
(75'
㩕㨷㨺㩇㩨
੍஻ຠ
%10641.&+52.#;70+6
ᠲ૞㧛⴫␜ㇱ
࡙࠾࠶࠻
%*%*
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
A-2
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
%4+/210.7)
࿶⌕┵ሶ
#5:
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%1&'01
(8㨻㨿
⇟ภ
01
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55;
㩃㨺㩖㩨㩣⚵ຠ
⇛‫ޓޓ‬࿑
176.+0'
%*5‫ޔ‬%*
ᢙ㊂
36;
#5:
ㆬᛯ‫ޓ‬61$'5'.'%6'&
ㆬᛯ‫ޓ‬61$'5'.'%6'&
ㆬᛯ‫ޓ‬61$'5'.'%6'&
ㆬᛯ‫ޓ‬61$'5'.'%6'&
ㆬᛯ‫ޓ‬61$'5'.'%6'&
↪ㅜ㧛஻⠨
4'/#4-5
#5: A-4
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%1&'01
5/
%1&'01
5/
%1&'01
5/
%1&'01
5/
%1&'01
5/
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%1&'01
6;2'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
ฬ‫ޓޓ‬⒓
0#/'
+056#..#6+10/#6'4+#.5
ฬ‫ޓޓ‬⒓
0#/'
ဳฬ㧛ⷙᩰ
&'5%4+26+105
+056#..#6+10/#6'4+#.5
⇟ภ
01
⇛‫ޓޓ‬࿑
176.+0'
#5: Ꮏ੐᧚ᢱ⴫
%2
6;2'
Ꮏ੐᧚ᢱ⴫
%1&'01
A-3
A-5
Y. Hatai
D-2
Y. Hatai
D-2A
Y. Hatai
D-5
D-8
D-8
Takahashi T.
Takahashi T.
D-13
Y. Hatai
CH-254/S 400mmストローク
400mm TRAVEL
CH-255/S 250mmストローク
250mm TRAVEL
旋回俯仰部 SOUNDOME
CH-2542/S
5B1 DOM 06P0244
VHR-3N
1
2
3
J1 XHP-12
TIP1 1
TIP3 2
TIP2 3
TIP4 4
TRP1 5
TRP3 6
TRP2 7
TRP4 8
TR0 9
+12V 10
GND 11
GND 12
J2
TD1
TD2
TD GND
B
送受信装置 TRANSCEIVER UNIT
CH-253
CH-2541/S
CH-2551/S
4B2 PRA 06P0246
VHR-3N J2 CN5
1 TD1
2 TD2
3 TD GND
VHR-4N
1
2
3
4
CN3 J3
SIGP+
SIGPNC
XHP-3
1
2
3
XH-20
HULL UNIT
TRX
*3
06S4080,φ13.7
15/30/50m
4B1 DRV 06P0243
SOUNDOME
*3
06S4081
3.5/5.2m
XHP-12 J2 CN4
1 TIP1
2 TIP3
3 TIP2
4 TIP4
5 TRP1
6 TRP3
7 TRP2
8 TRP4
9 TR0
10 +12V
11 GND
12 GND
CN1 J1 XH-20
PWRON-H 1
PWRON-C 2
RLCONT-H 3
RLCONT-C 4
TRM1-H 5
TRM1-C 6
TRM2-H 7
TRM2-C 8
TIM1-H 9
TIM1-C 10
TIM2-H 11
TIM2-C 12
HULLV-H 13
UPLMT-H 14
DNLMT-H 15
TR0-H 16
F0-H 17
TB2
1 (+)12/24-32VDC F1-H 18
2 (-)
F2-H 19
COM_C 20
*2
DPYCY-2.5
XH-6 J3 CN7
EXTERNAL 1 +12V
KP/SIG
2 KPO
3 KPI
4 SIG
5 EXT-SW
6 GND
CN1 J1
R 1
G 2
B 3
HS-N 4
VS-N 5
YC-N 6
TRXTD-A 7
CONTD-A 8
TD-A 9
RD-A 10
PSW-H 11
12VA 12
0V 13
R-GND 14
G-GND 15
B-GND 16
HS-N-GND 17
VS-N-GND 18
YC-N-GND 19
TRXTD-B 20
CONTD-B 21
TD-B 22
RD-B 23
PSW-C 24
12VA 25
DATA/VIDEO IN
XM2A-2501
*3
06S4078,φ12
5/10m
*2
DPYCY-2.5
TB1 3B3 PWR 06P0242
1 (+)12-32VDC
2 (-)
*2
DPYCY-1.5
1 2
5 6
(+)(-)
整流器
RECTIFIER
RU-1746B-2
注記
*1)オプション支給。
*2)現地手配。
*3)コネクタは工場で取付済み。
NOTE
*1. OPTION
*2. LOCAL SUPPLY
*3. CONNECTOR PLUG IS FITTED AT FACTORY.
J2 CN2
1 R
2 G
3 B
4 HS-N
5 VS-N
6 YC-N
7 TRXTD-A
8 CONTD-A
9 TD-A
10 RD-A
11 PSW-H
12 12VA
13 12VA-GND
14 R-GND
15 G-GND
16 B-GND
17 HS-N-GND
18 VS-N-GND
19 YC-N-GND
20 TRXTD-B
21 CONTD-B
22 TD-B
23 RD-B
24 PSW-C
25 12VA
CN1 J3
TRXTD-A 1
TRXTD-B 2
CONTD-A 3
CONTD-B 4
PSW-H 5
PSW-C 6
+12V 7
GND 8
SCAN-REV 9
F.GND 10
CONT
DISP
MJ-A10
MJ-A10
SPFD
SPFD
*3
MJ-A10SPF0002,φ9
06S4079 0.15m
06S4085 1.5m
64S4063 5m
2B1 PNL 06P0239
1
2
3
4
5
6
7
8
9
10
J1
TRXTD-A
TRXTD-B
CONTD-A
CONTD-B
PSW-H
PSW-C
+12V
GND
SCAN-REV
F.GND
CN3 J1
TD-A
TD-B
RD-A
RD-B
NC
F.GND
リモートコントローラ
REMOTE CONTROLLER *1
CH-256
NMEA
*3
MJ-A6SPFD
1
2
3
4
5
6
MJ-A6SPF0011-050C/100C
MJ-A6SPF0012-050C/100C
5/10m,φ6.0
航法装置
NAV. EQUIPMENT
IEC61162-1(NMEA)
*2
IV-2sq.
SPEAKER
100/110/115/
200/220/230VAC
1φ, 50/60 Hz
1B1 DISP 06P0238
3B2 TRX 06P0241
XHP-3 J6 CN6
1 SIGP+
2 SIGP3 NC
12/24-32 VDC
操作部 CONTROL UNIT
CH-252
VHR-4N J1 CN5
1 TR1
2 TR2
3 TD GND
4 NC
C
D
J1 CN4
1 PWRON-H
2 PWRON-C
3 RLCONT-H
4 RLCONT-C
5 TRM1-H
6 TRM1-C
7 TRM2-H
8 TRM2-C
9 TIM1-H
10 TIM1-C
11 TIM2-H
12 TIM2-C
13 HULLV-H
14 UPLMT-H
15 DNLMT-H
16 TR0-H
17 F0-H
18 F1-H
19 F2-H
20 COM_C
DATA/VIDEO OUT
XM2A-2501
S-1
6
表示部ユニット
DISPLAY UNIT
MU-100C
3B1 CPU 06P0240
CN2 J1
TR1
TR2
TD GND
NC
5
J2
REMS0-N
REMS1-N
REMR0-N
REMR1-N
REMR2-N
+12V
GND
A
上下動部
RAISE/LOWER DRIVE UNIT
4
1
2
3
4
5
6
7
上下装置
HULL UNIT
3
R/C
2
5m
1
CN2
スピーカ
SPEAKER
SC-05WR
5m
*1
MOTION
SENSOR
CN-3 J1 SRC-5P *3
12VB 1
ROLL 2
PITCH 3
GND 4
GND 5
S06-9-5
*1
延長ケーブル 5m
EXTENSION CABLE
*1
06S4037
φ9,10m
動揺検出器 *1
MOTION SENSOR
MS-100
または OR
傾斜角検出器
CLINOMETER *1
BS-704
*2
IV-2sq.
*2
IV-8sq.
DRAWN
CHECKED
E.MIYOSHI
TAKAHASHI.T
APPROVED
Y. Hatai
Mar.6,'06
SCALE
DWG. No.
TITLE
名称
相互結線図
MASS
NAME
kg
C1316-C01- D
CH-250/S
カラーLCDサーチライトソナー
REF. No.
COLOR SEARCHLIGHT SONAR
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
5B1 DOM 06P0244
VHR-3N
1
2
3
J1 XHP-12
TIP1 1
TIP3 2
TIP2 3
TIP4 4
TRP1 5
TRP3 6
TRP2 7
TRP4 8
TR0 9
+12V 10
GND 11
GND 12
J2
TD1
TD2
TD GND
B
SOUNDOME
*3
06S4081
3.5/5.2m
3B1 CPU 06P0240
CN2 J1
TR1
TR2
TD GND
NC
VHR-4N
1
2
3
4
CN3 J3
SIGP+
SIGPNC
XHP-3
1
2
3
XH-20
HULL UNIT
TRX
*3
06S4080,φ13.7
15/30/50m
4B1 DRV 06P0243
XHP-12 J2 CN4
1 TIP1
2 TIP3
3 TIP2
4 TIP4
5 TRP1
6 TRP3
7 TRP2
8 TRP4
9 TR0
10 +12V
11 GND
12 GND
CN1 J1 XH-20
PWRON-H 1
PWRON-C 2
RLCONT-H 3
RLCONT-C 4
TRM1-H 5
TRM1-C 6
TRM2-H 7
TRM2-C 8
TIM1-H 9
TIM1-C 10
TIM2-H 11
TIM2-C 12
HULLV-H 13
UPLMT-H 14
DNLMT-H 15
TR0-H 16
F0-H 17
TB2
1 (+)12/24-32VDC F1-H 18
2 (-)
F2-H 19
COM_C 20
*2
DPYCY-2.5
J1 CN4
1 PWRON-H
2 PWRON-C
3 RLCONT-H
4 RLCONT-C
5 TRM1-H
6 TRM1-C
7 TRM2-H
8 TRM2-C
9 TIM1-H
10 TIM1-C
11 TIM2-H
12 TIM2-C
13 HULLV-H
14 UPLMT-H
15 DNLMT-H
16 TR0-H
17 F0-H
18 F1-H
19 F2-H
20 COM_C
XH-6 J3 CN7
EXTERNAL 1 +12V
KP/SIG
2 KPO
3 KPI
4 SIG
5 EXT-SW
6 GND
CN1 J1
R 1
G 2
B 3
HS-N 4
VS-N 5
YC-N 6
TRXTD-A 7
CONTD-A 8
TD-A 9
RD-A 10
PSW-H 11
12VA 12
0V 13
R-GND 14
G-GND 15
B-GND 16
HS-N-GND 17
VS-N-GND 18
YC-N-GND 19
TRXTD-B 20
CONTD-B 21
TD-B 22
RD-B 23
PSW-C 24
12VA 25
DATA/VIDEO IN
XM2A-2501
DATA/VIDEO OUT
XM2A-2501
インターフェイス
ユニット
DATA/VIDEO
OUT
I/F UNIT
XM2A-2501 IF-8000 *1
XM2A-2501
DATA/VIDEO
IN
J1
J2
C
VHR-4N J1 CN5
1 TR1
2 TR2
3 TD GND
4 NC
J4
XHP-3 J6 CN6
1 SIGP+
2 SIGP3 NC
J2
XM2A-2501
*2
IV-2SQ.
スピーカ
SPEAKER
SC-05WR
5m
*1
100/110/115/
200/220/230VAC
1φ, 50/60 Hz
D
TB1 3B3 PWR 06P0242
1 (+)12-32VDC
2 (-)
*2
DPYCY-1.5
1 2
5 6
(+)(-)
MOTION
SENSOR
CN-3 J1 SRC-5P *3
12VB 1
ROLL 2
PITCH 3
GND 4
GND 5
S06-9-5
*1
延長ケーブル 5m
EXTENSION CABLE
整流器
RECTIFIER
RU-1746B-2
注記
*2
*1)オプション支給。
IV-8sq.
*2)現地手配。
*3)コネクタは工場で取付済み。
*4)送受信装置から表示部までのケーブル長の合計は15m以下であること。
*5)操作部と航法装置は表示部かインターフェイスユニットのどちらか一方のみに接続可能。
NOTE
*1. OPTION
*2. LOCAL SUPPLY
*3. CONNECTOR PLUG IS FITTED AT FACTORY.
*4. CABLE LENGTH BETWEEN TRANSCEIVER AND DISPLAY UNIT SHOULD BE 15 m OR LESS.
*5. CONNECT CONTROL UNIT AND NAV EQUIPMENT TO EITHER DISPLAY UNIT OR INTERFACE UNIT.
MJ-A6SPF0011-050C/100C
MJ-A6SPF0012-050C/100C
5/10m,φ6.0
J1
TRXTD-A
TRXTD-B
CONTD-A
CONTD-B
PSW-H
PSW-C
+12V
GND
SCAN-REV
F.GND
リモートコントローラ
REMOTE CONTROLLER *1
CH-256
MJ-A6SPF0011-050C/100C
MJ-A6SPF0012-050C/100C
5/10m,φ6.0
航法装置 *5
NAV. EQUIPMENT
IEC61162-1(NMEA)
航法装置 *5
NAV. EQUIPMENT
IEC61162-1(NMEA)
*4 *3 *1
06S4078
5m,φ12
インターフェイス
ユニット
I/F UNIT
XM2A-2501 IF-8000 *1
DATA/VIDEO
IN
J1
RGB OUT
Dsub-15P
J3
CONT
MJ-A10SPFD
動揺検出器 *1
MOTION SENSOR
MS-100
または OR
傾斜角検出器
CLINOMETER *1
BS-704
1
2
3
4
5
6
7
8
9
10
NMEA
*3
MJ-A6SPFD
J4
*1
06S4037
φ9,10m
2B1 PNL 06P0239
*2
NMEA
MJ-A6SPFD
J5
DISP
CONT
MJ-A10
MJ-A10
SPFD *3
SPFD
MJ-A10SPF0002,φ9
06S4079 0.15m
06S4085 1.5m
64S4063 5m
外部モニター IV-2sq.
EXT. VGA MONITOR
*5
操作部
リモートコントローラ
CONTROL UNIT
REMOTE CONTROLLER
CH-252
CH-256
CONT
MJ-A10SPFD
CN2
*2
DPYCY-2.5
CN1 J3
J2 CN2
1 R
TRXTD-A 1
2 G
TRXTD-B 2
3 B
CONTD-A 3
4 HS-N
CONTD-B 4
5 VS-N
PSW-H 5
6 YC-N
PSW-C 6
7 TRXTD-A
+12V 7
8 CONTD-A
GND 8
9 TD-A
SCAN-REV 9
10 RD-A
F.GND 10
11 PSW-H
12 12VA
13 12VA-GND
14 R-GND
15 G-GND
16 B-GND
17 HS-N-GND
18 VS-N-GND
19 YC-N-GND
CN3 J1
20 TRXTD-B
TD-A 1
21 CONTD-B
TD-B 2
22 TD-B
RD-A 3
23 RD-B
RD-B 4
24 PSW-C
NC 5
25 12VA
F.GND 6
J3
SPEAKER
12/24-32 VDC
1B1 DISP 06P0238
RGB OUT
Dsub-15P
3B2 TRX 06P0241
操作部 CONTROL UNIT
CH-252 *5
J2
REMS0-N
REMS1-N
REMR0-N
REMR1-N
REMR2-N
+12V
GND
旋回俯仰部 SOUNDOME
CH-2542/S
表示部
DISPLAY UNIT
MU-100C
1
2
3
4
5
6
7
VHR-3N J2 CN5
1 TD1
2 TD2
3 TD GND
TRANSCEIVER UNIT
R/C
4B2 PRA 06P0246
S-2
6
5m
CH-254/S 400mmストローク
400mm TRAVEL
CH-255/S 250mmストローク
250mm TRAVEL
送受信装置
CH-253
CH-2541/S
CH-2551/S
5
*3 *4
06S4078,φ12
5/10m
A
上下動部
RAISE/LOWER DRIVE UNIT
4
SELECT
上下装置
HULL UNIT
3
選択
2
*3 *4
06S4078,φ12
5/10m
1
NMEA
MJ-A6SPFD
J5
外部モニターNo.2
EXT. VGA MONITOR No.2
操作部 *5
リモートコントローラ
REMOTE CONTROLLER
CONTROL UNIT
CH-256
CH-252
MJ-A6SPF0011-050C/100C
MJ-A6SPF0012-050C/100C
5/10m,φ6.0
航法装置 *5
NAV. EQUIPMENT
IEC61162-1(NMEA)
*2
IV-2sq.
*2
IV-2sq.
DRAWN
CHECKED
E.MIYOSHI
TAKAHASHI.T
APPROVED
Y. Hatai
Mar.6,'06
SCALE
DWG No.
TITLE
名称
相互結線図
MASS
NAME
kg
C1316-C02- D
CH-250/S
カラーLCDサーチライトソナー(I/Fユニット使用)
REF. No.
COLOR SEARCHLIGHT SONAR (W/ I/F UNIT)
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.