Intrusion Systems | ISM‑BLA1‑LM Blue Line Nightlight Module
ISM‑BLA1‑LM Blue Line Nightlight Module
▶ Modular construction fits all Blue Line detectors
▶ High quality, affordable, and easy to install
▶ Exterior switches control light duration (short or
long) and on or off
▶ Two installer-selectable brightness levels
▶ Aesthetic design
The Blue Line ISM-BLA1-LM Nightlight Module attaches to
the Blue Line detectors. When the detector senses a
presence, the module's LEDs light and provide
illumination up to the equivalent of bright moonlight
(0.1 cd at 30 cm [1 ft] from the detector).
The length of time the LEDs remain lit is set with an
external switch on the side of the module. Short duration
is approximately 20 sec to 30 sec; while long duration is
approximately 2 min to 4 min.
On-Off
Functions
Use the external On or Off switch on the side of the
module to determine if the LEDs light when motion is
detected.
Unique Interface
Field Testing
The Blue Line Nightlight Module mounts on top of and is
wired to a Blue Line detector. This unique interface
between module and detector makes installation fast,
easy, and inexpensive. Once the detector is mounted and
wired to the control panel, you simply add the module
with no additional wiring needed.
The module comes with a piece of black plastic for
covering the photo-sensor for field testing the module.
Basic Operation
The nightlight module has a photo-sensor and four LEDs
under a diffusing lens. It mounts on, draws its power
from, and is controlled by any Blue Line detector. Once
installed and set, if the detector senses motion and the
photo-sensor does not detect light, the LEDs light.
Settings
Brightness
The brightness level can be set for low or high by
positioning a jumper during module installation.
Duration
www.boschsecurity.com
2 | ISM‑BLA1‑LM Blue Line Nightlight Module
Certifications and Approvals
Region
Certification
Europe
CE
Russia
USA
Parts Included
89/336/EEC, EN50130-4: 1996 +A1:
1998 +A2: 2003, EN61000-4-2: 1995
+A1: 1998 +A2: 2001, EN61000-4-3:
2002 +A1: 2002 +A2: 2005,
EN61000-4-4: 1995 +A1: 2000 +A2:
2001, EN61000-4-5: 1995 +A1: 2001,
EN61000-4-6: 1996 +A1: 2001 +A2:
2001 +A3: 2005, EN61000-4-11:1994
+A1: 2001
GOST
GOST 12997-84, GOST R 50009-2000,
GOST R 51317.3.2-99, GOST R
51317.3.3-99, GOST R MEK
60065-2002
Component
1
Nightlight module
1
Test filter
1
Literature pack
Technical Specifications
Environmental Considerations
Complies with EN50131 Environmental Class II, Security Grade 2
Relative Humidity:
Up to 95% non-condensing
Up to 85% for UL installations
Temperature (operating):
-10°C to +49°C (+14°F to +120°F)
For UL Listed product installations,
0°C to +49°C (+32°F to +120°F)
ANSR: Intrusion Detection Units (UL639),
ANSR7: Intrusion Detection Units
Certified for Canada (cULus)
Mechanical Properties
B-509-0009/a
Color:
White
Dimensions:
2.5 cm x 6.4 cm x 3.2 cm
(1.0 in. X 2.5 in. X 1.25 in.)
Installation/Configuration Notes
Material:
High-impact ABS plastic
Compatibility Information
Output
The BLA1-LM Nightlight Module is compatible with the
following products:
Light Intensity:
Belgium
Detectors
UL
Quant.
INCERT
0.1 cd at 30 cm (1 ft)
Power Requirements
BLD1
Blue Line TriTech® Detectors
BLD1-P
Blue Line Pet Friendly® TriTech® Detectors
Current Draw
(LEDs lit):
Brightness level set low: 40 mA
Brightness level set high: 75 mA
BLP1
Blue Line PIR Detector
Standby Power:
BLP1-P
Blue Line Pet Friendly® PIR Detector
BLQ1
Blue Line quad PIR Detector
No internal standby battery. Standby power must be
provided by the control unit or by a UL Listed burglary power supply.
Mounting Considerations
The nightlight module mounts on top of a Blue Line
detector by removing the detector from its mounting
base, installing the module on the detector base, and
reattaching the detector and the module lens. Ensure
there is enough space above the detector for the
nightlight module.
Ordering Information
ISM‑BLA1‑LM Blue Line Nightlight Module
Fits all Blue Line detectors
Wiring Considerations
The three module wires attach to the terminal block of the
Blue Line detector.
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
[email protected]
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
[email protected]
www.boschsecurity.com
© Bosch Security Systems Inc. 2010 | Data subject to change without notice
T1642545163 | Cur: en-US, V12, 2 Dec 2010
Asia-Pacific:
Represented by
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6258 5511
Fax: +65 6571 2698
[email protected]
www.boschsecurity.com
ISM-BLA1-LM